• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 61
  • 61
  • 35
  • 20
  • 20
  • 17
  • 12
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

TIME HISTORY ANALYSIS OF THE DYNAMIC RESPONSE OF HORIZONTAL LIFELINES

YU, XIAOHUA ANNIE 02 September 2003 (has links)
No description available.
22

Selection and Scaling of Seismic Excitations for Time-History Analysis of Reinforced Concrete Frame Buildings

Galin, Sanja 01 February 2012 (has links)
Time history-analyses of building structures have been used for a quite long time for research at universities. Considering the advantage of time-history analysis relative to the equivalent static force method, the National Building of Canada and other modern building codes around the world require the use of time-history analysis in the design of specified types of buildings located in seismic regions. One of the main issues in the use of time-history analysis is related to the selection and scaling of the seismic excitations (i.e., accelerograms) to be compatible with the design spectrum for the location considered. Currently, both recorded (i.e., “real”) accelerograms and artificial accelerograms are used in the analyses. The objective of this study is to determine the effects of the selection and scaling of seismic excitations on the response of reinforced concrete frame buildings. Three reinforced concrete frame buildings with heights of 4 storey, 10 storey and 16 storey, designed for Vancouver (high seismic zone) were used in this study. Five sets of seismic excitations were used in the analysis – one set of “real” accelerograms, and four sets of artificial accelerograms obtained by different methods. All sets were scaled to be compatible with the design spectrum for Vancouver. Both linear and nonlinear time history analyses were conducted on the buildings considered. Interstorey drifts and storey shear forces were used as response parameters. The results from the linear analysis show that both the interstorey drifts and the shear forces are affected significantly by the type of the excitation set. Similarly, the effects of the type of the seismic excitations on the drifts from nonlinear analysis are substantial. On the other hand, the influence of the excitation sets on the storey shears from nonlinear analysis are quite small. Based on the results from this study, sets of scaled real records are preferred for use in time-history analysis of building structures. If such records are not available, then sets of simulated accelerograms based on the regional seismic characteristics should be used.
23

Upgrade of Seismically Deficient Steel Frame Structures Built in Canada Between the 1960s and 1980s Using Passive Supplemental Damping

Kyriakopoulos, Nikolas 20 November 2012 (has links)
A typical 1960s Type 2 Construction steel MRF hospital structure in Quebec, representative of a prevalent construction philosophy of the time, was investigated and modelled in OpenSees using an advanced strength degradation model. The structure was then subjected to a nonlinear time-history analysis (NLTHA) for Montreal (MTL) and Vancouver (VAN) ground motions and was found to be deficient under the design hazard levels. Retrofits were proposed for the two orthogonal frames at both sites using a performance-based approach. An experimental program determined that the connections had less ductility than expected and began deteriorating around 2.0% interstorey drift. The OpenSees model was updated according to the experimental connection behaviour and the predicted NLTHA performance of the structure worsened. The proposed retrofit designs for both orthogonal frames in both MTL and VAN were updated with the new connection behaviour and final retrofit designs were proposed.
24

Upgrade of Seismically Deficient Steel Frame Structures Built in Canada Between the 1960s and 1980s Using Passive Supplemental Damping

Kyriakopoulos, Nikolas 20 November 2012 (has links)
A typical 1960s Type 2 Construction steel MRF hospital structure in Quebec, representative of a prevalent construction philosophy of the time, was investigated and modelled in OpenSees using an advanced strength degradation model. The structure was then subjected to a nonlinear time-history analysis (NLTHA) for Montreal (MTL) and Vancouver (VAN) ground motions and was found to be deficient under the design hazard levels. Retrofits were proposed for the two orthogonal frames at both sites using a performance-based approach. An experimental program determined that the connections had less ductility than expected and began deteriorating around 2.0% interstorey drift. The OpenSees model was updated according to the experimental connection behaviour and the predicted NLTHA performance of the structure worsened. The proposed retrofit designs for both orthogonal frames in both MTL and VAN were updated with the new connection behaviour and final retrofit designs were proposed.
25

Influence Of The Shear Wall Area To Floor Area Ratio On The Seismic Performance Of Existing Reinforced Concrete Buildings

Gunel, Orhun Ahmet 01 January 2013 (has links) (PDF)
An analytical study is performed to evaluate the influence of shear wall area to floor area ratio on the behavior of existing mid-rise reinforced concrete buildings under earthquake loading. The seismic performance of five existing school buildings with shear wall ratios between 0.00% and 2.50% in both longitudinal and transverse directions and their strengthened counterparts are evaluated. Based on the structural properties of the existing buildings, additional buildings with varying shear wall ratios are designed. Consequently, twenty four buildings with different floor plans, number of stories, cross-sectional properties of the members and material strengths are acquired. Nonlinear time-history analyses are performed for all buildings by utilizing the software program, SAP2000 v14.2.0. under seven different ground motion records. The results indicated that roof drifts and plastic deformations reduce with increasing shear wall ratios, but the rate of decrease is lower for higher shear wall ratios. Buildings with 1.00% shear wall ratio have significantly lower roof drifts and plastic deformations when compared to buildings with 0.00% or 0.50% shear wall ratio. Roof drifts and plastic deformations are minimized when the shear wall ratio is increased to 1.50%. After this limit, addition of shear walls has only a slight effect on the seismic performance of the analyzed buildings.
26

Selection and Scaling of Seismic Excitations for Time-History Analysis of Reinforced Concrete Frame Buildings

Galin, Sanja 01 February 2012 (has links)
Time history-analyses of building structures have been used for a quite long time for research at universities. Considering the advantage of time-history analysis relative to the equivalent static force method, the National Building of Canada and other modern building codes around the world require the use of time-history analysis in the design of specified types of buildings located in seismic regions. One of the main issues in the use of time-history analysis is related to the selection and scaling of the seismic excitations (i.e., accelerograms) to be compatible with the design spectrum for the location considered. Currently, both recorded (i.e., “real”) accelerograms and artificial accelerograms are used in the analyses. The objective of this study is to determine the effects of the selection and scaling of seismic excitations on the response of reinforced concrete frame buildings. Three reinforced concrete frame buildings with heights of 4 storey, 10 storey and 16 storey, designed for Vancouver (high seismic zone) were used in this study. Five sets of seismic excitations were used in the analysis – one set of “real” accelerograms, and four sets of artificial accelerograms obtained by different methods. All sets were scaled to be compatible with the design spectrum for Vancouver. Both linear and nonlinear time history analyses were conducted on the buildings considered. Interstorey drifts and storey shear forces were used as response parameters. The results from the linear analysis show that both the interstorey drifts and the shear forces are affected significantly by the type of the excitation set. Similarly, the effects of the type of the seismic excitations on the drifts from nonlinear analysis are substantial. On the other hand, the influence of the excitation sets on the storey shears from nonlinear analysis are quite small. Based on the results from this study, sets of scaled real records are preferred for use in time-history analysis of building structures. If such records are not available, then sets of simulated accelerograms based on the regional seismic characteristics should be used.
27

Effect Of Shear Walls On The Behavior Of Reinforced Concrete Buildings Under Earthquake Loading

Comlekoglu, Hakki Gurhan 01 December 2009 (has links) (PDF)
An analytical study was performed to evaluate the effect of shear wall ratio on the dynamic behavior of mid-rise reinforced concrete structures. The primary aim of this study is to examine the influence of shear wall area to floor area ratio on the dynamic performance of a building. Besides, the effect of shear wall configuration and area of existing columns on the seismic performance of the buildings were also investigated. For this purpose, twenty four mid-rise building models that have five and eight stories and shear wall ratios ranging between 0.51 and 2.17 percent in both directions were generated. These building models were examined by carrying out nonlinear time-history analyses using PERFORM 3D. The analytical model used in this study was verified by comparing the analytical results with the experimental results of a full-scale seven-story reinforced concrete shear wall building that was tested for U.S.-Japan Cooperative Research Program in 1981. In the analyses, seven different ground motion time histories were used and obtained data was averaged and utilized in the evaluation of the seismic performance. Main parameters affecting the overall performance were taken as roof and interstory drifts, their distribution throughout the structure and the base shear characteristics. The analytical results indicated that at least 1.0 percent shear wall ratio should be provided in the design of mid-rise buildings, in order to control observed drift. In addition / when the shear wall ratio increased beyond 1.5 percent, it was observed that the improvement of the seismic performance is not as significant.
28

Vertical Ground Motion Influence On Seismically Isolated &amp / Unisolated Bridges

Reyhanogullari, Naim Eser 01 April 2010 (has links) (PDF)
In this study influences of vertical ground motion on seismically isolated bridges were investigated for seven different earthquake data. One assessment of bearing effect involves the calculation of vertical earthquake load on the seismically isolated bridges. This paper investigates the influence of vertical earthquake excitation on the response of briefly steel girder composite bridges (SCB) with and without seismic isolation through specifically selected earthquakes. In detail, the bridge is composed of 30m long three spans, concrete double piers at each axis supported by mat foundations with pile systems. At both end of the spans there exists concrete abutments to support superstructure of the bridge. SCBs which were seismically isolated with nine commonly preferred different lead&amp / #8208 / rubber bearings (LRB) under each steel girder were analyzed. Then, the comparisons were made with a SCB without seismic isolation. Initially, a preliminary design was made and reasonable sections for the bridge have been obtained. As a result of this, the steel girder bridge sections were checked with AASHTO provisions and analytical model was updated accordingly. Earthquake records were thought as the main loading sources. Hence both cases were exposed to tri&amp / #8208 / axial earthquake loads in order to understand the effects under such circumstances. Seven near fault earthquake data were selected by considering possession of directivity. Several runs using the chosen earthquakes were performed in order to be able to derive satisfactory comparisons between different types of isolators. Analytical calculations were conducted using well known structural analysis software (SAS) SAP2000. Nonlinear time history analysis was performed using the analytical model of the bridge with and without seismic isolation. Response data collected from SAS was used to determine the vertical load on the piers and middle span midspan moment on the steel girders due to the vertical and horizontal component of excitation. Comparisons dealing with the effects of horizontal only and horizontal plus vertical earthquake loads were introduced.
29

Selection and Scaling of Seismic Excitations for Time-History Analysis of Reinforced Concrete Frame Buildings

Galin, Sanja 01 February 2012 (has links)
Time history-analyses of building structures have been used for a quite long time for research at universities. Considering the advantage of time-history analysis relative to the equivalent static force method, the National Building of Canada and other modern building codes around the world require the use of time-history analysis in the design of specified types of buildings located in seismic regions. One of the main issues in the use of time-history analysis is related to the selection and scaling of the seismic excitations (i.e., accelerograms) to be compatible with the design spectrum for the location considered. Currently, both recorded (i.e., “real”) accelerograms and artificial accelerograms are used in the analyses. The objective of this study is to determine the effects of the selection and scaling of seismic excitations on the response of reinforced concrete frame buildings. Three reinforced concrete frame buildings with heights of 4 storey, 10 storey and 16 storey, designed for Vancouver (high seismic zone) were used in this study. Five sets of seismic excitations were used in the analysis – one set of “real” accelerograms, and four sets of artificial accelerograms obtained by different methods. All sets were scaled to be compatible with the design spectrum for Vancouver. Both linear and nonlinear time history analyses were conducted on the buildings considered. Interstorey drifts and storey shear forces were used as response parameters. The results from the linear analysis show that both the interstorey drifts and the shear forces are affected significantly by the type of the excitation set. Similarly, the effects of the type of the seismic excitations on the drifts from nonlinear analysis are substantial. On the other hand, the influence of the excitation sets on the storey shears from nonlinear analysis are quite small. Based on the results from this study, sets of scaled real records are preferred for use in time-history analysis of building structures. If such records are not available, then sets of simulated accelerograms based on the regional seismic characteristics should be used.
30

Effect of Multi-support Excitation on the Seismic Behavior of Single-pylon Cable-stayed Bridges

Subedi, Arjun 01 December 2014 (has links)
Cable-stayed bridges are popular these days in spite of their complexity in shape and design. Cable-stayed bridges are ideal for a navigational channel due to their high clearance and long central span. These types of bridges also possess advantages over suspension bridges, especially when local site conditions are not suitable for anchoring the towers. In most of the cases, cable-stayed bridges are self-supportive or require less anchorage. Although symmetrical cable-stayed bridges are dominant, asymmetrical bridges are also common as well due to ground layouts and other restrictions like economy, aesthetic purpose. Added counter weight and eccentricity of asymmetrical bridge may highly affect the response of the structure under earthquake loading. For the same length span bridge, the response of the asymmetric one may have an amplified response compared to the symmetric one with the same span length and also, may not follow any predictable trend. This study presents a multi-support analysis for four models, which are, 200 m symmetrical, 400 m symmetrical, 200 m asymmetrical and 400 m asymmetrical bridges. Ground motions has been recorded by using accelerometers. The recorded ground motion depends on the direction of the accelerometer. To remove this dependency, the principal components of each ground motion were found and used for the analysis and the models were excited in the transverse direction. The models were run under both multi-support excitation and identical-support excitation for displacement time-history analysis using SAP2000. Ratio of stresses and deflections were compared for the bridges with the same span length. According to this study, on 200 m asymmetrical bridge, multi-support excitation factored responses up to 4%, while on 400 m asymmetrical bridge, responses are factored up to 20% compared to the identical-support excitation. It is noted that responses of asymmetrical bridges are factored up making identical-support excitation non-conservative.

Page generated in 0.0748 seconds