• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • 4
  • Tagged with
  • 32
  • 32
  • 32
  • 32
  • 25
  • 25
  • 20
  • 12
  • 10
  • 10
  • 8
  • 6
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Apports de la TEP dans l'imagerie moléculaire des récepteurs sérotoninergiques 5-HT1A et 5-HT7

Lemoine, Laëtitia 04 March 2011 (has links) (PDF)
Le système sérotoninergique, impliqué dans plusieurs pathologies du système nerveux central, peut être exploré in vivo par l'imagerie TEP (tomographie par émission de positons). La recherche et la validation préclinique de radiotraceurs ciblant spécifiquement les récepteurs sérotoninergiques est donc cruciale. Au cours de ce travail, nous nous sommes intéressés à deux récepteurs sérotoninergiques pour lesquels nous avons développé des outils moléculaires pour leur imagerie fonctionnelle: (i) les récepteurs 5-HT1A et (ii) les récepteurs 5-HT7. (i) Les récepteurs 5-HT1A sont parmi les récepteurs à sérotonine les mieux décrits à l'heure actuelle. Cependant, si des radiotraceurs TEP sont déjà disponibles, ceux-ci sont des antagonistes qui se fixent indifféremment aux récepteurs 5-HT1A, couplés aux protéines G et fonctionnels, et aux récepteurs 5-HT1A, découplés et non fonctionnels. Nous avons donc proposé une stratégie originale de développement d'un agoniste 5- HT1A radiomarqué au fluor afin d'accéder à une imagerie des récepteurs fonctionnels. Deux molécules, le F15599 et le F13714, initialement développées pour leurs propriétés antidépressives par un partenaire industriel, ont été radiomarquées au fluor 18 puis ont été évaluées in vitro, ex vivo et in vivo chez le rat et le chat. Nos résultats montrent que le [18F]F13714 permet de visualiser de manière inédite les récepteurs 5- HT1A couplés aux protéines G. (ii) Le deuxième axe de cette thèse concerne les récepteurs 5-HT7, de découverte récente et proposés comme cible thérapeutique antidépressive. A l'inverse des récepteurs 5-HT1A, les récepteurs 5-HT7 ne disposent pas encore de radiotraceur TEP. Notre approche a consisté à sélectionner, à partir du pharmacophore du récepteur, quatre structures d'antagonistes 5-HT7, synthétisées par un laboratoire partenaire de chimie : le 2FP3, le 4FP3, le 2FPMP et le 4FPMP. Nos études radiopharmacologiques in vitro, ex vivo et in vivo nous ont conduit à retenir un radiotraceur, le [18F]2FP3. À l'issue de ce travail de thèse CIFRE, nous pouvons donc proposer deux radiotraceurs TEP originaux, ouvrant des perspectives inédites d'imagerie moléculaires de la neurotransmission 5-HT1A et 5-HT7 et dont nous envisageons la poursuite du développement comme radiopharmaceutiques cliniques
2

Variabilité de réponse aux anti TNF-alpha dans les rhumatismes inflammatoires : apport des marqueurs biologiques et d'imagerie. / Variability of response to anti-TNF alpha in inflammatory rheumatisms : contribution of biological markers and imaging

Mulleman, Denis 16 January 2009 (has links)
Il existe une variabilité interindividuelle de la relation dose - effet chez les patients atteints de maladies inflammatoires rhumatismales traités par les inhibiteurs du Tumor Necrosis Factor-alpha (TNF-a). Dans la première partie de cette thèse, la physiopathologie du TNF-a dans le processus inflammatoire est présentée. Ensuite, le travail se concentre sur la relation concentration-effet en utilisant la modélisation pharmacocinétique-pharmacodynamique (PK-PD) modèles. À la fin, après une discussion sur les biomarqueurs d'imagerie, la thèse traite de l'utilité d'une nouvelle technique permettant de détecter la réponse précoce au traitement, à savoir la tomographie par émission de positons (TEP). En résumé, ce travail décrit la relation PK-PD dans les maladies inflammatoires rhumatismales traitées par anticorps monoclonaux en utilisant les marqueurs cliniques et biologiques, et démontre également l'influence de fortes concentrations d'anticorps monoclonaux pour la maintenance au traitement. La TEP est une technique prometteuse pour identifier la réponse précoce aux antagoistes du TNF-a. / There is an interindividual variability of the dose - response relationship in patients with inflammatory rheumatic diseases treated by Tumor Necrosis Factor-alpha (TNF-a) inhibitors. In the first part of this thesis, the pathophysiology of TNF-a in inflammatory processes is presented. Then, the work focuses on the concentration-effect relationship using pharmacokinetic-pharmacodynamic (PK-PD) models. At the end, after discussion on imaging biomarkers, the thesis discusses the usefulness of a new technique to detect the early response to treatment, namely the positron emission tomography (PET). In summary, this work describes the PK-PD relationship in rheumatic inflammatory diseases treated by monoclonal antibodies using clinical and biological markers and demonstrates also the influence of high concentrations of monoclonal antibodies on maintenance to treatment. PET is a promising technique to identify early response to TNF-a antagonists.
3

Influence d’un régime riche en graisses sur un modèle de vieillissement « accéléré » : étude de la fonction et de la morphologie cardiaque, la fonction artérielle, le métabolisme et l’inflammation / Influence of a high-fat diet on an "accelerated" aging model : study of cardiac function and morphology, arterial function, metabolism and inflammation

Lambert, Delphine 06 December 2016 (has links)
L’obésité et le surpoids ont été décrits comme une pandémie. L’obésité et le vieillissement vont conduire à des complications cardiovasculaires. De plus, l’obésité favoriserait un vieillissement cardiaque prématuré chez les adultes jeunes. L’hypothèse de ce travail est qu’un régime riche en graisses, démarré avant l’âge adulte, poursuivi sur une longue durée, pourrait entraîner un vieillissement « accéléré » cardiovasculaire et métabolique. Nous avons démontré, dans un modèle murin vieillissant, qu’un régime riche en graisses conduit à des troubles métaboliques ainsi qu’à une augmentation de la masse grasse et à une détérioration du métabolisme au niveau du tissu adipeux blanc. Ces troubles sont associés à des altérations au niveau cardiaque, malgré l’absence de modifications de la pression artérielle et de la fréquence cardiaque. Le vieillissement, chez les souris obèses, va conduire à un remodelage du ventricule gauche accompagné par une dysfonction systolique. Au niveau tissulaire cardiaque, le vieillissement et le régime précoce conduisent à l’augmentation de l’expression de gènes de fibrose confirmant ainsi le phénotype hypertrophique. Le vieillissement associé à un régime riche en graisses précoce conduit également à une up-régulation de GDF11. GDF11 peut alors être considéré comme un marqueur de vieillissement cardiaque accéléré. Ces résultats peuvent suggérer des voies thérapeutiques ou préventives, où l’inhibition de GDF11 améliorerait le pronostic et la survie cardiovasculaire des sujets obèses. L’étude de ce modèle nous a ainsi permis de mettre en évidence qu’un régime riche en graisses conduit à un vieillissement accéléré au niveau cardiaque / Obesity and being overweight have been described as a global pandemic. Both obesity and aging will lead to cardiovascular complications. In addition, it has been highlighted that obesity promotes premature cardiac aging in young adults. The hypothesis of this work is that a high fat diet begun before adulthood, pursued over a long period of time, could lead to “accelerated” cardiovascular and metabolic aging. We have demonstrated, in an aging mouse model, that an early high fat diet leads to metabolic disorders and to an increase in fat mass and a deterioration in metabolism of white adipose tissue. These disorders are associated with alterations in cardiac morphology and function, despite an absence of changes in blood pressure and heart rate. Ageing, in obese mice, leads to ventricular remodeling accompanied by systolic dysfunction. In cardiac tissue, aging and early diet lead to an increased expression of fibrosis genes confirming the hypertrophic phenotype. Aging associated with an early high fat diet led also to an up-regulation of GDF11. GDF11 may then be considered as a marker of accelerated cardiac aging. These results may suggest therapeutic or preventive pathways, where inhibition of GDF11 improves prognosis and survival in obese subjects with cardiovascular disease. The study of this model has allowed us to demonstrate that a high fat diet leads to accelerated aging at the level of the heart
4

Estimation de la fonction d’entrée en tomographie par émission de positons dynamique : application au fluorodesoxyglucose / Estimation of the input function in dynamic positron emission tomography applied to fluorodeoxyglucose

Jouvie, Camille 06 December 2013 (has links)
La tomographie par émission de positons (TEP) est une méthode d’imagerie fonctionnelle, utilisée en particulier lors du développement de nouveaux médicaments et pour imager les tumeurs. En TEP, l’estimation de la concentration plasmatique artérielle d’activité du traceur non métabolisé (nommée « fonction d’entrée ») est nécessaire pour l’extraction des paramètres pharmacocinétiques. Ceux-ci permettent de quantifier le comportement du traceur dans les tissus, ou plus précisément le traitement du traceur par les tissus. Cette thèse constitue une contribution à l’étude de la fonction d’entrée, par l’élaboration d’une méthode d’estimation de la fonction d’entrée peu invasive à partir des images TEP et de prélèvements veineux. L’exemple du traceur FDG (analogue du glucose) dans le cerveau humain a été choisi. La méthode proposée repose sur la modélisation compartimentale de l’organisme : elle déconvolue le modèle à trois compartiments utilisé pour le FDG. L’originalité de la méthode repose sur trois points : l’utilisation d’un grand nombre de régions d’intérêt ; l’utilisation d’un grand nombre de jeux de trois régions d’intérêt différentes; une estimation itérative. Pour la validation de la méthode, un soin particulier a été porté à la simulation d’images TEP (simulation d’acquisition, reconstruction, corrections) de plus en plus réalistes, depuis une image simple simulée avec un simulateur analytique jusqu’à une image la plus proche possible de la réalité, simulée avec simulateur Monte-Carlo. Une chaîne de pré-traitement (segmentation des IRM associés, recalage entre images TEP et IRM et correction de l’effet de volume partiel par une variante de la méthode de Rousset) a ensuite été appliquée à ces images afin d’extraire les cinétiques des régions d’intérêt, données d’entrée de la méthode d’estimation de la fonction d’entrée. L’évaluation de la méthode sur différentes données, simulées et réelles, est présentée, ainsi que l’étude de la sensibilité de la méthode à différents facteurs tels que les erreurs de segmentation, de recalage, de mesure de l’activité des prélèvements sanguins. / Positron Emission Tomography (PET) is a method of functional imaging, used in particular for drug development and tumor imaging. In PET, the estimation of the arterial plasmatic activity concentration of the non-metabolized compound (the "input function") is necessary for the extraction of the pharmacokinetic parameters. These parameters enable the quantification of the compound dynamics in the tissues. This PhD thesis contributes to the study of the input function by the development of a minimally invasive method to estimate the input function. This method uses the PET image and a few blood samples. In this work, the example of the FDG tracer is chosen. The proposed method relies on compartmental modeling: it deconvoluates the three-compartment-model. The originality of the method consists in using a large number of regions of interest (ROIs), a large number of sets of three ROIs, and an iterative process. To validate the method, simulations of PET images of increasing complexity have been performed, from a simple image simulated with an analytic simulator to a complex image simulated with a Monte-Carlo simulator. After simulation of the acquisition, reconstruction and corrections, the images were segmented (through segmentation of an IRM image and registration between PET and IRM images) and corrected for partial volume effect by a variant of Rousset’s method, to obtain the kinetics in the ROIs, which are the input data of the estimation method. The evaluation of the method on simulated and real data is presented, as well as a study of the method robustness to different error sources, for example in the segmentation, in the registration or in the activity of the used blood samples.
5

Apports de la TEP dans l’imagerie moléculaire des récepteurs sérotoninergiques 5-HT1A et 5-HT7 / Contributions of PET in molecular imaging of 5-HT1A and 5-HT7 serotonin receptors

Lemoine, Laëtitia 04 March 2011 (has links)
Le système sérotoninergique, impliqué dans plusieurs pathologies du système nerveux central, peut être exploré in vivo par l’imagerie TEP (tomographie par émission de positons). La recherche et la validation préclinique de radiotraceurs ciblant spécifiquement les récepteurs sérotoninergiques est donc cruciale. Au cours de ce travail, nous nous sommes intéressés à deux récepteurs sérotoninergiques pour lesquels nous avons développé des outils moléculaires pour leur imagerie fonctionnelle: (i) les récepteurs 5-HT1A et (ii) les récepteurs 5-HT7. (i) Les récepteurs 5-HT1A sont parmi les récepteurs à sérotonine les mieux décrits à l’heure actuelle. Cependant, si des radiotraceurs TEP sont déjà disponibles, ceux-ci sont des antagonistes qui se fixent indifféremment aux récepteurs 5-HT1A, couplés aux protéines G et fonctionnels, et aux récepteurs 5-HT1A, découplés et non fonctionnels. Nous avons donc proposé une stratégie originale de développement d’un agoniste 5- HT1A radiomarqué au fluor afin d’accéder à une imagerie des récepteurs fonctionnels. Deux molécules, le F15599 et le F13714, initialement développées pour leurs propriétés antidépressives par un partenaire industriel, ont été radiomarquées au fluor 18 puis ont été évaluées in vitro, ex vivo et in vivo chez le rat et le chat. Nos résultats montrent que le [18F]F13714 permet de visualiser de manière inédite les récepteurs 5- HT1A couplés aux protéines G. (ii) Le deuxième axe de cette thèse concerne les récepteurs 5-HT7, de découverte récente et proposés comme cible thérapeutique antidépressive. A l’inverse des récepteurs 5-HT1A, les récepteurs 5-HT7 ne disposent pas encore de radiotraceur TEP. Notre approche a consisté à sélectionner, à partir du pharmacophore du récepteur, quatre structures d’antagonistes 5-HT7, synthétisées par un laboratoire partenaire de chimie : le 2FP3, le 4FP3, le 2FPMP et le 4FPMP. Nos études radiopharmacologiques in vitro, ex vivo et in vivo nous ont conduit à retenir un radiotraceur, le [18F]2FP3. À l’issue de ce travail de thèse CIFRE, nous pouvons donc proposer deux radiotraceurs TEP originaux, ouvrant des perspectives inédites d’imagerie moléculaires de la neurotransmission 5-HT1A et 5-HT7 et dont nous envisageons la poursuite du développement comme radiopharmaceutiques cliniques / The serotonergic system, implicated in several diseases of central nervous system, can be explored in vivo by PET imaging (positron emission tomography). The research and the preclinical validation of radiotracers that specifically target serotonin are crucial. In this work, we focused on two serotonin receptors for which we have developed molecular tools for functional imaging: (i) the 5-HT1A and (ii) the 5-HT7. (i) 5-HT1A receptors are among the serotonin receptors the best described at present. However, if PET radiotracers are already available, they are antagonists and bind either to 5-HT1A receptors, G protein-coupled and functional, and to 5-HT1A receptors decoupled and non-functional. We therefore proposed an original strategy to develop a 5-HT1A agonist labeled with fluorine to access imagery of functional receptors. Two molecules, the F15599 and F13714, initially developed for their antidepressant properties by an industrial partner, were radiolabeled with fluorine-18 and were evaluated in vitro, ex vivo and in vivo in rats and cats. Our results show that the [18F] F13714 may view in a new way the 5-HT1A G protein-coupled (ii) The second focus of this thesis for the 5-HT7, recently discovered and proposed as a therapeutic target antidepressant. Unlike the 5-HT1A, 5-HT7 receptors do not yet have PET radiotracer. Our approach was to select, from the pharmacophore of the receptor, four structures of 5-HT7 antagonists, synthesized by a lab partner in chemistry: the 2FP3, the 4FP3, the 2FPMP and 4FPMP. Our radiopharmacology in vitro, ex vivo and in vivo led us to retain a radiotracer, the [18F] 2FP3. At the conclusion of this thesis CIFRE, we can propose two originals PET radiotracers , opening new perspectives for molecular imaging of neurotransmission of 5-HT1A and 5-HT7 receptors and which we plan further development as clinical radiopharmaceuticals
6

OPTIMISATION DE LA RECONSTRUCTION COMPLÈTE 3D EN TOMOGRAPHIE PAR ÉMISSION DE POSITONS DU PETIT ANIMAL PAR MODÉLISATION MONTE-CARLO DE LA MATRICE SYSTÈME

Merheb, Charbel 25 September 2007 (has links) (PDF)
La qualité des images en TEP est directement liée à l'algorithme de reconstruction utilisé. Les méthodes de reconstruction statistiques peuvent modéliser, via la matrice système, les différents phénomènes physiques qui détériorent la qualité des images. Notre approche consiste d'une part, à modéliser les différents phénomènes géométriques et physiques, au moyen de l'outil de simulation Monte-Carlo, et d'autre part, à exploiter les données dans un format "mode-liste" présentant de nombreux avantages, afin de les reconstruire à l'aide d'un algorithme de reconstruction 3D. Cette méthode, appelée SIMALIR, a été appliquée et étudiée sur la caméra MOSAIC(TM) de Philips, système TEP dédié au petit animal qui a fait l'objet d'une modélisation à l'aide de la plateforme GATE. Les principales performances du modèle simulé et particulièrement la distribution spatiale ont été testées et validées, afin de pouvoir les exploiter dans la modélisation de la matrice système. Les résultats précliniques et sur des objets tests ont montré que la méthode SIMALIR permet d'améliorer considérablement la qualité des images reconstruites par rapport aux programmes de reconstruction classiques.
7

Estimation de la fonction d'entrée en tomographie par émission de positons dynamique : application au fluorodesoxyglucose

Jouvie, Camille 06 December 2013 (has links) (PDF)
La tomographie par émission de positons (TEP) est une méthode d'imagerie fonctionnelle, utilisée en particulier lors du développement de nouveaux médicaments et pour imager les tumeurs. En TEP, l'estimation de la concentration plasmatique artérielle d'activité du traceur non métabolisé (nommée " fonction d'entrée ") est nécessaire pour l'extraction des paramètres pharmacocinétiques. Ceux-ci permettent de quantifier le comportement du traceur dans les tissus, ou plus précisément le traitement du traceur par les tissus. Cette thèse constitue une contribution à l'étude de la fonction d'entrée, par l'élaboration d'une méthode d'estimation de la fonction d'entrée peu invasive à partir des images TEP et de prélèvements veineux. L'exemple du traceur FDG (analogue du glucose) dans le cerveau humain a été choisi. La méthode proposée repose sur la modélisation compartimentale de l'organisme : elle déconvolue le modèle à trois compartiments utilisé pour le FDG. L'originalité de la méthode repose sur trois points : l'utilisation d'un grand nombre de régions d'intérêt ; l'utilisation d'un grand nombre de jeux de trois régions d'intérêt différentes; une estimation itérative. Pour la validation de la méthode, un soin particulier a été porté à la simulation d'images TEP (simulation d'acquisition, reconstruction, corrections) de plus en plus réalistes, depuis une image simple simulée avec un simulateur analytique jusqu'à une image la plus proche possible de la réalité, simulée avec simulateur Monte-Carlo. Une chaîne de pré-traitement (segmentation des IRM associés, recalage entre images TEP et IRM et correction de l'effet de volume partiel par une variante de la méthode de Rousset) a ensuite été appliquée à ces images afin d'extraire les cinétiques des régions d'intérêt, données d'entrée de la méthode d'estimation de la fonction d'entrée. L'évaluation de la méthode sur différentes données, simulées et réelles, est présentée, ainsi que l'étude de la sensibilité de la méthode à différents facteurs tels que les erreurs de segmentation, de recalage, de mesure de l'activité des prélèvements sanguins.
8

Détecteur liquide multipixellisé, pour l’imagerie médicale et préclinique / Multipixel liquid ionization detector for medical imaging

Mancardi, Xavier 29 September 2016 (has links)
Le projet CaLIPSO (Calorimètre Liquide Ionisation Position Scintillation Organométallique) a pour ambition de mettre au point un détecteur de γ 511 keV très efficace et très rapide pour la tomographie par émission de positons. Pour cela nous utilisons comme milieu de détection un nouveau liquide, le TMBi (TriMéthylBismuth). Dans le TMBi, l’interaction de photons γ produit des photons optiques et des paires électrons-ions. Le but de cette thèse est de mesurer les paramètres d’ionisation du TMBi et de construire, un détecteur de charge instrumentant efficacement ce liquide, et son électronique associée. Afin de pouvoir détecter les électrons libres créés par l’ionisation du liquide, celui-ci doit être ultrapur, c’est-à-dire débarrassé de tout composé électronégatif qui pourraient capturer les électrons et diminuer le signal. Ceci a été travaillé à l’aide de tamis moléculaires. Les signaux à détecter sont très faibles (fA, fC). Ainsi, l’environnement de l’expérience et le détecteur ont été développés pour des mesures très bas bruit (niveaux de bruit mesurés inférieurs à 10 fA et 200 électrons). Nous avons travaillé à mesurer le rendement d’ionisation (ou Gfi) qui quantifie le rendement de production de charge dans le liquide, la mobilité des électrons dans le TMBi et la résolution en énergie du détecteur. Ce sont les principaux paramètres permettant de valider l’utilisation de TMBi pour l’imagerie TEP. Les futurs développements comprennent la mise en œuvre d’un détecteur densément pixellisé et l’optimisation de la résolution en énergie. / The CALIPSO project (Calorimètre Liquide Ionisation Position Scintillation Organométallique) aims to develop a very efficient and very fast 511 keV γ detector for positron emission tomography. For this we use an organometallic liquid for the detection medium, the TMBi (TriMéthylBismuth). In TMBi, the interaction of a γ photon produces optical photons and electron-ion pairs.The aim of this thesis is to measure the ionization parameters of the liquid TMBi and build an efficient charge detector and its associated electronics.In order to detect the free electrons created by the ionization in the liquid, this liquid must be highly pure (which means free of any electronegative compound which could capture electrons and reduce the signal). This has been worked on using molecular sieves.The signals to be detected are very weak (fA, fC). Thus, the test setup and detector were developed for very low noise measurements (measured noise levels below 10 fA and 200 electrons).We measured the ionization yield (or Gfi) which quantifies the charge production yield in the liquid, the electrons mobility in the TMBi and the energy resolution of the detector. These are the main parameters to validate the use of TMBi for PET imaging.Future developments include the implementation of a pixelated detector and optimization of the detector energy resolution.
9

Brain energy metabolism in older adults : implications for the risk of age-related cognitive decline / Métabolisme énergétique du cerveau chez les personnes âgées : implications pour le risque de déclin cognitif lié au vieillissement

Nugent, Scott January 2014 (has links)
Abstract : Normal aging is accompanied by several metabolic and structural changes in the brain and a heightened risk of cognitive decline. These brain changes may increase the chances of later developing Alzheimer’s disease. The first major objective of the present work was to quantify, through positron emission tomography (PET) and volumetric magnetic resonance (MR) imaging techniques, the effects of normal aging on brain metabolism and structure. Our results indicate that brain glucose hypometabolism can be present in older individuals who remain cognitively normal. Cognitive status was assessed using age-normalised neuropsychological tests. Brain glucose hypometabolism was quite specific and affected primarily the prefrontal cortex and the caudate nucleus. Due to the high variation in plasma ketones, brain ketone hypometabolism per se was not present in older persons (≥65 years old). However, a lower rate constant for brain ketone uptake was fairly widespread in our healthy older group. Lower regional brain volume during normal aging was widespread throughout the cortex and was more apparent than cortical thickness loss. The second major objective was to characterize brain ketone and glucose metabolism in the context of mild Alzheimer’s disease. Glucose hypometabolism in Alzheimer’s disease was present in the temporoparietal cortex when compared with cognitively normal older adults. However, no significant differences in brain ketone metabolism or rate constant were found between the two groups. Alternative energy sources to glucose may therefore be beneficial to the Alzheimer’s disease brain, at least early in the disease process, in order to maintain neuronal capacity and limit synaptic loss and decline in memory and cognition. // Résumé : Au cours du vieillissement normal, le cerveau va subir plusieurs changements métaboliques et structuraux qui vont accroitre le risque de déclin cognitif et du fait même augmenter le risque de développer la maladie d’Alzheimer. Les objectifs du présent travail étaient de : 1) quantifier l’effet du vieillissement normal sur la structure et le métabolisme du cerveau, grâce aux techniquesd’imagerie tomographie par émission de positons et l’imagerie par résonance magnétique ; 2) caractériser le métabolisme cérébral des deux substrats énergétiques du cerveau, le glucose et les cétones, dans un contexte de la maladie d’Alzheimer. Nos résultats indiquent qu’un hypométabolisme du glucose est présent chez des personnes âgées (65 ans et plus) qui démontrent pourtant une cognition normale. Cette diminution du métabolisme cérébral du glucose est observée spécifiquement au niveau des régions du cortex préfrontal et du noyau caudé. Du fait d’une grande variabilité au niveau des concentrations plasmatiques en cétones, aucune diminution du métabolisme des cétones n’a été constatée chez les personnes âgées. En revanche, la constante de transfert des cétones au cerveau était globalement diminuée. En ce qui concerne l’atrophie cérébrale au cours du vieillissement normal, nous avons observé qu’elle était globale, qu’elle concerne l’ensemble du cerveau et qu’elle était plus marquée que la diminution de l’épaisseur corticale. En comparant des personnes âgées en bonne santé à des personnes ayant la maladie d’Alzheimer, nous avons également confirmé que chez ces dernières, le métabolisme du glucose est diminué spécifiquement au niveau du cortex temporopariétal. Cependant, aucune différence entre les deux groupes de personnes n’a été observée en ce qui concerne le métabolisme cérébral des cétones. Ainsi en fournissant des substrats énergétiques autres que le glucose, il serait donc possible de maintenir les capacités neuronales, limiter la perte synaptique et ralentir le déclin cognitif. Ceci pourrait constituer une stratégie prometteuse dans la prévention et le traitement complémentaire au début de la maladie d’Alzheimer.
10

Evaluation de l’integration des donnees issues de la tomographie par emission de positons en radiotherapie : application à deux modèles cliniques : les cancers ORL et les cancers pulmonaires / Assessment of the integration of positron emission tomography data in radiotherapy : application through two clinical model the head-and-neck cancers and the pulmonary cancers : the head-and-neck cancers and the pulmonary cancers

Henriques de Figueiredo, Bénédicte 17 December 2013 (has links)
Objectif : Etudier l’impact volumétrique et dosimétrique de l’intégration des données de tomographie par émission de positons (TEP) en radiothérapie (RT) à travers deux modèles cliniques : les cancers oto-rhino-laryngologiques (ORL) et les cancers pulmonaires. Matériel et méthodes : Pour les cancers ORL, après un travail préalable sur fantôme pour mise au point d’une méthode de segmentation automatique par seuillage adaptatif, deux séries de neuf et 15 patients présentant un cancer ORL traité par RT, ont bénéficié d’une TEP respectivement au 18F-Fluorodeoxyglucose (18F-FDG) et au 18F-Fluoromisonidazole (18F-FMISO), traceur de l’hypoxie. Les modifications volumétriques et dosimétriques induites par ces examens ont été analysées. Pour le 18F-FMISO, différents temps d’acquisition et différentes méthodes de segmentation ont également été étudiés. Pour les cancers pulmonaires, l’impact sur la RT d’une TEP-4D au 18F-FDG avec correction des effets de volume partiel (EVP) et application de différentes méthodes de segmentation, a été évalué à travers l’analyse des sept premiers patients inclus dans le protocole PULMOTEP, promu par le CHU de Bordeaux. Résultats : Pour les cancers ORL, la TEP au 18F-FDG a conduit à une réduction des volumes de RT de 40% tout en individualisant des zones de « mismatch » entre TEP et scanner. Pour la TEP au 18F-FMISO, un meilleur contraste des images était retrouvé à 4h. Cependant, les volumes segmentés à 3 et 4h n’étaient pas significativement différents, permettant d’envisager en pratique courante des acquisitions moins tardives à 3h. L’utilisation d’une TEP au 18F-FMISO permettait d’envisager la réalisation d’une « escalade de dose » sur les zones hypoxiques avec une augmentation du taux de probabilité de contrôle tumoral de 18,1% sans augmentation excessive de la toxicité. Pour les cancers pulmonaires, il n’était pas retrouvé d’impact de la correction du mouvement respiratoire, un seul patient sur les sept étudiés présentant une tumeur mobile. Un impact constant de la correction des EVP était par contre retrouvé avec une augmentation de l’activité tumorale maximale de 27% et une diminution des volumes segmentés de 15%.Conclusion : Pour les cancers ORL, la validation de ces résultats nécessite la réalisation d’études cliniques. Pour les cancers pulmonaires, l’utilisation d’une TEP-4D avec correction du mouvement respiratoire doit être envisagée au cas par cas. L’implémentation en clinique de logiciels de correction des EVP semble, par contre, à encourager. / Objective: To study the impact of Positron Emission Tomography (PET) data on radiotherapy (RT) planning through two clinical models: the head-and-neck cancers (HNC) and the pulmonary cancers. Methods and Materials: For HNC, after a previous phantom study in order to determinate an automatic segmentation method with adaptive thresholding, two series of nine and 15 patients selected for RT, underwent PET with 18F-Fluorodeoxyglucose (FDG) and 18F-Fluoromisonidazole (FMISO). The impact on RT target volumes (TV) and dosimetries was evaluated. For FMISO-PET, several time acquisitions and several segmentation methods were assessed. For pulmonary cancers, the use of a four-dimensional (4D) FDG-PET with partial volume effect (PVE) correction and several segmentation methods was evaluated through the first seven patients enrolled in the PULMOTEP protocol performed by the CHU of Bordeaux. Results: For HNC, FDG-PET led to a RT TV reduction of 40%, with mismatches between PET and CT data. For FMISO-PET images, a better contrast was obtained 4h after FMISO injection. However, segmented volumes obtained at 3 and 4h were not statistically different allowing PET- acquisitions at 3h in routine clinical practice. The use of FMISO-PET allows considering « dose escalation » on hypoxic TV with an increase of tumour control probability by 18,1% without excessive increase of toxicities. For pulmonary cancers, there was no impact of the respiratory motion correction but only one patient on seven presented a mobile tumour. PVE correction had impact on RT TV with an increase of the maximal tumoural activity by 27% and a volume reduction of 15%. Conclusion: For HNC, the validation of these results needs clinical and prospective studies. For pulmonary cancers, the use of 4D-PET must be decided case by case. On the other side, the implementation of automatic software for PVE correction seems interesting.

Page generated in 0.135 seconds