• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Diseño de Plantillas en el Software Autocad Civil 3D para trabajos Topograficos y Diseño de Carreteras según Normas Peruanas

Borja Torres, Manuel Augusto, Ramírez Vilchez, Milagritos Del Pilar January 2011 (has links)
The present thesis is based on the creation of templates for topographical works and roads, the development of these files with the extension dwt and xml, created under the Peruvian Regulations, are part of a tool that serves to improve the geometrical design of roads, as it is the AutoCAD Civil 3D. The design of templates in the software AutoCAD Civil 3D, improving the design of topographical works and roads, since in Perú does not exist this type of template to help the development of projects in civil engineering more easily and exactly. In this way, through the help of the software and the use of the Peruvian legislation, it can build roads of any classification in Perú. These templates also help the editing and configuration of grading and surfaces. Through their styles of grading can be controlled the visualization of the cut and fill slopes. In this way, will have a better presentation on the design, for example, a lixiviation pool or an oxidation lake. Within the archives of templates, are the templates of layout´s planes, which will help us in the elaboration of planes, also known as documents for construction, also helps us to obtain the approval of a customer, the adoption of the demands of the government, participate in bids and the registration of the conditions as if it were built. / La presente tesis se basa en la creación de plantillas para obras topográficas y viales, la elaboración de estos archivos con extensión dwt y xml, creados bajo la Normatividad Peruana, forman parte de una herramienta que sirve para mejorar el diseño geométrico de carreteras, como es el AutoCAD Civil 3D. El diseño de plantillas en el software AutoCAD Civil 3D, mejora el diseño en obras topográficas y viales, ya que en el Perú no existe este tipo de plantilla que ayuden a la elaboración de proyectos en ingeniería civil con mayor facilidad y exactitud. De esta manera, mediante la ayuda del software y el uso de la Normatividad Peruana, se pueden construir carreteras de cualquier clasificación en el Perú. Estas plantillas también favorecen en la edición y configuración del grading y superficies. Mediante sus estilos de explanación se pueden controlar la visualización de los taludes de corte y relleno. De esta manera se tendrá una mejor presentación al diseñar por ejemplo una poza de lixiviación o una laguna de oxidación. Dentro de los archivos de plantillas, se encuentran las plantillas de maquetación de planos, que nos ayuda en la elaboración de los juegos de planos, también conocidos como documentos para construcción, también nos ayuda en obtener la aprobación de un cliente, la aprobación de las exigencias del gobierno, participar en licitaciones y registro de las condiciones como si estuviera construido.
2

Análise tomográfica quantitativa linear de espessuras ósseas alveolares com vistas ao diagnóstico em ortodontia - Proposta de método / A quantitative linear tomographic analisys of the alveolar bone thicknesses and its implications to diagnosis in Orthodontics A method proposal

Silva, Siddhartha Uhrigshardt 01 June 2012 (has links)
O objetivo principal desta pesquisa foi justificar a proposta de utilização de um novo método tomográfico (cone beam) de avaliação das espessuras ósseas alveolares, maxilares e mandibulares, por meio de testes objetivos das Condições de Repetitividade e de Precisão Intermediária associadas à variação intra e interoperadores, e conforme a utilização de programa computacional independente (AutoCAD®) para a realização das medições, aplicadas à sequência do Procedimento Operacional Padrão (POP) definido para este experimento. A Fase I da pesquisa registrou os critérios de obtenção da qualidade final das imagens tomográficas definitivas, a partir de equipamento iCAT® (Imaging Sciences International, Hatfield, Pa), com parâmetros de aquisição de 120KVp, 37,7mA e 26,9s, e considerando FOV cilíndrico de 13cm e matriz de 512x512 pixels. A resolução do voxel foi de 0,25mm; A Fase II registrou os critérios exploratórios relativos às condições operacionais do software de visualização, registro (inspeção e identificação) e medição das grandezas selecionadas. A Fase III registrou a realização dos testes de repetitividade e de reprodutibilidade das medidas. Um total de 72 grandezas lineares foram previamente definidas e metodologicamente testadas em sua qualidade de inspeção, identificação e medição, a partir da avaliação de sete (7) operadores independentes, cinco dos quais eram especialistas e com Mestrado Acadêmico em Ortodontia pela FOUSP e, o outro, especialista em Radiologia Odontológica e Doutor em Diagnóstico Bucal (FOUSP). Os examinadores foram previamente instruídos, calibrados e treinados considerando os requerimentos necessários à execução dos testes propostos. O protocolo de pesquisa foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Odontologia da Universidade de São Paulo (Parecer CAAE 0120.0.017.000-11). A análise estatística dependeu da utilização de Modelo de Componentes de Variância (hierárquico), e foram consideradas como fontes de variação: as medidas, efetuadas por um mesmo operador ou por diferentes operadores; a face considerada, vestibular ou lingual/palatina; os locais (três níveis de espessura óssea alveolar) em cada uma das faces e, ainda, os diferentes dentes. Esta análise foi realizada de forma separada para mandíbula e maxila. Valores de p<0,05 indicaram significância estatística. Os resultados indicaram significativa confiabilidade geral no método proposto, considerando a Condição de Repetitividade, com apenas 0,24% da variabilidade maxilar total atribuível a um único operador, e mandibular de 0,53%; e com valores expressivos relativos às incertezas de medida maxilares (0,156mm) e mandibulares (0,091mm), desse modo atestando significativa consistência interna (repetibilidade) do método. Os testes da Condição de Precisão Intermediária também indicaram significativa confiabilidade geral no método proposto, com apenas 1,52% da variabilidade total mandibular atribuível à participação de diversos operadores, e maxilar de 0,25%; e com valores também expressivos relativos às incertezas de medida mandibulares (0,149mm) e maxilares (0,158mm), desse modo atestando significativa condição final de reprodutibilidade. Conclui-se que a utilização de imagens provenientes de tomógrafo iCAT®, conforme indicação de resolução de imagem com voxel de 0,25mm, em humanos vivos e a partir de cortes trans-axiais sistematicamente operacionalizados com auxílio de Software AutoCAD®, propicia a geração de condições metodológicas suficientemente favoráveis à obtenção de mapeamento quantitativo linear de espessuras ósseas alveolares, vestibulares e palatinas/linguais, tanto para a maxila quanto para a mandíbula. / This research aimed to justify the proposed use of a new tomography method (cone beam) in the clinical assessment of alveolar, maxillary and mandibular bone width, through objective tests of the Conditions of Repetitiveness and Intermediate Precision associated with intra- and inter-operator variation, using the independent computer program (AutoCAD®) for the execution of the measurements according to the Standard Operating Procedure (SOP) sequence defined for this experiment. Phase I of the research recorded the criteria for obtaining the final quality of the tomography images, using iCAT® (Imaging Sciences International, Hatfield, Pa, USA) equipment with acquisition parameters 120KVp, 37.7mA, and 26.9s, and considering cilindric field-of-view (FOV) of 13cm and 512x512 pixels matrix. The voxel resolution was 0.25mm. Phase II recorded the exploratory criteria relative to the operational conditions of the visualization software, registry (visual inspection and landmark identification) and measurement of the selected magnitudes. Phase III recorded the tests of repeatability and reproducibility of the measurements. A total of 72 linear magnitudes were previously defined and methodologically tested for their quality of inspection, identification and measurement, based on assessment by seven (7) independent operators, five of whom were specialists, with masters degrees in Orthodontics from FOUSP; and the other, a specialist in Dental Radiology and Doctor of Oral Diagnosis (FOUSP). The examiners were previously instructed, calibrated and trained according to the requirements for performing the proposed tests. The research protocol was approved by the Committee for Ethics in Research of the Faculty of Dentistry at the University of São Paulo (Protocol # 102/11-CAAE 0120.0.017.000-11). Statistical analysis used the (hierarchical) Components of Variation Model, and the sources of variation were considered to be: the measurements, made by the same operator or by different operators; the face considered, whether vestibular or lingual/palatal; the locations (three levels of alveolar bone thickness) in each of the faces and, also, the different teeth. This analysis was carried out separately for the mandible and the maxilla. Values of p<0.05 indicated statistical significance. The results indicated overall significant reliability in the proposed method considering the Condition of Repetitiveness, with only 0.24% of total maxillary, and 0.53% of mandibular, variability attributable to a single operator; and with expressive values relative to measurement uncertainties of maxillary (0.156 mm) and mandibular (0.091mm) averages, thereby attesting to significant internal consistency (\"repeatability\") of the method. Tests for the Condition of Intermediate Precision also indicated overall significant reliability of the proposed method, with only 1.52% total mandibular, and 0.25% maxillary, variability attributable to the participation of the various operators; and, also, with expressive values relative to measurement uncertainties of mandibular (0.149mm) and maxillary (0.158mm) averages, thereby attesting to the significant final condition of reproducibility. It is concluded that the use of images from iCAT® tomography, as indicated by image resolution with voxels of 0.25mm, in live humans and from transaxial cuts performed systematically with the help of AutoCAD® Software, provides methodological conditions sufficiently favorable for obtaining linear quantitative mapping of alveolar, vestibular and palatal/lingual bone thicknesses, for both the maxillary and mandibular dental arches.
3

Análise tomográfica quantitativa linear de espessuras ósseas alveolares com vistas ao diagnóstico em ortodontia - Proposta de método / A quantitative linear tomographic analisys of the alveolar bone thicknesses and its implications to diagnosis in Orthodontics A method proposal

Siddhartha Uhrigshardt Silva 01 June 2012 (has links)
O objetivo principal desta pesquisa foi justificar a proposta de utilização de um novo método tomográfico (cone beam) de avaliação das espessuras ósseas alveolares, maxilares e mandibulares, por meio de testes objetivos das Condições de Repetitividade e de Precisão Intermediária associadas à variação intra e interoperadores, e conforme a utilização de programa computacional independente (AutoCAD®) para a realização das medições, aplicadas à sequência do Procedimento Operacional Padrão (POP) definido para este experimento. A Fase I da pesquisa registrou os critérios de obtenção da qualidade final das imagens tomográficas definitivas, a partir de equipamento iCAT® (Imaging Sciences International, Hatfield, Pa), com parâmetros de aquisição de 120KVp, 37,7mA e 26,9s, e considerando FOV cilíndrico de 13cm e matriz de 512x512 pixels. A resolução do voxel foi de 0,25mm; A Fase II registrou os critérios exploratórios relativos às condições operacionais do software de visualização, registro (inspeção e identificação) e medição das grandezas selecionadas. A Fase III registrou a realização dos testes de repetitividade e de reprodutibilidade das medidas. Um total de 72 grandezas lineares foram previamente definidas e metodologicamente testadas em sua qualidade de inspeção, identificação e medição, a partir da avaliação de sete (7) operadores independentes, cinco dos quais eram especialistas e com Mestrado Acadêmico em Ortodontia pela FOUSP e, o outro, especialista em Radiologia Odontológica e Doutor em Diagnóstico Bucal (FOUSP). Os examinadores foram previamente instruídos, calibrados e treinados considerando os requerimentos necessários à execução dos testes propostos. O protocolo de pesquisa foi aprovado pelo Comitê de Ética em Pesquisa da Faculdade de Odontologia da Universidade de São Paulo (Parecer CAAE 0120.0.017.000-11). A análise estatística dependeu da utilização de Modelo de Componentes de Variância (hierárquico), e foram consideradas como fontes de variação: as medidas, efetuadas por um mesmo operador ou por diferentes operadores; a face considerada, vestibular ou lingual/palatina; os locais (três níveis de espessura óssea alveolar) em cada uma das faces e, ainda, os diferentes dentes. Esta análise foi realizada de forma separada para mandíbula e maxila. Valores de p<0,05 indicaram significância estatística. Os resultados indicaram significativa confiabilidade geral no método proposto, considerando a Condição de Repetitividade, com apenas 0,24% da variabilidade maxilar total atribuível a um único operador, e mandibular de 0,53%; e com valores expressivos relativos às incertezas de medida maxilares (0,156mm) e mandibulares (0,091mm), desse modo atestando significativa consistência interna (repetibilidade) do método. Os testes da Condição de Precisão Intermediária também indicaram significativa confiabilidade geral no método proposto, com apenas 1,52% da variabilidade total mandibular atribuível à participação de diversos operadores, e maxilar de 0,25%; e com valores também expressivos relativos às incertezas de medida mandibulares (0,149mm) e maxilares (0,158mm), desse modo atestando significativa condição final de reprodutibilidade. Conclui-se que a utilização de imagens provenientes de tomógrafo iCAT®, conforme indicação de resolução de imagem com voxel de 0,25mm, em humanos vivos e a partir de cortes trans-axiais sistematicamente operacionalizados com auxílio de Software AutoCAD®, propicia a geração de condições metodológicas suficientemente favoráveis à obtenção de mapeamento quantitativo linear de espessuras ósseas alveolares, vestibulares e palatinas/linguais, tanto para a maxila quanto para a mandíbula. / This research aimed to justify the proposed use of a new tomography method (cone beam) in the clinical assessment of alveolar, maxillary and mandibular bone width, through objective tests of the Conditions of Repetitiveness and Intermediate Precision associated with intra- and inter-operator variation, using the independent computer program (AutoCAD®) for the execution of the measurements according to the Standard Operating Procedure (SOP) sequence defined for this experiment. Phase I of the research recorded the criteria for obtaining the final quality of the tomography images, using iCAT® (Imaging Sciences International, Hatfield, Pa, USA) equipment with acquisition parameters 120KVp, 37.7mA, and 26.9s, and considering cilindric field-of-view (FOV) of 13cm and 512x512 pixels matrix. The voxel resolution was 0.25mm. Phase II recorded the exploratory criteria relative to the operational conditions of the visualization software, registry (visual inspection and landmark identification) and measurement of the selected magnitudes. Phase III recorded the tests of repeatability and reproducibility of the measurements. A total of 72 linear magnitudes were previously defined and methodologically tested for their quality of inspection, identification and measurement, based on assessment by seven (7) independent operators, five of whom were specialists, with masters degrees in Orthodontics from FOUSP; and the other, a specialist in Dental Radiology and Doctor of Oral Diagnosis (FOUSP). The examiners were previously instructed, calibrated and trained according to the requirements for performing the proposed tests. The research protocol was approved by the Committee for Ethics in Research of the Faculty of Dentistry at the University of São Paulo (Protocol # 102/11-CAAE 0120.0.017.000-11). Statistical analysis used the (hierarchical) Components of Variation Model, and the sources of variation were considered to be: the measurements, made by the same operator or by different operators; the face considered, whether vestibular or lingual/palatal; the locations (three levels of alveolar bone thickness) in each of the faces and, also, the different teeth. This analysis was carried out separately for the mandible and the maxilla. Values of p<0.05 indicated statistical significance. The results indicated overall significant reliability in the proposed method considering the Condition of Repetitiveness, with only 0.24% of total maxillary, and 0.53% of mandibular, variability attributable to a single operator; and with expressive values relative to measurement uncertainties of maxillary (0.156 mm) and mandibular (0.091mm) averages, thereby attesting to significant internal consistency (\"repeatability\") of the method. Tests for the Condition of Intermediate Precision also indicated overall significant reliability of the proposed method, with only 1.52% total mandibular, and 0.25% maxillary, variability attributable to the participation of the various operators; and, also, with expressive values relative to measurement uncertainties of mandibular (0.149mm) and maxillary (0.158mm) averages, thereby attesting to the significant final condition of reproducibility. It is concluded that the use of images from iCAT® tomography, as indicated by image resolution with voxels of 0.25mm, in live humans and from transaxial cuts performed systematically with the help of AutoCAD® Software, provides methodological conditions sufficiently favorable for obtaining linear quantitative mapping of alveolar, vestibular and palatal/lingual bone thicknesses, for both the maxillary and mandibular dental arches.
4

Budova občanské vybavenosti / Civic amenities building

Čaplová, Michaela January 2022 (has links)
The aim of my master ‘s thesis is to elaborate the project documentation of kindergarten as nearly zero – energy buildings. The project consists of three parts. The first part (main part) presents the civil engineering design of the building. Kindergarten is single storey-building. The vertical load-bearing structures are designed from lime-sand blocks (above - ground floor) and the hollow concrete blocks filled with C20/25. Horizontal load-bearing structures are designed from the prestressed Spiroll floor panels. The roof consists of a flat roof with extensive greenery. The second part presents technical equipment of buildings. The third part presents acoustic assesment outside Kindergarten. The building site contains also an outdoor playground. I am using AutoCad software for drawing and Deksoft to calculate Energy Performance Certificate. All structures comply with the regulations and valid standards.

Page generated in 0.0387 seconds