11

Modelo de simulação estocástica da demanda de água em edifí­cios residenciais. / Stochastic simulation model of water demand in residential buildings.

Tiago de Vasconcelos Gonçalves Ferreira 19 January 2018 (has links)
Ao longo dos anos, pesquisadores têm liderado estudos com o objetivo de investigar o perfil de consumo de água em edifícios, os quais contribuem para o conhecimento no que tange ao correto dimensionamento dos sistemas prediais. No contexto dos métodos para a caracterização das solicitações, as rotinas comumente empregadas para a obtenção das vazões de projeto foram, em sua maioria, propostas na metade do século XX. Estes modelos precisam ser revisados e readequados para a realidade de conservação existente atualmente. Nos últimos anos, alguns estudos propuseram modelos de simulação com foco de aplicação em sistemas prediais de distribuição de água, devido ao comportamento aleatório e temporal das solicitações neste tipo de sistema. Neste trabalho foi proposto um modelo de simulação estocástica da demanda de água em edifícios residenciais, que contemplou a modelagem comportamental dos usuários e a interação destes com o sistema, a fim de aperfeiçoar o processo de dimensionamento dos sistemas prediais de distribuição de água. Para isto, foram revisadas as bases teóricas de modelos propostos anteriormente com interesse de identificar aspectos significativos e construir um novo modelo, que mesclou a modelagem comportamental dos usuários e do sistema hidráulico. Para a obtenção dos valores das variáveis intervenientes, foi feita uma consulta em trabalhos dentro do contexto nacional e uma coleta de dados em campo. Os resultados da pesquisa em campo mostraram a correlação entre a rotina dos usuários e o volume de água consumida e um aumento médio de 192% do valor da vazão de projeto obtida pelo Método dos Pesos Relativos quando comparada com as vazões obtidas no medidor dos apartamentos monitorados. Em posse de todos os dados de entrada, foram feitas diferentes simulações que variaram o tipo do chuveiro instalado nos apartamentos. Quando comparadas as vazões obtidas pela simulação e pelo Método dos Pesos Relativos, em todos os componentes do sistema, a redução da vazão de projeto variou entre 4% e 61%. Em termos de consumo de material, a redução ficou entre 25% a 63%. / Over the years, researchers have been conducting studies to investigate the water consumption profile in buildings, which contribute to the knowledge regarding the correct sizing of the building hydraulic systems. In context of the methods for characterization of requests, the routines commonly used to obtain the project flows were mostly proposed in mid-20th-century. These models need to be revised and adapted to nowadays water conservation reality. In recent years, some studies have proposed simulation models with application focus in water distribution systems, due to the random and temporal behavior of the requests in this type of system. In this study, a stochastic simulation model of water demand in residential buildings has been proposed, which contemplated the behavioral modeling of users and their interaction with the system, in order to improve the design process of water distribution systems. For such, the theoretical bases of previously- proposed models for the identification of significant aspects for the construction of a new model were revised, which merged the behavioral modeling of users and the hydraulic system. In order to obtain the values of intervening variables, fieldworks and a review was conducted in papers which treated about the Brazilian context. The results of the data collected on the fieldworks show a correlation between the routine of users and the volume of water consumed. Besides, there was an average increase of 192% in the value of the project flow rate obtained by the Brazilian Standard Method when compared with the flows obtained in the monitored apartments. Considering the input data in the model, different simulations - with several different types of showers installed in the apartments - were made. When comparing the flows obtained by the simulation and the Brazilian Standard Method, in all components of the system, the reduction of the project flow varied between 4% and 61%. In terms of material consumption, the reduction was between 25% and 63%.
12

Estudo comparativo entre a aplicação de sistemas dedicados e a utilização de controladores lógico-programáveis na automação de sistemas prediais. / Comparative study between among application os dedicated systemas and the use of programmable logic controllers on building automations systems.

Marco Antonio Baptista de Sousa 30 March 2004 (has links)
O trabalho enfoca a automação predial, procurando analisar, comparativamente, a utilização de tecnologias convencionais e equipamentos empregados na automação de processos industriais. Através de um estudo de caso, efetuou-se uma descrição dos principais sistemas prediais possíveis de serem automatizados em um edifício, efetuando-se uma avaliação comparativa entre os sistemas convencionais e os baseados na automação de processos, permitindo o uso mais eficiente dos insumos prediais, além de aumentar o conforto e a segurança de seus ocupantes. Verificou-se um grande potencial de aplicação dos sistemas de automação de processos industriais, para implementação alternativa nos sistemas de automação predial. / This research focuses building automation, analyzing comparatively the use of conventional technologies and other equipments commonly applied in industrial processes. Through a case study, a description of mainly building systems that are feasible to be automated in high technology buildings has been made, including a comparative evaluation of mainly building systems based on conventional systems and automation process, allowing the most efficient use of building resources, beyond to increase the users’ comfort and security. It was verified a great potential for applications of industrial processes automation systems, as an alternative implementation in building automation systems.
13

Operação de sistemas de aquecimento solar de água com controle de vazões em coletores planos. / Operation of solar water-heating systems with flow control on flat plate collectors.

Laerte Bernardes Arruda 01 July 2004 (has links)
O presente trabalho consiste em um estudo experimental sobre o efeito do controle de vazões em sistemas de aquecimento solar de água em instalações com grande número de coletores, onde o gradiente de temperatura não é suficiente para circular a água por termossifonagem. Foi avaliado o desempenho de todo o sistema sob diferentes condições de insolação, de vazão, de diferenciais de temperatura entre os coletores e o reservatório, em regime não permanente. Os resultados experimentais foram comparados com a equação de rendimento dos coletores, para condições de regime quase permanente, obtida segundo a norma da ABNT - NBR 10184/1988. Os ensaios foram realizados em duas baterias de testes, cada uma composta de dois coletores industrializados e um reservatório isolado termicamente. Em uma destas baterias, o fluxo de água entre os coletores e o reservatório ocorreu por termossifonagem, isto é, sem nenhuma restrição à vazão; na outra bateria, a vazão foi controlada por um registro e uma bomba hidráulica. Um sistema de automação coletou e processou os dados de forma a permitir a execução dos controles desejados, inclusive a simulação de consumo de água quente. O sistema com circulação natural, isto é, por termossifão, demonstrou ter uma grande habilidade de se adaptar à disponibilidade de energia com as temperaturas da água armazenada, por meio da otimização da velocidade da troca de calor. Foi desenvolvido, tomado como referência o escoamento por termossifão, um modelo de operação para sistemas diretos ativos que calcula a vazão com base no monitoramento das temperaturas das extremidades das tubulações que interligam o reservatório e os coletores, temperatura do ar, radiação solar disponível e vazão no instante anterior. O modelo foi testado experimentalmente e a operação do sistema ativo resultou em significativa melhora a eficiência. / The focus of this work is the experimental study of the effect of water control discharge in solar water-heating systems with a large number of collectors where the temperature gradient is not sufficient for thermosiphon water circulation. The performance of the system was evaluated under different conditions of solar radiation, flow rate, temperature differential between solar collectors and the storage tank and under transient conditions. The results were compared to a collector\'s performance equation of the quasi-steady-state model according to ABNT-NBR 10184/1988 standard. The tests were carried out on two systems each one constituted of two manufacturing collectors and one thermal tank. In one of these systems the flow between the collectors and storage occurred by thermosiphoning, i.e., by natural convection and without discharge restrictions. In the other, the flow control was done by means of a valve and a pump. In order to allow the execution of the desired controls, including hot water consumption, data were colleted and controlled through an automation system. The system of natural circulation shows a great ability to adaptation of disposal energy with water temperature stored, through velocity of heat exchange optimization. An operation model was developed, having thermosiphoning water circulation as reference, for active direct circulation systems that calculate the discharge taking into consideration the monitoring of the differential temperature between solar collectors and the storage tank, the air temperature, solar radiation available and the flow rate on previous time interval. This model was experimentally tested and resulted in a significant improvement in performance of the system operation.
14

Regras de verificação e validação de modelos BIM para sistemas prediais hidráulicos e sanitários. / Rules of verification and validation of BIM models for sanitary hydraulic building installations.

Carolina Yumi Kubo Takagaki 10 June 2016 (has links)
A complexidade das atuais edificações e, consequentemente, a divisão dos projetos em especialidades e subsistemas evidenciam as dificuldades do coordenador de projetos em gerenciar todo o processo de projeto. Há necessidade de um fluxo contínuo de troca de informações e de comunicação entre os envolvidos. A prática do BIM (Building Information Modeling) e o emprego de suas ferramentas computacionais propiciam aos projetistas a agilidade e precisão no desenvolvimento do projeto, uma vez que possibilita, por exemplo, uma visualização da interação de todos os subsistemas do edifício. No entanto, o cenário atual da tecnologia não provê ferramentas para todos os fluxos de trabalho necessários, e quando fornece, nem sempre o software disponível segue as normas específicas para determinada aplicação em certo país. As normas técnicas estabelecem requisitos e recomendações relativos ao projeto e devem ser observadas por projetistas para a segurança e qualidade das edificações. Neste sentido, o objetivo desta pesquisa é desenvolver regras de verificação e validação de modelos BIM para sistemas prediais com base em normas técnicas brasileiras, tais como a de sistemas prediais de água, de esgoto sanitário e de águas pluviais. O método empregado considera o levantamento das recomendações normativas e suas respectivas transformações em regras que possam ser verificadas automaticamente por meio de programas de computador. O programa adotado foi o software Solibri Model Checker (SMC), que faz uso de modelos em Industry Foundation Classes (IFC). Os resultados mostram que regras simples de comparação e relacionadas a propriedades de cada elemento são possíveis de serem parametrizadas no SMC e têm resultados sólidos de fácil visualização, o que permite uma correção mais rápida e dinâmica por parte dos projetistas e coordenadores de projeto. Para regras mais complexas, necessitou-se da criação de ferramentas paralelas ao SMC. Constata-se que o SMC ainda é incompleto quando se trata da análise de projetos de sistemas prediais hidráulicos e sanitários, porém é possível desenvolvê-las uma vez que o modelo em IFC pode conter todas as informações necessárias às análises. Assim, verifica-se a necessidade de que os projetos BIM contenham as informações e obedeçam a padrões de modelagem para que possam ser utilizados na verificação de regras de modo eficiente. Por fim, os resultados desta pesquisa contribuem para o emprego do BIM no desenvolvimento e análise de projeto de sistemas prediais hidráulicos e sanitários com maior precisão, agilidade e qualidade. / The complexity of existing buildings and, consequently, the division of projects and sub-specialties highlight the difficulties the project coordinator to manage the entire design process. There is a need for a continuous flow of information exchange and communication among stakeholders. The practice of BIM (Building Information Modeling) and the use of their computational tools provide designers the speed and accuracy in the development of the project, as it enables, for example, a preview of the interaction of all building subsystems. However, the current technology landscape does not provide tools for all to workflows required, and when it does, they do not always follow standards a specific application in a given country. The technical standards contain requirements and recommendations relating to the project and must be observed by designers for the safety and quality of the buildings. In this sense, the objective of this research is to develop procedures for verification and validation of BIM models for building systems based on Brazilian technical standards, such as building systems for water, sanitary sewer and storm water. The employed method considers the collection of policy recommendations and their changes in rules that can be automatically checked using computer programs. The adopted program was Solibri Model Checker software (SMC), which makes use of models in Industry Foundation Classes (IFC). The results show that simple comparison rules and related properties of each element are able to be parameterized in the SMC and have solid results for easy viewing, allowing faster correction and dynamic on the part of designers and design engineers. For more complex rules the creation of parallel tools to SMC is needed. It appears that the SMC is still incomplete when it comes to the analysis of hydraulic and sanitary building systems projects, but you can develop them as the model in IFC can contain all the necessary information to the analysis. Thus, there is a need that the BIM projects contain the information and comply with standards for modeling which can be used to verify rules efficiently. Finally, the results of this research contribute to the use of BIM in the development and design analysis of hydraulic building systems and toilets with greater accuracy, speed and quality.
15

Critérios de avaliação de sustentabilidade ambiental dos sistemas prediais hidráulicos e sanitários em edifícios de escritórios. / Assessment criteria for environmental sustainability on office buildings hydraulic and sanitary systems.

Andreza Kalbusch 06 July 2006 (has links)
A definição de desenvolvimento sustentável da World Commission on Environment and Devolopment aponta para um desenvolvimento econômico e social capaz de atender às necessidades desta geração, não comprometendo o atendimento das necessidades das gerações futuras. A gestão do uso da água, enquanto estratégia para preservação deste recurso, vem ao encontro do conceito de desenvolvimento sustentável, uma vez que pretende garantir que haja água disponível para as gerações futuras e que, sem este recurso, não há possibilidade de vida no planeta. Em relação a edifícios, a conservação da água pode ser alcançada através do emprego de práticas e de tecnologias que levem a uma utilização mais sustentável deste recurso, sem que haja interferência no conforto dos usuários. O presente trabalho pretende ser uma contribuição e um incentivo às práticas de conservação da água no ambiente construído, além de ser uma contribuição para a aplicação dos conceitos de sustentabilidade ambiental no projeto e execução de sistemas prediais hidráulicos e sanitários na construção civil brasileira. Para isso, detalha-se a maneira como alguns sistemas de avaliação de sustentabilidade ambiental de edifícios de escritórios avaliam itens relacionados aos sistemas prediais hidráulicos e sanitários e ao uso da água. O objetivo é aprofundar os critérios de avaliação de sustentabilidade ambiental dos sistemas prediais hidráulicos e do uso da água propostos para edifícios de escritório com base na documentação técnica e normalização brasileira consultadas. / The World Commission on Environment and Development definition for sustainable development points towards a social and economic development capable of taking care of the necessities of this generation without compromising the necessities of future generations. Water management creates strategies that secure the preservation of this resource and also fits the concept of sustainable development, since it intends to ensure the availability of water for generations to come and understands that without this resource there is no possibility of life on Earth. When it comes to buildings, water preservation is possible through the application of practices and technologies that will lead to a more sustainable use of this resource, without interfering on the daily activities of users and their needs and comfort. The purpose of this study is promoting actions regarding water preservation in buildings and contributing to the application of environmental sustainability concepts in hydraulic and sanitary systems on the Brazilian construction industry. For that reason it contains the details and the evaluation criteria on how some of the environmental assessment methods actually evaluate items that are related to hydraulic and sanitary systems and water usage. Therefore its main objective is to study the evaluation criteria for environmental sustainability on hydraulic and sanitary systems and water use for office buildings based on the consulted technical documentation and relevant Brazilian standards.
16

Avaliação do desempenho do sistema de descarte de água de chuva coletada em coberturas de três diferentes tipos de materiais / Performance assessment of disposal units from Rainfal collection system from roofs made by three different materials

ROCHA, Bárbara Cristina Castro de Melo 20 May 2010 (has links)
Made available in DSpace on 2014-07-29T15:01:53Z (GMT). No. of bitstreams: 1 barbara cristina castro.pdf: 4909158 bytes, checksum: 97c33d72b85f6014d478bd8aea66f69b (MD5) Previous issue date: 2010-05-20 / The water shortage has become one of the world's main problems, leading to the development of new technologies and practices of water conservation. In order to obtain more effective solutions to solve this problem, new researches have been carried on to create hydraulic and sanitary systems more sustainable or, at least, system that causes less impact to the environment. Among the technologies economically available on water conservation in buildings, the use of rainfall collected from roofs can be of great potential to become a viable solution. The objective of this work is to study the ideal conditions for the disposal process of rainfall collected from three roofs made of different materials: metal, asbestos cement and ceramic tiles, located nearby, with the purpose of identifying both the ideal volume of disposal and the achievement of water quality standards, so that it becomes feasible for future uses. To do so, experimental units were installed to collect, dispose and store rainwater from three buildings located within the area of the School of Civil Engineering at Federal University of Goiás. After monitoring the volume of disposal correlating it with the quality assessment of the rainwater collected in each type of roof and with the rainwater collected directly from the atmosphere, the processes were evaluated based on the observed parameters and on the criteria established by the NBR 15,527 (ABNT, 2007), in order to identify the best way to implement disposal units in rainwater usage systems in buildings. It had been found that the rainwater disposal process is essential for obtaining water with better quality from these systems. It had also been observed that the disposal based on time does not seem to be securely enough to guarantee the necessarily quality in the collected water. Among the roofs in study, the metal roof gave water with the best quality after the disposal of the first 100 liters collected (this corresponds to 1,33 mm of accumulated rainfall in the area of study). It is presumed that the metal roof is the best choice to collect rainfall water because it is smoother and has almost no overlapping tiles. On the other hand, the 2 mm rainwater disposal suggested by NBR 15,527 (ABNT, 2007) has shown to be insufficient to guarantee the safe and secure use of the collected water to both users and hydraulic installations, requiring for this purpose the installation of at least a simplified water treatment unit. / A escassez de água tem se tornado um dos grandes problemas mundiais, o que vem levando a necessidade de estudos de novas metodologias e técnicas de conservação de água. Visando a obtenção de soluções eficazes para minimizar esse problema, dentro do ambiente construído, vários estudos estão sendo realizados em busca de sistemas prediais hidráulicos e sanitários mais sustentáveis ou que promovam menor impacto ambiental. Dentre as possíveis tecnologias que visam à conservação de água em edificações, os sistemas de aproveitamento de águas de chuva podem ser uma alternativa viável e de grande potencial para a solução desse problema. O objetivo deste trabalho consiste em estudar as condições ideais do processo de descarte da água da chuva coletadas em três coberturas de diferentes tipos de materiais: metálico, cimento amianto e barro, situadas em uma mesma localidade, visando identificar o volume ideal de descarte e padrões de qualidade de água que viabilizem sua posterior utilização. Para tanto, foram instaladas unidades experimentais de captação, descarte e armazenamento de água de chuva em três edificações na área da Escola de Engenharia Civil da Universidade Federal de Goiás. Após o monitoramento do volume de descarte correlacionado com a avaliação da qualidade da água de chuva coletada em cada tipo de cobertura e, com a água de chuva coletada diretamente da atmosfera, foram avaliados os processos com base nos parâmetros observados e nos critérios estabelecidos pela NBR 15.527 (ABNT, 2007), de forma a identificar a melhor forma de viabilizar a implantação de unidades de descarte em sistemas de aproveitamento de água de chuva em edificações. Foi verificado que o processo de descarte de água de chuva é essencial para a obtenção de água de melhor qualidade nestes sistemas. Também foi possível observar que o descarte por tempo não se mostrou suficiente para garantir a captação de água de chuva de qualidade assegurada. Dentre os telhados avaliados, a cobertura de telhas metálicas proporcionou a obtenção de uma água de melhor qualidade após o descarte dos primeiros 100 litros coletados (correspondente a 1,33 mm de chuva para as áreas de contribuição estudadas). Presume-se que este resultado tenha sido obtido devido a sua superfície de contato ser mais lisa que os outros telhados estudados e, também de não haver sobreposição de telhas. Por outro lado, os 2 mm de descarte de água de chuva, sugeridos pela NBR 15.527 (ABNT, 2007), não se mostraram suficientes para garantir que a água de chuva coletada possa ser utilizada sem que haja risco aos usuários e às instalações hidráulicas, exigindo para tanto ao menos um tratamento simplificado.
17

Modelos para a tomada de decisão quanto ao tipo de sistema predial de água não potável. / Models for decision-making in relation to the type of non-potable water system.

Dias, Christine Miranda 28 April 2017 (has links)
Os sistemas prediais de água não potável podem ser do tipo centralizado, quando os efluentes oriundos de diversas edificações são coletados e transportados para um único local de tratamento e redistribuídos para um conjunto de residências; ou descentralizado, quando a coleta, o tratamento e o transporte dos efluentes ocorrem próximos ao local de produção. Porém, tanto o sistema centralizado quanto o descentralizado possui particularidades que os fazem interessantes ou não em aspectos sociais, econômicos e ambientais. Desta forma, o objetivo principal desta pesquisa foi formular modelos matemáticos que permitissem comparar o sistema centralizado com o descentralizado. Para o desenvolvimento do estudo realizou-se uma revisão bibliográfica com o intuito de coletar informações sobre as principais variáveis que interferem na tomada de decisão de cada tipo de sistema. A partir dos princípios da Programação Linear Inteira foram formulados três modelos que permitiram encontrar qual tipo de sistema apresenta o menor custo total acumulado, quanto é o valor desse custo ao longo do tempo e quantos sistemas são necessários instalar para atender a uma demanda específica. Com base nos dados da literatura consultada, o sistema centralizado apresentou-se mais vantajoso do que os sistemas descentralizados quanto aos custos de implantação, de manutenção e de operação considerando uma vida útil de 20 anos. Todavia, verificou-se que a escolha do sistema mais viável não deve se concentrar apenas nos custos, mas também devem ser consideradas variáveis qualitativas. Deste modo, as formulações gerais dos modelos permitem a inserção de outras variáveis de decisão e restrições para aprimorar a tomada de decisão quanto ao tipo de sistema predial de água não potável a ser implantado. / Non-potable water systems may be of the centralized type when effluents from several buildings are collected and transported to a single treatment site and redistributed to a set of residences; or decentralized, when the collection, treatment and transportation of the effluent occurs near the place of production. However, both the centralized and decentralized systems have particularities that make them interesting or not in social, economic and environmental aspects. In this way, the main objective of this research was to formulate mathematical models that allowed to compare the centralized system with the decentralized one. For the development of the study a bibliographic review was carried out in order to collect information on the main variables that interfere in the decision making of each type of system. From the principles of Linear Programming, three models were formulated that allowed to find out which type of system has the lowest cumulative total cost, what is the value of this cost over time and how many systems are needed to meet a specific demand. Based on the data of the literature, the centralized system was more advantageous than the decentralized systems in terms of the implantation, maintenance and operation costs considering a useful life of 20 years. However, it has been found that the choice of the most viable system should not only focus on costs but should also be considered as qualitative variables. In this way, the general models formulations allow the insertion of other decision variables and constraints to improve the decision making regarding the type of non-potable water system to be implanted.
18

Avaliação durante operação de sistemas prediais de água não potável. / Evaluation during operation of non-potable water building systems.

Castilho, Carolina Paula de 21 January 2016 (has links)
A preocupação mundial com o cenário de escassez do recurso natural \"água\" é sintetizada no slogan adotado pela WateReuse Research Foundation em campanha pelo reuso de água: \"Water... it\'s too valuable to be used just once\". Progressivamente tem-se melhorado os processos de gestão da água, com controle de desperdício, procedimentos e utilização de fontes alternativas de abastecimento, não apenas na escala dos sistemas públicos, mas nos sistemas prediais. No Brasil, seguindo esta tendência global, existem iniciativas independentes de sistemas prediais de água não potável sendo instalados em edifícios residenciais e comerciais. Estas iniciativas, no entanto, contam hoje com pequeno respaldo técnico normativo, diretrizes ou legislação que orientem gestores, executores e profissionais sobre as práticas adequadas de implantação, gestão e monitoramento deste tipo de sistema, colocando em risco a segurança dos usuários e o sucesso da tecnologia. Considerando-se que para produzir um edifício de qualidade é fundamental atender às necessidades dos usuários, adequando as soluções ao uso que será feito do produto, a Avaliação Durante Operação (ADO) do edifício apresenta-se como uma ferramenta adequada para a análise da situação atual do sistema. Inserindo-se neste contexto, esta pesquisa tem o objetivo de propor uma ferramenta que auxilie a avaliação de desempenho de sistemas prediais de água não potável durante sua operação em edifícios residenciais, no que se refere à operação e manutenção. Para tanto, foi realizado levantamento bibliográfico sobre sistemas prediais de água não potável, tratamentos de água disponíveis e avaliação de desempenho. Seguindo a metodologia de ADO, foram realizados estudos de casos em edifícios residenciais para levantamento de dados atuais de desempenho. Ao término da análise dos casos selecionados, foi possível validar a ferramenta proposta e constatar que a falta de capacitação técnica, normas técnicas e legislações específicas que orientem projetistas, executores, gestores e usuários e padronizem os sistemas prediais de água não potável contribui para o cenário encontrado nos estudos, caracterizado por sistemas que operam com desempenho inferior ao adequado para atender às necessidades e garantir a segurança de seus usuários. / The global concern with the scenario of increasing natural resource scarcity is synthesized in the slogan adopted by WateReuse Research Foundation for a reuse campaign: \"Water... it\'s too valuable to be used just once.\" Progressively, the water management processes have been improved, by controlling waste, procedures and use of alternative sources of water supply, not only at the city level but also individually. In Brazil, following this global trend, there are independent initiatives of non-potable water systems being installed in residential and commercial buildings. These initiatives, however, have today little technical normative support, guidelines or legislation to orientate managers, performers and professionals on the appropriate practices for deployment, management and monitoring of this type of system, endangering the safety of users and the success of technology. Considering that to produce a quality building it is critical to meet the user\'s needs, suiting the solutions according to the product use, the evaluation during operation (EDO) presents itself as adequate tool for analyzing the current situation and proposing improvements on the system performance. In this context, this study aims to propose a tool that assists the performance evaluation of non-potable water systems during its operation in residential buildings, regarding the design, implementation, operation and maintenance. In order to do that, it was performed bibliographical survey on nonpotable water systems, available water treatments and performance evaluation. Following the EDO methodology, case studies were conducted in a sample of residential buildings for current performance data collection. Upon completion of the analysis of selected cases, the proposed tool was validated and it was found that the lack of technical training, technical standards and specific legislation to guide designers, performers, managers and users, and to standardize the non-potable water systems contributes to the scenario found in the case studies, characterized by systems operating with performance unsuited to meet the needs and ensure the safety of its users.
19

Análise e caracterização de soluções acústicas para mitigar os ruídos oriundos de instalações hidrossanitárias prediais. / Analysis and characterization of acoustical solutions to mitigate the noise from hydrossanitary systems in buildings.

Rocha, Raquel Rossatto 27 March 2018 (has links)
O ruído excessivo é considerado problema de saúde pública devido ao seu impacto a saúde humana. Nas edificações residenciais, os ruídos emitidos por instalações hidrossanitárias são maioria nas reclamações dos usuários. Neste contexto, destaca-se a necessidade do controle acústico em edificações residenciais, em específico deste estudo, para o controle do ruído hidrossanitário em instalações prediais. A norma NBR 15575: 2013 estabelece parâmetros para que os ruídos gerados por instalações hidrossanitárias não produzam níveis de pressão sonora elevados no interior dos dormitórios. Os níveis elevados provocam uma percepção auditiva desagradável e podem gerar constrangimentos entre vizinhos, devido à falta de privacidade. O objetivo deste artigo é avaliar e comparar os resultados de possíveis soluções acústicas para mitigar os níveis de pressão sonora gerados pelas instalações hidrossanitárias prediais, devido o acionamento de descargas de vasos sanitários e abertura de torneiras. Foram realizadas medições de níveis de pressão sonora conforme a norma ISO 16032: 2004 adaptada para laboratório em câmara de ensaios acústicos hidrossanitários do Instituto de Pesquisas Tecnológicas (IPT) para nove amostras de envelopamento acústico. Os resultados técnicos encontrados através das grandezas LZeq,nT, LAeq,nT e LASmax,nT foram analisados e comparados para cada amostra medida no tubo envelopado e no tubo aparente. Para as amostras analisadas, a maioria das amostras apresenta ? L >= 20 dB no acionamento da descarga do vaso sanitário e ? L >= 10 dB para o ruído oriundo da abertura da torneira. Através da estimativa custo-benefício, verificou-se que a amostra C possui a melhor relação entre as amostras estimadas. / Excessive noise is considered a public health problem due to its impact on human health. In residential buildings, the noises emitted by hydrosanitary are the source of most complaints from users. In this context, we highlight the need for acoustic control in residential buildings, in the specific case of this work, for the control of hydrosanitary systems noise in building. The standard NBR 15575: 2013 establishes parameters for the noises generated by hydrosanitary systems do not produce highs sound pressure levels inside the bedroom. When these levels are high, they cause a nasty hearing perception and can generate constraints between neighbors, due to the lack of privacy. The goal of this dissertation is to evaluate and analyze the results of possible acoustic solutions to mitigate the sound pressure levels generated by hydrosanitary systems, due to the triggering of discharge activation of toilets and tap opening. For this, measurements of sound pressure levels as ISO 16032: 2004 adapted to laboratory in acoustic testing environment hydrosanitary Instituto de Pesquisas Tecnológicas (IPT) to nine samples. Evaluated and compared the technical results found through the variable, LZeq,nT, LAeq,nT e LASmax,nT, for each sample as the tube enveloped and apparent tube. The results for the samples analysed are satisfactory, since most samples reduce more than 20 dB for noise generated due to the discharge activation and 10 dB for noise from the tap opening. Through the cost-benefit analysis, it was found that the sample C has the best relation between estimated samples.
20

A medição setorizada como instrumento de gestão da demanda de água em sistemas prediais - estudo de caso: Programa de Uso Racional da Água da Universidade de São Paulo. / Submetering as an instrument of water demand management in building systems – case study: Water Conservation Program of the University of São Paulo.

Tamaki, Humberto Oyamada 03 April 2003 (has links)
No presente trabalho é estudada a utilização da medição setorizada como instrumento de gestão da demanda de água em sistemas prediais. Para tanto, a caracterização dos medidores e a análise das interações dos elementos de medição com o sistema de suprimento de água fria e de equipamento sanitário são realizados a partir de um enfoque sistêmico e de desempenho. Considerando a coleta de melhores informações, qualitativamente e quantitativamente acerca do consumo, essencial para a gestão da demanda de água, e especialmente em um contexto de ações de conservação, neste trabalho levantou-se os sistemas de telemedição. Apresentou-se uma proposta de planejamento de implantação da medição setorizada e quais elementos que devem ser observados para a gestão da demanda. Para subsidiar as avaliações, realizou-se o estudo de caso da medição setorizada na Universidade de São Paulo, no qual foi possível verificar a importância da sua aplicação e os resultados extremamente positivos que justificaram sua implantação. / In this work it is studied the use of submetering as an instrument of water demand management in building systems. In such way, the characterization of the meters and the analysis of the interactions of its elements with the building hydraulical system are carried on a systemic approach and performance analysis of the proposal. Considering the collection of better information of water consumption essential for the water demand management, especially in a conservation context, it was searched out the systems and the technologies of remote metering. A proposal for the planning of the submetering implantation was showed, as well as the elements that should be considered for the demand management. To make the evaluations, the case study of the submetering program in the University of São Paulo was accomplished, in which it was possible to verify the importance of its application and the extremely positive results that had justified its implantation.