• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 453
  • 50
  • 47
  • 47
  • 47
  • 32
  • 15
  • 15
  • 14
  • 14
  • 8
  • 1
  • 1
  • Tagged with
  • 468
  • 468
  • 439
  • 332
  • 187
  • 156
  • 127
  • 108
  • 101
  • 91
  • 81
  • 78
  • 73
  • 73
  • 59
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Proposta de um filtro de partículas por reamostragem de importância híbrida para rastreamento visual / Sampling importance hybrid particle filter for visual tracking

Legarda Córdoba, Diego Antonio 01 March 2013 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2013. / Submitted by Alaíde Gonçalves dos Santos (alaide@unb.br) on 2013-09-13T13:33:56Z No. of bitstreams: 1 2013_DiegoAntonioLegardaCordoba.pdf: 39409706 bytes, checksum: 72b54c49ae43f3b93d39b94a83bce0bb (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2013-09-13T15:09:54Z (GMT) No. of bitstreams: 1 2013_DiegoAntonioLegardaCordoba.pdf: 39409706 bytes, checksum: 72b54c49ae43f3b93d39b94a83bce0bb (MD5) / Made available in DSpace on 2013-09-13T15:09:54Z (GMT). No. of bitstreams: 1 2013_DiegoAntonioLegardaCordoba.pdf: 39409706 bytes, checksum: 72b54c49ae43f3b93d39b94a83bce0bb (MD5) / O rastreamento mediante visão computacional constitui um campo de amplo pesquisa tendo em conta todas as aplicações possíveis. Para conseguir um bom desempenho do sistemas de rastreamento, propõem-se algoritmos estocásticos que lidam com problemas do ruido no sistema e na adquisição das observações do entorno. Dentre os métodos estocásticos encontrase o filtro de partículas. Este filtro tem bom desempenho lidando com não-gaussianos, nãolineares, e multi-módulo problemas; quando os objetos rastreados não apresentam oclusões. Neste trabalho propõe-se um filtro de partículas com comportamento inercial que permita obter um comportamento robusto do rastreamento nos casos quando uma oclusão ocorrer mantendo o comportamento dinâmico do objeto, ação alcançada com a estimação da variação da posição ao longo dos frames anteriores à oclusão. Além de tratar as oclusões, o método exibe um ótimo desempenho em sequências com mudanças de iluminação, modificações bruscas de trajetória, com fundo variável e aqueles na qual existem mais de um alvo a rastrear. Os resultados obtidos demostram que o método de rastreamento consegue um melhor desenvolvimento que o filtro padrão nas situações que precisam de um modelo do movimento do objeto a ser rastreado como são as sequências descritas.
12

Contribuição a geologia da região do Alto Rio Negro, utilizando o processamento digital de dados aerogeofisicos e de imagens de radar (RADAMBRASIL, JERS1-SAR)

Filardi, Marcia Cristina Lohmann 03 April 1998 (has links)
Orientador: Elisabete Maria Pascholati / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-07-23T16:47:00Z (GMT). No. of bitstreams: 1 Filardi_MarciaCristinaLohmann_M.pdf: 5047437 bytes, checksum: 68550d4aebf8d0dd51c87e386a2e2e8b (MD5) Previous issue date: 1998 / Resumo: O presente trabalho descreve a utilização de técnicas de processamento digital de dados aerogeofisicos e imagens de radar do JERS 1 - SAR e do Projeto RADAMBRASIL, na região do Alto Rio Negro, no Estado do Amazonas. Os objetivos principais foram os de testar a utilização destas técnicas com o intuito de contribuir com informações geológicas adicionais para o pouco conhecimento que se tem da área de estudo e verificar as vantagens e desvantagens do uso destas técnicas nos diferentes dados empregados em áreas de baixo relevo, densamente florestadas, com um intemperismo atuante e uma geologia bastante monótona, em função da carência de dados. Os produtos! obtidos foram primeiramente analisados individualmente e posteriormente através da sobreposição dos dados. Os resultados mostram que a partir dos dados gamaespectrométricos foi possivel separar na área diferentes dominios radiométricos, enquanto que, os dados magnetométricos contribuiram no sentido de separar dominios magnéticos distintos e definir o padrão tectono-estrutural da região. As imagens de radar não forneceram resultados satisfatórios em função do alto ruido existente e das próprias caracteristicas da área de estudo, já citadas anteriormente; sendo possivel apenas o reconhecimento de feições estruturais a partir desses dados / Abstract: Brazil's northwest upper Rio Negro valley is the geologically least known area of the country. This is mainly due to intense weathering and tropical rain forest cover besides limited access. This work was carried out in order to obtain additional infomation from available remote sensing and aerogeophysical data. Orbital (JER5-1) and air bome (RADAMB RAS I L) SAR data and aerogeophysical (magnetics and gamma-spectrometry) data were processed for obtaining lithological and estructural data. Speckle imposes a severe limit to the use of JERS-1 SAR data. RADAMBRASIL imagery is strongly afected by electronic noise and differential shadowing. Due to that radar imagery was used mainly for extraction of lineaments (fracture traces). Magnetic data yielded deep structural information and regional lithological zoning. Most of lithological information was obtained from gamma-spectrometry data which allowed the separation of different granitic units / Mestrado / Metalogenese / Mestre em Geociências
13

Comparação entre tecnicas morfometricas aplicadas ao epitelio vaginal apos uso prolongado do contraceptivo injetavel acetato de medroxiprogesterona de deposito

Madureira Filho, Jose Augusto Hart 01 August 2018 (has links)
Orientadores : Konradin Metze, Luis Guillermo Bahamondes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-01T03:58:19Z (GMT). No. of bitstreams: 1 MadureiraFilho_JoseAugustoHart_M.pdf: 1195277 bytes, checksum: ad3e104ee55d7d30c1b5e76cb1f4e8d9 (MD5) Previous issue date: 2001 / Resumo: O acetato de medroxiprogesterona de depósito (AMPD) é um contraceptivo de depósito, de absorção lenta, extensamente usado no mundo. Tem sido sugerido que esta droga possa alterar a mucosa vaginal e assim poderia aumentar o risco de transmissão de doenças sexualmente transmissíveis, facilitando, por exemplo, a aquisição do vírus da imunodeficiência humana (HIV). Em experiências com animais, foi mostrado que injeções de AMPD provocavam uma atrofia no epitélio vaginal, ocorrendo um aumento na incidência de infecções pelo vírus da imunodeficiência do símio (SIV). Estudos clínicos são contraditórios. MAUCK et al., (1998) realizaram um estudo prospectivo no qual 16 mulheres submeteram-se à biópsia vaginal depois de três meses da administração de uma dose de AMPD e os resultados mostraram que não houve mudança na espessura do epitélio vaginal. MILLER et al., (2000) mostrou que o número de camadas de células no epitélio estava significativamente reduzido, a espessura epitelial estava diminuída tanto quanto a camada de glicogênio, depois de 6 meses de uso do AMPD, o que poderia prejudicar a barreira epitelial vaginal para infecções. A diferença entre estes dois estudos poderia ser em razão das características individuais de ambos, tais como, escolha das pacientes ou, simplesmente, em virtude dos métodos morfométricos usados. Para tornar claro o último tópico, comparam-se dois métodos diferentes de avaliação morfométrica da espessura do epitélio vaginal de mulheres, depois de uso prolongado de AMPD. Vinte usuárias de 150 mg AMPD, como um método anticoncepcional utilizado durante pelo menos 2 anos e nenhum mais de três anos e 20 não usuárias de qualquer hormônio, foram pareadas para participarem do estudo. Uma biópsia foi coletada a direita ou à esquerda da parede vaginal, fixada em uma solução de formaldeído aquosa a 4% e foi incluída em parafina. Os cortes foram corados com hematoxilina-eosina. A avaliação morfométrica foi feita da seguinte forma: 1) morfometria manual: usando uma ocular milimetrada, tendo os observadores, medidas a menor e a maior espessuras do epitélio, como também as espessuras de três pontos escolhidos ao acaso; 2) morfométrico interativo: Imagens do epitélio vaginal foram digitalizadas pelo sistema KS400. Então uma imagem binária, contrastando o epitélio vaginal, foi selecionada e os valores, menor, maior e três áreas aleatoriamente escolhidas, eram automaticamente determinadas por um algoritmo especial, escrito para este propósito. Para análise final, foi definida a variável 'média final¿ como a média aritmética da maior medida, menor medida e das três medidas aleatórias. Para comparar a qualidade das medidas dos dois métodos calculam-se as distribuições de poder do teste dos dois métodos. O poder do teste é definido como a probabilidade do teste estatístico aplicado detectar diferenças existentes. O poder do teste depende: da diferença a ser detectada, do desvio- padrão das distribuições e do número de elementos por grupo. Os resultados mostraram que as avaliações morfométricas, baseadas em morfometria computadorizada interativa são superiores às avaliações baseadas em avaliação manual, através de ocular milimetrada, em relação ao poder do teste pareado, para o estudo dos grupos. Na nossa comparação entre os dois métodos, baseada na simulação dos valores em ambos os grupos independentes, nós poderíamos mostra-se a superioridade do poder de teste baseado no cálculo feito por morfometria interativa em imagens digitalizadas. Em resumo, estudos baseados em morfometria interativa de imagens digitalizadas podem revelar mais poder do teste e prover resultados mais fidedignos que investigações baseadas em método micrométrico ocular manual / Abstract: Depot medroxyprogesterone acetate (DMPA) is a contraceptive with depot effect widely used in the world. It has been claimed that this drug could change the vaginal mucosa and thus increase the risk of infectious disease transmission for instance of the human - immunodeficiency virus (HIV). In animal experiments it had been shown that DMPA injections thinned the vaginal epithelium and thus enhanced the Simian immunodeficiency virus infection (SIV) clinical studies are contradictory. Other studies, however could I-------------find charges. The difference between these studies might be due to the study design, choose of the patients or, simply due to the morphometric methods used. In order to clarify the last topic we compared two different methods of morphometric evaluation of vaginal epithelium of women after prolonged use of DMPA. Twenty users and 20 paired non-users of 150 mg DMPA as a contraceptive method (for at least 2 years and no more than three years) participated the study. A biopsy was taken was taken, fixed in a 4% aqueous formaldehyde solution, and paraffin-embedded. Routine sections were stained by haematoxylin-eosin. Morphometric evaluation was done in following way: 1) manual morphometry: Using a eye piece graticule in the ocular the observer measured the minimum and maximum thickness of the epithelium, as well as the thickness at three points randomly chooses "at convenience"; 2) Interactive morphometry: Images of the vaginal epithelium were digitalized by the KS400 system. Then a binary image, contrasting the vaginal epithelium, was selected and an algorithm especially written for this purpose determined the values of minimum, maximum and three randomly chosen areas automatically. For the final analysis we defined the variable "final mean" as the arithmetic mean of the sum built up from the minimum value, maximum value and three randomly values of epithelial thickness. In our comparison between the two methods, we could clearly show the superiority of the test power based on the calculus done by interactive morphometry on digitized images. Since in these comparisons the case numbers and the proportions of the differences to be detected were identical, the latter can only be explained by a smaller variability of the measurements, or in other words greater precision of the measurements of an individual case. In summary studies based on interactive morphometry of digitized images may reveal more test power and therefore provide more reliable results than investigations based on manual ocular micrometry / Mestrado / Anatomia Patologica / Mestre em Ciências Médicas
14

Vocoder LPC com quantização vetorial

Martins, José Antônio 13 July 2018 (has links)
Orientador : Fabio Violaro / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-13T23:59:40Z (GMT). No. of bitstreams: 1 Martins_JoseAntonio_M.pdf: 6784204 bytes, checksum: 4e9df50ca8f72e1710d541924b76a67c (MD5) Previous issue date: 1991 / Resumo: Neste trabalho são descritos os princípios do vocoder LPC, sendo mostrados os métodos para cálculo dos parâmetros do mesmo. Também são apresentados os resultados de simulações de vocoders LPC usando quantização escalar, quantização vetorial e interpolação dos parâmetros quantizados. Inicialmente foi projetado um vocoder LPC não quantizado, o qual serviu de padrão para a avaliação dos vocoders quantizados. Usando a quantização escalar dos coeficientes razão log-área foi obtido um vocoder à taxa de 2200 bit /s, assegurando uma boa qualidade e alta inteligibilidade da voz sintetizada. Com o uso da quantização vetorial obteve-se um bom desempenho em taxas da ordem de 1000 bit/s. Essas taxas foram reduzidas em 50% com o uso da interpolação linear, transmitindo apenas os parâmetros dos quadros ímpares. Assim, conseguiu-se vocoders com taxas ao redor de 500 bit/s, apresentando voz sintetizada com degradação em relação aos sistemas anteriores, mas ainda assegurando uma boa inteligibilidade / Abstract: Not informed. / Mestrado / Eletronica e Comunicações / Mestre em Engenharia Elétrica
15

Aumento da profundidade de campo do microscopio otico atraves de processamento digital de imagens

Ciciliato, Vitor 07 April 1995 (has links)
Orientador: Jose Geraldo Chiquito / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica / Made available in DSpace on 2018-07-20T03:38:33Z (GMT). No. of bitstreams: 1 Ciciliato_Vitor_D.pdf: 14147647 bytes, checksum: b52740feb464e2eab2adcd62e8dc0705 (MD5) Previous issue date: 1995 / Resumo: Uma das principais limitações do microscópio óptico é a sua pequena profundidade de campo, que é tão mais grave quanto maior for a resolução empregada. Esta limitação impede, em muitos casos, a obtenção de imagens onde o espécime aparece nítido em todo o campo visual. Este trabalho desenvolve várias técnicas de processamento digital de imagens para aumentar a profundidade de campo de imagens obtidas com o microscópio óptico. As imagens são adquiridas através de uma câmara de vídeo montada, com um adaptador, no tubo da ocular do microscópio. Através da seleção do número de imagens de entrada, o microscopista pode controlar a profundidade de campo na imagem resultante. Foram propostos dois métodos de processamento. O primeiro se baseia num método de enriquecimento de imagens para destacar bordas e formas conhecido por mascaramento não-nítido. O segundo se baseia num processo de ?recorte? e ?colagem? das regiões nítidas das imagens de entrada, sendo a posição do recorte determinada pelas curvas de nitidez destas imagens. Um processo matemático para a reconstrução do espaço-objeto, com a conseqüente eliminação da profundidade de campo, é desenvolvido através do modelamento do sistema óptico formado pela objetiva do microscópio. Determina-se a resposta impulsiva e a função de transferência deste sistema linear variante com o deslocamento... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Not informed. / Doutorado / Doutor em Engenharia Elétrica
16

Emprego da fotografia digital para avaliação da topografia microscópia da pele /

Cordaro, Larissa Marília Chambô. January 2008 (has links)
Orientador: Hélio Amante Miot / Banca: Ediléia Bagatin / Banca: Luciana Patrícia Fernandes Abbade / Resumo: A superfície cutânea é formada por microestruturas poligonais que permitem estimar sua textura e hidratação. A avaliação quantitativa dessa topografia proporciona estimativa da organização e função de estruturas cutâneas, permitindo análise de respostas terapêuticas a intervenções. O uso da fotografia digital microscópica para avaliação do microrelevo superficial pode contribuir para quantificação de aspectos visíveis da pele. Objetivos: Desenvolvimento e validação de sistema fotográfico digital de microscopia de superfície para avaliação quantitativa da topografia microscópica da pele. Métodos: Avaliou-se uma área de 0,25 cm2 de pele dos antebraços de 47 mulheres voluntárias, de fototipos II a IV. As imagens foram coletadas de modo padronizado utilizando-se Câmera Nikon® D70, empregando objetiva macro e lente polarizadora circular acoplados a dermatoscópio sem a lâmina de contato com a pele. Foram realizados experimentos para testar a influência da luminosidade externa, melhor canal de cor e validação da técnica a partir do uso de substância hidratante, avaliação da topografia microscópica da pele em relação à faixa etária e em relação à xerose cutânea sintomática sob tratamento imediato. Não se observou interferência da iluminação externa nas leituras de luminância média e na repetitividade nas medidas de dispersão dos pixels. O modo de cor que representou melhor desempenho quanto à reprodutibilidade e capacidade discriminatória foi o Gray. Os índices de complexidade textural que apresentaram melhor performance quanto à discriminação e reprodutibilidade das Larissa M. Chambô Cordaro Emprego da fotografia digital para avaliação da topografia microscópica da pele 47 amostras foram: Entropia, Ra, Rq e Dimensão fractal. O sistema foi capaz de detectar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The skin surface is composed of fine lines intersecting each other and forming polygons which reflect its texture and hydration. A quantitative assessment of this topography estimates organization and biological functions of skin structure, can help to evaluate effectiveness of products and surgical techniques. Microscopic digital image analysis of the skin surface may be useful to amount the visually perceived skin changes. Purpose: To develop and validate a microscopic digital image analysis system to objectively assess quantitative measurements of skin microtopography. A 0,25cm2 area from 47 voluntary women forearms which skin phototypes was II to IV has been evaluated. Pictures have taken in a standardized way by a Nikon D70 camera, using macro lens and a parallel polarized filter attached to a dermoscopy set without skin contact plate. We have tested influence of external illumination, best color channel, and the technique was validated using a moisturizing substance. Correlation to age has been attempted using validated variables. Cutaneous xerosis treatment has been also estimated. External illumination has not influenced mean luminance and the repetitivity of pixels dispersion measures. Gray channel has represented best reproductiblity and discriminatory characteristics. Entropy, Ra, Rq and Fractal dimension were complexity indexes with best textural performances. The system has been able to detect significative differences between forearms surface topography before and after moisturizing in healthy or xerotic skin patients. There has not been true correlation between validated textural indexes and age. Conclusions: A photographic method to objectively assess microscopic skin topography has been developed and validated to immediate skin moisturizing. A low Larissa M. Chambô Cordaro Emprego da fotografia... (Complete abstract click electronic access below) / Mestre
17

Classificação interativa de imagens orbitais utilizando técnica de projeção multidimensional de dados /

Aguiar, Tiago Oyan January 2019 (has links)
Orientador: Erivaldo Antônio da Silva / Resumo: A extração de informação por meio do uso de imagens digitais orbitais é de grande importância para diversas áreas do conhecimento. Deste modo, essa pesquisa visa classificar imagens orbitais de alta resolução espacial, utilizando índices espectrais e a técnica de projeção multidimensional de dados Local Affine Multidimensional Projection (LAMP). Embora técnicas de projeções multidimensionais têm sido utilizadas com sucesso em grande conjunto de aplicações na área de visualização de dados, estas, por sua vez, não têm sido exploradas no contexto de cartografia. Observando esta lacuna, foi desenvolvido um método, no contexto da Cartografia e Geociências, a partir do uso e manipulação da técnica LAMP, em uma imagem orbital do satélite QuickBird, com a finalidade de apresentar à comunidade cartográfica e empresas interessadas, novas possibilidades de desenvolvimento de atualizações de bases cartográficas. É valido destacar os benefícios da técnica mencionada, principalmente para suprimir uma demanda cada vez mais recorrente no Sensoriamento Remoto, ligada ao aumento das resoluções espectrais e espaciais e consequente aumento do volume de dados para processamento, que, com o auxílio da técnica LAMP, podem ser manipulados e processados de forma adequada. Assim, mostra-se que a referida técnica, quando aliada a outras abordagens clássicas da área de Geociências, atinge um bom nível de classificação em imagens aéreas, definindo adequadamente as áreas de vegetação e solo exposto. Como ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The extraction of information by using orbital digital images is of great importance for several areas of knowledge. Thus, this research aims to classify orbital images of high spatial resolution, using spectral indexes and the technique of multidimensional data projection site Affine Multidimensional Projection (LAMP). Although, multi-dimensional projection techniques have been successfully used in a large set of applications in the field of data visualization, however, have not been explored in the context of cartography. Observing this gap, a method was developed in the context of cartography and geosciences, from the use and manipulation of the LAMP technique, in an orbital image of the QuickBird satellite, to present to the cartographic community and companies new possibilities for the development of cartographic bases updates. It is worth highlighting the benefits of the aforementioned technique, mainly to suppress an increasingly recurrent demand in remote sensing, linked to the increase of spectral and spatial resolutions and consequent increase in the volume of data for processing, which, with the aid of the LAMP technique, can be manipulated and processed appropriately. Thus, it is shown that the aforementioned technique, when allied to other classical approaches in the area of geosciences, achieves a good level of classification in aerial images, appropriately defining the areas of vegetation and exposed soil. As a research product, a vegetation classification map ... (Complete abstract click electronic access below) / Mestre
18

Fractografia quantitativa : relações entre tenacidade e o comportamento fractal em ligas metálicas /

Caltabiano, Pietro Carelli Reis de Oliveira. January 2011 (has links)
Orientador: Luis Rogério de Oliveira Hein / Banca: Alfeu Saraiva Ramos / Banca: Miriam de Lourdes N. Motta Melo / Resumo:Superfícies de fratura expressam a sequência de eventos de liberação de energia coma propagação de trincas. No caso de ligas metálicas, a evolução das formações topográficas pode indicar as linhas de ação de carga, falhas de uso ou de processamento e outros. Nestes casos, a fractografia pode auxiliar na investigação de falhas estruturais e nos processos de manufatura. Neste trabalho foram realizados dois tipos de análise de correlações: a primeira entre a largura da zona deestiramento (LZE) e o valor da tenacidade a fratura (Kc) e a segunda entre os valores de tenacidade à fratura e a fractalidade da topografia das superfícies fraturadas, sempre por meio de processamento digital de imagens. Para obtenção das superfícies de fratura dos corpos de provas do aço 15-5PH e da liga do alumínio AA 7475, este foram ensaiados para obtenção de valores de Kic. As superfícies de fratura geradas foram mapeadas pela técnica de reconstrução por extensão de foco, e para cada região foram calculados os valores de dimensão fractal: dimensão monofractal (Df), dimensão estrutural (Ds) e dimensão textural (DT). Os resultados da análise entre LZE e Kc apresentaram uma alta correlação para o aço 15-5PH, mostrando a validade do método de seleção da LZE o do processo de reconstrução da imagem. Já análise fractal mostrou quanto maior a ductilidade do material menor é o nível de correlação linear obtido entre tenacidade e os valores fractais. Contudo, para o aço 15-5PH, com comportamento transitando entre o regime linear elástico e elasto-plástico, o nível da correlação linear entre Kc e os valores fractais tende a ser significante, principalmente para as correlações estabelecidas envolvendo a dimensão textural (DT). Devido ao caráte dúctil da liga AA 7475 não foram encontrados correlações significantes / Abstract: Fracture surface express the sequence of energy release events during crack propagation and, in the case of metallic alloys, the topographic evolution can descrbr the action of load lines, failures due to using processing, and others. In the cases, the quantitative fractography can help the investigation of failures in structures and manufacturing processes. In this work, two correlation analyses were carried out: the first between the stretch zone width (SZW) and fracture toughness (Kc) and the second between Kc and the fractality of the fractured surface topography, both analyzed by digital image processing. The 15-5PH stee and AA7475 aluminium alloy fracture surfaces for analysis were obtained by toughness testing. Each seurface was mapped by extend depth of field technique, and the following fractal dimension values were calculated for each mapped position: monofractal dimension (Df), structural dimension (Ds) and textural dimension (DT). The results for analysis between LZE and Kc data showed a high correlation for 15-5PH steel, also checking the validity of the delimitation method of SZW and the image reconstruction process. The fractal analysis showed that as higher the ductility of the material, as lower will be the level of linear correlation obtained between toughness and the fractal values. However, for 15-5PH steel, with behavior ranging between the linear-elastic and elastic-plastic, the level of linear correlation between Kc and the fractal values tend to be significant, especially for established correlations involving the textural dimension (Dt). However, for AA 7475 aluminium alloy no significant correlation could be established due to predominance of shallow dimples / Mestre
19

Método de superfícies ativas usando local binary patterns (LBP) aplicado na segmentação de lobos pulmonares em imagens de tomografia computadorizada do tórax

Cavalcante, Tarique da Silveira 21 March 2016 (has links)
CAVALCANTE, T. S. Método de superfícies ativas usando local binary patterns (LBP) aplicado na segmentação de lobos pulmonares em imagens de tomografia computadorizada do tórax. 2016. 181 f. Tese (Doutorado em Engenharia de Teleinformática) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-09-13T17:02:51Z No. of bitstreams: 1 2016_Tese_tscavalcante.pdf: 12172675 bytes, checksum: a4f69559319313702095b478de3a549d (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-09-13T17:09:11Z (GMT) No. of bitstreams: 1 2016_Tese_tscavalcante.pdf: 12172675 bytes, checksum: a4f69559319313702095b478de3a549d (MD5) / Made available in DSpace on 2016-09-13T17:09:11Z (GMT). No. of bitstreams: 1 2016_Tese_tscavalcante.pdf: 12172675 bytes, checksum: a4f69559319313702095b478de3a549d (MD5) Previous issue date: 2016-03-21 / In several applications involving medical image analysis, the process of image segmentation, be it automatic or manual, is a present task. An accurate segmentation provides information for inspection of anatomical structures, to identify diseases and monitoring of its progress, and even for surgical planning and simulation. Thus, the role of image segmentation is essential in any medical image analysis system. Among the segmentation techniques in the literature, the active models technique is one of the most popular approaches of the last two decades and has been widely used in medical image segmentation, achieving considerable success. Active models that are applied on three-dimensional applications are called Active Surfaces Methods (ASM), which has been widely used in the segmentation of 3D objects, evolving under the influence of their energy to converge to the desired surface. So, knowing how essential surface extraction is to obtain an accurate segmentation, this thesis conducts a study on ASM, identifying its advantages and limitations, and proposes a new ASM to the segmentation of pulmonary lobes on CT images. The new ASM has as contributions internal forces for unstructured meshes, external energies based on LBP texture and Hessian matrix, and automatic initialization for each lobe. In order to validate this proposal, a comparative study of the performance of the internal forces in synthetic images, along with the comparison of the segmentation of lung lobes obtained by the proposed method with the segmentation of a gold standard carried out by an expert medical board will be conducted. The results show that the internal forces performs well, providing synthetic images segmentation with average distance of less than 1 voxel and adjustment measures of 0.95. The automatic initialization has also achieved significant results, with overall hit rate of 94%. Finally, the rates obtained for pulmonary lobe segmentation allows validation of the proposed method with average distance values of 1.93 mm and rates of size and form adjustment of 0.98 and 0.89, respectively. Thus, it is concluded that the obtained metric is sufficient to validate the lobar segmentation obtained in this thesis / Em diversas aplica¸c˜oes de an´alise de imagens m´edicas, o processo de segmenta¸c˜ao de imagens, seja autom´atico ou manual, ´e uma tarefa presente. Uma segmenta¸c˜ao correta fornece informa¸c˜oes para inspe¸c˜ao de estruturas anatˆomicas, para a identifica¸c˜ao de doen¸cas e acompanhamento de seu progresso e at´e mesmo para o planejamento cir´urgico e simula¸c˜ao. Logo, o papel da segmenta¸c˜ao de imagens ´e essencial em qualquer sistema de an´alise de imagens m´edicas. Dentre as t´ecnicas de segmenta¸c˜ao presentes na literatura, a t´ecnica de modelos ativos ´e uma das abordagens mais populares durante as duas ´ultimas d´ecadas e tem sido amplamente utilizada em segmenta¸c˜ao de imagens m´edicas, obtendo um sucesso consider´avel. Os modelos ativos que atuam em aplica¸c˜oes tridimensionais s˜ao denominados de M´etodos de Superf´ıcies Ativas (MSA), que por sua vez tˆem sido bastante utilizados na segmenta¸c˜ao de objetos 3D, evoluindo sob a influˆencia de suas energias at´e convergir para a superf´ıcie desejada. Neste sentido, tendo em vista que a extra¸c˜ao de superf´ıcie ´e essencial para a obten¸c˜ao de uma correta segmenta¸c˜ao, a presente tese realiza um estudo sobre MSA, identificando suas vantagens e limita¸c˜oes, e prop˜oe um novo MSA para a segmenta¸c˜ao de lobos pulmonares em imagens de TC. Esta novo MSA tem como contribui¸c˜oes for¸cas internas para malhas n˜ao estruturadas, energias externas baseadas em textura LBP e matriz Hessiana, al´em de inicializa¸c˜ao autom´atica por lobo pulmonar. Para validar a proposta ´e realizado um estudo comparativo da atua¸c˜ao das for¸cas internas em imagens sint´eticas, al´em da compara¸c˜ao da segmenta¸c˜ao dos lobos pulmonares obtida pelo m´etodo proposto com a segmenta¸c˜ao de um padr˜ao ouro realizado por uma junta m´edica especialista. Os resultados comprovam que as for¸cas internas apresentam bom desempenho na segmenta¸c˜ao de imagens sint´eticas com valores de distˆancia m´edia menores que 1 voxel e com medidas de ajuste maiores do que 0,95. A inicializa¸c˜ao autom´atica tamb´em obteve resultados relevantes, com taxa de acerto geral igual a 94%. Por fim, os valores obtidos para a segmenta¸c˜ao dos lobos pulmonares permitem validar o m´etodo proposto com valores de distˆancia m´edia igual a 1,93 mm e valores de ajuste de tamanho e de forma de 0,98 e 0,89, respectivamente. Neste contexto, conclui-se que as m´etricas apresentadas neste trabalho s˜ao suficientes para validar a segmenta¸c˜ao lobar obtida nesta tese
20

Contornos ativos geométricos e paramétricos aplicados à segmentação do ventrículo esquerdo em imagens de ecocardiograma / Geometric and parametric active contours methods applied on left ventricle segmentation in echocardiography images

Mesquita, Vitor Alencar de 12 1900 (has links)
MESQUITA, V. A. Contornos ativos geométricos e paramétricos aplicados à segmentação do ventrículo esquerdo em imagens de ecocardiograma. 2012. 93 f. Dissertação (Mestrado em Engenharia de Teleinformática) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2013-06-17T12:44:24Z No. of bitstreams: 1 2012_dis_vamesquita.pdf: 9203497 bytes, checksum: bdc9f34a52161d5491dbbadf49657933 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2013-06-17T16:19:35Z (GMT) No. of bitstreams: 1 2012_dis_vamesquita.pdf: 9203497 bytes, checksum: bdc9f34a52161d5491dbbadf49657933 (MD5) / Made available in DSpace on 2013-06-17T16:19:35Z (GMT). No. of bitstreams: 1 2012_dis_vamesquita.pdf: 9203497 bytes, checksum: bdc9f34a52161d5491dbbadf49657933 (MD5) Previous issue date: 2012-12 / The correct left ventricle identi cation in echocardiography images constitutes an im- portant tool to early diagnosis of heart diseases. However, limitations inherent to the im- age acquisition process, as low signal-to-noise ratio and presence acoustic shadows, make this identi cation a complex task. In this work, purposing to segment the left ventricle, geometric and parametric active contours are applied over echocardiography images. A new parametric active contours variation, the algebraic active contours method, and two kinds of level-set methods, one based on gradient and another based on regions, are tested and compared. In this work, four contributions to literature are proposed. One is the Hamiltonian ltering by a gaussian window in order to accelerate the contour movement. Another one is a signal function, that allows the contour to change automatically its ra- dial direction. Moreover, the algebraic active contours method conception itself is one of the contributions. Finally, the last one is the contours map superposition, that increases active contour's in uence area without accuracy loss. It is concluded that, although the geometric active contours capacity of splitting and merging itself independently of new parametrizations, the algebraic active contours method is, among the evaluated methods, the only one able to segment the left ventricle in echocardiography images conform to the gold-stardard provided by the specialists. / A identificação correta do ventrículo esquerdo em imagens de ecocardiograma constitui uma importante ferramenta no auxílio ao diagnóstico precoce de doenças cardiovasculares. No entanto, limitações inerentes ao processo de aquisição das imagens, como baixa relação sinal-ruído e presença de sombras acústicas, tornam essa identificação uma tarefa complexa. Neste trabalho, com o objetivo de segmentar o ventrículo esquerdo, contornos ativos geométricos e paramétricos são aplicados sobre imagens de ecocardiografia. Uma nova variação dos contornos ativos paramétricos, o método dos contornos ativos algébricos, e duas modalidades de método level-set, uma baseada no gradiente e outra baseada em regiões, são testadas e comparadas. São propostas, neste trabalho, quatro contribuições à literatura. Uma é a filtragem do Hamiltoniano por uma janela gaussiana a afim de acelerar o movimento do contorno. Outra é uma função sinal, que permite que o contorno mude sua direção radial automaticamente. Além disso, a própria concepção do método dos contornos ativos algébricos é uma das contribuições. Finalmente, a ultima é a superposição de mapas de contorno, que aumenta a área de influência do contorno ativo sem perda de precisão. Conclui-se que, apesar da capacidade dos contornos ativos geométricos de dividirem-se e unificarem-se independentemente de novas parametrizações, o método dos contornos ativos algébricos é, dentre os avaliados, o único capaz de realizar a segmentação do ventrículo esquerdo nas imagens de ecocardiografia conforme o padrão-ouro fornecido pelos especialistas.

Page generated in 0.067 seconds