• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Métodos para otimização de abertura dinâmica da nova fonte de luz síncrotron brasileira - Sirius / Methods for optmisation of the dynamic aperture of the new Brazilian synchrotron light source

Marcondes, Rafael José França, 1987- 03 August 2012 (has links)
Orientador: Eduardo Granado Monteiro da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-19T18:24:03Z (GMT). No. of bitstreams: 1 Marcondes_RafaelJoseFranca_M.pdf: 4781078 bytes, checksum: 963ca375d793021d73e27eaf311966c2 (MD5) Previous issue date: 2012 / Resumo: Um novo anel de armazenamento de elétrons está sendo projetado para a produção de luz síncrotron de alto brilho no Laboratório Nacional de Luz Síncrotron (LNLS), em Campinas. Para atingir um alto brilho, requer-se uma forte focalização do feixe, levando a fortes não-linearidades dos campos magnéticos, o que limita a região de estabilidade do movimento dos elétrons. Neste trabalho, estudamos a dinâmica destas partículas no anel e aplicamos métodos para a otimização da abertura dinâmica / Abstract: A new electron storage ring, Sirius, is being designed for the production of high brightness synchrotron light at the Brazilian Synchrotron Light Laboratory (LNLS), in Campinas. To achieve high brightness, strong focusing of the beam is required, leading to strong non-linearities in the magnetic elds, which limit the region of stable motion of the electrons. In this work we study the dynamics of these particles in the ring and apply methods for the optimisation of the dynamic aperture / Mestrado / Mestre em Física
2

Calculation of coupled bunch effects in the synchrotron light source BESSY VSR

Ruprecht, Martin 29 February 2016 (has links)
Im Rahmen dieser Dissertation wird die Stärke der Multibunch-Instabilität (MBI), die von longitudinalen Dipol-, transversalen Dipol- und Quadrupolschwingungsmoden höherer Ordnung getrieben werden mithilfe von analytischen Rechnungen und Trackingsimulationen in dem Ausbauprojekt BESSY Variable Pulse Length Storage Ring (BESSY VSR) des Helmholtz-Zentrum Berlin für Materialien und Energie GmbH (HZB) untersucht und mit dem vorhanden aktiven Dämpfungssystem verglichen. Algorithmen für Trackingsimulationen werden hergeleitet und eine halbempirische Formel zur Abschätzung der transversalen quadrupolaren MBI wird präsentiert. MBI Studien bilden einen wesentlichen Teil der Beurteilung der BESSY VSR Hohlraumresonatoren und begleiteten und beeinflussten ihren Entwicklungsprozess. Mit Berechnungen auf Grundlage des neusten BESSY VSR Hohlraumresonatormodels kann Strahlstabilität als wahrscheinlich und unabhängig vom Füllmuster angesehen werden. Des weiteren wurden Messungen der MBI an BESSY II und der Metrology Light Source (MLS) der Physikalisch-Technischen Bundesanstalt durchgeführt, bei welcher die longitudinale langreichende Impedanz charakterisiert wurde. Transiente Strahllast wird in dieser Arbeit mit analytischen Formeln und neuen, experimentell überprüften Trackingsimulationen berechnet. Für das Standardfüllmuster von BESSY VSR wurde gezeigt, dass die besondere Konfiguration der Hohlraumresonatorfrequenzen zu einer relativ starken Beeinflussung der langen Elektronenpakete führt. Diese verkürzt das Elektronenpaket und vergrößert die Touschekverluste. / In the scope of this thesis, the strength of coupled bunch instabilities (CBIs) driven by longitudinal monopole higher order modes (HOMs) and transverse dipole and quadrupole HOMs is evaluated for the upgrade project BESSY Variable Pulse Length Storage Ring (BESSY VSR) at Helmholtz-Zentrum Berlin für Materialien und Energie GmbH (HZB), based on analytic calculations and tracking simulations, and compared to the performance of an active bunch-by-bunch feedback (BBFB). Algorithms for tracking codes are derived, and a semi-empirical formula for the estimation of transverse quadrupole CBIs is presented. CBI studies are an integral part of the benchmarking of the cavity models for BESSY VSR and have been accompanying and influencing their entire design process. Based on the BESSY VSR cavity model with highly advanced HOM damping, beam stability is likely to be reached with a BBFB system, independent of the bunch fill pattern. Additionally, measurements of CBIs have been performed at BESSY II and the Metrology Light Source of the Physikalisch-Technische Bundesanstalt (MLS), where the longitudinal long range impedance was characterized. Transient beam loading is evaluated by means of analytic formulas and new experimentally verified tracking codes. For the baseline bunch fill pattern of BESSY VSR, it is shown that the particular setup of cavity frequencies amplifies the transient effect on the long bunch, limiting its elongation and potentially resulting in increased Touschek losses.
3

Two-Dimensional Bunch-Resolved Optical Beam Diagnostics at BESSY II

Koopmans, Marten 05 April 2022 (has links)
BESSY II ist eine Strahlungsquelle der dritten Generation, die vom Helmholtz-Zentrum Berlin für Materialien und Energie GmbH für Experimente mit Synchrotronstrahlung betrieben wird. Mehrere Betriebsmodi werden am BESSY II Speicherring angeboten bzw. entwickelt, um die Anforderungen der vielfältigen Nutzergemeinde zu erfüllen. Dazu gehören nicht nur ein komplexes Füllmuster im Standardnutzerbetrieb, sondern auch spezielle Betriebsmodi mit kurzen Pulsen oder das sogenannte Transverse Resonant Island Buckets Separationsschema. Die Komplexität des Füllmusters erfordert eine pulsaufgelöste Strahldiagnose für die Inbetriebnahme und zur Sicherstellung der langfristigen Qualität des Beschleunigerbetriebs. Ferner werden für den Kurzpulsbetrieb Pulslängenmessungen mit ps Auflösung benötigt. Im Rahmen dieser Arbeit wird zu diesem Zweck eine neue Diagnoseplattform mit mehreren Strahlrohren aufgebaut. Jeweils ein Strahlrohr ist für transversale Strahlgrößenmessungen und für longitudinale Strahldiagnose vorgesehen. Beide Strahlrohre sind mit Messapperaturen für pulsaufgelöste Messungen ausgestattet. Hauptfokus dieser Arbeit liegen auf dem Design, der Installation und den Verbesserungen dieser Strahlrohre und den zugehörigen Meßgeräten in Kombination mit spezifischen Anwendungen in der Strahldiagnose an BESSY II. Im Allgemeinen erfordern Kopplungen zwischen Zeit- und Raumkoordinaten pulsselektive und korrelierte Detektionsmethoden mehrerer Parameter. Daher sind die longitudinale Diagnose sowie die Streak Kamera so optimiert worden, dass die direkte Abbildung des transversalen Strahlprofils möglich ist und sogar interferometrische Strahlgrößenmessungen durchführbar. Zusätzlich zur Zeitachse der Streak Kamera kann entweder die horizontale oder die vertikale Dimension des Strahls abgebildet werden und dadurch sind 2D-Messungen möglich. Mit dieser Methode wurden mehrere pulsaufgelöste 2D-Messungen durchgeführt und Analysemethoden entwickelt. / BESSY II is a third generation light source operated by the Helmholtz-Zentrum Berlin für Materialien und Energie GmbH for experiments with synchrotron radiation. Multiple operation modes are offered or are under development at the BESSY II storage ring to serve the needs of its diverse user community. This does not only include a complex fill pattern in standard operation, but also special operation modes featuring short pulses or the new transverse resonant island buckets separation scheme. The complexity of the fill pattern requires bunch-resolved diagnostics for commissioning and to ensure the long-term quality of accelerator operation. In addition, short pulse operation demands bunch length measurements with ps resolution. For this purpose a new diagnostics platform featuring multiple beamlines is set up. One beamline is dedicated for transverse beam size measurements and one for longitudinal diagnostics. Both beamlines are equipped with fast gated devices for bunch-resolved measurements. Design, installation and improvements of these beamlines and the measuring devices are the main focus of this work, together with specific BESSY II bunch diagnostics applications. In general, coupling between time- and space-coordinates do call for bunch-selective and correlated multi-parameter detection methods. Thus, the longitudinal diagnostics beamline and the streak camera have been made capable of direct transverse beam-profile imaging and even interferometric beam size measurements are feasible. Either the horizontal or vertical beam dimension can be imaged in addition to the time axis of the streak camera and 2D measurements are possible. Taking advantage of these capabilities, multiple bunch-resolved 2D measurements have been performed and analysis methods have been developed.

Page generated in 0.0488 seconds