• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 13
  • 3
  • 1
  • Tagged with
  • 37
  • 24
  • 20
  • 19
  • 17
  • 15
  • 14
  • 14
  • 11
  • 9
  • 9
  • 9
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Single-well tracer push-pull method development for subsurface process characterization / Early-time tracer injection-flowback test for stimulated fracture characterization, numerical simulation uses and efficiency for flow and solute transport

Karmakar, Shyamal 15 June 2016 (has links)
No description available.
12

\"Otimização da extração, separação cromatográfica, identificação e quantificação de fármacos em fluidos biológicos\" / \"Optimization of the extraction, chromatographic separation, identification, and quantification of drugs in biological fluids\"

Fernandes, Christian 20 December 2006 (has links)
Este trabalho apresenta o desenvolvimento de diferentes métodos para a determinação de fluoxetina, norfluoxetina e bisfosfonatos, utilizando técnicas modernas de preparo de amostras. Dentre eles, um método simples e sensível, empregando microextração em fase sólida (SPME) e cromatografia líquida foi desenvolvido para a análise de fluoxetina e norfluoxetina em plasma. As condições de SPME foram otimizadas empregando planejamento fatorial. A extração foi realizada utilizando fibras com PDMS-DVB, e a etapa de dessorção foi realizada em uma nova interface homemade com sistema de aquecimento. Extração com sorção em barra de agitação (SBSE) com derivatização in-situ, combinada com dessorção com solventes ou dessorção térmica, acoplada à cromatografia gasosa e espectrometria de massas (GC-MS), foi também empregada para a determinação de fluoxetina em plasma. Avaliou-se a derivatização dos analitos in situ com cloroformato de etila, bem como os parâmetros tempo de extração, solvente e tempo de dessorção. A combinação de SBSE e LC-MS foi também avaliada. As amostras de plasma foram submetidas à precipitação de proteínas com ácido tricloroacético, extraídas com SBSE, e analizadas por LC-MS. Os métodos SPME-LC, SBSE-GC e SBSE-LC desenvolvidos foram completamente validados, demonstrando serem adequados para analisar fluoxetina em amostras de plasma. Métodos rápidos para a determinação de etidronato, clodronato, pamidronato e alendronato, baseados em cromatografia de troca iônica com detecção indireta no ultravioleta, foram também desenvolvidos. Os métodos são simples e demonstraram precisão, exatidão e especificidade. Além disso, os métodos validados empregam colunas de sílica, mais baratas e de mais disponibilidade do que as colunas poliméricas, frequentemente utilizadas em métodos descritos na literatura para o mesmo propósito. / This study describes different methods to analyze fluoxetine, norfluoxetine and bisphosphonates, employing modern sample preparation techniques. A simple and sensitive procedure using solid-phase microextraction (SPME) coupled with liquid chromatography was developed for the analysis of fluoxetine and norfluoxetine in plasma samples. SPME conditions were optimized employing a factorial design. The sampling step was performed using a PDMS-DVB fiber and desorption was carried out in a novel homemade heated interface. Stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry (GC-MS), was employed for the analysis of fluoxetine. In situ derivatization using ethylchloroformate was evaluated as well as parameters such as solvent polarity, time for analytes desorption, and extraction time. SBSE combined with liquid chromatography and mass spectrometry was also used to analyze fluoxetine in plasma. Plasma samples were first submitted to protein precipitation with trichloroacetic acid, subjected to SBSE, and thereafter analyzed by LC-MS. SPME-LC, SBSE-GC, and SBSE-LC methods were completely validated showing to be adequate to assess fluoxetine in plasma samples. Rapid methods for etidronate, clodronate, pamidronate and alendronate assay were also developed. The methods were based on ion chromatography with indirect ultraviolet detection, which avoids the need for chemical derivatization procedures. The methods were simple, rapid, and demonstrated precision, accuracy, and specificity. Furthermore, they employed silica-based columns, cheaper and more readily available than polymeric columns, frequently used in previous reported methods.
13

Strategies for improving kraftliner pulp properties

Antonsson, Stefan January 2008 (has links)
A large part of the world paper manufacturing consists of production of corrugated board components, kraftliner and fluting, that are used in many different types of corrugated boxes. Because these boxes are stored and transported, they are often subjected to changes in relative humidity. These changes together with mechanical loads will increase the deformation of the boxes compared to the case where the same loads are applied in a static environment. This enlarged creep due to the changes in relative humidity is called mechano-sorptive or accelerated creep. Mechano-sorptive creep forces producers to use high safety factors when designing boxes, and therefore, this is one of the key properties of kraftliner boards.   Different strategies to decrease mechano-sorptive creep, and to simultaneously gain more knowledge about the causes for this phenomenon in paper, are the aim of this work. Derivatised and underivatised black liquor lignins, a by-product produced in pulp mills in large quantities, have been used together with biomimetic methods, to modify the properties of kraftliner pulp. Furthermore, the properties of kraftliner pulp have been compared to other pulps in order to evaluate the influence of fibre morphological factors, such as fibre width and shape factor, on the mechano-sorptive creep. In addition the influence of the chemical composition of the kraftliner pulp has been evaluated both by means of treating a kraftliner pulp with chlorite and xylanase and by producing pulps with different chemical composition.   By using lignin and biomimetic methods, to create radical coupling reactions, it has been shown that it is possible to increase the wet strength of kraftliner pulp sheets. This method of treating the pulp showed, however, no significant effects on the mechano-sorptive creep. The addition of an apolar suberin-like lignin derivative, which has been shown to be possible to produce from natural resources, did show a positive effect on mechano-sorptive creep properties, but at the expense of stiffness properties in constant climate. Different pulps were compared with a kraftliner pulp and it was observed that the ratio between tensile stiffness and hygroexpansion can be used to estimate the mechano-sorptive creep properties. The hardwood kraft pulps investigated had lower hygroexpansion, probably due to more slender and straighter fibres, and higher tensile stiffness, probably due to lower lignin content. As the lignin content was varied by different methods in kraft pulps, it was observed that increased lignin content gives an increased hygroexpansion and decreased tensile stiffness as well as an increased mechano-sorptive creep. There were also indications of increased mechano-sorptive creep due to higher xylan content. / En stor del av världens papperstillverkning utgörs av produktion av wellpappkomponenter, kraftliner och fluting, som används i en uppsjö av olika wellpapplådor. När dessa lådor lagras och transporteras utsätts de ofta för förändringar i relativa luftfuktigheten. Dessa förändringar tillsammans med mekanisk belastning ökar lådornas deformation jämfört med om samma belastning skulle ha applicerats vid ett statiskt klimat. Denna förhöjda krypning på grund av förändringarna i relativ luftfuktighet kallas mekanosorptiv- eller accelererad krypning. Mekanosorptiv krypning tvingar producenterna att ha höga säkerhetsmarginaler vid dimensioneringar av lådor och är därför en av nyckelegenskaperna för kraftliner.   Olika strategier för att minska denna effekt, och på samma gång erövra mer kunskap om orsakerna till detta fenomen, har varit syftet med arbetet. Derivatiserade och oderivatiserade svartlutslignin, en biprodukt möjlig att få ut i stora kvantiteter från massabruk, har används tillsammans med biomimetriska metoder, för att modifiera kraftlinermassas egenskaper. Dessutom har kraftlinermassans egenskaper jämförts med andra massors egenskaper för att utvärdera inverkan av fibermorfologiska faktorer, såsom fiberbredd och fibreform på det mekanosorptiva krypet. Också inverkan av den kemiska sammansättningen av kraftliner massan har undersökts både genom behandling med klorit och xylanas och genom att producera massor med olika kemiska sammansättningar.   Genom att använda lignin och biomimetriska metoder för att skapa radikal-kopplingsreaktioner har det visats på möjligheten att öka våtstyrkan i massa-ark. Det här sättet att behandla massa visade dessvärre inga signifikanta effekter på det mekanosorptiva krypet. Tillsatts av ett apolärt suberin-liknande ligninderivat, som visats möjligt att producera ur naturliga råmaterial, visade en positiv effekt på det mekanosorptiva krypegenskaperna även om det var på bekostnad av styvheten vid konstant klimat. Olika massor jämfördes med en kraftlinermassa och det observerades att relationen mellan dragstyvhet och hygroexpansion kan användas för att uppskatta de mekanosorptiva krypegenskaperna. Lövvedssulfatmassorna som undersöktes hade lägre hygroexpansion, antagligen beroende på smalare och rakare fibrer, och högre dragstyvhet, troligen beroende på en lägre ligninhalt. När ligninhalten varierades i sulfatmassor med olika metoder observerades att ökad ligninhalt ger en ökad hygroexpansion och minskad dragstyvhet liksom en ökad mekanosorptiv krypning. Dessutom fanns indikationer på en ökad mekanosorptiv krypning till följd av högre xylaninnehåll. / QC 20100629
14

Étude du comportement des hydrocarbures aromatiques polycycliques (HAP) lors du déversement accidentel d'hydrocarbures en eaux continentales / Polycyclic aromatic hydrocarbons behavior study during accidental oil spill in continental waters

Pimsee, Pranudda 17 July 2014 (has links)
L’application de la Directive Cadre sur l’Eau et l’obligation de surveillance de la qualité de l'eau pour la consommation humaine et les activités industrielles entraînent une forte demande pour des systèmes d’évaluation et de suivi de la qualité de l’eau. Le projet de recherche MIGR'HYCAR (http://www.migrhycar.com) a donc été mis en place pour répondre à un besoin opérationnel et à un défaut d'outils d'aide à la décision adaptés face aux déversements d'hydrocarbures en eaux continentales (rivières, lacs et estuaires) qui représentent plus de 50% des déversements accidentels en France. Ce travail de thèse s'inscrit dans le cadre de ce projet et a pour but l’étude du comportement des nappes d'hydrocarbures en milieu contrôlé pour les eaux continentales. A cet effet, il propose une approche expérimentale à l’échelle laboratoire pour étudier les phénomènes agissant sur une nappe d'hydrocarbures déversée : dissolution, étalement, évaporation et volatilisation. Les données expérimentales réunis ont permis de constituer une base de données de référence, qui servira de support aux outils de modélisation mathématique de dérive de nappe d'hydrocarbures développés dans le cadre de ce projet. / The application of the European Water Framework Directive on water quality for human consumption and industrial activities creates a need for water quality assessment and monitoring systems. The MIGR'HYCAR research project (http://www.migrhycar.com) was initiated to provide decisional tools for risks connected to oil spills in continental waters (rivers, lakes and estuaries), which represent more than 50% of accidental spills in France. This work joins within the framework of this project and aims at the study of the behavior of hydrocarbons in a controlled environment for continental waters. For that purpose, the work proposes an experimental approach at laboratory scale to study the phenomena acting in oil spill: dissolution, spreading, evaporation and volatilization. The experimental data allowed establishing a reference database, which will serve as support in tools of oil spill modeling within the framework of this project.
15

Síntese de superabsorventes poliméricos biodegradáveis por meio da extrusão reativa do Poli (álcool vinílico) e amido, em presença de aldeído e ácido glioxílico, para uso agrícola / Superabsorbent synthesis of polymeric biodegradable through reactive extrusion of Poly (vinyl alcohol) and starch, in the presence of aldehyde and glyoxilic acid, for agricultural use

NASCIMENTO, CARLOS E. 21 December 2016 (has links)
Submitted by Marco Antonio Oliveira da Silva (maosilva@ipen.br) on 2016-12-21T18:14:50Z No. of bitstreams: 0 / Made available in DSpace on 2016-12-21T18:14:50Z (GMT). No. of bitstreams: 0 / Com a alta taxa de desertificação dos solos e a necessidade de irrigação constante dos plantios, existe a necessidade da criação de um polímero superabsorvente (SAP) com a característica de ser biodegradável. Observando o estágio tecnológico relacionado às atividades de pesquisa e desenvolvimento de SAPs no Brasil, foi utilizado o poli (álcool vinílico)/PVA e o amido de mandioca para a formação de hidrogéis a partir de blendas poliméricas. Assim, soluções aquosas desses polímeros foram reticuladas quimicamente, usando o glutaraldeído como agente reticulante e comparadas com amostras reticuladas por radiação gama, irradiadas a uma dose de 25 kgy. Os hidrogéis resultantes foram caracterizados por diversas técnicas analíticas como a fração gel, o intumescimento em água destilada, a espectroscopia de infravermelho com refletância total atenuada ATR (FT-IR), a termogravimetria (TG/DTG), a calorimetria exploratória diferencial (DSC) e a microscopia eletrônica de varredura (MEV). Observou-se uma maior reticulação nos hidrogéis reticulados com o glutaraldeído e em consequência um menor grau de intumescimento quando comparadas com as amostras que foram irradiadas. Com vias a produzir hidrogéis em uma escala industrial, misturas de PVA e amido foram processadas por extrusão reativa, mudando assim o processo de preparação de solução aquosa para misturas secas. Foram extrudadas amostras de PVA com diferentes pesos moleculares tais como o PVA 26-88, o PVA 40-88, o PVA 110-99 e o poli (ácido glioxílico vinílico)/PVGA, este último sintetizado a partir da modificação do PVA 110-99. Foi adicionado na mistura o ácido glioxílico no desenvolvimento do SAP por reticulação química nas amostras do PVA, por ter grupos carboxílicos que podem aumentar o intumescimento e também servir como agente reticulante. Também foram feitas formulações de extrusão sem o ácido glioxílico para serem usados como brancos. Adicionou-se nas misturas diversos agentes plastificantes como a glicerina e o polietilenoglicol (PEG 400) e as propriedades mecânicas foram estudadas. Foram desenvolvidas duas análises fatoriais de 23 para analisar as mudanças na reticulação das formulações. Os pellets foram caracterizados com as mesmas técnicas analíticas que os hidrogéis feitos em solução, adicionando-se análises de intumescimento e reversibilidade de intumescimento em diversos solventes como a água pura, a água da chuva, as soluções tampão de pH 3, pH 7 e pH 10, além de soro fisiológico, visando a aplicação em diferentes solos com diferentes pH e salinidades. Os testes de intumescimento em diferentes sais demonstraram a ter menor retenção de água quando comparada com água pura. Os testes de reversibilidade de intumescimento dos pellets mostraram que a maioria das formulações perde a sua capacidade de intumescimento máximo aos seis primeiros ciclos. Foi feita a compressão dos pellets para observar a flexibilidade dos mesmos, visando aplicações debaixo do solo. Realizou-se um estudo de biodegradação em terra ao longo de 120 dias, e estudou-se a relação direta com os valores da fração gel. Os resultados mostraram que os pellets menos reticulados intumesceram mais, enquanto as microscopias mostraram que essas amostras tinham uma morfologia mais porosa, o que contribuiu na melhora na retenção do líquido. Além disso, eram mais flexíveis e biodegradaram mais rápido, sendo extremamente viáveis para a aplicação na agricultura. Foi verificado que o PVA 40-88 apresentou os melhores valores de intumescimento em diferentes sais. Com o SAP obtido, foi constatado que a extrusão reativa é um método viável para a produção dos SAPs. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
16

\"Otimização da extração, separação cromatográfica, identificação e quantificação de fármacos em fluidos biológicos\" / \"Optimization of the extraction, chromatographic separation, identification, and quantification of drugs in biological fluids\"

Christian Fernandes 20 December 2006 (has links)
Este trabalho apresenta o desenvolvimento de diferentes métodos para a determinação de fluoxetina, norfluoxetina e bisfosfonatos, utilizando técnicas modernas de preparo de amostras. Dentre eles, um método simples e sensível, empregando microextração em fase sólida (SPME) e cromatografia líquida foi desenvolvido para a análise de fluoxetina e norfluoxetina em plasma. As condições de SPME foram otimizadas empregando planejamento fatorial. A extração foi realizada utilizando fibras com PDMS-DVB, e a etapa de dessorção foi realizada em uma nova interface homemade com sistema de aquecimento. Extração com sorção em barra de agitação (SBSE) com derivatização in-situ, combinada com dessorção com solventes ou dessorção térmica, acoplada à cromatografia gasosa e espectrometria de massas (GC-MS), foi também empregada para a determinação de fluoxetina em plasma. Avaliou-se a derivatização dos analitos in situ com cloroformato de etila, bem como os parâmetros tempo de extração, solvente e tempo de dessorção. A combinação de SBSE e LC-MS foi também avaliada. As amostras de plasma foram submetidas à precipitação de proteínas com ácido tricloroacético, extraídas com SBSE, e analizadas por LC-MS. Os métodos SPME-LC, SBSE-GC e SBSE-LC desenvolvidos foram completamente validados, demonstrando serem adequados para analisar fluoxetina em amostras de plasma. Métodos rápidos para a determinação de etidronato, clodronato, pamidronato e alendronato, baseados em cromatografia de troca iônica com detecção indireta no ultravioleta, foram também desenvolvidos. Os métodos são simples e demonstraram precisão, exatidão e especificidade. Além disso, os métodos validados empregam colunas de sílica, mais baratas e de mais disponibilidade do que as colunas poliméricas, frequentemente utilizadas em métodos descritos na literatura para o mesmo propósito. / This study describes different methods to analyze fluoxetine, norfluoxetine and bisphosphonates, employing modern sample preparation techniques. A simple and sensitive procedure using solid-phase microextraction (SPME) coupled with liquid chromatography was developed for the analysis of fluoxetine and norfluoxetine in plasma samples. SPME conditions were optimized employing a factorial design. The sampling step was performed using a PDMS-DVB fiber and desorption was carried out in a novel homemade heated interface. Stir bar sorptive extraction (SBSE) with in situ derivatization, in combination with either thermal or liquid desorption on-line coupled to gas chromatography-mass spectrometry (GC-MS), was employed for the analysis of fluoxetine. In situ derivatization using ethylchloroformate was evaluated as well as parameters such as solvent polarity, time for analytes desorption, and extraction time. SBSE combined with liquid chromatography and mass spectrometry was also used to analyze fluoxetine in plasma. Plasma samples were first submitted to protein precipitation with trichloroacetic acid, subjected to SBSE, and thereafter analyzed by LC-MS. SPME-LC, SBSE-GC, and SBSE-LC methods were completely validated showing to be adequate to assess fluoxetine in plasma samples. Rapid methods for etidronate, clodronate, pamidronate and alendronate assay were also developed. The methods were based on ion chromatography with indirect ultraviolet detection, which avoids the need for chemical derivatization procedures. The methods were simple, rapid, and demonstrated precision, accuracy, and specificity. Furthermore, they employed silica-based columns, cheaper and more readily available than polymeric columns, frequently used in previous reported methods.
17

Versatile silicone rubber samplers for trace organic analysis in a chromatography-mass spectrometry laboratory

Naude, Yvette 05 April 2013 (has links)
Extraction is required to separate and concentrate trace level analytes from the sample matrix prior to gas chromatography (GC). Classical extraction procedures utilise large amounts of hazardous solvents, generate waste, and sensitivity limitations are associated with the injection of microlitre amounts of the final solvent extract. In response to real world challenges, and to overcome the problems associated with solvent extraction, novel silicone rubber (polydimethylsiloxane (PDMS)) samplers were developed for solvent free enrichment of trace level analytes from indoor air, contaminated soil, desert soil, ultra high temperature (UHT) milk and Pinotage wine. Versatile PDMS samplers as a loop, a multichannel trap, or a denuder for trace environmental forensics, geochemical and aroma investigations are presented. A unique off-line multidimensional GC approach involving heart-cut gas chromatographic fraction collection is described, as is off-line olfactory assessment of recombined heart-cuts for synergistic odour effects. PDMS loop samplers were used for the extraction of DDT (1,1,1- trichloro-2,2-bis(p-chlorophenyl)ethane) and its associated environmental pollutants from soil samples. Miniature denuder samplers accomplished separate concentration of vapour phase and of particulate phase fractions of DDT and its associated environmental pollutants from indoor air, in a single step. Ratios of airborne p,p’-DDD/p,p’-DDT and of o,p’-DDT/p,p’-DDT are unusual and do not match the ideal certified ingredient composition required of commercial DDT. Results suggest that commercial DDT used for indoor residual spraying may have been compromised with regards to insecticidal efficacy, demonstrating the power of this new environmental forensics tool. Multichannel PDMS trap samplers were used in a unique heart-cut multidimensional GC approach for off-line enantiomeric separation of o,p’-DDT and o,p’-DDD in air and soil. This alternative multidimensional method is compared to the complementary technique of comprehensive two-dimensional gas chromatography with time-of-flight mass spectrometry detection (GCxGC-TOFMS). PDMS loop samplers were also employed for the solvent free extraction of hydrocarbons from desert soil to investigate, for the first time, a possible geochemical origin of the enigmatic fairy circles of Namibia. It is proposed that microseepages of natural gas and low volatility hydrocarbons are expressed at the surface as a geobotanical anomaly of barren circles and circles of altered vegetation. Multichannel PDMS trap samplers were utilised for sampling of the headspace of UHT milk and of Pinotage wine, and to study off-line, using a portable olfactometer, synergistic effects between recombined heart-cut aroma compounds. Olfactory results show that a synergistic combination of 2- heptanone and 2-nonanone was responsible for a pungent cheese-like odour in UHT milk, while a synergistic combination of furfural and 2-furanmethanol was responsible for a roast coffee bean-like odour in coffee style Pinotage wine. The small, low cost samplers are quick and easy to assemble and they fit commercial thermal desorber systems. The PDMS samplers are reusable. Solvent extraction of the sampling materials, extract clean-up and pre-concentration are not required. Thus, potential loss of analyte, introduction of contaminants and waste disposal are minimised. Solvent free thermal desorption permits transfer of the entire sample mass to the cooled injection system (CIS) inlet of a GC resulting in greater sensitivity when compared to injection of microlitre amounts of a solvent extract. This allowed for sampling of smaller sized soil samples, shorter air sampling times and lower air sampling flow rates when compared to solvent based methods. / Thesis (PhD)--University of Pretoria, 2013. / Chemistry / unrestricted
18

Desenvolvimento da fase extratora SPME de poli(pirrol) e avaliação das técnicas SPME/LC e SBSE/LC para análises de antidepressivos em amostras de plasma / Developmento of polypyrrole SPME extraction phase and evaluation of the SPME/LC and SBSE/LC techniques to antidepressants plasma samples analyses

Chaves, Andréa Rodrigues 27 June 2008 (has links)
A depressão em idosos é uma desordem persistente e recorrente, resultado do stress psicossocial ou efeito de doenças fisiológicas, que podem acarretar a desabilidade do indivíduo, aumento dos sintomas das doenças clínicas, na maior utilização dos serviços de saúde e altas taxas de suicídios.A monitorização terapêutica permite a ndividualização do regime de dosagem, assegurando a eficácia clínica e minimizando os efeitos adversos dos fármacos, prescritos na clínica. Os antidepressivos têm sido monitorados, pois, apresentam intervalos terapêuticos bem estabelecidos, ou seja, a maioria dos pacientes, que apresentam concentrações plasmáticas dentro deste intervalo fixo, tem as desordens psiquiátricas mantidas sob controle e efeitos adversos aceitáveis. Os antidepressivos tricíclicos (ADTs): imipramina, amitriptilina, nortriptilina e desipramina, embora eficazes e ainda muito utilizados, apresentam efeitos adversos, não desejáveis. Os antidepressivos, inibidores seletivos da recaptação de serotonina (SSRIs): citalopram, fluoxetina, paroxetina e sertralina, apresentam eficácia clínica comparável aos clássicos ADTs, mas destituídos dos efeitos adversos associados aos mesmos. Os métodos convencionais, empregados no tratamento de amostras biológicas, para análises de antidepressivos por técnicas cromatográficas, têm sido a extração líquido-líquido e extração em fase sólida. A microextração em fase sólida tem sido empregada em diferentes análises em fluidos biológicos, porém essa técnica apresenta certas limitações como, o número limitado de fases extratoras disponíveis no comércio que sejam adequadas para a análise de compostos não iônicos. A avaliação de novas fases extratoras, mais seletivas, estáveis e de baixo custo tem sido requerida para a análise de fármacos. O interesse no uso de poli(pirrol) (PPY), como fase extratora para SPME, está relacionado às diferentes interações dos fármacos (hidrofóbicas, -, com o grupo funcional polar, troca iônica, ácido-base) aos grupos multifuncionais deste polímero. Sua polimerização pode ser alcançada tanto por oxidação química, quanto por eletrodeposição em meio aquoso ou orgânico. O método eletroquímico apresenta algumas vantagens, tais como: o polímero ou mistura de polimeros podem ser revestidos diretamente em um metal, incorporação de diferentes grupos funcionais, entre outras, a polimerização pode ser eletroquimicamente controlada através da voltametria cíclica. Neste trabalho o poli(pirrol) (PPY) foi eletrodepositado em eletrodo de aço inox e empregado para a microextração em fase sólida dos antidepressivos: paroxetina, fluoxetina, mirtazapina, duloxetina, sertralina e citalopram. As variáveis da eletrodeposição, número de ciclos e contra-íon empregado no processo de eletrodeposição foram otimizadas. Assim como as variáveis SPME: tempo, temperatura, pH e volume de amostra, e tempo e solvente de dessorção; almejando maior sensibilidade para o método SPME-PPY/LC UV proposto. A extração sortiva em barra de agitação (SBSE), técnica recente de preparo de amostras, para a pré-concentração de compostos orgânicos presentes em amostras biológicas, baseia-se na extração estática, através do polímero polidimetilsiloxano (PDMS), no qual ocorre a dissolução (sorção) do analito. Neste trabalho, as técnicas SBSE e cromatografia líquida de alta eficiência com detecção UV (SBSE/LC UV) foram avaliadas para a análise simultânea de antidepressivos em amostras de plasma para fins de monitorização terapêutica. As condições cromatográficas de análise, assim como as variáveis SBSE de extração (tempo, temperatura, força iônica, pH da matriz) e tempo de dessorção, foram otimizadas, visando adequada sensibilidade analítica. A validação analítica foi realizada segundo normas da ANVISA, para ambos os métodos propostos, em diferentes concentrações plasmáticas, as quais contemplam o intervalo terapêutico. Segundo os parâmetros de validação avaliados, os métodos SBSE/LCUV e SPMEPPY/LCUV padronizados poderão ser empregados nas análises dos antidepressivos, para fins de monitorização terapêutica. / Depression in the elderly is a persistent and recurrent disorder resulting from psychosocial stress or physiological effect or disease. This condition can lead to disability, cognitive impairment, enhanced symptoms of medical illnesses, increased use of health care services and, increased of suicide rates. Therapeutic monitoring allows individualization of the dose regimen, ensuring clinical effectiveness and minimizing the adverse effects of drugs, prescribed at the clinic. Antidepressants have been monitored because they present well - established therapeutic intervals; in other words, most of the patients present plasmatic concentrations within this fixed range, so that their psychiatric disorders are kept under control and the adverse effects are acceptable. The tricyclic antidepressants (ADTs) imipramine, amitriptyline, nortryptiline, and desipramine, have adverse effects. The selective serotonin reuptake inhibitors (SSRIs) antidepressants citalopram, fluoxetine, paroxetine, and sertraline, are clinically effectiveness as the classic ADTs, but they do not lead to the adverse effects associated to the latter. The conventional methods employed in the treatment of biological samples for analysis of antidepressants by chromatographic techniques have been the liquid-liquid extraction (LLE) and solid phase extraction (SPE) techniques. Solid-phase microextraction (SPME) has been used in various analyses of biological fluids. However, this technique has limitations such as the small number of comemercially available extracting phases that are appropriate for the analysis of non-ionic compounds. Investigation of new extraction phases that are more selective and stable, as well as inexpensive, has been requested for drug analysis. The interest in the use of poly(pirrole) (PPY) as an extraction phase for SPME is related to the different interactions of the drugs (hydrophobic, - , with the polar functional group, ionic exchange and acid-base) with the multifunctional groups on this polymer. The PPY polymerization can be achieved by chemical oxidation or electropolymerization in aqueous solution or organic solvents. The electrochemical method has advantages such as, the polymer or a mixes of polymers can be directly deposited on a metal wire, different functional groups can be incorporated, polymerization can be electrochemically controlled by cyclic voltammetry. In this work poly(pyrrole) was electropolymerized on stainless steel electrodes and employed for the solid phase microextraction of the antidepressants paroxetine, fluoxetine, mirtazapine, duloxetine, sertraline, and citalopram. The electropolymerization variables, the number of cycles and counterion employed in the process were optimized, as well as the SPME variables, time, temperature, pH, sample volume, and desorption solvent; aiming at a better sensibility for the proposed method SPME-PPY/LC-UV. The stir bar sorptive extraction (SBSE), recently established technique for samples preparation, that targets the pre concentration of organic compounds present in biological samples. It is based on static extraction, through the polymeric polydimethylsiloxane (PDMS), where there is analyte dissolution (sorption). In this work, the SBSE technique and liquid chromatography with UV detector (SBSE/LC-UV) were evaluated for the simultaneous determination of antidepressants in plasma samples for therapeutic monitoring purposes. The cromatographic conditions, the SBSE extraction variables (time, temperature, ionic strength and matrix pH), and the dessorption time were optimized for appropriate analytical sensibility. The analytical validation was accomplished according to the norms of ANVISA for both of the proposed methods, in different plasmatic concentrations, which contemplate the therapeutic interval. According to the evaluated validation parameters, the standardized methods SBSE/LC-UV and SPME-PPY/LC-UV can be used in the analyses of antidepressants for therapeutic drug monitoring purposes.
19

Desenvolvimento e aplicação de uma nova fase para extração por sorção em barra de agitação (SBSE) / Development and application of a new phase for stir bar sorptive extraction (SBSE)

Barletta, Juliana Yamashita 17 December 2010 (has links)
Uma fase polimérica inédita de polidimetilsiloxano/carvão ativado (PDMS-ACB) é proposta como fase extratora para extração por sorção em barras de agitação (SBSE). A barra de PDMS-ACB foi desenvolvida no laboratório usando um molde de teflon simples, demonstrando estabilidade e resistência aos solventes orgânicos. Utilizando uma única barra de PDMS-ACB mais de 150 extrações foram realizadas sem qualquer dano. A barra de SBSE contém aproximadamente 100 µL de revestimento polimérico, 2,36 mm de diâmetro e 2,2 cm de comprimento. A barra PDMS-ACB foi aplicada na extração de seis pesticidas (ametrina, atrazina, bifentrina, carbofurano, metribuzim e tebutiurom), com propriedades predominantemente polares, comumente aplicados em plantações de cana-de-açúcar. A barra PDMS-ACB foi utilizada na determinação de pesticidas em garapa através de cromatografia gasosa hifenada à espectrometria de massa (GC-MS). O planejamento experimental foi empregado na etapa de otimização da extração SBSE, um planejamento fatorial fracionado avaliou a influência dos principais parâmetros envolvidos. Posteriormente, o planejamento composto central (CCD) com conformação estrela foi explorado para otimizar os fatores significativos na extração. Apenas 200 µL de acetato de etila foram utilizados como solvente na dessorção líquida (LD). Para os compostos avaliados, o método apresentou limite de quantificação (LOQ) no intervalo de 0,5 - 40 µg L-1, as recuperações variaram entre 0,18 - 49,50 % e a precisão intra-dia variou de 0,072 - 8,40 %. Concluída a etapa de validação, o método foi aplicado em amostras reais de garapa disponíveis comercialmente em São Carlos-SP. / A novel polydimethylsiloxane/activated carbon (PDMS-ACB) is proposed as new polymeric phases for stir bar sorptive extraction (SBSE). The PDMS-ACB was developed in lab using simple teflon\'s mold, demonstrating remarkable stability and resistance to organic solvents, over 150 extractions without any damage. SBSE bar contained 100 µL of polymeric coating, a diameter of 2.36 mm and a length of 2.2 cm. It was applied to the determination of pesticides (ametryn, atrazine, bifenthrin, carbofuran, metribuzine and tebuthiuron) having predominantly polar properties, applied in sugarcane crops. PDMS-ACB was employed in the determination of pesticides in sugarcane juice using gas chromatography coupled to mass spectrometry (GC-MS). Experimental design was employed in the optimization step, a fractional factorial evaluated the main parameters involved in the extraction procedure. Afterwards, central composite design (CCD) was exploited to optimize the significant factors on the extraction. About 200 µL of ethyl acetate were employed as solvent in the liquid desorption (LD). The method presented limit of quantification (LOQ) from 0.5 to 40 µg L-1, recoveries varied 0.18 - 49.50% and precision intra-day 0.072 - 8.40%. Hence, the method was applied to the analysis of real sugarcane juice samples commercially available in São Carlos-SP.
20

Desenvolvimento das barras imunosorventes de agitação e avaliação das técnicas extração sortiva em barra de agitação, microextração em sorvente empacotado e cromatografia líquida para análise de antidepressivos em amostras de plasma / Development of immunosorbent stir bars and evaluation of stir bar sorptive extraction, microextraction by packed sorbent and liquid chromatography for the analysis of antidepressants in plasma samples

Leandro, Fernanda Zampieri 15 December 2010 (has links)
Neste trabalho, os anticorpos policlonais e monoclonais anti-fluoxetina foram produzidos em coelhos e camundongos, respectivamente, por imunização com o conjugado fluoxetina-soroalbumina bovina. Os anticorpos obtidos foram caracterizados em função da especificidade contra o fármaco por ELISA (enzyme linked immunosorbent assay) e posteriormente, purificados por afinidade em coluna fluoxetina-agarose labmade. Os anticorpos purificados foram imobilizados covalentemente na superfície vítrea das barras SBSE (extração sortiva em barra de agitação) labmade. Após a derivatização das barras com 3-aminopropiltrietoxisilano, dois métodos distintos de acoplamento dos anticorpos às barras SBSE foram avaliados: ativação com glutaraldeído e succinilação seguida de ativação via éster N-hidroxisuccinimida (NHS). A funcionalização das barras SBSE foi comprovada através da imobilização de enzima peroxidase (HRP) em lugar do anticorpo e posterior ensaio enzimático com as barras. Várias barras SBSE com diferentes áreas (1,2; 2,4; e 4,0 cm2) foram preparadas, dentre as quais, as com maior área imunosorvente apresentaram maiores taxas de recuperação do fármaco. A avaliação da morfologia da superfície da barra SBSE imunosorvente foi realizada através de Microscopia Eletrônica de Varredura (MEV). As variáveis do processo SBSE de imunoafinidade foram otimizadas para estabelecer o equilíbrio de sorção antígeno-anticorpo em um menor tempo de análise e obtenção de limite de quantificação compatível com o intervalo terapêutico do fármaco. As capacidades adsortivas das barras imunosorventes foram de 1,2 e 8 microgramas por cm2 para anticorpos policlonais e monoclonais, respectivamente. Os imunosorventes desenvolvidos apresentaram reatividade-cruzada apenas com norfluoxetina (metabólito ativo de fluoxetina). As barras imunosorventes foram reutilizadas aproximadamente 30 vezes, sem perda significativa da eficiência das extrações. Baseados nos parâmetros de validação analítica avaliados, os métodos de SBSE/LC-FD de imunoafinidade desenvolvidos são adequados para a determinação de fluoxetina em amostras de plasma de pacientes em terapia com o fármaco, para fins de monitorização terapêutica. Por conseguinte, esses métodos foram aplicados com êxito para análises de amostras de plasma de pacientes idosos em terapia com Prozac®. Neste trabalho, o método MEPS (microextração em sorvente empacotado)/LC-UV também foi desenvolvido e validado para análise simultânea de sertralina, paroxetina, citalopram, fluoxetina e mirtazapina em amostras de plasma para fins de monitorização terapêutica. As variáveis do processo MEPS foram otimizadas (pH e volume da amostra, força iônica, volume dos ciclos aspirar-dispensar e condições de dessorção) para estabelecer o equilíbrio de sorção em menor tempo de análise e obter sensibilidade analítica adequada para a determinação dos antidepressivos no intervalo terapêutico. O método MEPS/LC-UV desenvolvido permitiu integração da dessorção dos analitos e injeção da amostra no sistema cromatográfico (LC-UV) em uma única etapa, usando a microsseringa de extração MEPS. A fase extratora MEPS, M1 (C8/SCX), foi reutilizada mais de 50 vezes com perda mínima da eficiência da extração, comprovando a robustez do material sorvente. Segundo os parâmetros de validação analítica avaliados, o método MEPS/LC-UV desenvolvido é adequado para a determinação de antidepressivos em amostras de plasma para fins de monitorização terapêutica. / In this work, polyclonal and monoclonal anti-fluoxetine antibodies were developed in rabbits and mice by immunization with fluoxetine-bovine albumin conjugate, respectively. The developed antibodies were characterized on the basis of the specificity against the drug by ELISA (enzyme linked immunosorbent assay) and, subsequently they were purified by labmade fluoxetine-agarose affinity column. The purified antibodies were covalently immobilized onto the glass surface of labmade SBSE (stir bar sorptive extraction) bars. After derivatization of the bars with 3-aminopropyltriethoxysilane, two distinct methods were evaluated for the antibodies coupling to the SBSE bars: activation with glutaraldehyde and succinylation activation via ester N-hydroxysuccinimide (NHS). The functionalization of SBSE bars was confirmed by the immobilization of peroxidase (HRP) instead of the antibody and, subsequent enzymatic assay with the bars. Several SBSE bars with different areas (1.2, 2.4, and 4.0 cm2) were prepared, among of them the largest immunosorbent area showed higher recovery rates of the drug. The evaluation of surface morphology of the SBSE immunosorbent bar was performed using scanning electron microscopy (SEM). The SBSE immunoaffinity variables were optimized to establish sorption equilibrium of antigen-antibody in a short time analysis and to obtain the limit of quantification compatible with the therapeutic range of the drug. The adsorptive capacities of the immunosorbent bars were 1.2 and 8 micrograms per cm2 for polyclonal and monoclonal antibodies, respectively. The developed immunosorbents showed cross-reactivity only with norfluoxetine (active metabolite of fluoxetine). The immunosorbent bars were reused approximately 30 times without significant loss of the extraction efficiency. Based on evaluated analytical validation parameters, the developed immunoaffinity SBSE/LC-FD methods are suitable for the determination of fluoxetine in plasma samples from patients on therapy with the antidepressant for therapeutic drug monitoring. Therefore, these methods were successfully applied for the analysis of plasma samples from elderly patients undergoing therapy with Prozac®. In this work, the method MEPS (microextraction by packed sorbent)/ LC-UV was also developed and validated for the simultaneous analysis of sertraline, paroxetine, citalopram, fluoxetine and mirtazapine in plasma samples for therapeutic drug monitoring. The MEPS process variables were optimized (pH, sample volume, ionic strength, draw-eject cycles volume and desorption conditions) to establish the sorption equilibrium in a short time analysis and to obtain adequate analytical sensitivity for determination of antidepressants within therapeutic range. The developed MEPS/LC-UV method allowed integration of the analytes desorption and sample injection in the chromatographic system (LC-UV) in a single step, using a MEPS extraction microsyringe. The MEPS extraction phase, M1 (C8/SCX) was reused over 50 times with minimum loss of extraction efficiency, proving the robustness of the sorbent material. According to the evaluated analytical validation parameters, the developed MEPS/LC-UV method is suitable for the determination of antidepressants in plasma samples for therapeutic drug monitoring.

Page generated in 0.4391 seconds