• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1889
  • 646
  • 119
  • 14
  • 13
  • 11
  • 9
  • 9
  • 9
  • 8
  • 6
  • 5
  • 5
  • 5
  • 5
  • Tagged with
  • 2741
  • 950
  • 896
  • 392
  • 349
  • 349
  • 324
  • 304
  • 302
  • 266
  • 257
  • 231
  • 223
  • 220
  • 213
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Utilização de ondas sônicas e ultra-sônicas para obtenção de DNA em amostras de músculo humano

GIUSTINA, Ana Carolina Bernardi Della 31 January 2009 (has links)
Made available in DSpace on 2014-06-12T15:51:05Z (GMT). No. of bitstreams: 2 arquivo1556_1.pdf: 2318701 bytes, checksum: 17bdd9ba90f170f7729cd0b7d83b3c1c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2009 / A obtenção de DNA com finalidades forenses pode ser dividida em duas etapas, a digestão ou lise da amostra, liberando as moléculas de DNA na solução, e a purificação, que torna o DNA acessível às outras etapas do processo. Os métodos de lise celular em uso corrente na rotina laboratorial forense incluem variações de temperatura e uso de substâncias químicas como proteinase K, detergentes e agentes redutores em um processo bastante demorado e de alto custo. Neste trabalho, dois novos métodos de obtenção de DNA de músculo humano utilizando sondas sônicas (8 KHz) e ultra-sônicas (24 KHz) foram desenvolvidos. Empregando ondas sônicas é possível realizar a lise completa de amostras de músculo em tampão Tris-HCl 10 mM, pH 8.0 contendo 2% de SDS em apenas dois minutos. Utilizando ondas ultra-sônicas é possível a obtenção de DNA em água Milli- Q em dois minutos e sem a necessidade de etapas posteriores de purificação. Ambos os métodos resultaram em quantidades suficientes de DNA para identificação humana em ciência forense, entretanto, as amostras sonicadas resultaram em quantidades de DNA significativamente maiores que as obtidas das amostras submetidas ao ultra-som
222

Otimização das condições de soldagem nos processos de ultra-som e resistencia para aluminio e cobre

Zampolli, Daniella Machado 30 October 2000 (has links)
Orientador : Roseana da Exaltação Trevisan / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-27T22:10:04Z (GMT). No. of bitstreams: 1 Zampolli_DaniellaMachado_M.pdf: 8042922 bytes, checksum: 53f345f393039164e10eb600d4054058 (MD5) Previous issue date: 2000 / Resumo: Neste trabalho, procurou-se encontrar as melhores junções soldadas, de alumínio e cobre, por ultra-som e por resistência a ponto, através de uma otimização destes processos, com o emprego de um planejamento fatorial completo e do método estatístico da superficie de respo_ Posteriormente, realizou-se uma comparação entre as propriedades especificadas para a peça, resistência ao cisalhamento, resistência ao arrancamento e resistência elétrica. Os materiais utilizados foram as ligas de alumínio AA1100-0e de cobre C1O200, a partir das quais soldou-se as junções alumínio/alumínio, cobre/cobre e alumínio/cobre, utilizadas em um mancal porta-escovas, fabricado pela empresa Robert Bosch do Brasil. Os resultados obtidos mostraram que, de um modo geral, o processo de ultra-som gerou as junções mais apropriadas para aplicação na peça, além de outras vantagens mais específicas complementares, como maior facilidade, rapidez de soldagem e condições de trabalho menos severas ao operador. As junções alumínio/alumínio foram soldadas por ambos os processos, tendo-se obtido resultados bastante próximos. Quanto às junções cobre/cobre e alumínio/cobre, a soldagem mostrou-se válida através do processo de ultra-so_ enquanto que o processo por resistência não foi apropriado para os tipos de materiais utilizados. Para todas as soldagens, as ferramentas estatísticas utilizadas trouxeram resultados confiáveis, já que apresentaram embasamento teórico / Abstract: In this work, the objective was to find the best junctions welded by the ultrasound and the spot resistance welding processes, through an optimization of their main parameters, employing a complete factorial planning and the statistic method of the surface response. Lately, it was performed a comparison among the specified properties for the unions, shear resistance, peel resistance and electric resistance. The utilized materials were the alluminum AAII00-0 and the copper CI0200 alloys, with which the unions alluminumlalluminum, copper/copper and alluminumlcopper were welded, and which are employed in an automotive electric part, produced by the Robert Bosch do Brasil company. The obtained results showed that, in a general way, the ultrasound process produced the most applicable junctions for the part, and also other more specific complementary advantages, like an easier, cleaner and faster welding and some less severe work conditions for the worker. The junctions alluminumlalluminum were welded by both processes, being the results very close one to the other. For the junctions copper/copper and alluminumlcopper, the welding was successful through the ultrasound process, while through the resistance process, the results with the employed materials were not satisfactory. The studied statistical tools brought trustful results for all the experiments, since they were based in theoretical concepts / Mestrado / Materiais e Processos de Fabricação / Mestre em Engenharia Mecânica
223

Tratamento multimidia da variação individual do canto de Troglodytes aedon (Troglodytidae) na cidade de Campinas, Estado de São Paulo / Multimedia treatment of the individual variation of the song of Troglodytes aedon (Troglodytidae) in the city Campinas, State de São Paulo

Corbo, Milena Cristina 12 August 2018 (has links)
Acompanha 1 CD-ROM / Orientador: Jacques Marie Edme Vielliard / Dissertação (mestrado) - Universdidade Estadual de Campinas, Instituto de Artes / Made available in DSpace on 2018-08-12T16:48:24Z (GMT). No. of bitstreams: 1 Corbo_MilenaCristina_M.pdf: 9930237 bytes, checksum: 416a118da2c24ccabc6090073e6958c3 (MD5) Previous issue date: 2007 / Resumo: O repertório de Troglodytes aedon é bastante complexo, apresentando variações intra e inter-individuais. Neste trabalho os indivíduos foram gravados usando o gravador de rolo NAGRA-E com auxílio de um microfone cardióide dinâmico montado em uma parábola acústica. Os 29 indivíduos analisados apresentaram um total de 113 tipos de notas e 177 tipos de cantos. Dessas notas, 20 foram únicas, mas todos os individuos também emitiram notas em comum. Cada frase foi composta de 6 a 34 notas com duração entre 0,9 e 4 segundos. Cada tipo de frase foi emitido de 10 a 60 vezes seguidas antes do cantor mudar para outro tipo. As frases foram divididas em três partes: inicial, central e final, cada uma apresentando notas específicas. Foram analisados também cantos de outros estados brasileiros e de alguns países da América do Sul. Os cantos de todos os indivíduos apresentaram notas em comum. Nenhum tipo de canto foi compartilhado entre os indivíduos analisados, pois apesar de os indivíduos usarem em parte as mesmas notas, a forma de emissão destas assumiu diversas posições seqüênciais dentro das respectivas partes do canto. Tal estrutura de organização de canto pressupõe um modo peculiar de aprendizagem que presisa ser decifrado. / Abstract: The repertoire of Troglodytes aedon is large and its song, fairly complex, presents inter-individual variations. The singers have been recorded on open-reel NAGRA-E with a dynamic cardioid microphone mounted on an acoustic parabola. The 29 individuals that have been analyzed presented a total of 113 types of notes and 177 song-types. Of the notes, 20 were unique, but all individuals emitted also notes in common. Each phrase is normally composed of 6 to 34 notes with duration between 0.9 and 4 seconds. Each type of phrase was emitted 10 to 60 times before the singer switches to another song-type. The phrases were divided into three parts: initial, central and final, each one presenting specific notes. Were analyzed also songs from other Brazilian states and some countries in South America. They all presented notes in common. No song-type has been shared between the individuals analyzed, because even though the individuals used in part the same notes, they emitted them in diverse sequence positions within their respective parts of the song. This structure assumes an uncommon way to learn that should be interpreted. / Mestrado / Mestre em Multimeios
224

Efeito terapêutico do ultra-som na osteorradionecrose dos maxilares / Therapeutic ultrasound effect in osteoradionecrosis of the jaws

Rhoner Gonçalves 11 December 2009 (has links)
O trabalho buscou demonstrar o efeito benéfico do ultra-som no controle sintomático das osteorradionecroses (ORN) dos maxilares. Dez pacientes portadores de ORN dos maxilares foram avaliados e completaram o protocolo de tratamento proposto: um máximo de 40 aplicações de 20 minutos de ultra-som (US) de baixa intensidade sobre a área facial correspondente à região afetada pela ORN. O aparelho utilizado dispõe de transdutor composto por um disco cerâmico de PZT (Titanato de Zirconato de Chumbo) que emite ondas longitudinais, com freqüência de 1,5 Mhz e potência de 30 mW. Oito homens e duas mulheres compuseram a casuística, com idade média de 52,7 anos. Nove pacientes apresentavam ORN em mandíbula e um em maxila. Todos os pacientes mostraram resposta positiva ao tratamento com US, sendo que três foram tratados exclusivamente com US e sete submeteram-se a intervenção cirúrgica após as 40 aplicações de US. Extensão da casuística e pesquisas adicionais são indispensáveis ao melhor esclarecimento dos mecanismos de ação do US sobre o metabolismo ósseo, de sua interferência sobre o osso irradiado e para o estabelecimento de protocolos de tratamento clínico efetivos e cientificamente embasados. Concluímos que a terapia de US de baixa intensidade é eficiente no tratamento de ORNs dos maxilares, apresentando ausência de efeitos colaterais adversos e boa aceitação por parte dos pacientes. / The purpose of this research was to evaluate the effect of ultrasound (US) therapy upon symptomatic control of osteoradionecrosis (ORN) of the jaws. Ten ORN patients that completed the designed treatment protocol had their data analyzed. The treatment protocol consisted of a maximum of 40 sessions of 20-minute low intensity US application over the face in the area correspondent to the ORN lesion. The US device utilized was composed of a ceramic disc transducer (lead titanate zirconate) with 1.5 mHz frequency and 30 mW of power. Eight men and two women comprised the population studied, mean age 52.7 years. Nine patients presented the mandible and one patient the maxilla affected by ORN. All patients showed good results to US treatment. Three were treated exclusively by US and seven were submitted to a supplementary surgery intervention after the programmed 40 US applications. The extension of the casuistic and additional research are mandatory to enlighten the interactions between US waves and bone metabolism, the interferences of US upon irradiated bone and to the development of effective treatment protocols scientifically supported. It was concluded that US therapy is efficient to treat jaws osteoradionecrosis, generating no adverse effects and being well accepted by the patients.
225

Uso de matriz óssea desmineralizada associada a estimulação ultra-sônica pulsada de baixa intensidade na correção de falha óssea: estudo experimental em coelhos / not available

Ana Paula Marzagão Casadei Carro 25 August 1998 (has links)
No presente trabalho, procurou-se investigar o efeito do ultra som pulsado de baixa intensidade corno um agente acelerador do princípio indutor da matriz óssea desmineralizada, utilizada no preenchimento de falhas ósseas, criadas experimentalmente na diáfise do rádio de coelhos. Foram criadas falhas na diáfise do rádio de aproximadamente 1 cm de comprimento, tentando-se preservar ao máximo o periósteo. As falhas foram preenchidas com pó de osso desmineralizado. Os animais foram estimulados com o ultra som, durante 15 dias consecutivos após a cirurgia e foram observados pôr até 30 dias, tendo sido sacrificados aos 15, 30 e 45 dias após a cirurgia. Os resultados foram avaliados radiológica e histologicamente nos 3 períodos, possibilitando um estudo da evolução do processo osteogênico. As falhas ósseas preenchidas com matriz óssea desmineralizada e que receberam o estímulo com o ultra som de baixa intensidade apresentaram uma sensível aceleração no processo de formação de osso, demonstráveis histológica e radiologicamente. / In the present work, it has been investigated the effect of the low intensity pulsed ultrasound on the use of demineralized bone matrix used as bone gap filling material in experimental diaphysial osteotomies of rabbit radius bone. Preserved periosteum 1 cm bone gaps have been surgically created in the radius bone diaphysis and filled with demineralized bone powder. The experimental animals received the ultrasound stimulus for 15 days following the surgery and were observed for until 30 days. The sacrifices were performed 15, 30 and 45 days after surgery. In order to study the healing process evaluation were performed at the end of the 3 periods. The bone gaps whose received demineralized bone matrix and low intensity and low intensity ultrasound simulation presented a remarkable aceleration in the bone formation process as shown by histological and radiological evaluation.
226

Aplicação do ultra-som terapêutico em lesão muscular experimental aguda / not available

Denise Ferreira de Menezes 17 December 1997 (has links)
Este estudo analisou o efeito da aplicação do ultra-som terapêutico em lesão muscular aguda. Foi realizada uma lesão por esmagamento no músculo reto anterior do quadríceps direito e esquerdo em 26 coelhos (52 músculos) da raça Nova Zelândia, com peso médio de 2,2 kg. Após 3 dias da lesão, os animais foram tratados em um lado com ultra-som terapêutico com tipo de onda pulsada, freqüência de 1 MHz e intensidade de 0,5 W/cm2 por 5 minutos, durante 10 dias consecutivos. O músculo contralateral serviu como controle e sofreu apenas esmagamento. Após 3 dias do término da aplicação, os animais foram sacrificados e os músculos submetidos a ensaios de tração na máquina universal de ensaio, com célula de carga de 200 kgf e velocidade de 4,5 mm/minuto. Foram analisados os resultados dos ensaios de 36 músculos (18 animais), mostrando que os músculos tratados pelo ultra-som apresentaram diferença significativa na deformação máxima, carga e deformação no limite de proporcionalidade, e na energia na fase de deformação elástica. Estes resultados sugerem que a aplicação do ultra-som terapêutico pode ser benéfica para melhorar a qualidade da reparação da lesão muscular aguda. / In this investigation the effect of the therapeutic ultrasound on the healing of acute muscular lesion was evaluated. The injury was produced with a crush on the rectus femoris in 26 New Zealand white rabbits (52 muscles). Three days later pulsed ultrasound was applied to the injuried area and the opposite side muscle was kept a control. The ultrasound pulsed waves had 1 MHz of frequency, 0,5 W/cm2 of intensity and they were applied during 5 minutes for 10 days. Three days after completion of the treatment the animal was killed and the muscle submited to mechanical testing in traction. The muscles treated by ultrasound showed higher loads and deformation at the yield limit and absorbed more energy in the elastic phase. The results suggest that acute muscular lesions may benefit from the application of pulsed ultrasound in the acute phase of the reparative process.
227

Desenvolvimento de um sistema de medida de tempo decorrido da onda ultra-sônica e análise do estado de tensões em materiais metálicos pela técnica da birrefiingência acústica

Bittencourt, Marcelo de Siqueira Queiroz, Instituto de Engenharia Nuclear 03 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-09-06T14:26:13Z No. of bitstreams: 1 MARCELO DA SIQUEIRA QUEIROZ BITTENCOURT_D_2000.pdf: 4551219 bytes, checksum: 374ed38139b75087e6417c59c553d869 (MD5) / Made available in DSpace on 2017-09-06T14:26:13Z (GMT). No. of bitstreams: 1 MARCELO DA SIQUEIRA QUEIROZ BITTENCOURT_D_2000.pdf: 4551219 bytes, checksum: 374ed38139b75087e6417c59c553d869 (MD5) Previous issue date: 2000-03 / A medida de tensão por ultra-som se baseia no efeito acustoelástico, que é o fenômeno da variação da velocidade da onda ultra-sônica em função da tensão no material. Para isso, é necessário realizar medidas do tempo de percurso da onda ultra-sônica com elevada precisão e com resolução de nanossegundo. Este trabalho apresenta a montagem de um sistema ultra-sônico e o desenvolvimento e a aplicação de um novo método para a medida de tempo de percurso da onda ultra-sônica para medida de tensão em materiais. Este método utiliza o processamento do sinal pela correlação cruzada e do aumento da taxa de amostragem utilizando a técnica multitaxas. Foi verificada a utilização do método para avaliação de tensões, tanto aplicadas como residuais, em chapas de alumínio e aço, utilizando a técnica ultra-sônica da birrefringência. É apresentado, também, utilizando o sistema ultra-sônico montado, um processo para a determinação da direção de laminação de chapas. Foi mostrado que o método alcança a precisão e resolução necessárias a sua aplicação para avaliação das tensões tanto aplicadas como residuais, dos materiais examinados. O trabalho, além de mostrar alguns caminhos que geram imprecisão de medida ou que levam muito tempo para se chegar a uma solução, sem que com isso se ganhe em precisão, mostra também opções diferentes de processamento de sinal, fenômenos que podem ser utilizados para separar a influência da direção de laminação na tensão, e equipamentos que devem ou não ser utilizados, pois podem melhorar a resolução da medida. Mostra, também, que a técnica da birrefringência é apropriada para a verificação de tensão residual em chapas soldadas e pode ser usada na avaliação do alívio de tensões residuais por tratamentos térmicos. / Stress measurements by ultrasonic sound waves is based on the acoustoelastic effect that is the phenomenon of the variation of the velocity of the ultrasonic sound wave in a material as a function of the applied stress field. For that purpose it is necessary to measure the ultrasonic time of flight with high precision and with nanosecond resolution. This work describes the assembly of an ultrasonic system, and develops a new method to measure the ultrasonic time of flight in materials under stress. The method proposed uses the cross correlation signal processing of the ultrasonic wave and increases the sampling rate of the signal using the multi-rate technique. The birefringence ultrasonic technique, in conjunction with the measurement method developed, was successfully applied for the evaluation of applied and residual tensions in aluminum and steel plates. Using the assembled ultra-sonic system, it is also proposed a process for the determination of the rolling direction of plates by ultrasonic sound waves. For the materials examined, it was shown that the ultrasonic method reaches the precision and the necessary resolution for the evaluation of residual stresses and tension stresses due to externally applied forces. The work also discusses some of the factors that cause measurement imprecision, or that increase in the solution time without any gain in precision. It also shows different options for signal processing, discusses some of the phenomena that can be explored to separate the influence of the rolling direction in the evaluation of the material tension state, and introduces additional equipment that may be used to improve the resolution of the measure. The work concludes by showing that the acoustic birefringence technique is suitable for the verification of residual tension in welded plates and that it can also be used in the assessment of heat treatments for the stress relief in materials.
228

Redução de dimensionalidade usando Isomap aplicada ao áudio espacial / Dimensionality reduction using Isomap applied to spatial audio

Grijalva Arévalo, Felipe Leonel, 1984- 26 August 2018 (has links)
Orientadores: Luiz César Martini, Siome Klein Goldenstein / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-26T03:56:26Z (GMT). No. of bitstreams: 1 GrijalvaArevalo_FelipeLeonel_M.pdf: 1718764 bytes, checksum: cfa07a9c26c4179bec4656e94680c0b1 (MD5) Previous issue date: 2014 / Resumo: Conforme as aplicações de realidade aumentada tornam-se mais relevantes, há um crescente esforço na pesquisa do áudio espacial. O termo áudio espacial refere-se ao conjunto de técnicas onde a anatomia de uma pessoa (i.e. o pavilhão da orelha, a cabeça e o torso) é modelada por meio de filtros digitais. Ao filtrar uma fonte de áudio através desses filtros, o ouvinte é capaz de perceber um som como se ele fosse reproduzido em um local específico no espaço. No domínio da frequência, esses filtros são conhecidos como Funções de Transferência Relativas à Cabeça (Head-Related Transfer Functions, HRTF). Nesta dissertação, estabelecem-se os princípios básicos do áudio espacial, fornecendo uma analise das características espectrais das HRTFs. Além disso, como essas características espectrais diferem de uma pessoa para outra, propõe-se um novo método baseado em antropometria para personalizar HRTFs no plano horizontal. O método usa o Isomap, redes neurais artificias e um procedimento de reconstrução baseado na vizinhança. Assim, modificou-se a construção do grafo do Isomap para ressaltar a individualidade das HRTFs e efetuar uma redução de dimensionalidade não linear das HRTFs. Em seguida, utilizou-se uma rede neural artificial para modelar as relações não lineares entre as características antropométricas e as HRTFs de baixa dimensionalidade. E finalmente, usou-se uma abordagem de reconstrução com base na vizinhança para reconstruir a HRTF a partir do seu equivalente de baixa dimensionalidade. As simulações mostram que a abordagem proposta tem um desempenho melhor do que o PCA (Principal Component Analysis, Analise de Componentes Principais) e confirmam que o Isomap é capaz de descobrir as relações não lineares subjacentes da percepção auditiva / Abstract: As auditory augmented reality applications become more important, there is increasing effort in spatial audio research. The term spatial audio refers to techniques where a person's anatomy (i.e. the pinnae, head and torso) is modeled as digital filters. By filtering a sound source with these filters, a listener is capable of perceiving a sound as though it were reproduced at a specific spatial location. In the frequency domain, these filters are known as Head-Related Transfer Functions (HRTFs). This thesis states the basic principles of spatial audio and provides an analysis of the spectral characteristics of HRTFs. Moreover, since these spectral features differ among individuals, we introduce a new anthropometric-based method for customizing of HRTFs in the horizontal plane. The method uses Isomap, artificial neural networks (ANN), and a neighborhood-based reconstruction procedure. We first modify Isomap's graph construction step to emphasize the individuality of HRTFs and perform a customized nonlinear dimensionality reduction of the HTRFs. We then use an ANN to model the nonlinear relationship between anthropometric features and our low-dimensional HRTFs. Finally, we use a neighborhood-based reconstruction approach to reconstruct the HRTF from the estimated low-dimensional version. Simulations show that our approach performs better than PCA (Principal Component Analysis) and confirm that Isomap is capable of discovering the underlying nonlinear relationships of sound perception / Mestrado / Engenharia de Computação / Mestre em Engenharia Elétrica
229

Analise teorica e experimental de estrategias de controle ativo de ruido

Donadon, Lazaro Valentim 30 August 2002 (has links)
Orientador : Jose Roberto de França Arruda / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-03T00:41:07Z (GMT). No. of bitstreams: 1 Donadon_LazaroValentim_D.pdf: 19736719 bytes, checksum: 756fe6ddaca218731867c24a7c8fea98 (MD5) Previous issue date: 2002 / Resumo: Este trabalho descreve a aplicação de métodos de controle ativo de ruído utilizando uma abordagem de filtragem adaptativa na configuração avanço, onde o objetivo é a observação do comportamento energético do sistema controlado. Os métodos de controle ativo testados foram o Filtered-X LMS no domínio do tempo e da freqüência e o ASIC (método de controle de intensidade sonora ativa) desenvolvido e implementado no domínio da freqüência. Este trabalho esta dividido em duas partes principais. Na primeira parte, os métodos de controle ativo foram testados em um ambiente acústico unidimensional constituído por um duto na forma de "T" com duas fontes acústicas. O modelo teórico do guia de ondas unidimensional foi desenvolvido utilizando o método dos elementos espectrais para o caso acústico. Neste experimento foram testadas as técnicas de medidas de intensidade sonora, potência radiada e sensores de velocidade de partícula. Os resultados teóricos e experimentais mostraram que o método dos elementos espectrais pode ser utilizado com sucesso para prever os fenômenos acústicos, e que não ocorrem diferenças significativas entre os métodos de controle ativo mesmo quando foram alteradas as funções de custo (troca dos sensores de pressão por sensores de velocidade de partícula). Na segunda parte, o algo ritmo Filtered-X LMS no domínio do tempo foi implementado em um cilindro com o intuito de atenuar o ruído interno quando este é gerado pela casca cilíndrica ou por uma fonte sonora externa à cavidade. Os esquemas de controle ativo testados foram o controle de vibração (A VC) e o controle ativo de ruído via atuação estrutural (ASAC). Demonstrou-se experimentalmente que, se o ruído interno é gerado pela vibração da casca cilíndrica, o melhor desempenho é atingido pelo controle de vibração, enquanto que, se o ruído é gerado por uma fonte externa, o controle ativo de ruído via atuação estrutural é a melhor alternativa / Abstract: This work describes applications of the active noise control techniques using adaptive feed forward filtering theory, where the objective is to analyze energetic behavior of the controlled system. The active noise control methods employed are the normalized filtered-X LMS in the time and frequency domain and the Active Sound Intensity Controller (ASIC), which is developed and implemented in the frequency domain. This thesis is divided m two main parts. In the first part, the active noise control methods are applied in an one-dimensional waveguide constituted by a T-shaped duct with two acoustic sources. The one-dimensional waveguide was modeled by the Spectral Element Method (SEM). In this experiment, the measurements include the sound intensity, the radiated acoustic power, and the partic1e velocity. The theoretical and experimental results show that the spectral element method can be used successfully to predict the acoustic phenomena in one-dimensional waveguides. Besides, there is no significant difference when different active noise control strategies are implemented, even when the cost functions were changed (the change in the error sensor type means a change in the cost function). In the second part, the normalized filtered-X LMS in the time domain is applied to attenuate the interior noise m a cylindrical cavity. The adaptive control schemes implemented were the Active Control of Vibration (A VC) and the Active Structural Acoustic Control (ASAC). Result obtained when the primary noise is generated by mechanically exciting the cylindrical shell and by using an external acoustical source are compared. It is shown that if the interior noise is generated by shaking the cylindrical shell, it is better to apply the A VC scheme, while if the interior noise is generated by an external acoustical source it is better to apply the ASAC scheme / Doutorado / Projetos Mecanicos / Doutor em Engenharia Mecânica
230

O uso da teoria do sistema nebuloso na avaliação da interpretação subjetiva de estimulos sonoros

Alvarenga, Benedito Sergio Tavares de 03 August 2018 (has links)
Orientador: Stelamaris Rolla Bertoli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T17:24:12Z (GMT). No. of bitstreams: 1 Alvarenga_BeneditoSergioTavaresde_M.pdf: 1200162 bytes, checksum: ac4e26b89e05718a132f263527a0ea0c (MD5) Previous issue date: 2003 / Mestrado

Page generated in 0.0321 seconds