• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 192
  • 107
  • 22
  • 15
  • 11
  • 7
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 2
  • Tagged with
  • 426
  • 426
  • 169
  • 167
  • 84
  • 75
  • 64
  • 59
  • 52
  • 48
  • 48
  • 46
  • 46
  • 38
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da resistência á flexão e determinação das propriedades mecânicas de resinas compostas e sua aplicação no método dos elementos finitos /

Piccioni, Máyra Andressa Rodrigues Valinhos. January 2010 (has links)
Orientador: José Roberto Cury Saad / Banca: Pedro Yoshito Noritomi / Banca: Edson Alves de Campos / Resumo: O Método de Elementos Finitos (MEF) constitui-se de uma ferramenta de amplo uso que permite, em computador, simular condições específicas em um material e determinar sua resposta para essas condições. O MEF pode ser utilizado em diversas áreas das ciências e, devido à sua grande aplicabilidade e eficiência, trabalhos com esta metodologia têm sido realizados nas diversas especialidades odontológicas, quando se deseja analisar comportamento mecânico. O objetivo deste trabalho foi determinar a resistência à flexão de resinas compostas "in vitro", suas propriedades mecânicas e comprovar a aplicabilidade do Método dos Elementos Finitos nas mesmas. As resinas compostas selecionadas para esse trabalho foram: Nano-híbrida (Tetric NCeram - Ivoclar Vivadent), Nanoparticulada (Filtek Z350 - 3M Espe) e Microparticulada (Heliomolar - Ivoclar Vivadent). A primeira etapa do trabalho foi a execução do ensaio de resistêcia à flexão segundo a norma ISO no 4049:1988 no qual os corpos de prova foram confeccionados usando uma matriz metálica. O material restaurador foi inserido e acomodado na cavidade da matriz até o preenchimento com mínimo excesso. Após o preenchimento da matriz, a resina composta foi fotoativada. Após a fotopolimerização, o corpo de prova permaneceu em repouso, para em seguida, ser cuidadosamente separado da matriz e imerso em água destilada e em seguida polido. Posteriormente, foram armazenados em água destilada, à temperatura de 37oC, por 24 horas. Os espécimes foram retirados da água, secos, e suas dimensões verificadas e inseridas na fórmula para o cálculo da resistência à flexão. Então, o teste de resistência à flexão foi executado. A segunda etapa do trabalho consistiu em determinar as propriedades mecânicas: coeficiente de Poisson e módulo de Young (módulo de elasticidade) dessas resinas compostas segundo a norma... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The Finite Element Method (FEM) consists of a tool of ample use that allows, in computer, to simulate specific conditions in a material and to determine their behavior for these conditions. The FEM can be used in various fields of sciences and, because of its wide applicability and efficiency, works with this methodology have been conducted in various dental specialties, when we want to analyze mechanical behavior. The aim of this study was to determine the flexural strength of composite resins in vitro, their mechanical properties and prove the applicability of the Finite Element Method in them. The composite resins were selected for this work were: Nano-hybrid (Tetric N-Ceram - Ivoclar Vivadent), nanoparticulated (Filtek Z350 - 3M Espe) and microparticulated (Heliomolar - Ivoclar Vivadent). The first stage of this work was the flexural strenght test according to ISO 4049:1988 where the specimens were prepared using a metal matrix. The restorative material was inserted and accommodated in the cavity of the matrix filling it with minimal excess. After filling the matrix, the composite was light cured. After curing, the specimen remained at rest, to then be carefully separated from the matrix and immersed in distilled water and then polished. Were subsequently stored in distilled water at a temperature of 37oC for 24 hours. The specimens were removed from water, dried, and its dimensions recorded and entered into the formula for calculating the flexural strength. Then, the test was performed. The second stage of the study was to determine the mechanical properties: Poisson's Ratio and Young's Modulus (Modulus of Elasticity) of these composites according to ASTM D638 - 01, where the specimens were prepared using a matrix and the material cured subjected to the test in a tensile testing machine. The third stage of this work was to generate a CAD model with the mechanical properties:... (Complete abstract click electronic access below) / Mestre
122

Efeito da excitação ultrasônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro, após diferentes períodos de armazenamento

Azevedo, Elcilaine Rizzato [UNESP] 31 July 2008 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2008-07-31Bitstream added on 2014-06-13T18:56:30Z : No. of bitstreams: 1 azevedo_er_me_arafo.pdf: 268574 bytes, checksum: 3acb7b065102ea435408134a95258b11 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo investigou o efeito da excitação ultra-sônica na resistência máxima à tração e de união à dentina de cimentos de ionômero de vidro (CIV), após 24 horas ou 30 dias de armazenamento em água destilada à 37ºC, por meio do teste de microtração. Os materiais utilizados foram o CIV de alta viscosidade Fuji IX GP, Ketac Molar e o modificado por resina, Vitremer. Foram confeccionados 12 corpos de prova para cada material, dos quais 6 formaram o grupo controle e 6 receberam tratamento com US, por 30 segundos. Para o experimento de resistência de união à dentina, trinta e seis terceiros molares foram divididos aleatoriamente entre os grupos experimentais já descritos. Em ambos os experimentos, após o período de armazenamento, os corpos de prova foram seccionados em espécimes com área adesiva média de 0,91mm2 (± 0,1) e 0,93 mm2 (± 0,09), respectivamente para o experimento de resistência à tração e de união. Os dados foram analisados pela análise de variância com a correção de Welch (p<0,001) e teste de Tamhane (α = 0,05). O cimento Fuji IX (24 horas) apresentou aumento significativo na resistência máxima à tração e o Ketac Molar (24 horas) na resistência de união à dentina, após a aplicação do US. Os grupos controle destes materiais também apresentaram aumento da resistência após 30 dias de armazenamento. Em todos os outros grupos experimentais não houve alteração significativa após a aplicação de US ou após diferentes períodos de armazenamento. A aplicação do ultra-som aumentou a resistência máxima à tração e de união à dentina, após 24 horas de armazenamento, quando se utilizou respectivamente, os cimentos Fuji IX e Ketac Molar. / This study investigated the GICs ultimate tensile strength and bond to dentine after ultrasonic excitation and after periods of the 24 hours and 30 days storage in distilled water at 37ºC, using microtensile test. Two high viscosity GICs, Fuji IX GP and Molar Ketac, and the resin modified GIC Vitremer were used. Twelve specimens for each material were prepared, 6 formed the control group and 6 received treatment with US, por 30 seconds. For the ultimate tensile strength experiment, a cross-sectional area of 0.91mm2 (± 0.1) in the specimens were obtained. For the tensile bond strength to dentine test, 36 third molar were selected and randomly divided into groups, with a cross-sectional area of 0.93 mm2 (± 0.09). All specimens were tested in a microtensile test machine. The data were evaluated by analysis of variance and corrected by Welch (p<0.001) and Tamhane tests (α = 0.05). Fuji IX (24 hours) had significant increase in the ultimate tensile strength and Ketac Molar (24 hours) had significant increase in the tensile strength of union to dentine, after the application of the US. The control groups of the Fuji IX and Ketac Molar had increase in the tensile strength after 30 days of storage. All the other groups, did not show significant difference neither when US application was used nor between different storage times. The ultrasound application increased the ultimate tensile strength and bond to the dentine, after 24 hours of storage, when if it used respectively, the Ketac Molar and Fuji IX cements.
123

Inter-relação do comprimento dos prolongamentos resinosos (tags) e da espessura da camada híbrida de adesão, com a resistência de união de sistemas adesivos ao tecido dentinário

Rahal, Vanessa [UNESP] 06 February 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-02-06Bitstream added on 2014-06-13T19:10:17Z : No. of bitstreams: 1 rahal_v_me_araca.pdf: 1283772 bytes, checksum: 8c48fcbb5450bb565918794bd4285d39 (MD5) / O objetivo deste estudo foi analisar a correlação da espessura da camada híbrida de adesão e do comprimento dos prolongamentos resinosos (tags), com a resistência de união em tecido dentinário hígido, de um sistema adesivo convencional e de outro autocondicionante. Após a realização “in vivo” dos procedimentos restauradores, os dentes foram extraídos e seccionados no sentido mésio/distal. Em uma secção dental foi realizada a análise microscópica dos prolongamentos resinosos e da camada híbrida de adesão. Para tanto, os espécimes foram descalcificados, incluídos em parafina e cortados a uma espessura de 6 μm. Os cortes foram corados pelo método Brown e Brenn, para posterior análise e mensuração em microscópio óptico comum Axiophot Zeiss em 1000× (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). O remanescente dental foi acoplado à cortadeira metalográfica ISOMET 1000 (Buehler, Lake Bluff, IL, USA), de forma a permitir a realização de secções transversais, destinados ao teste de microtração (Instron modelo 4411 - Instron Inc., Canton, MA, EUA), sendo tracionados a 0,5 mm/min até sua ruptura. A superfície fraturada foi classificada segundo o padrão de fratura após análise sob lupa estereoscópica Stemi SV 11 (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden-Württemberg, Germany) em aumento de 40×. Os valores obtidos no teste de microtração, na análise dos tags e da camada híbrida correspondentes a cada espécime e grupo de estudo, foram submetidos à análise estatística, com a realização do teste de Correlação de Pearson, não sendo verificada correlação entre os valores de resistência de união e a espessura da camada híbrida e comprimento dos tags resinosos em nenhum dos sistemas adesivos estudados. / The purpose of this study was to evaluate the possibility of the correlation between the hybrid layer thickness, the resin tag length, and the resin bond strength of a conventional and a self-etching adhesive system into sound dentin tissue. After “in vivo” restorative procedures were performed, each specimen was extracted and sectioned in a mesiodistal direction. One of the dental sections was then analyzed on a light microscope where the hybrid layer thickness and resin tag length were measured. For this experiment, the specimens were decalcified, embedded in paraffin and serially sectioned at a thickness of 6 μm. The sections were subsequently stained using Brown and Brenn stain for posterior analysis and for the measurement of the hybrid layer thickness and the resin tag length on a Zeiss Axiophot light microscope at 1000× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The other section was mounted onto a metallographic cutter ISOMET 1000 (Buehler, Lake Bluff, IL, USA) and was sectioned. A microtensile test was subsequently performed (Instron modelo 4411 - Instron Inc., Canton, MA, USA) with a crosshead speed of 0.5 mm/min. The fractured surfaces were analyzed and the fracture pattern was characterized using a stereoscopic magnifying glass Stemi SV 11 at a 40× magnification (Carl Zeiss Company - DSM-940 A, Oberkochen, Baden- Württemberg, Germany). The results were subjected to Pearson Correlation Test and verified that the hybrid layer thickness and the resin tag length did not correlate with the bond strength of the adhesives systems.
124

Resistência de união de um sistema adesivo irradiado com laser Nd:YAG em dentina tratada com laser de Er:YAG

Malta, Daniel Alexandre Menezes Pedrosa [UNESP] 27 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-27Bitstream added on 2014-06-13T19:51:20Z : No. of bitstreams: 1 malta_damp_me_arafo.pdf: 3852992 bytes, checksum: d55fbc5b212b5a71eaa602dda984e5e6 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / A proposta deste estudo foi avaliar por meio do teste de microtração a resistência de união de um sistema adesivo irradiado com laser de Nd:YAG em dentina preparada com laser de Er:YAG. Estudos prévios têm demonstrado que a irradiação com laser após a aplicação do sistema adesivo é eficiente em alcançar alta força de união à tensão e ao cisalhamento. O laser de Er:YAG (Twinlight, Fotona, Eslovênia) com fluência de 60 J/cm2 foi usado para o tratamento da dentina. A irradiação do adesivo foi realizada usando o laser de Nd:YAG (Twinlight, Fotona, Eslovênia) com fluência de 100 J/cm2. As restaurações foram executadas com Adper Single Bond 2/Z250 (3M/ESPE, EUA). Vinte terceiros molares recentemente extraídos e livres de cárie foram empregados. Os dentes foram divididos em quatro grupos experimentais (n = 5): (G1) grupo controle onde não houve irradiação; (G2) irradiação do sistema adesivo com laser de Nd:YAG; (G3) tratamento da dentina com laser de Er:YAG; (G4) tratamento da dentina com laser de Er:YAG mais irradiação do sistema adesivo com laser de Nd:YAG. Um dente de cada grupo foi preparado para avaliação da interface adesiva sob microscopia eletrônica de varredura (MEV). Adicionalmente foi realizada a análise do padrão de fraturas, resultante dos ensaios mecânicos, sob microscopia óptica digital. Os testes de microtração foram realizados em uma máquina de ensaios mecânicos com célula de carga de 1 kN a uma velocidade de 0,5 mm/min. A análise estatística (ANOVA e teste de Tukey), dos dados referentes aos ensaios mecânicos, evidenciaram diferença estatística significante entre os grupos G1 e G3, G1 e G4, G2 e G3, e G2 e G4 e semelhança entre os grupos G1 e G2, e G3 e G4. As fraturas adesivas foram predominantes em todos os grupos experimentais. / The purpose of this study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine treated with Er:YAG laser. Previous studies had shown that laser irradiation after the application of an adhesive system is efficient in achieving higher shear bond and tensile bond strength. Er:YAG laser (Twinlight, Fotona, Slovenia) with fluency of the 60 J/cm2 was used for the treatment of the dentine. The irradiation of the adhesive was performed using the Nd:YAG laser (Twinlight, Fotona, Slovenia) with the fluency of the 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250 (3m/ESPE, USA). Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group where there was no irradiation; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) treatment of the dentin with Er:YAG laser; (G4) treatment of the dentin with Er:YAG laser plus irradiation of the adhesive system with Nd:YAG laser. One tooth of each group was prepared for evaluation of adhesive interface under scanning electron microscopy (SEM). In addition was performed an evaluation of the bond failures under digital optic microscopy. The micro tensile bond tests were performed in a MTS universal testing machine with 1 kN load cell at cross-head speed 0,5 mm/min. The statistical analysis (ANOVA and Tukey test) showed difference significant statistics between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all experimental groups.
125

Avaliação da resistência á flexão e determinação das propriedades mecânicas de resinas compostas e sua aplicação no método dos elementos finitos

Piccioni, Maýra Andressa Rodrigues Valinhos [UNESP] 04 August 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-08-04Bitstream added on 2014-06-13T20:31:08Z : No. of bitstreams: 1 piccioni_marv_me_arafo.pdf: 3029989 bytes, checksum: fefc5b2c8df5ca74c8c18b8ed92b7132 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O Método de Elementos Finitos (MEF) constitui-se de uma ferramenta de amplo uso que permite, em computador, simular condições específicas em um material e determinar sua resposta para essas condições. O MEF pode ser utilizado em diversas áreas das ciências e, devido à sua grande aplicabilidade e eficiência, trabalhos com esta metodologia têm sido realizados nas diversas especialidades odontológicas, quando se deseja analisar comportamento mecânico. O objetivo deste trabalho foi determinar a resistência à flexão de resinas compostas “in vitro”, suas propriedades mecânicas e comprovar a aplicabilidade do Método dos Elementos Finitos nas mesmas. As resinas compostas selecionadas para esse trabalho foram: Nano-híbrida (Tetric NCeram - Ivoclar Vivadent), Nanoparticulada (Filtek Z350 – 3M Espe) e Microparticulada (Heliomolar – Ivoclar Vivadent). A primeira etapa do trabalho foi a execução do ensaio de resistêcia à flexão segundo a norma ISO no 4049:1988 no qual os corpos de prova foram confeccionados usando uma matriz metálica. O material restaurador foi inserido e acomodado na cavidade da matriz até o preenchimento com mínimo excesso. Após o preenchimento da matriz, a resina composta foi fotoativada. Após a fotopolimerização, o corpo de prova permaneceu em repouso, para em seguida, ser cuidadosamente separado da matriz e imerso em água destilada e em seguida polido. Posteriormente, foram armazenados em água destilada, à temperatura de 37oC, por 24 horas. Os espécimes foram retirados da água, secos, e suas dimensões verificadas e inseridas na fórmula para o cálculo da resistência à flexão. Então, o teste de resistência à flexão foi executado. A segunda etapa do trabalho consistiu em determinar as propriedades mecânicas: coeficiente de Poisson e módulo de Young (módulo de elasticidade) dessas resinas compostas segundo a norma... / The Finite Element Method (FEM) consists of a tool of ample use that allows, in computer, to simulate specific conditions in a material and to determine their behavior for these conditions. The FEM can be used in various fields of sciences and, because of its wide applicability and efficiency, works with this methodology have been conducted in various dental specialties, when we want to analyze mechanical behavior. The aim of this study was to determine the flexural strength of composite resins in vitro, their mechanical properties and prove the applicability of the Finite Element Method in them. The composite resins were selected for this work were: Nano-hybrid (Tetric N-Ceram - Ivoclar Vivadent), nanoparticulated (Filtek Z350 - 3M Espe) and microparticulated (Heliomolar - Ivoclar Vivadent). The first stage of this work was the flexural strenght test according to ISO 4049:1988 where the specimens were prepared using a metal matrix. The restorative material was inserted and accommodated in the cavity of the matrix filling it with minimal excess. After filling the matrix, the composite was light cured. After curing, the specimen remained at rest, to then be carefully separated from the matrix and immersed in distilled water and then polished. Were subsequently stored in distilled water at a temperature of 37oC for 24 hours. The specimens were removed from water, dried, and its dimensions recorded and entered into the formula for calculating the flexural strength. Then, the test was performed. The second stage of the study was to determine the mechanical properties: Poisson's Ratio and Young's Modulus (Modulus of Elasticity) of these composites according to ASTM D638 - 01, where the specimens were prepared using a matrix and the material cured subjected to the test in a tensile testing machine. The third stage of this work was to generate a CAD model with the mechanical properties:... (Complete abstract click electronic access below)
126

Avaliação da resistência adesiva à microtração após desproteinização da dentina. Efeito de diferentes sistemas adesivos

Farias, Caroline Leão Cordeiro de [UNESP] 07 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:09Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-07Bitstream added on 2014-06-13T18:51:45Z : No. of bitstreams: 1 farias_clc_me_arafo.pdf: 808344 bytes, checksum: 95ebf651344a3331fa67cd1e8c616f15 (MD5) / O objetivo deste trabalho foi avaliar, in vitro, os efeitos da desproteinização da dentina sobre a resistência de união de três diferentes sistemas adesivos. Para tal, 30 terceiros molares humanos hígidos foram seccionados transversalmente, por meio de disco diamantado, na união do terço médio com o terço oclusal e desgastados com discos de lixa de granulação 320 e 600 para completa exposição da superfície dentinária e padronização da smear layer. Em seguida, os dentes foram divididos aleatoriamente em 6 grupos (n=5), os quais receberam aplicação dos sistemas adesivos Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) de acordo com as instruções dos fabricantes (Grupos 2, 4 e 6, respectivamente) ou após desproteinização da dentina com hipoclorito de sódio a 5% durante 2 minutos (Grupos 1, 3 e 5, respectivamente). Restaurações de resina composta Z100 foram confeccionadas, de forma incremental, sobre toda a superfície oclusal. Os dentes foram, então, seccionados com disco diamantado com a finalidade de obter amostras em forma de palitos de 1,0 l 0,2mm2 de área adesiva. Vinte e cinco amostras de cada grupo foram selecionadas e armazenadas por 24 horas em água destilada a temperatura de 37ºC. Em seguida, os testes de microtração foram realizados em Máquina Universal de Ensaios MTS, à velocidade do atuador de 0,5mm/min. Os resultados, analisados estatisticamente por meio de Análise de variância e Teste de Tukey (p<0,05), indicaram que a aplicação do NaOCl proporcionou redução da resistência adesiva para todos os grupos (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) quando comparados com os grupos controle (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Em relação aos padrões de fratura, observou-se predominância de fraturas adesivas, sendo que estas, nos grupos onde a dentina foi... . / The aim of this study was to evaluate, in vitro, the influence of dentin deproteinization on microtensile bond strength of three different adhesive systems. Thirty freshly extracted human molars were transversely wetcut using a diamond disk in order to expose the oclusal dentin surface. The teeth were randomly divided into 6 groups (n=5) and the adhesive systems Prime & Bond 2.1 (Dentsply), Single Bond (3M) e Clearfil SE Bond (Kuraray) were applied according to the manufacturer's instruction (control groups: G2, G4 and G6) or after application of sodium hypochlorite 5% for 2 minutes (G1, G3 and G5). The teeth were restored with Z100 (3M) composite resin and the microtensile specimens, with a bonded area of 1,00l 0,2mm2, were prepared by a slow-speed diamond disk. Twenty-five specimens of each group were selected and stored in distilled-water at 37oC for 24 hours. The microtensile tests were performed in a MTS universal testing machine with a cross-head speed of 0,5mm/min. The results were statistically analyzed by ANOVA and Tukey's test (p=0,05). Sodium hypochlorite pre-treatment significantly decreased the microtensile bond strength values of all adhesive systems (G1- 29,16 l 3,98; G3- 23,06 l 4,87; G5- 26,71 l 5,10) compared to control groups (G2- 33,11 l 5,76; G4- 30,62 l 5,47; G6- 32,09 l 6,43). Analysis of the morphology of the failure pattern revealed that, for the control specimens, debonding had occurred in the composite/teeth interface and in specimens that were etched and deproteinized, debonding was characterized by resin failure through the wide bases of the tag extensions into dentinal tubules.
127

Influência do teor de hidrogênio no gás de proteção sobre as propriedades mecânicas de juntas soldadas do aço ASTM A-36

Silva, Roneles de Santana 11 December 2013 (has links)
Made available in DSpace on 2015-05-08T14:59:53Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 3656231 bytes, checksum: 91c88d760baaa97002fc6dc818b5a4e5 (MD5) Previous issue date: 2013-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This is work study about Conducted, to investigate the influences of hydrogen content of the shielding gas in the behavior of mechanical properties (toughness, hardness, and tensile strength) of steel welded ASTM A36. The test specimens were welded with GMAW and FCAW. That is, we used two mixtures of shielding gas, 75% Ar +25% CO2 in the other containing hydrogen in its composition, 70% Ar +25% CO2 +5% H2. The development experiment was carried out in the completely random with the aid of a procedure known as factorial design (FT), having been used for the variables influencing the type of wire, and gas composition. The replies variables were analyzed tensile strength, toughness and hardness regions of the weld. The results were submitted to analysis variance and 90% confidence interval was utilized. The technique of scanning electron microscopy (SEM) was used to characterize the fracture mode observed in the weld metal and in the thermally affected by the heat. The results showed the hydrogen present in the shielding gas brittled the weld metal, and which were observed bubble formation in the weld metal. / Nesse trabalho foi realizado um estudo para avaliar a influência do teor de hidrogênio do gás de proteção no comportamento das propriedades mecânicas (tenacidade, dureza, resistência a tração) de juntas soldadas do aço ASTM A-36. As juntas foram soldadas com os processos MIG/MAG e Arame tubular. Para isso utilizou-se duas misturas de gás de proteção, 75%Ar+25%CO2 é a outra contendo hidrogênio na sua composição, 70% +25%CO2 +5%H2. O desenvolvimento experimental foi realizado de forma totalmente aleatória, com o auxílio de um procedimento conhecido como planejamento fatorial (PF); foram utilizados como variáveis de influencia o tipo de arame, e a composição do gás. Como variáveis de resposta foram analisadas a resistência a tração, a tenacidade e a dureza das regiões da junta soldada. Os resultados foram submetidos à análise de variância e validado para uma confiança de 90%. A técnica de microscopia eletrônica de varredura (MEV) foi usada para caracterizar os modos de fratura observados no metal de solda e na zona termicamente afetada pelo calor. Os resultados mostraram que o hidrogênio presente no gás de proteção fragilizou o metal de solda (MS), e que houve a formação de bolhas no metal de solda.
128

Influência do tipo de tratamento superficial na força adesiva do reparo com resina composta em materiais estéticos /

Ahid, Fernando Jorge Mendes. January 2003 (has links)
Orientador: Welingtom Dinelli / Banca: Luís Geraldo Vaz / Banca: Marcelo Ferrarezi de Andrade / Banca: Edson Alves de Campos / Banca: Paulo Sérgio Quagliatto / Resumo: Avaliou-se a influência do tipo de tratamento da superfície de materiais estéticos no processo de adesão do reparo com resina composta, por meio do teste de cisalhamento. Foram preparados 360 corpos-de-prova, sendo 120 em cerâmica, 120 em resina composta e 120 em cerômero os quais receberam 06 tipos de tratamentos de superfície a saber, ponta diamantada (GT1C), ponta diamantada e silano (GT1S), jato abrasivo (GT2C), jato abrasivo e silano (GT2S), ácido hidrofluorídrico (GT3C) e ácido hidrofluorídrico e silano (GT3S). O adesivo do Sistema Scotchbond Multipurpose Plus, silano e resina composta Z100 foram aplicados sobre a superfície e os corpos-de-prova armazenados à temperatura de 37oC, por 24 horas, ciclados e novamente armazenados, para em seguida serem cisalhados. A análise estatística dos resultados mostrou que não houve diferença estatística na resistência adesiva dos reparos em resina composta e cerômero, porém, para o material cerâmico, o silano foi eficiente para aumentar a resistência para os tratamentos mecânicos T1 e T2, entretanto, o T3, com ou sem silano, apresentou resistência maior. Os tipos de fraturas foram 100% coesiva do substrato (CS). A microscopia mostrou superfícies com características diferentes para cada material e tratamento superficial. Concluindo os valores de resistência adesiva para a cerâmica sofreram influência do tipo de tratamento e que estes não influenciaram os materiais resinosos. / Abstract: The influence of the types of the surface treatment in esthetic materials in adhesive process, was evaluaed through shear strength test. The samples were constructed and polished, that received the treatment with diamond bursh (GT1C), and silane application (GT1S), jet of abrasive air (GT2C), and silane application (GT2S), hydrofluoric acid gel (GT3C) and silane application (GT3S). The adhesive of Scotchbond Multiporpose Plus System, the silane and Z100 composite resin were applied on this surface and the whole resin/substract was stored to the temperature of 37o.C, for 24 hours. They were thermocicled, stored again and tested in tension. The static analyses of results showed there is not difference in adhesive resistence of repair between composite resin and ceromero, however in ceramic, the silane increased the resistance in T1 and T2. The T3 group silanated and non silanated was observed increase of resistance. The types of fractures that occurred were 100% cohesive. Scanning electronic microscopy analysis revealed different surfaces in differentes estetic materials and diferents types de surface treatments. The present study showed that adhesive resistence of ceramic repair were affected for the type of surface treatment. However the type of surface tratment didn't affected the adhesive resistence of other materials. / Doutor
129

Resistência à flexão, resistência à tração diametral e dureza de sistemas cerâmicos para infra-estrutura /

Schalch, Max von. January 2003 (has links)
Orientador: Carlos Alberto dos Santos Cruz / Banca: Renata Garcia Fonseca / Banca: Alma Blásida Concepción Elizaur Benitez Catirse / Resumo: O objetivo deste estudo foi comparar a resistência à flexão, a resistência à tração diametral e a dureza do material de infra-estrutura dos sistemas cerâmicos IPS-Empress 2/Ivoclar (dissilicato de lítio, processado por injeção) e In-Ceram Zirconia/Vita (óxidos de alumínio e zircônio, processados por dupla sinterização). Foram confeccionadas dez amostras de cada material para o ensaio de flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System - EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada cerâmica foram incluídos em resina acrílica autopolimerizável JET (Artigos Odontológicos Clássico, Brasil), polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Os resultados mostraram maior resistência à flexão do material In-Ceram Zirconia (439,88MPa) em relação ao IPS-Empress 2 (226,13MPa). Entretanto, observou-se maior resistência à tração diametral do IPS-Empress 2 (175,08MPa) em relação ao In-Ceram Zirconia (150,47MPa). Para a dureza Vickers, o material In-Ceram Zirconia (972,0VHN) mostrou-se superior em relação ao IPS-Empress 2 (488,33VHN). / Abstract: The aim of this study was to compare flexural strength, diametral tensile strength and hardness of infra-structure ceramic systems IPS-Empress 2/Ivoclar (litium dissilicate, heat-pressed) and In-Ceram Zirconia/Vita (aluminum and zirconium oxides, Slip casting). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter; 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. In flexural test, In-Ceram Zirconia (439.88MPa) showed greater strength than IPS-Empress 2 (226.13MPa). However, the IPS-Empress 2 (175.08MPa) showed greater diametral strength than In-Ceram Zirconia (150.47MPa). For hardness, the In-Ceram Zirconia (972.0VHN) showed greater than IPS-Empress 2 (488.33VHN). / Mestre
130

Análise "in vitro" da resistência adesiva de resinas compostas em cavidades de classe II, através do teste de microtração. Efeito de diferentes técnicas restauradoras /

Calixto, Abraham Lincoln. January 2003 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Osmir Batista de Oliveira Júnior / Banca: José Roberto Cury Saad / Banca: Paulo Sergio Quagliato / Banca: João Carlos Gomes / Resumo: O objetivo deste trabalho foi analisar in vitro a resistência adesiva, em cavidades de classe II, restauradas com resinas compostas, através do teste de microtração . Foram realizadas cavidades padronizadas, de classe II, tipo slot, nas superfícies mesial e distal de 24 dentes terceiros molares humanos e hígidos. Os dentes foram aleatoriamente divididos em 6 grupos com 16 espécimes cada. O procedimento restaurador foi realizado através de técnica de incrementos múltiplos com as resinas compostas P60 (compactável) e Z250 (multiuso), sob efeito de diferentes técnicas restauradoras, a saber: Grupo PT1- adesivo + P60 ; Grupo PT2- adesivo + P60 + ponta fotocondensadora transparente; Grupo PT3- adesivo + flow + P60; Grupo ZT1- adesivo + Z250; Grupo ZT2- adesivo + Z250 + ponta fotocondensadora transparente; Grupo ZT3- adesivo + flow + Z250. O sistema adesivo utilizado foi o Single Bond (3M ESPE). Após as restaurações, os dentes foram armazenados em água destilada em estufa a 37°C, durante 24 horas. A seguir, os dentes foram termociclados por 500 ciclos (5°-55°) e então, seccionados paralelamente ao longo eixo com disco diamantado, no sentido vestíbulo - lingual e mesio - distal, obtendo-se amostras em forma de palitos, com área de secção transversal de 0,50mmøl0,1mmø . Antes do teste de tração, os palitos tiveram suas áreas de união medidas e anotadas, e então, foram fixados pelas suas extremidades ao dispositivo de microtração com um adesivo instantâneo e a seguir, submetidos ao ensaio de tração em máquina de testes universal (MTS) operada a velocidade de 0,5mm/min. Após a fratura, os valores de resistência adesiva foram calculados e expressos em MPa. O modo da fratura no lado de dentina foi classificada individualmente, com lupa estereoscópica com aumento de 40X. Os dados foram submetidos a análise estatística e demonstrou... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this work was to analyse in vitro of the tensile bond strength in class II cavities, recuperated with composite resins, throught the microtensile bond test. Standardized cavities were prepared, slot type , in the surfaces mesial and distal of 24 humans molars teeth third and health. The restorations procedures were carried out using the technique of multiple increments with P60 and Z250 resin. The teeth were randoly divided in to 6 groups of 16 specimens each, to know: Group PT1- adhesive+P60; Group PT2- adhesive+P60+ transparent photocondenser point; Group PT3-ahesive+flow+P60; Group ZT1-adhesive+Z250; Group ZT2- adhesive+Z250+ transparent photocondenser point; Group ZT3- adhesive+flow+Z250. The adhesive system were utilized Single Bond (3M/ESPE). After the restorations, the teeth were storage in destilled water for 24h at 37°C. After were thermocycled for 500 cycles at preset temperatures of 5° and 55°C, and the teeth were sectioned with a diamond disc, perpendicularly to the adhesive interface in buccal-lingual an mesio-distal directions, being obtained samples in sticks form with cross-sectional areas of 0,5 mmø. Before testing sticks had their measured and logged union areas. The specimens were then attached to a testing apparatus and tensile load was applied by universal machine at a crosshead speed of 0.5mm/min. After the fracture values of the tensile bond strenght were calculated and expressed in MPa. The dentin surfaces surfaces was examined with aid of glass magnifying stereoscopic with 40X, being verifield the way of failures. The results were submitted statistical analysis showed : 1- the largest values of shear bond strenght went to the group PT2, wich associated the resin P60 with the point photocondenser transparent; 2- the groups that you/they the resin flow didn't present... (Complete abstract, click electronic address below) / Doutor

Page generated in 0.068 seconds