• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Rugosidade e potencial anticariogênico de diferentes materiais restauradores adesivos com ou sem flúor / Roughness and anticariogenic potential of differents adhesive restorative materials with or without fluoride

Oliveira Júnior, Carlos da Cunha, 1979- 03 March 2011 (has links)
Orientadores: Luís Roberto Marcondes Martins, Regina Maria Puppin Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T02:16:19Z (GMT). No. of bitstreams: 1 OliveiraJunior_CarlosdaCunha_M.pdf: 1147567 bytes, checksum: ddfbf68f2d9875bfd54560350ef18e6e (MD5) Previous issue date: 2011 / Resumo: O objetivo deste trabalho foi avaliar o efeito do acúmulo de placa na rugosidade e o da liberação de flúor de materiais restauradores na desmineralização do esmalte ao redor das restaurações. As hipóteses testadas foram que materiais liberadores de flúor promovem menor extensão da desmineralização da estrutura dental adjacente e os materiais com monômeros resinosos possuem menor rugosidade de superfície. Para este estudo in vitro, 40 blocos de esmalte dentais bovinos foram divididos aleatoriamente em 4 grupos, cada qual com 10 fragmentos dentais restaurados com diferentes materiais: cimento de ionômero de vidro modificado por resina (Vitremer), nanoparticulado (Ketac N100), cimento ionomérico convencional (Ketac Molar), compósito resinoso (Filtek Z250). Os blocos dentais foram submetidos a um modelo de desmineralização bacteriano. Em seguida, os blocos restaurados foram levados ao rugosímetro para avaliação da rugosidade a qual foi comparada com discos dos materiais testados, confeccionados como padrões de rugosidade, então, o teste de microdureza foi realizado para se obter a dureza Knoop da estrutura dentaria adjacente ao material restaurador com indentações nos pontos 50, 100 e 150 ?m de distância, nas profundidades de 10 a 120 ?m, considerando as medidas a partir de 100 ?m com valores similares ao do esmalte hígido e os valores foram convertidos em volume mineral pela fórmula de Featherstone (1983). Em seguida, foi feita a análise do conteúdo mineral da interface esmalte/restauração, após a ação dos ácidos bacterianos pela microanálise de raio-x. Os resultados mostraram que todos os grupos submetidos ao desafio cariogênico tiveram aumento significativo de rugosidade superficial. O grupo dos compósitos resinosos sofreu menor aumento significativo de rugosidade, seguida dos cimentos resinosos modificados por resina, o nanoparticulado e o convencional. Os valores de volume mineral no grupo da Z250 foi significativamente menor que os grupos com cimentos ionoméricos. A microanálise revelou conteúdo de cálcio significativamente maior nos grupos restaurados com cimentos ionoméricos. Isto permitiu concluir que os materiais com conteúdo resinoso possuem melhor polimento superficial e que o esmalte adjacente aos restauradores que liberam flúor sofreu menor desmineralização, além de apresentar maior conteúdo de cálcio / Abstract: The aim of this study was to evaluate the effect of plaque accumulation on roughness and fluoride release from dental materials on enamel demineralization around restorations. The hypothesis was that fluoride-releasing materials have lower extent of demineralization of adjacent tooth structure. For this in vitro study, 40 bovine dental enamel blocks were randomly divided into four groups, each with 10 dental fragments restored with different materials: resin-modified glass ionomer cement (Vitremer), nanoionomer (Ketac N100), conventional glass ionomer cement (Ketac Molar), resin composite (Filtek Z250). The dental blocks were subjected to a bacterial demineralization model. Then the restored blocks were taken to rugosimeter for evaluation of the roughness which was compared with discs of the tested materials, prepared as roughness patterns, then the microhardness test was performed to obtain the hardness of tooth structure adjacent to the restorative material with indentations at points 50, 100 and 150 ?m apart, at depths from 10 to 120 ?m, considering the measures from 100 ?m with values similar to sound enamel and the values were converted to mineral volume by the formula Featherstone (1983). Next step was to analyze the mineral content of enamel interface / restore, after the action of bacterial acid by x-ray microanalysis. The results showed that all groups submitted to cariogenic challenge significantly increased surface roughness. The group of composite resins has increased significantly lower roughness, followed by resin-modified resin cements, the nanoionomer and conventional. The values of mineral volume in the group of Z250 was significantly lower than groups with ionomer cements. The microanalysis showed calcium content significantly higher in groups restored with glass ionomer cements. It was concluded that materials with resin content have better polishing surface and the enamel adjacent to fluoride releasing restorative suffered less demineralization, as well as the higher calcium content / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
2

Investigating cell adhesion to controlled surface chemistry via self-assembly of binary composition alkylthiol monolayers, streptavidin immobilization, and cell receptor ligand attachment /

Nelson, Kjell Erik, January 2003 (has links)
Thesis (Ph. D.)--University of Washington, 2003. / Vita. Includes bibliographical references (leaves 177-181).
3

Cascas de árvores como biomonitores da poluição atmosférica de origem veicular em parques urbanos da cidade de São Paulo / Tree barks as biomonitors of traffic related air pollution in urban parks of the city of São Paulo

Martins, Ana Paula Garcia 09 November 2009 (has links)
O presente estudo foi desenvolvido para caracterizar a área de influência dos corredores de tráfego, através do monitoramento da concentração de elementos-traço em cascas de árvores. Amostras (n = 98) de cascas de árvores de diversas espécies foram coletadas em cinco parques urbanos da cidade de São Paulo. Para controle, foram coletadas cascas de árvores numa zona rural de Embu-Guaçu, longe de tráfego ou de indústrias. As concentrações de Ba, Co, Cr, Cu, Fe, Ca, Pb, S e Zn foram determinadas nas amostras de cascas de árvores por espectrometria de fluorescência de raios-X. Amostras coletadas nos parques urbanos apresentaram níveis mais elevados de elementos-traço em comparação com as da região controle. Elementos relacionados a atividades antropogênicas exibiram maiores concentrações nas amostras coletads na periferia dos parques, diminuindo gradativamente para os seus centros. Áreas próximas a grandes avenidas ou próximas a semáforos e cruzamentos apresentaram maiores concentrações de elementos nas cascas. Em conclusão, o estudo mostrou que medidas de acúmulo de elementos traço em cascas de árvore, associadas a métodos geoestatísticos, podem auxiliar a determinação das zonas de maior influência da poluição veicular no cenário urbano / The present study was designed to characterize the area of influence of high traffic corridors by monitoring trace element concentrations on tree barks. Samples (n=98) of tree barks were collected from several tree species in five urban parks of the city of São Paulo. For controlling purposes, we collected tree barks in a rural area of Embu-Guaçu which is far from traffic or industries. Concentrations of Ba, Co, Cr, Cu, Fe, Ca, Pb, S and Zn were determined in these barks by X-ray fluorescence spectrometry. Samples from urban parks exhibited higher levels of trace elements in comparison with those from control region. Elements related to anthropogenic activities exhibited higher concentrations in tree barks at the periphery of the parks, decreasing when moving towards their centers. Areas facing the busy streets or those close to traffic lights or traffic junctions presented higher concentrations of elements in barks. In conclusion, the present study showed that measures of trace elements accumulation in tree barks within geostatistical methods can indicate areas of strong influence of vehicular pollution in the urban scene
4

Caracterização de filmes finos de nanopartículas de prata depositados por sputtering sobre resina epóxi

Andrade, José Elisandro de 08 August 2012 (has links)
In this work silver atoms were deposited by ion sputtering on the surface of two types of diglycidyl ether of bisphenol A (DGEBA) epoxy resin. The films of DGEBA and its precursors were characterized by Raman and infrared spectroscopy to identify the main functional groups and their relationship with the deposited silver atoms. Thermogravimetric (TG) and differential themogravimetric (DTG) analysis, and Raman spectroscopy was performed to study the thermal effects in the resin. Silver thin films of 5, 10, 15 and 20 nm were deposited on the epoxy resin at room temperature. Both the initial film of DGEBA and the subsequent silver thin film were analyzed by Atomic Force Microscopy (AFM) in non-contact mode. Silver thin films were also analyzed by x-ray diffraction (XRD) at room temperature. The AFM results showed the formation of silver crystallites on the surface of DGEBA at very low coverage whereas XRD indicated that most of them had their main axis aligned to the normal of the surface. Increase in the coverage led to an increase in the grain size as indicated by AFM. XRD results however indicated that the crystallite size remained almost constant while the appearance of peaks corresponding to other crystalline orientati ons suggests the coalescence of the original crystallites and an increase in size of the more dense planes, namely [111]. / Neste trabalho átomos de prata foram depositados por ion sputtering na superfície de dois tipos de resina epóxi diglicidil éter de bisfenol A (DGEBA). Os filmes de DGEBA e seus precursores foram caracterizados por espectroscopia Raman e infravermelha para identificas os principais grupos funcionais e suas relações com os átomos de prata depositados. Análises termogravimétrica (TG), termogravimétrica diferencial (DTG), e espectroscopia Raman foram realizadas para estudar os efeitos térmicos na resina. Filmes finos de prata de 5, 10, 15 e 20 nm foram depositados na resina epóxi a temperatura ambiente. Ambos filmes iniciais de DGEBA e o subsequente filme fino de prata foram analisados por Microscopia de Força Atômica (AFM) no modo de não contato. Os filmes finos de prata também foram analisados por difratometria de raios X (DRX) a temperatura ambiente. Os resultados de AFM mostram a formação de cristalitos de prata sobre a superfície da DGEBA para pequenas espessuras de recobrimento, enquanto DRX indica que a maioria dos cristalitos tem seu eixo principal alinhado normal à superfície. Um aumento na espessura de recobrimento leva a um aumento no tamanho do grão como indicado por AFM. Resultados de DRX porém, mostram que o tamanho de cristalito permaneceu quase constante, enquanto o aparecimento de picos correspondentes a outras orientações cristalinas sugere a coalescência dos cristalitos originais e um aumento no tamanho dos planos mais densos, principalmente [111].
5

Cascas de árvores como biomonitores da poluição atmosférica de origem veicular em parques urbanos da cidade de São Paulo / Tree barks as biomonitors of traffic related air pollution in urban parks of the city of São Paulo

Ana Paula Garcia Martins 09 November 2009 (has links)
O presente estudo foi desenvolvido para caracterizar a área de influência dos corredores de tráfego, através do monitoramento da concentração de elementos-traço em cascas de árvores. Amostras (n = 98) de cascas de árvores de diversas espécies foram coletadas em cinco parques urbanos da cidade de São Paulo. Para controle, foram coletadas cascas de árvores numa zona rural de Embu-Guaçu, longe de tráfego ou de indústrias. As concentrações de Ba, Co, Cr, Cu, Fe, Ca, Pb, S e Zn foram determinadas nas amostras de cascas de árvores por espectrometria de fluorescência de raios-X. Amostras coletadas nos parques urbanos apresentaram níveis mais elevados de elementos-traço em comparação com as da região controle. Elementos relacionados a atividades antropogênicas exibiram maiores concentrações nas amostras coletads na periferia dos parques, diminuindo gradativamente para os seus centros. Áreas próximas a grandes avenidas ou próximas a semáforos e cruzamentos apresentaram maiores concentrações de elementos nas cascas. Em conclusão, o estudo mostrou que medidas de acúmulo de elementos traço em cascas de árvore, associadas a métodos geoestatísticos, podem auxiliar a determinação das zonas de maior influência da poluição veicular no cenário urbano / The present study was designed to characterize the area of influence of high traffic corridors by monitoring trace element concentrations on tree barks. Samples (n=98) of tree barks were collected from several tree species in five urban parks of the city of São Paulo. For controlling purposes, we collected tree barks in a rural area of Embu-Guaçu which is far from traffic or industries. Concentrations of Ba, Co, Cr, Cu, Fe, Ca, Pb, S and Zn were determined in these barks by X-ray fluorescence spectrometry. Samples from urban parks exhibited higher levels of trace elements in comparison with those from control region. Elements related to anthropogenic activities exhibited higher concentrations in tree barks at the periphery of the parks, decreasing when moving towards their centers. Areas facing the busy streets or those close to traffic lights or traffic junctions presented higher concentrations of elements in barks. In conclusion, the present study showed that measures of trace elements accumulation in tree barks within geostatistical methods can indicate areas of strong influence of vehicular pollution in the urban scene
6

Estudo mecânico e microestrutural em dois sistemas de fixação interna usados em osteotomia sagital mandibular / Mechanical and microstructural evaluation of two internal fixation systems used in mandibular sagittal split ramus osteotomy

Mendes, Marcelo Breno Meneses, 1984- 24 August 2018 (has links)
Orientador: Roger William Fernandes Moreira / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T03:19:50Z (GMT). No. of bitstreams: 1 Mendes_MarceloBrenoMeneses_D.pdf: 3820602 bytes, checksum: 7c13797c10676481e3ebfd0492c570a9 (MD5) Previous issue date: 2014 / Resumo: O objetivo deste estudo foi avaliar, através da análise de rugosidade superficial, microscopia eletrônica de varredura (MEV), análise de composição através de espectroscopia de raios-X e análise de resistência mecânica, dois diferentes sistemas de fixação interna usados em fixação de osteotomia sagital do ramo mandibular. Foram selecionadas cinco placas retas do sistema 2,0 mm com quatro furos e 20 parafusos de 6 mm de comprimento de dois sistemas de fixação interna, grupo I: Tóride (Tóride Indústria e Comércio Ltda. -Mogi Mirim, São Paulo -Brasil) e grupo II: Medartis (Medartis AG -Basel, Suíça). Para os testes mecânicos, foram selecionadas dez hemimandíbulas de poliuretano, dividindo-as igualmente entre os grupos I e II. Inicialmente, foi realizada análise de rugosidade superficial em todas as placas dos dois sistemas, e os dados foram submetidos à análise de variância e teste de Tukey (p>0,05) para a comparação entre as médias. Em seguida, as mesmas placas foram avaliadas no espectrômetro por meio de difração de raios-X e logo após foram analisadas no MEV. Por último, foi realizado o teste mecânico, no qual as hemimandíbulas de poliuretano foram fixadas e submetidas ao teste de carregamento (1mm/min). Os dados foram analisados quanto à carga de pico (em Newtons) e o deslocamento de pico (em mm) para todos os grupos estudados, e posteriormente submetidos ao teste t. Os grupos testados apresentaram vestígios superficiais dos processos de usinagem, principalmente nas margens dos elos. O grupo II apresentou revestimento com uma camada de nitreto de titânio. A análise da rugosidade revelou diferença entre as regiões de centro e margem da placa para o grupo I; diferente do grupo II, o qual apresentou valor de rugosidade menor e mais uniforme. O teste mecânico revelou que o grupo II apresentou maior carga de pico. Os dados demonstraram que há diferença microestrutural e mecânica entre os grupos testados. / Abstract: The aim of this study was to evaluate, through surface roughness analysis, scanning electron microscopy (SEM), composition analysis by X-ray spectroscopy and analysis of mechanical strength, two different systems used in internal fixation of mandibular sagittal split osteotomy fixation. Five straight 2.0 mm system plates with four holes and 20 screws 6 mm length of two internal fixation systems were selected, group I: Toride (Toride Indústria e Comércio Ltda -Mogi Mirim, São Paulo -Brazil.) and group II: Medartis (Medartis AG -Basel, Switzerland). For mechanical testing, ten polyurethane hemimandibles were used, distributing them equally into groups I and II. Initially, surface roughness analysis was performed on all plates of the two systems, and the data were subjected to analysis of variance and Tukey's test (p> 0.05) for comparison between means. Then, the same plates were evaluated in the spectrometer by means of X-ray diffraction and after this evaluation, they were subjected to SEM. Finally, mechanical testing was performed, in which the polyurethane mandibles were fixed and subjected to the load (1mm/min) test on an Instron testing machine, Model 4411 (Instron Corp., Norwood, MA). Data were analyzed for peak load (in Newtons) and peak displacement (in mm) for all groups, and then subjected to t test. The groups tested showed superficial traces of machining processes, especially on links periphery. Group II had coated with a layer of titanium nitride. The roughness analysis revealed differences among the regions of the center and edge of the plate for group I; group II showed roughness value smaller and more uniform, than group I.The mechanical test showed that group II had higher peak load. The data demonstrated that there are microstructural and mechanical differences between the tested groups. / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica

Page generated in 0.1128 seconds