• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 19
  • 2
  • 1
  • Tagged with
  • 66
  • 66
  • 36
  • 26
  • 18
  • 18
  • 15
  • 12
  • 10
  • 9
  • 9
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Implementacao da irradiacao de corpo inteiro em radioterapia / Implementation of total body irradiation in radiotherapy

HABITZREUTER, ANGELA B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:05Z (GMT). No. of bitstreams: 0 / Ao implementar uma técnica de tratamento, as características do feixe nas condições de irradiação precisam ser bem conhecidas e estudadas. Cada um dos parâmetros utilizados para cálculo de dose deve ser medido e validado antes da utilização dos mesmos na rotina clínica. Isso se torna ainda mais necessário quando se tratam de técnicas especiais. Neste trabalho estão descritos todos os parâmetros e medidas necessárias para a implementação da irradiação de corpo inteiro numa instalação projetada para tratamentos convencionais, e que faz uso de geometrias não convencionais para gerar os tamanhos de campos alargados. Além disso, são apresentados os dados de comissionamento desta modalidade no Hospital das Clínicas de São Paulo utilizando a comparação de três tipos de detectores para medidas de dose de entrada durante tratamentos de irradiação de corpo inteiro. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
22

Aplicação das técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) na determinação de curvas de isodose em uma simulação de tratamento de câncer pela técnica de radioterapia em arco modulado volumétrico – VMAT / Application of the thermoluminescent (TL) and optically stimulated luminescence (OSL) dosimetry techniques to determinate the isodose curves in a cancer treatment planning simulation using volumetric modulated arc therapy - VMAT

BRAVIM, AMANDA 02 September 2015 (has links)
Submitted by Maria Eneide de Souza Araujo (mearaujo@ipen.br) on 2015-09-02T12:47:25Z No. of bitstreams: 0 / Made available in DSpace on 2015-09-02T12:47:25Z (GMT). No. of bitstreams: 0 / A Radioterapia em Arco Modulado Volumétrico (VMAT) é uma técnica avançada de Radioterapia de Intensidade Modulada (IMRT). Esse avanço na técnica é devido à rotação contínua do gantry juntamente com a modulação do feixe de radiação proporcionando um tempo menor no tratamento do paciente. O objetivo desse trabalho é a verificação de curvas de isodose em uma simulação de um tratamento de vértebra com proteção de medula espinhal utilizando as técnicas de dosimetria termoluminescente (TL) e luminescência opticamente estimulada (OSL) e os dosímetros de LiF:Mg,Ti (TLD-100), CaSO4:Dy e Al2O3:C e microdosímetros de LiF:Mg,Ti (TLD-100). Os dosímetros foram caracterizados com a utilização de placas de PMMA de 30x30 cm2 e diversas espessuras. Todas as irradiações foram feitas utilizando o acelerador linear Truebeam STx da Varian do Hospital Israelita Albert Einstein, com feixe de fótons de 6 MV. Após a caracterização dos dosímetros, os mesmos foram irradiados seguindo a simulação do planejamento escolhido e utilizando um objeto simulador de PMMA produzido para medidas de VMAT. Essa irradiação teve como finalidade verificar através das duas técnicas de dosimetria as curvas de isodose dessa simulação de tratamento. Todos os tipos de dosímetros apresentaram resultados satisfatórios na verificação das curvas de isodose utilizando ambas as técnicas de dosimetria. Porém, analisando a complexidade das curvas de isodose e a possibilidade das curvas estarem muito próximas, o microdosímetro de LiF:Mg,Ti se mostrou o mais apropriado para o uso devido à suas pequenas dimensões. Em relação à melhor técnica, como ambas apresentaram resultados satisfatórios, a técnica TL é a que apresenta menor complexidade em ser utilizada, pois a maioria dos Departamentos de Radioterapia já possuem um Laboratório para leitura TL. A técnica OSL exige mais cuidados e maior investimento do Departamento. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
23

Large scale entrance surface dose survey and organ dose measurements during diagnostic radiology using the Harshaw 5500 and 6600 TLD systems

Broadhead, Dawn January 2001 (has links)
No description available.
24

Um estudo da técnica de dosimetria com TLDs e sua aplicação em feixes de kilovoltagem / A study of the dosimetry technique with TLDs and its application in kilovoltage beams

Yaly, Carolina Cariolatto 08 June 2018 (has links)
Em radioterapia a entrega de doses deve apresentar incerteza máxima de 5%. Para isso, realiza-se o controle de qualidade dos equipamentos usados. Para feixes de raios X de kilovoltagem (kV), a câmara de ionização (CI) de ar-livre é instrumento de referência para determinar o kerma no ar. Na prática clínica, são usadas CIs de placas paralelas, dependendo da energia dos feixes. Segundo o TRS-398, as CIs usadas nestes feixes deveriam ser calibradas em dose absorvida na água, no entanto, no Brasil ainda não há um método implantado para este tipo de calibração. Para agravar a situação, atualmente, não se tem também disponíveis no Brasil serviços de calibração para CI em kerma no ar ou exposição nesta faixa de energia e muitos serviços ainda utilizam feixes kV, com a sua dosimetria mantida pelas condições disponíveis em cada serviço. Essa pesquisa tem o objetivo de estudar a resposta do TLD quando irradiado com feixes de kV, a fim de obter uma alternativa dosimétrica para verificações de doses nestes feixes. Utilizamos dois grupos com 100 TLDs, que foram calibrados por uma fonte de Césio-137. Quatro equipamentos diferentes de raios X de kV foram usados para levantamento de curvas relacionando as doses lidas pelos TLDs e as doses calculadas pela dosimetria de cada equipamento. Para o estudo da dependência energética, realizamos correções nas medidas utilizando três diferentes métodos. Após observarmos que os fatores de correção da dependência energética variam quando comparados entre si, calculamos o valor médio desses fatores e os utilizamos como fator de correção ótimo, obtendo variações médias de -2,8% entre as doses entregues em comparação com as doses lidas, sendo a máxima variação 17% e a mínima variação -23% entre os equipamentos. / In radiotherapy the doses must be delivered with a maximum deviation of 5% in comparison to those planned. Therefore, it\'s necessary to ensure the quality of the equipment used. For kilovoltage (kV) X-rays beams the dosimetry standard reference instrument is a free-air ionization chamber (IC). In usual clinical procedures, plane-parallel IC are used, depending on the beam\'s energy. The TRS-398 says that the ionization chambers used for those beam should be calibrated in absorbed dose to water; nevertheless there is not a method for such a calibration in Brazil. Nowadays, there isn\'t even an available IC calibration service in air kerma or exposure in this range of energy in the country, a lot of services in Brazil still make good use of kV radiation therapy and its dosimetry is limited by the local available conditions. This research\'s goal is to study the thermoluminescent dosimeter (TLD) response when irradiated by kV beams to come up with a dosimetric alternative for the verification of absorbed doses for those beams. We have used two groups composed by 100 TLDs each, whose calibration was done using a source of Cesium-137. Four different kV X-rays equipments were used to create the curves showing the relation between TLDs response and the actual doses calculated by the dosimetry used for each equipment. Three different methods were used to study the dosimeters energetic dependency. After we noticed that the factors obtained using each method were considerably different from each other in the same group, we calculated the mean values of these groups of factors and we set the mean values as an optimal correction factor. We obtained mean deviations of -2.8% among the doses delivered in comparison to the TLDs doses responses - the maximum deviation was 17% and the minimum was -23% among the equipaments tested.
25

Estudo da deposição de dose para diferentes configurações de sementes oncoseed 6711

Lucas Crusoé Tomaz 19 April 2013 (has links)
Nenhuma / O câncer de próstata é o segundo mais ocorrente entre os homens. A braquiterapia com a utilização de sementes de iodo-125 se apresenta como uma das formas de tratamento. Na terapia do câncer de próstata são utilizadas de 80 a 120 sementes de iodo-125 que são implantadas no órgão seguindo um planejamento. Durante o posicionamento e com o passar do tempo, as sementes implantadas sofrem pequenos deslocamentos em relação à posição inicialmente planejada. Estes deslocamentos podem causar diferenças na deposição de dose no volume tumoral. Este trabalho fez um estudo de dosimetria de sementes de iodo-125 utilizadas em braquiterapia de baixa taxa de dose. Na primeira etapa do trabalho, foi realizado o levantamento dos parâmetros dosimétricos da semente seguindo as recomendações do protocolo TG-43 com o objetivo de validar a metodologia. Em seguida, foi realizado um estudo quantitativo da variação na distribuição de dose para três configurações de quatro sementes Oncoseed 6711, sendo duas delas com as quatro sementes em posições simétricas e uma com as sementes apresentando pequenos deslocamentos. Utilizou-se um objeto simulador de tecido mole e dosímetros TLD. Em seguida, um estudo qualitativo das isodoses geradas pelas configurações foi realizado utilizando-se filme radiocrômico, modelo Gafchromic. Este método foi utilizado a fim de complementar o estudo realizado com os cristais. Os parâmetros dosimétricos da semente levantados neste trabalho apresentaram excelente concordância com os valores consensuais do TG -43, validando assim, a metodologia empregada nesta pesquisa. Finalmente, os resultados obtidos com filmes radiocrômicos e dosímetros termoluminescentes mostraram que existe uma diferença significativa na distribuição de dose quando há modificação de posicionamento entre as sementes. A utilização destes dois métodos simultaneamente se mostrou eficiente uma vez que os cristais trazem uma visão pontual e o filme traz uma visão global da distribuição de dose. / Prostate cancer is the second most common cancer among men. Iodine-125 brachytherapy seeds are presented as a form of treatment. In prostate cancer therapy 80-120 iodine-125 seeds are implanted in the organ following a previous planning. During positioning and after it, the implanted seeds can undergo slight displacements relative to the original position. These deviations may cause changes in dose distribution in the tumor volume. This work has made a dosimetry study for iodine-125 seeds used in low dose rate brachytherapy. In the first stage, we performed a one seed dosimetric parameters study following the TG-43 protocol recommendations with the objective of validating our methodology. Then a quantitative study of the variation in dose distribution for three configurations of four seeds OncoSeed 6711 was conducted with two configurations using the seeds in symmetrical positions and the other presenting small displacements. A soft tissue phantom and TLD dosimeters were used. Then a qualitative study of isodose curves of the configurations was performed using radiochromic film, Gafchromic model. This method was used to complement the study of the crystals. The seeds dosimetric parameters obtained in this work showed excellent agreement with the TG-43 consensual values, thus validating the methodology used in this work. The results obtained with radiochromic film and thermoluminescent dosimeters have shown that there is a significant difference in dose distribution when there is a change in the positioning of the seeds. The use of these two methods simultaneously is efficient since the crystals bring a point view and the film has a global view of the dose distribution
26

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fóton / Methods for implementation of in vivo dosimetry (entrance dose) using thermoluminescent dosimeters during radiotherapy treatment with photon beam

Barsanelli, Cristiane 23 November 2006 (has links)
Neste trabalho, estão descritos os métodos de seleção, calibração e de determinação dos fatores de correção, as características físicas dos dosímetros termoluminescentes, o procedimento de cálculo para converter a leitura do dosímetro em dose absorvida e a metodologia para se determinar a dose de entrada. Foram investigadas a praticidade e a utilidade das medidas de dose de entrada com os dosímetros termoluminescentes, bem como a exatidão e a reprodutibilidade no fornecimento da dose diária. As medidas de dose de entrada foram realizadas em cinco pacientes com diagnóstico de câncer de mama tratadas com um feixe de fótons de 6 MV. Não foram detectados grandes desvios entre a dose medida e a dose esperada (os valores concordaram em ± 5%), devido à excelente estabilidade do equipamento de tratamento, ao sistema automático de verificação e à boa exatidão no ajuste diário do tratamento. Uma boa precisão pode ser alcançada quando os fatores de correção para cada parâmetro de influência na resposta do dosímetro são cuidadosamente determinados e aplicados para converter o sinal termoluminescente em dose absorvida. O estudo demonstrou a viabilidade do uso dos dosímetros termoluminescentes para a dosimetria in vivo e sua utilidade como parte de um programa de garantia de qualidade em um serviço de radioterapia. / Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service.
27

Implementação de um sistema dosimétrico termoluminescente para utilização em dosimetria in vivo em teleterapia com feixes de fótons de energia alta / Implementation of a thermoluminescent dosimetric system for use in in vivo dosimetry on radiotherapy with external high energy photon beams

Santos, Lindomar Soares dos 15 October 2007 (has links)
A dosimetria in vivo é a verificação final da dose real administrada ao paciente e tornou-se atualmente necessária devido ao aumento da complexidade e da sofisticaçã das técnicas radioterápicas. A finalidade deste trabalho foi apresentar, verificar e avaliar alguns procedimentos básicos, práticos e viáveis para a implementação da dosimetria in vivo com dosímetros termoluminescentes na verificação de dose em um serviço de radioterapia. Para o estabelecimento do sistema dosimétrico termoluminescente, alguns testes e medições foram realizados, incluindo o procedimento de inicialização, a determinação da homogeneidade do grupo de dosímetros, a determinação do fator de correção individual de cada dosímetro, a determinação da faixa de linearidade do sistema e do coeficiente de calibração. Medições em um objeto simulador antropomórfico foram realizadas para garantir que os métodos utilizados são satisfatórios antes que estes fossem usados para medições em pacientes. Medições de dose em um paciente foram feitas em um tratamento de câncer de próstata. A metodologia proposta pode ser usada como parte de um programa de garantia de qualidade em um serviço de radioterapia. / In vivo dosimetry is the ultimate check of the actual dose delivered to an individual patient and has become a procedure actually necessary due to increasing complexity and sophistication of radiotherapy techniques. The purpose of the present work was to present, verify and evaluate some basic, practical and viable procedures for the implementation of in vivo dosimetry with thermoluminescent dosimeters for patient dose verification at a radiotherapy service. For the setting up of the thermoluminescent dosimetric system, several tests and measurements were carried out including the initialisation procedure, the determination of the batch homogeneity, the determination of individual correction factor of each dosimeter, the determination of linearity range of the system and its calibration coefficients. Anthropomorphic phantom measurements were taken to ensure that the methods are satisfactory before they are used for patients measurements. Patient dose measurements were carried out in a prostate cancer treatment. The proposed methodology can be used as a part of a quality assurance program in a radiotherapy service.
28

Métodos para implementação da dosimetria in vivo (dose de entrada) com dosímetros termoluminescentes na radioterapia externa com feixe de fóton / Methods for implementation of in vivo dosimetry (entrance dose) using thermoluminescent dosimeters during radiotherapy treatment with photon beam

Cristiane Barsanelli 23 November 2006 (has links)
Neste trabalho, estão descritos os métodos de seleção, calibração e de determinação dos fatores de correção, as características físicas dos dosímetros termoluminescentes, o procedimento de cálculo para converter a leitura do dosímetro em dose absorvida e a metodologia para se determinar a dose de entrada. Foram investigadas a praticidade e a utilidade das medidas de dose de entrada com os dosímetros termoluminescentes, bem como a exatidão e a reprodutibilidade no fornecimento da dose diária. As medidas de dose de entrada foram realizadas em cinco pacientes com diagnóstico de câncer de mama tratadas com um feixe de fótons de 6 MV. Não foram detectados grandes desvios entre a dose medida e a dose esperada (os valores concordaram em ± 5%), devido à excelente estabilidade do equipamento de tratamento, ao sistema automático de verificação e à boa exatidão no ajuste diário do tratamento. Uma boa precisão pode ser alcançada quando os fatores de correção para cada parâmetro de influência na resposta do dosímetro são cuidadosamente determinados e aplicados para converter o sinal termoluminescente em dose absorvida. O estudo demonstrou a viabilidade do uso dos dosímetros termoluminescentes para a dosimetria in vivo e sua utilidade como parte de um programa de garantia de qualidade em um serviço de radioterapia. / Selection, calibration procedure to convert TLD signal into absorbed dose and physical characteristics at the thermoluminescent dosimeters, as well as the determination of correction factors and the methodology to determine expected entrance dose, are described in this work. Practical aspects and the utility of entrance dose measures with thermoluminescent dosimeters were investigated, as well as the exactness and the reproducibility of the daily dose release. The entrance dose measures were performed in five patients with diagnosis of breast cancer treated with a 6 MV photon beam. The measured dose and the expected dose values agreed in ± 5%, due to excellent treatment equipment stability, to automatic verification system and the good exactness in the daily treatment adjustment. Good precision can be achieved when the correction factors for each parameter of influence in the dosimeter response are carefully determined and applied to convert the thermoluminescent signal into absorbed dose. The study demonstrates the viability of thermoluminescent dosimeters use for in vivo dosimetry and its utility as part of a quality assurance program in a radiation therapy service.
29

Investigation of dosimetric characteristics of the high sensitivity LiF : Mg,Cu,P thermoluminescent dosemeter and its applications in diagnostic radiology

Fung, Karl Ka Lok January 2000 (has links)
No description available.
30

Projeto, construção e caracterização de um dosímetro para radiação de nêutrons

SOUTO, EDUARDO de B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:56Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0325 seconds