• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelagem farmacocinética-farmacodinâmica do propofol em pacientes submetidos à cirurgia cardíaca com anestesia venosa contínua alvo-controlada / Propofol pharmacokinetic-pharmacodynamic modeling in patients submitted to cardiac surgery with continuous venous target controlled anesthesia

Valéria Adriana Pereira 11 January 2005 (has links)
O propofol é um sedativo eficiente, largamente empregado em anestesia e geralmente associado a grande números de analgésicos opióides em cirurgias de grande porte, como a cirurgia cardíaca de revascularização do miocárdio (RM) com ou sem circulação extracorpórea (CEG). Devido às suas características farmacocinéticas é administrado através de infusão alvo controlada (TCI) de forma a manter os níveis plasmáticos ótimos para obtenção de sedação e profundidade de anestesia adequadas durante a intervenção cirúrgica. O objetivo do presente estudo foi investigar a farmacocinética e farmacodinâmica do propofol administrado através de TCI em pacientes submetidos a RM com e sem CEC. Na administração da medicação hipnótica, fez-se necessária a validação do Diprifusor (AstraZeneca), incluindo a bomba de infusão e o software programado com o modelo farmacocinético de 3 compartimentos, que necessita apenas da inclusão de dados individuais do paciente, tais como peso corporal. A validação desse sistema compreendeu a estimativa do erro de previsão do Diprifusor pela utilização da razão das concentrações obtida, experimentalmente medida, e a prevista pelo modelo do software da bomba de infusão. No presente estudo comparativo, selecionaram-se 20 pacientes com base nos critérios de inclusão, que foram divididos em 2 grupos, Controle e CEC. Os pacientes foram informados em detalhes sobre os dados que cercam esse protocolo de pesquisa e assinaram o termo de consentimento livre esclarecido para participação no estudo. O protocolo for submetido e aprovado pelo CEP de todas as Instituições envolvidas (FCFUSP, InCor e CAPPesq). A taxa de infusão requerida, bem como a faixa de concentração obtida para manter o alvo de 2 µg/mL e o índice bispectral de 40 (BIS) durante a cirurgia cardíaca foram monitorados. Subsequentemente, ao final da cirurgia, a taxa de infusão e a faixa de concentração do propofol plasmático requeridos para atingir o alvo de 1 µg/mL também foram monitorados. Neste período, a sedação e a medida da profundidade da anestesia foram monitorados através do BIS e da Escala de Ramsay. O efeito medido através do BIS durante a infusão, no intra-operatório, atingiu o valor máximo de 40 da escala nos dois grupos. Da mesma forma, ao final da cirurgia, obteve-se nível 6 de sedação na escala de Ramsay em ambos os grupos, quando o alvo foi ajustado para 1 µg/mL. Adicionalmente pela interrupção da infusão, no pós-operatório imediato, BIS e Ramsay foram registrados simultaneamente até o final do período de estudo (18-20 horas) para todos os pacientes. Efetuou-se coleta de amostras sanguíneas durante as infusões alvo (2 µg/mL e 1 µg/mL) e após a interrupção da infusão para o estudo da farmacocinética . Requereu-se volume de sangue inferior a 90 mL para o monitoramento plasmático e a modelagem farmacocinética. Utilizou-se a cromatografia líquida de alta eficiência, com deteto r de fluorescência (CLAE-F). O método mostrou-se bastante simples, seletivo, sensível e robusto e utilizou coluna C18 e fase móvel binária em baixo fluxo. Os limites de confiança estabelecidos para o método analítico foram: 0,1-10 µg/mL (linearidade, r2 0,9977), 0,05 µg/mL (LD), 0,1 µg/mL(LQ), 93,9% (recuperação absoluta), 8,4 e 8,8% (precisão intra e inter dias), 91,8 e 93,3% (exatidão intra e inter dias). Adicionalmente, demonstrou-se boa estabilidade para o fármaco através de estudos de curta e longa duração, tempo de bandeja (tempo e condição de análise) e ciclos de congelamento e descongelamento, além de estudo de estabilidade das soluções padrão do propofol e do timol (padrão interno). No perioperatório, as concentrações plasmáticas evidenciaram alta flutuação, principalmente durante a intervenção para o grupo CONTROLE comparado ao grupo CEC, indicando maior erro de previsão na taxa de infusão estimada pelo software da bomba para manter o alvo no Controle. A modelagem farmacocinética foi efetuada pela aplicação do modelo aberto de 3 compartimentos que mostrou significativo aumento na eliminação do fármaco (ClT, ß, γ) no grupo CEC relativamente ao CONTROLE, uma vez que as concentrações plasmáticas obtidas no grupo CEC foram inferiores àquelas obtidas no outro grupo. A profundidade de anestesia alcançada foi de 6 na escala de Ramsay e 40 (BIS) durante a TCI , efeito máximo atingido durante essa cirurgia de alto porte. A função matemática sigmoidal foi escolhida com base na alta correlação obtida (r2 >0,9) pela modelagem PK¬PO. A curva de correlação do efeito BIS versus propofol plasmático indica que os grupos CEC e CONTROLE são diferentes, uma vez que apenas os pacientes do CONTROLE retornaram ao valor basal (BIS: 100) no período entre 6 e 8 horas do início da cirurgia e instalação da TCI de propofol. Por outro lado, registrou-se prolongamento do tempo de recuperação da hipnose (tempo de despertar) nos pacientes CEC, que se estendeu até 18 horas. Adicionalmente a modelagem indicou que a concentração efetiva (EC50) é da ordem de 4 vezes menor no grupo CEC comparado ao CONTROLE. Finalmente, apesar das menores concentrações plasmáticas para o propofol no grupo CEC, consequência da elevada depuração plasmática, o efeito máximo do hipnótico durante a intervenção foi semelhante nos dois grupos, sendo que a principal diferença entre eles reside na sedação residual registrada nos pacientes CEC. Esses resultados podem ser justificados em parte pelo aumento da fração livre de propofol no plasma e provavelmente em função de alteração na interação fármaco¬receptor, decorrência da CEC na cirurgia de revascularização do miocárdio. Em conclusão, a CEC afeta a farmacocinética e a farmacodinâmica do propofol no paciente cirúrgico. Por outro lado o dispositivo (Diprofusor, AstraZeneca) para a administração alvo controlada necessita de ajustes e adaptação para a TCI de propofol neste tipo de cirurgia, incluindo-se ainda no ajuste, a diferenciação para o paciente que possui a CEC associada. / Propofol is an effective sedative, largely applied in anesthesia and in general it is associated to opioids for analgesia in major surgeries, like the cardiac surgery to coronary artery bypass grafting (CABG) with or without cardiopulmonary bypass (CPB). It is administered by a target controlled infusion system (TCI) to maintain the optimal depth of sedation and anesthesia during the intervention, due to its pharmacokinetic characteristics. The objective of this study was to investigate the influence of CPB in pharmacokinetics and in pharmacodynamics of propofol, applying PK-PD modeling. For drug administration, Diprifusor (AstraZeneca), including pump plus software must enter individual data as body weight from the patient, once pharmacokinetic parameters were included previously. To validate this system of infusion, the prediction error by target controlled infusion must be estimated by comparison between obtained and predict concentration plasma ratio. In the present protocol, 20 patients (10 CONTROL and 10 CPB) were selected based on inclusion criteria for the comparative study. Patients were informed in details about the investigation and before the protocol starts, they signed the informed written consent to participate of the study. Protocol was approved by the local ethical committees of all institutions involved. Rate of infusion and the range of obtained plasma propofol concentrations required to reach 2 µg/mL and to maintain the bispectral index (BIS:40) during cardiac surgery were monitored. Subsequently, at the end of surgery, both rate of infusion and range of obtained plasma propofol concentrations required to reach 1 µg/mL were monitored either. Depth of sedation was assessed with BIS during all period reaching maximum effect in 40 at level of sedation in the operative period. At the end of surgery, the Ramsay score achieved sedation level 6, when the target plasma propofol was adjusted to 1 µg/mL; Additionally, at the end of infusion in the postoperative period, BIS and Ramsay were monitored simultaneously up to 18-20 hours for all patients. Blood samples were collected and propofol plasma levels were monitored during (TCI : 2 µg/mL) and after surgery (TCI: 1 µg/mL). Blood samples also were collected at the end of infusion for pharmacokinetics. Volumes of blood lower than 90 mL were necessary for drug monitoring and pharmacokinetic purposes. Plasma levels were determined by a quite simple, selective, sensitive and robustness analytical method HPLC, using fluorescence detector, C18 column, and binary system at low flow rate. Confidence limits were: 0.1-10 µg/mL (linearity, r2 0.9977), 0.05 µg/mL(LD), 0.1 flg/mL(LQ), 93.9% (absolute recovery), 8.4 and 8.8% (intra and inter day precision), 91.8 and 93.3% (accuracy intra and inter day). Additionally, good stability was shown for the drug and its internal standard (tymol). Plasma levels showed a large fluctuation for the CONTROL compared to CPB in the perioperative period, mainly during the surgical intervention, indicating a higher predicting error for CONTROL group. Pharmacokinetics applying three compartment open model showed significant increases on drug elimination (ClT, β, γ) for CPB compared to CONTROL, once plasma levels for CPB Group were lower than CONTROL in the period of study. Depth of sedation reached level 6 Ramsay score and 40 (BIS) during TCI, the maximum effect recorded during this major surgery. A sigmoidal mathematical function was choosed (r2>O.9) after PK-PD modeling. BIS effect versus propofol plasma concentration curve indicates that CPB patients are different from CONTROL, once only CONTROL patients recovered to baseline up to 6-8 hours of the starting of surgery, while a prolongation of recovery up to 18 hours, measured by awakening time, was observed in CPB patients; additionally, the effective concentration (EC50) was 4 times lower for CPB compared to CONTROL Group. Finally, in spite of lower plasma concentration in CPB, as a consequence of higher clearance, similar maximum effect were reached in both groups during the intervention and the main difference is based on a residual sedation in CPB patients after surgery. In fact, this data can be justified probably due to changes in free drug plasma levels and in drug-receptor interaction as a result of cardiopulmonary bypass in CABG surgery. In conclusion, cardiopulmonary bypass affects the pharmacokinetics and pharmacodynamics of propofol in CABG patients and the device for TCI (Diprifusor, AstraZeneca) must be adjusted for cardiac surgery with differences in CPB included.
2

Modelagem farmacocinética-farmacodinâmica do propofol em pacientes submetidos à cirurgia cardíaca com anestesia venosa contínua alvo-controlada / Propofol pharmacokinetic-pharmacodynamic modeling in patients submitted to cardiac surgery with continuous venous target controlled anesthesia

Pereira, Valéria Adriana 11 January 2005 (has links)
O propofol é um sedativo eficiente, largamente empregado em anestesia e geralmente associado a grande números de analgésicos opióides em cirurgias de grande porte, como a cirurgia cardíaca de revascularização do miocárdio (RM) com ou sem circulação extracorpórea (CEG). Devido às suas características farmacocinéticas é administrado através de infusão alvo controlada (TCI) de forma a manter os níveis plasmáticos ótimos para obtenção de sedação e profundidade de anestesia adequadas durante a intervenção cirúrgica. O objetivo do presente estudo foi investigar a farmacocinética e farmacodinâmica do propofol administrado através de TCI em pacientes submetidos a RM com e sem CEC. Na administração da medicação hipnótica, fez-se necessária a validação do Diprifusor (AstraZeneca), incluindo a bomba de infusão e o software programado com o modelo farmacocinético de 3 compartimentos, que necessita apenas da inclusão de dados individuais do paciente, tais como peso corporal. A validação desse sistema compreendeu a estimativa do erro de previsão do Diprifusor pela utilização da razão das concentrações obtida, experimentalmente medida, e a prevista pelo modelo do software da bomba de infusão. No presente estudo comparativo, selecionaram-se 20 pacientes com base nos critérios de inclusão, que foram divididos em 2 grupos, Controle e CEC. Os pacientes foram informados em detalhes sobre os dados que cercam esse protocolo de pesquisa e assinaram o termo de consentimento livre esclarecido para participação no estudo. O protocolo for submetido e aprovado pelo CEP de todas as Instituições envolvidas (FCFUSP, InCor e CAPPesq). A taxa de infusão requerida, bem como a faixa de concentração obtida para manter o alvo de 2 µg/mL e o índice bispectral de 40 (BIS) durante a cirurgia cardíaca foram monitorados. Subsequentemente, ao final da cirurgia, a taxa de infusão e a faixa de concentração do propofol plasmático requeridos para atingir o alvo de 1 µg/mL também foram monitorados. Neste período, a sedação e a medida da profundidade da anestesia foram monitorados através do BIS e da Escala de Ramsay. O efeito medido através do BIS durante a infusão, no intra-operatório, atingiu o valor máximo de 40 da escala nos dois grupos. Da mesma forma, ao final da cirurgia, obteve-se nível 6 de sedação na escala de Ramsay em ambos os grupos, quando o alvo foi ajustado para 1 µg/mL. Adicionalmente pela interrupção da infusão, no pós-operatório imediato, BIS e Ramsay foram registrados simultaneamente até o final do período de estudo (18-20 horas) para todos os pacientes. Efetuou-se coleta de amostras sanguíneas durante as infusões alvo (2 µg/mL e 1 µg/mL) e após a interrupção da infusão para o estudo da farmacocinética . Requereu-se volume de sangue inferior a 90 mL para o monitoramento plasmático e a modelagem farmacocinética. Utilizou-se a cromatografia líquida de alta eficiência, com deteto r de fluorescência (CLAE-F). O método mostrou-se bastante simples, seletivo, sensível e robusto e utilizou coluna C18 e fase móvel binária em baixo fluxo. Os limites de confiança estabelecidos para o método analítico foram: 0,1-10 µg/mL (linearidade, r2 0,9977), 0,05 µg/mL (LD), 0,1 µg/mL(LQ), 93,9% (recuperação absoluta), 8,4 e 8,8% (precisão intra e inter dias), 91,8 e 93,3% (exatidão intra e inter dias). Adicionalmente, demonstrou-se boa estabilidade para o fármaco através de estudos de curta e longa duração, tempo de bandeja (tempo e condição de análise) e ciclos de congelamento e descongelamento, além de estudo de estabilidade das soluções padrão do propofol e do timol (padrão interno). No perioperatório, as concentrações plasmáticas evidenciaram alta flutuação, principalmente durante a intervenção para o grupo CONTROLE comparado ao grupo CEC, indicando maior erro de previsão na taxa de infusão estimada pelo software da bomba para manter o alvo no Controle. A modelagem farmacocinética foi efetuada pela aplicação do modelo aberto de 3 compartimentos que mostrou significativo aumento na eliminação do fármaco (ClT, ß, γ) no grupo CEC relativamente ao CONTROLE, uma vez que as concentrações plasmáticas obtidas no grupo CEC foram inferiores àquelas obtidas no outro grupo. A profundidade de anestesia alcançada foi de 6 na escala de Ramsay e 40 (BIS) durante a TCI , efeito máximo atingido durante essa cirurgia de alto porte. A função matemática sigmoidal foi escolhida com base na alta correlação obtida (r2 >0,9) pela modelagem PK¬PO. A curva de correlação do efeito BIS versus propofol plasmático indica que os grupos CEC e CONTROLE são diferentes, uma vez que apenas os pacientes do CONTROLE retornaram ao valor basal (BIS: 100) no período entre 6 e 8 horas do início da cirurgia e instalação da TCI de propofol. Por outro lado, registrou-se prolongamento do tempo de recuperação da hipnose (tempo de despertar) nos pacientes CEC, que se estendeu até 18 horas. Adicionalmente a modelagem indicou que a concentração efetiva (EC50) é da ordem de 4 vezes menor no grupo CEC comparado ao CONTROLE. Finalmente, apesar das menores concentrações plasmáticas para o propofol no grupo CEC, consequência da elevada depuração plasmática, o efeito máximo do hipnótico durante a intervenção foi semelhante nos dois grupos, sendo que a principal diferença entre eles reside na sedação residual registrada nos pacientes CEC. Esses resultados podem ser justificados em parte pelo aumento da fração livre de propofol no plasma e provavelmente em função de alteração na interação fármaco¬receptor, decorrência da CEC na cirurgia de revascularização do miocárdio. Em conclusão, a CEC afeta a farmacocinética e a farmacodinâmica do propofol no paciente cirúrgico. Por outro lado o dispositivo (Diprofusor, AstraZeneca) para a administração alvo controlada necessita de ajustes e adaptação para a TCI de propofol neste tipo de cirurgia, incluindo-se ainda no ajuste, a diferenciação para o paciente que possui a CEC associada. / Propofol is an effective sedative, largely applied in anesthesia and in general it is associated to opioids for analgesia in major surgeries, like the cardiac surgery to coronary artery bypass grafting (CABG) with or without cardiopulmonary bypass (CPB). It is administered by a target controlled infusion system (TCI) to maintain the optimal depth of sedation and anesthesia during the intervention, due to its pharmacokinetic characteristics. The objective of this study was to investigate the influence of CPB in pharmacokinetics and in pharmacodynamics of propofol, applying PK-PD modeling. For drug administration, Diprifusor (AstraZeneca), including pump plus software must enter individual data as body weight from the patient, once pharmacokinetic parameters were included previously. To validate this system of infusion, the prediction error by target controlled infusion must be estimated by comparison between obtained and predict concentration plasma ratio. In the present protocol, 20 patients (10 CONTROL and 10 CPB) were selected based on inclusion criteria for the comparative study. Patients were informed in details about the investigation and before the protocol starts, they signed the informed written consent to participate of the study. Protocol was approved by the local ethical committees of all institutions involved. Rate of infusion and the range of obtained plasma propofol concentrations required to reach 2 µg/mL and to maintain the bispectral index (BIS:40) during cardiac surgery were monitored. Subsequently, at the end of surgery, both rate of infusion and range of obtained plasma propofol concentrations required to reach 1 µg/mL were monitored either. Depth of sedation was assessed with BIS during all period reaching maximum effect in 40 at level of sedation in the operative period. At the end of surgery, the Ramsay score achieved sedation level 6, when the target plasma propofol was adjusted to 1 µg/mL; Additionally, at the end of infusion in the postoperative period, BIS and Ramsay were monitored simultaneously up to 18-20 hours for all patients. Blood samples were collected and propofol plasma levels were monitored during (TCI : 2 µg/mL) and after surgery (TCI: 1 µg/mL). Blood samples also were collected at the end of infusion for pharmacokinetics. Volumes of blood lower than 90 mL were necessary for drug monitoring and pharmacokinetic purposes. Plasma levels were determined by a quite simple, selective, sensitive and robustness analytical method HPLC, using fluorescence detector, C18 column, and binary system at low flow rate. Confidence limits were: 0.1-10 µg/mL (linearity, r2 0.9977), 0.05 µg/mL(LD), 0.1 flg/mL(LQ), 93.9% (absolute recovery), 8.4 and 8.8% (intra and inter day precision), 91.8 and 93.3% (accuracy intra and inter day). Additionally, good stability was shown for the drug and its internal standard (tymol). Plasma levels showed a large fluctuation for the CONTROL compared to CPB in the perioperative period, mainly during the surgical intervention, indicating a higher predicting error for CONTROL group. Pharmacokinetics applying three compartment open model showed significant increases on drug elimination (ClT, β, γ) for CPB compared to CONTROL, once plasma levels for CPB Group were lower than CONTROL in the period of study. Depth of sedation reached level 6 Ramsay score and 40 (BIS) during TCI, the maximum effect recorded during this major surgery. A sigmoidal mathematical function was choosed (r2>O.9) after PK-PD modeling. BIS effect versus propofol plasma concentration curve indicates that CPB patients are different from CONTROL, once only CONTROL patients recovered to baseline up to 6-8 hours of the starting of surgery, while a prolongation of recovery up to 18 hours, measured by awakening time, was observed in CPB patients; additionally, the effective concentration (EC50) was 4 times lower for CPB compared to CONTROL Group. Finally, in spite of lower plasma concentration in CPB, as a consequence of higher clearance, similar maximum effect were reached in both groups during the intervention and the main difference is based on a residual sedation in CPB patients after surgery. In fact, this data can be justified probably due to changes in free drug plasma levels and in drug-receptor interaction as a result of cardiopulmonary bypass in CABG surgery. In conclusion, cardiopulmonary bypass affects the pharmacokinetics and pharmacodynamics of propofol in CABG patients and the device for TCI (Diprifusor, AstraZeneca) must be adjusted for cardiac surgery with differences in CPB included.

Page generated in 0.062 seconds