11

Estudo do fluxo de potência de um gerador de indução de dupla alimentação atuando em um sistema de geração eólio-elétrica / Study of variation of power flow of a doubly-fed induction generator acting on a wind power generation system

Natália Moreira Jacob 03 April 2013 (has links)
A captação de energia eólica tem sido alvo de estudos em todo o mundo nas últimas décadas devido aos incentivos pela busca por geração de energia por meio de fontes alternativas. A configuração mais utilizada atualmente são as turbinas de três pás com eixo horizontal, upwind, operando com velocidade variável com limitação de potência por variação de passo, e utilizando o gerador de indução de dupla alimentação. A operação em velocidade variável com atuação no ângulo de passo permite a máxima captação de energia para as diferentes velocidades de vento, enquanto evita que a turbina ultrapasse o seu valor nominal de potência. O uso de conversores permite o controle das correntes do rotor, variando sua velocidade, e o controle da potência reativa de estator, e a montagem do tipo back-to-back permite que o fluxo de energia do rotor flua para a rede ou da rede. A modelagem matemática do sistema foi toda referenciada no referencial síncrono com notação vetorial e orientação de fluxo de rede, simplificando os modelos matemáticos. Para a montagem dos controladores foi utilizado o método de Controle de Modelo Interno e de Resistência Ativa. A montagem de todo o sistema para simulação foi realizada no Matlab/Simulink, e seu desenvolvimento é mostrado no decorrer do trabalho. Este trabalho analisa o fluxo de energia do sistema, desde a energia captada pelo vento até a energia entregue à rede. Para isso, são feitas análise dos fluxos das potências ativa e reativa do sistema, para fator de potência unitário, indutivo e capacitivo e para os mais recorrentes comportamentos do vento. Também são feitas análises a respeito dos regimes de operação do sistema, definidos a partir da relação entre os fluxos de potência, concluindo que a máquina poderá operar como gerador ou motor, devido principalmente à intensidade da variação do vento. / The use of wind energy has been the subject of studies around the world in recent decades due to the incentives to search for power generation through alternative sources. The most widely used configuration has been the three blades with horizontal axis and upwind turbine, operating in variable speed with power limitation by varying the pitch angle, and using the doubly fed induction generator configuration. The variable speed operation with power limitation enable for maximum energy harvesting for different wind speeds and prevents the turbine exceeds its nominal power. The use of converters allows for control of the rotor currents, varying the speed, and stator reactive power, and assembling type back-to-back allows for the rotor energy flux to flow into and out of the grid. Mathematical modeling of the whole system was referenced in the synchronous reference frame with vector notation and oriented by the grid flux, simplifying the mathematical models. For installation of the drivers, were used the Internal Model Control and Active Damping methods. The assembly of the entire system for simulation was conducted on Matlab / Simulink, and its step to step is shown in this work. This study analyzes the energy flow of the system, from the energy harvest from de wind to the energy delivered to the grid. To reach this, flow analysis of active and reactive power of the system is done, using unity, inductive and capacitive power factor, for the most recurrent wind behaviors. Analysis are made about the operation regimes of the system, defined as the relationship between the power flows, concluding that the machine can operate as a generator or motor, mainly due to the variation of the wind intensity.
12

Ajuste de parâmetros de controladores suplementares (POD) através de redes neurais artificiais em dispositivos FACTS TCSC e SSSC

Menezes, Maxwell Martins de [UNESP] 19 November 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-11-19Bitstream added on 2014-06-13T18:49:32Z : No. of bitstreams: 1 menezes_mm_me_ilha.pdf: 769292 bytes, checksum: 4b80be15a6104228fa9612312498644f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta estudos referentes à estabilidade a pequenas perturbações do SEP, considerando a atuação de FACTS para o amortecimento das oscilações eletromecânicas de baixa frequência. São abordados os dispositivos FACTS TCSC (Thyristor Controlled Series Capacitor) e o SSSC (Static Synchronous Series Compensator). É realizada a representação e modelagem dos dispositivos FACTS no SEP inserindo no Modelo Sensibilidade de Potência. Para melhorar o desempenho do SEP no que se refere à estabilidade a pequenas perturbações, controladores suplementares são propostos para aumentar o desempenho dos dispositivos TCSC e SSSC, introduzindo o amortecimento necessário ao SEP. Adicionam-se os controladores suplementares POD no modelo modificado para os dispositivos TCSC e SSSC para verificar sua atuação. Para encontrar a melhor localização para instalação dos dispositivos é usado a teoria dos resíduos. Esta mesma teoria é usada também para o ajuste dos parâmetros dos controlares juntamente com outro ajuste feito através de Redes Neurais Artificiais (RNA), que é proposto como alternativa de comparação ao método dos resíduos. Simulações são efetuadas em um sistema teste simétrico para se verificar resultados e a eficácia do controlador POD (parâmetros ajustados pela RNA proposta), acoplados aos dispositivos FACTS, na manutenção da estabilidade a pequenas perturbações do SEP. Palavras-chave: Controladores POD. Estabilidade de sistema de potência. Redes neurais artificiais. TCSC e SSSC / This work presents studies referred to short term Electric Power System (EPS) perturbations, considering the actuation of FACTS devices for low frequency electromechanical oscillation damping. The devices considered are: FACTS TCSC (Thyristor Controlled Series Capacitor) and the SSSC (Static Synchronous Series Compensator). It is representation and modeling FACTS devices in the EPS inserting in the Power Sensitivity Model. To improve the performance of the EPS considering the short term perturbations, additional controllers are proposed to increase the performance of the TCSC and SSSC devices, introducing the necessary damping to the EPS. The additional POD controller is added to the modified model for TCSC and SSSC devices to verify the acting. The residual theory is used to find the best location to install the devices. The same theory is used to adjust the parameters of the controllers and an adjustment with Artificial Neural Networks (ANN) is proposed as an alternative to the residual method. Simulations are effectuated for a symmetric test system to verify the efficiency of the POD controller (parameters adjusted by the ANN proposed), coupled with the FACTS devices, to maintain the stability considering the short term perturbations
13

Projeto e avaliação experimental de uma estratégia baseada em análise intervalar aplicada ao projeto de estabilizador de sistemas de potência robusto implementado em um sistema de geração de 10KVA

COSTA, Cleyson Amorim 12 1900 (has links)
Submitted by Cleide Dantas (cleidedantas@ufpa.br) on 2014-03-07T15:58:58Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2014-05-15T12:54:23Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) / Made available in DSpace on 2014-05-15T12:54:23Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ProjetoAvaliacaoExperimental.pdf: 1801259 bytes, checksum: 4031abdf53d2619b2e814c79172b0343 (MD5) Previous issue date: 2013 / Neste trabalho, são apresentados a metodologia de projeto e resultados de testes experimentais de um estabilizador de sistema de potência (ESP), implementado em um sistema de geração em escala reduzida de 10 kVA, localizado no Laboratório de Controle e Sistema de Potência (LACSPOT) da Universidade Federal do Pará (UFPA). O projeto do ESP é baseado em uma estratégia de controle robusto com ênfase em incertezas paramétricas estruturadas, as quais são tratadas com ferramentas da teoria de análise intervalar. Estas incertezas são decorrentes de mudanças do ponto de operação do sistema, que provocam variações nos parâmetros de um modelo matemático linearizado referente ao comportamento dinâmico do sistema elétrico de potência no referido ponto de operação. Para o projeto do ESP robusto intervalar, são realizados uma serie de ensaios experimentais com o propósito de estimar os parâmetros de modelos linearizados da planta, representando satisfatoriamente a dinâmica dos modos poucos amortecidos do sistema de geração interligado. O método de identificação é baseado em técnica de identificação paramétrica, baseado em mínimos quadrados. A partir de um conjunto de dados de entrada e saída, para cada ponto de operação, um modelo linear, do tipo auto-regressivo com entrada exógenos (ARX), estimado para fim de uso do projeto do ESP. Por fim, uma série de testes experimentais é realizada no sistema de geração interligado a rede elétrica local, com o propósito de verificar a efetividade da técnica de controle robusto intervalar proposta para a sintonia do ESP. A partir da análise da função custo do sinal de erro de desvio de potência elétrica na saída do gerador síncrono e a função custo do sinal de controle do ESP comprova-se experimentalmente o bom desempenho obtido pela técnica de controle proposta em comparação com uma técnica de controle clássica. / In this paper, are presented the design methodology and the experimental test results of a power system stabilizer (PSS), implemented in a small-scale generation system of 10 kVA, located in the Control and Power System Laboratory (LACSPOT) at the Para Federal University (UFPA). The PSS design is based on a robust control strategy with emphasis on the structured parametric uncertainties, which are treated with tools of the interval analysis theory. These uncertainties are arising from the system operation point, which cause variations in the parameters of a linearized mathematical model referent on the dynamic behavior of the power electric system in the operation point. For the interval robust PSS design, are performed experimental tests with the purpose of estimating the linearized plant models parameters, representing the low damped modes dynamic of the interconnected generation system. The identification method is based on parametric identification technique based on least squares. From a set of input and output data, for each operation point, a ARX linear model is estimated with the purposed of the PSS design. Finally, a set of experimental tests is performed in the interconnected generation system, with the purpose of analyze the effectiveness of the interval robust control technique proposed to the PSS design. From the analysis of the active power deviation signal cost function at the synchronous generator terminal and the PSS control signal cost function, proves experimentally the good performance achieved by robust control technique proposed in comparison with a classic control technique.
14

Análise da operação de sistemas de potência isolados para plataformas flutuantes / Analysis of isolated power systems operation for floating platforms.

Almeida, Bruno de 29 July 2019 (has links)
Este trabalho apresenta a modelagem do sistema elétrico de potência de uma plataforma de perfuração dotada de sistema de posicionamento dinâmico. Para tanto, inicialmente são apresentados os conceitos fundamentais de tais unidades, servindo como base teórica e justificando a necessidade de tal estudo. Posteriormente, são apresentados de forma mais detalhada os sistemas de propulsão e geração com as respectivas estratégias de controle. Para a propulsão, estes são acionados por motores de indução trifásicos tendo velocidade controlada a partir da estratégia Direct Torque Control utilizando inversores de três níveis. Para a geração, são utilizados motores diesel como máquinas primárias acoplados a geradores síncronos trifásicos, juntamente com seus respectivos reguladores de velocidade e de tensão. Primeiramente, a operacionalidade destes modelos propostos é confirmada a partir de simulações no programa computacional MATLABR®, utilizando-se a ferramenta gráfica Simulink. Na sequência, a modelagem do sistema de potência completo é obtida no mesmo programa computacional, onde são incluídos os devidos cabeamentos, transformadores e cargas dinâmicas representando os equipamentos de perfuração e de baixa tensão. Utilizando-se de patamares de carga e comandos de velocidade de propulsores obtidos de uma plataforma real em operação de perfuração são realizadas simulações neste sistema completo, tanto com os barramentos de alta tensão interligados quanto segregados. Dentre os resultados obtidos, observa-se que os controles de tensão e de frequência são adequados, além da correta divisão de carga entre geradores a partir do método droop compensado. Por fim, com o intuito de mostrar a potencialidade do sistema obtido, são realizadas análises de curto-circuito mantendo os barramentos de alta tensão interligados, onde é possível observar a propagação da queda de tensão quando a falta ocorre em um barramento de baixa tensão, além das consequências para todo o sistema quando tais faltas são aplicadas no nível de alta tensão. / This work presents the electrical power system modeling of a drilling rig equipped with a dynamic positioning system. Initially, fundamental concepts of such units are presented, bringing a theoretical basis and justifying the need for this study. Subsequently, the propulsion and generation systems as well as their respective control strategies are presented in detail. In regard to the thrusters, they are driven by three-phase induction motors and their speed are controlled by Direct Torque Control strategy using three-level inverters. In respect of the generation system, the prime movers are modeled as diesel engines coupled to three-phase synchronous generators, in addition to their respective speed and voltage regulators. Firstly, the functionality of the proposed models is confirmed by simulations in MATLABR® using Simulink graphical tool. After, the modeling of the complete power system is obtained on the same software, which considers the inclusion of appropriate wiring, transformers and dynamic loads representing the drilling and low voltage equipment. By using load levels and thruster speed commands from an actual vessel during a drilling operation, simulations are carried out at the complete system, considering the high voltage busbars at either connected or segregated configuration. Among the obtained results, it is possible to observe suitable voltage and frequency controls, besides the correct generators load sharing in compensated droop mode. Lastly, to present the potentiality of the obtained system, a short-circuit analysis is performed with the high voltage busbars connected, where it is noticed the means of the voltage drop propagates through the system when the fault occurs at a low voltage busbar, besides the consequences when similar faults are applied at the high voltage level.
15

Impacto da representação da rede elétrica no planejamento da operação de médio prazo

Souza, Heverton Reis 28 February 2014 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-02-11T12:29:20Z No. of bitstreams: 1 hevertonreissouza.pdf: 2039435 bytes, checksum: 82a19bf494e9ac400021280fb64ec1ae (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Renata, bom dia! Por favor, confirme se não tem acento no Júnior: Silva Junior, Ivo Chaves da on 2016-02-26T11:58:58Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-02-26T12:02:02Z No. of bitstreams: 1 hevertonreissouza.pdf: 2039435 bytes, checksum: 82a19bf494e9ac400021280fb64ec1ae (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-03-03T13:38:08Z (GMT) No. of bitstreams: 1 hevertonreissouza.pdf: 2039435 bytes, checksum: 82a19bf494e9ac400021280fb64ec1ae (MD5) / Made available in DSpace on 2016-03-03T13:38:08Z (GMT). No. of bitstreams: 1 hevertonreissouza.pdf: 2039435 bytes, checksum: 82a19bf494e9ac400021280fb64ec1ae (MD5) Previous issue date: 2014-02-28 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O Sistema Interligado Nacional (SIN) possui características peculiares que o torna diferente de qualquer outro no mundo, como por exemplo, predominância de usinas hidrelétricas e uma extensa rede de transmissão. Estas características, aliadas a incerteza nas afluências futuras, conduz a necessidade da realização de vários estudos na área de planejamento da operação. O planejamento da operação energética tem por objetivo determinar metas de geração hidráulica e térmica, de forma a atender o mercado consumidor de energia, com confiabilidade e economicidade, utilizando da melhor forma possível os recursos energéticos disponíveis. Para este propósito são utilizados modelos matemáticos que buscam a minimização do custo total esperado de operação do sistema, dentro de um determinado horizonte de planejamento, utilizando diferentes níveis de detalhamento. O objetivo principal deste trabalho é avaliar alguns impactos da modelagem do sistema elétrico no problema de planejamento da operação de médio prazo. Neste sentido, o sistema de transmissão é representado em sua forma completa, através de equações não lineares que modelam os fluxos de potência ativa e reativa em cada circuito que compõe o sistema elétrico. Além disso, são considerados os limites de tensão nas barras, assim como o limite de carregamento dos circuitos para cada patamar de carga. As usinas hidrelétricas e termelétricas são representadas de forma individualizada, e a função de produtibilidade é modelada através de polinômios de quarto grau. O modelo proposto utiliza Funções de Custo Futuro (FCF) pré-calculadas por um programa de planejamento da operação de médio/longo prazo, baseado em sistemas equivalentes de energia. Neste trabalho foram utilizadas as FCF produzidas pelo programa Modelo de Despacho Hidrotérmico (MDDH), desenvolvido pela UFJF. Entretanto, é importante destacar que outro modelo de decisão estratégica, baseado em sistemas equivalentes de energia, poderia ser adotado para gerar as FCF utilizadas neste trabalho. A metodologia proposta neste trabalho foi avaliada através do estudo de casos tutoriais e de médio porte, objetivando demonstrar os impactos da representação do sistema de transmissão no custo total esperado de operação do sistema e diferenças na estratégia de operação do mesmo. / The Brazilian Interconnected System has unique characteristics that make it different of any other in the world, such as predominance of hydroelectric power plants and an extensive transmission system. These features, combined with uncertainty in future inflows, leads to necessity of conducting several studies on planning of the operation. The energy operation planning aims to determine targets for hydraulic and thermal generation to meet the consumer energy market with reliability and economy, as well as possible using the available energy resources. For this purpose mathematical models that aims to minimize the expected total cost of the system operation, within a given planning horizon, using different levels of detail are used. The main objective of this work is to evaluate some impacts of the transmission system modeling in the long-term operation planning problem. In this sense, the transmission system is included in its complete form, using nonlinear equations that model the active and reactive power flow in the electrical system. In addition, some operation limits are considered, such as bus voltage limits and power flow limits in the transmission lines and transformers, for each load level. The hydroelectric and thermoelectric plants are represented in an individual form and the producibility function is modeled by fourth degree polynomials. The proposed model uses cost-to-go functions calculated from a long term operation planning program based on equivalent energy systems. In this work the cost-to-go functions produced by MDDH program were used. This program was developed by the Federal University of Juiz de Fora (UFJF). However, it is important to point out that any other model of strategic decision, based on equivalent energy systems, could be used to generate the cost-to-go functions. The proposed methodology is evaluated and validated through the study of medium scale systems and tutorial systems. The main objective is to demonstrate the impact of the detailed transmission system modeling in the total system operating expected total cost and identify differences in operation strategy.
16

Aplicação do algoritmo genético adaptativo com hipermutação no ajuste dos parâmetros dos controladores suplementares e dispositivo FACTS IPFC /

Cordero Bautista, Luis Gustavo January 2019 (has links)
Orientador: Percival Bueno de Araujo / Resumo: As perturbações ou variações de carga produzem oscilações eletromecânicas que devem ser amortecidas o mais rápido possível para garantir confiabilidade e estabilidade da rede. Neste trabalho apresenta-se uma análise do dispositivo FACTS Interline Power Flow Controller (IPFC) e o controlador Proporcional Integral (PI) no gerenciamento dos fluxos de potência e a influência dos Estabilizadores do Sistema de Potência (ESP) e do IPFC Power Oscillation Damping (POD) sobre a estabilidade do sistema elétrico de potência. Neste trabalho enfoca-se nos estudos de estabilidade a pequenas perturbações usando um Algoritmo Genético Adaptativo com Hiper-mutação (AGAH) para ajustar os parâmetros dos controladores suplementares de amortecimento, o Estabilizador de sistema de potência (ESPs) e o Power Oscillation Damping (POD) em forma coordenada. O AGAH tem como objetivo encontrar os parâmetros ótimos do controlador para melhorar o amortecimento fraco das oscilações de baixa frequência locais e inter-área. Neste trabalho representa-se o sistema de elétrico de potência com a inclusão do dispositivo Interline Power Flow Controller com o modelo de sensibilidade de corrente (MSC). Considera-se como sistema teste o sistema Simétrico de Duas Áreas e o sistema New England como o intuito de avaliar o algoritmo proposto. As simulações são feitas no ambiente do MatLab. Por fim, apresenta-se a comparação do algoritmo genético com o desempenho do algoritmo proposto. / Abstract: Small-magnitude disturbances happen to produce electro-mechanical oscillations which should be damped as quickly as possible to ensure reliability and stability of the network. This work presents an analysis of Interline Power Flow Controller (IPFC) FACTS device and PI controller to control and manage power flow and also how Power System Stabilizers and IPFC Power Oscillations Damping (POD) controller influence over an electric power system stability. This work focuses on small-signal stability studies using an Adaptive Genetic Algorithm with Hyper-mutation (AGAH) in order to tune controller parameters in a coordinated way ensuring proper damping. AGAH aims to find optimal controller parameters to enhance the poor damping of local and inter-area low frequency oscillations. This works represents the electric power system and Interline Power Flow Controller device by a current sensitivity model (CSM). This paper considers two areas 14 bus symmetrical power system and New England power system in order to assess proposed algorithm. Coding and Simulations take place in MatLab platform. AGAH and GA get compared by time convergence and performance. This paper shows AGAH is an interesting optimization technique which outweighs GA. / Mestre
17

Avaliação da segurança de sistemas de potência para múltiplas contingências usando árvore de decisão multicaminhos

OLIVEIRA, Werbeston Douglas de 15 September 2017 (has links)
Submitted by Carmen Torres (carmensct@globo.com) on 2018-02-09T18:08:56Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AvaliacaoSegurancaSistemas.pdf: 3858130 bytes, checksum: 2cbcf782498880ce489e50eb58e31bf7 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2018-02-16T13:42:52Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AvaliacaoSegurancaSistemas.pdf: 3858130 bytes, checksum: 2cbcf782498880ce489e50eb58e31bf7 (MD5) / Made available in DSpace on 2018-02-16T13:42:52Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AvaliacaoSegurancaSistemas.pdf: 3858130 bytes, checksum: 2cbcf782498880ce489e50eb58e31bf7 (MD5) Previous issue date: 2017-09-15 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Eletronorte - Centrais Elétricas do Norte do Brasil S/A / A busca de formas eficazes para promover a operação segura de sistemas de potência e aumentar a compreensão dos operadores tem encorajado a pesquisa contínua de novas técnicas e métodos que possam ajudar nessa tarefa. Nesta tese, propõe-se uma abordagem para avaliar a segurança da operação de sistemas de potência para múltiplas contingências usando a técnica árvore de decisão multi-caminhos ou (MDT, do inglês “Multiway Decision Tree”). A MDT difere de outras técnicas de árvore de decisão por estabelecer, na etapa de treinamento, um valor de atributo categórico por ramo. Essa abordagem propõe o uso de topologias (contingências) como atributos categóricos. Desta forma, a MDT melhora a interpretabilidade em relação ao estado operacional do sistema de potência, pois o operador pode ver claramente as variáveis críticas para cada topologia, de modo que as regras da MDT possam ser usadas no auxílio à tomada de decisão. Essa abordagem proposta foi utilizada para avaliação da segurança em dois sistemas testes, o sistema IEEE 39 barras e o sistema da parte do Norte do Sistema Interligado Nacional (SIN), sendo que este último foi testado com dados reais de um dia de operação. A técnica proposta baseada em MDT demonstrou bom desempenho, utiliando um conjunto de regras simples e claras. Também foi realizada uma comparação dos resultados obtidos com outras técnicas baseadas em árvores de decisão e verificou-se que o MDT resultou em um procedimento mais simples para a classificação de segurança dos sistemas com boa precisão. / The search for effective ways to promote the secure operation of power systems and to increase its understanding by operators has encouraged continuous research for new techniques and methods that can help in this task. In this paper, it is proposed an approach to assess power system operation security for multiple contingencies using a multiway decision tree (MDT). The MDT differs from other decision tree techniques for establishing, in the training step, one value of the categorical attributes by branch. This approach proposes the use of topologies (contingencies) as categorical attributes. In this way, it improves interpretability regarding the power system operational state, as the operator can see clearly the critical variables for each topology, such that the MDT rules can be used in aiding the decision-making. This proposal was used for security assessment of two test systems, the IEEE 39-bus system and the Northern part of the Brazilian Interconnected Power System (BIPS), and BIPS was tested with real data from one day operation. The proposed MDT-based technique demonstrated superior performance, with a set of simple and clear rules. It was also performed a comparison of the obtained results with other techniques based on DT and it turned out that MDT has resulted in a simpler procedure for power system security classification with good accuracy.