• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dacriocistografia em cães com o emprego da ressonância magnética (DCG-RM) e da tomografia computadorizada (DCG-TC)

Rached, Paula Abi [UNESP] 16 January 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-01-16Bitstream added on 2014-06-13T19:01:29Z : No. of bitstreams: 1 rached_pa_dr_jabo.pdf: 3585417 bytes, checksum: 3752696fc587145466f2acf864dcc409 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Deutscher Akademischer Austauschdienst (DAAD) / A dacriocistografia convencional (DCG) é a técnica de imagem mais utilizada para a avaliação do sistema lacrimal excretor. Recentemente, DCG por ressonância magnética (DCG-RM) e por tomografia computadorizada (DCG-TC) têm sido empregadas em pacientes humanos. No entanto, em cães, os relatos de investigações sobre estas técnicas são escassos. Os objetivos, com este estudo, foram: o desenvolvimento de protocolos de RM e TC; a comparação destas técnicas para avaliação do sistema lacrimal excretar; a avaliação biométrica do ducto nasolacrimal e a apresentação da utilidade de ferramentas de reconstrução tridimensional para a visibilização do sistema lacrimal excretor em cães. Material e Métodos: DCG-RM e DCG-CT foram realizadas bilateralmente em 32 cadáveres de cães. Após canulado, o canalículo superior foi preenchido com meio de contraste (contraste iodado puro e gadolinio 1:200, para CT e RM respectivamente). Imagens transversais e tridimensionais de TC foram obtidas utilizando-se cortes de 0,8mm e 2mm de espessura. O protocolo de RM incluiu as sequências T1W/3D/FFE, T1WfTSE e PDW/TSE. Em ambas as técnicas, foram testadas as orientações perpendicular e obliqua dos cortes. Os diâmetros transversais e longitidinais e o comprimento dos ductos nasolacrimais de 23 cães foram mensurados bilateralmente. Resultados: no exame de DCG-TC, todos os componentes foram visibilizados de modo satisfatório na grande maioria dos animais. O exame de DCG-RM apresentou tempo de varredura mais longo, obtendo-se melhores resultados com a seqüência T1W/3D/FFE. As médias dos diâmetros transversais para os grupos de peso corporal 1, 2 e 3 nas três regiões avaliadas variaram entre 1,07mm e 1,09mm. As médias dos diâmetros longitudinais para as classes 1, 2 e 3 nas três regiões... / Conventional radiographic cannulation dacryocystography is the most commonly used technique for evaluallon of the nasolacrimal system. Recently, MR-DCG and CT¬DCG have been extensively employed in humans patients. Systemafic investigations of these techniques in dogs are not frequently observed in medicai literature. The objectives of this study are: 1, development of MR-DCG and CT-DCG protocols and the comparison between these techniques for the evaluation of the nasolacrimal system in dogs and 2, biometric evaluation of the nasolacrimal duct and to test the usefulness of 3D reconstruction techniques for visualization of this system in dogs. Material and Methods: MR-DCG and CT-DCG were bilaterally performed in 32 cadavers of dogs. The superior lacrimal canaliculi was canulated and contrast media injected (Imerone and Omniscan® 1:200, for CT and MR respectively). CT transverse and 3D images were obtained using 0.8 to 2mm-thick slices. MR protocol included transverse images obtained by T1W/3D/FFE, T1WfTSE and PDW/TSE sequences. For both techniques, two sfice orientations were tested: perpendicular and oblique to the hard palate. Transverse and longitudinal diameters and total length of the nasolacrimal ducts of 23 dogs were bilaterally obtained. Results: in CT scans, ali the structures could be well visualized in great majority of the dogs. MR images required longer scan time. Sequence T1W/3D/FFE offered beber results when compared to PDWTTSE and T1WTTSE. The mean longitudinal diameter of the nasolacrimal duct in weight classes 1, 2 and 3 in ali regions ranged between 1,07mm e 1,09mm. The mean transversal diameter of the nasolacrimal duct in weight classes 1, 2 and 3 in ali regions ranged between 1,34mm e 3,31 mm. The mean length of the nasolacrimal duct in weight classes 1, 2 and 3 were respecfively 70mm, 93,55mm... (Complete abstract click electronic access below)
2

Compara??o de quatro diferentes testes quantitativos de produ??o lacrimal em c?es dom?sticos. / Standardization and comparison of three different quantitative tests of tear production in dogs.

Silva, Leandro Nogueira e 19 August 2010 (has links)
Submitted by Sandra Pereira (srpereira@ufrrj.br) on 2018-09-19T16:37:55Z No. of bitstreams: 1 2010 - Leandro Nogueira e Silva.pdf: 572924 bytes, checksum: fa1675478af792ae0da5d4e17ca86504 (MD5) / Made available in DSpace on 2018-09-19T16:37:55Z (GMT). No. of bitstreams: 1 2010 - Leandro Nogueira e Silva.pdf: 572924 bytes, checksum: fa1675478af792ae0da5d4e17ca86504 (MD5) Previous issue date: 2010-08-19 / Regarding the measurement of tear production, the technique of reading tear with a cotton soaked in a pH indicator solution has proven to be advantageous compared to Schirmer Tears Test in many studies due to the smaller width of the test material and time for attaining this , which leads to less reflex tear production and a closer reading of basal tear production or real. This experiment aimed to develop a quantitative measurement equipment in tear production similar to the ZoneQuick? Menicon and improve it, establish a pattern of reading to those and evaluate their advantages and disadvantages. For that, we selected 50 beagle dogs, male and female, aged 1-8 years from the Canil do Laboratorio de Quimioterapia Experimental Parasitol?gica of UFRRJ, and produced two tests with Cotton Thread with Phenol Red and Bromocresol Green. Afterwards was made the reading standization of those three tests compared to the Schirmer tear test, getting as normal range of reading for the tests with Cotton Thread with Phenol Red 13.6 to 22.7 mm/15seg., the ZoneQuick? Menicon of between 22, 7 and 37.8 mm/15seg. and tests with Cotton Thread with the Bromocresol Green 13.7 to 22.8 mm/15seg.. Among those three tests, the ZoneQuick? showed the smallest shift in color of the indicator and the largest Cotton Thread with the Bromocresol Green which along with the smaller standard error presented by this facilitates its reading and reduces the chance of false positive or negative. In a comparison between the Schirmer Tears Test , Cotton Thread with the Bromocresol Green tests and Cotton Thread with Phenol Red latter, generated less reflex tear production, with a reading closer to the real. / Em rela??o ? mensura??o da produ??o lacrimal, a t?cnica de leitura lacrimal com o fio de algod?o embebido em uma solu??o indicadora de pH vem se mostrando vantajosa em rela??o ao Teste Lacrimal de Schirmer I (TLS I) em diversos estudos, devido ? menor largura do material de teste e tempo de realiza??o deste, o que leva a uma menor produ??o lacrimal reflexa e uma leitura mais pr?xima da produ??o lacrimal basal ou real. Este experimento teve como objetivos, testar diferentes tipos de fios e avaliar qual o mais indicado a realiza??o dos testes, desenvolver um material de medi??o quantitativo da produ??o lacrimal de fio impregnado com vermelho fenol, testar outro indicador de pH, estabelecer um padr?o de leitura para estes e o ZoneQuick? da Menicon e compar?-los ao TLS I avaliando suas vantagens e desvantagens. Para isto, foram selecionados 50 c?es da ra?a Beagle, machos e f?meas, com idade variando de 1 a 8 anos do Canil do Laborat?rio de Quimioterapia Experimental Parasitol?gica da UFRRJ, e produzidos dois testes com Fio de Algod?o impregnados com Vermelho Fenol ou Verde de Bromocresol. Em seguida foi feita a padroniza??o da leitura dos tr?s testes em compara??o ao TLS I, obtendo-se como faixa normal de leitura para o Teste de Fio de Algod?o com Vermelho Fenol de 13,6 a 22,7 mm/15seg., o ZoneQuick? da Menicon entre 22,7 e 37,8mm/15seg. e o Teste de Fio de Algod?o com Verde de Bromocresol de 13,7 a 22,8 mm/15 seg.. Dentre os tr?s testes, o ZoneQuick? apresentou a menor viragem na cor do indicador e o Teste de Fio de Algod?o com Verde de Bromocresol a maior o que, juntamente com o menor erro padr?o por este apresentado, facilita sua leitura e reduz a chance de falso positivo ou negativo. Na etapa de compara??o entre os TLS I, Fio de Algod?o com Verde de Bromocresol e Fio de Algod?o com Vermelho Fenol este ?ltimo gerou menor produ??o lacrimal reflexa, com uma leitura mais pr?xima da real.

Page generated in 0.0418 seconds