Spelling suggestions: "subject:"asurgical clinics."" "subject:"cirurgical clinics.""
1 |
The impact of day surgery unit on nursing roles and functions :Barredo, Maria Victoria. Unknown Date (has links)
Thesis (MNursing (Advanced Practice))--University of South Australia, 1996
|
2 |
Proposta de acolhimento pré-operatório de enfermagem como intervenção no cancelamento de cirurgias entre os usuários do SUS / A proposal for pre operation admission by nursing staff as means of reducing cancellation of surgery among SUS patientsSilva, Grácia Maria Garcia 28 February 2018 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2018-04-24T12:27:13Z
No. of bitstreams: 1
Grácia Maria Garcia Silva.pdf: 1921629 bytes, checksum: 11acbb31f2a9d74c5cce8f0746ba8a8d (MD5) / Made available in DSpace on 2018-04-24T12:27:14Z (GMT). No. of bitstreams: 1
Grácia Maria Garcia Silva.pdf: 1921629 bytes, checksum: 11acbb31f2a9d74c5cce8f0746ba8a8d (MD5)
Previous issue date: 2018-02-28 / The cancellation of surgeries is significant in many hospitals, not only in Brazil. The motifs
are repeated in all studies, varying only by orders, and most are avoidable causes. All
cancellation creates stress for the patient and burden the institution, also reflecting
inefficiency in management. Faced with this reality, in which SUS (Health Unic System)
patients are the most impaired, the work proposes a nursing intervention to reduce
cancellations of surgeries for these patients. The study, conducted with 159 SUS patients with
scheduled elective surgeries, consisted of a nursing consultation and an active search
(telephone contact with the patient or family member) 48 hours before the surgery. A
retrospective study was also performed on the surgical procedures performed and suspended,
by specialty, reason for suspension and source of payment (SUS, Agreement and Particular)
from January 2014 to November 2017. The average number of suspensions of research
surgeries was 17.0%, above the historical average (10.4%) and the historical average of SUS
(14.0%). The rate of suspension when there was contact with the patient or with a relative was
15.3%, lower than the rate when there was no contact (22.0%). As the percentages of patientrelated
causes (44.4%) were similar to non-relative ones (55.6%), joint action is
recommended between health teams and the institution, in order to reduce cancellation of
surgeries / O cancelamento de cirurgias é significativo em muitos hospitais, não apenas do Brasil. Os
motivos se repetem em todos os estudos, variando apenas as ordens, e a maioria são causas
evitáveis. Todo cancelamento gera stress para o paciente e onera a instituição, refletindo
também ineficiência na gestão. Diante desta realidade, na qual os pacientes do SUS são os
mais prejudicados, o trabalho propõe uma intervenção de enfermagem para diminuir os
cancelamentos das cirurgias para esses pacientes. O estudo, feito com 159 pacientes do SUS
com cirurgias eletivas agendadas, foi composto de uma consulta de enfermagem e de uma
busca ativa (contato telefônico com o paciente ou familiar), 48 horas antes da cirurgia. Foi
feito, também, um estudo retrospectivo sobre as cirurgias agendas, realizadas e suspensas, por
especialidade, motivo de suspensão e fonte pagadora (SUS, Convênio e Particular) de janeiro
de 2014 a novembro de 2017. A média de suspensões de cirurgias da pesquisa foi de 17,0%,
acima da média histórica geral (10,4%) e da média histórica do SUS (14,0%). A taxa de
suspensão quando houve o contato com o paciente ou com um familiar foi de 15,3%, inferior
à taxa de quando não houve o contato (22,0%). Como os percentuais de causas relativas aos
pacientes (44,4%) foram semelhantes aos não relativos (55,6%), recomenda-se uma ação
conjunta entre as equipes de saúde e a instituição, de modo a diminuir os cancelamentos de
cirurgias
|
3 |
Intensidades de campos elétricos em centros cirúrgicos: um estudo in situMoura, Marcos Antonio Muniz de 11 December 2007 (has links)
Este trabalho apresenta um estudo de medições de intensidades de campos elétrico em um centro cirúrgico, oriundos de fontes de radiofreqüência comerciais operando na cidade de Curitiba, no Paraná. Com o aumento da telefonia celular e, por conseguinte, de suas torres somando-se às antenas de televisões, rádios, rádios chamadas, redes de dados sem fio, internet por ondas de rádio, microondas, serviço de rádio da polícia, dos bombeiros, de rádio táxi, rádio amador, GPS, etc., o que acaba provocando um tipo de poluição eletromagnética “no ar”. Tal poluição pode trazer problemas tanto para o meio ambiente como para a saúde e, entre as tecnologias, possíveis interferências entre as mesmas podendo, por vezes, levar equipamentos a executarem funções imprevisíveis. Conhecer os valores de intensidade desses campos torna-se relevante, principalmente em um hospital onde vidas humanas podem estar a perigo quando conectadas a equipamentos susceptíveis a falhar em suas funções devido à presença desses campos. Os resultados obtidos neste trabalho são comparados com os recomendados pelas principais agências regulamentadoras. Após definido um hospital com o maior número de antenas em seu contorno, montou-se um setup de ensaios em seu centro cirúrgico, observando as distâncias mínimas possíveis entre paredes, teto, chão, luminária e entre as antenas. O setup encontra-se a 1920 cm na direção frontal e a 900 cm na direção lateral direita, posição essas que serviram como referência para o posicionamento do GPS no terraço para a obtenção das coordenadas geográficas. Os equipamentos utilizados foram: um receptor de sinais seletivos, um notebook com um software utilizado na operação do receptor e na aquisição dos dados, uma antena seletiva e um medidor de campo elétrico isotrópico. Foram selecionados 11 canais de televisões, 16 de rádios FM e 13 estações de rádio base (telefonia celular). Nos resultados das medições seletivas, os valores encontrados de 0,005 V/m comparados com as recomendações mais rigorosas (ONIR/Suíça) que é de 4,0 V/m ficando então os valores medidos 0,13% desse valor. Na faixa especifica da ONIR (900 & 1900), ou seja, GSM, este trabalho encontrou 0,0068 V/m ou 0,14% em relação aos valores preconizados por ela para as exposições ocupacionais e de 0,17% para o público em geral.Em questão dos equipamentos médicos obteve-se 1,75 V/m medido contra 3 V/m da norma NBR/IEC60601-1-2, ou seja, um campo medido de 58,33% menor do valor aconselhado. Este trabalho recomenda principalmente: adotar o Princípio da Precaução, que prevê medidas protetoras antecipadas perante as incertezas e/ou riscos desconhecidos, na operação dos transmissores; exigir que todas as instalações de transmissores tenham EIA/RIMA-EIV e; realizar periodicamente medições no contorno desses transmissores para verificar o incremento dos campos elétricos de outras fontes, que se somaram aos dos mesmos. / The aim of this paper is to present a study of measurement of the intensity of electric fields in a surgery room coming from radio frequency broadcasting sources located in Curitiba, Paraná. This is a result of an increase in cellular telephony and, consequently, of its transmission towers which, along with radio and TV antennas, radio service calls, wireless networks, internet connections by means of radio waves, microwave ovens, police and firefighters radio calls, radio taxi service calls, amateur radio service, GPS, and so on, produce a kind of electromagnetic pollution “in the air”. Such pollution might cause problems for the environment as well as for people’s health and there might even be some interference concerning the technologies themselves, which might cause equipment to perform unpredictable functions. Thus, it is important to become aware of the level of the intensity of these fields, especially concerning hospitals where human lives might be in danger when they depend on equipment that is likely to fail due to the presence of these magnetic fields. The results obtained in our study are compared to those recommended by the main regulating agencies. After selecting a hospital with the greatest number of antennas around, we built an experimental setup inside a surgery room, observing the minimum distance required between the walls, between the ceiling and the floor, light equipment, and among the antennas. The set up was located 1920 cm to the front and 900 cm to the right lateral position, which served as reference for placing the GPS equipment in order to obtain geographical coordinates. The equipment used involved a selective signal receiver, a notebook with a software used to receive signals and collect data, a selective antenna and isotropic electric field measurement equipment. Eleven TV channels, 16 FM radio stations and 13 radio-based stations (cellular telephony stations) have been selected. Concerning selective measurement, the result obtained was 0,005 V/m and, when compared to the most rigorous recommendation (ONIR/Switzerland) which is 4,0 V/m, the result was 0,13% distant from the one suggested. Concerning ONIR specific band (900 & 1900), that is, GSM, our study has found 0,0068 V/m or 0,14% when compared to the results recommended by ONIR for occupational exposure and 0,17% for people’s exposure in general. Concerning medical equipment, our study has found 1,75 V/m, compared to 3 V/m, expected according to NBR/IEC60601-1-2, that is, the measured field was 58,33% lower than the one recommended. Therefore, we recommend that some actions be taken such as: adopting the Precautionary Principle, which proposes anticipated protective measures in relation to uncertainties and/or unknown risks, for using broadcasting equipment; demanding that all broadcasting facilities observe Environmental Impact Assessment Studies/EIRs – Neighboring Community Environmental Impact Studies; and, finally, performing periodical measurement of the surroundings in order to check the increase in magnetic fields from other sources which produce magnetic field pollution.
|
4 |
Intensidades de campos elétricos em centros cirúrgicos: um estudo in situMoura, Marcos Antonio Muniz de 11 December 2007 (has links)
Este trabalho apresenta um estudo de medições de intensidades de campos elétrico em um centro cirúrgico, oriundos de fontes de radiofreqüência comerciais operando na cidade de Curitiba, no Paraná. Com o aumento da telefonia celular e, por conseguinte, de suas torres somando-se às antenas de televisões, rádios, rádios chamadas, redes de dados sem fio, internet por ondas de rádio, microondas, serviço de rádio da polícia, dos bombeiros, de rádio táxi, rádio amador, GPS, etc., o que acaba provocando um tipo de poluição eletromagnética “no ar”. Tal poluição pode trazer problemas tanto para o meio ambiente como para a saúde e, entre as tecnologias, possíveis interferências entre as mesmas podendo, por vezes, levar equipamentos a executarem funções imprevisíveis. Conhecer os valores de intensidade desses campos torna-se relevante, principalmente em um hospital onde vidas humanas podem estar a perigo quando conectadas a equipamentos susceptíveis a falhar em suas funções devido à presença desses campos. Os resultados obtidos neste trabalho são comparados com os recomendados pelas principais agências regulamentadoras. Após definido um hospital com o maior número de antenas em seu contorno, montou-se um setup de ensaios em seu centro cirúrgico, observando as distâncias mínimas possíveis entre paredes, teto, chão, luminária e entre as antenas. O setup encontra-se a 1920 cm na direção frontal e a 900 cm na direção lateral direita, posição essas que serviram como referência para o posicionamento do GPS no terraço para a obtenção das coordenadas geográficas. Os equipamentos utilizados foram: um receptor de sinais seletivos, um notebook com um software utilizado na operação do receptor e na aquisição dos dados, uma antena seletiva e um medidor de campo elétrico isotrópico. Foram selecionados 11 canais de televisões, 16 de rádios FM e 13 estações de rádio base (telefonia celular). Nos resultados das medições seletivas, os valores encontrados de 0,005 V/m comparados com as recomendações mais rigorosas (ONIR/Suíça) que é de 4,0 V/m ficando então os valores medidos 0,13% desse valor. Na faixa especifica da ONIR (900 & 1900), ou seja, GSM, este trabalho encontrou 0,0068 V/m ou 0,14% em relação aos valores preconizados por ela para as exposições ocupacionais e de 0,17% para o público em geral.Em questão dos equipamentos médicos obteve-se 1,75 V/m medido contra 3 V/m da norma NBR/IEC60601-1-2, ou seja, um campo medido de 58,33% menor do valor aconselhado. Este trabalho recomenda principalmente: adotar o Princípio da Precaução, que prevê medidas protetoras antecipadas perante as incertezas e/ou riscos desconhecidos, na operação dos transmissores; exigir que todas as instalações de transmissores tenham EIA/RIMA-EIV e; realizar periodicamente medições no contorno desses transmissores para verificar o incremento dos campos elétricos de outras fontes, que se somaram aos dos mesmos. / The aim of this paper is to present a study of measurement of the intensity of electric fields in a surgery room coming from radio frequency broadcasting sources located in Curitiba, Paraná. This is a result of an increase in cellular telephony and, consequently, of its transmission towers which, along with radio and TV antennas, radio service calls, wireless networks, internet connections by means of radio waves, microwave ovens, police and firefighters radio calls, radio taxi service calls, amateur radio service, GPS, and so on, produce a kind of electromagnetic pollution “in the air”. Such pollution might cause problems for the environment as well as for people’s health and there might even be some interference concerning the technologies themselves, which might cause equipment to perform unpredictable functions. Thus, it is important to become aware of the level of the intensity of these fields, especially concerning hospitals where human lives might be in danger when they depend on equipment that is likely to fail due to the presence of these magnetic fields. The results obtained in our study are compared to those recommended by the main regulating agencies. After selecting a hospital with the greatest number of antennas around, we built an experimental setup inside a surgery room, observing the minimum distance required between the walls, between the ceiling and the floor, light equipment, and among the antennas. The set up was located 1920 cm to the front and 900 cm to the right lateral position, which served as reference for placing the GPS equipment in order to obtain geographical coordinates. The equipment used involved a selective signal receiver, a notebook with a software used to receive signals and collect data, a selective antenna and isotropic electric field measurement equipment. Eleven TV channels, 16 FM radio stations and 13 radio-based stations (cellular telephony stations) have been selected. Concerning selective measurement, the result obtained was 0,005 V/m and, when compared to the most rigorous recommendation (ONIR/Switzerland) which is 4,0 V/m, the result was 0,13% distant from the one suggested. Concerning ONIR specific band (900 & 1900), that is, GSM, our study has found 0,0068 V/m or 0,14% when compared to the results recommended by ONIR for occupational exposure and 0,17% for people’s exposure in general. Concerning medical equipment, our study has found 1,75 V/m, compared to 3 V/m, expected according to NBR/IEC60601-1-2, that is, the measured field was 58,33% lower than the one recommended. Therefore, we recommend that some actions be taken such as: adopting the Precautionary Principle, which proposes anticipated protective measures in relation to uncertainties and/or unknown risks, for using broadcasting equipment; demanding that all broadcasting facilities observe Environmental Impact Assessment Studies/EIRs – Neighboring Community Environmental Impact Studies; and, finally, performing periodical measurement of the surroundings in order to check the increase in magnetic fields from other sources which produce magnetic field pollution.
|
Page generated in 0.0636 seconds