• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 886
  • 19
  • 13
  • 10
  • 10
  • 10
  • 7
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 930
  • 930
  • 638
  • 442
  • 341
  • 305
  • 226
  • 213
  • 197
  • 139
  • 116
  • 113
  • 110
  • 108
  • 105
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
511

Diagnóstico de distúrbios de tensão em sistemas de distribuição de energia elétrica usando um algoritmo imuno-neural

Silva, James Clauton da [UNESP] 29 October 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-10-29Bitstream added on 2015-03-03T12:06:22Z : No. of bitstreams: 1 000808453.pdf: 1098297 bytes, checksum: 99a8ff6015e19ecb65fcf8b48a61bf82 (MD5) / Nesta pesquisa, apresenta-se uma nova abordagem para o diagnóstico de distúrbios de tensão em sistemas de distribuição de energia elétrica, usando como ferramenta um algoritmo Imuno-Neural. Trata-se, basicamente, de realizar a junção de um algoritmo imunológico de seleção negativa com uma rede neural artificial ARTMAP-Fuzzy. Partindo-se das medições realizadas em uma subestação de distribuição por um sistema de aquisição de dados SCADA, um módulo imunológico é empregado para realizar a detecção, identificando anormalidades por meio de um janelamento das curvas oscilográficas, separando, desta forma, o sinal em parcelas menores para a análise. Assim, no módulo neural, a classificação das anormalidades é realizada. A principal aplicação desta nova ferramenta é auxiliar na tomada de decisões e facilitar a operação do sistema durante a ocorrência de perturbações de tensão. Visando ilustrar a eficiência do método proposto, foram realizadas simulações de sistemas de distribuição de energia elétrica contendo 33, 84 e 134 barras, respectivamente, usando-se o aplicativo EMTP. Os resultados obtidos com esta nova abordagem evidenciam uma melhoria em termos de eficiência e de precisão, quando comparados à literatura / In this research we present a new approach to the diagnosis of voltage disturbances in power distribution systems, using as one tool Immune Neural algorithm. This proposal is basically to hold the junction of an immune negative selection algorithm with an artificial neural network ARTMAP-Fuzzy. Thus, starting from measurements made in a distribution substation for SCADA system for acquiring data, an immunological module performs the detection process, identifying abnormalities through a windowing performed by the oscillographic curves, thereby separating the signal into smaller portions for analysis module and so on neural classification of abnormality is performed. The main application of this new tool is to assist in decision making and facilitate the operation of the system for failures. To evaluate the efficiency of the proposed method simulations of electric power distribution systems were performed in three systems EMTP software distribution containing 33, 84 and 134 bar, respectively. The results obtained with this new approach demonstrate accuracy and efficiency when compared to literature
512

Estudo da estabilidade a pequenas perturbações de sistemas elétricos multimáquinas com dispositivos FACTS do tipo SSSC e controladores suplementares (POD e PSS) /

Pupin, Carlos Eduardo. January 2009 (has links)
Orientador: Percival Bueno de Araujo / Banca: Francisco Villarreal Alvarado / Banca: Élcio Precioso de Paiva / Resumo: Este trabalho apresenta estudos referentes à estabilidade a pequenas perturbações do sistema elétrico de potência, considerando a atuação de FACTS para o amortecimento das oscilações eletromecânicas de baixa freqüência. É abordado o dispositivo FACTS SSSC (Static Synchronous Series Compensator). Para este fim o sistema elétrico é modelado, modificando-se o Modelo de Sensibilidade de Potência para se inserir o compensador. Para melhorar a estabilidade do sistema desenvolvido, controladores são propostos para maximizar o desempenho do dispositivo SSSC, e dessa forma introduzir amortecimento ao sistema elétrico. Acrescenta-se ao modelo desenvolvido os Estabilizadores de Sistemas de Potência (ESP ou PSS - Power System Stabilizers) e o Power Oscillation Damping (POD), para atuação conjunta com o SSSC. Utilizando os fatores de participação e teoria de resíduos é possível encontrar a melhor localização para instalação dos dispositivos e realizar o ajuste dos parâmetros dos controladores. Simulações são realizadas para dois sistemas teste; um de quatro e outro de dez geradores. A partir dos resultados obtidos conclui-se pela potencialidade da utilização do SSSC para a melhoria da estabilidade a pequenas perturbações do sistema elétrico de potência. / Abstract: This work presents studies to provide damping to low frequencies oscillations of the electrical power systems by FACTS devices, considering SSSC (Static Synchronous Series Compensator). This is developed and implemented using the Power Sensitivity Model for multimachine systems. Afterwards, the SSSC devices are introduced as well as the controllers. The PSS (Power Systems Stabilizers) and POD (Power Oscillation Damping) controllers has been included using the participation factor and residue number theory to examine their best allocation on the electrical power systems. The study is based on modal analysis and time domain simulations using two test systems: four and ten generators. The simulation results show the capability of this method for small signal stability improvement for the electric power systems. / Mestre
513

Desenvolvimento de um micromedidor inteligente para gerenciamento pelo lado da demanda em redes elétricas inteligentes

Custódio, Elaine Silva January 2013 (has links)
Orientador : Prof Dr Alexandre Rasi Aoki / Co-orientadora : Profª. Drª. Rhelma S. P. Fernandes / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia Elétrica. Defesa: Curitiba, 29/08/2013 / Inclui referências / Área de concentração: Sistema de energia / Resumo: O gerenciamento pelo lado da demanda (DSM – Demand-Side Management) se caracteriza por um conjunto de medidas para controle da carga do usuário com o objetivo de operar o sistema elétrico de forma mais equilibrada. Este gerenciamento é discutido há mais de 20 anos, mas agora com o desenvolvimento das redes elétricas inteligentes (smart grid) que trabalha com sistemas integrados de medição, controle e supervisão inteligentes, pode ter sua atuação e implementação efetiva. Este trabalho tem como principal objetivo propor um micromedidor inteligente de energia para o gerenciamendo pelo lado da demanda, utilizando os conceitos de redes elétricas inteligentes, de forma a minimizar o custo do consumo de energia. O sistema de gerenciamento pelo lado da demanda é constituído por micromedidores de energia (smart plugs) que coletam os dados de um determinado eletrodoméstico ou circuito elétrico em uma residência, geram um histórico desses dados e através de um algoritmo implementa os métodos de gerenciamento pelo lado da demanda, como corte de carga em horários de tarifa alta e corte de stand-by. Os micromedidores inteligentes de energia desenvolvidos neste trabalho atuam como medidores de energia, computando o consumo individualizado de cada carga a ele conectado, assim como, através do protocolo ZigBee, possibilita o corte da carga via comando remoto, via agendamento ou devido a sobrecarga, agindo assim como um elemento importante na implantação prática dos métodos de gerenciamento pelo lado da demanda. Finalmente são apresentados os dados coletados e as simulações realizadas com valores de tarifas convencional e branca. Os micromedidores inteligentes de energia foram testados em uma residência unifamiliar a fim de validar a aplicação dos micromedidores desenvolvidos para implementação do gerenciamento pelo lado da demanda visando as redes elétricas inteligentes. Como resultado final verificou-se uma economia para o consumidor, a conscientização do consumidor sobre a forma de utilização da energia e a geração de um histórico de consumo que pode ser usado para diversos estudos. / Abstract: The demand side management (DSM) is characterized by a set of measures to control the user load in order to operate the electric system more evenly. This management is discussed for over 20 years, but now with the development of smart grid working with integrated systems for measurement, control and intelligent supervision, may have its operations and effective implementation. This paper aims to propose an intelligent smart plug for demand side management, using the concepts of smart grids, in order to minimize the cost of energy consumption. The management system on the demand side consists of smart plugs that collect data from a particular appliance or electrical circuit in a residence, a historic generate such data through an algorithm and implements the methods of side management demand, as load shedding schedules in high cutting rate and stand-by. Smart plugs developed in this work is the energy meters, computing the individual consumption of each load connected to it as well as by the ZigBee protocol, enables the cutting load by remote control via scheduling, or due to overload acting as an important element in the practical implementation of management methods on the demand side. Finally the collected data and the simulations with values of conventional and white rates are presented. Smart plugs were tested in a single family residence in order to validate the application of smart plugs developed for implementation of demand side management targeting smart grids. As final result there was a savings to the consumer, consumer awareness on how to use energy and generate a history of consumption that can be used for various studies.
514

Mini-inversores para aproveitamento de energia fotovoltaica, com técnicas de MPPT, sincronismo e conexão com a rede de CA em BT, proteção de ilhamento, gerenciamento da energia e da operação

Alves, Marcos Gutierrez [UNESP] 22 February 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:31Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-02-22Bitstream added on 2014-06-13T20:29:01Z : No. of bitstreams: 1 alves_mg_me_ilha.pdf: 12762635 bytes, checksum: b76892388566205b119c3e34cf5587f8 (MD5) / Considerando-se as políticas mundiais e nacionais com relação às mudanças climáticas decorrentes da ação humana, no contexto da produção e consumo de energia elétrica, novas fontes renováveis e alternativas para a produção de energia elétrica, com menores impactos ambientais e elevadas eficiências têm sido exploradas na literatura científica. Dentro deste contexto é desenvolvido neste trabalho um sistema de geração de energia elétrica de pequeno porte baseado na associação em série de poucos painéis solares fotovoltaicos. São apresentadas análises e simulações de diversas estruturas monofásicas não isoladas que contemplam o estado da arte e integram parte das estruturas mais utilizadas pela indústria. O sistema proposto para operar como Geração Distribuída (GD) é um sistema a duplo estágio, composto pelo conversor elevador Boost entrelaçado e em cascata com o inversor monofásico em ponte completa. O sistema de GD proposto possui um algoritmo tipo P&O (Perturband Observe) para a extração da máxima potência (MPPT – Maximum Power Point Tracking), mesclando o algoritmo P&O para o rastreamento do MPP, com o potencial do algoritmo Vcte (Tensão constante) para o processo de inicialização do sistema, melhorando o aproveitamento da energia advinda dos painéis fotovoltaicos. Além disso, em virtude da necessidade de conexão segura deste sistema à rede pública de distribuição de energia elétrica em corrente alternada, é implementado um método de sincronismo com a rede CA em baixa tensão; além da análise e síntese de um algoritmo híbrido para detecção e proteção de ilhamento, a fim de garantir a segurança do sistema e dos usuários. O controle do conversor, a técnica de MPPT, a detecção e proteção de ilhamento, bem como o sincronismo com a rede em CA, são implementadas... / Considering the global and national policies related to climate change due to human action, in the context of production and consumption of electricity, new renewable and alternative sources for electricity production with less environmental impacts and high efficiencies have been proposed and analyzed in the scientific literature. In this context, this work it is developed a photovoltaic small electrical generation system in order to operate with a few series connected photovoltaic panels. Moreover, it is presented analyses and simulations of several structures that include the state of the art single-phase non-isolated inverters, where the most of them are commonly used by industry. The proposed structure developed to operate as a distributed generation system is a dual-stage converter, composed by an Interleaved Boost Converter cascaded with a single-phase Full-Bridge Inverter. A maximum power point tracking technique is implemented and tested in order to increase energy utilization, mixing the potential of P&O algorithm together with Vcte algorithm. Furthermore, because of safe-operation grid connection necessities this work presents analysis and implementation of a hybrid anti-island detection technique with a synchronization method with the AC public low voltage grid. The converter control system and MPPT techniques, anti-island detection and management system together with the synchronization are implemented digitally... (Complete abstract click electronic access below)
515

Sistema inteligente híbrido intercomunicativo para detecção de perdas comerciais

Faria, Lucas Teles de [UNESP] 01 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-01Bitstream added on 2014-06-13T18:08:27Z : No. of bitstreams: 1 faria_lt_me_ilha.pdf: 1374393 bytes, checksum: 021c232f9110d70353e324741a8e1388 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / As perdas de energia elétrica por fraudes, ligações clandestinas ou erro na medição são denominadas Perdas Não-Técnicas ou Perdas Comerciais e seu combate tem sido prioridade quer por empresas concessionárias de distribuição de energia elétrica, quer por órgãos reguladores. Nesse contexto, neste trabalho, implementa-se computacionalmente um sistema inteligente híbrido intercomunicativo específico que se baseia no emprego de diferentes técnicas oriundas da área de sistemas inteligentes tais como redes neurais e lógica fuzzy em módulos independentes e que se comunicam entre si. O sistema é baseado em três pilares: extração automática de conhecimento a partir da base de dados da concessionária, incorporação na metodologia do conhecimento e experiência de especialistas e, em último, consultas na base de dados por características específicas de cada cliente. A metodologia utiliza simultaneamete inúmeros dados reais de entrada de natureza diversa e combina várias técnicas a fim de verificar o risco percentual de cada cliente de possuir alguma anomalia que implique em perda comercial. Além dos dados cadastrais e do histórico de consumo mensal dos clientes, comumente utilizados pelos trabalhos orientados à detecção de perdas comerciais, a metodologia proposta utilizou também dados adicionais tais como a lista de nomes e de atividades suspeitas. A utilização de dados adicionais possibilitou uma melhoria na detecção de clientes anômalos, grande parte dos quais seriam possivelmente considerados normais pelos trabalhos da literatura avaliada. Neste trabalho, pretende-se detectar as perdas comerciais de maneira mais rápida e precisa possível. Investigações adicionais devem ser feitas posteriormente para encontrar quais são as causas que culminaram em altas perdas comerciais em... / Electrical energy losses due to theft, fraud or error in the measurement are called Non-Technical Losses and their reduction has been a priority utilities power and by regulators. In this context, this paper presents the computational implementation of an intelligent hybrid system that combines techniques such as neural networks and fuzzy logic. The system is based on three pillars: knowledge extraction from the database utility, incorporating the methodology of knowledge and experience of experts and queries the database for specific features of each client. The methodology uses several simultaneous input of diverse nature and combines several techniques to verify the percentage risk of each customer to have some problem to configure non-technical losses as fraud, defective in the measurement system. In this paper, the main objective is to locate the focus of the problem more quickly. Further investigations should be made later to find what are the causes that resulted in high nontechnical losses in a feeder or in a specific region. This work covers the registered customers at utilities power, especially residential... (Complete abstract click electronic access below)
516

O modelo de injeção de potência do TCSC e sua aplicação no estudo da estabilidade a pequenas perturbações

Almada, Leandro Momenté [UNESP] 01 June 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-06-01Bitstream added on 2014-06-13T19:08:06Z : No. of bitstreams: 1 almada_lm_me_ilha.pdf: 552123 bytes, checksum: bb24b3e82f3436a173c7b23090715999 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O principal objetivo deste trabalho é a utilização do modelo de injeção de potência do dispositivo FACTS TCSC (Thyris-tor Controlled Series Capacitor) na análise da estabilidade a pequenas perturbações de sistemas elétricos de potência. Para atingir este objetivo é deduzido o modelo de injeção de potência do TCSC, cujo equacionamento é adicionado ao Modelo de Sensibilidade de Po-tência (MSP), utilizado para representar o sistema elétrico de potência (SEP). Para o amortecimento das oscilações eletromecânicas de baixa frequência do SEP são utilizados dois modelos para os controladores, um que considera somente um ganho proporcional e outro comumente chamado na literatura de controlador suplementar de amortecimento (POD – Power Oscillation Damping) que contém também blocos de avanço- atraso de fase. Ambos os controladores devem atuar em conjunto com o TCSC para fornecer amortecimento ao SEP. Neste trabalho o sinal de entrada para os dois controladores é a variação da potência ativa na linha de transmissão de instalação do TCSC e seus parâmetros são ajustados de duas formas: pelo método dos resíduos e utilizando o toolbox rltool (SISO) do software MATLAB. Para a validação do equacionamento desenvolvido foram realizadas simulações em um sistema de potência simétrico, de duas áreas, composto de 4 geradores e 10 barras / This work presents a power injection model for the Thyristor Controlled Series Compensator (TCSC), a Flexible AC Transmission Systems (FACTS) device, for small signal stability analysis in the electric power systems. To achieve such goal, the TCSC injection power model equations are summed up to the Power Sensitivity Model (PSM) which is used to represent the electric power system (EPS). For the low frequency electromechanical oscillation damping, two models are used to represent the controller: 1. A proportional control and; 2. A supplementary control known as Power Oscillation Damping (POD), which also comprehends lead-lag blocks. Both controllers, previously cited, must work together with the TCSC to damp oscillations in the EPS. In this work, the input signal for both controllers is the real power flow variation in the transmission line where the TCSC is placed and the controllers parameters are adjusted using the residues method and the Matlab toolbox rltool (SISO). Several simulations in a symmetrical, two areas power system, composed of four generators and ten busses, are provided in way to validate the power injection model and are discussed in this work
517

Características de sistemas de transmissão tetrafásicos submetidos a transitórios lentos e rápidos

Brandt, Ivan Scherole [UNESP] 29 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-29Bitstream added on 2014-06-13T20:49:12Z : No. of bitstreams: 1 brandt_is_me_ilha.pdf: 996540 bytes, checksum: 97a4b2aa127103d8e81ea086dc41e70e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Entre tantas tecnologias alternativas desenvolvidas ao longo das últimas décadas, procurando aumentar a eficácia das técnicas convencionais ou propondo novas técnicas não convencionais na transmissão da energia elétrica a longas distâncias e lugares de difícil acesso, o estudo proposto apresenta alguns conceitos e características para sistemas de transmissão constituídos por quatro fases genéricas. O sistema de transmissão tetrafásico tem sido tema de diversos estudos e aplicações em alguns países da Europa e Ásia, apresentando algumas vantagens quando comparado ao sistema de transmissão trifásico convencional. Esse sistema pode ser facilmente integrado ao sistema trifásico por meio de transformadores, amplamente abordado por diversas referências bibliográficas. Nesse estudo foi realizado uma análise comparativa das possíveis sobretensões ocorridas nos domínios da frequência e do tempo entre os sistemas de transmissão trifásico e tetrafásico, avaliando as características elétricas e as respostas transitórias eletromagnética e impulsiva, mostrando novas vantagens sobre esta tecnologia, fornecendo uma avaliação completa sobre o tema / Among the many alternative technologies developed over the past decades, seeking to increase the effectiveness of conventional techniques or proposing new non-conventional techniques in the transmission of electricity over long distances and places of difficult access, the proposed study presents some concepts and features to transmission systems that are constituted of four generic phases. The four-phase transmission system has been subject of numerous studies and applications in some countries in Europe and Asia, presenting some advantages compared to the conventional three-phase transmission system. This system can be easily integrated into the three-phase system through transformers, thoroughly approached by several bibliographical references. In this study was made a comparative analysis of the possible overvoltages that occurred in the areas of frequency and time between the transmission systems of three-phase and four-phase, evaluating the electrical characteristics and the transient answers, electromagnetic and impulsive, showing new advantages over this technology, providing a complete evaluation of this issue
518

Estudo da estabilidade a pequenas perturbações de sistemas elétricos multimáquinas com dispositivos FACTS do tipo SSSC e controladores suplementares (POD e PSS)

Pupin, Carlos Eduardo [UNESP] 28 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-28Bitstream added on 2014-06-13T20:08:35Z : No. of bitstreams: 1 pupin_ce_me_ilha.pdf: 1801957 bytes, checksum: 06dbcbacdd038bf23cf8b0bfc982dbeb (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta estudos referentes à estabilidade a pequenas perturbações do sistema elétrico de potência, considerando a atuação de FACTS para o amortecimento das oscilações eletromecânicas de baixa freqüência. É abordado o dispositivo FACTS SSSC (Static Synchronous Series Compensator). Para este fim o sistema elétrico é modelado, modificando-se o Modelo de Sensibilidade de Potência para se inserir o compensador. Para melhorar a estabilidade do sistema desenvolvido, controladores são propostos para maximizar o desempenho do dispositivo SSSC, e dessa forma introduzir amortecimento ao sistema elétrico. Acrescenta-se ao modelo desenvolvido os Estabilizadores de Sistemas de Potência (ESP ou PSS – Power System Stabilizers) e o Power Oscillation Damping (POD), para atuação conjunta com o SSSC. Utilizando os fatores de participação e teoria de resíduos é possível encontrar a melhor localização para instalação dos dispositivos e realizar o ajuste dos parâmetros dos controladores. Simulações são realizadas para dois sistemas teste; um de quatro e outro de dez geradores. A partir dos resultados obtidos conclui-se pela potencialidade da utilização do SSSC para a melhoria da estabilidade a pequenas perturbações do sistema elétrico de potência. / This work presents studies to provide damping to low frequencies oscillations of the electrical power systems by FACTS devices, considering SSSC (Static Synchronous Series Compensator). This is developed and implemented using the Power Sensitivity Model for multimachine systems. Afterwards, the SSSC devices are introduced as well as the controllers. The PSS (Power Systems Stabilizers) and POD (Power Oscillation Damping) controllers has been included using the participation factor and residue number theory to examine their best allocation on the electrical power systems. The study is based on modal analysis and time domain simulations using two test systems: four and ten generators. The simulation results show the capability of this method for small signal stability improvement for the electric power systems.
519

Estudo de bifurcações e aplicações em análise de sistemas de energia elétrica

Batista, Marcelo Fuly [UNESP] 28 August 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-08-28Bitstream added on 2014-06-13T19:28:04Z : No. of bitstreams: 1 batista_mf_me_ilha.pdf: 3972180 bytes, checksum: 619117071d2971bec37b4fbde27e7368 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta um estudo sobre a relação entre os principais tipos de bifurcações que ocorrem em sistemas elétricos de potência e em quais ocasiões elas podem ocorrer em máquinas síncronas com ou sem RAT (Regulador Automático de Tensão). Para explorar tais fenômenos, primeiramente o sistema é modelado, sendo utilizado para o caso MBI (Máquina - Barramento In nito) o modelo um eixo e, então, a matriz de estado é calculada para a análise dos autovalores. Para os sistemas multimáquinas estudados, são incluídos dois enrolamentos amortecedores nos eixos d ¡ q. São então apresentados os métodos de análise de estabilidade transitória convencionais, amplamente utilizados, conhecidos como método Tradicional e Método Direto. As condições para a ocorrência de bifurcações são analisadas utilizando os coe - cientes linearizados do modelo de He ron-Phillips para o caso MBI, onde é mostrado que se espera perder a estabilidade para o sistema com regulador automático de tensão através de uma bifurcação de Hopf e para o caso sem RAT através de uma bifurcação Sela-Nó. Por m, é analisado o ciclo-limite para o caso de uma máquina - barramento in nito e para sistemas multimáquinas através do modelo não-linear. A região de estabilidade é analisada no plano de fase, sendo mostrada a necessidade de incluir a variação de uxo no enrolamento de campo para uma análise correta da estabilidade. É também mostrado que este ciclo-limite pode reduzir a fronteira de estabilidade calculada pelo método convencional. / The aim of this study is the relation among main types of bifurcations that occur in electrical power systems and the circumstances they can happen with the synchronous machines considered with or without AVR (Automatic Voltage Regulator). To explore such phenomena, the system is rst modeled with the synchronous machines described by the one axis model for the MIB (Machine - In nite Bus) case , and so the state matrix is computed for the analysis of its eigenvalues. For multimachine systems case two windings dampers are included in d-q axes. The conditions for the occurrence of bifurcations are analyzed using the coe cients of the He ron-Phillips model for MIB case, where it is shown that one expects the system with automatic voltage regulator lose synchronism through a Hopf bifurcation and for the case without RAT through a Saddle- Node Bifurcation. Finally, the nonlinear model is accounted for in order to consider the limit-cycle for the case of one machine - in nite bus case as well as for multimachine system. Since internal voltage a ects the boundary of the stability region it must be considered. Then the phase portrait does not su ce and the trajectories must to be observed in a sub space de ned with the internal voltage. It is also shown that this limit-cycle can reduce the boundary of stability calculated by means of the direct method.
520

Um estudo dos efeitos da atuação de um SVC sobre as interações entre máquinas de um sistema de potência multimáquinas

Marques, Meire de Melo [UNESP] 05 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-05Bitstream added on 2014-06-13T18:48:10Z : No. of bitstreams: 1 marques_mm_me_ilha.pdf: 416904 bytes, checksum: b9ba21a46bd3f29605dcb6d41856e1dc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do presente trabalho é analisar a influência da atuação do SVC no desempenho dinâmico e transitório de um sistema de energia elétrica multimáquinas, focando as interações máquina-versus-máquina, por meio das admitâncias de transferência entre as barras internas dos geradores Cada admitância de transferência entre máquinas do sistema depende diretamente das variações da susceptância do SVC, e, para expressar esta dependência foi definido um coeficiente denominado Fator de Efeito. Mostra-se que este fator avalia com propriedade o efeito exercido pela ação do SVC sobre cada admitância de transferência entre máquinas do sistema, e dele se pode inferir quais pares de máquinas são mais e quais são menos afetados. Mostra-se ainda que, embora o Fator de Efeito possa apresentar variação de valores em diferentes condições de carregamentos, o mesmo não perde sua capacidade de discriminação de importância da compensação para interações entre máquinas. Notadamente, a discriminação da importância para interações intra e inter-áreas foi preservada em todas as situações de carregamentos consideradas. Considera-se que o Fator de Efeito poderá ser de grande utilidade em procedimentos de análise do desempenho de um SEE sob atuação de um SVC, bem como em procedimentos de projeto e ajuste de controles do dispositivo. / The aim of this study is to analyze the influence of the action of a SVC in the dynamic and transient performance of a multimachine power system, with the focus putted on the machine versus machine interactions, by means of the their transfer admittance. The internal generators nodes transfer admittances are affected by the performance of the SVC and a coefficient named Effect Factor is defined in order to take it into account. It is shown that this factor provides an appropriate evaluation of relative importance of the SVC effects among all of the pairs of machines transfer admittances. It is also shown that the Effect Factor does not lose its discrimination ability when considering different system loading conditions. Especially the intra- and inter-area discrimination has been preserved in all of the various considered cases. It is expected that the effect factor can be very useful in power system performance analysis under SVC action, as well as in design and tuning methods for the device control.

Page generated in 0.0792 seconds