• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 52
  • 51
  • 15
  • 7
  • 7
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 180
  • 180
  • 45
  • 43
  • 36
  • 30
  • 26
  • 19
  • 18
  • 18
  • 16
  • 14
  • 14
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Light scattering from characterised random rough surfaces

Kim, Min-Joong January 1989 (has links)
No description available.
32

Influência da utilização de nanopartículas de dióxido de silício ou polissiloxano acrilado nas propriedades físicas de materiais resinosos = Influence of silicon dioxide or acrylated polisiloxane on resin-based materials physical properties / Influence of silicon dioxide or acrylated polisiloxane on resin-based materials physical properties

Yanikian, Cristiane Rumi Fujiwara, 1982- 26 August 2018 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T19:03:50Z (GMT). No. of bitstreams: 1 Yanikian_CristianeRumiFujiwara_M.pdf: 6915738 bytes, checksum: 63867fbe5eef071b9c6effe63971fba8 (MD5) Previous issue date: 2015 / Resumo: A utilização de resinas compostas restauradoras cresceu consideravelmente nos últimos anos, porém, a alteração de cor associado à degradação da resina composta ainda é um importante fator para sua substituição. Portanto, o objetivo dos estudos foram de avaliar in vitro as propriedades físicas de diferentes selantes experimentais e os seus efeitos sobre a superfície de resinas compostas. No primeiro capítulo foram abordados os efeitos da utilização de cobertura de nanopartículas de dióxido de silício (SiO2) sobre diferentes resinas compostas. Os grupos experimentais foram divididos de acordo com os fatores resina composta (Filtek Z250XT, Filtek Z350XT e IPS Empress Direct) e a aplicação ou não de cobertura de SiO2 (n=8). Foram avaliados rugosidade superficial (Ra), energia livre de superfície (mJ/cm2), ângulo de contato formado pela água (?o) e alteração de cor (?E) após 24h de armazenamento em água destilada e após 15, 90 e 180 dias de armazenamento em vinho tinto. Os dados obtidos foram analisados por meio de Análise de Variância de Medidas Repetidas e teste de Tukey (?=0.05). O tempo de exposição ao vinho tinto influenciou negativamente em todas as variáveis, a aplicação da cobertura de SiO2 reduziu a energia livre de superfície, tornando as resinas mais hidrófobas. O aumento na rugosidade superficial foi observada a partir de 90 dias para todas as resinas compostas, independente do tratamento. Quanto a alteração de cor, a Filtek Z250XT e a IPS Empress Direct apresentaram menores valores de ?E quando comparadas à Filtek Z350XT. No segundo capítulo, os grupos estudados foram: PER - selante resinoso comercial (PermaSeal); STD - resina padrão manipulada (matriz monomérica Bis-EMA+TEGDMA carregada com 10% de partículas inorgânicas); SIL-resina padrão modificada por nanopartículas de SiO2 e; APS-resina padrão modificada por polissiloxano acrilado (n=10). Foram avaliados grau de conversão (%), sorção de água e solubilidade (µg/mm3) e módulo de elasticidade (GPa) em corpos de prova maciços confeccionados a partir dos selantes resinosos. Para os ensaios de ângulo de contato com a água (?o) e alteração de cor (?E), os selantes resinosos foram aplicados sobre a superfície de discos de resina composta (Filtek Z250XT) para então realizar a avaliação das amostras, um grupocontrole sem tratamento foi incluído nestes ensaios. O ?E foi calculado a partir de medidas obtidas antes e depois de 15 dias de imersão das amostras em vinho tinto. Os resultados foram analisados por meio de Análise de Variância de 1 critério e posterior teste de Tukey (?=0.05). A adição de nanopartículas de SiO2 promoveu menor solubilidade, adequado módulo de elasticidade e menor grau de alteração de cor e; a incorporação de polissiloxano acrilado promoveu melhor grau de conversão, menor sorção de água, apresentou maior hidrofobicidade e causou menor grau de alteração de cor quando comparadas aos controles. Portanto, a incorporação de aditivos hidrófobos não interferiu negativamente nas propriedades físicas dos selantes experimentais e foram efetivos para tornar resinas compostas mais hidrófobas e reduzir a sua alteração de cor / Abstract: The use of restorative composites has been increased in dental practice, however, the color change associated to composite surface degradation is still important issue for composite restorations replacement. Therefore, the aim of these studies were to in vitro evaluate physical properties of different experimental surface sealants and its effects on composite resins surfaces. In the first chapter, it has been evaluated the effects of the silicon dioxide nanoparticles (SiO2) coating on different composites. The experimental groups were divided according to the resin composite type (Filtek Z250XT, Filtek Z350XT and IPS Empress Direct) and application or not of SiO2 coating (n=8). Surface roughness (Ra), surface free energy (mJ/cm2), water contact angle (?o) and color change (?E) were evaluated after 24h deionized water storage and after 15, 90 and 180 days of red wine storage. Data were analyzed using Repeated Measures ANOVA and Tukey test (? = 0.05). The red wine storage time negatively influenced all variables, irrespective of treatment or resin composite. The SiO2 coating application decreased the surface free energy, making the composite more hydrophobic. The increase in surface roughness was observed from 90 days for all composites, regardless of treatment. Significant less color change was observed in the Filtek Z250XT and the IPS Empress Direct compared to Filtek Z350XT. In the second chapter, the groups were: PER-commercial resin-based coating (PermaSeal); STD-standard manipulated resin (Bis-EMA+TEGDMA-based monomer matrix loaded with 10% of inorganic filler); SIL-standard resin modified by SiO2 nanoparticles adding; APS-standard resin modified by acrylated polysiloxane adding (n = 10). The degree of resin conversion (%) Water sorption and solubility (mg/mm3) and elasticity modulus (GPa) were evaluated in massive specimens prepared from the resin-based coatings. These resin-based coatings were applied on the composite resin discs surfaces (Filtek Z250XT) to water contact angle (?o) and color change (?E) tests. A control group without surface treatment was included in these trials. The ?E was calculated from measurements taken before and after 15 days of red wine storage. The results were analyzed using one - way ANOVA and Tukey test (? = 0.05). The addition of SiO2 promoted lower solubility, appropriate elasticity modulus and lower degree of color change, and; the incorporation of acrylated polysiloxane provided better degree of conversion, reduced water sorption, the highest hydrophobicity and cause less color change compared to that of controls. Therefore, the incorporation of hydrophobic additives did not negatively affect the physical properties of the resin-based coatings and were effective to make the composite more hydrophobic and less stain susceptible / Mestrado / Dentística / Mestra em Clínica Odontológica
33

The role of surface properties on the physical attributes and stability of cocoa powder systems

Hector Lozano Perez (9192797) 03 August 2020 (has links)
<div>Cocoa is widely used by confectionary industries as a powder raw material for chocolate production. The chemical properties such as high- or low-fat content determine the functionality of the cocoa powder and constitute as a major factor in controlling the behavior of the final product. Additionally, the physicochemical properties such as the cohesive characteristics of cocoa powders create undesirable issues in industrial manufacturing settings. Thus, the evaluation of physical and chemical attributes is relevant to differentiate the powder surface structure and define the material behavior in presence of other materials or distinct environments.</div><div>This work evaluated three kinds of cocoa powders—varying mainly on the lipid content—to assess the powder performance in terms of the role of surface properties on the physical attributes (flowability and wettability) and stability under distinct frameworks. Various analytical tools were used, and several methodologies were developed and implemented to determine the surface area, changes in lipid melting phases at the surface level and particle interactions. The characterization methods included particle true density, flow properties under aerated conditions, bulk permeability, thermal properties, surface energetics, water sorption, and chemical surface compositional analyses.</div><div>The findings of this work revealed that the cocoa surface composition, amount of lipids, did not explain the low-flow performance or the water uptake. On the other hand, physicochemical properties such as lipid polymorphism was introduced as an avenue to further understand the results. From the surface energetics standpoint, a water diffusion mechanism is proposed as a result of the observed effect of water on the performance and stability of the cocoa powder systems. Owing to the hydrophobic nature of cocoa particles, this material can be used as a unique reference to understand cohesive particle models with implications on the performance (flowability and wettability) of lipid-based surface materials. The results indicated that powder behavior on the performance is a confounding effect of all variables.</div><div>The major contribution of this thesis work demonstrates the importance of surface chemistry characterization on the physical attributes of cocoa powder systems and the potential to control surface composition to improve the performance and stability of food complex systems.</div>
34

Electrochemical deposition, characterisation of metal films, and the modification of electrodes by near-field photolithography

Mallett, Jonathan James January 2000 (has links)
No description available.
35

The wind field in coastal areas / Vindfältet i kustnära områden”

Sondell, Niklas January 2001 (has links)
The land-sea transition in coastal areas makes the meteorological conditions rather complex and the structure of the coastal boundary layer is important for many reasons. Two examples are air pollution dispersion and wind energy potential. The wind field off the coast when offshore flow is present has been studied. At the coast there is a sudden change in surface properties that will affect the wind field in the area. When warm air is advected out over the much colder sea we get a stable stratification whose structure depends on wind speed and temperature difference. The roughness length over the sea is much less than over land, which gives less friction over the sea and usually increased winds. This is the general situation. But with a stable stratification the wind speed decreases near the surface partly due to the much denser air. However, there may be a wind speed decrease a certain distance from the coast, after an initial wind speed maximum. This is due to the growth of a stable internal boundary layer that develops over the sea. What is new in this investigation is that the more stable the stratification over the sea is, the farther offshore the decrease in wind speed occurs, probably more than 30 km. Thus with a very stable stratification the wind speed off the coast in coastal areas seems to be increased instead of decreased. This investigation also includes an explanation of why this behavior seldom is seen in measurements. The wind field structure dependence of the IBL-height and the stability has been studied and an expression for the distance to the decrease in wind speed has been found. Also the prediction of a sea breeze circulation is studied as well as the affect a low-level jet has on the wind field near the coast. Measurements from three sites are used, the Baltic Sea near the Island of Gotland, around the strait of Öresund and outside the Atlantic coast near Duck in North Carolina, USA. These measurements are used in simulations with a 2-dimensional meso-γ-scale model as well as a lot of arbitrary simulations. All simulations correspond very well to the expression found and the simulated cases agree well with the measured ones. In the lowest 100 m of the marine atmosphere over the Baltic Sea, the stratification is probably stable more than half of the year. Thus the behavior of decreased wind speeds a certain distance offshore, after an initial increase, would be a very common phenomenon. It must be of great importance in extracting wind energy, to avoid these areas and layers with decreasing wind speed, which in turn have lower wind energy potential. In an area with often very stable stratification over the sea there can be an energy loss of more than 50 % in the lowest 50 m of the boundary layer. / Sammanfattning av ”Vindfältet i kustnära områden” Övergången mellan land och hav gör de meteorologiska förhållandena i kustnära områden komplicerade. Vetskap om egenskaperna hos gränsskiktet vid kusten är viktigt av flera orsaker. Några exempel är spridning av luftföroreningar, vindenergipotential samt det faktum att man ska kunna ge rätt vindprognos till dem som av nytta eller nöje befinner sig utanför kusten. Vindfältet utanför kusten vid frånlandsvind har studerats här. Vid kusten sker en plötslig ändring av ytans egenskaper. När varm luft strömmar ut över kallt hav fås en stabil skiktning som beror på vindhastighet och temperaturdifferensen mellan land och hav. Skrovlighetslängden är större över land än över hav. Det ger vanligtvis en ökning av vindhastigheten över havet då luften strömmar från land till hav. Men vid tillräckligt stabil skiktning över hav samt med instabil skiktning över land fås istället ett vindavtagande. Initialt ökar dock alltid vindhastigheten. Det beror på tillväxten av ett internt gränsskikt. Höjden på detta måste vara tillräcklig för att ett avtagande skall ske. Stabilare skiktning över hav ger längre sträcka till avtagandet i vindhastighet som kan ske mer än 30 km utanför kusten och det kan inte längre kallas för kustnära område. Varför detta beteende sällan upptäcks utreds också. Vindfältets beroende av interna gränsskiktets höjd samt stabiliteten har studerats och ett uttryck för att beräkna avståndet till avtagandet i vindhastighet har också tagits fram. Även möjligheten att förutspå en sjöbris har studerats liksom den effekt en low-level jet har på vindfältet nära kusten. Mätningar från tre platser används, Östersjön nära Gotland, över Öresund samt vid Atlantkusten nära Duck i North Carolina, USA. Dessa tre fall simuleras i en 2-dimensionell modell liksom en mängd godtyckliga simuleringar av olika fall. I de lägsta 100 metrarna av det marina gränsskiktet över Östersjön är skiktningen troligen stabil mer än halva året. Beteendet med initialt ökande vindhastighet följt av en dramatiskt avtagande en viss sträcka utanför kusten borde vara ett vanligt fenomen. Vid utvinning av vindenergi måste det vara av stort intresse att undvika dessa områden med lägre vindhastighet, som i sin tur har lägre vindenergipotential. I ett område där det ofta blir stabilt skiktat över havet kan energiförlusten bli på över 50 % i de lägsta 50 metrarna av gränsskiktet.
36

Avaliação clínica e laboratorial de uma solução experimental à base de Ricinus communis em comparação ao hipoclorito de sódio para higiene de próteses totais / Clinical and laboratorial evaluation of an experimental solution based on Ricinus communis compared to sodium hypochlorite for denture cleansing

Badaró, Mauricio Malheiros 06 December 2013 (has links)
Este estudo clínico-laboratorial avaliou uma solução à base de Ricinus communis para higiene de próteses totais, comparando-a ao hipoclorito de sódio, quanto à efetividade na remoção do biofilme, remissão de Candidíase Atrófica Crônica, grau de satisfação dos pacientes e rugosidade superficial da resina acrílica termopolimerizada. Sessenta e quatro usuários de próteses totais com ausência (n=40) ou presença de Candidíase (n=24) foram selecionados e orientados a escovar as próteses com escova específica e sabão neutro por 3 minutos, 3 vezes ao dia e imergi-las nas soluções de higiene (Hipoclorito de sódio 0,25% - S1; e 0,5% - S2; R. communisa 10% - S3; Salina - S4: controle) por 20 minutos. As soluções foram utilizadas de forma cruzada e randomizada com períodos de \"wash out\". Para quantificação do biofilme (ImageTool 3.0), a superfície interna foi evidenciada (vermelho neutro 1%) e fotografada ao final de cada período. A remissão da Candidíase foi avaliada por atribuição de escores antes e após o uso das soluções. A satisfação dos pacientes foi analisada por questionário. A rugosidade da superfície polida e não polida de 40 espécimes (90x30x4mm) de resina foi avaliada antes e após a exposição dos mesmos ao protocolo clínico de higiene por meio de rugosímetro e Microscopia Eletrônica de Varredura. A remoção do biofilme foi analisada como um \"split-plot\" com dois fatores de variação: presença de inflamação e soluções. A remissão da Candidíase foi analisada após ajuste dos dados por regressão logística multinomial. Para análise da satisfação dos pacientes os dados foram ajustados por regressões logísticas e foi adotada análise de simetria composta. Para avaliação da rugosidade das superfícies polida e não polida foi empregada análise de variância com dois fatores (período e solução). Todas as análises foram realizadas com nível de significância de 5%. Não houve diferença na porcentagem de biofilme entre pacientes com e sem inflamação, bem como na interação entre os fatores. Houve diferença entre soluções, sendo que o Hipoclorito de sódio a 0,25 e 0,5% promoveu as menores médias de biofilme (4,41±7,98 e 2,93±5,23), seguido do R. communis(6,95±10,93) e Salina (11,07±11,99). Para remissão da Candidíase, as soluções mais eficientes foram R. communis(50%) e Hipoclorito de sódio 0,25% (46%). O questionário de satisfação não indicou diferença entre as soluções. A rugosidade da superfície polida não foi alterada pelo período (p=0,062). Houve alteração em função das soluções (p=0,00) e da interação entre os fatores (p=0,005). Para S1 e S4, o período não influenciou na rugosidade. Para S2, houve alteração a partir de 07 dias, permanecendo estável após 14 dias. Para S3, houve alteração e estabilização a partir de 14 dias. Após 07 e 14 dias, S2 e S3 promoveram as maiores alterações, porém após 21 dias, não houve diferença entre as soluções, exceto a salina. A superfície não polida não foi influenciada pelos fatores período (p=0,358), solução (p=0,120) e interação (p=0,204). Concluiu-se que há viabilidade do uso do hipoclorito de sódio em menores concentrações e do Ricinus communis para remoção do biofilme, remissão da Candidíase e controle da rugosidade superficial. / This clinical-laboratory study evaluated a solution based on Ricinus communis for denture cleansing, comparing it to sodium hypochlorite, regarding biofilm removal capacity, remission of atrophic chronic candidiasis, degree of patient satisfaction and surface roughness of heat-polymerized acrylic resin. Sixty-four denture wearers with absence (n = 40) or presence of Candidiasis (n = 24) were selected and oriented on how to brush their dentures with a specific brush and mild soap for 3 minutes, 3 times a day and immerse them in hygiene solutions (0.25% sodium Hypochlorite - S1 and 0.5% - S2, R. communis 10% - S3; Saline - S4: control) for 20 minutes. The solutions were used in a randomized and cross form with \"washout\" periods. To quantify biofilm (ImageTool 3.0), the inner surface was disclosed (1% neutral red) and photographed at the end of each period. The remission of Candidiasis was assessed by assigning scores before and after using solutions. Patient satisfaction was assessed by questionnaire. The surface roughness of 40 polished and unpolished resin specimens (90x30x4mm) was evaluated before and after their exposure to clinical protocol hygiene by surface roughness and scanning electron microscopy. The biofilm removal was analyzed as a \"split-plot\" with two variation factors: inflammation and solutions. The candidiasis remission was analyzed after adjustment using multinomial logistic regression. For patient satisfaction logistic regression analysis was adopted and compound symmetry. For evaluation of surface roughness polished and unpolished was employed analysis of variance with two factors (time and solution). All the analysis were performed with a significance level of 5 %. There was no difference in the percentage of biofilm between patients with and without inflammation, as well as the interaction between the factors. There were differences among the solutions, having the Sodium Hypochlorite 0.25 % and 0.5% promoted the lowest average biofilm (4.41±7.98 and 2.93±5.23), followed by R. communis (6.95±10.93) and Saline (11.07±11.99) . For the remission of candidiasis, the most efficient solutions were R. communis (50%) and 0.25% sodium hypochlorite (46%). The satisfaction questionnaire indicated no difference among the solutions. The roughness of the polished surface was not affected by time (p = 0.062). There was a change in function of the solutions (p = 0.00) and the interaction between factors (p = 0.005). For S1 and S4, the period did not influence the roughness. For S2, there was a change from 07 days, remaining stable after 14 days. For S3, there were changes and stabilization from 14 days. After 7 and 14 days, S2 and S3 promoted major changes, but after 21 days, there were no difference among the solutions except the saline. The unpolished surface is not influenced by factors: period (p = 0.358), solution (p = 0.120) and interaction (p = 0.204). It was concluded that there is feasibility for using sodium hypochlorite at lower concentrations and Ricinus communis for the removal of biofilm, remission of candidiasis and control of surface roughness.
37

Estudo comparativo da interação celular entre quatro tipos de implantes dentários / Comparative study of cellular interactions between four types of dental implants

Alves, Fabiana Ferreira 26 February 2015 (has links)
O tratamento de superfície dos implantes dentários é um critério importante para a osseointegração. Considerando a variedade de modificações das superfícies encontradas, estas podem acelerar ou melhorar o processo de osseointegração. Para tanto foram estudadas as características da composição química e a rugosidade, a partir das quais foram encontradas diferentes respostas celulares em estudos comparativos in vitro. O objetivo deste estudo foi comparar a adesão e o crescimento dos OSTEO-1 em implantes dentários com diferentes tratamentos de superfície. Foram utilizados quatro tipos de implantes dentários comercialmente disponíveis, com os seguintes tratamentos de superfície: (A) jateamento e condicionamento ácido com revestimento de fosfato e cálcio (CaP); (B) duplo condicionamento ácido; (C) condicionamento ácido; (D) oxidação anódica. Os implantes de mesmo tamanho foram fixados com dispositivo biocompatível no fundo dos poços das placas de cultura de 12 poços e cobertas com meio de cultura de células. Os OSTEO-1 foram colocados no corpo do implante. Nos períodos de 24, 48 e 72 horas mais tarde, as culturas foram submetidas ao ensaio de redução de MTT para avaliar a viabilidade celular. Os dados foram utilizados para analisar a adesão celular (24h) e para obter as curvas de crescimento das células (24, 48 e 72h). Os experimentos foram realizados em triplicata. Os dados foram comparados por ANOVA, complementado pelo teste de Tukey (p <0,05). Os OSTEO-1 aderiram ao corpo de todos os tipos de implantes testados. A maior taxa de crescimento celular foi observada em culturas semeadas sobre tratamento de superfície A. O menor crescimento celular foi apresentado por culturas semeadas no tratamento de superfície D (p <0,05). Com base nesta investigação in vitro é possível concluir que todos os implantes dentários testados, independentemente do tratamento de superfície, não são citotóxicos para os OSTEO-1. No entanto, as características físico-químicas do tipo de tratamento de superfície dos implantes dentários influencia o crescimento celular. A superfície A pareceu ter o comportamento mais compatível com os OSTEO-1, uma vez que promoveu mais crescimento celular. / The surface treatment of dental implants is a major feature for osseointegration. The variety of surface modifications found may be speed up or enhance the osseointegration process. In much was studied the chemical composition and characteristics of roughness, from which found different cellular responses in comparative studies in vitro.The aim of this study was to compare the adhesion and growth of osteoblast-like cells in response to dental implants characterized by different superficial treatments. Four types of dental implants with different superficial treatments were used. The commercially available implants presented the following superficial characteristics: (A) sandblasted with acid-etched and calcium phosphates (CaP) coating; (B) double acid-etched; (C) anodized, or (D) acid-etched. The implants of the same size (n= 3 per group/experimental time) were fixed with a biocompatible device on the bottom of the wells of 12 wells cell culture plates and covered with cell culture medium. Osteoblast-like cells (Osteo 1 cell line) were plated on the top of the implants (5x104 cells/implant). Twenty-four, 48 and 72 hours later, the cultures were submitted to the MTT reduction assay to assess cell viabilities. Data was used for analyze cell adhesion (24 h) and to obtain cell growth curves ( 24, 48 and 72 h). The experiments were done in triplicate. Data were compared by ANOVA complemented by the Tukey\'s test (p<0.05). Osteoblast-like cells adhered on the top of all types of implants tested. The highest cell growth was observed in cultures plated on the top of sandblasted with acid-etched and CaP coating surfaces. The smallest cell growth was presented by cultures plated on double acid-etched surfaces (p < 0.05). Based on this in vitro investigation, it is possible to conclude that all dental implants tested irrespective to the surface treatment, are non-cytotoxic for osteoblast-like cells. However, the physicochemical chacteristics of the type of dental implants surface treatment influences the cell growth. In fact, the surface treated by sandblasting with acid-etched and CaP coating seemed to the most compatible with osteoblast-like cell biology, once it promoted the highest cell growth.
38

Tratamento de superfície de porcelanas dentárias pela irradiação com laser de CO2 / Surface treatment of dental porcelains with CO2 laser

Sgura, Ricardo 04 July 2013 (has links)
Este estudo teve como objetivo testar o laser de CO2 como um agente de tratamento de superfície de porcelanas dentárias. Material e Métodos: O estudo foi dividido em duas etapas: na primeira etapa, discos de porcelana (3,5 mm diam. x 2,0 mm espess.) das marcas VM7, VM9 e VM13 (VITA) foram sinterizados e tiveram uma de suas faces asperizadas por uma ponta diamantada 2134F para acabamento. Os espécimes foram então divididos em grupos de acordo com os seguintes tratamentos: nenhum (C), auto-glaze em forno (G) e irradiação com laser (L) de CO2 (Coherent, = 10,6 m, 35 W) de forma contínua com 40, 45 ou 50 W/cm2 nos tempos de 3, 4 ou 5 minutos (n=7). Nesta primeira etapa, as caracterizações das amostras constaram de: difratometria por raios-X, diferença de cor (Easyshade VITA), rugosidade superficial (Surftest 301, Mitutoyo) e análise visual por meio de esteromicroscopia e MEV. Um espécime de VM9 de cada grupo foi polido e levado a um exame por microscopia de força atômica (MFA). A segunda etapa consistiu na sinterização de discos das três porcelanas nas mesmas dimensões da etapa anterior, porém submetidos a um polimento de uma das superfícies com soluções diamantadas de granulação decrescente até 1 m. Os grupos testados foram os mesmos da primeira etapa, com exceção dos grupos irradiados com 40W/cm2. As caracterizações que se seguiram foram (n=10): microdureza Vickers, tenacidade à fratura, porosidade superficial, razão de contraste (RC) e capacidade de mascaramento (CM). Resultados: A rugosidade de espécimes asperizados foi diminuída pela aplicação do laser nas irradiâncias de 45 e 50 W/cm2, similar ao auto-glaze em forno, sem alteração de cor perceptível para a quase totalidade dos grupos irradiados. Houve um aumento do conteúdo cristalino das porcelanas VM9 e VM13 após a irradiação com o laser. As micrografias (MEV) demonstraram padrão de superfície homogêneo para os espécimes dos grupos irradiados a 50 W/cm2 e G. Os resultados da segunda etapa apontaram para alterações na microdureza e tenacidade à fratura na dependência da marca comercial e das irradiâncias estudadas. Quanto à porosidade, as porcelanas VM7 e VM13 apresentaram um aumento na fração volumétrica de poros, enquanto a porcelana VM9 irradiada apresentou-se semelhante a G. As médias de RC e CM indicaram um aumento na opacidade das porcelanas VM7 e VM13 irradiadas com o laser. Conclusão: Em condições específicas, o laser de CO2 é capaz de produzir uma lisura de superfície semelhante ao auto-glaze, com pequenas alterações nos aspectos ópticos e mecânicos. As diferentes marcas comerciais de porcelana apresentaram comportamentos distintos em relação aos tratamentos aplicados. / Glazing porcelain is an important procedure in dentistry that leads to surface smoothness, to less plaque accumulation and to brightness, especially after a chair side adjustment. Despite a good absorption of CO2 laser wavelength by dental porcelain it has not yet been tested as an alternative to oven glaze. Aim: This study tested CO2 laser as a heat source in surface treatment of dental porcelains. Material and Methods: This study was divided in two stages: at the first stage porcelain discs (VM7, VM9, VM13 VITA; 3.5 diam. x 2.0 mm thickness) were sintered, machined and had one of their sides grounded by a diamond bur (2134F KG Sorensen) simulating a chair side adjustment in clinical office. Specimens were then divided into groups according to treatment: no treatment (C); auto-glazed in conventional furnace (G) and submitted to CO2 continuous laser irradiation (Coherent, = 10.6 m; output power = 35 W, 0.5 cm laser beam) in 40, 45 or 50 W/cm2 for 3, 4 or 5 minutes (n=7). Specimens were supported by a ceramic refractory. At this first stage, the characterization consisted of X-ray diffraction (RU-200B, Rigaku), color difference (E) (Easyshade VITA), roughness (Surftest 301, Mitutoyo) and analysis of images achieved by stereomicroscopy (SZ61, Olympus) and SEM (Stereoscan 440, LEO). A VM9 specimen of each group had one of their side polished and was submitted to atomic force microscopy (AFM) Nanoscope IIIA (Veeco). In the second stage discs with the same dimension described above were sintered and polished with diamond solutions (Ecomet 3; 1 m). The same groups were tested except 40W/cm2 irradiance. Specimens were submitted to the following characterizations (n=10): Vickers microhardness test, fracture toughness by indentation fracture (HMV, Shimadzu), surface porosity (HMV, Image J software), contrast ratio (CR) and masking ability (MA) (CM-3770d, Konica Minolta). Results from both stages were submitted to one-way-ANOVA or Kruskall-Wallis test. A post-hoc Tukey test was applied when necessary ( = 0.05). Results: Ground specimens showed a reduction in roughness after laser irradiation (45 and 50 W/cm2), comparable to oven-glazed specimens with almost no color change. SEM images presented similarity between a irradiated group (50W/cm2) and G. AFM test revealed the formation of long rounded peaks and long valleys after laser exposition. Second stage results pointed to changes in microhardness and fracture toughness of irradiated specimens depending on the porcelain and irradiance tested. Regarding porosity, after laser exposition, porcelain VM7 and VM13 presented an increase in pores (area fraction) for the majority of groups while VM9 porcelain didnt show any increase in porosity after laser incidence. CR and MA means pointed to an increase in porcelain opacity to irradiated specimens of VM7 and VM13. Conclusion: Under specific conditions CO2 laser was able to produce a surface smoothness similar to auto-glaze, despite punctual changes in some optical and mechanical properties. The different brands presented distinct effects after laser heat treatment.
39

Propriedades mecânicas e avaliação microscópica de fios ortodônticos de niti revestidos por polímeros / Mechanical properties and microscopic avaliation wire niti coated in polymers

Ferreira, Gaudyer Castro Di 24 March 2015 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-23T11:24:55Z No. of bitstreams: 2 Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2016-02-23T11:27:08Z (GMT) No. of bitstreams: 2 Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) / Made available in DSpace on 2016-02-23T11:27:08Z (GMT). No. of bitstreams: 2 Dissertação - Gaudyer Castro di Ferreira - 2015.pdf: 12501436 bytes, checksum: 06af9912db4067aacec6a4dec872f91a (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2015-03-24 / The objective of the study was to analyze the mechanical properties and analyze the surface of the wires coated polymers. Methods: We used the pre-contoured wires study with dimension of 0.014 "Nickel- Titanium (NiTi) brands: Tecident orthodontic equipment Ltda (São Carlos, São Paulo Brazil), TP Orthodontics (Indiana, USA), Trianeiro ( Rio Claro, São Paulo Brazil) and NiTi wire Morelli (Sorocaba, Sao Paulo Brazil) as a control group. The yarns were randomly divided into 11 groups (n = 6) .There were carried deflection test. The yarns were immersed in artificial saliva for a period of 30 to 60 days to corrode. After the wire corrosion were also submitted for the analysis of Scanning Electron Microscopy (SEM). Results: We used the ANOVA analysis of variance, which were statistically significant differences between the tested wire and the controle.Foram group observed imperfections on the surfaces of all the wire and the wire TP Orthodontics showed the greatest changes. Conclusions: The polymeric coating appears to be responsible for the mechanical surface change and the NiTi wires. / O objetivo do estudo foi analisar as propriedades mecânicas e analisar a superfície, dos fios revestidos por polímeros. Materiais e métodos: Foram utilizados no estudo fios pré-contornados com dimensão de 0.014” de Niquel-Titânio (NiTi) das marcas: Tecident Equipamento Ortodonticos Ltda(São Carlos,São Paulo Brasil), TP Orthodontics (Indiana, EUA) , Trianeiro (Rio Claro, São Paulo Brasil) e fio NiTi Morelli ( Sorocaba, São Paulo Brasil) como grupo controle. Os fios foram divididos aleatoriamente em 11 grupos (n=6).Foram realizado o teste de deflexão. Os fios foram imersos em saliva artificial por um período de 30 e 60 dias,para sofrer corrosão. Após a corrosão os fio também foram submetidos para a análise de Microscopia Eletrônica de Varredura (MEV). Resultados:Foi utilizado o teste de variância ANOVA, onde foram observadas diferenças estatisticamente significantes entre os fios testados e os do grupo controle.Foram observadas imperfeições nas superfícies de todos os fio sendo que o fio da TP Orthodontics apresentou as maiores alterações. Conclusões: O revestimento polimérico parece ser o responsável pelas alterações mecânicas e da superfície dos fios de NiTi.
40

Efeito da degradação biológica seguida da escovação sobre propriedades de superfície de materiais restauradores estéticos / Evaluation of the surface properties of aesthetic restorative materials exposed to biological degradation followed by toothbrushing

Medeiros, Bianca 04 February 2015 (has links)
Made available in DSpace on 2017-07-10T14:57:29Z (GMT). No. of bitstreams: 1 _bianca.pdf: 1155303 bytes, checksum: 22972da42ac700f304075d9d96bc2aa3 (MD5) Previous issue date: 2015-02-04 / Aesthetic restorative materials must withstand the adversities of the oral environment, suffering minimal degradation. This study evaluated the roughness (Ra), Knoop hardness (KHN) and change of color (&#916;E) of esthetic restorative materials subjected to contact with biofilm of Streptococcus mutans associated with abrasion generated by brushing. 10 disks (8 mm diameter; 2 mm deep) of each material were prepared (Filtek Z350, composite nanoparticle; Empress Direct, composite nanohybrid and IPS e.Max, ceramic). The ceramic disks received application of glaze. The composites were stored in 100% relative humidity, after 24 h, the composites were polished with sequential abrasive discs. Then, all specimens were stored in 100% relative humidity at 37°C for 24 hours, and so, evaluated the properties of initial surface. The specimens were sterilized with ethylene oxide; and after undergoing biological degradation, by 25 &#956;L Streptococcus mutans inoculum with optical density (OD) standard, maintained by 2 h on discs. The specimens were immersed in brain-heart infusion (BHI) medium with 1% sucrose, which was changed every 48 h. After 7 days, all disks were washed in ultrasound, and evaluated the surface properties again. Finally, the specimens were subjected to a mechanical degradation, being fixed to a device of brushing and worn through for dental bristles, with toothpaste, and after this process, were measured, once again, the surface properties. Data were analyzed by Proc-Mixed and Tukey (&#945; = 0.05). Initially e.Max showed higher Ra and KHN; after biological degradation, the composites showed increased Ra, but KHN has not changed; later the mechanical degradation Empress had its Ra decreased and KHN increased to Z350, and all had lightness increased. The results suggest that when exposed to Streptococcus mutans biofilm and toothbrush abrasion, ceramic undergoes minimal degradation; the nanoparticulate composite promoted increased roughness and composites exhibit variable degradation, depending on the composition of the material. / Materiais restauradores estéticos devem resistir às adversidades do meio bucal, sofrendo mínima degradação. Este estudo avaliou a rugosidade (Ra), dureza Knoop (KHN) e alteração de cor (&#916;E) de materiais restauradores estéticos submetidos ao contato com biofilme de Streptococcus mutans associado a abrasão gerada pela escovação. Foram confeccionados 10 discos (8 mm de diâmetro por 2 mm de espessura) de cada material (Filtek Z350, resina composta nanoparticulada; Empress Direct, resina composta nanohíbrida e IPS e.Max, cerâmica). Os discos de cerâmica receberam aplicação de glaze. Os compósitos foram armazenados em umidade relativa 100%, por 24 h, após, realizou-se o polimento dos compósitos com discos abrasivos sequenciais. Então, todos os espécimes foram armazenados em umidade relativa 100% a 37ºC por 24 h, sendo assim, avaliadas as propriedades de superfície iniciais. Os espécimes foram esterilizados em óxido de etileno; e submetidos a degradação biológica através da inoculação de 25 &#956;L de Streptococcus mutans com densidade ótica (DO) padronizada, mantido por 2 h sobre os discos. Os espécimes foram imersos em meio brain heart infusion (BHI) com 1% de sacarose, o qual foi trocado a cada 48 h. Após 7 dias, todos os discos foram lavados em ultra-som, e avaliadas as propriedades de superfície novamente. Por fim, os espécimes foram submetidos a degradação mecânica, sendo fixos a um dispositivo de escovação e desgastados através das cerdas dentais, via dentifrício, e, após esse processo, foram mensuradas, mais uma vez, as propriedades de superfície. Os dados foram analisados pelos testes Proc-Mixed e Tukey (&#945; = 0,05). Inicialmente e.Max apresentou maior Ra e KHN; após a degradação biológica os compósitos tiveram aumento de Ra, porém, a KHN não se alterou; já posteriormente a degradação mecânica, Empress teve sua Ra diminuída e a KHN aumentou para o Z350, e todos tiveram aumento da luminosidade. Os resultados permitem concluir que, quando expostos ao biofilme de S. mutans e à abrasão por escovação, a cerâmica sofre mínima degradação e os compósitos sofrem degradação variável, dependendo da sua composição

Page generated in 0.4718 seconds