• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • 18
  • 17
  • 8
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 114
  • 114
  • 97
  • 27
  • 19
  • 19
  • 17
  • 15
  • 12
  • 12
  • 12
  • 11
  • 11
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Snížení nákladů na výrobu odlitku litého tlakovým litím pomocí aplikace vysokoteplotního separátoru / Cost reduction of a diecast casting by means of high temperature separator

Koplík, Jiří January 2017 (has links)
The diploma thesis is focuses on new technology in of high pressure die casting industry. Attention is paid in particular to heating, cooling and the influence of the die lubricants on the quality of castings. theoretical knowledge was applied in practise. The optimization of the production cycle was carried out using a high temperature die lubricant and subsequent evaluation on particular casts in foundry KOVOLIT Modřice a.s.
112

Člověk jako faktor kvality vzduchu / Air quality in buildings

Kops, Tomáš January 2019 (has links)
The aim of the diploma thesis is to find out by measuring the production of carbon dioxide that man produces in various types of physical activity. Using the model, the goal is to simulate real carbon dioxide production for a type object and to design a way of automatic regulation, air supply and drainage to obtain better indoor environment (represented by carbon dioxide).
113

Decentralizovaný systém řízení vytápění budov / DCS for building control

Kopeček, Petr January 2008 (has links)
This thesis deals with DCS for bulding control. The main aim was to develop a general system, which can be adapted according to the individual requirements and which should minimize costs too. Hardware modules, communication bus, communication protocol, system topology and regulation mechanisms, have been designed. Regulators have been set. There are introduced current realization and possible future extensions too. The high security and the high functionality topics are included.
114

Kartläggning av Cytivas koldioxidutsläpp till följd av inomhustemperaturreglering / Mapping of Cytiva's carbon dioxide emissions as a result of indoor temperature control

Green, Oscar, Pettersson, Sixten, Stenberg, Isabell, Fält, Daniel, Sköld, Sofie, Lagerqvist, Nicklas January 2022 (has links)
This is a study conducted on behalf of the pharmaceutical company Cytiva in Uppsala via STUNS Energi by students at Uppsala university. The goal for Cytiva is to reduce their carbon dioxide footprint and the purpose of this study is to evaluate the possibilities of reducing their carbon dioxide emissions from the heating and cooling of their facilities, mainly office buildings. The office buildings used for the study are the older A-buildings and the more modern D1 building. The main issue used in formulating the method for this study was “How does Cytivas CO2-emission behave in regards to their indoor temperature regulation?” A separate issue using the results from the first mentioned issue is to provide an answer to “How does Cytivas CO2-emission behave in the future?” and with this help Cytiva plan ahead for the future. A data study was conducted and was supplemented by a literature study. The data was provided by Cytiva and their partners for temperatures in the buildings, outdoor temperatures, and their heat energy consumption. Key figures for the CO2-emission could be used to calculate the emissions from the heating and cooling of the buildings. In the end a linear behavior between the outdoor temperature difference and their heat energy consumption was proven and a linear model was created in order to predict changes in their CO2-emission from altering the indoor temperature. Also a difference between the efficiency in the buildings was proven, where the D1 building would be considered superior to the A- buildings. / Denna studie utfördes på uppdrag och efterfrågan av Cytiva via STUNS Energi av studenter på Uppsala universitet. Syftet var att analysera och kvantifiera hur regleringen av inomhustemperaturen i Cytivas kontorslokaler påverkar koldioxidemissionen. Kontorslokalerna som undersöktes är belägna i Uppsala och är två äldre hus, A1 och A2 samt ett nyare hus, D1. Huvudmålet med studien var att informera Cytiva om deras koldioxidutsläpp till följd av deras temperaturreglering inomhus. Den primära frågeställningen som besvarades med hjälp av studien är “Hur ser Cytivas koldioxidutsläpp ut från inomhustemperaturreglering?”. Ett ytterligare mål med studien var att hitta en generell modell som kan appliceras för att simulera framtidens koldioxidutsläpp. Modellen kunde vidare ge svar på studiens andra frågeställning som lyder “Hur ser Cytivas koldioxidutsläpp ut vid modellering för framtiden?”. Studien genomfördes genom datahantering, tolkning av data samt med hjälp av en förstudie. Den behandlade data bestod av utomhus-, inomhus- och tilluftstemperaturer samt energiförbrukningen för husen. Den första frågeställningen besvarades med hjälp av att ett samband togs fram mellan energiförbrukningen och skillnaden mellan utomhus- och inomhustemperaturen korrigerad med en konstant. Energiförbrukningen kunde sedan konverteras till koldioxidutsläpp med hjälp av ett nyckeltal för fjärrvärme. Till exempel var Cytivas totala koldioxidutsläpp 189 ton från fjärruppvärmningen i hus D1 under hela 2021. För A-husen användes samma metod som för D1 förutom att inomhustemperaturen ersattes av tilluftstemperaturen på grund av saknad data. A-husens koldioxidutsläpp till följd av fjärruppvärmning under hela 2021 var 158 ton. Den andra frågeställningen besvarades genom att modellen som konstruerades för den första frågeställningen användes. Studien resulterade i en skillnad mellan byggnaderna och att det finns ett tydligt samband mellan fjärrvärmeförbrukningen och utomhustemperaturen. Byggnaderna skiljer sig från varandra men ungefär samma slutsats kan dras. Eftersom utomhustemperaturen kommer öka till följd av den globala uppvärmningen kommer värmeförbrukningen minska medan kylning av lokalerna kommer öka för att uppnå en komfortabel inomhustemperatur. I framtiden kommer alltså koldioxidutsläppen från Cytivas inomhustemperaturreglering minska i jämförelse med hur det ser ut i dagsläget. Om inomhustemperaturen höjs i D1 med en grad kan utsläppen öka med upp till 16 % och en sänkning med en grad kan leda till minskade utsläpp med upp till 15 %.

Page generated in 0.1329 seconds