• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Ultrassonografia transcraniana combinada a teste de olfação comparados à imagem molecular com TRODAT para diagnóstico da doença de Parkinson / Combined assessment by transcranial sonography and Sniffin\' Sticks test compared to brain TRODAT SPECT for Parkinson\'s disease diagnosis

Almeida, Kelson James Silva de 28 November 2016 (has links)
INTRODUÇÃO: O diagnóstico da doença de Parkinson (DP) pode ser um desafio, principalmente nas fases precoces da doença. O diagnóstico acurado desta condição requer mais que a avaliação clínica isolada. A Tomografia computadorizada do crânio de fóton único (SPECT) e a ultrassonografia transcraniana (USTC) podem ser úteis na diferenciação entre a DP e as síndromes parkinsonianas atípicas ou entre a DP e o tremor essencial. O presente estudo objetivou investigar a acurácia da USTC combinada com o teste de olfação Sniffin\' Sticks (SST-16) para diferenciar pacientes com DP de controles saudáveis e comparar com a acurácia do SPECT com 99mTc- TRODAT-1 (TRODAT). MÉTODOS: Trata-se de um estudo transversal que incluiu pacientes com DP segundo critérios do United Kingdom Parkinson\'s disease Society e um grupo controle de indivíduos saudáveis pareados para idade e gênero. Os pacientes foram examinados por um especialista em distúrbios do movimento e submetidos a SPECT encefálico com TRODAT, USTC e SST-16. Curvas Receiver Operating Characteristic (ROC) foram obtidas para definir os pontos de corte dos métodos avaliados para detecção de DP. RESULTADOS: Vinte indivíduos com DP (13 homens e 7 mulheres) e 9 participantes saudáveis foram admitidos no estudo. A idade mediana de início dos sintomas foi de 56,5 anos e a mediana do tempo de duração da doença foi de 5 anos. Maior área de ecogênica da substância negra (SN) foi observada no grupo com DP (p=0,013). Área ecogênica da SN de 0,22 cm2 foi definida pela curva ROC para detecção de DP, com acurácia de 79%. O ponto de corte do potencial de ligação do TRODAT no striatum foi 0,90, com acurácia de 99% para o diagnóstico de DP. Escore do SST-16 maior ou igual a 10 pontos foi o ponto de corte para detecção de DP, com acurácia de 85,8%. A combinação da USTC com teste da olfação levou à acurácia de 95% para detecção de DP. CONCLUSÃO: A combinação da USTC com SST-16 eleva a capacidade de ! detecção da DP. A acurácia da USTC combinada ao SST-16 para identificar pacientes com DP idiopática aproximou-se da acurácia do SPECT com TRODAT / INTRODUCTION: Diagnosing Parkinson\'s disease (PD) can be challenging, especially in the early stages of the disease. An accurate diagnosis requires more than clinical findings alone. Brain single-photon emission computed tomography (SPECT) and transcranial sonography (TCS) are helpful for diagnosing PD and differentiating it from atypical parkinsonian syndromes as well as essential tremor. This study aimed to investigate the accuracy of TCS combined with the Sniffin\' sticks olfactory test (SST-16) for differentiation between idiopathic PD patients and healthy controls compared to that of 99mTc-TRODAT-1 SPECT (TRODAT). METHODS: A cross-sectional study included PD patients diagnosed in accordance with United Kingdom PD Society Brain Bank criteria and a control group of age and sex-matched healthy subjects. All patients were examined by a movement disorder specialist and underwent brain SPECT using TRODAT, TCS examination and SST-16 test. Receiver Operating Characteristic (ROC) curves were used to calculate cut-off points for TCS, Striatal TRODAT binding potentials and SST-16. The area under the ROC curve determined the accuracy of the method. RESULTS: Twenty patients with PD (13 males and 7 females) and nine healthy subjects were included. Median age of PD onset was 56.5 years with median disease duration of 5 years. A larger substantia nigra (SN) echogenic area was observed in the PD group (p=0.013). SN echogenic area cut-off point of 0.22 cm2 was obtained from a ROC curve for PD diagnosis. Considering this cut-off point, TCS accuracy was estimated at 79.2% for PD diagnosis. The cut-off value of 0.90 for striatal TRODAT binding was associated with 99% accuracy for the diagnosis of PD. SST-16 values equal or greater than 10 points showed a 85.8% accuracy for PD diagnosis. Combination of both SST-16 and TCS improved the accuracy to 95% for PD diagnosis. CONCLUSION: Combined assessment of SST-16 and TCS are reliable and highly accurate for distinguishing PD patients from healthy controls. The accuracy of TCS combined with SST-16 for differentiation between idiopathic PD patients and healthy controls is similar to that of SPECT TRODAT
2

Estudo das lesões hiperdensas em tomografias computadorizadas de crânio de pacientes submetidos a tratamento endovascular para o acidente vascular cerebral isquêmico agudo / Study of hyperdense lesions on computed tomography scan on the head of patients undergoing endovascular treatment for acute ischemic stroke

Cabral, Fernando Bermudes 02 June 2015 (has links)
INTRODUÇÃO: As imagens de lesões hiperdensas encontradas em exames de tomografia (TC) de crânio após o tratamento endovascular do acidente vascular cerebral isquêmico (AVCi) agudo têm sido correlacionadas ao risco de transformação hemorrágica após o AVC. Entretanto, a correlação entre as lesões hiperdensas e a área cerebral infartada é desconhecida. O objetivo deste estudo é determinar a correlação entre as lesões hiperdensas encontradas em TC de crânio realizadas logo após tratamento endovascular do AVCi agudo e a área de AVC isquêmico. MATERIAIS E MÉTODOS: Foram coletados retrospectivamente dados radiológicos de pacientes com AVCi agudo por oclusão de grandes vasos da circulação anterior submetidos ao tratamento endovascular. Foram analisadas imagens de TC de crânio nas primeiras 24 horas e até 21 dias após o tratamento. As áreas hiperdensas foram classificadas utilizando o escore ASPECTS e comparadas com as áreas de AVC isquêmico final pelo mesmo escore. As imagens foram analisadas independentemente por dois avaliadores, sendo que um terceiro avaliador analisou os casos discordantes. A concordância entre avaliadores (CCI) e os valores de sensibilidade, especificidade, preditivos positivo e negativos e acurácia foram calculados. RESULTADOS: Lesões hiperdensas foram encontradas em 71 dos 93 (76,34%) pacientes com AVC isquêmico de circulação anterior. As áreas captantes de contraste corresponderam às áreas de AVC final segundo o escore ASPECTS (CCI=0,58 [0,40 0,71]). Os valores para cada região individual foram avaliados e a sensibilidade variou de 58,3% a 96,9%, a especificidade de 42,9% a 95,6%, os valores preditivos positivos de 71,4% a 97,7%, os valores preditivos negativos de 53,8% a 79,5% e os valores de acurácia de 0,68 a 0,91. Os maiores valores de sensibilidade foram encontrados para os núcleos lentiforme (96,9%) e caudado (80,4%) e para a cápsula interna (87,5%) e os menores para os córtices M1 (58,3%) e M6 (66,7%). CONCLUSÕES: A aplicação do escore ASPECTS para avaliação das imagens de tomografia de crânio após o tratamento endovascular do AVCi agudo que apresentam captação de contraste, demonstrou ser uma ferramenta útil para a predição da área final de infarto cerebral. A predição foi maior na região profunda e menor nos córtices cerebrais, provavelmente devido maior circulação colateral cortical. Além disso, o método se mostrou reprodutível e de fácil utilização. / INTRODUCTION: The hyperdense lesions images found in head computed tomography (CT) scan after endovascular treatment have been correlated to risk of hemorrhagic transformation after stroke. However, the correlation between hyperdense lesions and the infarcted brain area is unknown. The aim of this study is to determine the correlation between the hyperdense lesions found on CT scan performed after endovacular treatment of acute stroke and final ischemic stroke area. MATERIALS AND METHODS: It was collected radiological data of patients with acute ischemic stroke by occlusion of large vessels in the anterior circulation were treated with endovascular treatment. Head CT scan were evaluated in the first 24 hours and by 21 days after treatment. The hyperdense areas were rated using the ASPECTS score and compared with final ischemic stroke by the same score. The images were analyzed independently by two reviewers, and a third evaluator examined the discordant cases. The interrater agreement (ICC) and the sensitivity, specificity, positive and negative predictive values and accuracy were calculated. RESULTS: hyperdense lesions were found in 71 of 93 (76.34%) patients with ischemic stroke of anterior circulation. The contrast iodineaccumulating areas corresponded to the final stroke areas (ICC = 0.58 [0.40 to 0.71]) as the ASPECTS score. The values for each individual region were evaluated and the sensitivity ranged from 58.3% to 96.9%, specificity of 42.9% to 95.6%, the positive predictive value of 71.4% to 97, 7%, the negative predictive value of 53.8% to 79.5% and the accuracy of values from 0.68 to 0.91. The higher sensitivity found for lenticular nuclei (96.9%) and caudate (80.4%) and the internal capsule (87.5%) and lower for M1 (58.3%) and M6 (66.7%) cortices. CONCLUSIONS: The use of the ASPECTS score for evaluation of CT head scan after endovascular treatment of acute ischemic stroke images that exhibit contrast enhancement proved to be a useful tool for predicting the final ischemic stroke area. The prediction was higher in the deep region and lower in the cerebral cortex, probably because the cortical collateral circulation. Futhermore, these method was reproducible and easy to use.
3

Estudo das lesões hiperdensas em tomografias computadorizadas de crânio de pacientes submetidos a tratamento endovascular para o acidente vascular cerebral isquêmico agudo / Study of hyperdense lesions on computed tomography scan on the head of patients undergoing endovascular treatment for acute ischemic stroke

Fernando Bermudes Cabral 02 June 2015 (has links)
INTRODUÇÃO: As imagens de lesões hiperdensas encontradas em exames de tomografia (TC) de crânio após o tratamento endovascular do acidente vascular cerebral isquêmico (AVCi) agudo têm sido correlacionadas ao risco de transformação hemorrágica após o AVC. Entretanto, a correlação entre as lesões hiperdensas e a área cerebral infartada é desconhecida. O objetivo deste estudo é determinar a correlação entre as lesões hiperdensas encontradas em TC de crânio realizadas logo após tratamento endovascular do AVCi agudo e a área de AVC isquêmico. MATERIAIS E MÉTODOS: Foram coletados retrospectivamente dados radiológicos de pacientes com AVCi agudo por oclusão de grandes vasos da circulação anterior submetidos ao tratamento endovascular. Foram analisadas imagens de TC de crânio nas primeiras 24 horas e até 21 dias após o tratamento. As áreas hiperdensas foram classificadas utilizando o escore ASPECTS e comparadas com as áreas de AVC isquêmico final pelo mesmo escore. As imagens foram analisadas independentemente por dois avaliadores, sendo que um terceiro avaliador analisou os casos discordantes. A concordância entre avaliadores (CCI) e os valores de sensibilidade, especificidade, preditivos positivo e negativos e acurácia foram calculados. RESULTADOS: Lesões hiperdensas foram encontradas em 71 dos 93 (76,34%) pacientes com AVC isquêmico de circulação anterior. As áreas captantes de contraste corresponderam às áreas de AVC final segundo o escore ASPECTS (CCI=0,58 [0,40 0,71]). Os valores para cada região individual foram avaliados e a sensibilidade variou de 58,3% a 96,9%, a especificidade de 42,9% a 95,6%, os valores preditivos positivos de 71,4% a 97,7%, os valores preditivos negativos de 53,8% a 79,5% e os valores de acurácia de 0,68 a 0,91. Os maiores valores de sensibilidade foram encontrados para os núcleos lentiforme (96,9%) e caudado (80,4%) e para a cápsula interna (87,5%) e os menores para os córtices M1 (58,3%) e M6 (66,7%). CONCLUSÕES: A aplicação do escore ASPECTS para avaliação das imagens de tomografia de crânio após o tratamento endovascular do AVCi agudo que apresentam captação de contraste, demonstrou ser uma ferramenta útil para a predição da área final de infarto cerebral. A predição foi maior na região profunda e menor nos córtices cerebrais, provavelmente devido maior circulação colateral cortical. Além disso, o método se mostrou reprodutível e de fácil utilização. / INTRODUCTION: The hyperdense lesions images found in head computed tomography (CT) scan after endovascular treatment have been correlated to risk of hemorrhagic transformation after stroke. However, the correlation between hyperdense lesions and the infarcted brain area is unknown. The aim of this study is to determine the correlation between the hyperdense lesions found on CT scan performed after endovacular treatment of acute stroke and final ischemic stroke area. MATERIALS AND METHODS: It was collected radiological data of patients with acute ischemic stroke by occlusion of large vessels in the anterior circulation were treated with endovascular treatment. Head CT scan were evaluated in the first 24 hours and by 21 days after treatment. The hyperdense areas were rated using the ASPECTS score and compared with final ischemic stroke by the same score. The images were analyzed independently by two reviewers, and a third evaluator examined the discordant cases. The interrater agreement (ICC) and the sensitivity, specificity, positive and negative predictive values and accuracy were calculated. RESULTS: hyperdense lesions were found in 71 of 93 (76.34%) patients with ischemic stroke of anterior circulation. The contrast iodineaccumulating areas corresponded to the final stroke areas (ICC = 0.58 [0.40 to 0.71]) as the ASPECTS score. The values for each individual region were evaluated and the sensitivity ranged from 58.3% to 96.9%, specificity of 42.9% to 95.6%, the positive predictive value of 71.4% to 97, 7%, the negative predictive value of 53.8% to 79.5% and the accuracy of values from 0.68 to 0.91. The higher sensitivity found for lenticular nuclei (96.9%) and caudate (80.4%) and the internal capsule (87.5%) and lower for M1 (58.3%) and M6 (66.7%) cortices. CONCLUSIONS: The use of the ASPECTS score for evaluation of CT head scan after endovascular treatment of acute ischemic stroke images that exhibit contrast enhancement proved to be a useful tool for predicting the final ischemic stroke area. The prediction was higher in the deep region and lower in the cerebral cortex, probably because the cortical collateral circulation. Futhermore, these method was reproducible and easy to use.
4

Ultrassonografia transcraniana combinada a teste de olfação comparados à imagem molecular com TRODAT para diagnóstico da doença de Parkinson / Combined assessment by transcranial sonography and Sniffin\' Sticks test compared to brain TRODAT SPECT for Parkinson\'s disease diagnosis

Kelson James Silva de Almeida 28 November 2016 (has links)
INTRODUÇÃO: O diagnóstico da doença de Parkinson (DP) pode ser um desafio, principalmente nas fases precoces da doença. O diagnóstico acurado desta condição requer mais que a avaliação clínica isolada. A Tomografia computadorizada do crânio de fóton único (SPECT) e a ultrassonografia transcraniana (USTC) podem ser úteis na diferenciação entre a DP e as síndromes parkinsonianas atípicas ou entre a DP e o tremor essencial. O presente estudo objetivou investigar a acurácia da USTC combinada com o teste de olfação Sniffin\' Sticks (SST-16) para diferenciar pacientes com DP de controles saudáveis e comparar com a acurácia do SPECT com 99mTc- TRODAT-1 (TRODAT). MÉTODOS: Trata-se de um estudo transversal que incluiu pacientes com DP segundo critérios do United Kingdom Parkinson\'s disease Society e um grupo controle de indivíduos saudáveis pareados para idade e gênero. Os pacientes foram examinados por um especialista em distúrbios do movimento e submetidos a SPECT encefálico com TRODAT, USTC e SST-16. Curvas Receiver Operating Characteristic (ROC) foram obtidas para definir os pontos de corte dos métodos avaliados para detecção de DP. RESULTADOS: Vinte indivíduos com DP (13 homens e 7 mulheres) e 9 participantes saudáveis foram admitidos no estudo. A idade mediana de início dos sintomas foi de 56,5 anos e a mediana do tempo de duração da doença foi de 5 anos. Maior área de ecogênica da substância negra (SN) foi observada no grupo com DP (p=0,013). Área ecogênica da SN de 0,22 cm2 foi definida pela curva ROC para detecção de DP, com acurácia de 79%. O ponto de corte do potencial de ligação do TRODAT no striatum foi 0,90, com acurácia de 99% para o diagnóstico de DP. Escore do SST-16 maior ou igual a 10 pontos foi o ponto de corte para detecção de DP, com acurácia de 85,8%. A combinação da USTC com teste da olfação levou à acurácia de 95% para detecção de DP. CONCLUSÃO: A combinação da USTC com SST-16 eleva a capacidade de ! detecção da DP. A acurácia da USTC combinada ao SST-16 para identificar pacientes com DP idiopática aproximou-se da acurácia do SPECT com TRODAT / INTRODUCTION: Diagnosing Parkinson\'s disease (PD) can be challenging, especially in the early stages of the disease. An accurate diagnosis requires more than clinical findings alone. Brain single-photon emission computed tomography (SPECT) and transcranial sonography (TCS) are helpful for diagnosing PD and differentiating it from atypical parkinsonian syndromes as well as essential tremor. This study aimed to investigate the accuracy of TCS combined with the Sniffin\' sticks olfactory test (SST-16) for differentiation between idiopathic PD patients and healthy controls compared to that of 99mTc-TRODAT-1 SPECT (TRODAT). METHODS: A cross-sectional study included PD patients diagnosed in accordance with United Kingdom PD Society Brain Bank criteria and a control group of age and sex-matched healthy subjects. All patients were examined by a movement disorder specialist and underwent brain SPECT using TRODAT, TCS examination and SST-16 test. Receiver Operating Characteristic (ROC) curves were used to calculate cut-off points for TCS, Striatal TRODAT binding potentials and SST-16. The area under the ROC curve determined the accuracy of the method. RESULTS: Twenty patients with PD (13 males and 7 females) and nine healthy subjects were included. Median age of PD onset was 56.5 years with median disease duration of 5 years. A larger substantia nigra (SN) echogenic area was observed in the PD group (p=0.013). SN echogenic area cut-off point of 0.22 cm2 was obtained from a ROC curve for PD diagnosis. Considering this cut-off point, TCS accuracy was estimated at 79.2% for PD diagnosis. The cut-off value of 0.90 for striatal TRODAT binding was associated with 99% accuracy for the diagnosis of PD. SST-16 values equal or greater than 10 points showed a 85.8% accuracy for PD diagnosis. Combination of both SST-16 and TCS improved the accuracy to 95% for PD diagnosis. CONCLUSION: Combined assessment of SST-16 and TCS are reliable and highly accurate for distinguishing PD patients from healthy controls. The accuracy of TCS combined with SST-16 for differentiation between idiopathic PD patients and healthy controls is similar to that of SPECT TRODAT

Page generated in 0.1283 seconds