• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ligaduras ortodônticas elastoméricas estéticas: quantificação de endotoxina bacteriana in vitro e in vivo / Orthodontic elastomeric aesthetic ligatures: quantification of bacterial endotoxin in vitro and in vivo

Pinto, Letícia Sgarbi 11 May 2018 (has links)
O objetivo do presente trabalho foi quantificar, in vitro e in vivo, a endotoxina bacteriana (LPS) aderida a ligaduras ortodônticas elastoméricas estéticas de poliuretano e de silicone, empregando o teste Limulus Amebocyte Lysate (LAL). Para o estudo in vitro foram utilizadas quatro tipos de ligaduras elastoméricas estéticas: Sani-Ties (poliuretano) e Sili-Ties (silicone), da GAC, e Mini Single Case Ligature Stick (poliuretano) e Synergy&reg; Low-friction ligatures (silicone), da Rock Mountain, sendo 5 contaminadas com solução de endotoxina (controle positivo) e 5 não-contaminadas (controle negativo). Réplicas feitas de fio de amarrilho torcido e de aço inox fundido, de mesmo tamanho e formato das ligaduras elastoméricas, contaminadas ou não com endotoxina, foram usadas como controle. A quantificação de endotoxina foi realizada por meio do teste LAL (Kit QCL-1000&trade;), sendo os resultados expressos em unidades de endotoxina (UE/mL). No estudo in vivo, 20 pacientes de ambos os gêneros, com faixa etária entre 15 e 30 anos, que iniciaram tratamento com aparelho ortodôntico fixo na Faculdade de Odontologia de Ribeirão Preto - Universidade de São Paulo receberam, randomicamente, em quadrantes alternados, os mesmos quatro tipos de ligaduras elastoméricas utilizadas no estudo in vitro, sendo uma ligadura de cada marca inserida nos caninos superiores e inferiores (13, 23, 33 e 43), aleatoriamente. Vinte e um dias após, as ligaduras foram removidas e processadas para quantificação da endotoxina bacteriana, utilizando também o Kit QCL-1000&trade;. Todos os dados obtidos foram submetidos à análise estatística apropriada de acordo com a distribuição dos dados, por meio dos testes de Kruskal-Wallis e pós-teste de Dunn (estudo in vitro) e ANOVA de medidas repetidas e pós-teste de Tukey (estudo in vivo). Todas as análises foram efetuadas por meio do programa Graph Pad Prism 4.0, com nível de significância de 5%. De acordo com os resultados obtidos, observou-se que a endotoxina bacteriana aderiu-se a todos os materiais testados. No estudo in vitro, o grupo GAC silicone foi o que apresentou menor mediana de contaminação (1,15 UE/mL), com relação aos outros grupos (p<0,0001), os quais não apresentaram diferença estatisticamente significante quando comparados entre si (p>0,05). No estudo in vivo, de maneira semelhante ao observado no estudo in vitro, o grupo GAC silicone foi o que apresentou menor média de contaminação (0,577±0,017 UE/mL), com diferença estatisticamente significante (p<0,001) em comparação aos demais grupos. Pôde-se concluir, que a endotoxina bacteriana apresentou afinidade pelas ligaduras elastoméricas estéticas à base de silicone e poliuretano testadas. As ligaduras de silicone da marca GAC foram as que apresentaram menor quantidade de endotoxina aderida às suas superfícies / The objective of this study was to quantify, in vitro and in vivo, bacterial endotoxin (LPS) attached to esthetic elastomeric orthodontic ligatures made of polyurethane and silicone using the Limulus Amebocyte Lysate test (LAL). For the in vitro study, were used four types of aesthetic elastomeric ligatures: Sani-Ties (polyurethane) and Sili-Ties (silicone) - GAC, and Mini Single Case Ligature Stick (polyurethane) and Synergy&reg; Low-friction ligatures (silicone) - Rock Mountain; 5 of each were contaminated with endotoxin solution (positive control) and 5 non-contaminated (negative control). Replicas made of twisted wire ligatures and of cast stainless steel, of the same size and shape than the elastomeric ligatures, contaminated or not with endotoxin, were used as control. Endotoxin quantification was performed using the LAL test (QCL-1000&trade; kit), the results being expressed in EU/mL. In the in vivo study, 20 patients of both genders, with ages ranging from 15 to 30 years old, who started treatment with a fixed orthodontic appliance at the School of Dentistry of Ribeirão Preto - University of São Paulo, received randomly the same four types of elastomeric ligatures used in the in vitro study, being a ligature of each brand inserted in the upper and lower canines (UR3, UL3, LR3, LL3), randomly. Twenty-one days later, ligatures were removed and processed for quantification of bacterial endotoxin, using the same test as the in vitro study. All data were submitted to appropriate statistical analysis according to the data distribution, using KruskalWallis tests and Dunn post-test (in vitro study) and ANOVA of repeated measurements and Tukey\'s post-test (in vivo study). All analyzes were performed using the Graph Pad Prism 4.0 program, with a significance level of 5%. According to the results obtained, it was observed that the bacterial endotoxin attached to all materials tested. In the in vitro study, the GAC silicone group had the lowest median contamination (1.15 EU/mL), in relation to the other groups (p<0.0001), which did not present a statistically significant difference when compared to each other (p>0.05). In the in vivo study, similar to that observed in the in vitro study, the GAC silicone group had the lowest mean contamination (0.577 ± 0.017 EU/mL), with a statistically significant difference (p< 0.001) compared to the others groups. It could be concluded that bacterial endotoxin exhibited affinity for the tested silicone and polyurethane aesthetic elastomeric ligatures. The silicone ligatures of GAC brand were the ones that presented less amount of endotoxin attached to their surfaces
2

Avaliação do Teste de Ativação de Monócitos na determinação da contaminação pirogênica com ácido lipoteicóico em produtos injetáveis / Evaluation of Monocyte Activation Test in determining pyrogenic contamination with lipoteichoic acid in injectable products

Lopes, Izabela Gimenes January 2014 (has links)
Submitted by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2014-08-01T12:58:03Z No. of bitstreams: 1 Dissertação Izabela.pdf: 1302143 bytes, checksum: ab457123bfc94643d499a3062e8b2cc2 (MD5) / Made available in DSpace on 2014-08-01T12:58:03Z (GMT). No. of bitstreams: 1 Dissertação Izabela.pdf: 1302143 bytes, checksum: ab457123bfc94643d499a3062e8b2cc2 (MD5) Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / O teste de detecção de pirogênio é preconizado nas farmacopeias como teste de segurança imprescindível para a avaliação da qualidade de produtos injetáveis. Os métodos alternativos ao teste de pirogênio em coelhos são o Teste de Lisado de Amebócitos de Limulus (LAL) e o Teste de Ativação de Monócitos (MAT). Esses métodos ainda não podem substituir o teste em coelhos por completo, pois no caso do LAL os resultados podem não ser confiáveis quando a análise é realizada na presença de algumas substâncias interferentes com alto teor de lipídios e proteínas (encontrados nos medicamentos biológicos) e glucanas, além disso, o teste só detecta endotoxinas. Em relação ao MAT, já que o teste é sensível para todos os tipos de pirogênios e tem o mesmo mecanismo biológico responsável pela reação de febre em humanos, o Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) recomendou sua utilização desde que fique demonstrada a equivalência de seus resultados ao teste em coelhos, em conformidade com a regulamentação aplicável. Verifica-se assim, que a literatura carece de dados que envolvam a comparação entre a dose limite que causa febre em coelhos e a correspondência para o MAT relacionado ao ácido lipoteicóico (ALT), sendo assim, esse estudo tem como objetivo principal avaliar a utilização do MAT na detecção da contaminação de ALT de S. aureus em Cloreto de Sódio 0,9 % apirogênico artificialmente contaminado, através do estabelecimento de curva dose-resposta de ALT em coelhos; curva concentração-resposta de ALT para o MAT e avaliação em paralelo dos resultados obtidos utilizando ALT no teste em coelhos, LAL cromogênico e MAT. A resposta de febre foi observada a partir de 75.000 ng de ALT/Kg nos coelhos e no MAT para sangue criopreservado/IL-1β foi estabelecida em 50.000 ng/mL de ALT, ou 5,41 UEE/mL. O teste de LAL apresentou resultado falso-reativo a partir de 10.000 ng/mL de ALT. Os resultados apresentados neste estudo fornecem informações importantes sobre a comparação entre o teste de pirogênio em coelhos, MAT e LAL, contribuindo com dados para a validação do MAT, envolvendo outros pirogênios que não a endotoxina, e também para a aceitação deste teste pelos órgãos regulatórios no Brasil visando uma possível substituição do uso de animais, garantindo, assim, a segurança da saúde da população. / The pyrogenic test is preconized in the Pharmacopeias as a safety test indispensable for the quality of evaluation of injectable products. The alternative methods to the rabbit pyrogen test are the Limulus Amebocite Lysate (LAL) Test and the Monocyte Activation Test (MAT). These methods cannot replace the rabbit test completely yet, for in the case of LAL the results may not be reliable when the analysis is carried out in the presence of some interfering substances with high content of lipids and proteins (found in biological medicines) and glucans, moreover, the test only detects endotoxins. Concerning the MAT, since the test is sensitive to all types of pyrogens and has the same biological mechanism responsible for the fever reaction in humans, the Interagency Coordinating Committee on the Validation of Alternative Methods (Comitê de Coordenação Interagências sobre Validação de Métodos Alternativos - ICCVAM) have recommended its utilization provided that the equivalence of its results from the rabbit test, in conformity with the applicable regulation. It can be verified, then, that the literature lacks the data which involves the comparison between the limit dose that causes fever in rabbits and the consequence for the MAT related to the lipoteichoic acid (LTA), that being so, the aim of this study is mainly the utilization of MAT in the detection of the contamination of LTA of S. aureus in apyrogenic 0.9 % Sodium Chloride artificially contaminated, through the establishment of the dose-response curve of LTA in rabbits; concentration-response curve of LTA for the MAT and parallel evaluation of the results obtained by utilizing LTA in the test in rabbits, chromogenic LAL and MAT. The fever response was observed from 75.000 ng of LTA/Kg in rabbits and in MAT and for cryopreserved blood/IL-1β was established in 50.000 ng/mL of LTA, or 5,41 UEE/mL. The LAL test presented a false-positive result from 10.000 ng/mL of ALT. The results presented in this study provide important information on the comparison between the rabbit pyrogen test, MAT and LAL, contributing with data to the evaluation of MAT, involving pyrogens other than endotoxin, and also to the acceptance of this test by the regulatory organs in Brazil aiming at a possible animal substitution, and guaranteeing, then, the health security of the population.

Page generated in 0.0563 seconds