• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 11
  • 2
  • 1
  • 1
  • Tagged with
  • 17
  • 17
  • 15
  • 6
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Internal Radioactive Source Calibration of the Borexino Solar Neutrino Experiment

Back, Henning Olling 29 September 2004 (has links)
A measurement of solar neutrinos below 1 MeV of energy will further our knowledge of the neutrino's mass and mixing properties and will provide a probe to possible physics beyond the standard model of particle physics, as well as advance our understanding of energy production in the Sun. Borexino is a liquid scintillator detector that will measure the neutrino energy spectrum to the lowest energy threshold to date. It has been designed to measure the flux of the mono-energetic neutrinos produced by electron capture on 7Be in the Sun's core, which will produce a Compton-like edge in the energy spectrum. Because of the low count rate, Borexino requires extremely low backgrounds, and a good understanding of the backgrounds that do exist. Although the purification techniques used for the scintillator lowered the radioactive contaminates to levels never before achieved, cuts must still be made to the data. At Virginia Tech, we have developed an internal source calibration program that will be able to give us a thorough understanding of both the pulse shape discrimination efficiency and the energy and time response of Borexino. Energy calibration for alphas, betas, and gammas (energy scales) can be accomplished with such sources. When the calibration source is used in conjunction with an accurate source location system any spatial dependencies can be found. The system will use different types of sources at various energies to give the required information to make the cuts needed to extract believable physics from the detector. / Ph. D.
2

Development and testing of liquid to solid scintillating neutron detectors

Meier, William 27 May 2016 (has links)
The purpose of this research is to determine the feasibility of creating an affordable and durable neutron detector for usage in the field surveys, site inspections, and transportation hub monitoring. Currently, organic scintillating detectors are an established method of detecting neutrons but are either costly, fragile solids like stilbene, or flammable liquids like benzene. In this work, several scintillation mixtures were tested with a PuBe source, which emits both neutrons and gamma rays. The pulse shape discrimination method was utilized to separate the signal pulses created from the mixed radiation field of the PuBe source. Two candidate mixtures were selected for solidification with elastomers for their verified neutron detection capabilities. The solid detectors measured high energy neutrons and gamma rays from the PuBe source. The solidified detectors have a Figure of Merit for separating neutrons of 0.859 ±0.419 and cost $0.13 per gram, while commercially available stilbene separates neutrons from gammas with a Figure of Merit of 4.70 and costs $64.36 per gram. This research shows that it is feasible to create affordable solid organic scintillators sensitive to high energy neutrons.
3

An Investigation of Backgrounds in the DEAP-3600 Dark Matter Direct Detection Experiment

Veloce, LAURELLE 11 October 2013 (has links)
Astronomical and cosmological observations reveal that the majority of the matter in our universe is made of an unknown, non-luminous substance called dark matter. Many experimental attempts are underway to directly detect particle dark matter, which is very difficult to measure due to the expected low interaction rate with normal matter. DEAP-3600 is a direct dark matter search experiment located two kilometres underground at SNOLAB, in Sudbury, Ontario. DEAP-3600 will make use of liquid argon as the detector material, which scintillates as charged particles pass through. The work presented here is an investigation of expected background sources in the DEAP detector. Because DEAP-3600 is a noble liquid-based experiment, a thin film of [1,1,4,4]-tetraphenyl-[1,3]-butadiene (TPB) is coated on the detector walls to shift the scintillation peak from the UV to visible regime for detection. However, alphas passing through TPB produce scintillation signals which can mimic recoil events. Because scintillation properties can change with temperature, we have conducted an investigation of alpha-induced TPB scintillation at temperatures ranging from 300 K to 3.4 K. We were able to characterize the light yield and decay times, and demonstrated that these background events should be distinguishable from true recoil events in liquid argon, thus enabling DEAP-3600 to achieve higher dark matter sensitivity. Additionally, we investigate the performance of the liquid argon purification systems, specifically the activated charcoal used for radon filtration. Previous measurements with the DEAP prototype experiment have demonstrated the necessity of removing radon from the argon prior to filling the detector, due to the release of contaminates from the argon storage systems. Charcoal radon filters are extremely efficient, however, if the emanation rate of the charcoal is too high, there is the possibility of re-contamination. We performed a measurement of the radon emanation rate of a charcoal sample using a radon emanation and extraction system at Queens University. We demonstrated that the emanation rate of the charcoal was consistent with zero. We also show that the number of residual radon atoms which reach the detector would not be an issue for DEAP-3600. / Thesis (Master, Physics, Engineering Physics and Astronomy) -- Queen's University, 2013-10-10 18:36:40.2
4

An Analysis of the 3-He Proportional Counter Data from the Sudbury Neutrino Observatory Using Pulse Shape Discrimination

Martin, RYAN 22 September 2009 (has links)
This thesis presents an independent analysis of the data from 3-He-filled proportional counters from the third phase of the Sudbury Neutrino Observatory (SNO) data. These counters were deployed in SNO's heavy water to independently detect neutrons produced by the neutral current interaction of 8-B solar neutrinos with deuterium. Previously published results from this phase were based on a spectral analysis of the energy deposited in the proportional counters. The work in this thesis introduces a new observable based on the time-profile of the ionization in the counters. The inclusion of this observable in a maximum-likelihood fit increases the potential to distinguish neutrons from backgrounds which are primarily due to alpha-decays. The combination of this new observable with the energy deposited in the counters results in a more accurate determination of the number of neutrons. The analysis presented in this thesis was limited to one third of the data from the proportional counters, uniformly distributed in time. This limitation was imposed to reconcile different time-lines between the submission of this thesis, a thorough review of this work by the SNO Collaboration and results from an independent analysis that is still underway. Analysis of this reduced data set determined that 398 +/- 29 (stat.) +/- 9 (sys.) neutrons were detected in this reduced data-set. The number compares well to the previous analysis of the data, based only on a spectral analysis of the deposited energy, which determined that 410 +/- 44 (stat.) +/- 9 (sys.) were detected in the same time period. The analysis presented here has led to a substantial increase in the statistical accuracy. Assuming that the statistical accuracy will increase when the full data set is analyzed, the results from this thesis would bring the uncertainty in the 8-B solar neutrino flux to down 6.8% from 8.5% in the previously published results. The work from the thesis is intended to be included in a future analysis of the SNO data and will result in a more accurate measurement of the total flux of solar neutrinos from 8-B as well as reduce the uncertainty in the $\theta_{12}$ neutrino oscillation mixing angle. / Thesis (Ph.D, Physics, Engineering Physics and Astronomy) -- Queen's University, 2009-09-16 15:56:28.195
5

Characterisation of a New Type of Solid Organic Scintillator for neutron-gamma Discrimination using Pulse-Shape DiscriminationTechniques

Nishada, Qadir January 2014 (has links)
In this report the neutron-gamma discrimination capabilities of the new type of solid organic scintillator, EJ-299-33, was investigated using several pulse-shape discrimination (PSD) techniques. Among others, the analog zero-crossing method andthe digital charge-comparison and integrated-rise-time method were tested. The parameters of the digital PSD methods were optimised individually and the figure-of-merit was measured for each method and compared in different energy windows. The photoelectron yield of the setup was measured using two different photomultiplier tubes (PMT), a 3 inch diameter ET 9821 and a 5 inch diameter ET 9390KB. The highest photoelectron yield was measured with the ET 9390KB, which was the PMT used for the neutron-gamma discrimination capability measurements. In this work, four decay constants were found for the scintillator decay times. These were found by fitting average neutron and gamma-ray waveforms with the convolution of severeal exponential functions, that describes the light emission intensity of the scintillator, with an approximation of the PMT response function. Thebest agreement was found for the assumption that the scintillator light emission intensity is governed by four decay constants. The intensity of the two slowest components contain information about the incident particle.
6

Study of the pulse shape as a means to identify neutrons and gammas in a NE213 detector

Höök, Mikael January 2006 (has links)
This report describes investigations of the NE213-detector and the possibility to utilize pulse shape analysis to separate neutrons and gammas in a mixed emission field. Neutron fluxes are often contaminated with gammas, to which the detectors are sensitive. Sorting out the unwanted gamma pulses from the interesting neutrons is therefore crucial in many situations, for instance in fusion reactor diagnostics, such as for neutron cameras. This can be done based on pulse shapes, which differ for gammas and neutrons interacting in the NE213-detector. By analyzing the pulse shapes from a digital transient recorder, neutrons can be distinguished from gammas. An experiment with a Cf-252 neutron source was set up and provided data. The separation algorithm was based on charge comparison and gave good results. Furthermore the results of the pulse shape analysis were verified by TOF-measurements. The lowest permissible energy for a reasonable separation was found to be around 0.5 MeV. Some conclusions on the limitations of the equipment were also made.
7

Comparison of neutron fluence spectra measured with NE213 proton recoil spectrometer and NE230 deuteron recoil spectrometer

Masondo, Vusumuzi January 2014 (has links)
>Magister Scientiae - MSc / A (5 cm × 5 cm) cylindrical NE213 liquid organic scintillator and a (2.5 cm × 2.5 cm)cylindrical NE230 liquid organic scintillator were used as spectrometers. A series of measurements was made with both the NE213 and NE230 spectrometers, with the time-of- flight technique used for neutron energy selection. Pulse height spectra for quasi- monoenergetic neutron beams of ~5-64 MeV produced by bombarding either a (1 mm) lithium metal target, or a (10 mm) beryllium target, or a (10 mm) graphite target with 66 MeV proton beam were measured with both spectrometers. Deuteron events identified by pulse shape discrimination were selected for measurements with the NE230 spectrometer while proton events were selected for measurements with the NE213 spectrometer. Response of the scintillator to protons using NE213 and deuterons using NE230 were obtained from the measured pulse height spectra. Detector efficiency of the NE213 spectrometer as a function of neutron energy was determined for n-p elastic scattering. The detector efficiency of the NE230 was determined relative to the well-known efficiency of the NE213 spectrometer, selecting either all or n-d elastic events in the pulse height spectra measured with the NE230 spectrometer. The detection efficiency of the NE230 spectrometer was also determined from the available cross-section for n-d elastic scattering as exploratory work. Neutron fluence spectra could be determined using the appropriate neutron detection efficiency for each spectrometer and were compared with each other. The results showed good comparison and encouragement demonstrating the reliability of neutron fluence spectral measurements withthe NE230 spectrometer using the time-of-flight technique.
8

Global summation of radial frequency patterns and the effect of sudden onset glare on shape discrimination

Ekure, Edgar 12 June 2014 (has links)
ABSTRACT Global summation of radial frequency patterns and the effect of sudden onset glare on shape discrimination The purpose of this study was to provide evidence of global pooling around the circumference of the Radial frequency (RF) pattern, and to study the effect of sudden onset glare on shape discrimination. The RF stimuli were generated by the amplitude modulation of the radius of a circle which deforms them from circularity, while the cross sectional luminance profile was the fourth derivative of Gaussians (D4). The amplitude of the stimuli determines how distinct the pattern is and thus measures the degree of sensitivity while the radial frequency determines the number of lobes the pattern has. In the first part of the study, whole RF patterns (RF3 to RF16) and open component fractions (0.125, 0.25, 0.5, 0.75), which are incomplete sectors of the whole, were tested against their respective reference unmodulated patterns. Subjects were tasked with discriminating minute deviations from their reference patterns. In the second part of the study, high contrast (20 X detection threshold) RF3 and RF4 contours and equivalent low contrast (5 X detection threshold) RF3 and RF4 contours were used as stimuli. Shape discrimination threshold for the high contrast target was determined with and without sudden onset glare. The result of the first part of the study showed that threshold decreased significantly as larger component RF patterns were tested (p < 0.05). The decrease could not be accounted for by the probabilistic sampling of local filters (probability summation). The result of the second part of the study showed that shape discrimination threshold increased with sudden onset glare. The increase was even more pronounced with lower mean luminance and when smaller fractions of the contours were tested. Shape discrimination threshold was significantly higher with high contrast contours in the presence of glare than equivalent low contrast contours, indicating that the veiling luminance model alone could not account for a decrease in visual performance in this shape discrimination task.
9

Digital Signal Processing Methods for Safety Systems Employed in Nuclear Power Industry

Popescu, George January 2016 (has links)
No description available.
10

First application of CsI(Tl) pulse shape discrimination at an e^+ e^- collider to improve particle identification at the Belle II experiment

Longo, Savino 31 October 2019 (has links)
This dissertation investigates CsI(Tl) pulse shape discrimination (PSD) as a novel experimental technique to improve challenging areas of particle identification at high energy $e^+ e^-$ colliders using CsI(Tl) calorimeters. In this work CsI(Tl) PSD is implemented and studied at the Belle II experiment operating at the SuperKEKB $e^+ e^-$ collider, representing the first application of CsI(Tl) PSD at a $B$ factory experiment. Results are presented from Belle II as well as a testbeam completed at the TRIUMF proton and neutron irradiation facility. From the analysis of the testbeam data, energy deposits from highly ionizing particles are shown to produce a CsI(Tl) scintillation component with decay time of $630\pm10$ ns, referred to as the hadron scintillation component, and not present in energy deposits from electromagnetic showers or minimum ionizing particles. By measuring the fraction of hadron scintillation emission relative to the total scintillation emission, a new method for CsI(Tl) pulse shape characterization is developed and implemented at the Belle II experiment's electromagnetic calorimeter, constructed from 8736 CsI(Tl) crystals. A theoretical model is formulated to allow for simulations of the particle dependent CsI(Tl) scintillation response. This model is incorporated into GEANT4 simulations of the testbeam apparatus and the Belle II detector, allowing for accurate simulations of the observed particle dependent scintillation response of CsI(Tl). With $e^\pm$, $\mu^\pm$, $\pi^\pm$, $K^\pm$ and $p/\bar{p}$ control samples selected from Belle II collision data the performance of this new simulation technique is evaluated. In addition the performance of hadronic interaction modelling by GEANT4 particle interactions in matter simulation libraries is studied and using PSD potential sources of data vs. simulation disagreement are identified. A PSD-based multivariate classifier trained for $K_L^0$ vs. photon identification is also presented. With $K_L^0$ and photon control samples selected from Belle II collision data, pulse shape discrimination is shown to allow for high efficiency $K_L^0$ identification with low photon backgrounds as well as improved $\pi^0$ identification compared to shower-shape based methods. / Graduate

Page generated in 0.1403 seconds