• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • 1
  • Tagged with
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Procedimentos aplicaveis a garantia da qualidade metrologica dos resultados na termometria automatizada com termopar e sensores resistivos

Camarano, Denise das Merces January 1993 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina. Centro Tecnologico / Made available in DSpace on 2016-01-08T17:56:29Z (GMT). No. of bitstreams: 1 91744.pdf: 2144154 bytes, checksum: 029d24f43715c5bc058f3f0b5f52ecea (MD5) Previous issue date: 1993 / A crescente exigência em termos de qualidade implica, nas mais diversas áreas do conhecimento, a necessidade de incertezas baixas, e em especial asseguradas. Aí tem destaque o problema da medição automatizada de temperatura, frente a grande incidência prática de tal situação e a elevada importância da temperatura como parâmetro principal de interferência na maioria dos processos. São enfocados neste trabalho dois itens que se complementam dentro do contexto da obtenção de resultados com confiabilidade metrológica assegurada na termometria automatizada: a incerteza de medição global do processo de medição, incluídos os meios físicos e o concernente procedimento operacional; e, a garantia da qualidade dos instrumentos empregados na composição de cada particular sistema de medição.
2

Analysis of error in temperature measurement.

Valdir Araújo de Souza 00 December 2000 (has links)
This work presents the numerical investigation of temperature measurement error using thermocouple for different configurations utilizing a computational tool based on finite element method (Galerkin Method). The numerical code performs a two-dimensional analysis while most of the analytical models are one-dimensional. The results are then compared with the analytical, experimental and some numerical results obtained through the finite difference method. In this work five configurations are analysed: in the first configuration the error is analysed when the thermocouple is placed on a surface of a large dimensions body with an insulated wall except at the thermocouple contact region. In this configuration a technique to reduce the error in the temperature measurement is also presented. The second configuration shows the temperature measurement error when the thermocouple is embedded in a solid with constant heat flux over the opposing wall. The third configuration presents the influence of the role in a solid with a constant heat flux on the opposing surface. In the fourth configuration the temperature measurement error is investigated when the thermocouple is placed inside solids varying the depth of the thermocouple insertion for different types of materials error is analysed when a thin flat plate is surrounded either side by fluids at measurement error is analysed when a thin flat plate is surrounded either side by fluids at different temperature. The simulation were performed in a steady-state condition for all configurations and it was observed that the error is high when the thermal conductivity of the body is low and the heat transfer coefficient over the thermocouple is high. On the other hand the error is reduced when the thermocouple radius is small and also when the body dimension is large.
3

Desenvolvimento de um sistema de termometria por ultrassom para monitoramento de temperatura

Andrade, Patrícia Cardoso de 05 May 2017 (has links)
Submitted by Erika Demachki (erikademachki@gmail.com) on 2017-06-23T17:02:47Z No. of bitstreams: 2 Dissertação - Patrícia Cardoso de Andrade - 2017.pdf: 2778221 bytes, checksum: 777088966ede58904a5d760acc52b11e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2017-06-29T18:28:28Z (GMT) No. of bitstreams: 2 Dissertação - Patrícia Cardoso de Andrade - 2017.pdf: 2778221 bytes, checksum: 777088966ede58904a5d760acc52b11e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-06-29T18:28:28Z (GMT). No. of bitstreams: 2 Dissertação - Patrícia Cardoso de Andrade - 2017.pdf: 2778221 bytes, checksum: 777088966ede58904a5d760acc52b11e (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-05-05 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Measuring internal temperature and/or temperature gradient in materials is of fundamental interest in both engineering and basic sciences because the temperature is closely related to the properties of the material. The purpose of this study was to develop an ultrasound thermometry system for internal temperature gradient monitoring of materials subjected to a heat source. A low cost oscilloscope was used as a system for the acquisition of ultrasonic signals. Jointly, was developed a computational algorithm responsible for estimating the internal temperature distribution of materials. For this purpose was used a low cost oscilloscope as a system for the acquisition of ultrasonic signals. Measurements were taken during the heating and cooling regimen of an aluminum block. A thermocouple temperature measurement system was used to verify and validate the temperature distribution obtained by the ultrasound thermometry method. The development of the computational algorithm responsible for communication and data collection provided real-time temperature measurements. The comparison of the temperature measurements derived from both methods showed agreement greater than 96%, with differences lower than 0.70°C. The methodology presented was relevant within the laboratory context to estimate the internal temperature of heated materials. / Medir temperatura interna e/ou gradiente de temperatura em materiais é de fundamental interesse, tanto nas engenharias quanto nas ciências básicas, pois a temperatura está intimamente relacionada com as propriedades do material. O objetivo desse estudo foi desenvolver um sistema de termometria por ultrassom para monitoramento interno de gradiente de temperatura em materiais submetidos a fonte de calor. Conjuntamente, foi desenvolvido um algoritmo computacional responsável em estimar a distribuição de temperatura interna dos materiais. Para essa finalidade foi empregando um osciloscópio de baixo custo como sistema de aquisição de sinais ultrassônicos. Medições foram realizadas durante o regime de aquecimento e resfriamento de um bloco de alumínio. Um sistema de medição de temperatura por termopares foi utilizado para verificar e validar a distribuição de temperatura obtida pelo método de termometria por ultrassom. O desenvolvimento do algoritmo computacional responsável pela comunicação e coleta de dados propiciou medições de temperatura em tempo real. A comparação das medições de temperatura derivada de ambos os métodos apresentou concordância maior que 96%, com diferenças inferiores a 0,70°C. Portanto, conclui-se que a metodologia apresentada mostrou-se relevante dentro do contexto laboratorial para estimativa de temperatura interna de materiais aquecidos.
4

Parâmetros para o desenvolvimento de sapatilhas femininas de uso diário com ênfase no conforto térmico e percepção da usuária / Parameters for the Development of Daily Use Women Sneakers with emphasis in the Thermal Comfort and Wearer s Perception

Anselmo, Taiza Kalinowski 31 July 2014 (has links)
Made available in DSpace on 2016-12-12T20:17:55Z (GMT). No. of bitstreams: 1 118616.pdf: 3322963 bytes, checksum: 8c90d7f36cbfba744957ccedd7c6749a (MD5) Previous issue date: 2014-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Research related to the thermal comfort in shoes has been bringing substantial technological advancements to the shoe sector. The present study aims to contribute the evaluation of the thermal comfort attribute of materials used in shoe manufacturing. During this development, qualitative and quantitative techniques were applied which contributed to the evaluation of the materials studied. Two volunteers participated in the present study where they tested five similar sneakers, manufactured with different types of lining materials being laminated synthetic polyurethane with viscose substrate, polyester, viscose and polyester mix, cacharrel and leather. Evaluated points: a) volunteers perception of heat and humidity thermal evaluation and easiness of wearing in a 1 to 10 scale; b) their perception in regards to the areas which present higher variation in thermal comfort; c) feet temperature variation from thermopairs readings (Digital Thermometer TD 890 with 4 channels); d) feet thermal radiation variation using thermographic camera (Eletrophysics PV 320 model). The measurement procedures were taken during a 30 min walk at 4km/h speed. The perception, the temperature and radiation evaluation were measured before and after the 30 min. walk. The qualitative research has appointed leather as the best performance material throughout the tests. The region, which presented the highest perception in heating and humidity increase perception, was the toes region. The highest increase in temperature occurred in the Viscose lined sneaker, with a general mean percentage of 13.16% for the thermo-pairs and of 14.03% for the thermographics. Leather had the best performance with a mean percentage of approximately 1%. Despite this difference, none of the materials was considered uncomfortable according to the ABNT/NBR 14837 table of the Level of Internal Shoe Temperature Comfort. All the materials used was considered comfortable with the exception of Viscose, which was considered normal/acceptable according to the table. / A pesquisa do conforto em calçados vem proporcionando avanços tecnológicos significativos para o setor calçadista. Este estudo procurou contribuir com a avaliação de materiais usados na confecção de calçados, que promovam conforto térmico. Ao longo do desenvolvimento, foram aplicadas técnicas qualitativas e quantitativas que contribuíram na avaliação destes materiais. Participaram do estudo duas voluntárias, que testaram cinco pares de sapatilhas similares, confeccionadas com diferentes materiais no forro, laminado sintético de poliuretano com substrato em viscose, poliéster, misto (viscose e poliéster), o cacharrel e o couro. Foram avaliados: a) a percepção das voluntárias quanto à avaliação térmica de aquecimento e umidade, e calce através de uma escala com pontuação de 1 a 10; b) a percepção das regiões que apresentaram maior alteração do conforto térmico; c) registro da variação de temperatura dos pés a partir de medidas com termopares (Termômetro Digital TD 890 com 4 canais); d) registro da variação da radiação térmica do pé utilizando câmera termográfica (Eletrophysics modelo PV 320). Os procedimentos de medidas, foram conduzidos ao longo de uma caminhada de 30 min a 4 km/h. A avaliação da percepção, temperatura e radiação foram medidas antes e depois da caminhada. A pesquisa qualitativa apontou, o couro como o material que apresentou maior desempenho ao longo dos testes. A região dos pés com maior percepção de aquecimento e umidade foram os dedos. O incremento de temperatura ocorreu principalmente na sapatilha com forro viscose, com uma média percentual geral de 13,16% para os termopares e 14,03% para a termografia. O couro teve o maior desempenho, com uma média percentual aproximadamente 1%. Apesar desta diferença, nenhum material foi considerado desconfortável, de acordo com a tabela do Nível de conforto da temperatura interna do calçado ABNT/NBR 14837. Todos os materiais foram considerados confortáveis, com exceção da viscose considerada de acordo com a tabela normal.
5

Projeto e desenvolvimento de uma máquina de ensaios para argamassa expansiva. / Testing Machine for Expansive Mortar.

SILVA, Rômulo Augusto Ventura. 08 August 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-08-08T13:44:54Z No. of bitstreams: 1 RÔMULO AUGUSTO VENTURA SILVA - TESE PPGCMat 2011..pdf: 4840398 bytes, checksum: 2eaeb4106f3f72d0bc93dcad5ae11213 (MD5) / Made available in DSpace on 2018-08-08T13:44:54Z (GMT). No. of bitstreams: 1 RÔMULO AUGUSTO VENTURA SILVA - TESE PPGCMat 2011..pdf: 4840398 bytes, checksum: 2eaeb4106f3f72d0bc93dcad5ae11213 (MD5) Previous issue date: 2011-07 / A avaliação correta das propriedades de um determinado material é fundamental para que o seu desempenho atenda a todas as expectativas para as quais ele foi projetado. No decorrer do desenvolvimento de argamassa expansiva para lavra de rochas ornamentais, verificou-se a deficiência de equipamentos que pudessem avaliar a pressão e a temperatura originada por esta argamassa durante o processo de expansão. Este trabalho descreve o projeto de desenvolvimento de um equipamento para este fim. O projeto foi desenvolvido utilizando tecnologia de microcontroladores, conversores analógico-digitais do tipo SAR (successive approximation register), célula de carga do tipo S, termopares do tipo K e termistores. Em todos os itens do projeto, utilizaram-se CAD (Computer Aided Design). O armazenamento dos dados obtidos se dá em cartão de memória SD e a comunicação através de barramento USB e serial, permitindo a operação na ausência de computadores nos mais diversos ambientes com a mais ampla conectividade. Além do equipamento em si, o programa embarcado no microcontrolador e o programa de computador, responsável pela aquisição e transferência dos dados também foi desenvolvido e testado, exibindo resultados dentro dos padrões desejados. / The correct evaluation of the properties of a material is essential so that their performance meets the expectations for which it was designed. During the development of expansive mortar for mining of ornamental rocks, there was a lack of equipment that could evaluate the pressure and temperature caused by the mortar during the expansion process. This paper describes a device for this purpose. The project was developed using microcontroller technology, analogue to digital converters of the type SAR (Successive Approximation register), load cell S-type, K type thermocouples and thermistors. In all items of the project, was used CAD (Computer Aided Design). The storage of data occurs in SD memory card and communication through USB and serial bus, allowing operation in the absence of computers in various environments with the broadest connectivity. Besides the equipment itself, the program embedded in the microcontroller and the program responsible for the purchase and transfer of data was also developed and tested, showing results within the desired standards.
6

Implementación de un controlador difuso de temperatura prototipo usando la inferencia difusa de Takagi Sugeno

Huamán Bustamante, Jesús Omar January 2007 (has links)
No description available.

Page generated in 0.0507 seconds