• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 133
  • 1
  • Tagged with
  • 134
  • 134
  • 134
  • 82
  • 67
  • 67
  • 47
  • 47
  • 36
  • 30
  • 28
  • 26
  • 26
  • 26
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Diagnóstico de faltas em sistemas de subtransmissão : uma formulação baseada na Transformada Wavelet contínua

Iurinic, Leonardo Ulises January 2012 (has links)
As faltas podem ocorrer em diversos componentes de um sistema elétrico de potência, dentre os quais as linhas de transmissão se destacam como elementos susceptíveis. Devido a suas dimensões físicas, ambiente de operação e interconexão com outros sistemas, a localização exata de uma falta em uma linha de transmissão não é trivial dificultando a tarefa das equipes de manutenção para recomposição do fornecimento de energia. Neste contexto, este trabalho apresenta uma metodologia computacional desenvolvida em ambiente MATLAB® para diagnóstico de faltas em linhas de transmissão baseada na análise de transitórios de alta freqüência nas tensões do sistema. A abordagem desenvolvida neste trabalho inicialmente utiliza a equação de Park para achar a tensão zero, direta e em quadratura e posteriormente detectar a ocorrência da falta através do coeficiente de diferenças. Posteriormente, a teoria de ondas viajantes associada à transformada wavelet contínua são utilizadas objetivando determinar a frequência característica do sinal transitório, a qual é relacionada com o local da falta. Para validar o algoritmo de localização proposto foram realizadas diversas simulações de faltas com o programa ATP (Alternative Transient Program) utilizando dados de uma linha aérea real. A efetividade da abordagem proposta foi avaliada considerando a resistência de falta, o ângulo de incidência da falta e a impedância de curto-circuito do sistema. Os resultados promissores demonstraram a aplicabilidade da formulação proposta para localização faltas em linhas de transmissão aéreas utilizando medições oscilográficas digitais de apenas um terminal. / Faults can occur in several components of an electric power system, among which the transmission line stands out. Due to its physical dimensions, operating environment and interconnection systems, the exact transmission line fault location is non-trivial hindering maintenance crew system restoration. In this context, this work presents a computational methodology developed in MATLAB® environment for fault diagnosis on transmission lines based on voltage high frequency transient analysis. Thus, the approach adopted in this work use firstly the Park equations to find the zero, direct and quadrature voltage and then detect the fault occurrence through the difference coefficient. After, the traveling wave theory associated with continuous wavelet transform application is used for determining the characteristic frequency of the transient signal, which is correlated with the fault location. To validate the proposed fault location algorithm, several fault simulations were executed using ATP software using real overhead line data. The proposed fault location scheme performance was evaluated considering the fault resistance, inception fault angle and short-circuit impedance of the system. The promising results demonstrate the applicability of the proposed formulation for fault location in overhead transmission lines, using one terminal digital oscillographic measurement.
112

Localização de defeitos em alimentadores primários subterrâneos : formulação estendida baseada na impedância aparente

Filomena, André Darós January 2008 (has links)
O presente trabalho apresenta uma abordagem estendida para o diagnóstico de faltas em sistemas subterrâneos de distribuição de energia. O esquema proposto desenvolve modificações às técnicas de localização de defeitos em sistemas de distribuição aéreos baseadas no cálculo da impedância aparente, adaptando-as para a aplicação em alimentadores primários de topologia subterrânea. Sistemas subterrâneos estão associados à alta confiabilidade, com índices reduzidos de interrupção devido a suas características construtivas, que impedem a ocorrência de perturbações devido a fenômenos climáticos, mecânicos ou humanos. No entanto, as falhas em cabos subterrâneos são tipicamente permanentes, exigindo a substituição da seção de linha defeituosa para o restabelecimento do sistema. De forma distinta às redes aéreas, onde a localização de defeitos pode ser realizada por meio de inspeções visuais, a topologia subterrânea impossibilita a utilização desta abordagem. Embora o processo de digitalização dos esquemas de proteção de alimentadores primários tenha incentivado o desenvolvimento de inúmeras metodologias para a localização de defeitos em redes de distribuição aéreas, características típicas de redes de distribuição subterrâneas não foram contempladas. Nestes sistemas, a aplicação das técnicas desenvolvidas para sistemas aéreos resulta em estimativas errôneas da distância da falta. O esquema proposto visa a superar esta deficiência dos algoritmos de localização tradicionais, adaptando-os às características típicas de redes de distribuição subterrâneas. A formulação desenvolvida se baseia no cálculo da impedância aparente, o qual poderá ser incorporado como sub-rotina de relés de proteção de arquitetura digital. Além de disponibilizar a estimativa da distância da falta, o esquema de localização de defeitos proposto obtém uma estimativa das resistências de falta associadas à perturbação. A metodologia utiliza como dados de entrada os sinais de tensão e corrente referentes aos períodos de pré-falta e durante a perturbação, e propõe uma compensação da componente capacitiva, característica típica e não-desprezível de cabos subterrâneos. De modo a contemplar a existência de ramificações laterais, o esquema de localização propõe a utilização de sistemas radiais equivalentes, determinados a partir de rotinas de fluxo de potência trifásico. Tendo em vista o comportamento randômico do carregamento em sistemas de distribuição, a metodologia propõe, ainda, uma análise do perfil de carga durante o período pré-falta. Para possibilitar uma análise da eficiência do método proposto, testes comparativos com uma técnica de localização de defeitos para redes de distribuição de topologia aérea recentemente proposta foram realizados. De modo a validar o esquema de localização de defeitos proposto, foram executadas inúmeras simulações computacionais a partir de dados reais de um alimentador subterrâneo. O desempenho do esquema de diagnóstico de faltas foi avaliado frente aos aspectos de: resistência de falta, distância da falta, ângulo de incidência de falta, existência de cargas desequilibradas e variações no carregamento do sistema. Os resultados obtidos demonstram a viabilidade da aplicação da metodologia proposta para a localização de defeitos em sistemas de distribuição subterrâneos. / This work presents an extended approach for underground power distribution system fault location. The scheme develops modifications in the proposed impedance-based fault location techniques for overhead distribution systems, adapting it for underground feeders. Under-ground systems are associated to high reliability, with low interruption rates due to its con-struction characteristics, which avoid the fault occurrence from climatic, mechanics or human interference. However, the underground cables damages are typically permanent, requesting the damaged line section substitution before system restoration. Fault location on overhead systems can be assisted by visual inspection, on underground system, this approach can not used. Although the primary feeder protection scheme's digitalization process has stimulated the development of several fault location schemes for overhead feeders, typical underground's system characteristics were not considered. In these systems, the application of the techniques used on overhead systems results in erroneous fault distance estimates. The proposed methodology aims to overcome this limitation of traditional fault location algorithms, adapting it to the typical underground systems characteristics. The proposed formulation is based on the apparent impedance calculation, and can be included as a sub-routine in digital protection relays. Besides the fault distance estimates, the fault diagnosis scheme also calculates the fault resistances associated to each disturbance. The fault location scheme uses as input data the voltage's and current's signals before and during the fault, and also proposes a capacitive current compensation. The fault location technique also proposes the usage of equivalent radial systems, calculated through three-phase load flow techniques, to allow the algorithm coverage on laterals and sub-laterals. Due to the random load profile of distribution systems, the technique develops a load profile analysis during the pre-fault period. In order to provide efficiency analysis of the proposed formulation, comparative testes with a recently proposed fault location technique was realized. To validate the proposed fault location algorithm, several fault simulations were executed using real underground feeder data. The proposed fault location scheme performance was evaluated considering the following aspects: fault resistance, fault distance and inception fault angle. Also, the methodology was analyzed considering different load profiles, including unbalanced loads and load variation. The obtained results demonstrate the applicability of the proposed formulation for fault location in underground distribution systems.
113

Alocação de dispositivos de proteção e manobras para otimização da confiabilidade de sistemas elátricos de distribuição de energia com restrições de restabelecimento

Campo, Sergio Daniel Martinez January 2014 (has links)
Uma das principais metas das empresas concessionárias é fornecer energia a seus clientes de forma continua, confiável e com baixo custo. A qualidade do serviço de distribuição de energia é fiscalizada por órgãos reguladores do setor elétrico, sendo quantificada por métricas como o indicador de confiabilidade SAIDI (System Average Interruption Duration Index). A melhoria da confiabilidade dos sistemas de distribuição de energia elétrica é um assunto em destaque atualmente, tendo em vista a necessidade de um suprimento de energia cada vez mais confiável, para evitar as perdas econômicas que ocorrem com as interrupções. Neste contexto, este trabalho apresenta uma contribuição para a solução do problema de restabelecimento de sistemas de distribuição. A abordagem consiste no desenvolvimento de um modelo analítico de otimização, cujo objetivo principal é determinar a localização das chaves de manobras na rede que possibilite o restabelecimento efetivo da carga no período pós-falta. A viabilidade do restabelecimento é considerada através de restrições que garantem níveis adequados das tensões nas cargas, bem como a limitação da sobrecarga das linhas e as capacidades de reserva dos alimentadores adjacentes. A modelagem destas restrições é efetuada através de uma versão linear do fluxo de potência em termos das injeções nodais de correntes. As equações que descrevem o fluxo de potência são formuladas como funções das localizações das chaves de manobras no alimentador. A confiabilidade é caracterizada em termos da duração média das interrupções sustentadas, mensurada pelo indicador SAIDI. Visando à maior precisão na representação do efeito das faltas sobre a confiabilidade do alimentador, a metodologia agrega um modelo existente na literatura para alocação dos dispositivos de proteção de forma simultânea às chaves de manobras. A alocação dos dispositivos de proteção e manobras é sujeita a restrições técnicas e econômicas. Para resolver o modelo de otimização não-linear inteira mista, é usada uma técnica de otimização de uso geral, baseada no algoritmo Branch-and-Bound. Assim, metodologia permite a otimização determinística da confiabilidade do alimentador, garantindo o nível ótimo de confiabilidade e a racionalização dos investimentos por parte das concessionárias. Um estudo de caso é apresentado para avaliar a efetividade da metodologia na otimização da confiabilidade de um alimentador de distribuição real. / One of the main goals of utility companies is to provide energy to its customers continuously, reliably and cost effectively. The quality of power distribution service is supervised by regulators of the electricity sector, being quantified by metrics such as the reliability index SAIDI (System Average Interruption Duration Index). Improving the reliability of electricity distribution systems is a key issue nowadays, in view of the need for an increasingly reliable power supply in order to avoid the economic losses due to interruptions. In this context, this work presents a contribution to solve the distribution systems restoration problem. An analytical model is developed to determine locations of the sectionalizing switches in order to restore the system loads in the post-fault period. Restoration feasibility is considered by constraints that ensure adequate voltage levels on the system loads, emergency capacity of support feeders as well as line overloads. Constraints modeling is performed by a linear power flow based on current injection approach. Power flow equations are formulated as functions of switches locations. Reliability is considered in terms of average interruption durations measured by the SAIDI index. Aiming to a greater precision in representing the reliability impact of faults, the methodology aggregates a model from the literature for simultaneous allocation of protective devices and switches. Protective devices and switches allocation is subject to technical and economical constraints. The proposed model is solved by a general-use optimization technique, based on the branch-and-bound method. The proposed methodology makes possible the deterministic optimization of distribution reliability, as well as to rationalize investments of electric utilities. A case study is presented to evaluate the effectiveness of reliability optimization of a real distribution feeder.
114

Análise da estabilidade de sistema elétrico de potência com inserção de fontes renováveis

Walantus, Lucas Alejandro January 2014 (has links)
Nesta dissertação apresenta-se um estudo sobre o desempenho dinâmico do sistema elétrico de potência, frente à conexão de um parque eólico ligado através de conversores de frequência e de geradores síncronos de fontes hidrelétricas e termoelétricas. Dependendo da forma com que é gerenciado, este tipo de geração pode causar impactos significativos no sistema de energia elétrica. Este trabalho analisa o comportamento da estabilidade transitória nos sistemas de potência do ponto de vista da geração com inserção de fontes renováveis. Um sistema elétrico é proposto com dados reais do Rio Grande do Sul e modelado nos programas ANAREDE e ANATEM, considerando seus principais componentes, entre eles, linhas de transmissão, cargas, geradores e transformadores. São utilizadas estratégias de controle do programa ANATEM para a operação dos mesmos e estudar o comportamento do sistema elétrico de potência frente a diferentes eventos. Simulações são realizadas para investigar a influência de diversos fatores na resposta transitória do sistema. Os fatores analisados são: tempo de eliminação da falta, carregamento do sistema, níveis de geração das fontes tradicionais e das fontes eólicas. A análise dos resultados mostrara o impacto deste tipo de fontes instaladas no sistema em regime permanente e transitório. / This thesis introduces a study of an electric power system’s dynamic performance with traditional generation sources (hydro and thermoelectric) and wind farms. Depending on how it is managed, significant impact in the electric power system may occur. The power system transient stability is analyzed in this thesis considering the insertion of renewable energy resources. An equivalent power system is proposed with real data of Rio Grande do Sul and modeled using ANAREDE and ANATEM software, including as its main components, transmission lines, loads, generators and transformers. The control strategies present in the software ANATEM are used for the operation of these components, and then, to study the behavior of the electric power system against different events. Simulations are performed to investigate the influence of various factors on the transient response of the system. The factors analyzed are: time of fault clearing, system load, generation levels from traditional sources and wind sources. The analysis of the results shows the impacts of these specific resources in the system performance for steady state operation and transient state.
115

Uma proposta de relé digital de freqüência baseado em algoritmos genéticos / A proposal of a digital frequency relay based on genetic algorithms

Elis Tápia Vargas 10 October 2005 (has links)
Este trabalho apresenta um método baseado em algoritmos genéticos – AGs, o qual consiste na estimação dos parâmetros associados as formas de ondas, tais como amplitude, freqüência e ângulo de fase das mesmas, referentes a uma proposição de relé de freqüência. O método proposto é baseado em algoritmos genéticos com representação real, tendo em vista a não necessidade de codificação dos valores logo na entrada do processo. O objetivo do trabalho é apresentar um estudo de uma das várias técnicas da computação evolutiva, conhecida como AG, cuja aplicação é inspirada nos mecanismos da evolução natural das espécies identificado pelo naturalista inglês Charles Darwin. A idéia principal do método é fazer com que os indivíduos da população evoluam ao longo das iterações, chamadas gerações, produzindo soluções cada vez melhores até convergir a uma solução ótima ou aproximadamente ótima. O algoritmo proposto foi testado com dados simulados no software Matlab. Pelos resultados observados têm-se caracterizado a potencialidade desta ferramenta computacional na estimação dos parâmetros desejados. / This work presents a method based on genetic algorithm – GAs, which consists on estimation of parameters in waveforms, such as their amplitude, frequency and phase angles, related to the application of a frequency relay. The proposed study is based on the genetic algorithms with real representation, once there is no need to codify the values on the input of the process. The objective of this work is to present one of the several techniques of artificial intelligence, known as genetic algorithm, in which the main application is inspired in mechanisms of natural evolution of the species identified by Charles Darwin. The main idea of this method is to make the individuals from one population, called generation, to evolute, producing better solutions until they converge to an optimal or approximately optimal solution. The proposed algorithm was tested with simulated data from Matlab software. The results observed have characterized the efficiency of this computational tool for the estimation of the desired parameters.
116

Proposta de um sistema híbrido composto por redes neurais artificiais e algorítmos genéticos para o tratamento de alarmes e o diagnóstico de faltas em sistemas elétricos de potência / Proposal of a hybrid system composed of artificial neural networks and genetic algorithms for the treatment of alarms, and fault diagnosis in electrical power system

Toller, Marcelo Brondani 18 February 2011 (has links)
This work proposes a hybrid system for alarm processing and fault diagnosis in electrical networks which use two methods of computational intelligence: Generalized Regression Neural Network and Genetic Algorithms. The neural network has the function of processing the set of received alarms and present as a response the characteristic(s) event(s), using for this, an elaborated knowledge based on the functional diagrams for protection and interviews with operators. Six modules were implemented for different neural components of a test system, according to their protection schemes. The output of these modules is used as input to the GA which has to do a combined analysis along with its database and provide the operator with the main protective components involved in the incident, as well as the probable causes of defects and actions to be taken in order to return the system in the shortest possible time and greater safety. For average inserted random errors of 0%, 7,73%, 15,46% and 23,19% in the received alarms, the system was able to diagnoses correctly in 100%, 93,60%, 74,26% and 48,07% of the cases respectively. It was found that the genetic algorithm improved the results obtained by neural network with good capability of generalization and condition to present multiple solutions, and the response time of the hybrid system was acceptable to the under consideration problem. / O presente trabalho propõe um sistema híbrido para processamento de alarmes e diagnóstico de faltas em redes elétricas com a utilização de dois métodos de inteligência computacional: Generalized Regression Neural Network e Algoritmos Genéticos. A rede neural tem a função de processar o conjunto de alarmes reportados e apresentar como resposta o evento(s) característico(s), utilizando-se, para isso, de um conhecimento elaborado com base nos diagramas funcionais da proteção e entrevista com operadores. Foram implementados seis módulos neurais para diferentes componentes de um sistema teste, de acordo com os seus respectivos esquemas de proteção. A saída destes módulos é utilizada como entrada para o AG que deve fazer uma análise combinatória juntamente com sua base de dados e apresentar ao operador os principais componentes de proteção envolvidos na incidência, bem como as prováveis causas do defeito e ações a serem tomadas de forma a restabelecer o sistema no menor tempo possível e com maior segurança. Para erros aleatórios médios inseridos de 0%, 7,73%, 15,46% e 23,19% nos alarmes reportados, o sistema se mostrou capaz de diagnosticar corretamente em respectivamente 100%, 93,60%, 74,26% e 48,07% dos casos. Verificou-se que o algoritmo genético melhorou os resultados obtidos pela rede neural, apresentando boa capacidade de generalização e condições de apresentação de múltiplas soluções, sendo o tempo de resposta do sistema híbrido aceitável para o problema tratado.
117

Metodologia para coordenação otimizada entre relés de distância e direcionais de sobrecorrente em sistemas de transmissão de energia elétrica / Methodology for optimized coordination of distance and directional overcurrent relays in electrical transmission systems

Moro, Vinícius de Cillo 05 September 2014 (has links)
A proteção de sistemas de energia elétrica possui papel extremamente importante no aspecto de garantir o fornecimento de energia de maneira segura e confiável. Assim, a ação indevida ou a não atuação deste sistema de proteção pode causar danos materiais ou econômicos tanto para as concessionárias quanto para os consumidores de energia elétrica. Dessa forma, o sistema de proteção deve estar bem ajustado para que possa garantir suas funções, sendo sensível, seletivo, confiável e rápido. Para tanto, uma boa coordenação entre os relés de proteção deve ser estabelecida. No caso de um sistema de transmissão, o qual costuma ser um sistema malhado, a proteção é comumente realizada por relés de distância aliados a relés de sobrecorrente com unidade direcional, sendo que estes funcionam como elemento de retaguarda daqueles. O processo de ajuste desses relés é um trabalho muito difícil e demorado, que pode ainda estar sujeito a erros do engenheiro de proteção responsável pelo estudo. Neste contexto, este trabalho tem como objetivo desenvolver uma metodologia baseada na otimização por enxame de partículas que obtenha automaticamente os ajustes desses relés de forma a garantir a coordenação e seletividade entre eles, tornando assim o processo de ajuste mais rápido e preciso. Dessa forma, essa metodologia pode constituir uma ferramenta de auxílio muito favorável ao engenheiro de proteção. Além disso, como em todo problema de otimização, a função objetivo e as restrições foram definidas de maneira a retratar o problema de coordenação envolvendo tanto os relés de distância quanto os direcionais de sobrecorrente. A metodologia foi aplicada a dois sistemas, um fictício com 16 relés e um sistema de transmissão real com 44 relés, sendo que em ambos os casos ela apresentou resultados bastante satisfatórios proporcionando ajustes bem coordenados. / Electrical power systems protection has a very important role in the aspect of ensuring energy supply with safety and reliability. Thus, improper action or non-actuation of this protection system can cause materials and/or economics damages to electricity utilities as well as ordinary energy consumers. Therefore the protection system must be well adjusted so it can ensure its functions and thus being sensible, selective, reliable and fast. In order to achieve these characteristics, the protective relays must be well coordinated. In the case of meshed transmission systems, the protection is generally performed by distance relays as primary protection associated with directional overcurrent relays as backup protection. The process of adjusting these relays is very tough, slow and it can even be subject to the protection engineer mistakes. In this context, this work aims to develop a particle swarm optimization based methodology that can automatically obtain these relays adjusts so they can ensure relays coordination and selectivity, and then make this setting process faster and more precise. Thus, this methodology may provide a very favorable tool to aid the protection engineer. Moreover, as in any optimization problem, the objective function and the constraints were defined to represent the coordination problem involving both distance and directional overcurrent relays. The methodology was applied to two systems, a fictitious with 16 relays and a real transmission system with 44 relays, and in both cases it showed satisfactory results providing well-coordinated settings.
118

Sistema híbrido inteligente para o monitoramento e proteção de transformadores de potência / Hybrid intelligent system for monitoring and protection of power transformers

Barbosa, Daniel 15 October 2010 (has links)
Este trabalho apresenta um conjunto de métodos para a proteção e o monitoramento de transformadores de potência baseado em sistemas inteligentes e na aplicação das transformadas de Clarke e Wavelet. A abordagem inteligente utilizada permite analisar a condição operativa dos transformadores de potência e detectar a ocorrência de defeito interno, distinguindo-a de outras situações de operação, como, a energização, a energização solidária, a saturação dos transformadores de corrente e a sobreexcitação. As tomadas de decisão das técnicas desenvolvidas são realizadas pela lógica fuzzy após o pré-processamento dos sinais de entrada por meio de diversos métodos, os quais variam de acordo com o algoritmo que esta sendo executado. Os algoritmos propostos foram testados por meio de simulações realizadas através do software Alternative Transients Program (ATP). É importante salientar que nas simulações do ATP foram modelados diversos equipamentos que constituem o sistema elétrico de potência, incluindo um gerador síncrono com regulação de velocidade, linhas de transmissão com variação em frequência, transformadores de potência com suas respectivas curvas de saturação, transformadores de potencial e de corrente. Estas modelagens tiveram por objetivo gerar dados das distintas situações de operação para a verificação e análise da metodologia proposta. Os resultados da pesquisa mostram a aplicabilidade dos algoritmos propostos na proteção e no monitoramento dos transformadores de potência, mesmo nas condições mais adversas, como na ocorrência da saturação dos transformadores de corrente, uma vez que os sinais de entrada distorcidos pela saturação são corrigidos por uma rede neural artificial. Os resultados apresentados comparam as respostas obtidas pelas técnicas propostas em relação às saídas de um relé comercial, habilitado à proteção diferencial percentual. / This work presents a set of methods for protecting and monitoring power transformers based on intelligent systems and the application of Clarke and Wavelet transforms. The intelligent approach allowed us to analyze the operating condition of power transformers and it discriminates between an internal fault and different operating conditions, as energization, sympathetic inrush, saturation of current transformers and overexcitation. Decision making is performed by fuzzy logic after the preprocessing of the input signals through various methods, varying according to which algorithm is running. It is important to point out that in the simulations using ATP many different power system equipment had been modeled, including a synchronous generator with speed regulation, transmission lines with variation in frequency, power transformers with their saturation curves, potential transformers and current transformers. The objective of these tests was to generate data for distinct situations for the verification and the analysis of the proposed methodologies. The results of the research show the applicability of the algorithms considered in protection and monitoring of power transformers, even in adverse conditions, such as saturation of current transformers, since the input signals are distorted by CT saturation corrected by artificial neural network. The results are compared to the ones presented by a commercial percentage differential relay.
119

Transformada Wavelet e técnicas de inteligência computacional aplicadas à identificação, compressão e armazenamento de sinais no contexto de qualidade da energia elétrica / Wavelet transform and soft computing techniques applied to identification, compression and storage of signals in the power quality context

Andrade, Luciano Carli Moreira de 06 July 2017 (has links)
A presença de distúrbios na energia elétrica fornecida aos consumidores pode causar a diminuição no tempo de vida útil dos equipamentos, mal funcionamento ou até mesmo sua perda. Desse modo, ferramentas capazes de realizar a detecção, localização, classificação, compressão e o armazenamento de sinais de forma automática e organizada são essenciais para garantir um processo de monitoramento adequado ao sistema elétrico de potência como um todo. Dentre as ferramentas comumente aplicadas às tarefas supramencionadas, pode-se destacar a Transformada Wavelet (TW) e as Redes Neurais Artificiais (RNAs). Contudo, ainda não foi estabelecida uma metodologia para obtenção e validação da TW e seu nível de decomposição, bem como da arquitetura e da topologia de RNAs mais apropriadas às tarefas supracitadas. O principal fato que levou a esta constatação deve-se à análise da literatura correlata, onde é possível notar o uso de distintas TW e RNAs. Neste contexto, a primeira contribuição desta pesquisa foi o projeto e desenvolvimento de um método eficiente de segmentação de sinais com distúrbios associados à Qualidade da Energia Elétrica (QEE). O método desenvolvido se beneficia das propriedades da TW de identificação temporal de descontinuidades em sinais. A segunda contribuição é o desenvolvimento de um algoritmo automático que, por meio do método de segmentação desenvolvido e de classificação por RNAs, indique as melhores ferramentas (Wavelets e RNAs) para as tarefas de segmentação, extração de características e classificação de distúrbios de QEE. Esse algoritmo foi desenvolvido com base nos recursos dos Algoritmos Evolutivos (AEs) e adotou RNAs do tipo Perceptron Multicamadas, pois, esta arquitetura pode ser considerada consagrada no que se refere à classificação de padrões. Por fim, a terceira contribuição é relativa ao desenvolvimento de um procedimentos baseados em AEs, a fim de se aprimorar métodos de compressão de dados que preservem as informações relevantes nos sinais de QEE. Assim, é importante mencionar que os resultados dessa pesquisa poderão determinar mecanismos automáticos a serem utilizados no processo de registro, tratamento e armazenamento de informações que serão importantes para se manter um banco de dados (histórico) atualizado nas concessionárias de energia, a partir do qual, índices e um melhor mapeamento e entendimento de todos os distúrbios relacionados à QEE poderão ser melhor entendidos e solucionados. / The presence of disturbances in the electrical power supplied to consumers can decrease the lifetime of the equipment, cause malfunction or even their breakdown. Thus, tools able to perform detection, localization, classification, compression and storage of signals automatically and organized manner are essential to ensure adequate monitoring process to electric power systems as a whole. Among the tools commonly applied to the tasks mentioned above, one can highlight the Wavelet Transform (WT) and Artificial Neural Networks (ANN). However, the WT has not been established yet and nor its level of decomposition, as well as the most appropriate ANN architecture and topology to the tasks already mentioned. The main fact that has led to this finding is due to the review of related literature, where it is possible to note the use of distinct WT and ANN. Therefore, the first contribution of this research was the design and development of an efficient method of segmentation of signals associate to Power Quality (PQ) disturbances. The developed method take advantage of WT properties of temporal identification of signal discontinuities. The second contribution is the development of an automatic algorithm that, through the segmentation method developed and classification by ANN, indicates the best tools (Wavelets and ANN) for the tasks of segmentation, extraction of characteristics and classification of QEE disturbances. This algorithm was developed based on the resources of the Evolutionary Algorithms and it adopts Multi-layered Perceptron type ANN, once this architecture can be considered consecrated with regard to the pattenrs classification. Finally, the third contribution is related to the development of EA based procedures in order to improve data compression methods that preserve the relevant information in the PQ signals. Thus, it is important to mention that the results of this research may determine automatic mechanisms to be used in the process of recording, processing and storing information that will be important in order to maintain an up-to-date (historical) database in the utilities, from which , indexes and a better mapping and understanding of all PQ related disturbances can be better understood and solved.
120

Investigação experimental de estratégias de identificação e controle LPV aplicadas ao amortecimento de oscilações eletromecânicas em sistemas elétricos de potência

NOGUEIRA, Fabrício Gonzalez 29 June 2012 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2013-02-14T15:22:56Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_InvestigacaoExperimentalEstrategias.pdf: 9412323 bytes, checksum: 50583a37f03cba4a2d9ea1e386b33b19 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2013-02-14T16:50:29Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_InvestigacaoExperimentalEstrategias.pdf: 9412323 bytes, checksum: 50583a37f03cba4a2d9ea1e386b33b19 (MD5) / Made available in DSpace on 2013-02-14T16:50:29Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_InvestigacaoExperimentalEstrategias.pdf: 9412323 bytes, checksum: 50583a37f03cba4a2d9ea1e386b33b19 (MD5) Previous issue date: 2012-06-29 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Nesta tese e realizada a investigação experimental de uma estratégia de controle LPV (do inglês, linear parameter varying) aplicada ao amortecimento de oscilações eletromecânicas em sistemas elétricos de potencia. O estudo foi realizado em um modelo de sistema de potencia em escala reduzida de 10kVA, cuja configuração e do tipo maquina interligada a uma barra infinita, alem de testes em campo em uma unidade geradora de 350 MVA da Usina Hidrelétrica de Tucuruvi. Primeiramente, foi desenvolvido e testado computacionalmente um conjunto de rotinas para analise e síntese de controlador amortecedor do tipo LPV, bem como para identificação de modelos LPV da planta. Os coeficientes do controlador amortecedor LPV, no caso um Estabilizador de Sistemas de Potencia (ESP), dependem do valor de uma variável de operação selecionada que, neste estudo, foram as potencias ativa (P) e reativa (Q) nos terminais da unidade geradora. Para fins de projeto, a dinâmica da planta foi representada através de um modelo ARX LPV, o qual foi estimado a partir de dados coletados experimentalmente na planta, para uma ampla faixa de condições operacionais. A partir do modelo LPV da planta, os valores dos parâmetros do ESP LPV foram determinados via um problema de otimização convexa, na forma de uma LMI parametrizada (PLMI). A solução da PLMI e obtida a partir de uma relaxação via decomposição em soma de quadrados. O ESP LPV foi projetado de modo a garantir a estabilidade e o desempenho do sistema para uma ampla faixa de condições operacionais da planta, o que geralmente não e possível de obter com controladores convencionais a parâmetros fixos. A lei de controle amortecedor do ESP LPV foi implementada em um sistema embarcado baseado em um controlador digital de sinais. Os resultados experimentais mostraram um excelente desempenho do ESP LPV no amortecimento de oscilações eletromecânicas, tanto no sistema de potencia em escala reduzida, quanto em uma unidade geradora da UHE de Tucurui. / In this thesis is performed an experimental investigation of the performance of a LPV (linear parameter varying) control strategy applied to damp electromechanical oscillations in electric power systems. The study was performed in a 10kVA electric power system, which is configured as a single machine connected to an infinite bus. Furthermore, were also performed field tests on a generating unit of Tucurui Hydroelectric Power Plant. Firstly, a set of routines for the analysis and synthesis of LPV damping controllers were developed and tested computationally, along with routines for the identification of LPV models of the plant. The coefficients of the LPV damping controller, in this case a power system stabilizer (PSS), depends on the value of a variable representative of the system operating condition (scheduling parameter), which in this study, were the terminal active power (P) and reactive power (Q) of the generating unit. For control ends, the dynamics of the plant was represented by an ARX LPV model, which was estimated from experimental data collected in the plant for a wide range of operating conditions. From the LPV model of the plant, the values of the parameters of the LPV controller were determined via an optimization problem, in the form of a parameterized LMI (PLMI). The solution of PLMI is obtained from a relaxation via sum-of-squares decomposition. The LPV PSS was designed to ensure stability and performance for a wide range of operating conditions of the plant, which is generally not possible to obtain with conventional fixed parameter controllers. The LPV PSS control law was implemented in an embedded system based on a digital signal controller. The experimental results showed an excellent performance of the LPV PSS on the damping of the electromechanical oscillations both in the 10kVA electric microgenerator system, and in the Tucurui generating unit.

Page generated in 0.386 seconds