• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 886
  • 19
  • 13
  • 10
  • 10
  • 10
  • 7
  • 3
  • 2
  • 2
  • 1
  • Tagged with
  • 930
  • 930
  • 638
  • 442
  • 341
  • 305
  • 226
  • 213
  • 197
  • 139
  • 116
  • 113
  • 110
  • 108
  • 105
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
821

Análise da proteção antiilhamento de geradores de indução conectados em redes de distribuição de energia elétrica / Analysis of the anti-islanding protection of induction generators connected to electric power distribution systems

Meira, Paulo César Magalhães, 1985- 15 August 2018 (has links)
Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T23:24:26Z (GMT). No. of bitstreams: 1 Meira_PauloCesarMagalhaes_M.pdf: 4399317 bytes, checksum: abd35262b6780f553e52831e63c6947c (MD5) Previous issue date: 2010 / Resumo: Em redes de distribuição, ilhamento ocorre quando parte da rede elétrica é desconectada do restante do sistema da concessionária, mas continua a ser energizada por um ou mais geradores distribuídos conectados a ela. Esta ocorrência deve ser evitada porque coloca em risco a segurança de pessoas e equipamentos. Diversos trabalhos têm sido desenvolvidos na análise do comportamento ilhado e da proteção antiilhamento de geradores síncronos e de geradores não-rotativos conectados via conversores eletrônicos. No entanto, pouca atenção tem sido dada aos casos envolvendo geradores de indução, sejam eles geradores duplamente alimentados ou com rotor tipo gaiola de esquilo. Portanto, o objetivo desta dissertação de mestrado é investigar o comportamento destes geradores durante ilhamentos, bem como analisar a eficiência dos relés baseados em medidas de freqüência e tensão para a realização de proteção antiilhamento. A ferramenta empregada para análise da proteção antiilhamento é a zona de não-detecção, a qual é definida como a região no espaço de desbalanço de potência reativa versus desbalanço de potência ativa em que o sistema de proteção antiilhamento não consegue detectar a situação de ilhamento dentro do tempo especificado. Tais zonas foram obtidas através de numerosas simulações de transitórios eletromagnéticos utilizando o programa PSCAD/EMTDC / Abstract: In distribution systems, islanding occurs when part of the electric system is disconnected from the remaining utility system, but continues to be fed by one or more distributed generators operating in the island. This occurrence should be avoided as it represents a safety risk to equipment and customers. There have been several research papers which analyze the islanding behavior and the anti-islanding protection of synchronous generators and non-rotating generators connected to the grid using electronic converters. Nonetheless, little attention has been spent to analyze the situations involving induction generators, either doubly-fed generators or squirrel-cage generators. Therefore, the objective of this dissertation is to investigate the behavior of these generators during islanded operation, as well as analyze the efficiency of anti-islanding protection schemes based on frequency and voltage relays. The analysis is conducted by using the non-detection zone, which is defined in the active versus reactive power imbalance space where the anti-islanding protection fails. These zones were determined by numerous electromagnetic transient simulations by using the software PSCAD/EMTDC / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
822

Estudo de técnicas de controle de fluxo de potência e de gerenciamento de ilhamento em sistemas de geração distribuída com interfaces eletrônicas de potência para conexão com a rede elétrica / Power flow control and islanding management in small power distributed generation systems using power electronics interface for the connection with the grid

Moreno Martinez, Rodolfo Manuel 15 August 2018 (has links)
Orientadores: José Antenor Pomilio, Luiz Carlos Pereira da Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T23:21:44Z (GMT). No. of bitstreams: 1 MorenoMartinez_RodolfoManuel_D.pdf: 3227759 bytes, checksum: b66cea18c73d62eee160d3b5cf012d1f (MD5) Previous issue date: 2010 / Resumo: O presente trabalho estuda problemas do controle de fluxo de potência e de gestão de ilhamento em sistemas de geração distribuída de pequeno porte nos quais a interface com a rede elétrica sejam feitas por meio de conversores eletrônicos de potência. O sistema completo apresenta conversor "on-line", no qual a potência produzida localmente é totalmente processada pelo conversor, juntamente com uma estrutura "interativa com a rede", na qual o conversor opera para manter determinados padrões de desempenho sem, no entanto, processar potência ativa. É também focalizado o problema de qualidade da energia elétrica, analisando-se maneiras de operar os conversores de modo a mitigar problemas relacionados a harmônicos. Além de estudos de modelagem e simulação, avança-se na implementação experimental de algumas das técnicas analisadas / Abstract: This work studies problems of power flow control and islanding management in small power distributed generation systems in which the interface with the grid is made through electronic power converters. The complete system has "on-line" behavior, in which the power produced locally is fully processed by the converter, and also a structure "line-interactive," in which the converter operates to maintain certain performance standards without, however, process active power. It is also focused on the problem of power quality, analyzing ways to operate the converter in order to mitigate problems related to harmonics. In addition to modeling and simulation, some experimental implementation of the proposed techniques are realized / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
823

Redes neurais artificiais aplicadas a sistemas de potencia / Artificial neural networks for load flow and external equivalents studies

Muller, Heloisa Helena, 1965- 03 December 2008 (has links)
Orientadores: Carlos Alberto de Castro Jr., Marcos Julio Rider Flores / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T05:47:59Z (GMT). No. of bitstreams: 1 Muller_HeloisaHelena_M.pdf: 1272493 bytes, checksum: d78e9e8d9a329ccbf0cc8be6f666af25 (MD5) Previous issue date: 2008 / Resumo: A operação de um sistema de energia elétrica pode ser gerenciada remotamente através dos centros de controle utilizando sistemas de gerenciamento de energia (Energy Management Systems-EMS). Nesses centros de controle são realizadas e executadas freqüentemente muitas funções em tempo real e em modo de estudo. Dentre estas funções têm-se: o controle automático da geração, a estimação de estado, análise de topologia e análise estática de segurança entre tantas outras. A base da resolução destas funções é a execução e testes de um grande número de cálculos de fluxos de potência. A estimativa de estado de um sistema de potência pode ser determinada resolvendo as equações de um fluxo de carga, que matematicamente são representadas por um conjunto de equações algébricas não lineares. Este problema é conhecido como fluxo de potência ou fluxo de carga, e o seu objetivo principal é o cálculo das magnitudes das tensões e seus ângulos de fase, e consequentemente dos fluxos de potência nas linhas de transmissão. O objetivo deste estudo é usar redes neurais artificiais (RNA) na: (a) solução do fluxo de carga (FC); (b) solução do FC considerando controle de limites de tensão nas barras PV; (c) inicialização de um FC para sistema mal condicionados; e (d) cálculo de equivalentes externos estáticos para sistemas de energia elétrica. A idéia é que um fluxo de potência baseado em RNA seja mais rápido que o fluxo de potência convencional baseado no método de Newton-Raphson, particularmente nos casos envolvendo aplicações em tempo rela e em modo de estudo avançadas de fluxos de potência no EMS / Abstract: The operation of electric power systems can be managed remote and automatically from control centers using energy management systems (EMS). In these control centers many on-line and off-line functions are carried out periodically. Among those functions, we can list: the automatic generation control, state estimation, topological analysis, and static security analysis. These functions are based on the calculation of a large number of power flows. The operating state of power systems may be determined by solving power flow equations that are mathematically represented by a set of non-linear algebraic equations. This problem is known as the load flow or power flow problem and its main objective is the calculation of all bus voltage magnitudes and angles, and consequently the power flows through the transmission lines. The goal of this study is to propose an artificial neural networks (ANN) based methodology for (a) solving the basic load flow, (b) solving basic load flow considering reactive power limits of generation (PV) buses, (c) determining a good quality load flow starting point for ill-conditioned systems, and (d) computing static external equivalent circuits. The proposed ANN based power flow solver is intended to be faster than the conventional power flow problem solvers which use Newton-Raphson method, particularly in those cases involving advanced on-line applications of the power flow problem in the EMS / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
824

Metodologias para analise do risco de ocorrencia de ilhamentos não intencionais de geradores sincronos distribuidos / Methodologies for evaluating the risk of occurrence of non intentional islanding of distributed synchronous generators

Salles Corrêa, Diogo 25 June 2008 (has links)
Orientadores: Walmir de Freitas Filho, Jose Carlos de Melo Vieira Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T06:20:40Z (GMT). No. of bitstreams: 1 SallesCorrea_Diogo_M.pdf: 1373306 bytes, checksum: a6a2357bf0c337089786c03c519bbd7d (MD5) Previous issue date: 2008 / Resumo: Geradores síncronos conectados em redes de distribuição de energia elétrica estão sujeitos a operarem de forma ilhada após contingências como, por exemplo, curtos-circuitos. Ilhamento ocorre quando uma parte da rede de distribuição opera eletricamente isolada da subestação da concessionária, mas continua a ser energizada por geradores distribuídos. Devido a um conjunto de implicações técnicas e de segurança, a prática atualmente utilizada pelas concessionárias e recomendada pelos principais guias técnicos é desconectar todos os geradores da rede isolada tão logo ocorra um ilhamento. Existem diversas técnicas de proteção desenvolvidas para detectar ilhamentos e a maioria delas possui limitações técnicas e são propensas a falharem em determinadas situações. Neste contexto, torna-se importante conhecer a probabilidade ou risco da proteção falhar na detecção de ilhamentos em sistemas de distribuição de energia elétrica com geradores distribuídos e, por conseguinte, decidir se o sistema de proteção utilizado é adequado ou não. A falha da detecção de uma situação de ilhamento é tecnicamente denominada ilhamento não intencional. Esta dissertação de mestrado apresenta uma série de metodologias desenvolvidas para analisar o risco da ocorrência de ilhamentos não intencionais devido à falha do sistema de proteção de geradores síncronos. O sistema de proteção antiilhamento considerado neste trabalho é composto por relés baseados em medidas de freqüência e/ou tensão visto que atualmente estes são considerados os dispositivos mais eficientes para realizar tal tarefa. Como os desempenhos desses relés estão fortemente relacionados aos desbalanços de potência ativa e reativa na rede ilhada, respectivamente, as metodologias desenvolvidas baseiam-se nas curvas de carga do sistema de distribuição, nos patamares de geração de potência ativa e reativa e no cálculo de um índice numérico que indica o risco de falha da proteção antiilhamento. Diversos métodos eficientes foram desenvolvidos para calcular diretamente este índice de risco sem a necessidade de executar numerosas simulações de transitórios eletromagnéticos. Ressalta-se que os principais fatores que afetam o desempenho do sistema de proteção antiilhamento podem ser prontamente determinados com a aplicação das metodologias desenvolvidas. Os resultados obtidos mostraram-se precisos quando comparados aos obtidos por meio de repetidas simulações do tipo de transitórios eletromagnéticos / Abstract: Distributed synchronous generators connected to distribution power systems are prone to operate islanded after contingencies such as short circuits. Islanding occurs when a portion of the distribution network operates electrically isolated from the utility grid substation, yet continues to be energized by local distributed generators connected to the isolated system. Due to a number of technical and safety concerns, the procedure currently adopted by utilities and recommended by the main technical guides is to disconnect all the generators immediately after an islanding event. There are several anti-islanding techniques and the majority of them present technical limitations so that they are likely to fail in certain situations. In this context, it becomes important to know the probability or the risk of the protection scheme to fail in the detection of islanding events in distribution power systems containing distributed generators and, ultimately, determine whether the protection scheme under study is adequate or not. The failure of islanding detection is technically denominated non intentional islanding. This work presents a number of methodologies developed to evaluate the risk of occurrence of non intentional islanding due to the failure of synchronous generators protection systems. The anti-islanding protection system considered in this work is composed of relays based on measures of frequency and/or voltage, since these are considered to be the most efficient methods to perform this task. As the performance of these relays is strongly dependent on the active and reactive power imbalances in the islanded system, respectively, the methodologies are based on the distribution network feeder load curves, the active and reactive power generation levels and on the calculation of numerical index to quantify the risk level of protection system failure. Efficient methods were developed to directly calculate these risk indexes without performing several electromagnetic transient simulations. Through these methods, the main factors impacting on the performance of the antiislanding protection schemes can be determined. The results obtained by the usage of the proposed methodologies presented a very good match with those obtained by electromagnetic transient simulations / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
825

Maximização da margem de estabilidade sujeito a minimização do custo de produção da energia eletrica utilizando formulação em dois niveis / Maximization of the stability margin subjected to electric power generation cos minimization using a bilevel programming approach.

Aria Arias, David 29 August 2008 (has links)
Orientadores: Carlos Alberto de Castro Junior, Alexandre de Assis Mota / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-11T20:26:47Z (GMT). No. of bitstreams: 1 AriaArias_David_M.pdf: 982619 bytes, checksum: 902edfe03a42ce4e64a22f698a4267cf (MD5) Previous issue date: 2008 / Resumo: O presente trabalho apresenta um modelo para o planejamento da operação de sistemas de potência visando maximizar a margem de estabilidade de tensão ao mesmo tempo em que minimizam-se os custos da produção da energia (despacho econômico). O objetivo é obter uma solução para o planejamento da operação da rede que leve em conta não só aspectos técnicos, mas também econômicos. Para que esse objetivo possa ser atingido, esse problema é formulado como um problema da programação bilevel (BLPP) ou em dois níveis. O modelo bilevel permite definir funções objetivo distintas para maximizar a margem da estabilidade de tensão e, ao mesmo tempo, conseguir um despacho econômico ótimo, permitindo a imposição de diferentes restrições para as variáveis internas e externas do problema. Uma vez que o BLPP apresenta-se como um problema matemático complexo, ele é reduzido a um problema de otimização de um só nível (single-level), substituindo-se o problema de otimização interno pelas condições de ótimalidade de Karush-Kuhn-Tucker (KKT). Foram realizados testes e simulações em diferentes sistemas elétricos, sendo que os resultados obtidos atestam a validade da metodologia proposta. Além disso, a formulação e o método de solução do BLPP apresentados neste trabalho são mais simples que outros encontrados na literatura, tornando essa metodologia bastante flexível para a utilização e investigação de outras funções objetivo, variáveis e parâmetros de controle. / Abstract: This work presents a model for power systems operation planning that aims to maximize the voltage stability margin and also the economic dispatch. The objective is to obtain a solution for the network operation planning that takes into account both technical and economical aspects. In order to reach this goal, this problem is formulated as a bilevel programming problem (BLPP). The bilevel model allows to define distinct objective functions for maximizing the voltage stability margin looking, simultaneously, for an optimum economic dispatch, and permitting the imposition of different constraints to the variables of the inner and outer problems. Since the BLPP is a complex mathematical problem, it is reduced to a single-level optimization problem by replacing the inner optimization problem by its Karush-Kuhn-Tucker optimality conditions. Simulations and tests were carried out for different electric networks, and the results show that the proposed methodology is valid. Moreover, the BLPP formulation and its solution method are simpler than other formulations found in the literature, making the methodology very flexible to accommodate other objective functions, variables and control parameters. / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
826

Desenvolvimento de uma metodologia para a coordenação hidrotérmica de longo prazo em mercado elétrico competitivo / DEVELOPMENT OF A METHODOLOGY FOR THE COORDINATION HYDROTHERMAL-TERM IN ELECTRIC MARKET COMPETITIVE

Paredes, Romel Wiliams Jimenez 26 February 2007 (has links)
Made available in DSpace on 2016-08-17T14:53:12Z (GMT). No. of bitstreams: 1 Romel Jimenez.pdf: 804071 bytes, checksum: 8f161d1f48519af0d6ee9068f4876a93 (MD5) Previous issue date: 2007-02-26 / In this work a methodology based on linear programming for long-term hydrothermal scheduling of electric power systems is proposed. The objective of the hydrothermal scheduling is to find an optimal operation for a specific time interval and with high reliability and minimum cost. That is equivalent to determine an optimal generation scheduling for the power plants and for each time interval considered, in order to the power system satisfies the forecasted demand. Linear models of the power system components are adopted, and with the option to solve systems with multiple reservoirs and buses. It was implemented a computer program using MATLAB platform for application to small test power systems and configurations of real-size systems such as the interconnected Peruvian System and the Brazilian South-Souheast System. For the solution of the linear optimization problem was used the interior points method. From the analysis of the test systems results is concluded that the linear model may capture adequately the relevant characteristics of the real power system and it may be eficient and precise such as the detailed model. / Neste trabalho é proposta uma metodologia baseada em programação linear para a solução da coordenação hidrotérmica de longo prazo de sistemas de energia elétrica. O objetivo da coordenação hidrotérmica é encontrar uma política de operação ótima em um determinado período de tempo, com alta confiabilidade e custo mínimo. Isto equivale a determinar um cronograma ótimo de geração para cada usina, a cada intervalo de tempo, de modo que o sistema atenda a demanda prevista. Adotam-se modelos lineares dos componentes do sistema de potência, com a opção de resolver sistemas com múltiplos reservatórios e múltiplas barras. Foi implementado um programa computacional em MATLAB para a solução de sistemas teste de pequeno porte e configurações de sistemas de potência reais tal como o Sistema Interligado Peruano e o Sistema Brasileiro da Bacia Sul-Sudeste. Para a solução do problema de otimização linear foi utilizado o método de pontos interiores. Da análise dos resultados com os sistemas teste conclui-se que o modelo linear pode capturar adequadamente as características relevantes do sistema real e pode ser tão eficiente e preciso quanto o modelo detalhado.
827

MÉTODOS ALTERNATIVOS PARA ESTIMAÇÃO DE ESTADO EM SISTEMAS DE ENERGIA ELÉTRICA / ALTERNATIVE METHODS FOR ESTIMATION OF STATE IN POWER SYSTEMS

Frazão, Rodrigo José Albuquerque 23 January 2012 (has links)
Made available in DSpace on 2016-08-17T14:53:18Z (GMT). No. of bitstreams: 1 Dissertacao Rodrigo Albuquerque.pdf: 3312916 bytes, checksum: c9ee0be229b62b8aafd7816c3400351d (MD5) Previous issue date: 2012-01-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The state estimation process applied to electric power systems aims to provide a trustworthy ―image‖, coherent and complete of the system operation, allowing an efficient monitoring. The state estimation is one of the most important functions of energy management systems. In this work, will be proposed alternative methods of state estimation for electric power systems in the levels of transmission, subtransmission and distribution. For transmission systems are proposed two hybrid methods considering the insertion of conventional measurements combined with phasor measurements based on phasor measurement unit (PMU). To estimate the state in subtransmission systems is proposed an alternative method which, in occurrence of failures in active and/or reactive meters in the substations, uses a load forecasting model based on criteria similar days and application of artificial neural networks. This process of load forecasting is used as a generator of pseudo measurements in state estimation problem, which takes place through the propagation of phasor measurements provided by a PMU placed in the boundary busbar. For the distribution system state estimation the proposed method uses the mathematical method of weighted least squares with equality constraints by modifying the set of measurements and the state variables. It is also proposed a methodology evaluation of the PMUs measurement channel availability for observability analysis. The application of the proposed methods to test systems shows that the results are satisfactory. / O processo de estimação de estado aplicado a sistemas elétricos de energia tem como objetivo fornecer uma imagem confiável, coerente e completa da operação do sistema, permitindo um monitoramento eficiente. A estimação de estado é uma das funções mais importantes dos sistemas de gerenciamento de energia. Neste trabalho são propostos métodos alternativos de estimação de estado para sistemas elétricos nos níveis de transmissão, subtransmissão e de distribuição. Para sistemas de transmissão são propostos dois métodos híbridos considerando a inserção das medições convencionais combinadas com medições fasoriais baseadas na unidade de medição fasorial (PMU - Phasor Measurement Unit). Para a estimação de estado em sistemas de subtransmissão é proposto um método alternativo que, na ocorrência de falhas nos medidores de potência ativa e/ou reativa das subestações, utiliza um modelo de previsão de carga baseado no critério de dias similares e na aplicação de redes neurais artificiais. Esse processo de previsão de carga é utilizado como gerador de pseudomedições na estimação de estado, que se dá através da propagação da medição fasorial fornecida por uma PMU alocada no barramento de fronteira. Para sistemas de distribuição o método de estimação de estado proposto consiste em aplicar o método de mínimos quadrados ponderados com restrições de igualdade, modificando-se o plano de medição e as variáveis de estado. Também é proposta uma metodologia para avaliação da disponibilidade dos canais de medições da PMU e o seu impacto na observabilidade do sistema. A aplicação dos métodos propostos a sistemas teste mostram que os resultados obtidos são satisfatórios.
828

Princípio do equivalente certo no planejamento da operação de sistemas hidrotérmicos / Certainty equivalence principle in long term hydrothermal scheduling

Silva, Thayze D'Martin Costa da, 1988- 25 August 2018 (has links)
Orientadores: Secundino Soares Filho, Mônica de Souza Zambelli / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-25T07:16:16Z (GMT). No. of bitstreams: 1 Silva_ThayzeD'MartinCostada_M.pdf: 9346773 bytes, checksum: 73c504aef1611f22af50cead8deff7bf (MD5) Previous issue date: 2014 / Resumo: O Princípio do Equivalente Certo (PEC) garante que as abordagens determinística e estocástica são equivalentes na otimização de sistemas dinâmicos estocásticos quando satisfeitas certas condições. É possível que o problema de planejamento da operação energética (POE) se aproxime de satisfazer as condições do PEC, apesar de não atendê-las teoricamente. Assim, o objetivo desta dissertação é analisar a validade do PEC no âmbito da Programação Dinâmica aplicado ao POE de sistemas hidrotérmicos constituídos de um único reservatório e avaliar o impacto da violação de cada condição. As hipóteses do PEC foram analisadas progressivamente por meio da comparação dos resultados dos modelos considerados, desde o ideal que atende teoricamente às condições, até o mais próximo da realidade. Foram observadas diferenças pouco significativas entre as políticas de operação determinística e estocástica, indicando que o modelo de POE se aproxima de atender às condições do PEC. Uma consequência imediata deste estudo seria que a abordagem determinística do problema de POE para sistemas hidrotérmicos com um único reservatório pode ser tão eficaz quanto as abordagens estocásticas / Abstract: Certainty Equivalence Principle (CEP) ensures that deterministic and stochastic approaches are equivalent in stochastic dynamic systems optimization when some assumptions hold. It is possible that Long Term Hydrothermal Scheduling (LTHS) problem is close to attaining CEP¿s assumptions, although it does not attain them theoretically. Thus, the objective of this dissertation is to analyze the validity of CEP in Dynamic Programming framework applied to single reservoir LTHS problem and to evaluate the impacts of each CEP¿s condition violation. The CEP¿s conditions were progressive analyzed by comparison of the considered models results from an ideal case where theoretically assumptions hold until a case study closer to reality. Slight differences were observed between deterministic and stochastic operation policies, indicating that LTHS model is close to attain the CEP¿s conditions. An immediate consequence of this study would be that deterministic approach for the single reservoir LTHS problem can be as effective as stochastic ones / Mestrado / Energia Eletrica / Mestra em Engenharia Elétrica
829

Método da barreira modificada via reescalonamento não linear aplicado ao fluxo de potência reativa ótimo / Modified barrier method by nonlinear rescaling applied to optimal reactive power flow

Silva, Iara da Cunha Ribeiro da, 1983- 08 May 2013 (has links)
Orientador: Anésio dos Santos Júnior / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-23T02:47:49Z (GMT). No. of bitstreams: 1 Silva_IaradaCunhaRibeiroda_D.pdf: 1773553 bytes, checksum: 06519e6714ec628c0365a39c3384366d (MD5) Previous issue date: 2013 / Resumo: Nesta tese é apresentado o método da barreira modificada via princípio de reescalonamento não linear aplicado ao fluxo de potência reativa ótimo. Esse método é baseado na transformação das restrições de desigualdade do fluxo de potência reativa ótimo, gerando um problema de barreira modificado. Resolvendo uma sequência desses problemas barreira modificado, o método pode alcançar a solução do fluxo de potência reativa ótimo. A estratégia de busca é composta por dois ciclos: o primeiro minimiza a função Lagrangeana associada ao problema de barreira modificada através do método de Newton e o segundo ciclo atualiza as variáveis duais do problema não linear. O método barreira modificado é aplicado em sistemas elétricos do IEEE e os resultados são apresentados na tese / Abstract: In this thesis is presented the modified barrier method, based on the nonlinear rescaling principle and applied to the problem for optimal reactive power flow. This method is based on the transformation of nonlinear inequality constraints of the optimal power flow that generates a modified barrier problem. On searching the solution of a sequence of these problems the method can achieve the solution of the optimal power flow. The search strategy is composed by two stages: the first one update the dual variable approximation of inequality constraints of the problem. The second one minimizes the Lagrangian function of the modified barrier problem by Newton's method. This strategy has been applied to optimal power flow IEEE systems and the results are also shown in this thesis / Doutorado / Energia Eletrica / Doutora em Engenharia Elétrica
830

Análise de novos sinais para a detecção de ilhamento de geradores síncronos distribuídos / New signals for anti-islanding protection of synchronous distributed generators

Delvecchi, Esloany Daisy Carniatto 07 August 2011 (has links)
Orientadores: Walmir de Freitas Filho, José Carlos de Melo Vieira Júnior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-19T11:09:25Z (GMT). No. of bitstreams: 1 Delvecchi_EsloanyDaisyCarniatto_M.pdf: 1048681 bytes, checksum: 837e57f3ee3363dd7bb9f49a72408fe1 (MD5) Previous issue date: 2011 / Resumo: Geradores síncronos conectados em redes de distribuição de energia elétrica estão sujeitos a operarem de forma ilhada após a ocorrência de distúrbios na rede elétrica. Ilhamento ocorre quando uma parte da rede de distribuição torna-se eletricamente isolada da fonte de energia principal (subestação), mas continua a ser energizada por geradores distribuídos conectados no subsistema isolado. A prática atualmente utilizada pelas concessionárias e recomendada nos principais guias técnicos é desconectar todos os geradores tão logo ocorra um ilhamento. Tipicamente, é necessário detectar uma situação de ilhamento em menos de dois segundos, dependendo, principalmente, do tempo de operação dos religadores automáticos. Os métodos mais comuns e baratos para detectar ilhamento compreendem relés baseados em medidas de freqüência (sub/sobrefrequência, taxa de variação de frequência e "salto de vetor") e o relé de tensão. No entanto, esses relés podem falhar se os níveis de desbalanço de potência ativa e reativa no subsistema ilhado forem pequenos. Portanto, o objetivo dessa dissertação é investigar a potencialidade de novos sinais para detectar ilhamento de geradores síncronos distribuídos, como forma de substituição ou complementação aos dispositivos de proteção anti-ilhamento convencionais. Os sinais analisados neste trabalho são taxa de variação da potência ativa (dP/dt), a relação Volts por Hertz (V/Hz), a variação da impedância (Z) medida no ponto de acoplamento comum (PAC), e a diferença angular ('delta' 'teta') entre as tensões medidas no PAC e na subestação. A investigação é baseada no levantamento de um conjunto de curvas relacionando tempo de detecção e desbalanço de potência ativa/reativa e nas zonas de não detecção, as quais fornecem os pontos de operação para os quais o relé em estudo falha na detecção do ilhamento. As curvas e as zonas são obtidas através de simulações de transitórios eletromagnéticos trifásicas considerando diferentes perfis de carga-geração na rede ilhada. Os resultados obtidos mostram que os sinais analisados têm um grande potencial para esse tipo de aplicação, porém são sujeitos à atuação indevida no caso da ocorrência de eventos que não sejam ilhamentos na rede de distribuição. Assim, uma análise de falsa operação também é conduzida e são propostas melhorias para minimizar e/ou eliminar a atuação indevida desses relés aqui investigados / Abstract: Synchronous generators connected to distribution power networks are likely to operate islanded following faults clearance in the system. Islanding occurs when a portion of the distribution system becomes electrically isolated from the substation, yet it continues energized by distributed generators connected to the islanded system. Utilities and standards recommend the disconnection of distributed generators immediately after islanding occurrences, otherwise it can lead to a number of problems to the generator and the connected loads. Typically, it is required to detect an islanding situation faster than two seconds after the island formation, depending, mainly, on the operation time of automatic reclosers. The most common and economical methods to detect islanding include the relays based on measures of frequency (under/over frequency, rate of change of frequency and vector surge) and voltage. However, these relays can fail if the active and reactive power imbalance levels in the islanded system are small. Therefore, the objective of this thesis is to investigate the potentiality of new signals to detect islanding of distributed synchronous generators, as replacement or complement to conventional protection anti-islanding devices. The signals analyzed in this research are the rate of change of generator active power (dP/dt), the ratio Volts per Hertz (V/Hz), impedance variation (Z) measured at the point of common coupling (PCC), and the angular difference ('delta' 'teta') between the voltage angle measured at the PCC and at the utility substation. The investigation is based on a set of curves, which relate time of islanding detection and active/reactive power imbalance and on the nondetection zones, which provide the operating points for which the relay fails to detect the islanding. These are obtained through electromagnetic transient three-phase simulations considering different profiles of generation-load in the islanded network. The results show that the signals analyzed have a huge potential for this type of application, however, their performance can decrease in case of occurrence of non-islanding events in the distribution system. Thereby, an analysis of false operation is conducted in order to propose improvements to minimize and/or to eliminate improper behavior of these relays / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Page generated in 0.0645 seconds