1

Improving the therapeutic ratio of stereotactic radiosurgery and radiotherapy

Andisheh, Bahram January 2012 (has links)
New methods of high dose delivery, such as intensity modulated radiation therapy (IMRT), stereotactic radiation therapy (SRT) or stereotactic radiosurgery (SRS), hadron therapy, tomotherapy, etc., all make use of a few large fractions. To improve these treatments, there are three main directions: (i) improving physical dose distribution, (ii) optimizing radiosurgery dose-time scheme and (iii) modifying dose response of tumors or normal tissues. Different radiation modalities and systems have been developed to deliver the best possible physical dose to the target while keeping radiation to normal tissue minimum. Although applications of radiobiological findings to clinical practice are still at an early stage, many studies have shown that   sublethal radiation damage repair kinetics plays an important role in tissue response to radiation. The purpose of the present thesis is to show how the above-mentioned directions could be used to improve treatment outcomes with special interest in radiation modalities and dose-time scheme, as well as radiobiological modeling. Also for arteriovenous malformations (AVM), the possible impact of AVM network angiostructure in radiation response was studied. / Nya och förbättrade metoder för precisionsbestrålning, såsom intensitetsmodulerad strålbehandling (IMRT), stereotaktisk strålbehandling (SRT), stereotaktisk strålkirurgi (SRS) eller hadronterapi etc., gör det möjligt att leverera behandlingen i ett fåtal fraktioner med höga doser. Dessa behandlingmetoder kan ytterligare förbättras genom att (i) förbättra den fysikaliska dosfördelningen, (ii) optimera dosrater och fraktioneringsscheman eller (iii) modifiera dosresponsen hos tumörer eller normalvävnad. Olika strålmodaliteter och behandlingssystem har tagits fram för att kunna leverera bästa möjliga fysikaliska dosfördelning till targetvolymen samtidigt som dosen till frisk vävnad hålls så låg som möjligt. Även om användandet av radiobiologisk kunskap och modeller i klinisk rutin ännu är i sin linda så visar många studier att kinetiken för subletal reparation av strålskador har stor betydelse för strålresponsen. Syftet med denna avhandling är att visa hur dessa olika utvecklingsvägar kan användas för att förbättra behandlingsresultatet speciellt genom att studera vald strålmodalitet, dosrat och fraktioneringsschema samt radiobiologisk modellering. För arteriovenösa missbildningar (AVM) har även  studerats hur strukturen hos angionätverket påverkar strålresponsen. / <p>At the time of the doctoral defense, the following papers were unpublished and had a status as follows: Paper 3: Manuscript. Paper 4: Manuscript.</p>
2

STEREOTACTIC RADIOTHERAPY FOR SPINAL INTRADURAL METASTASES DEVELOPING WITHIN OR ADJACENT TO THE PREVIOUS IRRADIATION FIELD : REPORT OF THREE CASES

Tsugawa, Takahiko, Hagiwara, Masahiro, Nakazawa, Hisato, Kobayashi, Tatsuya, Shibamoto, Yuta, Hashizume, Chisa, Mori, Yoshimasa 08 1900 (has links)
No description available.
3

Hypofractionated conformal stereotactic radiotherapy in the treatment of AVMs and cerebral metastases

Lindvall, Peter January 2006 (has links)
Hypofractionated conformal stereotactic radiotherapy (HCSRT) has been used for the treatment of AVMs at the Umeå University Hospital since 1986. From this year and onwards an increasing number of patients with single or oligo brain metastases have also been treated using this technique. In paper I we have retrospectively evaluated our treatment results of AVMs in terms of obliteration and complications. The rates of obliteration and complications seem to be comparable with SRS even if the AVM volumes in our series were larger than in most series with SRS. In paper II we have retrospectively evaluated the results in terms of local control, survival and complications in two groups of patients with single or oligo brain metastases. One group was treated with HCSRT alone and the other group was treated with whole brain radiotherapy in combination with a stereotactic boost. Controversy still exists concerning the benefit of additional use of WBRT in combination with stereotactic irradiation. The survival times were equal in the two groups and no significant difference in local control was observed. The omission of WBRT seems to carry a higher risk for development new brain metastases distant from the irradiated area. In paper III we report the treatment results in a subgroup of AVMs treated with a combination of embolisation and HCSRT. We also focus on the reduction of vascular density within the nidus of an AVM and propose a method to digitally compare images and more objectively assess a reduction in vascular density following embolisation. Obliteration rates seem comparable with other series using a combination of SRS and embolisation even if our rate of complications was higher than what is usually reported. Using luminescence as measure of vascular density all AVMs seemed to be less dense after embolisation. Treatment accuracy in terms of reproducibility of the isocenter in consecutive treatment sessions is crucial in fractionated radiotherapy. In paper IV we have radiologically evaluated the reproducibility of the isocenter in successive treatment sessions using the non invasive relocatable Fixster frame. There was a high degree of reproducibility and only small errors that most likely is of no clinical importance. A reliable dose plan is equally important as a tool to predict the dose delivered inside and outside the target volume. In paper V we have evaluated the reliability of treatment plans in HCSRT for targets of different geometry and size. A liquid ion chamber and gel dosimeter was used for assessment of dose distribution and absorbed dose. The doseplanning system proved to be accurate in predicting the absorbed dose and dose distribution for the different targets.
4

Evaluation der intensitätsmodulierten Bestrahlungstechnik für die stereotaktische Strahlentherapie im kraniellen Bereich / Evaluation of stereotactic fractionated radiotherapy for the treatment of intracranial tumors

Hofmann, Tobias 13 February 2009 (has links) (PDF)
Die fraktionierte stereotaktisch geführte Radiotherapie stellt eine Möglichkeit der Behandlung intrakranieller Tumoren dar, bei denen eine chirurgische Resektion nicht oder nicht vollständig möglich ist. Ziel dieser Arbeit war der Vergleich der Dosisverteilung von Bestrahlungsplänen, die mittels fluenzmodulierter (IMRT) und 3D konformaler stereotaktisch geführter Bestrahlungstechnik (conformal beam) für Hypophysenadenome und petroclivale Meningeome erstellt wurden. Auf Basis des CT-Datensatzes eines Alderson-Phantoms erfolgten zunächst die systematische Untersuchung der IMRT Eingabeparameter und die Definition von Dosis-Volumen-Constraints für beide Tumorentitäten. Im Anschluss wurden die gewonnenen Erkenntnisse bei der fluenzmodulierten Bestrahlungsplanung von 10 realen Patienten, 5 je Tumorentität, angewendet. Zusätzlich wurde für jeden dieser Patienten ein 3D konformaler Bestrahlungsplan erstellt. Die Evaluation der Bestrahlungspläne erfolgte durch verschiedene quantitativer Parameter unter Einbeziehung der subjektiven Beurteilung der Dosisverteilung. Bei beiden Tumorentitäten lieferte in je 4 von 5 Fällen die IMRT einen Vorteil gegenüber der conformal beam Bestrahlung, der vor allem auf der besseren Erfassung, Dosishomogenität und höheren Median-Dosis im bestrahlten Zielvolumen (PTV) beruhte. Komplex geformte Zielvolumina profitierten dabei besonders von der Fluenzmodulation. Dem stand jedoch in einigen Fälle eine stärke Belastung der Risikoorgane (OAR) mit einer höheren Dosis und die generell höhere Anzahl notwendiger Monitoreinheiten gegenüber. Zuletzt wurde auf Basis von MatLAB eine Software entwickelt, welche die Verifikation von stereotaktisch geführten IMRT-Bestrahlungen und die Analyse von Winston-Lutz-Tests ermöglicht.
5

Evaluation der intensitätsmodulierten Bestrahlungstechnik für die stereotaktische Strahlentherapie im kraniellen Bereich

Hofmann, Tobias 13 February 2009 (has links)
Die fraktionierte stereotaktisch geführte Radiotherapie stellt eine Möglichkeit der Behandlung intrakranieller Tumoren dar, bei denen eine chirurgische Resektion nicht oder nicht vollständig möglich ist. Ziel dieser Arbeit war der Vergleich der Dosisverteilung von Bestrahlungsplänen, die mittels fluenzmodulierter (IMRT) und 3D konformaler stereotaktisch geführter Bestrahlungstechnik (conformal beam) für Hypophysenadenome und petroclivale Meningeome erstellt wurden. Auf Basis des CT-Datensatzes eines Alderson-Phantoms erfolgten zunächst die systematische Untersuchung der IMRT Eingabeparameter und die Definition von Dosis-Volumen-Constraints für beide Tumorentitäten. Im Anschluss wurden die gewonnenen Erkenntnisse bei der fluenzmodulierten Bestrahlungsplanung von 10 realen Patienten, 5 je Tumorentität, angewendet. Zusätzlich wurde für jeden dieser Patienten ein 3D konformaler Bestrahlungsplan erstellt. Die Evaluation der Bestrahlungspläne erfolgte durch verschiedene quantitativer Parameter unter Einbeziehung der subjektiven Beurteilung der Dosisverteilung. Bei beiden Tumorentitäten lieferte in je 4 von 5 Fällen die IMRT einen Vorteil gegenüber der conformal beam Bestrahlung, der vor allem auf der besseren Erfassung, Dosishomogenität und höheren Median-Dosis im bestrahlten Zielvolumen (PTV) beruhte. Komplex geformte Zielvolumina profitierten dabei besonders von der Fluenzmodulation. Dem stand jedoch in einigen Fälle eine stärke Belastung der Risikoorgane (OAR) mit einer höheren Dosis und die generell höhere Anzahl notwendiger Monitoreinheiten gegenüber. Zuletzt wurde auf Basis von MatLAB eine Software entwickelt, welche die Verifikation von stereotaktisch geführten IMRT-Bestrahlungen und die Analyse von Winston-Lutz-Tests ermöglicht.
6

Efficacy of salvage stereotactic radiotherapy for recurrent glioma: impact of tumor morphology and method of target delineation on local control / 再発神経膠腫に対する救済定位放射線治療 : 照射野設定と腫瘍形態の局所制御への影響

Ogura, Kengo 24 March 2014 (has links)
京都大学 / 0048 / 新制・課程博士 / 博士(医学) / 甲第18163号 / 医博第3883号 / 新制||医||1003(附属図書館) / 31021 / 京都大学大学院医学研究科医学専攻 / (主査)教授 福山 秀直, 教授 富樫 かおり, 教授 増永 慎一郎 / 学位規則第4条第1項該当 / Doctor of Medical Science / Kyoto University / DFAM
7

Study of peripheral dose in stereotactic radiotherapy with cyberknife with the use of the mobileMOSFET dose verification system / Μελέτη περιφερικής δόσης στη στερεοτακτική ακτινοθεραπεία με cyberknife με χρήση δοσιμετρικού συστήματος mobileMOSFET

Βλαχοπούλου, Βασιλική 26 April 2012 (has links)
The risk of secondary cancer associated with low doses of ionizing radiation, is gaining new interest every day, especially in long term surviving patients. The unavoidable amount of the scattered dose, which is absorbed by radiosensitive tissues/organs away from the irradiated treatment site, known as peripheral dose (PD), is the outcome of secondary irradiation sources while it influences the treatment parameters. Since the associated cancer risk is likely to be much lower but not insignificant from such low doses this may affect the choice of treatment options adopted. In this study, we performed measurements in a water phantom in order to indicate the trends of the PD from conventional radiotherapy and to demonstrate the influence of typical treatment parameters, such as the distance, the depth, the field size and the energy using the mobileMOSFET dose verification system. The PD is given as a function of the above treatment parameters and a comparison was made with an ionization chamber. In the same way measurements are presented in an anthropomorphic phantom and a comparison of the results between the mobileMOSFET dose verification system and the treatment planning software is given. Finally, the PD measurements were performed in preselected areas outside the treatment field in patients undergoing 3D conformal radiotherapy treatment and since, modern treatment modalities such as the stereotactic radiosurgery/radiotherapy (SRS/SRT) procedures consolidate more and more in the treatment of benign and malignant disease, we investigated the PD in patients undergoing intracranial and extracranial treatment with Cyberknife, before and after the shielding upgrade, and demonstrated the influence of the monitor units (MU) and the size of the collimator. A discussion for the potential of stochastic radiation induced effects with both treatment modalities is also given. Peripheral dose (PD) is strongly dependent upon the irradiation parameters selected during the treatment planning procedure such as the distance, the depth, the field size and the energy of the photon beam. More specifically, PD decreases almost exponentially with the increase of distance. Close to the edge of the field, the internal scattered radiation from the patient is the predominant source of secondary scattered dose. As the distance from the field edge increases, the radiation scattered by the collimator, and the machine leakage become predominant. On the other hand, the PD is higher near the surface and drops to a minimum at the depth of dmax, and then the PD tends to become constant with depth. Closer to the field edge, where internal scatter from the phantom dominates, the PD increases with depth, because the ratio of the scatter to primary increases with depth. A few centimetres away from the field, where collimator scatter and leakage dominate, the PD decreases with depth, due to the attenuation by the water. Finally, PD is significantly higher for larger field sizes, due to the increase of the scattering volume and as the energy increase the PD increases too. According the results of PD measurements with the 3D conformal radiotherapy treatment, the mean PD in the thyroid gland, expressed as a percentage of the prescribed dose (%TD), was 1.43 %, 9.85 %, 7.27% and 2.02 %, corresponding to whole brain irradiation, mediastinum treatment, and breast treatment with and without the irradiation of supraclavicular and axillary nodes, respectively. The risk of radiation induced cancer to the thyroid gland was estimated to be at levels of 0.18 %, 1.19 %, 1.18 % and 0.33 % respectively. The mean PD of the breast, expressed as a % TD, was 5.90 %, 2.59 % and 3.14% corresponding to mediastimun treatment and breast treatment with and without the irradiation of supraclavicular and axillary nodes, respectively. The risk to the breast was estimated to be at levels of 3.97 %, 1.76 % and 1.45%, in mediastinum and breast treatment, with and without the supraclavicular irradiation, respectively. Although the results indicate that there is not an increased risk of secondary cancer in the thyroid gland and the breast after conventional radiotherapy (3D CRT), the significance of this risk has to be considered taking into account the existing pathology and the age of the patient as also further studies are needed to determine the weight of each contributor to the peripheral dose as also. As a concern, the results of the PD measurements during Cyberknife treatment, the mean preshielding PD, as a percentage of the prescribed dose (% TD) was 2.32 %, 0.63 % and 0.48 %, in the thyroid gland, the umbilicus and the pubic symphysis, respectively, since in the preshielding measurements the nipple was not monitored. The mean postshielding PD was 2.06 %, 0.65 %, 0.59 %, and 0.47 %, in the thyroid gland, the nipple, the umbilicus and the pubic symphysis, respectively. The risk for inducing secondary cancers can be considered low for the organs studied, by taking into account the existing pathology of the patients undergoing Cyberknife treatment. However, it should not be completely disregarded, especially in long term surviving patients, who are being treated for benign diseases or for curatively non metastatic malignancies. We also concluded that the increase of the collimator size during Cyberknife treatment corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and the collimator scatter. Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure of Cyberknife in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases. The most important advantages of the mobileMOSFET dosimeter are its small size, as it can be easily placed on the patient’s skin and the almost direct estimation of the dose during exposure. Moreover, its sensitivity and reproducibility make it suitable for measurements of low PD, as it provides an adequate measure of dose at low dose levels for high-energy photon beam irradiations used for therapy applications. However, attention should be given to the utilized Calibration Factor (CF), since its sensitivity is affected by the accumulated dose during its lifetime. / Σύμφωνα με τη παγκόσμια έκθεση καρκίνου, περίπου 50% όλων των ασθενών με καρκίνο θα υποβληθούν σε ακτινοθεραπεία σε κάποια φάση της θεραπείας τους. Ο κίνδυνος εμφάνισης δευτερογενούς καρκίνου σε σχέση με τις χαμηλές δόσεις της ιοντίζουσας ακτινοβολίας μπορεί να είναι μικρός αλλά όχι αμελητέος, κερδίζοντας ένα ιδιαίτερο ενδιαφέρον στην επιστημονική κοινότητα της ακτινοθεραπείας, επηρεάζοντας τον τρόπο επιλογής των υιοθετημένων θεραπειών. Η σκεδαζόμενη δόση, που αναπόφευκτα απορροφάται από τα ακτινοευαίσθητα όργανα που κείτονται εκτός του όγκου/στόχου, αναφέρεται στην βιβλιογραφία ως περιφερική δόση. Η περιφερική δόση είναι αποτέλεσμα διαφόρων δευτερογενών πηγών ακτινοβολίας. Συγκεκριμένα, προέρχεται από τη σκεδαζόμενη ακτινοβολία εσωτερικά του ασθενούς, από τη διαρρέουσα και σκεδαζόμενη ακτινοβολία από τα μηχανικά μέρη που συνθέτουν το γραμμικό επιταχυντή όπως είναι ο πρωτεύον και δευτερεύον κατευθυντήρας, το φίλτρο επιπεδότητας, οι τροποποιητές δέσμης (σφήνες, μπλοκς, πολλαπλά φύλλα κατευθυντήρα), καθώς επίσης από τη σκεδαζόμενη ακτινοβολία από τους τοίχους, το ταβάνι και το πάτωμα του χώρου όπου στεγάζεται το ακτινοθεραπευτικό μηχάνημα αλλά και τη διαρρέουσα ακτινοβολία από τα δευτερογενή νετρόνια που παράγονται από τις φωτοπυρηνικές αλληλεπιδράσεις όταν η ενέργεια των φωτονίων είναι μεγαλύτερη των 10 MV. Όλο και περισσότερες μοντέρνες τεχνικές χρησιμοποιούνται στην ακτινοθεραπεία τόσο καλοήθη όσο και κακοήθη όγκων, όπως είναι η στερεοτακτική ακτινοχειρουργική και ακτινοθεραπεία, όπου υψηλή δόση δίδεται στον όγκο/στόχο ανά συνεδρία (υποκλασματοποίηση), διατηρώντας σε πολύ χαμηλά επίπεδα την δόση στους υγιείς ιστούς. Η εκτίμηση της περιφερικής δόσης με αυτές τις τεχνικές γίνεται ένα από τα σημαντικότερα δοσιμετρικά θέματα που απασχολούν την ακτινοθεραπευτική κοινότητα και κυρίως εστιάζεται σε ασθενείς νεαρής ηλικίας, σε ασθενείς με καλοήθη όγκο καθώς επίσης σε ασθενείς με μεγάλο χρόνο βιωσιμότητας. Συγκεκριμένα, αυτή η διδακτορική διατριβή είναι η πρώτη μελέτη που αναφέρεται σε μέτρηση της περιφερικής δόσης σε ασθενείς που υποβλήθηκαν σε ενδοκρανιακή και εξωκρανιακή στερεοταξία με το ρομποτικό σύστημα του Cyberknife. Επίσης είναι η πρώτη μελέτη όπου οι μετρήσεις της περιφερικής δόσης διεξήχθησαν με το δοσίμετρο MOSFET, χρησιμοποιώντας το δοσιμετρικό σύστημα mobileMOSFET. Τα σημαντικότερα πλεονεκτήματα του δοσιμέτρου MOSFET είναι το μικρό του μέγεθος, δεδομένου ότι μπορεί εύκολα να τοποθετηθεί στο δέρμα του ασθενούς, καθώς και η σχεδόν άμεση εκτίμηση της δόσης στα ακτινοευαίσθητα όργανα κατά τη διάρκεια της έκθεσης τους. Επιπλέον, η ευαισθησία και η επαναληψημότητά του, το καθιστούν κατάλληλο δοσίμετρο για τη μέτρηση χαμηλού επιπέδου δόσεων, όπου συγκαταλέγεται και η περιφερική δόση. Δεν απαιτούνται πολλοί παράγοντες διόρθωσης, ωστόσο, ιδιαίτερη προσοχή πρέπει να δοθεί στο συντελεστή βαθμονόμησης (CF), καθώς η ευαισθησία του, επηρεάζεται από τη συσσωρευμένη δόση κατά τη διάρκεια της ζωής του. Αρχικά πραγματοποιήθηκαν μετρήσεις σε ομοίωμα νερού, προκειμένου να αναδειχθεί η συμπεριφορά της περιφερικής δόσης με την επίδραση διαφόρων παραμέτρων της θεραπείας όπως είναι η απόσταση (από την άκρη του πεδίου) και το βάθος, καθώς και από το μέγεθος του πεδίου και την ενέργεια φωτονίων που χρησιμοποιήσαμε, κάνοντας στη συνέχεια σύγκριση των αποτελεσμάτων μας με το θάλαμο ιονισμού. Έγιναν μετρήσεις περιφερικής δόσης σε ανθρωπόμορφο ομοίωμα, για πέντε κλινικές περιπτώσεις (ολοκρανιακή ακτινοβόληση, ακτινοβόληση πνεύμονα, ακτινοβόληση μαστού με και χωρίς τους υπερκλείδιους και μασχαλιαίους αδένες, ακτινοβόληση του ορθού και του προστάτη) προκειμένου να εκτιμηθεί η πιθανότητα εμφάνισης δευτερογενούς καρκίνου στα μάτια, στο θυροειδή αδένα, τις ωοθήκες και τις γονάδες. Πραγματοποιήθηκε σύγκριση των μετρήσεων του δοσιμετρικού συστήματος mobileMOSFET με τους υπολογισμούς περιφερικής δόσης του συστήματος σχεδιασμού πλάνου ISIS 3D. Σε πενήντα (50) ασθενείς που προσήλθαν στο Πανεπιστημιακό νοσοκομείου του Ρίου, προκειμένου να υποβληθούν σε τρισδιάστατη σύμμορφη ακτινοθεραπεία, πραγματοποιήθηκαν μετρήσεις περιφερικής δόσης σε δυο ιδιαίτερα ακτινοευαίσθητα όργανα όπως είναι ο θυροειδής αδένας και ο μαστός, προκειμένου να εκτιμηθεί η πιθανότητα εμφάνισης δευτερογενούς καρκίνου σε αυτά, με βάση το μοντέλο που προτείνει η Διεθνής Επιτροπή Ακτινοπροστασίας (ICRP 103). Τέλος, πραγματοποιήθηκαν μετρήσεις της περιφερικής δόσης σε 35 ασθενείς που υποβλήθηκαν σε ενδοκρανιακή και εξωκρανιακή στερεοταξία με το ρομποτικό στερεοτακτικό σύστημα του Cyberknife είτε για καλοήθης (ακουστικό νευρίνωμα, μηνιγγίωμα, αδένωμα υποφύσεως κτλ.) είτε για κακοήθης ασθένειες (αρτηριοφλεβώδης δυσπλασία, οστικές και εγκεφαλικές μεταστάσεις, γλοιώματα κτλ.), προκειμένου να εκτιμηθεί η πιθανότητα εμφάνισης δευτερογενούς καρκίνου στο θυροειδή αδένα, το μαστό, και στα όργανα που βρίσκονται στην περιοχή του οφαλού και της ηβικής σύμφυσης. Επίσης μελετήθηκε η συμπεριφορά της περιφερικής δόσης με και χωρίς την αναβάθμιση της θωρακίσεως του ρομποτικού συστήματος, καθώς επίσης και με την επίδραση του αριθμού των monitor units και του μεγέθους του κατευθυντήρα. Σύμφωνα με τα αποτελέσματα των μετρήσεων στο ομοίωμα του νερού, η περιφερική δόση εξαρτάται από τις παραμέτρους ακτινοβόλησης όπως είναι η απόσταση από την άκρη του πεδίου και το βάθος, καθώς επίσης από το μέγεθος του πεδίου και την εκάστοτε ενέργεια των φωτονίων που χρησιμοποιήθηκε. Κοντά στην άκρη του πεδίου ακτινοβόλησης, η εσωτερική σκέδαση του ασθενούς είναι η κυρίαρχη πηγή δευτερογενούς ακτινοβολίας ενώ όσο απομακρυνόμαστε από το πεδίο η σκεδαζόμενη ακτινοβολία από τα διάφορα μέρη του ακτινοθεραπευτικού μηχανήματος καθώς και η διαρρέουσα ακτινοβολία είναι οι σημαντικότερες πηγές δευτερογενούς ακτινοβολίας. Η περιφερική δόση μειώνεται σχεδόν εκθετικά με την απόσταση. Συγκεκριμένα, η περιφερική δόση είναι μεγάλη κοντά στην επιφάνεια, εν συνεχεία μειώνεται μέχρι το βάθος της μέγιστης δόσης και στη συνέχεια παραμένει σχεδόν σταθερή. Η αύξηση του μεγέθους του ακτινοβολούμενου πεδίου συνεισφέρει σε μεγαλύτερη περιφερική δόση λόγω του μεγαλύτερου όγκου σκέδασης ενώ μεγαλύτερη περιφερική δόση έχουμε και με την αύξηση της ενέργειας των φωτονίων που χρησιμοποιούμε. Από τις μετρήσεις που έγιναν με ανθρωπόμορφο ομοίωμα, προκύπτει ότι το σύστημα σχεδιασμού θεραπείας ISIS 3D υπερεκτιμά την περιφερική δόση σε σημεία που είναι αρκετά μακριά από τον εκάστοτε όγκο στόχο. Σύμφωνα με τα αποτελέσματα του μετρήσεων στους ασθενούς που υποβλήθηκαν σε τρισδιάστατη σύμμορφη ακτινοθεραπεία, η μέση περιφερική δόση στο θυρεοειδή αδένα, ως ποσοστό της χορηγηθήσας δόσης, είναι 1.43 %, 9.85 %, 7.27 % και 2.02 %, στην ολοκρανιακή ακτινοβολία, στην ακτινοβόληση του μεσοθωρακίου και στην ακτινοβόληση του μαστού με και χωρίς την ακτινοβόληση των υπερκλειδίων και των μασχαλιαίων αδένων, αντίστοιχα. Η πιθανότητα εμφάνισης δευτερογενούς καρκίνου στο θυρεοειδή αδένα εκτιμήθηκε στα επίπεδα του 0.18 %, 1.19 %, 1.18 % και 0.33 % αντίστοιχα. Η μέση περιφερική δόση του μαστού μετρήθηκε αντίστοιχα 5.90 %, 2.59 % και 3.14 % για την ακτινοβόληση του μεσοθωρακείου και την ακτινοβόληση του μαστού με και χωρίς την ακτινοβόληση των υπερκλειδίων και μασχαλιαίους, αντίστοιχα. Η πιθανότητα εμφάνισης δευτερογενούς καρκίνου στο μαστό εκτιμήθηκε στα επίπεδα του 3.97 %, 1.76 % και 1.45 %, αντίστοιχα. Αν και τα αποτελέσματα δείχνουν ότι δεν υπάρχει ιδιαίτερα αυξημένος κίνδυνος εμφάνισης δευτερογενούς καρκίνου στο θυρεοειδή αδένα και το μαστό με την τρισδιάστατη σύμμορφη ακτινοθεραπεία, ιδιαίτερη έμφαση πρέπει να δοθεί στους ασθενείς που είναι νέοι ηλικιακά καθώς και σε αυτούς που έχουν μεγάλη επιβιωσιμότητα. Τα αποτελέσματα των μετρήσεων στους ασθενείς που υποβλήθηκαν σε ενδοκρανιακή στερεοταξία με το ρομποτικό σύστημα του Cyberknife, είναι τα ακόλουθα. Η μέση περιφερική δόση, ως ποσοστό της χορηγηθήσας δόσης, πριν την αναβάθμιση της θωρακίσεως του συστήματος, μετρήθηκε σε 2.32 %, 0.63 % και 0.48 %, στο θυρεοειδή αδένα, την περιοχή του ομφαλού και της ηβικής σύμφυσης, αντίστοιχα. Η μέση περιφερική δόση, μετά την αναβάθμιση της θωρακίσεως του συστήματος, μετρήθηκε σε 2.06 %, 0.65 %, 0.59 %, και 0.47 %, στο θυρεοειδή αδένα, το μαστό, την περιοχή του ομφαλού και της ηβικής σύμφυσης, αντίστοιχα. Η πιθανότητα εμφάνισης δευτερογενούς καρκίνου στο θυροειδή αδένα και στο μαστό, εκτιμήθηκε περίπου σε 0.12 % και 0.14 %, αντίστοιχα, μετά την αναβάθμιση θωρακίσεως του συστήματος Cyberknife. Γενικά η πιθανότητα δευτερογενούς καρκίνου και στα δύο όργανα υψηλού κινδύνου είναι μικρή αν αναλογιστούμε και την εκάστοτη παθολογία των ασθενών που υποβλήθηκαν σε ενδοκρανιακή στερεοταξία με το ρομποτικό σύστημα του Cyberknife. Ωστόσο δε θα πρέπει να αγνοηθεί για τους ασθενείς που είναι νέοι ή έχουν καλοήθη πάθηση ή μεγάλο χρόνο βιωσιμότητας. Στην περίπτωση του θυροειδούς αδένα, όπου κείτεται κοντά στην περιοχή ακτινοβόλησης, η πιθανότητα αυτή μπορεί να αυξηθεί δραματικά αν οι δέσμες εξόδου περάσουν μέσα από αυτόν. Επομένως, ένα ερώτημα που τίθεται είναι αν ο θυροειδής αδένας κατά το σχεδιασμό της θεραπείας πρέπει να θεωρηθεί ή όχι ως όργανο κινδύνου. Τέλος, καθώς επιβεβαιώθηκε ότι η περιφερική δόση είναι ανάλογη του αριθμού των monitor units, η εκτίμησή της μπορεί να γίνει έμμεσα από τα monitor units για δεδομένη απόσταση που βρίσκεται το εκάστοτε όργανο κινδύνου από τον όγκο στόχο. Παράλληλα συμπεράναμε ότι όσο αυξάνεται το μέγεθος του κατευθυντήρα η περιφερική δόση αυξάνεται. Είναι προφανές λοιπόν ότι η επίδραση αυτών των δυο παραμέτρων στη περιφερική δόση πρέπει να ληφθεί υπόψη κατά τη διάρκεια σχεδιασμού ενός πλάνου θεραπείας από τον ακτινοφυσικό, προκειμένου να κάνει τη βελτιστοποίησει του πλάνου θεραπείας, επιλέγοντας εκείνο που θα δώσει την μέγιστη δόση στον όγκο/ στόχο χωρίς να υπερβεί τα όρια δόσης ανοχής των υγιών ιστών.
8

La mesure et la modélisation des faisceaux de photons de petite taille pour l'IMRT et la radiochirurgie / Measurement and modeling of small fields photons beams for IMRT and radiosurgery

Abdul Hadi, Talal 24 May 2017 (has links)
Les nouvelles techniques de la radiothérapie (Stéréotaxie, IMRT, VMAT, IGRT...etc) utilisent des faisceaux de photons de très petite taille (mini-faisceaux) dans le cas de petite tumeur, au cerveau par exemple, afin d'irradier précisément la lésion. En effet, leur taille de champ est inférieure à 3cm×3cm à 100 cm de la source de rayonnement, cependant la mesure de la dose dans les mini-faisceaux est caractérisée par de forts gradients de dose et un manque d'équilibre électronique latéral, nécessitant l'utilisation de détecteurs ayant un volume sensible et une résolution spatiale adaptés, avec une équivalence-eau aussi bonne que possible afin d'améliorer la précision de la dose mesurée. Les détecteurs commercialisés ne remplissent parfaitement ces conditions. Actuellement, il n'existe pas de consensus méthodologique international, ni de référence métrologique pour mesurer la dose dans les mini-faisceaux. Le protocole IAEA 398 utilisé pour calculer la dose absorbée dans un faisceau de 10×10 cm², n'est plus approprié pour les mini-faisceaux. Ce travail compare la mesure des données dosimétriques par différents détecteurs conçus pour ce type de faisceau et optimise celui le plus proche de la réalité. En absconse de référence métrologique, la vérification de l'ensemble de la mesure des données dosimétriques est assurée par l'utilisation des films gafchromiques du fait de son excellente résolution spatiale. Cette étude propose une méthode expérimentale pour estimer la dose délivrée en stéréotaxie intracrânienne. Cette méthode est basée sur la mesure de la dose de fuite en un point situé en dehors du champ d'irradiation. / The advanced techniques of radiotherapy use very small fields in case small tumors such as in the brain to irradiate precisely the lesion. This work concerns the measurement absorbed dose in small field of 0.5×0.5cm² to 3×3cm². However, the measurement dose in small fields is characterized by high gradient dose and a leak of lateral electronic equilibrium. That requires use a detector having an adapted sensitive volume and adapted spatial resolution. The detectors marketed are not perfectly compatible with these conditions. Actually, there is no international methodological consensus, nor a metrological reference for measurement dose in small fields. The IAEA (International Atomic Energy Agency) protocol 398 used to calculate the absorbed dose at 10cm×10cm isn't suitable for small fields. In absence a referenced detector, the dosimetric data measurement is verified using a Gafcromic films due to its excellent spatial resolution. We measure using conventional detectors (ionization chambers and/or Gafcromic film) the leakage dose at a point outside of irradiated field. The dosimetric data such as output factor OF, depth PDD percentage depth dose and dose profile OAR were also carried out by the diode. The correlation between the on-axis dose and off-axis dose is the subject of our study. This study proposes an experimental method to calculate the on-axis dose in small field for stereotactic radiotherapy. The method is based on the out of field leakage measurement. This model can be used to validate dose and output factor measurement. The experimental validation of the present method was performed for square and rectangular fields with sizes ranging from 0.5cm×0.5cm to 10cm×10cm.
9

Développement d'un dosimètre diamant pour une mesure de la dose absorbée dans les mini-faisceaux utilisés en radiothérapie stéréotaxique. / Development of a diamond dosimeter for measuring the absorbed dose in small beams used in stereotactic radiotherapy

Marsolat, Fanny 10 January 2014 (has links)
La radiothérapie stéréotaxique est une technique de pointe relativement récente utilisée pour le traitement de tumeurs bénignes ou malignes de petites dimensions employant des mini-faisceaux. L'efficacité clinique de cette technique est prouvée et n'est pas remise en cause, cependant il n'existe pas actuellement de dosimètre véritablement approprié permettant de caractériser ces faisceaux de petites dimensions par des mesures précises de dose absolue et relative. Le problème du manque d'équilibre électronique latéral rencontré en mini-faisceaux entraîne principalement les contraintes suivantes pour le dosimètre : équivalence-eau et petit volume de détection. Les caractéristiques du diamant (faible numéro atomique Z=6, densité élevée d'atomes) en font un candidat idéal. Au cours de cette thèse, nous avons développé un prototype de dosimètre pour mini-faisceaux à partir de diamant monocristallin synthétique CVD. Les échantillons ont été caractérisés optiquement par différentes techniques et leurs propriétés de détection ont été étudiées sous rayonnement X et sous particules ?. Une série de premiers prototypes a été développée et testée sur plusieurs machines de stéréotaxie. Une étape d'optimisation de ces premiers dosimètres diamant a ensuite été réalisée notamment par l'utilisation de simulations Monte Carlo. L'optimisation des différents paramètres entrant en jeu dans la réponse du dosimètre en mini-faisceaux a permis d'aboutir à un prototype final de dosimètre diamant. Ce prototype répond au cahier des charges rédigé par les physiciens médicaux des centres hospitaliers, aussi bien en champs standards qu'en mini-faisceaux. / Stereotactic radiotherapy is a relatively recent technique used for the treatment of small benign and malignant tumors with small radiation beams. The clinical efficiency of this technique has been proved. However, the measurement of absolute and relative dose in small beams is not possible currently due to the lack of suited detectors for these measurements. In small beam dosimetry, the detector has to be as close as possible to tissue equivalence and exhibit a small detection volume due to the lack of lateral electronic equilibrium. Characteristics of diamond (water equivalent material Z=6, high density) make it an ideal candidate to fulfil most of small beam dosimetry requirements. In this thesis, we developed a dosimeter prototype for small beams, based on CVD synthetic single crystal diamond. The diamond samples were characterized optically and their detection properties were investigated under X-rays and alpha-particles. First diamond dosimeter prototypes were tested with small beams produced by several stereotactic machines. Studies using Monte Carlo simulations were performed in order to optimize the parameters involved in the detector response in small beams. This leaded to a final diamond dosimeter prototype that respects all radiotherapy centers requirements, in both standard and small beams.