Spelling suggestions: "subject:"deste dde resistência"" "subject:"deste dee resistência""
1 |
Estudos de técnicas de texturização e biolização, e desempenho biológico in vitro e in vivo em membrana para um dispositivo de assistência ventricular e coração artificial totalmente implantáveis / Studies of techniques applied to make a textured and biolized surface diaphragm, and biological performance in vitro and in vivo in a membrane of a ventricle assist device and total artificial heart fully implantableLegendre, Daniel Formariz 24 April 2003 (has links)
Foi desenvolvido um diafragma de elevada vida útil e biocompatibilidade a ser utilizado em um dispositivo de assistência ventricular esquerda(DAV) eletromecânico de dimensões reduzidas e totalmente implantável. Foi realizado teste de resistência do diafragma de poliuretana com superfície texturizada. O teste avaliou sua resistência para experimentos In Vivo de até quinze dias com o DAV implantado em bezerro. Uma superfície de endotélio natural tem excelente tromboresistência. A quantidade e as características da neointima formada em um DAV são determinadas pela superfície do material, hemodinâmica e condições físico-patológicas. O implante de patch na aorta abdominal de porco isola as variáveis que normalmente estão presentes durante a utilização do DAV e que interferem na hemocompatibilidade do material. A avaliação das características do material foi obtida com o seu implante na parede da aorta descendente em contato com o fluxo sanguíneo. Diferentes tipos de superfície de contato foram avaliadas em sete experimentos In Vivo. Este estudo está voltado para as reações de interface sangue / material. Um estudo histológico foi realizado ao final de cada experimento para analisar as interações entre o sangue e o material, quantificando e qualificando a intima neo formada sobre a superfície de contato, calcificação e deposições de elementos constituintes do sangue / It has been developed a high lifetime and biocompatible diaphragm to be used in a Left Ventricle Assist Device (LVAD) that is a reduced dimension totally implantable electromechanical device. It has been performed an endurance test on a textured diaphragm made of polyurethane. This test has evaluated the diaphragm resistance to be used in In Vivo tests with the LVAD implanted for fifteen days in calves. A natural endothelial cell surface has excellent thromboresistant characteristics. The quantity and the characteristics of the neointima formed into LVAD are determined by the material surface, hemodynamics of the blood through the device, and the physico-pathological conditions. The patch implantation into the abdominal aorta of pigs has isolated some normal variables that usually are present during LVAD utilization and that may interfere on the material biocompatibility. The evaluation of the materials characteristics has been enhanced through its implantation at the descending aorta wall in contact with blood flow. Different kinds of contact surfaces of specific polyurethane are tested in seven In Vivo experiments. This study is totally focused in the reaction of the blood-material interface. A histogical study is performed in the end of every animal experiment to analyze the interactions between blood and biomaterial. Its emphasized the quantification and qualification of the neointima over the blood contact surface, calcification, and blood depositions
|
2 |
Avaliação de quatro agentes cimentantes, quanto às resistências ao cisalhamento por puncionamento, à compressão axial e diametral / Evaluation of three dental cements of punch shear strength, axial compressive and diametral tensileBreno Mont\'Alverne Haddade Silva 22 May 2007 (has links)
Os agentes cimentantes são utilizados, rotineiramente, como meio de fixação para restaurações dentárias e responsáveis por preencher a interface entre o dente e uma restauração, por isso devem apresentar propriedades mecânicas satisfatórias, a fim de suportar os esforços mastigatórios e as cargas oclusais presentes no meio bucal. Sendo assim, o objetivo deste trabalho foi avaliar quatro agentes cimentantes (um fosfato de zinco, um fosfato de zinco com cobre, um ionômero de vidro e um cimento resinoso), em relação às resistências ao cisalhamento por puncionamento, à compressão axial e diametral. Para o ensaio de cisalhamento foram confeccionados espécimes em uma matriz em forma de anel com dimensões de 14 mm de diâmetro interno e 1,5 mm de altura que permitia obter um disco ou moeda dos materiais com essas dimensões a qual foi acoplada em um dispositivo próprio para o teste. Já para o ensaio de compressão axial foram seguidas as normas da \"ADA n°96\" e \"ISO 9917:1(E) cujo espécime é de formato cilíndrico com dimensões de 6 mm de altura por 4mm de diâmetro. Mesmo não apresentando normas específicas para agentes cimentantes, o ensaio de tração diametral seguiu as dimensões do espécime para o ensaio de compressão. Foram confeccionados 10 espécimes de cada material para os respectivos ensaios, analisados nos períodos de 1 e 24 horas. Os resultados foram tratados estatisticamente com a Análise de Variância a dois critérios (ANOVA), seguido do teste comparativo de tukey com p < 0,05. O agente cimentante que apresentou os valores mais altos de resistência foi o cimento resinoso para os três testes realizados e o cimento de ionômero de vidro apresentou os valores mais baixos de resistência dentre todos os materiais analisados, juntamente com os diferentes períodos. / The dental cements are used, routinely, to fixation of restorative dental and responsible for filling the interface between the tooth and a restoration, therefore they must present satisfactory mechanical properties, in order to support the masticatory forces and occlusal loads in the oral cavity. Being thus, the objective of this work was to evaluate four dental cements (a phosphate zinc, a red copper phosphate zinc, a glass-ionomer and a resin cement), in relation to the punch shear strength, axial and diametral compression strength. For the punch shear assay, had been made specimens in a matrix in ring form with dimensions of 14mm of internal diameter and 1,5 mm of height that allowed to get a disc or currency of the materials with these dimensions which was connected in a proper device for the test. For the axial compressive assay had been followed the specifications of \"ADA n°96\" and \"ISO 9917:1(E)\" whose specimen is of cylindrical format with dimensions of 6 mm of height for 4 mm of diameter. The tensile diametral assay, not exactly presenting specific norms for dental cements, followed the dimensions of the specimen for the axial compressive assay. Ten specimens of each material for the respective assays, analyzed in the periods of 1 and 24 hours had been made. The results were statistically analyzed with the two-way ANOVA, followed of the comparative tukey test with p< 0,05 The dental cement who obtained the highest values of strength was the resin cement for the three tests and the glass-ionomer cement obtained the lowest values of strength among all the materials and different periods.
|
3 |
Estudos de técnicas de texturização e biolização, e desempenho biológico in vitro e in vivo em membrana para um dispositivo de assistência ventricular e coração artificial totalmente implantáveis / Studies of techniques applied to make a textured and biolized surface diaphragm, and biological performance in vitro and in vivo in a membrane of a ventricle assist device and total artificial heart fully implantableDaniel Formariz Legendre 24 April 2003 (has links)
Foi desenvolvido um diafragma de elevada vida útil e biocompatibilidade a ser utilizado em um dispositivo de assistência ventricular esquerda(DAV) eletromecânico de dimensões reduzidas e totalmente implantável. Foi realizado teste de resistência do diafragma de poliuretana com superfície texturizada. O teste avaliou sua resistência para experimentos In Vivo de até quinze dias com o DAV implantado em bezerro. Uma superfície de endotélio natural tem excelente tromboresistência. A quantidade e as características da neointima formada em um DAV são determinadas pela superfície do material, hemodinâmica e condições físico-patológicas. O implante de patch na aorta abdominal de porco isola as variáveis que normalmente estão presentes durante a utilização do DAV e que interferem na hemocompatibilidade do material. A avaliação das características do material foi obtida com o seu implante na parede da aorta descendente em contato com o fluxo sanguíneo. Diferentes tipos de superfície de contato foram avaliadas em sete experimentos In Vivo. Este estudo está voltado para as reações de interface sangue / material. Um estudo histológico foi realizado ao final de cada experimento para analisar as interações entre o sangue e o material, quantificando e qualificando a intima neo formada sobre a superfície de contato, calcificação e deposições de elementos constituintes do sangue / It has been developed a high lifetime and biocompatible diaphragm to be used in a Left Ventricle Assist Device (LVAD) that is a reduced dimension totally implantable electromechanical device. It has been performed an endurance test on a textured diaphragm made of polyurethane. This test has evaluated the diaphragm resistance to be used in In Vivo tests with the LVAD implanted for fifteen days in calves. A natural endothelial cell surface has excellent thromboresistant characteristics. The quantity and the characteristics of the neointima formed into LVAD are determined by the material surface, hemodynamics of the blood through the device, and the physico-pathological conditions. The patch implantation into the abdominal aorta of pigs has isolated some normal variables that usually are present during LVAD utilization and that may interfere on the material biocompatibility. The evaluation of the materials characteristics has been enhanced through its implantation at the descending aorta wall in contact with blood flow. Different kinds of contact surfaces of specific polyurethane are tested in seven In Vivo experiments. This study is totally focused in the reaction of the blood-material interface. A histogical study is performed in the end of every animal experiment to analyze the interactions between blood and biomaterial. Its emphasized the quantification and qualification of the neointima over the blood contact surface, calcification, and blood depositions
|
4 |
Avaliação de quatro agentes cimentantes, quanto às resistências ao cisalhamento por puncionamento, à compressão axial e diametral / Evaluation of three dental cements of punch shear strength, axial compressive and diametral tensileSilva, Breno Mont\'Alverne Haddade 22 May 2007 (has links)
Os agentes cimentantes são utilizados, rotineiramente, como meio de fixação para restaurações dentárias e responsáveis por preencher a interface entre o dente e uma restauração, por isso devem apresentar propriedades mecânicas satisfatórias, a fim de suportar os esforços mastigatórios e as cargas oclusais presentes no meio bucal. Sendo assim, o objetivo deste trabalho foi avaliar quatro agentes cimentantes (um fosfato de zinco, um fosfato de zinco com cobre, um ionômero de vidro e um cimento resinoso), em relação às resistências ao cisalhamento por puncionamento, à compressão axial e diametral. Para o ensaio de cisalhamento foram confeccionados espécimes em uma matriz em forma de anel com dimensões de 14 mm de diâmetro interno e 1,5 mm de altura que permitia obter um disco ou moeda dos materiais com essas dimensões a qual foi acoplada em um dispositivo próprio para o teste. Já para o ensaio de compressão axial foram seguidas as normas da \"ADA n°96\" e \"ISO 9917:1(E) cujo espécime é de formato cilíndrico com dimensões de 6 mm de altura por 4mm de diâmetro. Mesmo não apresentando normas específicas para agentes cimentantes, o ensaio de tração diametral seguiu as dimensões do espécime para o ensaio de compressão. Foram confeccionados 10 espécimes de cada material para os respectivos ensaios, analisados nos períodos de 1 e 24 horas. Os resultados foram tratados estatisticamente com a Análise de Variância a dois critérios (ANOVA), seguido do teste comparativo de tukey com p < 0,05. O agente cimentante que apresentou os valores mais altos de resistência foi o cimento resinoso para os três testes realizados e o cimento de ionômero de vidro apresentou os valores mais baixos de resistência dentre todos os materiais analisados, juntamente com os diferentes períodos. / The dental cements are used, routinely, to fixation of restorative dental and responsible for filling the interface between the tooth and a restoration, therefore they must present satisfactory mechanical properties, in order to support the masticatory forces and occlusal loads in the oral cavity. Being thus, the objective of this work was to evaluate four dental cements (a phosphate zinc, a red copper phosphate zinc, a glass-ionomer and a resin cement), in relation to the punch shear strength, axial and diametral compression strength. For the punch shear assay, had been made specimens in a matrix in ring form with dimensions of 14mm of internal diameter and 1,5 mm of height that allowed to get a disc or currency of the materials with these dimensions which was connected in a proper device for the test. For the axial compressive assay had been followed the specifications of \"ADA n°96\" and \"ISO 9917:1(E)\" whose specimen is of cylindrical format with dimensions of 6 mm of height for 4 mm of diameter. The tensile diametral assay, not exactly presenting specific norms for dental cements, followed the dimensions of the specimen for the axial compressive assay. Ten specimens of each material for the respective assays, analyzed in the periods of 1 and 24 hours had been made. The results were statistically analyzed with the two-way ANOVA, followed of the comparative tukey test with p< 0,05 The dental cement who obtained the highest values of strength was the resin cement for the three tests and the glass-ionomer cement obtained the lowest values of strength among all the materials and different periods.
|
5 |
Prevalência das mutações de resistência a drogas (DRM) antirretrovirais em pacientes soropositivos para o HIV do ambulatório de Imunodeficiências Secundárias do HCFMUSP na cidade de São Paulo, Brasil / Prevalence of antiretroviral drug resistance mutations (DRM) in HIV seropositive patients from the outpatient clinic of a large university from São Paulo, BrazilOliveira, Ericka Constantinov 01 July 2019 (has links)
Apesar dos avanços nas últimas décadas no tratamento do paciente soropositivo para o HIV e da recomendação de 2015 da Organização Mundial de Saúde (OMS), ainda permanece o obstáculo das Mutações de Resistência a Drogas (DRMs) do vírus, induzida por suas altas taxas de mutação, que pode prejudicar o sucesso da terapia e comprometer a prevenção da doença, limitando as opções de tratamento disponíveis. Vários estudos em diferentes partes do mundo têm demonstrado aumento ou taxas estáveis de resistência aos antirretrovirais (ARVs), por isso, é necessário o monitoramento dessas DRMs, que terão suas particularidades de acordo com o perfil de cada região. Com esse propósito, este estudo avaliou as DRMs e sua suscetibilidade às principais classes de ARVs nos pacientes soropositivos para o HIV do Hospital das Clinicas da cidade de São Paulo. Para os pacientes nunca expostos ao tratamento ARV, a prevalência de DRMs transmitidas das 249 genotipagens analisadas foi de 21 (8,4%) e a prevalência de DRMs adquiridas foi de 75 (68,8%) dos 109 casos expostos ao ARV. Além disso, na comparação dessa prevalência entre as duas décadas de abrangência deste estudo (2002-2017), houve aumento de qualquer mutação CPR (Calibração de Resistência Populacional), transmitida, da primeira para a segunda década, principalmente da classe NNRTI (Inibidores Não Nucleosídios da Transcriptase Reversa). Também é importante destacar que as mutações transmitidas responsáveis por esse aumento foram a K103N (3,5%), a P225H (0,6%) e K103S e Y181C, ambos com 0,3%. Já para o grupo dos pacientes em uso das medicações ARVs, houve uma pequena diminuição, não significativa, de qualquer mutação da primeira para a segunda década, porém, somente da classe IP (Inibidores da Protease), isoladamente, que foi significativo essa diminuição / Despite the progress in recent decades of HIV patient treatment and the 2015 Recommendation of the World Health Organization (WHO), it still remains an obstacle, the virus Drug Resistance Mutations (DRMs) induced by their high mutation rates, which may affect the success of the therapy and compromise the prevention of the disease, limiting treatment options available. Many studies in different parts of the world demonstrate an increase or even steady rates of resistance to antiretroviral (arv) drugs, therefore, it´s necessary to monitor these DRMs, which will have their own peculiarities according to each region. For this purpose, this study evaluated the DRMs and their susceptibility to the main classes of antiretrovirus present in the HIV patients at the Hospital das Clínicas in São Paulo. To patients never exposed to antiretrovirus treatment, the prevalence of transmitted DRMs was 21 (8.4%) of 249 genotypes analysed and the prevalence of acquired DRMs was 75 (68.8%) of 109 cases exposed to arv. In adittion to it, the comparison of this prevalence in almost two decades of study (2002-2017), shows an increase of any mutation CPR (Calibrated Population Resistance) transmitted from the first to the second decade mainly of NNRTI (Non-Nucleoside Reverse Transcriptase Inhibitors) class. Alongside this, it´s important to note that the transmitted mutations responsible to this increase were K103N (3.5%), P225H (0.6%) and K103S and Y181C, both with 0.3%. Considering the group of pacients in use of arv drugs, there were found a non-significant small decrease of any mutation from the first decade to the second, although only IP (Protease Inhibitors) class showed a significant decrease
|
6 |
Qualidade dos couros de tilápia, corvina e pescada amarela / Quality of leather of tilapia, corvina e pescada amarelaCorrêa, Stefane Santos 24 March 2017 (has links)
Submitted by Marilene Donadel (marilene.donadel@unioeste.br) on 2017-11-08T23:52:44Z
No. of bitstreams: 1
Stefane_S_Corrêa_2017.pdf: 1344962 bytes, checksum: 2369f5181c7145ed68be3f6f7181b3f8 (MD5) / Made available in DSpace on 2017-11-08T23:52:44Z (GMT). No. of bitstreams: 1
Stefane_S_Corrêa_2017.pdf: 1344962 bytes, checksum: 2369f5181c7145ed68be3f6f7181b3f8 (MD5)
Previous issue date: 2017-03-24 / The leather tanning of fish is a way of alleviating the damage caused by chromium salts to the environment. this work had as objective evaluate the process of tanning leather in the skins in corvina and pescada amarela from fishing made in the northern region of Brasil and tilápia origin of fish farming. The species caught in the fishing of the region present the potential for use in the tanning because they are large, which allows you to add value to the final product. The skins were to the same tanning process not differing in any of its stages. to determine the efficiency of the process, the skins of corvina, pescada amarela and tilapia were submitted to the resistence test the traction, stretching and progressive tear in the longitudinal and transverse directions of the body of the fish and the physical-chemical analysis. the resistance tests the traction and stretching were satisfactory for manufacturing of products and clothing. However, suggests improve the grease of the tanning process. / O curtimento vegetal de couro de peixes é uma forma de amenizar os danos causados pelos sais de cromo ao ambiente. Este trabalho teve como objetivo avaliar o processo de curtimento nas peles de corvina e pescada amarela oriundas da pesca realizadas na região norte e tilápia oriunda de piscicultura do estado do Paraná. As peles foram submetidas ao mesmo processo de curtimento vegetal não diferindo em nenhuma das suas etapas. Para determinar a eficiência do processo, as peles de corvina, pescada amarela e tilápia foram submetidas à análise físico-química, ao teste de resistência à tração, alongamento e rasgamento progressivo no sentido longitudinal e transversal do corpo do peixe. Foi realizada a analise histológica dos couros, para se analisar a estrutura das fibras. Os testes de resistência à tração e alongamento foram satisfatórios, comprovando que as peles das espécies capturadas na pesca da região norte do Brasil apresentam potencial para utilização no curtimento, apresentando qualidade apropriada para confecção de produto, vestuário e calçado. Entretanto, sugere-se aprimorar a etapa de engraxe do processo de curtimento.
|
7 |
Forças, momentos e coeficiente de atrito em teste de três pontos e em teste de resistência ao deslizamento com braquetes autoligáveis e fios 0.014\" utilizando um novo dispositivo / Forces, moments and coefficient of friction in three-bracket bending test and in resistance to sliding test with self-ligating brackets and wires 0.014\'\' using a new deviceFreitas, Ana Carolina Carneiro de 26 January 2016 (has links)
O objetivo principal do estudo é comparar o teste em 3 pontos com braquetes com o teste de resistência ao deslizamento utilizando um novo dispositivo que realiza a mensuração simultânea do coeficiente de atrito, das forças e dos momentos nos braquetes de ancoragem e da força de desativação no braquete desalinhado, exercidos por fios ortodônticos. Os objetivos secundários foram desenvolver o dispositivo e comparar, no teste em 3 pontos: (i) a influência, nas grandezas e no coeficiente de atrito cinético, da variação da simetria nas distâncias inter-braquetes, do tipo de braquete de ancoragem (canino ou 2º pré-molar), do deslocamento (3 ou 5mm) do braquete central, do sentido do desalinhamento (vestibular ou lingual) do braquete central e da marca de fio-braquete; (ii) as 3 formas de cálculo do coeficiente de atrito cinético; (iii) os 10 ciclos, para vestibular ou lingual, para verificar se eles são semelhantes ou não entre si. Foram utilizados braquetes autoligáveis (dentes 13, 14 e 15) e fios 0.014\'\' NiTi e CuNiTi das marcas Aditek e Ormco. O teste de resistência ao deslizamento foi realizado no desalinhamento lingual, nos dois deslocamentos e na configuração simétrica. O teste em 3 pontos com braquetes foi realizado no desalinhamento lingual e vestibular, nos dois deslocamentos e na configuração simétrica e assimétrica. Por meio da ANOVA, foram comparados, entre os dois tipos de teste: (A) as grandezas e o coeficiente de atrito e (B) o coeficiente de atrito gerado apenas no braquete de 2º pré-molar. Utilizando-se do mesmo teste estatístico foram comparados, no teste em 3 pontos com braquetes: (A) na configuração simétrica, algumas grandezas e o coeficiente de atrito advindos da variação da marca de fio-braquete, do deslocamento, do desalinhamento e do tipo de braquete; (B) algumas grandezas e o coeficiente de atrito gerados na configuração simétrica e assimétrica; (C) os valores das 3 formas de cálculo do coeficiente de atrito na configuração simétrica; e (D) algumas grandezas e o coeficiente de atrito encontrados nos 10 ciclos. Resultados: (A) a maioria dos valores das grandezas e do coeficiente de atrito gerados pelos dois tipos de teste foram diferentes estatisticamente; (B) o braquete de 2º pré-molar apresentou valores de coeficiente de atrito diferentes entre os dois tipos de teste; (C) na configuração simétrica, as variáveis foram estatisticamente significantes na maioria dos casos para as grandezas analisadas e para o coeficiente de atrito; (D) houve diferença entre a configuração simétrica e assimétrica; (E) o coeficiente de atrito baseado nas duas normais e na força de atrito se aproximou mais da realidade clínica e foi sensível à variação da geometria da relação fio-braquete; e (F) os 10 ciclos para lingual foram semelhantes entre si em 70% dos casos e os 10 ciclos para vestibular foram diferentes em 57% dos casos. Conclusões: o teste em 3 pontos com braquetes é diferente do teste de resistência ao deslizamento; a variação das configurações geométricas e da marca de fio-braquete pode influenciar nos valores das grandezas e do coeficiente de atrito cinético; os 10 ciclos para lingual foram mais semelhantes entre si que os 10 ciclos para vestibular. / The main objective of the study is to compare the three-bracket bending test with the resistance to sliding test using a new device that performs simultaneous measurement of coefficient of friction, the forces and moments on the anchor brackets and deactivation force in misaligned bracket, exercised by orthodontic wires. Secondary objectives were to develop the device and compare, in the three-bracket bending test: (i) the influence, on the physical quantities and on the kinetic friction coefficient, of the variation of the symmetry in the inter-bracket distance, of the type of anchor bracket (canine or 2nd premolar), of displacement (3 or 5mm) and misalignment (buccal or lingual) of the central bracket, and of the wire and bracket brand; (ii) the three ways to calculate the coefficient of kinetic friction; (iii) the 10 cycles, for buccal or lingual, to see if they are similar or not. Self-ligating brackets were used (teeth 13, 14 and 15) and wires 0.014 \'\' NiTi and CuNiTi of Aditek and Ormco brands. The resistance to sliding test was conducted on the lingual misalignment, on both displacements and on symmetrical configuration. The three-bracket bending test was held at the lingual and vestibular misalignment, at both displacements and at the symmetrical and asymmetrical configuration. Through ANOVA, were compared, between the two types of tests: (A) the quantities and the coefficient of friction and (B) the coefficient of friction generated only in the second premolar bracket. Using the same statistical test were compared, in three-bracket bending test: (A) in symmetrical configuration, the quantities and the coefficient of friction arising from the variation in the wire and bracket brands, displacement, misalignment and the type of bracket; (B) the quantities and the coefficient of friction generated by the symmetric and asymmetric configuration; (C) the values of the three ways of calculating friction coefficient; and (D) the quantities and the coefficient of friction encountered in 10 cycles. Results: (A) most of the values of the quantities and the coefficient of friction generated by the two types of test were statistically different; (B) the 2nd premolar bracket showed different friction coefficient values between the two types of test; (C) in the symmetrical configuration, the variables were statistically significant in the most of cases for quantities and the friction coefficient; (D) was found difference between symmetric and asymmetric configuration; (E) the friction coefficient based on both normal forces and frictional force was closer to the clinical reality and was sensitive to variations in the geometry of the wire-bracket relationship; and (F) the 10 cycles for lingual were similar in 70% of cases and the 10 cycles for buccal desalignment were different in 57% of cases. Conclusions: The three-bracket bending test is different from the resistance to sliding test; the variation of geometric configurations and wire and bracket brands may influence the values of the quantities and the coefficient of kinetic friction; the 10 cycles for lingual were more similar to each other than the 10 cycles for buccal.
|
8 |
Forças, momentos e coeficiente de atrito em teste de três pontos e em teste de resistência ao deslizamento com braquetes autoligáveis e fios 0.014\" utilizando um novo dispositivo / Forces, moments and coefficient of friction in three-bracket bending test and in resistance to sliding test with self-ligating brackets and wires 0.014\'\' using a new deviceAna Carolina Carneiro de Freitas 26 January 2016 (has links)
O objetivo principal do estudo é comparar o teste em 3 pontos com braquetes com o teste de resistência ao deslizamento utilizando um novo dispositivo que realiza a mensuração simultânea do coeficiente de atrito, das forças e dos momentos nos braquetes de ancoragem e da força de desativação no braquete desalinhado, exercidos por fios ortodônticos. Os objetivos secundários foram desenvolver o dispositivo e comparar, no teste em 3 pontos: (i) a influência, nas grandezas e no coeficiente de atrito cinético, da variação da simetria nas distâncias inter-braquetes, do tipo de braquete de ancoragem (canino ou 2º pré-molar), do deslocamento (3 ou 5mm) do braquete central, do sentido do desalinhamento (vestibular ou lingual) do braquete central e da marca de fio-braquete; (ii) as 3 formas de cálculo do coeficiente de atrito cinético; (iii) os 10 ciclos, para vestibular ou lingual, para verificar se eles são semelhantes ou não entre si. Foram utilizados braquetes autoligáveis (dentes 13, 14 e 15) e fios 0.014\'\' NiTi e CuNiTi das marcas Aditek e Ormco. O teste de resistência ao deslizamento foi realizado no desalinhamento lingual, nos dois deslocamentos e na configuração simétrica. O teste em 3 pontos com braquetes foi realizado no desalinhamento lingual e vestibular, nos dois deslocamentos e na configuração simétrica e assimétrica. Por meio da ANOVA, foram comparados, entre os dois tipos de teste: (A) as grandezas e o coeficiente de atrito e (B) o coeficiente de atrito gerado apenas no braquete de 2º pré-molar. Utilizando-se do mesmo teste estatístico foram comparados, no teste em 3 pontos com braquetes: (A) na configuração simétrica, algumas grandezas e o coeficiente de atrito advindos da variação da marca de fio-braquete, do deslocamento, do desalinhamento e do tipo de braquete; (B) algumas grandezas e o coeficiente de atrito gerados na configuração simétrica e assimétrica; (C) os valores das 3 formas de cálculo do coeficiente de atrito na configuração simétrica; e (D) algumas grandezas e o coeficiente de atrito encontrados nos 10 ciclos. Resultados: (A) a maioria dos valores das grandezas e do coeficiente de atrito gerados pelos dois tipos de teste foram diferentes estatisticamente; (B) o braquete de 2º pré-molar apresentou valores de coeficiente de atrito diferentes entre os dois tipos de teste; (C) na configuração simétrica, as variáveis foram estatisticamente significantes na maioria dos casos para as grandezas analisadas e para o coeficiente de atrito; (D) houve diferença entre a configuração simétrica e assimétrica; (E) o coeficiente de atrito baseado nas duas normais e na força de atrito se aproximou mais da realidade clínica e foi sensível à variação da geometria da relação fio-braquete; e (F) os 10 ciclos para lingual foram semelhantes entre si em 70% dos casos e os 10 ciclos para vestibular foram diferentes em 57% dos casos. Conclusões: o teste em 3 pontos com braquetes é diferente do teste de resistência ao deslizamento; a variação das configurações geométricas e da marca de fio-braquete pode influenciar nos valores das grandezas e do coeficiente de atrito cinético; os 10 ciclos para lingual foram mais semelhantes entre si que os 10 ciclos para vestibular. / The main objective of the study is to compare the three-bracket bending test with the resistance to sliding test using a new device that performs simultaneous measurement of coefficient of friction, the forces and moments on the anchor brackets and deactivation force in misaligned bracket, exercised by orthodontic wires. Secondary objectives were to develop the device and compare, in the three-bracket bending test: (i) the influence, on the physical quantities and on the kinetic friction coefficient, of the variation of the symmetry in the inter-bracket distance, of the type of anchor bracket (canine or 2nd premolar), of displacement (3 or 5mm) and misalignment (buccal or lingual) of the central bracket, and of the wire and bracket brand; (ii) the three ways to calculate the coefficient of kinetic friction; (iii) the 10 cycles, for buccal or lingual, to see if they are similar or not. Self-ligating brackets were used (teeth 13, 14 and 15) and wires 0.014 \'\' NiTi and CuNiTi of Aditek and Ormco brands. The resistance to sliding test was conducted on the lingual misalignment, on both displacements and on symmetrical configuration. The three-bracket bending test was held at the lingual and vestibular misalignment, at both displacements and at the symmetrical and asymmetrical configuration. Through ANOVA, were compared, between the two types of tests: (A) the quantities and the coefficient of friction and (B) the coefficient of friction generated only in the second premolar bracket. Using the same statistical test were compared, in three-bracket bending test: (A) in symmetrical configuration, the quantities and the coefficient of friction arising from the variation in the wire and bracket brands, displacement, misalignment and the type of bracket; (B) the quantities and the coefficient of friction generated by the symmetric and asymmetric configuration; (C) the values of the three ways of calculating friction coefficient; and (D) the quantities and the coefficient of friction encountered in 10 cycles. Results: (A) most of the values of the quantities and the coefficient of friction generated by the two types of test were statistically different; (B) the 2nd premolar bracket showed different friction coefficient values between the two types of test; (C) in the symmetrical configuration, the variables were statistically significant in the most of cases for quantities and the friction coefficient; (D) was found difference between symmetric and asymmetric configuration; (E) the friction coefficient based on both normal forces and frictional force was closer to the clinical reality and was sensitive to variations in the geometry of the wire-bracket relationship; and (F) the 10 cycles for lingual were similar in 70% of cases and the 10 cycles for buccal desalignment were different in 57% of cases. Conclusions: The three-bracket bending test is different from the resistance to sliding test; the variation of geometric configurations and wire and bracket brands may influence the values of the quantities and the coefficient of kinetic friction; the 10 cycles for lingual were more similar to each other than the 10 cycles for buccal.
|
Page generated in 0.0854 seconds