• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 40
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 42
  • 19
  • 13
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estimativa da evapotranspiração de referencia pelo uso da termometria ao infravermelho / not available

Maggiotto, Selma Regina 06 September 1996 (has links)
O uso eficiente da água na irrigação depende cada vez mais de estudos na área de monitoramento da evapotranspiração. O modelo de Penman-monteith é considerado o mais adequado para a estimativa da evapotranspiração nas diversas condições climáticas. Porém sua adoção implica no desenvolvimento de pesquisas adicionais para a determinação de valores de resistência da cobertura vegetal. Este trabalho objetivou avaliar o uso da temperatura da cobertura vegetal como auxiliar no cálculo da evapotranspiração de referência pelo modelo de Penman-monteith, comparando os resultados com o cálculo feito a partir da parametrização sugerida pela FAO, e com medidas diretas obtidas em lisímetro de pesagem. Foi feito o estudo dos valores de RC em diferentes períodos de tempo e concluiu-se que para o uso da temperatura da cobertura vegetal como auxiliar, o uso de dados do mesmo período de tempo geram valores negativos de RC. O cálculo foi feito utilizando dados instantâneos das 12h e radiação líquida diária. O valor de RC calculado como resíduo da evapotranspiração medida foi bastante superior ao valor sugerido pela FAO. Apesar disso, o modelo sugerido obteve excelente performance na estimativa da ET assim como o uso da temperatura da cobertura vegetal às 12h / not available
2

Estimativa da evapotranspiração de referencia pelo uso da termometria ao infravermelho / not available

Selma Regina Maggiotto 06 September 1996 (has links)
O uso eficiente da água na irrigação depende cada vez mais de estudos na área de monitoramento da evapotranspiração. O modelo de Penman-monteith é considerado o mais adequado para a estimativa da evapotranspiração nas diversas condições climáticas. Porém sua adoção implica no desenvolvimento de pesquisas adicionais para a determinação de valores de resistência da cobertura vegetal. Este trabalho objetivou avaliar o uso da temperatura da cobertura vegetal como auxiliar no cálculo da evapotranspiração de referência pelo modelo de Penman-monteith, comparando os resultados com o cálculo feito a partir da parametrização sugerida pela FAO, e com medidas diretas obtidas em lisímetro de pesagem. Foi feito o estudo dos valores de RC em diferentes períodos de tempo e concluiu-se que para o uso da temperatura da cobertura vegetal como auxiliar, o uso de dados do mesmo período de tempo geram valores negativos de RC. O cálculo foi feito utilizando dados instantâneos das 12h e radiação líquida diária. O valor de RC calculado como resíduo da evapotranspiração medida foi bastante superior ao valor sugerido pela FAO. Apesar disso, o modelo sugerido obteve excelente performance na estimativa da ET assim como o uso da temperatura da cobertura vegetal às 12h / not available
3

Determinação do microclima gerado dentro de uma estrutura a partir de dados ambientais

Leal, Paulo Ademar Martins, 1953- 14 July 2018 (has links)
Orientador : Irenilza de Alencar Naas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-07-14T21:52:05Z (GMT). No. of bitstreams: 1 Leal_PauloAdemarMartins_M.pdf: 5423271 bytes, checksum: 1a8506fd824fd3d3df99590b3359ebc3 (MD5) Previous issue date: 1981 / Mestrado / Agua e Solo / Mestre em Engenharia Agrícola
4

Investigações envolvendo titulação termometrico catalitica

Queiroz, Roldão Roosevelt Urzedo de 15 July 2018 (has links)
Orientador : Oswaldo do Espirito Santo Godinho / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-15T07:50:24Z (GMT). No. of bitstreams: 1 Queiroz_RoldaoRooseveltUrzedode_D.pdf: 5538312 bytes, checksum: e776396cb8b49b853c6e3b532d7ffba9 (MD5) Previous issue date: 1988 / Doutorado
5

Influência da aplicação do Nd:YAG laser sobre sistema adesivo na variação da temperatura pulpar

Silva, Tânia Mara da [UNESP] 25 July 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-07-25Bitstream added on 2014-06-13T20:51:27Z : No. of bitstreams: 1 000757926.pdf: 2887857 bytes, checksum: de6c9419bfca71187528af6e25f128bb (MD5) / O objetivo deste estudo foi avaliar os efeitos da irradiação de Nd:YAG laser e da pressão pulpar simulada na variação de temperatura intrapulpar. Cem molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 2 grupos (n=50) de acordo com a presença e ausência de pressão pulpar simulada. Cada grupo foi dividido em 5 subgrupos (n=10) conforme a variação nos parâmetros de energia do Nd:YAG laser: 60, 80, 100, 120 e 140 mJ. As amostras foram tratadas com: ácido fosfórico 37% (Scotchbond Universal), sistema adesivo Scotchbond Universal (3M ESPE), irradiação com Nd:YAG laser por 60 s e fotopolimerização por 10 s. Avaliou-se a temperatura intrapulpar por meio de um termômetro digital posicionado no corno pulpar mais alto. A pressão pulpar simulada foi de 15 cm de H2O. Para o grupo sem pressão pulpar simulada, a câmara pulpar foi preenchida com pasta térmica. A análise estatística consistiu nos testes ANOVA 2-fatores (parâmetros de energia do laser e pressão pulpar) e Tukey com nível de significância de 5% (p<0,05). Segundo o teste ANOVA 2-fatores todos os fatores (parâmetros de energia do laser e pressão pulpar) apresentaram efeito estatisticamente significante (p<0,05) na variação da temperatura. A maior média (14,30ºC) foi observada no grupo irradiado com 140 mJ sem pressão pulpar simulada, enquanto que a menor média (3,90ºC) foi apresentada pelo grupo irradiado a 60 mJ com pressão pulpar simulada. Observou-se que os grupos irradiados com pressão pulpar simulada apresentaram temperaturas médias inferiores; e as médias aumentaram conforme o aumento dos parâmetros de energia do laser. Assim, concluiu-se que a variação de temperatura durante... / The aim of the present study was to evaluate the effects of Nd:YAG laser irradiation and simulated pulpal pressure on intrapulpal temperature. One hundred sound human molar were sectioned 1 mm below the cementoenamel junction to separate the crown and root portions. A parallel section to the occlusal surfaces exposed 2 mm thickness of dentin. The samples were divided into two groups (n=50) according to presence and absence of simulated pulpal pressure. Each group was divided into five groups (n=10) depending on the variation of Nd:YAG laser energy parameters: 60, 80, 100, 120, 140 mJ. The samples were treated with: phosphoric acid 37% (Scotchbond Universal), adhesive system (Scotchbond Universal/ 3M ESPE), irradiation with Nd:YAG laser for 60 s and light cure for 10 s. A digital thermometer was positioned in the highest pulp horn to evaluate the intrapulpal temperature. The simulated pulpal pressure was of 15 cm. For the group without simulated pulpal pressure, the pulp chamber was filled with thermal paste. Statistical analysis consisted of two-way analysis of variance (ANOVA; laser energy parameters and pulpal pressure) and Tukey’s test with a significance level of 5% (p<0.05). ANOVA revealed statistically significant effect in the temperature range (p<0.05). The highest average (14.30 ºC) was observed in the group irradiated with 140 mJ without pulpal pressure simulation, while the lowest average (3.90 ºC) was observed in the group irradiated at 60 mJ with simulated pulpal pressure. It was observed that the groups treated with simulated pulpal pressure had lower temperature mean values, and the mean values increased with increasing laser energy parameters. Thus, this study concluded that the variation in temperature during laser irradiation is dependent on the energy parameters of Nd:YAG laser and intrapulpal pressure simulation
6

Influência da aplicação do Nd:YAG laser sobre sistema adesivo na variação da temperatura pulpar /

Silva, Tânia Mara da. January 2013 (has links)
Orientador: Sérgio Eduardo de Paiva Gonçalves / Banca: Ricardo Scarparo Navarro / Banca: Maria Filomena Rocha Lima Huhtala / Resumo: O objetivo deste estudo foi avaliar os efeitos da irradiação de Nd:YAG laser e da pressão pulpar simulada na variação de temperatura intrapulpar. Cem molares humanos hígidos foram seccionados 1 mm abaixo da junção amelocementária para separação da coroa da porção radicular e seccionados paralelos à superfície oclusal para exposição de 2 mm de espessura de dentina. As amostras foram divididas aleatoriamente em 2 grupos (n=50) de acordo com a presença e ausência de pressão pulpar simulada. Cada grupo foi dividido em 5 subgrupos (n=10) conforme a variação nos parâmetros de energia do Nd:YAG laser: 60, 80, 100, 120 e 140 mJ. As amostras foram tratadas com: ácido fosfórico 37% (Scotchbond Universal), sistema adesivo Scotchbond Universal (3M ESPE), irradiação com Nd:YAG laser por 60 s e fotopolimerização por 10 s. Avaliou-se a temperatura intrapulpar por meio de um termômetro digital posicionado no corno pulpar mais alto. A pressão pulpar simulada foi de 15 cm de H2O. Para o grupo sem pressão pulpar simulada, a câmara pulpar foi preenchida com pasta térmica. A análise estatística consistiu nos testes ANOVA 2-fatores (parâmetros de energia do laser e pressão pulpar) e Tukey com nível de significância de 5% (p<0,05). Segundo o teste ANOVA 2-fatores todos os fatores (parâmetros de energia do laser e pressão pulpar) apresentaram efeito estatisticamente significante (p<0,05) na variação da temperatura. A maior média (14,30ºC) foi observada no grupo irradiado com 140 mJ sem pressão pulpar simulada, enquanto que a menor média (3,90ºC) foi apresentada pelo grupo irradiado a 60 mJ com pressão pulpar simulada. Observou-se que os grupos irradiados com pressão pulpar simulada apresentaram temperaturas médias inferiores; e as médias aumentaram conforme o aumento dos parâmetros de energia do laser. Assim, concluiu-se que a variação de temperatura durante ... / Abstract: The aim of the present study was to evaluate the effects of Nd:YAG laser irradiation and simulated pulpal pressure on intrapulpal temperature. One hundred sound human molar were sectioned 1 mm below the cementoenamel junction to separate the crown and root portions. A parallel section to the occlusal surfaces exposed 2 mm thickness of dentin. The samples were divided into two groups (n=50) according to presence and absence of simulated pulpal pressure. Each group was divided into five groups (n=10) depending on the variation of Nd:YAG laser energy parameters: 60, 80, 100, 120, 140 mJ. The samples were treated with: phosphoric acid 37% (Scotchbond Universal), adhesive system (Scotchbond Universal/ 3M ESPE), irradiation with Nd:YAG laser for 60 s and light cure for 10 s. A digital thermometer was positioned in the highest pulp horn to evaluate the intrapulpal temperature. The simulated pulpal pressure was of 15 cm. For the group without simulated pulpal pressure, the pulp chamber was filled with thermal paste. Statistical analysis consisted of two-way analysis of variance (ANOVA; laser energy parameters and pulpal pressure) and Tukey's test with a significance level of 5% (p<0.05). ANOVA revealed statistically significant effect in the temperature range (p<0.05). The highest average (14.30 ºC) was observed in the group irradiated with 140 mJ without pulpal pressure simulation, while the lowest average (3.90 ºC) was observed in the group irradiated at 60 mJ with simulated pulpal pressure. It was observed that the groups treated with simulated pulpal pressure had lower temperature mean values, and the mean values increased with increasing laser energy parameters. Thus, this study concluded that the variation in temperature during laser irradiation is dependent on the energy parameters of Nd:YAG laser and intrapulpal pressure simulation / Mestre
7

O metodo do perfil termico para determinar o desempenho dos motores de tração de uma locomotiva eletrica

Cavazzoni, Fernando Arthur 20 July 2018 (has links)
Orientador: Dirk Rheinboldt / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia / Made available in DSpace on 2018-07-20T06:53:32Z (GMT). No. of bitstreams: 1 Cavazzoni_FernandoArthur_D.pdf: 3261307 bytes, checksum: e2877c7dfe6fb4bd6ce89d4b835b2345 (MD5) Previous issue date: 1975 / Resumo: A medição de temperatura em uma máquina elétrica é por si só complexa e muitas vezes controvertida, principalmente nos enrolamentos rotóricos de uma maquina de corrente continua. O Motor de Tração não somente é uma máquina elétrica de corrente continua, porém tem a agravante de sofrer um ciclo de carga não padronizado, completamente aleatório e particularmente imprevisível. A acessibilidade aos enrolamentos rotóricos de um Motor de Tração, quando instalado em uma locomotiva elétrica e praticamente impossível com a agravante que os ditos enrolamentos estão em movimento e a transferência de qualquer medida direta teria que ser transportada para fora do truque da locomotiva com elementos ou aparelhos que seguramente distorceriam a indicação inicial. Salienta-se que quaisquer dispositivos para esse fim teriam também que ser projetados para suportar impactos da ordem de 10 a 15 vezes a aceleração da gravidade. O presente trabalho apresenta o Método do Perfil Térmico para determinação de temperatura em motores de tração, principalmente da armadura, partindo de dados obtidos de testes no motor e fora da locomotiva elétrica como uma altemativa simples, prática e segura para o usuário / Abstract: Not informed / Doutorado / Doutor em Engenharia Elétrica
8

Estimativa da resistência de dossel (rc) da grama com o uso da termometria ao infravermelho / The crop canopy resistance (rc) for grass estimation using the infrared thermometer

Campeche, Luís Fernando de Souza Magno 23 January 1998 (has links)
A evapotranspiração é uma das variáveis meteorológicas mais importantes para o melhor aproveitamento do recurso hídrico. No que diz respeito ao dimensionamento e manejo de sistemas de irrigação, o conhecimento da necessidade hídrica das culturas é de fundamental importância. Assim, os estudos de técnicas que visem uma melhor estimativa desta variável, são necessários. Dos modelos matemáticos que descrevem a evapotranspiração das culturas, o proposto por Penman-Monteith é considerado um dos mais adequados, porém apresenta a limitação de usar variáveis de difícil mensuração em campo. O desenvolvimento de termômetros ao infravermelho portáteis, facilita a utilização do modelo, pois a técnica da termometria permite a estimativa dos valores de resistência de dossel, variável de maior dificuldade na determinação e de grande importância na utilização do referido modelo. Os objetivos deste trabalho foram de estimar a resistência de dossel (rc) para a cultura da grama batatais (Paspalum nolatum) pela técnica da termometria ao infravermelho e comparar com a resistência de dossel determinada como resíduo da equação de Penman-Monteith. Os valores de resistência de dossel, das variáveis meteorológicas e da evapotranspiração foram avaliados para períodos de 24 horas e períodos de luz. A análise dos resultados permitiu verificar que o valor médio da resistência de dossel (rc) determinados como resíduo, em períodos de 24 horas foi de 70,2 s.m -1. No período de luz|determinou-se um valor maior de rc, correspondente a 164 s.m-1. Os valores médios de rc estimados pela termometria ao infravermelho aumentaram com o aumento da tensão de água no solo, tanto no período de 24 horas como no período de luz / The estimation of the evapotranspiration (ET) is very important for managing water resources. The crop evapotranspiration is essential for designing and management of irrigation projects. Than, the studies of techniques that improve the estimation of ET are very necessary, despite of the enormous amount of papers already written about this subject. The Penman-Monteith model that estimates the ET crop, is very appropriate, even so it presents the limitation that the variables are not always available in the field. The development of portable infrared thermometers can help to use the modeI, once it is possible to estimate the crop canopy resistance (rc), knowing the air and crop temperature, net radiation, wind speed and the relative humidity. The rc is a variable that is very difficult to measure directly from the plants. The objective of this work were to estimate the rc for grass crop (Paspalum notatum) using the infrared thermometry technique in three different soil water tensions, and to estimate the rc values as a residue of the Penman-Monteith equation when the evapotranspiration was directly measured by a weighing lysimeter. The values of the canopy resistance, of the climatic variables, and the evapotranspiration were studied for periods of 24 hours and light periods. The analysis of the results allowed to verify that the medium value of the canopy resistance (rc) determined as residue, in periods of 24 hours it was of 70,2 s.m-1. During the light period, a larger value of rc was determined, corresponding to 164 s.m-1. The medium values of rc estimated using the infrared thermometer increased as the soil water tension increased, for both periods.
9

Estudo teórico e experimental de esforços devidos a cabos de termometria fixados em estruturas de coberturas de silos cilíndricos para armazenamento de grãos / Theoretical and experimental study of efforts due to temperature cables fixed to roof structures of cylindrical storage silos for granular products

Martins, Gisele Cristina Antunes 09 March 2012 (has links)
Um dos acidentes comuns em estruturas de armazenamento é o colapso da estrutura de cobertura do silo. Na prática, observa-se que as ruínas estruturais nesse sistema são na maior parte devidas ao desconhecimento das ações nestas estruturas. Devido à escassa informação disponível sobre os esforços de cabos de termometria fixados em estruturas de cobertura de silos cilíndricos verticais, a ênfase desta pesquisa é a análise teórica e experimental da avaliação destes esforços com o objetivo de fornecer subsídios para os projetistas e informações para uma futura normalização no dimensionamento de estruturas de cobertura para silos metálicos cilíndricos. Inicialmente realizou-se uma ampla revisão bibliográfica sobre as ações, esforços e sistemas estruturais e construtivos de cobertura para silos cilíndricos. Com base na análise teórica e experimental realizada dos esforços em cabos de termometria conclui-se que as equações propostas pela norma Argentina IRAM 8 015: 1977 são as mais adequadas para avaliação desses esforços / One of the common accidents in storage structures is the silos roof failure. In practice, it is observed that the structural problems in this system are mostly due to the lack of knowledge about the actions in these structures. Due to limited available information on temperature cables loads fixed to roof structure of vertical silos, this work has the aim in the theoretical and experimental analysis of these efforts in two different silos: the pilot-silo in LaMEM - SET - EESC-USP and silo Kepler Weber Industry, in order to provide support for designers and informations for the development of a future Brazililan Standard for the design of roof structures of cylindrical steel silos. Initially was carried out an extensive literature review on the loads, efforts and structural systems for silos roofs. The conclusions obtained from the experimental and theoretical analyzes are that the equations proposed by Argentina Standard IRAM 8015: 1977 is the most suitable for the evaluation of these loads
10

Termometria óptica remota baseada em vidros fluorofosfatos dopados com íons terras raras luminescentes / Remote optical thermometry based on fluorophosphate glasses doped with luminescent rare-earth ions

Faria, Walter José Gomes Juste 26 February 2019 (has links)
Sensores ópticos possibilitam a determinação da temperatura de maneira rápida e à distância, em ambientes onde os sensores de contato padrão se mostram ineficientes, como centrais elétricas (fortes campos eletromagnéticos), circuitos eletrônicos e células biológicas (escala micrométrica). Estes dispositivos são baseados em variações de uma propriedade óptica de um dado material devido à variação de temperatura. A técnica da razão da intensidade de fluorescência (FIR) faz uso da variação das intensidades relativas das emissões de dois níveis termicamente acoplados de um centro emissor, muitas vezes um íon terra-rara trivalente. O neodímio (Nd3+) é comumente empregado por apresentar emissões na janela biológica óptica do infravermelho próximo. Neste trabalho, vidros fluorofosfatos dopados com Nd3+ são utilizados como materiais para determinação da temperatura através da FIR. As emissões são coletadas por uma fibra óptica conectada a um espectrômetro portátil, cujos espectros medidos são analisados por um software. Este sistema permite a determinação em tempo real das razões das intensidades de fluorescência e, consequentemente, da temperatura. Sensibilidades de até 1,96%/K são obtidas para a razão entre as emissões do Nd3+ em 800 e 870 nm. Já o uso da razão entre as intensidades das emissões em 750 e 870 nm resulta em sensibilidades que chegam a 2,46%/K. A adição de itérbio (Yb3+) aos vidros faz com que a sensibilidade chegue a 2,77%/K quando emissões de ambos os íons são comparadas. O papel dos fônons na transferência de energia entre os íons é analisado. Os valores de razão de fluorescência obtidos a partir da análise pela teoria de Judd-Ofelt são aproximadamente 25% inferiores aos obtidos experimentalmente, não permitindo, neste sistema, o cálculo a priori da curva de calibração do sensor. / Optical sensors enable fast and long-distance temperature measurements in environments where standard contact sensors are ineffective, such as power stations (strong electromagnetic fields), electronic circuits and biological cells (sub-micron scale). These devices are based on temperature induced changes in optical properties of a given material. The fluorescence intensity ratio technique (FIR) makes use of the relative emission intensities variation of two thermally coupled levels of an emission center, usually a trivalent rare-earth ion. Neodymium (Nd3+) is commonly employed as its emissions lie in the near-infrared biological optical window. Here, Nd3+-doped fluorophosphate glasses are employed as a temperature sensing material through the use of FIR. The emissions are collected by an optical fiber connected to a portable spectrometer, whose measured spectra are analyzed by a software. This system enables real-time determination of the fluorescence intensity ratios and, therefore, the temperature. Sensibilities as high as 1.96%/K are obtained through the ratio between 800 and 870 nm Nd3+ emissions. The use of the emission ratio between 750 and 870 nm results in 2,46%/K sensibilities. The addition of ytterbium (Yb3+) dopant to the glasses makes the sensibilities increase to 2,77%/K when the emissions from both ions are compared. The phonons role in the energy tranfer between the ions is analyzed. The fluorescence ratio values obtained via Judd-Ofelt analysis are approximately 25% lower than the experimentally obtained, thus preventing, in this system, a priori calculation of the sensors calibration curve.

Page generated in 0.0537 seconds