Spelling suggestions: "subject:"thermoelectric cooling"" "subject:"thermoelectric fooling""
1 |
Optimization of thermoelectric cooling by the use of cascadesCowling, Peter Warning 08 1900 (has links)
No description available.
|
2 |
Optimization of a paraffin cooling system for an automated tissue embedding centerLandis, Adam. January 2004 (has links)
Thesis (M.S.)--Ohio University, March, 2004. / Title from PDF t.p. Includes bibliographical references (leaves 129-131).
|
3 |
Distributed control to improve performance of thermoelectric coolersHarvey, Richard D. January 2005 (has links)
Thesis (M.S. in Mechanical Engineering)--Vanderbilt University, Aug. 2005. / Title from title screen. Includes bibliographical references.
|
4 |
Enhancement of thermionic cooling using Monte Carlo simulationStephen, Alexander January 2014 (has links)
Advances in the field of semiconductor physics have allowed for rapid development of new, more powerful devices. The new fabrication techniques allow for reductions in device geometry, increasing the possible wafer packing density. The increased output power comes with the price of excessive heat generation, the removal of which proves problematic at such scales for conventional cooling systems. Consequently, there is a rising demand for new cooling systems, preferably those that do not add large amount of additional bulk to the system. One promising system is the thermoelectric (TE) cooler which is small enough to be integrated onto the device wafer. Unlike more traditional gas and liquid coolers, TE coolers do not require moving parts or external liquid reservoirs, relying only on the flow of electrons to transport heat energy away from the device. Although TE cooling provides a neat solution for the extraction of heat from micron scale devices, it can normally only produce small amounts of cooling of 1-2 Kelvin, limiting its application to low power devices. This research aimed to find ways to enhance the performance of the TE cooler using detailed simulation analysis. For this, a self consistent, semi-classical, ensemble Monte Carlo model was designed to investigate the operation of the TE cooler at a higher level than would be possible with experimental measurements alone. As part of its development, the model was validated on a variety of devices including a Gunn diode and two micro-cooler designs from the literature, one which had been previously simulated and another which had been experimentally analysed. When applied to the TE cooler of focus, novel operational data was obtained and signification improvements in cooling power were found with only minor alterations to the device structure and without need for an increase in volume.
|
5 |
Investigations into thermionic cooling for domestic refrigerationLough, Benjamin C. C. January 2004 (has links)
Thesis (Ph.D.)--University of Wollongong, 2004. / Typescript. Includes bibliographical references: leaf 156-164.
|
6 |
Experimental study of thermosiphon performanceSivanagere, Sumeeth S. January 2002 (has links)
Thesis (M.S.)--West Virginia University, 2002. / Title from document title page. Document formatted into pages; contains vii, 66 p. : ill. (some col.). Vita. Includes abstract. Includes bibliographical references (p. 29).
|
7 |
Comprehensive optimization for thermoelectric refrigeration devicesTaylor, Robert A., January 2005 (has links)
Thesis (M.S.)--University of Missouri-Columbia, 2005. / The entire dissertation/thesis text is included in the research.pdf file; the official abstract appears in the short.pdf file (which also appears in the research.pdf); a non-technical general description, or public abstract, appears in the public.pdf file. Title from title screen of research.pdf file viewed on (December 20, 2006) Includes bibliographical references.
|
8 |
Desenvolvimento de um sistema de condicionamento de ar em escala reduzida utilizando módulos termoelétricosMaestrelli, Everlise January 2015 (has links)
Este trabalho apresenta o desenvolvimento do protótipo em escala reduzida de um sistema de refrigeração de ambientes baseado no efeito Peltier, para aplicação análoga aos condicionadores de ar comercializados atualmente, utilizando módulos termoelétricos. A pesquisa é motivada pela possibilidade de concepção de um equipamento de refrigeração para obtenção de conforto térmico, sem algumas desvantagens dos condicionadores de ar comerciais como por exemplo a vibração, ruído além das grandes dimensões como na atualidade pode ser visto. Através da pesquisa exploratório busca-se detalhar o fenômeno térmico conhecido como efeito Peltier, suas características, materiais além da revisão do estado da arte afim de encontrar estudos correlatos a proposta apresentada. Apresentam-se as etapas e detalha-se o desenvolvimento do protótipo compreendendo a parte mecânica, elétrica e térmica. Em um segundo momento, o protótipo desenvolvido é submetido a testes de validação que demonstram a real funcionalidade conforme previsto, porém, com baixo rendimento em comparação aos equipamentos existentes de refrigeração. Realiza-se ainda, uma análise comparativa por extrapolação entre o protótipo desenvolvido e condicionadores de ar comercializados permitindo a avaliação de possibilidade e implementação em escala real de aplicação. Conclui-se sugerindo melhorias e novos estudos para otimização e ajustes nas dinâmicas térmicas podem obter um produto tecnicamente viável e comercialmente apropriado. / This work describes the development of a prototype for a cooling system for environments with base on the Peltier effect, for application analogous to air conditioners currently marketed, using thermoelectric modules. The search is motivated by the possibility of conception of a cooling device to obtain a thermal comfort without some disadvantages of commercial air conditioners such as vibration, noise beyond large as can be seen today. Through exploratory research seeks to detail the thermal phenomenon known as the Peltier effect, their characteristics, materials beyond the state of the art review in order to find related studies the proposal. Presents the steps and prototype development details related the mechanics part, electrical and thermal. In a second moment, the prototype is submitted to validation tests that demonstrate the functioning as planned however, with low performance compared with commercial refrigeration equipment. It presents also a comparative analysis through extrapolation between the prototype and air conditioners commercialized allowing the evaluation of possibility and implementation in full-scale application. It concluded that the proposed improvements and new studies for optimization and adjustments in the thermal dynamics can obtain a product technically viable and commercially appropriate.
|
9 |
Desenvolvimento de um sistema de condicionamento de ar em escala reduzida utilizando módulos termoelétricosMaestrelli, Everlise January 2015 (has links)
Este trabalho apresenta o desenvolvimento do protótipo em escala reduzida de um sistema de refrigeração de ambientes baseado no efeito Peltier, para aplicação análoga aos condicionadores de ar comercializados atualmente, utilizando módulos termoelétricos. A pesquisa é motivada pela possibilidade de concepção de um equipamento de refrigeração para obtenção de conforto térmico, sem algumas desvantagens dos condicionadores de ar comerciais como por exemplo a vibração, ruído além das grandes dimensões como na atualidade pode ser visto. Através da pesquisa exploratório busca-se detalhar o fenômeno térmico conhecido como efeito Peltier, suas características, materiais além da revisão do estado da arte afim de encontrar estudos correlatos a proposta apresentada. Apresentam-se as etapas e detalha-se o desenvolvimento do protótipo compreendendo a parte mecânica, elétrica e térmica. Em um segundo momento, o protótipo desenvolvido é submetido a testes de validação que demonstram a real funcionalidade conforme previsto, porém, com baixo rendimento em comparação aos equipamentos existentes de refrigeração. Realiza-se ainda, uma análise comparativa por extrapolação entre o protótipo desenvolvido e condicionadores de ar comercializados permitindo a avaliação de possibilidade e implementação em escala real de aplicação. Conclui-se sugerindo melhorias e novos estudos para otimização e ajustes nas dinâmicas térmicas podem obter um produto tecnicamente viável e comercialmente apropriado. / This work describes the development of a prototype for a cooling system for environments with base on the Peltier effect, for application analogous to air conditioners currently marketed, using thermoelectric modules. The search is motivated by the possibility of conception of a cooling device to obtain a thermal comfort without some disadvantages of commercial air conditioners such as vibration, noise beyond large as can be seen today. Through exploratory research seeks to detail the thermal phenomenon known as the Peltier effect, their characteristics, materials beyond the state of the art review in order to find related studies the proposal. Presents the steps and prototype development details related the mechanics part, electrical and thermal. In a second moment, the prototype is submitted to validation tests that demonstrate the functioning as planned however, with low performance compared with commercial refrigeration equipment. It presents also a comparative analysis through extrapolation between the prototype and air conditioners commercialized allowing the evaluation of possibility and implementation in full-scale application. It concluded that the proposed improvements and new studies for optimization and adjustments in the thermal dynamics can obtain a product technically viable and commercially appropriate.
|
10 |
Desenvolvimento de um sistema de condicionamento de ar em escala reduzida utilizando módulos termoelétricosMaestrelli, Everlise January 2015 (has links)
Este trabalho apresenta o desenvolvimento do protótipo em escala reduzida de um sistema de refrigeração de ambientes baseado no efeito Peltier, para aplicação análoga aos condicionadores de ar comercializados atualmente, utilizando módulos termoelétricos. A pesquisa é motivada pela possibilidade de concepção de um equipamento de refrigeração para obtenção de conforto térmico, sem algumas desvantagens dos condicionadores de ar comerciais como por exemplo a vibração, ruído além das grandes dimensões como na atualidade pode ser visto. Através da pesquisa exploratório busca-se detalhar o fenômeno térmico conhecido como efeito Peltier, suas características, materiais além da revisão do estado da arte afim de encontrar estudos correlatos a proposta apresentada. Apresentam-se as etapas e detalha-se o desenvolvimento do protótipo compreendendo a parte mecânica, elétrica e térmica. Em um segundo momento, o protótipo desenvolvido é submetido a testes de validação que demonstram a real funcionalidade conforme previsto, porém, com baixo rendimento em comparação aos equipamentos existentes de refrigeração. Realiza-se ainda, uma análise comparativa por extrapolação entre o protótipo desenvolvido e condicionadores de ar comercializados permitindo a avaliação de possibilidade e implementação em escala real de aplicação. Conclui-se sugerindo melhorias e novos estudos para otimização e ajustes nas dinâmicas térmicas podem obter um produto tecnicamente viável e comercialmente apropriado. / This work describes the development of a prototype for a cooling system for environments with base on the Peltier effect, for application analogous to air conditioners currently marketed, using thermoelectric modules. The search is motivated by the possibility of conception of a cooling device to obtain a thermal comfort without some disadvantages of commercial air conditioners such as vibration, noise beyond large as can be seen today. Through exploratory research seeks to detail the thermal phenomenon known as the Peltier effect, their characteristics, materials beyond the state of the art review in order to find related studies the proposal. Presents the steps and prototype development details related the mechanics part, electrical and thermal. In a second moment, the prototype is submitted to validation tests that demonstrate the functioning as planned however, with low performance compared with commercial refrigeration equipment. It presents also a comparative analysis through extrapolation between the prototype and air conditioners commercialized allowing the evaluation of possibility and implementation in full-scale application. It concluded that the proposed improvements and new studies for optimization and adjustments in the thermal dynamics can obtain a product technically viable and commercially appropriate.
|
Page generated in 0.079 seconds