• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • Tagged with
  • 9
  • 9
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Climatização na pré-ordenha de vacas da raça girolando e seus efeitos na produção e qualidade do leite e no comportamento animal / Cooling of pre-milking girolando cows and its effect production and quality of milk and animal behavior

ALMEIDA, Gledson Luiz Pontes de 18 December 2009 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2016-10-05T10:46:16Z No. of bitstreams: 1 Gledson Luiz Pontes de Almeida.pdf: 4340991 bytes, checksum: a8cbabb205582862b02b35cb5ba4871b (MD5) / Made available in DSpace on 2016-10-05T10:46:17Z (GMT). No. of bitstreams: 1 Gledson Luiz Pontes de Almeida.pdf: 4340991 bytes, checksum: a8cbabb205582862b02b35cb5ba4871b (MD5) Previous issue date: 2009-12-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study was conducted to evaluate and quantify the effects of cooling of cows in the pre-milking stable waiting pen on milk production, milk composition, animal behavior, physiological state, thermal environmental adaptation and the cost-benefit of the Adiabatic Evaporative Cooling System (AECS). The research was conducted on a dairy farm producing type B milk located in the state of Pernambuco, Brazil. Sixteen multiparous lactating Girolando cows were used having a genetic composition of 7/8 Holstein-Zebu and an average production of 18 kg of milk per animal per day, divided into four groups with four evaluation periods. A (4x4) Latin square design was used. The Tukey test (P <0.05) was utilized for comparison of the means. The experiment was conducted during the summer season (February-March 2009) and lasted 56 days. The treatments consisted of different periods of exposure (0, 10, 20 and 30 min.) of the animals to the AECS in the pre-milking stable waiting pen before the morning milking sessions (5 to 5:30 a.m.) and the afternoon sessions (2:00 to 2:30 p.m.). Milk production was recorded daily and the collection of samples for analysis of its components was performed twice for each of the 4 study periods. The respiratory rate (RR), rectal temperature (RT) and temperature of the coat (TC) were taken twice during each study period, measured before and after cooling on alternating days and did not coincide with the behavioral assessment days. All animals of each treatment wereobserved at 10 minute intervals, from 7a.m. to 1p.m. and from 3p.m. to 5 p.m. Environmental data consisting of dry bulb temperature (DBT, ºC), relative humidity (RH, %) and black globe temperature (BGT, ºC) were recorded every minute during the time of exposure of animals to the cooling system in the stable waiting pen and out in the external environment using the HOBO® data logger. Wind speed was recorded usingan anemometer at all of the treatment intervals. The thermal efficiency of the system was determined by using the Temperature and Humidity Index (THI), the Wet Bulb Globe Temperature (WBGT), the Radiant Thermal Load (RTL) and enthalpy (h). Exposure of the animals in the stable waiting pen to the AECS for 30 minute periods allowed the environmental variables and the comfort indices to remain below the critical upper limit of thermal comfort for the animals. The 30 minute treatment showed lower RR, TR, and TC values when compared to animals subjected to the 0 min., 10 min. and 20 min. treatments and these values were within acceptable limits. The animals in the 30 minute cooling sessions spent more time on food intake and rumination (277 and 483 observations) compared to the 0 min. treatment (248 and 438 observations), the 10 min. treatment (251 and 437 observations) and the 20 min. treatment (274 and 476 observations) respectively. The 30 min. treatment had a 4.35% increase in milk production compared to the 0 min. treatment. There was no significant effect on milk composition among the treatments. The initial purchase cost of the AECS was R$ 2,147.80, which yielded an increase in milk production of 0.765 kg per animal per day, and an increase in monthly revenue of approximately R$ 1,266.84. Comparing the 0 min. and 30 min. cooling periods, the AECS showed itself to be a profitable investment, with a return on the invested capital within 58 days. / O presente trabalho foi conduzido com o objetivo de avaliar e quantificar os efeitos da climatização na pré-ordenha sobre a produção e composição do leite, comportamento animal, estado fisiológico, condicionamento térmico ambiental e relação custo/benefício do sistema de resfriamento adiabático evaporativo (SRAE). A pesquisa foi realizada em uma fazenda comercial de produção de leite tipo B, localizada no interior do Estado de Pernambuco. Foram utilizadas 16 vacas, multíparas de composição genética 7/8 Holandês-Gir em lactação, com produção média de 18 kg de leite animal-1 dia-1, distribuídas em quatro grupos, com quatro períodos de avaliação, adotando-se o delineamento em quadrado latino (4x4) e para comparação entre as médias foi utilizado o teste de Tukey (P<0,05). O experimento foi realizado durante a estação de verão (fevereiro a março de 2009), com duração de 56 dias Os tratamentos adotados foram os diferentes tempos de exposição dos animais ao SRAE no curral de espera, 0, 10, 20 e 30 min, para a ordenha do turno da manhã (5 às 5h30min) e da tarde (14 às 14h30min), respectivamente. A produção de leite foi registrada diariamente e a coleta das amostras para análise da composição do leite foi realizada duas vezes para cada período do estudo. A freqüência respiratória (FR), temperatura retal (TR) e temperatura do pelame(TP) foram tomadas duas vezes em cada período, medidas antes e depois da climatização, em dias não consecutivos nem coincidentes com as avaliações comportamentais, observadas em todos os animais de cada tratamento, em intervalos de 10 minutos, das 7 às 13 h e das 15 às 17 h. Os dados ambientais: temperatura de bulbo seco (Tbs, oC), umidade relativa do ar (UR, %) e temperatura de globo negro (Tgn, oC) foram registrados a cada minuto, durante o tempo de exposição dos animais àclimatização no curral de espera e no ambiente externo, por meio de datalogger HOBO®. A velocidade do vento foi registrada, com o auxílio de um anemômetro, em todos os intervalos correspondentes aos tratamentos. Assim, foi possível determinar a eficiência térmica do sistema por meio do Índice de Temperatura e Umidade (ITU), do Índice de Globo Negro e Umidade (ITGU), da entalpia (h), e da Carga Térmica Radiante (CTR). A exposição dos animais no curral de espera ao SRAE, durante 30 min, permitiu manter as variáveis ambientais e os índices de conforto abaixo do limite crítico superior para o conforto térmico dos animais. O tratamento 30 min mostrou valores inferiores para FR, TR e TP, quando comparados aos obtidos nos animais submetidos aos tratamentos de 0, 10 e 20 min, permanecendo dentro dos limites normais para estas variáveis. Verificou-se maior frequência despendida com a ingestão de alimentos e ruminação (277 e 483 observações) no tratamento 30 min, comparativamente aos tratamentos 0 min (248 e 438 observações), 10 min (251 e 437 observações) e 20 min (274 e 476 observações), respectivamente. Este fato refletiu positivamente na produção de leite dos animais do tratamento 30 min, que apresentou um aumento de 4,35% na produção, quando comparado ao tratamento 0 min. Não severificou efeito significativo na composição do leite, entre os tratamentos. O custo inicial do investimento para aquisição do SRAE foi de R$ 2.147,80, o que promoveu aumento na produção de leite de 0,765 kg animal-1 dia-1, e gerou acréscimo na receita mensal de aproximadamente R$ 1.266,84, entre os tratamentos 0 min e 30 min. de climatização, evidenciando tratar-se de investimento satisfatório e lucrativo, com tempo de retorno do capital investido de 58 dias.
2

Automação do sistema de resfriamento adiabático evaporativo na pré-ordenha de vacas girolando e seus efeitos na produção de leite / Automation of the adiabatic evaporative cooling system on pre-milking of Girolando cows and their effects on milk production

SILVA, Irenilson Machado da 28 February 2011 (has links)
Submitted by (lucia.rodrigues@ufrpe.br) on 2016-10-05T11:09:35Z No. of bitstreams: 1 Irenilson Machado da Cruz.pdf: 1806575 bytes, checksum: 568635ede22f00f36549509308966d1c (MD5) / Made available in DSpace on 2016-10-05T11:09:35Z (GMT). No. of bitstreams: 1 Irenilson Machado da Cruz.pdf: 1806575 bytes, checksum: 568635ede22f00f36549509308966d1c (MD5) Previous issue date: 2011-02-28 / The objective of this study was to develop a system for monitoring and control of actuators in quanti-qualification of the effects of cooling system in the pre-milking for caw on milk production, physiological state and the efficiency of the thermal conditioning system with the use of geostatistics in a semi-intensive system of milk production. The research was conducted on a dairy farm producing type B milk located in the state of Pernambuco, 8°36'33" S, 36°37'30" W and altitude of 733 m, in January-February of 2010. The development of the controller system of the environmental variables (temperature, ºC and relative humidity of the air, RH%), comprised the steps of assembly, test and laboratory calibration and after that the validation of the equipment carried in the field. The validation step showed that the results obtained allowed that the system can be used safely, which granted the degree of automation required for the intermittent operation of cooling system in the pre-milking. The equipment showed the lower cost (R$ 325.76), when compared to other middle market (R$ 450.00). In the experimental step of the study, 16 cows producing 20 kg milk d-1 were used, adopting the Latin square design 4 x 4 and comparison between means by Tukey test (P<0.05). Different times were considered of exposure of the animals in pre-milking to the adiabatic evaporative cooling system (AECS) automated, 0, 20, 30 and 40 min. The dry bulb temperature (Tbs) and relative humidity of air (RH) were recorded every minute, which allowed determining the temperature and humidity index (THI) and the enthalpy (h). The respiratory rate (RR), rectal temperature (RT) and temperature of coat (TC) were measured before and after cooling system. The exposure of animals to 40 min of the cooling system maintained the environmental variables and the indices of comfort between the recommended limits. The physiological variables (RR, RT and TC) showed lower values when the animals were exposed to AECS for 40 min., with 3.66% increase in the milk production. The investment promoted increase in the monthly revenue of R$ 1,992.67, with a time of return on invested capital of 40 days. Knowledge of spatial variability of air temperature and the construction of maps of kriging allowed checking that the use of geostatistics has defined specific areas in the stable waiting pen (pre-milking) that were above the critical limit of animal thermal comfort. The time of exposure to cooling system for 40 min ensured the stabilization of air temperature within the thermal comfort condition for lactating cows. / Objetivou-se com esta pesquisa desenvolver um sistema de monitoramento e controle de atuadores na quanti-qualificação dos efeitos da climatização na pré-ordenha de bovinos sobre a produção de leite, estado fisiológico e a eficiência do acondicionamento térmico ambiental com o emprego da geoestatística em um sistema semi-intensivo de produção de leite. A pesquisa foi realizada em uma fazenda comercial de produção de leite tipo B, localizada no município de Capoeiras, PE, latitude de 8º36‟33” S, longitude de 36º37‟30” W e altitude de 733 m, de janeiro a fevereiro de 2010. O desenvolvimento do sistema controlador das variáveis ambientais (temperatura, oC e umidade relativa do ar, UR%) compreendeu as etapas de montagem, teste e aferição em laboratório e, posteriormente a etapa de validação do equipamento realizada no campo. A etapa de validação apresentou resultados que permitiu concluir que o sistema pode ser utilizado com segurança, o que garantiu o grau de automação necessário para o funcionamento intermitente da climatização na pré-ordenha. O equipamento apresentou custo reduzido (R$ 325,76) quando comparado a média de outros no mercado (R$ 450,00). Na etapa experimental da pesquisa, utilizaram-se 16 vacas com produção de 20 kg de leite d-1, adotando-se delineamento em quadrado latino 4 x 4 e comparação entre as médias pelo teste de Tukey (P<0,05). Foram considerados diferentes tempos de exposição dos animais na pré-ordenha ao sistema de resfriamento adiabático evaporativo (SRAE) automatizado, 0, 20, 30 e 40 min. A temperatura de bulbo seco (Tbs) e umidade relativa do ar (UR) foram registradas a cada minuto, o que permitiu determinar o índice de temperatura e umidade (ITU) e entalpia (h). A frequência respiratória (FR), temperatura retal (TR) e temperatura de pelame (TP) foram medidas antes e depois da climatização. O tempo de exposição dos animais a 40 min de climatização manteve as variáveis ambientais e os índices de conforto entre os limites recomendados. As variáveis fisiológicas (FR, TR e TP) mostraram valores inferiores quando os animais foram expostos ao SRAE por 40 min, com aumento de 3,66% na produção de leite. O investimento promoveu acréscimo na receita mensal de R$ 1.992,67 com tempo de retorno do capital investido de 40 dias. O conhecimento da variabilidade espacial do atributo temperatura do ar e a construção de mapas de krigagem possibilitaram verificar que o uso da geoestatística definiu áreas específicas no curral de espera (pré-ordenha) que estiveram acima do limite crítico de conforto térmico animal. O tempo de exposição à climatização por 40 min garantiu a estabilização da temperatura do ar dentro da condição de conforto térmico para vacas em lactação.
3

Sistema de ventilação com nebulização no frigorífico sobre o microclima do veículo transportador, respostas fisiológicas e comportamentais de suínos / Ventilation system with water misting at the commercial slaughter plant on truck microclimate, physiological and behavior response of pigs

Pereira, Thuanny Lúcia 25 January 2018 (has links)
Objetivou-se avaliar a efetividade da ventilação forçada associada à nebulização sobre as respostas comportamentais e fisiológicas de suínos mantidos dentro do veículo transportador antes do descarregamento na indústria frigorífica. Durante 6 semanas de transporte, 2 veículos pot-belly (PB) transportaram 191 suínos cada até a mesma planta frigorífica. Na chegada, ambos veículos permaneceram estacionados por 30 minutos antes da descarga. Um dos veículos PB foi posicionado ao lado do sistema de ventilação e nebulização (PBVM), enquanto o outro PB não teve acesso ao sistema de resfriamento (PBC). O tratamento (PBVM) consistiu em 10 minutos de ventilação (Espera 1); seguido de 10 minutos de ventilação e nebulização (Espera 2) e 10 minutos finais de ventilação (Espera 3). A temperatura do ar (T) e a umidade relativa (RH) foram monitorados. A frequência de suínos deitados e a frequência de acesso ao bebedouro foram calculadas. Temperaturas do trato gastrointestinal (GTT), lactato sanguíneo, hematócrito, creatina quinase e concentrações de cortisol foram avaliados. Durante a Espera 1, a ventilação forçada reduziu a temperatura do ar e o índice de temperatura e umidade no tratamento PBVM. Na Espera 3, a temperatura e o índice de temperatura e umidade foram menores (P &lt; 0.001) no tratamento PBVM comparado ao PBC, contudo a umidade relativa do ar foi maior (P &lt; 0.001). Suínos oriundos do compartimento 4 do PBVM apresentaram maior atividade durante o tempo de Espera 2 e 3, e reduzido tempo de latência para se deitar na baia do frigorífico (P &lt; 0.05). Redução no GTT dos suínos oriundos do PBC foi observada após 1 hora de período de descanso comparada ao PBVM. O percentual de hematócrito tendeu a ser maior nos suínos PBC comparado ao PBVM. O sistema de ventilação e nebulização utilizado na indústria frigorifica antes do descarregamento melhora de forma eficiente as condições internas térmicas do caminhão e consequentemente o conforto térmico dos suínos mantidos no veículo transportador, com redução na temperatura dentro dos compartimento e baixo nível de desidratação no abate. / The aim of this study was to evaluate the effectiveness of water misting with forced ventilation on a stationary trailer on internal vehicle ambient conditions, behavioral and physiological response of market pigs. During 6 weekly shipments, two identical tri-axle pot-belly (PB) trailers transported 191 pigs each (126 ± 5 kg BW) to the same slaughter plant. On arrival, both trailers were kept stationary in the yard for 30 min before unloading. One PB trailer was pulled over along a fan-misters bank (PBVM), while the other PB trailer had no access to this cooling system (PBC). The PBVM treatment consisted in 10 min of fan-assisted ventilation (wait 1) followed by 10 min of ventilation and water misting (wait 2) and final 10 min of ventilation (wait 3). The air temperature (T) and relative humidity (RH) were monitored. The frequency of lying pigs, the latency to rest and the frequency of drinking bouts were calculated. Gastrointestinal tract temperature (GTT) and exsanguination blood lactate, hematocrit, creatine kinase and cortisol concentrations were assessed. In wait 1, the application of the fan-assisted ventilation resulted in lower (P &lt; 0.05) T and THI in the PBVM. In wait 3, T and THI were still lower (P &lt; 0.001) in PBVM compared to PBC, but the RH was higher (P &lt; 0.001). Pigs from compartment 4 of PBVM had a greater (P &lt; 0.001) activity during waits 2 and 3, and a reduced latency to lie down in the lairage pen compared to the same compartment in the PBC (P &lt; 0.05). A higher (P &lt; 0.05) GTT drop was recorded until 1 h after lairage in pigs located in PBC compared to those transported in PBVM. At slaughter, hematocrit tended to be higher (P = 0.08) in blood of PBC pigs compared to PBVM. The fan-misters bank used on the PBVM vehicle sitting at the slaughter plant before unloading efficiently improves internal trailer thermal conditions and consequently thermal comfort of pigs kept in a stationary trailer, with reduced temperature within the compartments and lower dehydration condition at slaughter.
4

Avaliação de um modelo simplificado para estimativa do balanço de energia em galpões para produção de frangos de corte e zoneamento do potencial de uso do resfriamento evaporativo para a região sudeste / Evaluation of a simplified model for the estimation of the energy balance in sheds for slaughter chicken production and demarcation of the evaporative cooling usage potential for the southeast region

Silva, Mariano Pereira 27 February 2003 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-02-20T11:40:07Z No. of bitstreams: 1 texto completo.pdf: 5533181 bytes, checksum: 0ad56703e893ea0317daecbe4175aabf (MD5) / Made available in DSpace on 2017-02-20T11:40:07Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5533181 bytes, checksum: 0ad56703e893ea0317daecbe4175aabf (MD5) Previous issue date: 2003-02-27 / A avicultura brasileira é hoje a segunda do mundo, sendo superada apenas pelos Estados Unidos da América. A produção de aves de corte e de postura em alta densidade de alojamento passou a ser imperativa e, desta forma, a exigência de conforto térmico ambiental, que já havia crescido muito com o aumento da precocidade das aves, passou a ser ainda maior. Como conseqüência, a atenção ao adequado planejamento e projeto das instalações avícolas passou a ser priorizado. Os avanços nos sistemas de informações geográficas (SIG) e a maior disponibilidade de dados meteorológicos permitem que se estude sistemas de acondicionamento artificial de ambiente em função das condições climáticas de cada região. A simulação do comportamento térmico de galpões avícolas com e sem Sistemas de Resfriamento Adiabáticos Evaporativos (SRAE) permite aos tomadores de decisão avaliarem a viabilidade econômica e os custos da instalação de um empreendimento na avicultura de corte. Esta pesquisa teve como objetivo geral, avaliar a condição térmica ambiental de criação das aves, a partir de dados climáticos diários, como forma de prever perdas na produção de frango, causadas pela inadequação técnica das instalações. Foi usado o modelo desenvolvido por GATES et al. (1995), que faz um balanço térmico simplificado de um galpão avícola permitindo estimar as temperaturas e os valores de umidade relativa dentro de galpões, com e sem sistema de resfriamento adiabático evaporativo. O modelo foi validado a partir de dados coletados num galpão instalado em uma granja comercial, no município de Palotina, estado do Paraná. A referida granja adota o modelo de galpão climatizado. Foram utilizados dados da Re-análise 2 do NCEP/NCAR do período de 01.01.1980 à 31.12.2000 para a região Sudeste. Como os dados são de seis em seis horas, foram estimados os valores intermediários de hora em hora, utilizando a metodologia proposta por ZOLNIER et al. (1996). A partir dos dados do modelo foram determinados os valores de ITU (Índice de Temperatura e Umidade), com base na equação desenvolvida por DESHAZER & BECK (1988) e gerados mapas para a região Sudeste. O modelo se mostra adequado para o objetivo proposto, na forma proposta por GATES et al. (1995) para galpões com vazão mássica do ar elevada, 120,8 kg de ar por segundo ou maior. É necessário um fator de correção referente a uma série de fontes de calor desprezada pelo modelo para galpões sem uma grande vazão mássica, ou a inclusão dessas fontes. A umidade relativa elevada na região Sudeste é um limitante ao uso do sistema de resfriamento adiabático evaporativo. O mês de maior benefício empregando o sistema de resfriamento adiabático evaporativo é janeiro. Na região Sudeste a área de menor benefício é a parte central. A área que compreende a parte costeira no Rio de Janeiro e no Espírito Santo e a parte da região Sudeste fronteiriça com a Bahia é a de maior benefício dentro da região Sudeste. / The Brazilian poultry raising is, at present, the second in the world, only being surpassed by The United States of America. The slaughter and posture poultry production in high density of lodging became imperative, and, in this way, the environmental thermal comfort request, which had already grown very much with the precocity growth of the birds, started to be even greater. As a consequence, attention to the suitable planning and projecting of the poultry farming installations started to be a priority. The advances in the geographic information systems (GIS), and the greater availability of the meteorological data permit that systems of artificial conditioning of the environment according to the climatic conditions of each region could be studied. The simulation of the poultry sheds thermal behavior with and without Adiabatic Evaporative Cooling (SRAE) allow the decision makers to evaluate the economical viability and the installation costs of a poultry slaughter enterprise. The general objective of this research was to evaluate the thermal environmental conditions of bird raising, based on daily climatic data, as a way of previewing chicken production loss caused by inadequate technical installations. The model developed by GATES et. al. (1995) was used, which makes a simplified thermal balance of a poultry shed permitting the temperatures at the relative humidity values inside the sheds with and without the adiabatic evaporative cooling to be estimated . The model was validated from data collected in a shed located in a commercial poultry farm, in Palotina district, Parana state. This mentioned poultry farm adopts the climatized shed model. Data from the Re-analyses 2 of the NCEP/NCAR from the period of 01.01.1980 to 12.31.2000 for the southeast region were used. As the data are from six to six hours, the intermediary values from hour to hour were estimated using the methodology proposed by ZOLNIER et. al. (1996). With the data from the model the THI (Temperature and Humidity index) values were determined, based on the equation developed by DESHAZER & BECK (1988) and generated maps for the southeast region. The model presents to be suitable for the proposed objective in the form proposed by GATES et.al. (1995) for sheds with elevated mass flow rate of air , 120,8 kg of air per second or greater. A correlative factor referring to a series of heat resources rejected by the model for sheds without a great mass flow rate of air, or the inclusion of these resources, is necessary. The elevated relative humidity in the southeast region is a limiting to the use of the adiabatic evaporative cooling system. The month with the best benefits for using the adiabatic evaporative cooling system is January. In the southeast region the area with the lowest benefits is the central part. The area which comprises the coastal part in Rio de Janeiro and Espírito Santo states, and the southeast region bordering with Bahia state, is the one with the greater benefits in the southeast region. / Dissertação importada do Alexandria
5

Sistema de ventilação com nebulização no frigorífico sobre o microclima do veículo transportador, respostas fisiológicas e comportamentais de suínos / Ventilation system with water misting at the commercial slaughter plant on truck microclimate, physiological and behavior response of pigs

Thuanny Lúcia Pereira 25 January 2018 (has links)
Objetivou-se avaliar a efetividade da ventilação forçada associada à nebulização sobre as respostas comportamentais e fisiológicas de suínos mantidos dentro do veículo transportador antes do descarregamento na indústria frigorífica. Durante 6 semanas de transporte, 2 veículos pot-belly (PB) transportaram 191 suínos cada até a mesma planta frigorífica. Na chegada, ambos veículos permaneceram estacionados por 30 minutos antes da descarga. Um dos veículos PB foi posicionado ao lado do sistema de ventilação e nebulização (PBVM), enquanto o outro PB não teve acesso ao sistema de resfriamento (PBC). O tratamento (PBVM) consistiu em 10 minutos de ventilação (Espera 1); seguido de 10 minutos de ventilação e nebulização (Espera 2) e 10 minutos finais de ventilação (Espera 3). A temperatura do ar (T) e a umidade relativa (RH) foram monitorados. A frequência de suínos deitados e a frequência de acesso ao bebedouro foram calculadas. Temperaturas do trato gastrointestinal (GTT), lactato sanguíneo, hematócrito, creatina quinase e concentrações de cortisol foram avaliados. Durante a Espera 1, a ventilação forçada reduziu a temperatura do ar e o índice de temperatura e umidade no tratamento PBVM. Na Espera 3, a temperatura e o índice de temperatura e umidade foram menores (P &lt; 0.001) no tratamento PBVM comparado ao PBC, contudo a umidade relativa do ar foi maior (P &lt; 0.001). Suínos oriundos do compartimento 4 do PBVM apresentaram maior atividade durante o tempo de Espera 2 e 3, e reduzido tempo de latência para se deitar na baia do frigorífico (P &lt; 0.05). Redução no GTT dos suínos oriundos do PBC foi observada após 1 hora de período de descanso comparada ao PBVM. O percentual de hematócrito tendeu a ser maior nos suínos PBC comparado ao PBVM. O sistema de ventilação e nebulização utilizado na indústria frigorifica antes do descarregamento melhora de forma eficiente as condições internas térmicas do caminhão e consequentemente o conforto térmico dos suínos mantidos no veículo transportador, com redução na temperatura dentro dos compartimento e baixo nível de desidratação no abate. / The aim of this study was to evaluate the effectiveness of water misting with forced ventilation on a stationary trailer on internal vehicle ambient conditions, behavioral and physiological response of market pigs. During 6 weekly shipments, two identical tri-axle pot-belly (PB) trailers transported 191 pigs each (126 ± 5 kg BW) to the same slaughter plant. On arrival, both trailers were kept stationary in the yard for 30 min before unloading. One PB trailer was pulled over along a fan-misters bank (PBVM), while the other PB trailer had no access to this cooling system (PBC). The PBVM treatment consisted in 10 min of fan-assisted ventilation (wait 1) followed by 10 min of ventilation and water misting (wait 2) and final 10 min of ventilation (wait 3). The air temperature (T) and relative humidity (RH) were monitored. The frequency of lying pigs, the latency to rest and the frequency of drinking bouts were calculated. Gastrointestinal tract temperature (GTT) and exsanguination blood lactate, hematocrit, creatine kinase and cortisol concentrations were assessed. In wait 1, the application of the fan-assisted ventilation resulted in lower (P &lt; 0.05) T and THI in the PBVM. In wait 3, T and THI were still lower (P &lt; 0.001) in PBVM compared to PBC, but the RH was higher (P &lt; 0.001). Pigs from compartment 4 of PBVM had a greater (P &lt; 0.001) activity during waits 2 and 3, and a reduced latency to lie down in the lairage pen compared to the same compartment in the PBC (P &lt; 0.05). A higher (P &lt; 0.05) GTT drop was recorded until 1 h after lairage in pigs located in PBC compared to those transported in PBVM. At slaughter, hematocrit tended to be higher (P = 0.08) in blood of PBC pigs compared to PBVM. The fan-misters bank used on the PBVM vehicle sitting at the slaughter plant before unloading efficiently improves internal trailer thermal conditions and consequently thermal comfort of pigs kept in a stationary trailer, with reduced temperature within the compartments and lower dehydration condition at slaughter.
6

Metodologia para análise termoeconômica de sistemas de resfriamento distrital. / Thermoeconomic methodology for district cooling systems analysis.

Santos, Arthur Garuti dos 18 March 2019 (has links)
Com o constante desenvolvimento das áreas urbanas e aumento do consumo energético destinado a conforto térmico, um estudo foi realizado para formulação de uma metodologia de análise termoeconômica de sistemas distritais de resfriamento. O objetivo principal é descrever uma metodologia referente à implantação de sistemas distritais no Brasil, por sua vez, o objetivo secundário é aplicar a metodologia no estado de São Paulo, analisando as premissas utilizadas na metodologia. Primeiramente, apresentou-se uma visão geral e revisão de literatura dos sistemas de aquecimento e resfriamento distrital, indicando suas vantagens e desvantagens, bem como as diversas aplicações e desafios para sua implantação. Aplicações no cenário mundial foram expostas e analisadas, demonstrando que sua utilização em diversos países se estende por décadas. As principais vantagens observadas nas aplicações existentes estão relacionadas a maior eficiência energética e exergética global, redução das emissões de gases poluentes e confiabilidade do sistema. Por fim, a metodologia aplicada está apresentada em cinco etapas, de forma ordenada, baseando-se nas etapas de um projeto de sistemas distritais. Seu resultado é baseado em rotinas, simulações de processos e procedimentos de otimização, bem como aplicação de indicadores energéticos. Ao final das etapas e seu desenvolvimento matemático obtém-se um estudo preliminar de viabilidade da implantação de um sistema distrital. O estudo de caso apresentado aplica a metodologia para a cidade de São Paulo buscando descrever com detalhamento as premissas e etapas descritas. / The constant development of urban areas and increased energy consumption for thermal comfort encourage studies that formulate a methodology for thermoeconomic analysis of district cooling systems. The main objective is to describe a thermoeconomic methodology related to the implementation of district systems in Brazil. The secondary objective is to apply the methodology in the state of São Paulo, analyzing the premises used in the methodology. At first, an overview and literature review of district heating and cooling systems was presented, indicating their advantages and disadvantages, just as the various applications and challenges for their implementation. Applications on the world stage have been introduced and analyzed, demonstrating that their use in several countries extends for decades. The main advantages observed in the existing applications are related to global energy and exergy efficiency, reduction in greenhouse gases and reliability of the systems. Finally, the applied methodology is presented in five steps in an orderly manner based on the steps of a district system project. Its result is based on routines, process simulations and optimization procedures, as well as application of energy indicators. At the end of the steps and their mathematical development a preliminary study of the feasibility of the implantation of a district system is obtained. The present case study applies the methodology for the city of São Paulo and describe in detail the premises and steps.
7

Estudo de caso de um sistema de cogeração em uma indústria farmacêutica

Ademir Edson Fernandes 03 December 2011 (has links)
No atual período de incertezas na geração e transmissão de energia elétrica no Brasil, a utilização dos sistemas de cogeração com uso de gás natural, tornou-se uma grande oportunidade econômica, estratégica e tecnológica, para as pequenas e médias empresas, considerando a extensão e perspectivas de expansão da rede de distribuição de gás natural. Uma empresa farmacêutica para se manter competitiva e reduzir o impacto dos custos indiretos em seus produtos, necessitava aumentar sua linha de injetáveis, produzindo no Brasil alguns medicamentos que até então eram importados de filiais em outros países e para que isto fosse possível, teria de investir na construção de novos laboratórios, compra de equipamentos, aumento de utilidades para sua fabricação como vapor de água para injetáveis, sistema de HVAC para salas limpas, o que levaria a um aumento de consumo de energia, vapor, água de refrigeração. Este investimento inviabilizaria a produção desta nova linha de produtos, pois tanto o custo do investimento em novas centrais de utilidades, quanto mais o custo desta geração e sua manutenção, decretariam um fim para a esta empreita. Neste trabalho, apresentou-se uma alternativa como solução para viabilizar esta instalação, trocando-se os chillers convencionais por um chiller de absorção, que alem de consumir pouca energia elétrica utilizando a troca térmica entre brometo de lítio e vapor para gerar água de resfriamento para o sistema de ar condicionado, o sistema proposto proporcionou um aumento de fornecimento de vapor não só para alimentar o sistema de HVAC como para a produção da fabrica, anexo a esta caldeira de recuperação é proposto a instalação de uma turbina á gás com condições suficientes de gerar energia elétrica para todo o site e ainda ter condições de negociar o excedente de energia para ser vendido para a concessionária. O resultado deste sistema proposto demonstrou uma excelente eficiência, frente ao sistema convencional, o que tecnicamente se apresentou como muito viável. / In the current period of uncertainty in the generation and transmission of electric energy in Brazil, the use of cogeneration systems using natural gas, has become a great economic opportunity, strategic and technology for small and medium enterprises, considering the extent and prospects for expansion of the distribution of natural gas. A pharmaceutical company to remain competitive and reduce the impact of indirect costs in their products, needed to increase its line of injectables, producing here in Brazil some drugs that were previously imported from subsidiaries in other countries and to make this possible, would invest in building new laboratories, purchase equipment, increase of utilities for its manufacture steam as water for injection, the HVAC system for clean rooms, leading to an increased consumption of energy, steam, cooling water. This investment would make impracticable the production of this new line of products, therefore not only the cost of the investment in new central offices of utilities, the more the cost of this generation of utilities and its maintenance, would decree an end for the this take over on a contract basis. In this work, presented as an alternative solution to enable this facility, exchanging conventional chillers for an absorption chiller, which besides consume little electricity using the heat exchange between lithium bromide to generate steam and cooling water for the air conditioning system, the proposed system provided an increased supply of steam to feed not only the HVAC system for the production of manufactures, attached to this recovery boiler is proposed to install a gas turbine with sufficient conditions generate electricity for the entire site and still be able to trade the surplus energy to be sold to the utility. The result of this proposed system showed an excellent efficiency, compared to the conventional system, which technically is presented as very viable.
8

Análise do efeito da convecção forçada para resfriamento de sistema térmico fotovoltaico /

Reis, Renato Candido January 2020 (has links)
Orientador: Elaine Maria Cardoso / Resumo: O presente trabalho consistiu na análise teórica e experimental de um sistema híbrido PVT - fotovoltaico/térmico. Este consiste de um painel fotovoltaico (PV), com sistema de rastreamento, para aproveitar a radiação solar direta e difusa, e de um sistema d e resfriamento por convecção forçada acoplado, permitindo gerar eletricidade e calor em um único processo além de reduzir a temperatura de operação de um painel solar fotovoltaico comercial e, assim, melhorar sua eficiência energética. O módulo PV está instalado na região noroeste do estado de São Paulo. O conjunto experimental possui um sistema de rastreamento solar azimutal de eixo simples; a tensão e a corrente de saída do painel foram medidas para quantificar a potência produzida levando em consideração diferentes condições de operação. Todos os testes foram realizados in loco usando um painel fotovoltaico comercial, sempre levando em consideração as condições meteorológicas do dia. O rastreamento solar aumenta em 45,5% a energia gerada para um dia do mês de junho em relação a um sistema fixo. O painel fotovoltaico com a parte posterior isolada termicamente opera em condições 15 °C a 20 °C mais quente que um painel não isolado, o que implica em perdas energéticas da ordem de 7,6%. O trocador de calor tipo serpentina, com uso de água deionizada, não mostrou desempenho satisfatório ao resfriar o módulo fotovoltaico devido à significativa resistência térmica de contato com a face posterior do módulo. A análise teórica apre... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present work consisted of a theoretical and experimental analysis of a hybrid PVT – photovoltaic/thermal system. This system consisted of a photovoltaic (PV) panel with a solar tracking system to take advantage of direct and diffuse solar radiation and a forced convection cooling system. This allows the generation of electricity and useful heat in a single process in addition to reducing the operating temperature of a commercial photovoltaic solar panel and thus improves its energy efficiency. The PV module is installed in the northwest region of the state of São Paulo. The experimental apparatus had a single axis, azimuth solar tracking system; the output voltage and current of the panel were measured to quantify the power produced taking into account different operating conditions. All tests were carried out in loco using a commercial photovoltaic panel, always taking into account the weather conditions of the day. Solar tracking increases the energy generated by one day of the month by 45.5% compared to a fixed system. The temperature of the module with a thermally insulated back sheet was 15° C to 20° C hotter than a non-insulated panel, which implies energy losses of the order of 7.6%. The serpentine type heat exchanger, using deionized water, did not show satisfactory performance when cooling the photovoltaic module due to the significant thermal resistance of contact with the rear face of the module. Theoretical analysis showed errors of less than 10% compared to t... (Complete abstract click electronic access below) / Mestre
9

Respostas produtivas, comportamentais e fisiológicas de vacas criadas sob sistema biodinâmico em diferentes ambientes de pré ordenha e níveis de produção leiteira. / Production responses, behavioral and physiological of cattle raised in biodynamic system in a diferent environments pre milking.

RODRIGUES, Albério Lopes. 03 September 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-09-03T18:39:37Z No. of bitstreams: 1 ALBÉRIO LOPES RODRIGUES - TESE PPGMV 2012..pdf: 780552 bytes, checksum: 40fc6d8909d346efc5c79f859193d403 (MD5) / Made available in DSpace on 2018-09-03T18:39:37Z (GMT). No. of bitstreams: 1 ALBÉRIO LOPES RODRIGUES - TESE PPGMV 2012..pdf: 780552 bytes, checksum: 40fc6d8909d346efc5c79f859193d403 (MD5) Previous issue date: 2012 / O objetivo desse trabalho foi avaliar a influência do ambiente de pastejo sobre o comportamento e de dois ambientes de pré ordenha sobre as respostas produtivas, fisiológicas, hormonais e a qualidade do leite de vacas da raça Pardo-Suíça criadas em sistema Biodinâmico de produção. A pesquisa foi dividida em quatro capítulos. No capítulo I, por meio da literatura vigente, buscou-se informações sobre a importância da utilização do sombreamento natural e artificial na pastagem, e ainda, a eficiência da sombra e dos sistemas de resfriamento na pré ordenha de vacas leiteiras, verificando-se, serem estratégias importantes para o conforto e a produção látea desses animais. No capítulo II, foi realizada uma revisão bibliográfica sobre as características produtivas e a qualidade do leite bovino produzido ecológica e convencionalmente, observando-se que a leve inferioridade na produção e nos constituintes do leite ecológico foi devido a baixa utilização de tecnologias no manejo geral desse sistema. No capítulo III, Avaliou-se a influência do ambiente de pastejo sobre o comportamento alimentar, ruminação e ócio, noturna e diuturnamente (Ensaio I) de 32 vacas, divididas nos níveis de alta e baixa produção láctea, e o efeito dos ambientes de pré ordenha de sombra e sol (ensaio II) sobre as variáveis fisiológicas desses animais. As vacas de baixa produção alimentaram-se por mais tempo nas horas quentes do dia, quando comparados aos de alta, mas os animais de ambos os níveis produtivos pastejaram mais durante o dia que à noite (Ensaio I). Nos ambientes de pré ordenha (Ensaio II), as vacas mais produtivas foram mais sensíveis ao calor que as de baixa produção e, o ambiente de pré ordenha sombreado foi eficiente em manter as variáveis fisiológicas dentro da faixa aceitável para os bovinos leiteiros, independentemente dos níveis produtivos. No capítulo IV, avaliou-se o efeito dos ambientes de sombra e sol sobre a produção, qualidade do leite e concentração plasmática hormonal de 32 vacas, divididas nos níveis de alta e baixa produção láctea. Assim, verificouse, que o fornecimento de sombra por 1,5 horas antes da ordenha da tarde a vacas leiteiras Pardo-Suíças criadas em sistema Biodinâmico de produção, embora reduza as intempéries climáticas sobre as mesmas, não altera a sua produção e composição láctea. / The objective this work were to assess on grazing in two different environments of pre milking about the behavior in milk from cows of Brown Swiss on the productive responses, physiological, hormonal and quality from the biodynamic production system. That study was put in four chapters. Into the first chapter, we looked for information about the importance in to use the natural and artificial shading in grasslands and about the shadow efficiency and about the cooling systems on the milking in the milkmaid to confirm about the importance strategy for the comfort and the milk production. On the chapter II, we did the review in the papers about the production characterize and the milk qualify from the cattle form the ecological and traditional system to observe about the low in the production and the composition in the ecological milk was because the short technology in the handling in the used system. Into the chapter III we look for to evaluate the influence about the ambience on grazing about the food behavior rumination and resting, day and night (test I) of 32 cows, we had 16 in low and 16 in up production and look for about action of ambiences in pre milking on the sun and in with out sun. The cows from low production eating for up time in hot hours in the day when we make to comparison with the up production cows but the animal with the both level grazing more in the day (test I). In the ambiences in pre milking (Test II), the cows with the high production were more sensitive about the hot weather than the animal in the cooling weather and the ambience of pre milking with out sun were more efficiency with the physiological variations in the acceptance level for the cattle apart the two production levels. Into the chapter IV, we evaluated the effect of sun and shade environments on production, milk quality and hormonal plasma concentration of 32 cows, divided into high and low levels of milk production. In fact, it was found, that shade for 1.5 hours before the pre milking afternoon the cows in Brown Swiss from biodynamic production system, while reducing the influence weather in the cows, does not improve its yield and the composition milk.

Page generated in 0.133 seconds