• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 122
  • 108
  • 29
  • 14
  • 9
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 4
  • 4
  • 3
  • Tagged with
  • 351
  • 211
  • 109
  • 78
  • 66
  • 56
  • 55
  • 52
  • 51
  • 48
  • 48
  • 47
  • 45
  • 43
  • 42
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

A simplified finite element model for time-dependent deflections of flat slabs

Cloete, Renier. January 2005 (has links)
Thesis (M.Eng.(Structural Engineering))--University of Pretoria, 2004. / Summary in Afrikaans. Includes bibliographical references.
132

Punching shear strength of interior and edge column-slab connections in CFRP reinforced flat plate structures transferring shear and moment /

Zaghloul, Ashraf, January 1900 (has links)
Thesis (Ph.D.) - Carleton University, 2007. / Includes bibliographical references (p. 351-372). Also available in electronic format on the Internet.
133

A neural network approach for predicting the structural behavior of concrete slabs /

Tully, Susan Hentschel, January 1997 (has links)
Thesis (M. Eng.)--Memorial University of Newfoundland, 1997. / Bibliography: leaves 103-108.
134

Behavior and modeling of reinforced concrete slab-column connections

Tian, Ying, January 1900 (has links)
Thesis (Ph. D.)--University of Texas at Austin, 2007. / Vita. Includes bibliographical references.
135

Análise da confiabilidade da ligação laje-pilar interno sob punção de acordo com a NBR-6118:2014 / Reliability analysis of the slab-column intersection under puching according to NBR 6118:2014

Silva, Gustavo Ribeiro da January 2017 (has links)
As demandas do mercado da construção civil têm exigido vãos cada vez maiores e ao mesmo tempo alturas cada vez menores das vigas. Isto tem levado muitos projetistas à adoção da solução do pavimento em laje lisa em concreto armado ou protendido. No entanto, a ausência das vigas torna possível a ruptura das lajes por puncionamento junto aos pilares. A norma NBR-6118:2014 prescreve as disposições para o projeto de lajes sob punção. O trabalho proposto teve como objetivo principal a análise da confiabilidade da ligação laje-pilar interno sob o efeito da punção em lajes que se apoiam diretamente sobre pilares de acordo com a NBR-6118:2014. Primeiramente, com o intuito de se entender melhor o fenômeno da punção, realizou-se uma breve revisão bibliográfica, identificando os principais parâmetros que influenciam na resistência da ligação, assim como os principais métodos de análise e trabalhos realizados na área. Em seguida, estudou-se o software de análise em elementos finitos ANSYS (Analysis Systems Incorporated), especificamente a ferramenta UPF (User Programmable Features), que foi utilizada para adoção de um modelo constitutivo para o concreto. Utilizando o software, foram modeladas lajes estudadas por outros autores, visando a validação do modelo numérico. Para o estudo da confiabilidade foi dimensionado um conjunto de lajes lisas seguindo as prescrições da NBR 6118:2014. A análise da confiabilidade foi realizada utilizando a ferramenta PDS (Probabilistic Design System), empregando o método de simulação numérica de Monte Carlo com amostragem por Latin Hypercube. Por fim, determinou-se o índice de confiabilidade em cada projeto e realizaram-se análises paramétricas com as variáveis adotadas no trabalho. Os resultados obtidos mostraram que as lajes lisas sem armadura de cisalhamento projetadas segundo a NBR 6118:2014 obtiveram, em sua maioria, índices de confiabilidade adequados. Porém, para as lajes lisas com armadura de cisalhamento, o índice de confiabilidade foi, em grande parte, menor que o índice de confiabilidade alvo adotado. / The demands of the construction market have required increasingly large spans while diminishing of the beam heights. This has led many designers to adopt the pavement solucion of reinforced or prestressed concrete flat slab. However, the absence of the beams makes it possible to slabs failure by punching shear. The Standard NBR-6118: 2014 prescribes the requirements for the design of slabs under punching. The aim of this work was to analyze the reliability of the internal slab-column intersection under punching in slabs supported directly on columns according to NBR-6118: 2014. Firstly, in order to better understand the punching phenomenon, a brief bibliographic review was carried out, identifying the main parameters that influence the connection strength, as well as the main methods of analysis and published in the area. Then, the finite element analysis software ANSYS (Analysis Systems Incorporated), specifically the UPF (User Programmable Features) tool, was used to adopt a concrete constitutive model. Using the software, slabs studied by other authors were modeled, aiming at the validation of the numerical model. For the reliability study, a set of flat slabs was designed following the requirements of NBR 6118: 2014. The reliability analysis was performed using the PDS (Probabilistic Design System) tool, using the Monte Carlo numerical simulation method with Latin Hypercube sampling. Finally, the reliability index was determined in each project and parametric analyzes were performed with the variables adopted in the study. The results from this study show that the flat slabs without shear reinforcement designed according to NBR Standarts obtained appropriate reliability index. However, for the flat slabs with shear reinforcement, the reliability index, in most cases, did not achieve the target reliability index.
136

Customização do software ANSYS para análise de lajes de concreto protendido pelo método dos elementos finitos / ANSYS software customization for analysis of prestressed concrete slabs by finite element method

Alarcon Ayala, Igor Carlos January 2017 (has links)
A necessidade por aprimorar sistemas e materiais na indústria da construção civil derivou no uso da protensão como uma alternativa de reforço para estruturas de concreto. As vantagens técnicas e econômicas encontradas no projeto e execução de estruturas de concreto fizeram com que este sistema venha ganhando preferência frente ao sistema convencional de concreto armado. Nesse contexto, este trabalho visa contribuir desenvolvendo um modelo computacional no software ANSYS, versão 16.0, por meio da ferramenta de customização UPF (User Performance Features), para o estudo de lajes de concreto armado e protendido, com ou sem aderência. A implementação do modelo computacional, baseado no método dos elementos finitos, tem ênfase na não-linearidade física dos materiais através de um modelo elasto-viscoplástico que inclui dois procedimentos de análise: a resposta instantânea da estrutura considera um comportamento elastoplástico e a resposta diferida da estrutura assume um comportamento viscoelástico. A modelagem das lajes é feita a partir da ideia de elementos reforçados, assim, são utilizados elementos finitos de casca de ordem superior SHELL281 como elementos base de concreto. Enquanto que a armadura passiva é modelada com elementos de reforço REINF264, considerando-as como uma linha de material mais rígido com aderência perfeita no interior dos elementos de casca, ou seja, como armadura incorporada. Por sua vez, para modelar a armadura ativa não-aderente utiliza-se elementos finitos unidimensionais LINK180 que funcionam como armadura discreta, a condição de não-aderência é satisfeita pelo comando CP. Destaca-se que a não-linearidade geométrica é inerente nos elementos finitos utilizados e que os mesmos são compatíveis entre si e com a ferramenta de customização UPF. Para validar a eficiência do modelo computacional, comparam-se resultados numéricos com valores experimentais disponíveis na literatura. A comparação dos resultados mostra que os modelos representam corretamente o comportamento das lajes ensaiadas experimentalmente. O baixo custo computacional de tempo, a boa precisão dos resultados e as ferramentas de processamento do ANSYS tornam-no em uma alternativa eficiente. / The need for improvement of systems and materials of the construction industry resulted in the use of prestressing as an alternative to reinforce concrete structures. The technical and economic advantages found in the design of concrete structures caused that this system has been gaining preference against the conventional system of reinforced concrete. In this sense, this work aims to contribute developing a computational model in ANSYS software, version 16.0, through the customization tool UPF (User Performance Features), to the study of reinforced and, bonded or unbonded, prestressed concrete slabs. The computational model implementation, based on the finite element method, has emphasis on the physical materials nonlinearity with an elasto-viscoplastic model that includes two analysis procedures: the instantaneous response of the structure considers an elastoplastic behavior and the delayed response of the structure assumes a viscoelastic behavior. The slab models are based in reinforcement elements, thus higher order shell finite elements SHELL281 are used as base elements of concrete. The reinforcement is modeled with reinforcing elements REINF264, as a line of more rigid material with perfect bonding inside the concrete elements, it is, as incorporated reinforcement. On the other hand, the finite elements LINK180 that work as discrete reinforcement are used to simulate prestressing tendons, CP command satisfies the absence of non-adherence. It is noteworthy that the geometrical nonlinearity is inherent to the finite element used and that they are compatible between them and with the customization tool UPF. To validate the computational model efficiency, numerical results are compared with experimental values available in the literature. The results comparison shows that the models represent correctly the behavior of experimentally tested slabs. The low computational cost of time, the good precision of results and the ANSYS processing tools make it an efficient alternative.
137

Verificação experimental da largura colaborante em mesas de lajes nervuradas. / Experimental verification the cooperating width in flange waffle slabs.

Paulo José Barreto Teixeira 26 October 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um estudo experimental para determinação da largura colaborante em mesas de lajes nervuradas de concreto armado. Esta largura é definida comumente utilizando-se as recomendações contidas nas diversas normas e procedimentos já consagrados de estruturas de concreto armado. Visando a determinação da largura da mesa que efetivamente contribui na capacidade resistente da seção de lajes nervuradas, foram instrumentados e ensaiados modelos que buscaram reproduzir faixas de nervuras e painéis de laje. As faixas possuíam dimensões reais de duas nervuras principais, enquanto as lajes reproduziam painéis em escala reduzida (1:2). Em parte dos modelos, foram inseridos extensômetros de resistência elétrica nas armaduras e no concreto, além de transdutores para verificação das flechas. Foram calculadas as larguras a partir das curvas de tensões e flechas verificadas experimentalmente. Verificou-se, também, a influência da presença de tubulação embutida ao longo da mesa das faixas de laje. / This paper presents an experimental study to determine the cooperating width in flange waffle slabs of reinforced concrete. This width is usually established through the recommendations in the various rules and procedures already defined for reinforced concrete structures. In order to determine the width of the flange that effectively contributes to the ability of the resistant section slabs, models that sought to play tracks of panels and ribbed slab were tested and instrumented. The strips had two actual dimensions of main ribs, while the slab panels were reproduced on a reduced scale (1:2). In some of the models, electrical resistance strain gages were inserted in the reinforcement and in the concrete, and the arrows were checked by the transducers. The Widths were calculated from the curves of stress and the arrows were experimentally verified. The influence of a pipe embedded along the tracks of the flange slabs were also taken into consideration.
138

Verificação experimental da largura colaborante em mesas de lajes nervuradas. / Experimental verification the cooperating width in flange waffle slabs.

Paulo José Barreto Teixeira 26 October 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta um estudo experimental para determinação da largura colaborante em mesas de lajes nervuradas de concreto armado. Esta largura é definida comumente utilizando-se as recomendações contidas nas diversas normas e procedimentos já consagrados de estruturas de concreto armado. Visando a determinação da largura da mesa que efetivamente contribui na capacidade resistente da seção de lajes nervuradas, foram instrumentados e ensaiados modelos que buscaram reproduzir faixas de nervuras e painéis de laje. As faixas possuíam dimensões reais de duas nervuras principais, enquanto as lajes reproduziam painéis em escala reduzida (1:2). Em parte dos modelos, foram inseridos extensômetros de resistência elétrica nas armaduras e no concreto, além de transdutores para verificação das flechas. Foram calculadas as larguras a partir das curvas de tensões e flechas verificadas experimentalmente. Verificou-se, também, a influência da presença de tubulação embutida ao longo da mesa das faixas de laje. / This paper presents an experimental study to determine the cooperating width in flange waffle slabs of reinforced concrete. This width is usually established through the recommendations in the various rules and procedures already defined for reinforced concrete structures. In order to determine the width of the flange that effectively contributes to the ability of the resistant section slabs, models that sought to play tracks of panels and ribbed slab were tested and instrumented. The strips had two actual dimensions of main ribs, while the slab panels were reproduced on a reduced scale (1:2). In some of the models, electrical resistance strain gages were inserted in the reinforcement and in the concrete, and the arrows were checked by the transducers. The Widths were calculated from the curves of stress and the arrows were experimentally verified. The influence of a pipe embedded along the tracks of the flange slabs were also taken into consideration.
139

Análise da confiabilidade da ligação laje-pilar interno sob punção de acordo com a NBR-6118:2014 / Reliability analysis of the slab-column intersection under puching according to NBR 6118:2014

Silva, Gustavo Ribeiro da January 2017 (has links)
As demandas do mercado da construção civil têm exigido vãos cada vez maiores e ao mesmo tempo alturas cada vez menores das vigas. Isto tem levado muitos projetistas à adoção da solução do pavimento em laje lisa em concreto armado ou protendido. No entanto, a ausência das vigas torna possível a ruptura das lajes por puncionamento junto aos pilares. A norma NBR-6118:2014 prescreve as disposições para o projeto de lajes sob punção. O trabalho proposto teve como objetivo principal a análise da confiabilidade da ligação laje-pilar interno sob o efeito da punção em lajes que se apoiam diretamente sobre pilares de acordo com a NBR-6118:2014. Primeiramente, com o intuito de se entender melhor o fenômeno da punção, realizou-se uma breve revisão bibliográfica, identificando os principais parâmetros que influenciam na resistência da ligação, assim como os principais métodos de análise e trabalhos realizados na área. Em seguida, estudou-se o software de análise em elementos finitos ANSYS (Analysis Systems Incorporated), especificamente a ferramenta UPF (User Programmable Features), que foi utilizada para adoção de um modelo constitutivo para o concreto. Utilizando o software, foram modeladas lajes estudadas por outros autores, visando a validação do modelo numérico. Para o estudo da confiabilidade foi dimensionado um conjunto de lajes lisas seguindo as prescrições da NBR 6118:2014. A análise da confiabilidade foi realizada utilizando a ferramenta PDS (Probabilistic Design System), empregando o método de simulação numérica de Monte Carlo com amostragem por Latin Hypercube. Por fim, determinou-se o índice de confiabilidade em cada projeto e realizaram-se análises paramétricas com as variáveis adotadas no trabalho. Os resultados obtidos mostraram que as lajes lisas sem armadura de cisalhamento projetadas segundo a NBR 6118:2014 obtiveram, em sua maioria, índices de confiabilidade adequados. Porém, para as lajes lisas com armadura de cisalhamento, o índice de confiabilidade foi, em grande parte, menor que o índice de confiabilidade alvo adotado. / The demands of the construction market have required increasingly large spans while diminishing of the beam heights. This has led many designers to adopt the pavement solucion of reinforced or prestressed concrete flat slab. However, the absence of the beams makes it possible to slabs failure by punching shear. The Standard NBR-6118: 2014 prescribes the requirements for the design of slabs under punching. The aim of this work was to analyze the reliability of the internal slab-column intersection under punching in slabs supported directly on columns according to NBR-6118: 2014. Firstly, in order to better understand the punching phenomenon, a brief bibliographic review was carried out, identifying the main parameters that influence the connection strength, as well as the main methods of analysis and published in the area. Then, the finite element analysis software ANSYS (Analysis Systems Incorporated), specifically the UPF (User Programmable Features) tool, was used to adopt a concrete constitutive model. Using the software, slabs studied by other authors were modeled, aiming at the validation of the numerical model. For the reliability study, a set of flat slabs was designed following the requirements of NBR 6118: 2014. The reliability analysis was performed using the PDS (Probabilistic Design System) tool, using the Monte Carlo numerical simulation method with Latin Hypercube sampling. Finally, the reliability index was determined in each project and parametric analyzes were performed with the variables adopted in the study. The results from this study show that the flat slabs without shear reinforcement designed according to NBR Standarts obtained appropriate reliability index. However, for the flat slabs with shear reinforcement, the reliability index, in most cases, did not achieve the target reliability index.
140

Customização do software ANSYS para análise de lajes de concreto protendido pelo método dos elementos finitos / ANSYS software customization for analysis of prestressed concrete slabs by finite element method

Alarcon Ayala, Igor Carlos January 2017 (has links)
A necessidade por aprimorar sistemas e materiais na indústria da construção civil derivou no uso da protensão como uma alternativa de reforço para estruturas de concreto. As vantagens técnicas e econômicas encontradas no projeto e execução de estruturas de concreto fizeram com que este sistema venha ganhando preferência frente ao sistema convencional de concreto armado. Nesse contexto, este trabalho visa contribuir desenvolvendo um modelo computacional no software ANSYS, versão 16.0, por meio da ferramenta de customização UPF (User Performance Features), para o estudo de lajes de concreto armado e protendido, com ou sem aderência. A implementação do modelo computacional, baseado no método dos elementos finitos, tem ênfase na não-linearidade física dos materiais através de um modelo elasto-viscoplástico que inclui dois procedimentos de análise: a resposta instantânea da estrutura considera um comportamento elastoplástico e a resposta diferida da estrutura assume um comportamento viscoelástico. A modelagem das lajes é feita a partir da ideia de elementos reforçados, assim, são utilizados elementos finitos de casca de ordem superior SHELL281 como elementos base de concreto. Enquanto que a armadura passiva é modelada com elementos de reforço REINF264, considerando-as como uma linha de material mais rígido com aderência perfeita no interior dos elementos de casca, ou seja, como armadura incorporada. Por sua vez, para modelar a armadura ativa não-aderente utiliza-se elementos finitos unidimensionais LINK180 que funcionam como armadura discreta, a condição de não-aderência é satisfeita pelo comando CP. Destaca-se que a não-linearidade geométrica é inerente nos elementos finitos utilizados e que os mesmos são compatíveis entre si e com a ferramenta de customização UPF. Para validar a eficiência do modelo computacional, comparam-se resultados numéricos com valores experimentais disponíveis na literatura. A comparação dos resultados mostra que os modelos representam corretamente o comportamento das lajes ensaiadas experimentalmente. O baixo custo computacional de tempo, a boa precisão dos resultados e as ferramentas de processamento do ANSYS tornam-no em uma alternativa eficiente. / The need for improvement of systems and materials of the construction industry resulted in the use of prestressing as an alternative to reinforce concrete structures. The technical and economic advantages found in the design of concrete structures caused that this system has been gaining preference against the conventional system of reinforced concrete. In this sense, this work aims to contribute developing a computational model in ANSYS software, version 16.0, through the customization tool UPF (User Performance Features), to the study of reinforced and, bonded or unbonded, prestressed concrete slabs. The computational model implementation, based on the finite element method, has emphasis on the physical materials nonlinearity with an elasto-viscoplastic model that includes two analysis procedures: the instantaneous response of the structure considers an elastoplastic behavior and the delayed response of the structure assumes a viscoelastic behavior. The slab models are based in reinforcement elements, thus higher order shell finite elements SHELL281 are used as base elements of concrete. The reinforcement is modeled with reinforcing elements REINF264, as a line of more rigid material with perfect bonding inside the concrete elements, it is, as incorporated reinforcement. On the other hand, the finite elements LINK180 that work as discrete reinforcement are used to simulate prestressing tendons, CP command satisfies the absence of non-adherence. It is noteworthy that the geometrical nonlinearity is inherent to the finite element used and that they are compatible between them and with the customization tool UPF. To validate the computational model efficiency, numerical results are compared with experimental values available in the literature. The results comparison shows that the models represent correctly the behavior of experimentally tested slabs. The low computational cost of time, the good precision of results and the ANSYS processing tools make it an efficient alternative.

Page generated in 0.025 seconds