• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Naturlig Kylning av Transformator i Inomhusklimat / Natural Cooling of Transformer in Indoor Climate

Backeström, Evelina, Backeström, Saga January 2024 (has links)
Transformatorn har en viktig uppgift för att elsystemet ska fungera optimalt och det är därav väldigt viktigt att den inte går sönder genom att exempelvis överhettas. Från att transformatorn har varit placerad utomhus har det nu blivit allt vanligare att placera den i en omslutande byggnad, vilket påverkar effektiviteten för kylningen av transformatorn. Detta eftersom hastigheten på det passerande luftflödet kring transformatorn blir lägre vilket leder till att temperaturen i luften runtomkring ökar. I detta examensarbete undersöktes lufttemperaturen i en transformatorstation i Västernorrland, i syfte att se hur transformatorn klarar av de belastningar och utomhustemperaturer som den utsätts för. Detta för att kunna säkerställa att temperaturgränser och riktlinjer för interna och externa temperaturer för en transformator uppfylls. Transformatorn som användes i undersökningen har en maximal skenbar effekt på 16 MVA och använder sig av kylsystemet ONAN. Byggnaden runtomkring transformatorn har två ventilationsluckor på nedre långsidan, samt två ventilationsluckor på övre kortsidan.  Målet med undersökningen var att genomföra en teoretisk analys av hur kylningen i den valda transformatorstationen dimensioneras, där simuleringar även skulle göras i syfte att validera den teoretiska analysen. De belastningar som undersökts har utgått ifrån tillhandahållna data ifrån den högsta lasten under en vanlig sommar- och vinterdag. Ett framtida fall har även undersökts där lasten antas gå på märkeffekt under en längre tidsperiod samt under en väldigt varm sommardag, för att se hur hårt transformatorn kan belastas i extrema förhållanden utan att gränser och riktlinjer överskrids. Det framtida fallet har delats upp i två scenarier, extremfall 20 samt extremfall 30, där skillnaden är vilken temperatur in i transformatorstationen de har. Alternativa lösningar för ventilationsluckorna har även studerats, gällande placering på väggar, storlekar samt gallers modell. Matematiska beräkningsmodeller för bland annat luftflödet, stationstemperaturen samt lindningsoch oljetemperaturer utvecklades fram under arbetet gång, vilka samlades i en Excel beräkningsmall. Simuleringar av byggnaden och transformatorn gjordes i COMSOL Multiphysics, där både 2D och 3D modeller undersöktes i syfte att dels analysera värmespridningen i oljan, dels den naturliga ventilationen. Utifrån de matematiska beräkningsmodellerna framgick det att vinterfallet körde på ca 49% belastning, medan sommarfallet körde på ca 10% belastning. Dessa båda fallen klarade alla gränser och riktlinjer kring externa och interna temperaturer för alla areastorlekar, placeringar och gallersmodeller som testades. I extremfallen uppfylldes de interna temperaturökningsgränserna, men extremfall 30 klarade inte den externa temperaturgränsen i något simuleringstest. Skulle ett extremfall 30 i framtiden inträffa, bör fläktar vid radiatorerna eller ventilationsluckorna övervägas, alternativt en större lucköppning där det enligt framräknade resultat behövs en förstoring av öppningarna på 57%. Ytterligare ett alternativ skulle kunna vara att placera ventilationsluckorna i taket, då detta visade sig ge bästa möjliga kylning av transformatorn i simuleringarna. Detta examensarbete skulle kunna användas som en grund inför framtida undersökningar och den framarbetade Excel beräkningsmallen kan användas som riktlinje vid dimensionering av inomhustransformatorstationer. / The transformer plays a crucial role for the electrical system to function optimally, making its reliability vital to prevent issues such as overheating. Traditionally, the transformer has been positioned outdoors. Nowadays it has become increasingly common to house transformers in enclosed buildings, which affects the cooling efficiency of the transformer. This enclosure reduces the speed of airflow around the transformer, subsequently raising the ambient air temperature. In this thesis, the air temperature in a transformer station in Västernorrland was investigated, to assess how the transformer withstands the loads and external temperatures it encounters. This to ensure that requirements and guidelines for internal and external temperatures for the transformer are met. The transformer used in the study has a maximum apparent power of 16 MVA and uses the ONAN cooling system. The enclosing building is equipped with two ventilation hatches on the longer lower side and two on the shorter upper side.  The aim of the investigation was to conduct a theoretical analysis of the cooling system’s dimensions at the selected substation, complemented by simulations to validate the theoretical findings. The loads investigated have been based on the data provided from the highest load during a normal summer and winter day. Additionally, a future scenario was explored where the transformer operates at rated power for extended periods during a very hot summer day to determine the maximum load the transformer can handle under extreme conditions without breaching the set requirements and guidelines. The future case has been divided into two scenarios, extreme case 20 and extreme case 30, where the difference is what temperature into the substation they have. Alternative design solutions for the ventilation hatches have also been studied, regarding placement on walls, sizes, and fire damper model. Mathematical calculation models for, among other things, the air flow, station temperature, winding- and oil temperatures were developed during the project and compiled into an Excel calculation template. Simulations of the building and the transformer were made in COMSOL Multiphysics, analysing both 2D and 3D models with the aim of studying the heat spread in the oil and the natural ventilation.  The mathematical models showed that the winter scenario operated at approximately 49% load, while the summer scenario operated at about 10% load. These two cases passed all requirements and guidelines regarding external and internal temperatures for all tested hatch sizes and locations. In the extreme cases, the internal temperature rise requirement was met. However, extreme 30 failed to meet the external temperature requirement in any simulation test. Should an extreme case 30 occur in the future, fans at the cooling fins or ventilation hatches may be necessary, or potentially enlarging the hatch openings by 57% as suggested by the calculations. Another alternative could be placing the ventilation hatches on the roof, as this arrangement provided optimal cooling in the simulations. This thesis could be used as a basis for future investigations and the developed Excel calculation template can be used as a guideline when dimensioning indoor transformer stations.
2

Development of Battery Thermal Models For Application In Small Handheld Tools / Utveckling av termiska batterimodeller för användning i små handhållna verktyg

Pandey, Protik January 2024 (has links)
With the advent and increasing influence of lithium-ion batteries, it is imperative to devise the means for realizing a safe operation of the same. Battery modelling of lithium-ion cells is a means to comprehend the cell behaviour. A battery model includes both physical and mathematical modelling with each having their individual pros and cons. Depending on the scale of the battery model resolution the complexity and computational time increases. This thesis work deals with the development of a thermal model for 18650 cylindrical lithium-ion cells. This model encapsulates the thermal behaviour of the STB4 product at Atlas Copco and the battery model development has been done in conjunction with a 3D Computational Fluid Dynamic (CFD) analysis in Ansys Fluent to comprehend the heat distribution over the product surface and identify thermal bottlenecks. The model selection has been done based on the required level of functionality and its effect on the computational time. The proposed NTGK electrochemistry model in this thesis based on the Circuit Network solution method, provides an optimal balance between computational efficiency and model accuracy. The consolidated battery model and analysis results provide crucial insight towards the thermal patterns of the lithium cells and help indicate deviations in case of potential unsafe operation. The simulation model has been validated against the physical experimental tests performed on the battery pack and the STB4 provided by Atlas Copco. Finally, an approach towards a future software implementation of the developed model is outlined in this thesis. / Med tillkomsten och ökande inflytande av litiumjonbatterier är det absolut nödvändigt att utarbeta medel för att förverkliga en säker drift av desamma. Batterimodellering av litiumjonceller är ett sätt att förstå cellens beteende. En batterimodell inkluderar både fysisk och matematisk modellering där var och en har sina individuella för- och nackdelar. Beroende på storleken på batterimodellens upplösning ökar komplexiteten och beräkningstiden. Detta examensarbete behandlar utvecklingen av en termisk modell för 18650 cylindriska litiumjonceller. Denna modell kapslar in det termiska beteendet hos STB4-produkten hos Atlas Copco och utvecklingen av batterimodeller har gjorts i samband med en 3D Computational Fluid Dynamic (CFD)-analys i Ansys Fluent för att förstå värmefördelningen över produktytan och identifiera termiska flaskhalsar. Modellvalet har gjorts utifrån den funktionalitet som krävs och dess effekt på beräkningstiden. Den föreslagna NTGK elektrokemimodellen i denna avhandling baserad på lösningsmetoden Circuit Network, ger en optimal balans mellan beräkningseffektivitet och modellnoggrannhet. Den konsoliderade batterimodellen och analysresultaten ger avgörande insikt om litiumcellernas termiska mönster och hjälper till att indikera avvikelser i händelse av potentiell osäker drift. Simuleringsmodellen har validerats mot de fysiska experimentella testerna som utförts på batteripaketet och STB4 från Atlas Copco. Slutligen beskrivs ett tillvägagångssätt för en framtida mjukvaruimplementering av den utvecklade modellen i denna avhandling.
3

Modelling of Laser Welding of Aluminium using COMSOL Multiphysics

Chen, Jie January 2020 (has links)
This thesis presents a modelling approach of laser welding process of aluminium alloy from the thermo-mechanical point of view to evaluate the occurrence of hot cracking based on simulation results and relevant criteria. The model was created stepwise in COMSOL Multiphysics, starting with the thermal model where heat conduction of solid and liquid phase was computed. Then the CFD model was created by involving the driving forces of liquid motion in the weld pool, i.e. natural convection and Marangoni effect. Lastly, the temperature profile calculated by the CFD model was loaded into the mechanical model for computation of thermal stress and strain. The mechanical results were required in  criteria for measuring the  susceptibility of hot cracking. The main findings include that Marangoni effect plays a dominant role in generating the fluid flow and convective heat flux in the weld pool, thus enhancing the heat dissipation and lowering temperature in the workpiece. By contrast, such temperature reduction caused by the air convection, radiation and natural convection is negligible. The welding track further from the clamped side experiences smaller transversal residual stress, but it does not necessarily suggest higher susceptibility to hot cracking according to the applied criteria. It can be concluded judging from current results that these first models of laser welding process work satisfactorily. There is still a work to do to obtain the full maturity of this model due to its limitation and some assumptions made for simplicity. / Denna avhandling presenterar en modelleringsmetod för lasersvetsningsprocessen av aluminiumlegering ur termomekanisk synvinkel för att utvärdera förekomsten av het sprickbildning baserat på simuleringsresultat och relevanta kriterier. Modellen skapades stegvis i COMSOL Multiphysics, med början med den termiska modellen där värmeledning av fast och flytande fas beräknades. Sedan skapades CFD-modellen genom att involvera drivkrafterna för flytande rörelse i svetsbassängen, dvs. naturlig konvektion och Marangoni-effekt. Slutligen laddades temperaturprofilen beräknad av CFD-modellen in i den mekaniska modellen för beräkning av termisk stress och töjning. De mekaniska resultaten krävdes i kriterier för att mäta känsligheten för het sprickbildning. De viktigaste resultaten inkluderar att Marangoni-effekten spelar en dominerande roll när det gäller att generera vätskeflödet och konvektivt värmeflöde i svetsbassängen, vilket förbättrar värmeavledningen och sänker temperaturen i arbetsstycket. Däremot är sådan temperaturreduktion orsakad av luftkonvektion, strålning och naturlig konvektion försumbar. Svetsbanan längre från den fastspända sidan upplever mindre tvärgående restspänning, men det föreslår inte nödvändigtvis högre känslighet för hetsprickning enligt de tillämpade kriterierna. Man kan dra slutsatsen utifrån aktuella resultat att dessa första modeller av lasersvetsningsprocesser fungerar tillfredsställande. Det finns fortfarande ett arbete att göra för att få full mognad för denna modell på grund av dess begränsning och vissa antaganden för enkelhetens skull.

Page generated in 0.0638 seconds