• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 111
  • 19
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 151
  • 151
  • 151
  • 51
  • 39
  • 25
  • 24
  • 24
  • 21
  • 18
  • 18
  • 17
  • 14
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
141

Quality indices of the final effluents of two sub-urban-based wastewater treatment plants in Amathole District Municipality in the Eastern Cape Province of South Africa

Gcilitshana, Onele January 2014 (has links)
Worldwide, water reuse is promoted as an alternative for water scarcity, however, wastewater effluents have been reported as possible contaminants to surface water. The failure of some wastewater treatment processes to completely remove organic matter and some pathogenic microorganisms allows them to initiate infections. This manifests more in communities where surface water is used directly for drinking. To assess water quality, bacteria alone cannot be used as it may be absent in virus-contaminated water. This study was carried out to assess the quality of two wastewater treatment plant effluents from the Eastern Cape Province of South Africa. Physicochemical parameters and microbiological parameters like faecal coliforms, adenovirus, rotavirus, hepatitis A virus, norovirus and enterovirus were evaluated over a projected period of one year. Physicochemical parameters were measured on site using multiparameters, faecal coliforms enumerated using culture-based methods and viruses are detected using both conventional and real-time PCR. Physicochemical parameters like electrical conductivity, turbidity, free chlorine and phosphates were incompliant with the standards set by the Department of Water affairs for effluents to be discharged. Faecal coliform counts were nil for one plant (WWTP-R) where they correlated inversely (P < 0.01) with the high free chlorine. For WWTP-K, faecal coliforms were detected in 27% of samples in the range of 9.9 × 101 to 6.4× 104 CFU/100ml. From the five viruses assessed, three viruses were detected with Rotavirus being the most abundant (0-2034176 genome copies/L) followed by Adenovirus (0–275 genome copies/L) then Hepatitis A virus (0–71 genome copies/L) in the WWTP-K while none of the viruses was detected in WWTP-R. Species B, species C and Adv41 serotypes were detected from the May 2013 and June 2013 samples where almost all parameters were incompliant in the plant. The detection of these viruses in supposedly treated effluents is suggestive of these being the sources of contamination to surface water and therefore renders surface waters unsafe for direct use and to aquatic life. Although real-time PCR is more sensitive and reliable in detection of viruses, use of cell-culture techniques in this study would have been more efficient in confirming the infectivity of the viruses detected, hence the recommendation of these techniques in future projects of this nature.
142

Prevalence of pathogenic Escherichia coli strains in the final effluents of four wastewater treatment plants in the Eastern Cape Province of South Africa

Seti, Nozuko Zukiswa January 2014 (has links)
Water is an essential need that stimulates health and well being. Increase in population size and urbanization negatively affect water resources due to high demands of effluent outputs. Wastewater is an important reservoir for Escherichia coli and can present significant acute toxicity if released into receiving water sources without being adequately treated. E. coli is used as indicator organism for the detection of faecal contamination. These strains have been considered to be one of the primary causes of diarrhoeal infections worldwide. The present study was conducted between September 2012 and June 2013 to assess the prevalence of pathogenic E. coli strains in the final effluents of four wastewater treatment plants in Chris Hani and Buffalo City Municipalities in the Eastern Cape Province of South Africa. Standard membrane filtration technique was used for bacteriological analysis and molecular based technique was used for identification of E. coli pathotypes. The results were recorded in colony forming units/100 ml. Faecal coliforms ranged between 0-9.6×10³ CFU/100 ml for the wwtp-Q and E. coli densities ranged between 0-8.4×10³ CFU/100ml. Faecal coliforms ranged between 4×10²-9.7×10³ CFU/100 ml for wwtp-M and E. coli densities ranged between 1.2×10¹-8.4×10³ CFU/100 ml. The wwtp-E showed to have bacterial counts of faecal coliforms ranging between 4.0×10³-8.2×10³ CFU/100 ml and E. coli densities ranging between 3.5×10¹-7.1×10³ CFU/100 ml. The WWTP-K in this study was only assessed for the presence of E. coli. Faecal coliforms were assessed by the other members of the group. This plant showed to have E. coli densities ranging between 0-7.5×10²CFU/100 ml. A total of 200 presumptive E. coli isolates were subjected to screening by conventional PCR in which (29%) of the wwtp-M isolates were positively identified as E. coli, (16%) of the wwtp-K, (22%) of the wwtp-Q and (34%) of the wwtp-E isolates were positively confirmed as E. coli. A total of 100 randomly selected E. coli isolates were characterised into different pathotypes. (16%) of positive isolates were detected as EPEC and 11% were detected as UPEC strains. There was no detection for the ETEC strains. Antibiotic susceptibility patterns of E. coli strains showed high levels of resistance to Penicillin G, Erythromycin, Tetracycline and Sulfamethoxazole. High levels of Susceptibility were observed in antibiotics such as Chloramphenicol, Amoxicillin and Tetracycline. The results of this study reveal that the plants were above the recommended Standard limit of zero CFU/100 ml for effluents meant to be discharge into receiving water sources. This study reveals inadequacy of the plants studied to produce effluents of acceptable quality.
143

Ecotoxicological Investigations in Effluent-Dominated Stream Mesocosms

Brooks, Bryan W. 12 1900 (has links)
The University of North Texas Stream Research Facility (UNTSRF) was designed to examine contaminant impacts on effluent-dominated stream ecosystems. Stream mesocosms, fed municipal effluent from the City of Denton, TX, Pecan Creek Water Reclamation Plant (PCWRP), were treated with 0, 15 or 140 µg/L cadmium for a 10-day study in August 2000. Laboratory toxicity test and stream macroinvertebrate responses indicated that cadmium bioavailability was reduced by constituents of effluent-dominated streams. The Biotic Ligand Model (BLM) for Cd was used to predict a 48 hour Cd EC50 for Ceriodaphnia dubia of 280 µg/L in these effluent-dominated streams. This value is higher that an EC50 of 38.3 µg/L Cd and a 7-day reproduction effect level of 3.3 µg/L Cd generated for C. dubia in reconstituted laboratory hard water. These results support use of a cadmium BLM for establishing site-specific acute water quality criteria in effluent-dominated streams. Although not affected by 15 µg/L treatments, organisms accumulated Cd in 15 µg/L treated streams. Hence, over longer exposure periods, Cd accumulation may increase and a no effect level may be lower than the observed 10-day no effect level of 15 µg/L. A toxicity identification evaluation procedure was utilized with in vitro and in vivo bioassays to identify estrogenic compounds in PCWRP effluent, previously identified to seasonally induce vitellogenin (VTG) in male fathead minnows. Steroids, nonylphenol ethoxylate metabolites, and other unidentified compounds were identified as causative effluent estrogens. These findings suggest that in vivo VTG bioassays should be used to confirm in vitro Yeast Estrogen Screening assay activity when effluents are fractionated or screened for estrogenicity. A subsequent 90-day cadmium study was initiated to assess long-term effluent and cadmium effects on fish endocrine function. Juvenile fathead minnows were placed in UNTSRF pool sections of replicate streams treated with 0, 5, 20 or 80 µg/L Cd. Male VTG was induced at each treatment level, indicating that PCWRP effluent was estrogenic during fall 2001. 20 and 80 µg/L Cd treatments reduced male circulating estradiol levels and critical swimming performance. Future studies are needed to assess impacts of environmental estrogen exposure on fish calcium metabolism and vertebral integrity.
144

Concentrations of Triclosan in the City of Denton Wastewater Treatment Plant, Pecan Creek, and the Influent and Effluent of an Experimental Constructed Wetland

Waltman, Elise Lyn 08 1900 (has links)
The Pecan Creek Waste Reclamation Plant in Denton, Texas, an activated sludge WWTP, was sampled monthly for ten months to determine seasonal and site variation in concentrations of triclosan (5-chloro-2-(2,4-dichlorophenoxy)phenol), an antibacterial additive. SNK separation after the highly significant ANOVA on ranked data were: summer = fall > winter = spring and influent > downstream = effluent = wetland inflow > wetland outflow (a=0.05). After the plant converted to ultraviolet disinfection, measurements were made before and after the UV basin to determine if significant amounts of triclosan were converted to dioxin. Percent loss at each of the treatment steps was determined. Concentrations of triclosan in the downstream site were below the published NOEC for the most sensitive species.
145

Assessing the Effects of a Municipal Wastewater Treatment Plant Effluent on Zooplankton, Phytoplankton and Corbicula Flumina in a Constructed Wetland

Hymel, Stephanie Ramick 05 1900 (has links)
Wetland wastewater treatment offers low-cost, energy efficient alternatives to conventional wastewater technologies. In this study, an artificial wetland was constructed at the City of Denton, Texas Pecan Creek Water Reclamation Plant to facilitate diazinon removal from treated effluent.
146

An Evaluation of Fish and Macroinvertebrate Response to Effluent Dechlorination in Pecan Creek

Wise, Patricia D. (Patricia Diane) 05 1900 (has links)
This study evaluated the effects of chlorinated effluent discharged from the City of Denton, Texas' wastewater treatment plant on Pecan Creek's fish and macroinvertebrate assemblages, and their recovery upon dechlorination. A baseline of ecological conditions was established while chlorine was present in the effluent (June 1993- October 1993), and was evaluated again after dechlorination with sulfur dioxide (October 1993-August 1994). In situ Asiatic clam and fathead minnow ambient toxicity tests, and fish and macroinvertebrate collections were used to establish this baseline for comparison to post-dechlorination results.
147

Evaluation of a Constructed Wetland to Reduce Toxicity from Diazinon at the Pecan Creek Wastewater Treatment Plant, Denton, TX

Baerenklau, Amy L. (Amy Lyn) 05 1900 (has links)
The City of Denton Pecan Creek Wastewater Treatment Facility has periodically failed effluent toxicity testing. A Toxicity Identification Evaluation has determined that Diazinon in the effluent is contributing to the observed toxicity. Chlorpyrifos is also implicated as a factor. The City of Denton constructed a half acre experimental wetland to remove Diazinon related toxicity. Results from spiking and microcosm experiments indicate that the wetland can reduce the Diazinon.
148

A Quantitative and Qualitative Bacterial Analysis of the Sewage Disposal System of Perryton, Texas

Sullivan, Troy G. 08 1900 (has links)
This investigation had for its purpose the determination of first, the inefficiency of the Perryton, Texas, sewage disposal plant proper; and second the potential effectiveness of a lagoon now used to complete the sewage purification; and consequently, offset an apparent health hazard. The problem, as pursued, has consisted of first, the collection of sewage samples from the six stations listed in Table 1 over the period of time from September 23, 1949 to May 14, 1950; second, a quantitative analysis of each sample in order to determine the number of bacterial organisms present; third, a qualitative analysis of each sample in order to determine more expecially the presence of members of the genera Aerobacter, Escherischia, Salmonella and Shigella; and fourth, an attempt to evaluate the potentialities of the natural purification factors of the lagoon.
149

Performance evaluation of pilot-scale constructed wetlands for the treatment of domestic wastewater in Addis Ababa, Ethiopia

Belachew, Mengesha Dagne 06 1900 (has links)
An experimental study was carried out to evaluate the performance of pilot scale constructed wetlands for the treatment of domestic wastewater in Addis Ababa, Ethiopia. Three parallel sets of constructed wetlands; consisting of one Horizontal Flow (HF), one Vertical Flow (VF) and one hybrid of HF and VFconstructed in series were built in Addis Ababa. The wetland systems had identical wetland fill media and macrophytes but with different wastewater flow types. The total surface area of the wetland systems was 72 m2 /24 m2 for each/ and designed to treat 3.15 m3 of domestic wastewater per day. Triplicate grab samples were taken from the influent and effluents every 15 days for one year and analyzed within 24 hours. Temperature, pH, DO and EC were measured onsite and the nutrient content of macrophytes was determined twice during the monitoring period. During the first 12 months monitoring period, the average removal efficiencies of the HFCW, VFCW and hybrid CW were: BOD (89.1%, 92.2% and 93.4%), COD (80.6%, 82.1% and 84.0%), TSS (89.1, 83.8% and 84.7%), NH4 + (58.6%, 66.2% and 65.4%), NO3 - (64.0%, 71.5% and 73.5%), TN (49.1%, 54.9% and 58.7%), PO4 3- (45.4%, 50.3% and 48.4%), TP (58.0%, 51.7% and 54.4%) and FC (98.6%, 96.6% and 96.5%), respectively. The hybrid system showed relatively higher removal efficiencies for most pollutants. Again, the wetland systems showed relatively higher percent reduction during the dry seasons /from Dec - May/. The areal removal rate constants of BOD5, TN, PO4 3- and TP were higher than the literature values while the values of COD and TSS were lower compared to the literature values. Concerning the nutrient content of the wetland plant, the average TN contents of the below-ground and above-ground plant part were 1.56% and 2.27% for the HFCW, 1.75% and 2.74% for the VFCW and 1.80% and 2.63% for the hybrid system, respectively. Meanwhile, the average TP contents of the belowground and above-ground plant part were 0.139% and 0.064% for the HFCW, 0.167% and 0.067% for the VFCW and 0.115% and 0.065% for the hybrid systems, respectively. In general, the results showed that properly designed constructed wetland systems could be used as effective wastewater treatment method in Ethiopia. / Environmental Sciences / Ph. D. (Environmental Sciences)
150

Linking institutional and ecological provisions for wastewater treatment discharge in a rural municipality, Eastern Cape, South Africa

Muller, Matthew Justin January 2013 (has links)
The Green Drop Certification Programme, launched in 2008 alongside the Blue Drop Certification Programme, aims to provide the Department of Water Affairs with a national overview of how municipalities and their individual wastewater treatment works (WWTW) are complying with licence conditions set by the National Water Act (NWA) (No. 36 of 1998; DWAF 1998) and the Water Services Act (No. 108 of 1997; DWAF 1998). By publishing the results of each municipality’s performance, the programme aims to ensure continuous improvement in the wastewater treatment sector through public pressure. The programme has been identified by this project as a necessary linking tool between the NWA and the Water Services Act to ensure protection and sustainable use of South Africa’s natural water resources. It does this through assisting municipalities to improve their wastewater treatment operations which in theory will lead to discharged effluent that is compliant with discharge licence conditions. These discharge licences form part of the NWA’s enforcement tool of Source Directed Controls (SDC) which help a water resource meet the ecological goals set for it as part of Resource Directed Measures (RDM). The link between meeting the required SDC and achieving the RDM goals has never been empirically tested. This project aimed to determine the present ecological condition of the Uie River, a tributary of the Sundays River which the Sundays River Valley Municipality (SRVM) discharges its domestic effluent into. It then determined whether the SRVM’s WWTW was complying with the General Standard licence conditions and what the impact of the effluent on the river was through the analysis of monthly biomonitoring, water chemistry and habitat data. Lastly, the project examined the effectiveness of the Green Drop Certification Programme in bringing about change in the SRVM’s wastewater treatment sector, which previously achieved a Green Drop score of 5.6 percent. It wanted to examine the underlying assumption that a WWTW which improves its Green Drop score will be discharging a better quality effluent that will help a water resource meets the RDM goals set for it. The Kirkwood WWTW did not have a discharge licence at the time of assessment and was thus assessed under the General Standard licence conditions. It was found that the Kirkwood WWTW was not complying with the General Standard discharge licence conditions in the Uie River. This was having a negative impact on the river health, mainly through high concentrations of Total Inorganic Nitrogen (TIN-N), orthophosphate and turbidity. The SRVM should see an improvement in its Green Drop score for the Kirkwood WWTW. However, the municipality showed no implementation of necessary programmes. Implementation of these programmes would help the SRVM meet the General Standard licence conditions (part of SDC) which would help the Uie River meet the RDM goals set for it.

Page generated in 0.1074 seconds