Spelling suggestions: "subject:"telecommunication power supply"" "subject:"elecommunication power supply""
1 |
Current source converters for extraction of power from HVAC linesJanse van Rensburg, Johannes Frederik 11 1900 (has links)
Thesis (D. Tech. Engineering : Electrical ; Dept. Applied Electronics and Electronic Communications) -- Vaal University of Technology / Two methods to convert an AC current source to an AC voltage source are presented.
Both methods make use of a current transformer to provide energy extraction from
the main system while maintaining galvanic isolation between the main system and
the output system. Control is via a pulse width modulation scheme in both instances.
The ftrst method uses a storage element to provide a DC voltage, which feeds an
inverter that supplies the AC load with a voltage source. The second method does
not use a storage element but is a direct AC current source to AC voltage source
converter employing a current transformer. This has not been done before.
A possible application of this study is in the extraction of power from high voltage
transmission lines without the conventional substation and rural grid to supply small
users such as the telecommunication industry.
|
2 |
Design and development of a direct methanol fuel cell for telecommunicationsJoubert, Hardus 06 1900 (has links)
The demand for higher efficiency and cleaner power sources increases daily. The Direct Methanol Fuel Cells (DMFC) is one of those power sources that produces reliable electrical energy at high efficiencies and very low pollution levels. Remote
telecommunication sites need power sources that can deliver reliable power.
This dissertation informs the reader about the working principles of the DMFC and
the materials it consists of. A good amount of theoretical background is also given
on the DMFC, especially on the Membrane Electrode Assembly (MEA). Different
membranes as well as their properties are discussed. Results from other researchers
on DMFCs are also captured. A DMFC stack including a test rig, was built. The DMFC stack consisted of five single DMFC cells. Each cell contained an MEA, Gas Diffusion Layers (GDLS), highly corrosive resistant metal support grids, bipolar flow field plates and end plates. The DMFC stack was operated and tested in a test rig. The test rig held the air blower which supplied the cathode with the required oxidant (air), and the methanol solution tank plus its liquid pump. The liquid pump circulated the
methanol solution through the anode side of the stack.
It was observed that the DMFC is very susceptible to corrosion, especially if the
methanol solution becomes conductive owing to solubility of C02 in it. Methanol itself is a corrosive substance. However the results obtained from the experiments clearly indicate that the DMFC can be implemented as an electrical power source for
telecommunications.
|
Page generated in 0.1425 seconds