• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • 25
  • 6
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 92
  • 23
  • 20
  • 10
  • 10
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Construção e validação de um túnel de vento para ensaios de estimativa da deriva em pulverizações agrícolas

Moreira Júnior, Orlando [UNESP] 09 October 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-10-09Bitstream added on 2014-06-13T20:22:35Z : No. of bitstreams: 1 moreirajunior_o_dr_botfca.pdf: 1169550 bytes, checksum: c39cff16dc4995bbd4495b150b625901 (MD5) / Este trabalho teve por objetivo a construção de um túnel de vento em escala reduzida e de baixo custo para utilização em estudos de tecnologia de aplicação de agrotóxicos, com posterior validação através da avaliação dos efeitos de diferentes adjuvantes pulverizados por uma ponta na intensidade do processo de deriva. Os ensaios foram conduzidos no Laboratório de Máquinas para Pulverização do Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA) da FCA/UNESP - Departamento de Engenharia Rural, localizado no campus da UNESP da cidade de Botucatu. O túnel de vento construído teve como principais características ser de circuito aberto e seção de teste fechada, com o sistema acionador (motor) abastecendo o circuito e agindo como soprador. Logo após o motor foram colocadas duas telas e uma colméia, com a finalidade de uniformizar o fluxo de ar que se desloca para a seção de testes onde são feitas as medidas. O túnel de vento foi confeccionado com chapas de fibras de eucalipto de espessura 3,0 mm e face superior lisa e face inferior corrugada, tendo comprimento total de 4,80 m, uma secção de testes quadrada de 56 cm x 56 cm e área útil de aproximadamente 0,31 m2 e 2,5 m de comprimento. Para o acionamento do túnel utilizou-se um ventilador de 5 velocidades e 180 W de potência. Todo sistema foi dimensionado para fornecer fluxo laminar de ar a uma velocidade de 2,0 m.s-1. Os ensaios de validação foram realizados com uma ponta de pulverização XR8003 (jato plano convencional de uso amplo) a uma pressão de 2 bar, produzindo um espectro de gotas médias, utilizada para aplicação de caldas (soluções em água) contendo o corante Azul Brilhante a 0,6% v/v em 9 mistura ou não com dois adjuvantes. Os primeiro adjuvante é um redutor de deriva a base de polímeros, utilizado na concentração... / The aim of this study was to build a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. Validation studies were undertaken by evaluating the effect of different adjuvants on the drift caused by the spray of a single nozzle. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The working section had 0.31 m2, with a total length of 2,5 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a XR 8003 flat fan nozzle at 2 bar (medium droplets) that was used to spray solutions containing water plus a food dye (Blue FDC) at 0,6% v/v mixed with the folowing adjuvants: a polymer based anti drift formulation at 0,06% m/v and a nonylphenol based surfactant at 0,2% v/v. After a 10-second application drift was collected on nylon strips transversally fixed along the tunnel at different distances from the 11 nozzle and different high from the bottom part of the tunnel. Drift deposits were avaluated by spectrophotometry at the NUPAM (Núcleo de Pesquisas Avançadas em Matologia), Departamento de Produção Vegetal/UNESP/FCA, Botucatu,SP, Brazil. The results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk under... (Complete abstract click electronic access below)
52

Construção e validação de um túnel de vento para ensaios de estimativa da deriva em pulverizações agrícolas /

Moreira Júnior, Orlando. January 2009 (has links)
Orientador: Ulisses Rocha Antuniassi / Banca: Wellington P.A. de Carvalho / Banca: Carlos Gilberto Raetano / Banca: Marco Antonio Gandolfo / Banca: Paulo Roberto Arbex Silva / Resumo: Este trabalho teve por objetivo a construção de um túnel de vento em escala reduzida e de baixo custo para utilização em estudos de tecnologia de aplicação de agrotóxicos, com posterior validação através da avaliação dos efeitos de diferentes adjuvantes pulverizados por uma ponta na intensidade do processo de deriva. Os ensaios foram conduzidos no Laboratório de Máquinas para Pulverização do Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA) da FCA/UNESP - Departamento de Engenharia Rural, localizado no campus da UNESP da cidade de Botucatu. O túnel de vento construído teve como principais características ser de circuito aberto e seção de teste fechada, com o sistema acionador (motor) abastecendo o circuito e agindo como soprador. Logo após o motor foram colocadas duas telas e uma colméia, com a finalidade de uniformizar o fluxo de ar que se desloca para a seção de testes onde são feitas as medidas. O túnel de vento foi confeccionado com chapas de fibras de eucalipto de espessura 3,0 mm e face superior lisa e face inferior corrugada, tendo comprimento total de 4,80 m, uma secção de testes quadrada de 56 cm x 56 cm e área útil de aproximadamente 0,31 m2 e 2,5 m de comprimento. Para o acionamento do túnel utilizou-se um ventilador de 5 velocidades e 180 W de potência. Todo sistema foi dimensionado para fornecer fluxo laminar de ar a uma velocidade de 2,0 m.s-1. Os ensaios de validação foram realizados com uma ponta de pulverização XR8003 (jato plano convencional de uso amplo) a uma pressão de 2 bar, produzindo um espectro de gotas médias, utilizada para aplicação de caldas (soluções em água) contendo o corante Azul Brilhante a 0,6% v/v em 9 mistura ou não com dois adjuvantes. Os primeiro adjuvante é um redutor de deriva a base de polímeros, utilizado na concentração... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to build a low cost reduced-scale wind tunnel for drift evaluation on pesticide application technology. Validation studies were undertaken by evaluating the effect of different adjuvants on the drift caused by the spray of a single nozzle. The work was carried out at the NEMPA - Núcleo de Ensaio de Máquinas e Pneus Agroflorestais (NEMPA), FCA/UNESP, Departamento de Engenharia Rural, Botucatu/SP, Brazil. The wind tunnel main characteristics were an open circuit and a closed working section with a fan blowing air into the tunnel. Screens were fitted downstream after the fan in order to stabilize the air flow on the working section. The tunnel was built with 3.0 mm eucalyptus hardboard, with a total length of 4.8 m and a squared section of 0.56 m. The working section had 0.31 m2, with a total length of 2,5 m. The air flow was provided by a 180 W axial fan. The system was adjusted and calibrated to provide a laminar and stable flow at 2.0 m s-1. Validation studies were carried out by using a XR 8003 flat fan nozzle at 2 bar (medium droplets) that was used to spray solutions containing water plus a food dye (Blue FDC) at 0,6% v/v mixed with the folowing adjuvants: a polymer based anti drift formulation at 0,06% m/v and a nonylphenol based surfactant at 0,2% v/v. After a 10-second application drift was collected on nylon strips transversally fixed along the tunnel at different distances from the 11 nozzle and different high from the bottom part of the tunnel. Drift deposits were avaluated by spectrophotometry at the NUPAM (Núcleo de Pesquisas Avançadas em Matologia), Departamento de Produção Vegetal/UNESP/FCA, Botucatu,SP, Brazil. The results showed that the tunnel was effective to enable comparative drift measurements on the spray solution used in this work making possible the evaluation of drift risk under... (Complete abstract click electronic access below) / Doutor
53

Desenvolvimento de um espectrofotômetro a laser de centro de cor aplicado ao estudo de cristais de NaF:Cu+:OH- / Development of a Color Center Laser spectrophotometer to study NaF:Cu+:OH- crystals

Jose Luis Fabris 10 March 1994 (has links)
Este trabalho se encontra dividido em duas partes. Em uma parte inicial, relatamos a construção e caracterização de um laser de centro de cor (LCC) com meio ativo de KCl:Li+, operando de forma sintonizável no infravermelho na região em torno de 2,7 um. São descritas três configurações distintas para a cavidade do laser, e fazemos um estudo comparativo do desempenho do LCC para os três casos. Na segunda parte, o laser de centro de cor foi transformado em um espectrofotômetro de duplo feixe de alta resolução (largura de linha OMEGA-V<O,2 cm-1), com o qual passamos a estudar amostras cristalinas de NaF multiplamente dopadas com impurezas moleculares OH- e monoatômicas Cu+. Relatamos novas características desse material, que surgem em virtude da interação entre as referidas impurezas. Dentre essas características, temos o surgimento de um espectro complexo de linhas deslocadas para menores energias com relação a banda de absorção do modo de estiramento do OH-. Parâmetros de anarmonicidade são analisados, os quais sugerem a existência de anarmonicidade elétrica em adição a anarmonicidade mecânica. Estudos da dependência das larguras das bandas de absorção com a temperatura juntamente com medidas de TSDC ( corrente de despolarização termo-estimulada), revelaram a existência de um comportamento diferente daquele de rotor quase livre encontrado para o OH- em vários halogenetos alcalinos. Os resultados mostraram que no cristal de NaF tanto o OH- isolado quanto o acoplado estão permanentemente orientados / This work has two parts. The starting one is related with the construction and characterization of a tunable color center laser (CCL) with an active medium of KCl:Li+ which works in the mid infrared region around 2,7 um. It is discussed three different configurations set up for the laser cavity, and the profile of each case is compared between each other. For the second part, the color center laser is used as the source of a high-resolution double beam spectrophotometer (line width OMEGA-V<O,2 cm-1). The spectrophotometer is used to study multiple doped NaF crystal samples, with OH- molecules and monoatomic Cu+ impurities. New optical properties are found due to assumed coupling interaction between both impurities, which gives rise to a more complex spectrum where several lines are displaced to lower energies relative to the main OH- stretching mode absorption. Some anharmonic effects are observed, which suggests the existence of electric anharmonicity added to the mechanical one. Further study of the bandwidth temperature dependence, together with thermally stimulated depolarization current measurements, reveal a different behavior of the usual OH- quasi-free rotor found in several alkali halides. The results show that for the NaF crystal the isolated and coupled OH- ions are permanently oriented
54

Construção e avaliação de um espectrofotometro infravermelho proximo (NIR) baseado em arranjo de sensores de PbS / Construction and evaluation of a near infrared (NIR) spectrophotometer based on a PbS sensor array

Giachero, Eduardo Alberto 12 April 2009 (has links)
Orientador: Celio Pasquini / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-15T04:25:20Z (GMT). No. of bitstreams: 1 Giachero_EduardoAlberto_M.pdf: 1521995 bytes, checksum: a202ae1d4c48dbb8607d5b36532d118a (MD5) Previous issue date: 2009 / Resumo: Este trabalho propõe o projeto e construção de um espectrofotômetro infravermelho próximo (NIR), compacto e de baixo custo, e a avaliação do seu desempenho na determinação de propriedades físico-químicas de combustíveis líquidos derivados do petróleo, visando a utilização do equipamento no controle dos processos de fabricação destes combustíveis. Na fase inicial do trabalho, foram investigados os tipos mais representativos de espectrofotômetros NIR utilizados atualmente pela indústria, analisando vantagens e desvantagens para auxiliar na definição dos componentes básicos do protótipo. Numa segunda etapa do projeto, foi executada a montagem de um protótipo baseado num detector de arranjo de sensores de PbS operando na faixa espectral de 2.100 a 2.500 nm, com a finalidade de determinar os parâmetros básicos do desempenho do equipamento (linearidade, repetibilidade, ruído e estabilidade do sinal). Numa terceira etapa foram introduzidas melhoras significativas no controle de temperatura do detector e optou-se pela mudança da faixa espectral de trabalho para 1600 a 2000 nm. Na última etapa foram construídos modelos PLS multivariados empregando-se espectros de 90 amostras de óleo diesel, visando a determinação de 5 parâmetros de qualidade deste combustível (índice de cetano e temperaturas de destilação de 10, 50, 85 e 90 % do volume do diesel). Os resultados obtidos foram comparados com os obtidos por um instrumento FT-NIR comercial, verificando-se desempenho equivalente. Os erros de estimação obtidos no protótipo (RMSECV) foram de 0,41 para o índice de cetano e de 3,1, 2,6, 3,4 e 4,0 °C para as temperaturas de destilação de 10, 50, 85 e 90 % do volume do diesel, respectivamente. Estes valores são inferiores ao erro de reprodutibilidade dos métodos analíticos de referência especificados pelas normas D86 e D4737 da ASTM. / Abstract: This work proposes the design and construction of a compact and low cost near infrared (NIR) spectrophotometer, and the evaluation of its performance in determination of physico-chemical properties of liquids fuels derived from petroleum with the aim of using the instrument in the process control of production of these fuels. In the initial step of this work, the more representatives NIR spectrophotometers used by the industry were investigated, analyzing their advantages and disadvantages to help in the definition of the basics components of the prototype. In a second step, a prototype was assembled using a PbS array detector, working in a spectral range from 2100 to 2500 nm to determine the basic parameters of system performance (linearity, repeatibility, signal noise, stability). In a third step, a critical improvement was made to better control the detector temperature. The spectral range was changed to 1600 ¿ 2000 nm, too. In the last step, PLS multivariate models were developed using the spectra set obtained for 90 samples of diesel with the objective of determine 5 quality parameters of this fuel (cetane index, distillation temperatures of 10, 50, 85 and 90% volume of diesel). The results were compared with those obtained by an FT-NIR commercial instrument, achieving equivalent performance. The estimated error obtained for the prototype (RMESV) were 0.41 to the cetane index and 3.1, 2.6, 3.4 and 4.0 for the distillation temperatures of 10, 50, 85 and 90% volume of diesel, respectively. These values are under the reproductibility error of the reference analytical methods especified by the D86 and D4737 ASTM standards. / Mestrado / Quimica Analitica / Mestre em Química
55

DETERMINAÇÃO DE GLICERINA LIVRE EM BIODIESEL UTILIZANDO MÉTODOS DE ANÁLISES ESPECTROFOTOMÉTRICO E CROMATOGRÁFICO/CG-DIC / DETERMINATION OF GLYCERIN IN BIODIESEL USING FREE METHODS OF ANALYSIS SPECTROPHOTOMETRIC AND CHROMATOGRAPHIC / GC-FID

Louzeiro, Hilton Costa 19 January 2007 (has links)
Made available in DSpace on 2016-08-19T12:56:32Z (GMT). No. of bitstreams: 1 HILTON COSTA LOUZEIRO.pdf: 594167 bytes, checksum: ac390253f4f716afae724d05120b3b91 (MD5) Previous issue date: 2007-01-19 / This work aim is to analyze the free glycerol content in biodiesel by means of gas chromatography and to establish a spectrophotometer method in the UV Visible region to attain it, as found in the literature. Biodiesel is the result product from the reaction between vegetable oils or animal fat (triglycerides) and alcohols (methanol or ethanol), producing esters fatty acids (biodiesel) and the glycerol as by-product. Even before the purification process, there are traces of free glycerol in the biodiesel. The ANP nº 42 / 2004 Resolution, establishes a maximum allowed limit of 0,02 % (200 mg/L) for free glycerol content per biodiesel mass (B100). The statistical analysis of data showed for the spectrophotometer method, a linear range of 100 to 500 mg/L, with correlation and determination coefficients of 0,9931 and 0,9863; respectively; a mean recovery index of 110,68 % for standard of 100 mg/L and 110,77 % for a standard of 200 mg/L, respectively; accuracy with variation coefficient of 7,94 % for a 200 mg/L standard and sensitivity with detection and quantification limits for the method corresponding to 5,69 mg/L and 18,11 mg/L, respectively. For the chromatographic method the linear range was 50 to 250 mg/L, with correlation and determination coefficients of 0,9964 and 0,9928, respectively; mean recovery index of 100,49 and 89,12 % for standard of 150 and 250 mg/L, respectively; accuracy with variation coefficient of 3,77 % for a 150 mg/L standard and sensitivity with detection and quantification limits for the method of 2,17 and 6,89 mg/L, respectively. Both analytical methods showed to be statistically sensitive and significant for the determination of free glycerin below the limits established by the ANP. However, the chromatographic method presented better adjustment results for the linear model, in agreement with the appraised parameters in the variance analysis. / O objetivo deste trabalho foi desenvolver um método para a análise do teor de glicerina livre em biodiesel por cromatografia a gás e validar um método por espectrofotometria na região do UV - Visível citado na literatura. O biodiesel é o produto resultante da reação entre óleos vegetais ou gordura animal (triglicerídeos) e álcoois (metanol ou etanol), produzindo ésteres de ácido graxo (biodiesel) e glicerina como subproduto. Mesmo depois do processo de purificação, existem traços de glicerina livre presentes no biodiesel. A Resolução ANP nº. 42 / 2004 propõe um limite máximo permitido de 0,02 % (200 mg/L) para o teor glicerina livre por massa de biodiesel (B100). A análise estatística dos dados mostrou para o método espectrofotométrico, uma faixa linear de 100 a 500 mg/L com coeficiente de correlação e coeficiente de determinação de 0,9931 e 0,9863, respectivamente; índice de recuperação médio de 110,68 % para um padrão de 100 mg/L e de 110,77 % para um padrão de 200 mg/L; uma precisão com coeficiente de variação de 7,94 % para um padrão de 200 mg/L e sensibilidade com limites de detecção e de quantificação do método de 5,69 mg/L e 18,11 mg/L, respectivamente. Para o método cromatográfico a faixa linear foi de 50 a 250 mg/L, com coeficiente de correlação e coeficiente de determinação de 0,9964 e 0,9928; índice de recuperação médio de 100,49 e 89,12 % para padrões de 150 e 250 mg/L, respectivamente; precisão com coeficiente de variação de 3,77 % para um padrão de 150 mg/L e sensibilidade com limites de detecção e de quantificação do método de 2,17 e 6,89 mg/L, respectivamente. Os dois métodos analíticos mostraram-se estatisticamente significativos e sensíveis para determinar concentrações de glicerina livre abaixo do limite estabelecido pela ANP. Entretanto, o método cromatográfico apresentou melhores resultados de ajuste ao modelo linear, de acordo com os parâmetros avaliados na análise de variância.
56

Alteração de cor e rugosidade superficial de resina composta clareada após envelhecimento em função do tempo / Color change and surface roughness of composite resin cleared after accelerated artificial aging as a function of time

Daniela de Biagi Freitas 30 July 2010 (has links)
O presente trabalho teve como objetivo analisar &ldquo;in vitro&rdquo; a alteração de cor e a rugosidade superficial de uma resina composta (Charisma®) submetidas a tratamento clareador com agente clareador Lase Peroxide Sensy® (CC) e grupo controle sem tratamento clareador (SCL), após envelhecimento (EAA) em função do tempo, realizando-se avaliação superficial complementar por meio de Microscopia Eletrônica de Varredura (MEV) e EDX. Os corpos-de-prova (n=15) foram confeccionados com o auxílio de uma matriz de Teflon nas dimensões de 11x2,0mm, polidos com discos Soft Lex®, na seqüência de abrasividade decrescente e armazenados em saliva artificial a 37ºC (±1ºC), até os momentos de serem submetidos aos tratamentos propostos e à realização das leituras de alteração de cor e rugosidade superficial, nos tempos: 24 horas após a confecção (T0), após envelhecimento artificial acelerado (T1), 24 horas após clareamento (T2), 7dias (T3) e 1 mês após clareamento (T4). As leituras de alteração de cor foram obtidas com o auxílio do aparelho Espectrofotômetro (PCB6807BYK GARDNER) e para as leituras de rugosidade superfícial foi utilizado o Rugosímetro Mitutoyo SJ201P. Os dados foram submetidos à Análise de Variância ANOVA (p&le;0,05). Os resultados obtidos foram: a) o fator Tempo teve efeito estatisticamente significante sobre as variáveis &Delta;E* (T1=T2=T3; T1=T4), L* (T0&lt;T1=T2=T3=T4), a* (T0&gt;T1=T2; T1=T3=T4; T4&gt;T2), b* (T0&gt;T1=T2=T3; T4=T3=T1; T2&lt;T4) e rugosidade superficial (&mu;m) (T0&lt;T1,T2,T3,T4; T1=T2; T1&lt;T3=T4; T2=T3=T4; b) para o fator tratamento com relação a &Delta;E* e fator L*(CC&gt;SCL), para os fatores a* e b*(CC&lt;SC), c) a interação Tratamento x Tempo não apresentou diferença estatisticamente significante para as variáveis &Delta;E*, L*, a*, b* e rugosidade superficial, d) as superfícies após EAA apresentaram alterações d) não houve mudanças no EDX antes e após os tratamentos. Conclui-se que a resina Charisma®, apresentou alteração de cor (&Delta;E*&gt;3,3) e uma estabilidade na rugosidade superficial a partir de T2. / The current study in vitro evaluated the color change and surface roughness of the composite resin Charisma® cleared with Lase Peroxide Sensy® (CCL) and control without bleaching (SCL) after accelerated artificial aging (EAA) as a function of time, performing additional surface evaluation by scanning electron microscopy (MEV) and EDX. To obtain the color change and surface roughness a Spectrophotometer (PCB 6807 BYK GARDNER) and rugosimeter (Mitutoyo SJ- 201P) were employed respectively. Measurements were carried out at five times: 24 hours after preparation (T0), after artificial accelerated aging (T1), 24 hours after bleaching (T2), 7days (T3) and 1 month after bleaching (T4). The specimens (n=15) were prepared with aid of a Teflon (10-mmin diameter and 2mm thick). The specimens were polished with discs Soft Lex®, following abrasiveness decreased, being stored in artificial saliva at 37ºC (±1ºC) until the time of undergoing the proposed treatments and the measurements. The data obtained were submitted to ANOVA parametric test (p &le; 0.05). The results were: a) time factor had a statistically significant effect on the variables &Delta;E* (T1 = T2 = T3, T1 = T4), L*(T0 &lt;T1 = T2 = T3 = T4), a* (T0 &gt; T1 = T2; T1=T3 =T4, T4&gt;T2), b* (T0&gt; T1=T2=T3, T4=T3=T1; T2&lt;T4) and roughness(&mu;m) (T0&lt;T1,T2, T3,T4; T1 = T2; T1&lt;T3=T4; T2=T3=T4), b) for treatment factor &Delta;E* and L* (CC&gt; SCL) for the factors a*and b* (CC &lt;SC), c) Treatment x Time interaction showed no statistically significant difference for the variables &Delta;E*, L*, a*, b* and surface roughness, d) after EAA the surfaces change d) before and after EAA dont have changes. It is concluded that the resin Charisma®, presented color change (&Delta;E *> 3.3) and surface roughness stability from T2.
57

An in-vitro study assessing the color stability of different provisional crown and bridge restorative materials

Barbara, Ndagire January 2006 (has links)
>Magister Scientiae - MSc / The aim of this study was to investigate the color stability of two provisional restorative materials used in crown and bridge cases upon exposure to different tea staining solutions and to evaluate the effectiveness of a polishing technique in removing the tea stains from the stained provisional restorative materials.
58

Comparación in vitro de la estabilidad cromática de tres resinas compuestas inmersas a sustancias amazónicas / In vitro comparison of the color stability of three composite resins immerse in Amazonian substances

Acosta Zuñiga, Mirtha Pamela, Pineda Prado, Alejandra Priscila 05 January 2020 (has links)
Objetivo: Comparar la estabilidad cromática de tres tipos de resinas (Te-econom Plus®- Ivoclar Vivadent, Tetric® N- Ceram Bulk Fill -Ivoclar Vivadent, Filtek™ Bulk Fill - 3M) inmersas a sustancias amazónicas Myrciaria dubia (camu camu) y Mauritia flexuosa (aguaje).  Materiales y métodos: Se evaluaron 180 discos de resina (6mm de diámetro y 4mm de altura) de cada marca: Te-econom Plus®, Tetric® N- Ceram Bulk Fill, Filtek™ Bulk Fill color A2 divididas en 9 grupos inmersas a sustancias amazónicas, Myrciaria dubia (Camu Camu), Mauritia flexuosa (Aguaje) y agua destilada (Grupo control) por 30 días. Los especímenes fueron inmersos en 20 ml de sustancias diariamente a temperatura de 37 C±5°. La evaluación del color se realizó a los 7, 15 y 30 días, utilizando un espectrofotómetro Vita Easyshade® Advance 4.0, para hallar los valores de ΔE. Los resultados fueron realizados mediante estadística descriptiva e inferencial. Para el análisis univariado, se utilizó las medidas de tendencia central (media) y en las medidas de dispersión (desviación estándar). Para el análisis bivariado, se utilizó la prueba de Kruskal Wallis para comparar los valores de la estabilidad cromática de las tres resinas compuestas. Resultados: La resina Tetric® N- Ceram Bulk Fill presentó menores valores de ΔE en Mauritia flexuosa (5.06 ±2.1) y la resina Filtek™ Bulk Fill presentó mayores valores de ΔE en Myrciaria dubia (11.42 ± 3.83) a los 30 días, a diferencia de la resina Te-econom Plus® que sí presentó cambios significativos en ambas sustancias y en todos los tiempos (6.79 ± 0.67), (16.63±5.29), (11.75 ±6.57).  Conclusión: La Myrciaria dubia (Camu Camu) es la sustancia amazónica que presentó mayor valor de ΔE en las tres resinas compuestas y en los tres tiempos de evaluación. La resina Filtek™ Bulk Fill presentó mayor estabilidad cromática. La resina Te-econom Plus® presentó menor estabilidad cromática en las sustancias de inmersión en los tres tiempos establecidos. / Objective: to compare the color stability of three types of resins (Te-econom Plus® - Ivoclar Vivadent, Tetric® N- Ceram Bulk Fill -Ivoclar Vivadent, Filtek ™ Bulk Fill - 3M) immersed in Amazonian substances Myrciaria dubia and Mauritia flexuosa. Materials and methods: 180 resin discs (6mm in diameter and 4mm in height) of each brand were evaluated: Te-econom Plus® - Ivoclar Vivadent, Tetric® N- Ceram Bulk Fill -Ivoclar Vivadent, Filtek ™ Bulk Fill - 3M, divided into 9 groups immersed in Amazonian substances, Myrciaria dubia, Mauritia flexuosa and distilled water (Control group) for 30 days. The specimens were immersed in 20 ml of substances daily at a temperature of 37 ° C ± 5 °. The color evaluation was performed at 7 days, 15 days and 30 days, using a Vita Easyshade® Advance 4.0 spectrophotometer, to find the ΔE values. The results were performed using descriptive and inferential statistics. For univariate analysis, measures of central tendency(mean) and dispersion measures (standard deviation) were used. For the bivariate analysis, the Kruskal Wallis test was used to compare the chromatic stability values of the three composite resins.  Results: The Tetric® N-Ceram Bulk Fill resin had lower ΔE values in Mauritia Flexuosa (5.06 ± 2.1) and Filtek ™ Bulk Fill resin had higher ΔE values ​​in Myrciaria dubia (11.42 ± 3.83) at 30 days, unlike Te-econom Plus® resin that did show significant changes in both substances and at all times (6.79 ± 0.67), (16.63 ± 5.29), (11.75 ± 6.57). Conclusions: The Myrciaria dubia (Camu Camu) is the Amazonian substance that presented the highest value of ΔE in the three composite resins and in the three evaluation times. Filtek ™ Bulk Fill resin showed greater color stability. The Te-econom Plus® resin showed lower chromatic stability in the immersion substances in the three established times. / Tesis
59

The Set-Up of a Foundation Colorant File for the Purpose of Color-Matching Foundations, With a View to Improving the Current Foundation Color-Matching Process in the Future / Utvecklandet av ett färg-referens-bibliotek med ändamålet att effektivisera kulörmatchning av foundations

Hedenström, Hanna January 2011 (has links)
The process of color-matching any color product is a process that can be quite complicated and requires great skill from a color analyst. As the name suggests color-matching is the process in which the color of a standard is obtained from a sample through careful inspection and precision in order for the colors to match up. It is a process that can vary in length dependent of the amount of pigments used.  Foundations are a type of liquid emulsion cosmetic and consist of five main pigments; white (titanium dioxide), red, brown, yellow and black iron oxides. These five pigments can when mixed together result in hundreds of shades. One of the greatest challenges for cosmetics companies is to successfully manufacture these shades often from a benchmark, a desired shade, as well as maintaining this same shade when the batch is scaled up from lab production to factory.  Oriflame is a direct-selling cosmetics company in which the Marketing department and Color Cosmetic department work closely in order to produce new products and shades for each catalogue. Liquid foundation shades are decided by the Marketing department and given to the Color Cosmetic department to color-match.  Currently the process of color-matching is carried out through the visual assessment by the color analyst. In order to improve the efficiency and lead - time of the current method, Oriflame has drawn inspiration from other sectors dealing with color and taken the decision to color-match with the use of a spectrophotometer coupled with color-appropriate software. The method was divided into four separate processes; confirming a sample method presentation to the spectrophotometer, colorant file set-up &amp; process, color-matching process with the color-appropriate software and color match comparison. The results showed that with an adequate sized colorant file a method for color-matching with a spectrophotometer was established. The lead-time could be decreased by, as much as 66.6 % and providing strong evidence that this is a valuable tool for color analysts working at Oriflame.
60

Study of Nitrogen Removal Rate and Trouble shooting of Pilot plant (ITEST).

Yatham, Venkata Krishna Reddy January 2012 (has links)
This paper is about improving the efficiency of nitrogen and other organic nutrient removal from activated sewage treatment by adopting an innovative technology. The work is to study the changes in nitrogen removal in pilot-scale experiments with the ITEST unit. The report also describes the various sources contributing to the eutrophication of the sea and water, caused by an increase in nutrient levels in different water bodies. Ineffective treatment of sewage contributes to the eutrophication. In the Baltic regions the temperature will be zero (0) or less than zero degree-centigrade during winter season. It results in decreased or fall in temperatures of incoming water to wastewater treatment plants. The temperature is an important parameter for sewage/wastewater treatment processes. Bacteriological nitrification and denitrification is an effective process for removing nitrogen from wastewater. From various research works and articles, it can be found that 23 + / - 2 °C, is the optimum temperature for nitrification and denitrification processes. So, the main aim is to study the effect of maintaining the incoming wastewater temperature by use of heat exchangers on incoming water to an activated sludge process line in pilot plant scale. In the pilot plant there were two testing lines; one line with heating system and the second line without heating system. A temperature of 19 to 20 °C was maintained in the influent to testing line. The nitrogen removal rates were compared between the two lines during the test period of approximately more than 8 months. Other biological activities in the treatment process were also compared between the two lines.

Page generated in 0.0651 seconds