• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 15
  • 11
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Imagens tomográficas tridimensionais dos ossos da cabeça de gatos domésticos aplicadas ao ensino do diagnóstico por imagem /

Zanatta, Rosana. January 2010 (has links)
Orientador: Júlio Carlos Canola / Banca: Tilde Rodrigues Froes / Banca: Nadia Cristina Borges / Banca: Mário Roberto Hatayde / Banca: Paola Castro Moraes / Resumo: A proposta deste estudo foi estabelecer um método de ensino para a disciplina de diagnóstico por imagem veterinária, ao associar o uso de imagens tridimensionais às aulas convencionais de radiologia. Para este fim foram obtidas imagens tridimensionais, por meio de exames de tomografia computadorizada multidetectores, da cabeça de cinco gatos domésticos. Estas imagens foram adicionadas à aula de radiologia da cabeça, onde comumente são apresentadas imagens bidimensionais. A aula foi ministrada para alunos de três instituições de ensino superior, uma federal, uma estadual e outra particular. Após a apresentação, os alunos responderam a um questionário para que fosse possível verificar se o método contribuiu para assimilar com mais facilidade o conhecimento anatômico e radiográfico regional. Dos 100 alunos, 77% acharam o método totalmente satisfatório, 19% satisfatório, 2% moderadamente satisfatório, 2% pouco satisfatório. Nenhum aluno considerou o método insatisfatório, validando o método proposto. Como objetivo secundário discutiram-se as imagens tridimensionais obtidas, com enfoque anatomo-clínico, visando tornar mais atrativo o estudo da anatomia radiográfica dos ossos da cabeça. As imagens permitiram a identificação dos ossos e das cavidades da cabeça. Acredita-se que estas possam ser utilizadas no estudo das estruturas frequentemente acometidas por enfermidades em gatos domésticos / Abstract: The aim of this study was to establish a teaching methodology for diagnostic imaging in veterinary medicine by correlating the use of three-dimensional images to conventional radiology lectures. For this purpose, threedimensional images of the head of five domestic cats were acquired by multi-detector row computed tomography. These images were added to the lecture of radiology of the head, in which two-dimensional images are usually presented. The lecture was presented to students of three different institutions (federal, state and private). After the lecture the students answered a questionnaire to verify if the method contributed for better assimilation of the anatomical and radiographic knowledge. From 100 students, 77% found the method highly satisfactory, 19% satisfactory, 2% moderately satisfactory, 2% poorly satisfactory. None of the students found the method unsatisfactory. Threedimensional images obtained had been discussed with an anatomical and clinical view to make the study of radiographic anatomy of the bones of the head more attractive to students. The images allowed the identification of bones and cavities of the head, being able to be used to study the structures that are frequently affected by diseases in domestic cats / Doutor
12

Estudo dos aspectos anatômicos da articulação temporo-hióide de equinos por meio da radiografia convencional, ultrassonografia articular e tomografia computadorizada /

Santos, Taízha Cristine Ciasca dos. January 2009 (has links)
Orientador: Luiz Carlos Vulcano / Banca: Ana Liz Garcia Alves / Banca: Joffre Guazzelli Filho / Banca: Stefano Carlo Filippo Hagen / Banca: Masao Iwasaki / Resumo: Este estudo teve como objetivo, utilizando para tanto 22 cabeças de cadáveres equinos sadios, obtidas em abatedouro frigorífico, avaliar comparativamente de forma minuciosa e detalhada a anatomia da articulação temporo-hióide de equinos, por meio do exame radiográfico convencional, ultrassonográfico articular e tomográfico. Ambas as articulações, direita e esquerda, foram avaliadas. As imagens obtidas pelos três métodos foram identificadas e agrupadas sob aspecto das imagens que se repetem, que se somam e que se complementam, além da realização de avaliação minuciosa das características anatômicas da articulação temporo-hióide como um todo pelos diferentes acessos diagnósticos, buscando o meio de diagnóstico menos agressivo, não invasivo, rápido e de relativo baixo custo quando comparados. Observou-se que a tomografia visibilizou sempre de forma clara, ou seja, com melhor qualidade e precisão, todas as características e estruturas avaliadas. Já o raios-x e a ultrassononografia variaram bastante, algumas vezes de forma positiva, em concordância com a tomografia, outras nem tanto, limitando a avaliação de determinadas estruturas por estes métodos. Os três métodos de diagnóstico demonstraram uma concordância plena significativa (93,18%) apenas em relação à sua localização anatômica, o que não significa que os três métodos não podem gerar informações adicionais de grande valia. Concluiu-se que a TC é superior aos outros métodos, porém os três podem ser aliados no sentido de que se complementam, repetindo e somando imagens e informações importantes na escolha de um tratamento e na avaliação de seu prognóstico. Estes resultados propõem referências de abordagem que adicionarão informações na avaliação da região da articulação temporo-hióide dos equinos. / Abstract: Twenty-two equine heads obtained from healthy slaughtered horses were analyzed through conventional radiography, articular ultrasonography and Computed Tomography (CT). Both left and right joints were evaluated. Images obtained by the three methods were identified and grouped according to different aspects: repeated images, added images and complementary images. In addition, images were thoroughly evaluated for anatomical characteristics of the temporohyoid joint as a whole by the different diagnostic accesses, in an attempt to obtain a less aggressive, non-invasive, fast and relatively inexpensive diagnosis. Tomography always showed the evaluated characteristics and structures very clearly, i.e., with better quality and precision. In contrast, x-ray and ultrasonography varied significantly, sometimes positively, in agreement with tomography, and in other instances negatively, limiting the evaluation of certain structures by those methods. The three diagnostic methods showed a significant concordance (93.18%) only in relation to the anatomical localization. This, however, does not mean that the three methods may not generate additional useful information. It was concluded that CT is a superior method than the others, although the three methods are complementary and can be combined, by repeating and adding important images and information when choosing a treatment and in the evaluation of the prognostics. These results define a reference of access that will add information in the evaluation of the equines temporohyoid joint. tomography, articular ultrasonography. / Doutor
13

Avaliação das reações adversas agudas após administração endovenosa de contraste iodado iônico e não-iônico em hospital oncológico /

Cremonini, Camila do Carmo Rodrigues. January 2010 (has links)
Orientador: Euclides Timótio da Rocha / Banca: Fabiano Rubião Lucchesi / Banca: Jorge Elias Junior / Resumo: Avaliar a ocorrência e a gravidade das reações adversas agudas (RAA) com o uso do meio de contraste iodado iônico e não-iônico nos pacientes submetidos ao exame de tomografia computadorizada (TC) em hospital nacional terciário oncológico e avaliar neoplasia como possível risco para RAA. Secundariamente, avaliar o impacto do uso seletivo do meio de contraste iodado nos custos. Pacientes submetidos à TC com contraste iodado entre outubro de 2007 e agosto de 2008 foram avaliados quanto à ocorrência e à gravidade das reações adversas agudas aos meios de contrastes iônicos e nãoiônicos. As reações foram categorizadas em leve, moderada ou grave de acordo com o tipo dos sinais e sintomas e classificadas como agudas pelo tempo de ocorrência, desde o momento da injeção até 30 minutos após. Os testes do quiquadrado e exato de Fisher foram utilizados para análise estatística da ocorrência de RAA em relação às variáveis de gênero e idade. O estudo foi aprovado pelo Comitê de Ética local e o Termo de Consentimento Livre Esclarecido foi obtido. Houve 78 RAA ao contraste iodado iônico e 11 ao não-iônico, com uma ocorrência global de 3,3% (78/2.339) e 0,5% (11/2.216), respectivamente. A maioria das reações foi classificada como leve em ambos os grupos, representando 91% (71) no grupo iônico e 81,8% (9) no grupo não-iônico. As demais reações foram do tipo moderada não havendo nenhuma reação grave. Em relação ao início das RAA, 71% e 73% (iônico e não-iônico) ocorreram nos primeiros 5 minutos. A freqüência de RAA no grupo em que recebeu contraste iônico foi maior no sexo feminino (p < 0,001). No grupo não-iônico não houve diferença estatisticamente significativa entre os sexos (p = 1,0). Não houve associação entre a presença de reação aguda e as faixas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To evaluate the occurrence and severity of acute adverse reactions (AAR) to iodinated ionic and non-ionic contrast media in patients undergoing computerized tomography (CT) at a national tertiary cancer hospital and to evaluate neoplasm as a possible risk for AAR. Secondly, to assess the impact of selective use of iodinated contrast agent costs. Patients who underwent contrast-enhanced CT between October 2007 and August 2008 were evaluated for the presence and severity of acute adverse reactions to ionic and non-ionic contrast media. The reactions were categorized as mild, moderate or severe according to the type of signs and symptoms and classified as acute by the time of occurrence, from the time of the injection up to 30 minutes afterwards. The chi-square and Fisher's exact were used for statistical analysis of the occurrence of AAR for the variables of gender and age. The study was approved by the local Ethics Committee and informed consent was obtained. There were 78 AAR to ionic iodinated contrast and 11 to non-ionic, with an overall occurrence of 3.3% (78/2339) and 0.5% (11/2216), respectively. Most reactions were classified as mild in both groups, representing 91% (71) in the ionic group and 81.8% (9) in the non-ionic group. All other reactions were moderate and there were no severe reactions. Regarding onset of AAR, 71% and 73% (ionic and non-ionic group) occurred in the first five minutes. The occurrence of AAR in the group who received ionic contrast was higher in females (p <0.001). As for the non-ionic group, there was no significant statistical difference between genders (p = 1.0). There was no association between the presence of acute reaction and the age groups of the population in the ionic contrast group. For the non-ionic group, no statistical analysis was performed as the sample was deemed reduced. Among... (Complete abstract click electronic access below) / Mestre
14

Análise tomográfica Cone Beam e histológica do preparo do canal radicular com três sistemas rotatórios /

Moraes, Sergio Herrero. January 2010 (has links)
Orientador: Marcelo Gonçalves / Banca: Yara Teresinha Correa Silva Sousa / Banca: Ivaldo Gomes de Moraes / Banca: Fábio Luiz Camargo Villela Berbert / Banca: Mario Tanomaru Filho / Resumo: O presente estudo teve como objetivos as análise tomográfica e histológica do preparo do canal radicular com três sistemas rotatórios de NiTi: ProTaper (grupo 1), Mtwo (grupo 2) e K3 (grupo 3). Trinta e seis molares superiores foram radiografados pela técnica de tomografia cone beam (feixe cônico) antes e depois do preparo rotatório do canal mésio-vestibular. Os dentes foram pesados antes e depois do preparo para analisar a capacidade de corte dos instrumentos pela remoção de dentina. Aumento na área do canal, no alargamento do comprimento mésio-distal do canal, centralização e transporte do canal nos terços cervical, médio e apical foram analisadas nas tomografias computadorizadas transferidas para o software Canvas 11. Após o preparo dos canais radiculares as raízes foram descalcificadas, cortadas com 6 μm de espessura e coradas com hematoxilina-eosina, para exame das irregularidades das paredes de dentina do canal radicular e da presença de resíduos no canal. Para avaliar estatisticamente os resultados foi utilizado o método de variância (ANOVA).Os resultados revelaram que houve diferença estatisticamente significante entre os grupos. ProTaper removeu significativamente mais dentina do que Mtwo e K3 (p<0,05). Mtwo removeu mais do que o K3 (p<0,05). Protaper, Mtwo e K3 aumentaram significativamente a área do canal depois do preparo (p<0,05). A diferença foi significativa no terço cervical entre ProTaper e K3 (p<0,05), Mtwo e K3; terço médio entre ProTaper e K3 (p<,0,05), Mtwo e K3 (p<0,05); no terço apical entre ProTaper e K3 (p<0,05), Mtwo e K3.p<0,05). Protaper, Mtwo e K3 aumentaram significativamente o comprimento mésio-distal do canal. A diferença foi significativa entre ProTaper e K3 (p<0,05) , Mtwo e K3 nos terços cervical, médio e apical. Na avaliação da centralização do canal foi encontrada diferença significativa de desvio entre os grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The key goal of the present study was the histological and tomographic analysis of the root canal preparation with three NiTi rotatory systems: ProTaper (group 1), Mtwo (group 2) e K3 (group 3). Thirty six maxillary molar teeth were radiographed with the cone beam technique before and after the mesial-buccal root canal preparation. The teeth were weighted before and after preparation to analyse dentine removal capacity of the cutting instruments. Images from computed tomography were transferred to the software Canvas 11 to allow for analysis of the increase of the root canal area, the widening of the mesial-distal distance, and the root canal centring and transport in the cervical, mesial and apical thirds. After the root canal preparation, the roots were decalcified, cut to 6 μm thickness, from the cervical third to the apical one and dyed with hematoxylin-eosin. The roots were then analysed as to irregularities in the dentine wall of the root canal, and presence of any residue. The variance method (ANOVA) was used to statistically evaluate the results, which presented statistically relevant difference amongst the groups. ProTaper removed dentine more significantly than Mtwo and K3 (p<0,05). Mtwo removed more than K3 (p<0,05). All groups presented significant increase in the area of the root canal after preparation (p<0,05), mainly in the cervical third and the apical third. Cervical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3, and in the apical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3 (p<0,05). Protaper, Mtwo e K3 significantly increased the mesial-distal distance... (Complete abstract click electronic access below) / Doutor
15

Tomografia computadorizada de feixe cônico para avaliação do tratamento da classe II divisão 1ª com o aparelho Herbst no espaço aéreo faríngeo /

Palomino-Gómez, Sandra Patricia. January 2010 (has links)
Orientador: Dirceu Barnabé Raveli / Banca: Gladys Cristina Dominguez Rodriguez / Banca: Ary dos Santos-Pinto / Resumo: As mudanças nos padrões de respiração nasal afetam profundamente o crescimento craniofacial. Avanços tecnológicos, como a tomografia computadorizada de feixe cônico (TCFC), têm sido utilizados com o propósito de se observar tridimensionalmente, o crânio, a face e o espaço aéreo faríngeo, sendo possível a avaliação das mudanças do espaço aéreo induzidas pelos aparelhos ortopédicos propulsores mandibular. O intuito deste estudo é apresentar um método de avaliação das vias aéreas de fácil reprodutibilidade, e avaliar, mediante a TCFC, os efeitos do aparelho de Herbst bandado no espaço aéreo orofaríngeo (EAOF), nasofaríngeo (EANF) e faríngeo superior (EAFS), em indivíduos com má oclusão classe II divisão 1ª. A amostra foi composta por imagens digitais de 15 indivíduos (idade média inicial de 15,7 anos ± 1.7, após surto de crescimento pubertário) com má oclusão classe II divisão 1ª, tratados com aparelho Herbst bandado (8 meses). Os exames tomográficos foram realizados antes (T1) e após (T2) o tratamento. A fase inicial foi realizada com a orientação do nos planos; axial, coronal e sagital. Foram mensurados: comprimento no software Dolphin 3D ®: comprimento, maior área no corte coronal, maior área no corte sagital, área mínima da secção transversal e volume, de EANF, EAOR e EAFS (orofaringe e nasofaringe). Dois avaliadores previamente calibrados mensuraram duas vezes apenas um tempo das tomografias, para observar a reprodutibilidade (inter-examinador) e replicabilidade (intra-examinador). Sendo confirmada a reprodutibilidade do método, foi avaliado o efeito do aparelho Herbst, analisando os períodos pré (T1) e pós (T2) tratamento ortopédico. A análise estatística dos dados foi realizada em duas etapas. Primeira etapa, a confiabilidade das medidas apresentaram boa replicabilidade (intra-examinador)... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Changes in nasal breathing patterns profoundly affects the craniofacial growth. Technological advances, such as cone beam computed tomography (CBCT), have been used in order to observe three-dimensionally: the skull, face and pharyngeal airway space, with possible assessment of airspace changes induced by orthopedic activators. The purposes of this study are to present a method for assessing airway that is easily reproducted, and evaluate through the CBCT the effects of banded Herbst appliance in the oropharyngeal airspace (EAOF), nasopharyngeal (EANF) and upper pharynx (EAFS) in individuals with malocclusion class II division 1. The sample consisted of digital images of 15 individuals (initial age of 15.7 years ± 1.7, after pubertal growth spurt) with malocclusion class II division 1, treated with banded Herbst appliance (8 months). CBCT scans were performed before (T1) and after (T2) treatment. The initial phase was conducted with the guidance of planes: axial, coronal and sagittal. The following were measured: the largest area in the coronal and sagittal, minimum cross-sectional area and volume of EANF, and EAOR EAFS (oropharynx and nasopharynx) by length in Dolphin 3D® software. Two calibrated evaluator mesured twice time of CBCT to observe the reproducibility (inter-examiner) and repeatability (intra-examiner). Once the reproductability of the method was coinfirmed, the effect of the Herbst applicance was evaluated before (T1) and after (T2) the orthodontic treatment. The statistical analysis was performed in two steps. First step, the reliability of the measurements showed good repeatability (intra-examiner) (ICC ≥ 0.984) and good reproducibility (inter-examiner) (ICC ≥ 0.911) for all measures except the minimum area of cross section of all regions, which showed variability. Second step, once confirmed the reliability of the measuremens, Student t test was appleid, significance... (Complete abstract click electronic access below) / Mestre
16

Dacriocistografia em cães com o emprego da ressonância magnética (DCG-RM) e da tomografia computadorizada (DCG-TC) /

Rached, Paula Abi. January 2009 (has links)
Resumo: A dacriocistografia convencional (DCG) é a técnica de imagem mais utilizada para a avaliação do sistema lacrimal excretor. Recentemente, DCG por ressonância magnética (DCG-RM) e por tomografia computadorizada (DCG-TC) têm sido empregadas em pacientes humanos. No entanto, em cães, os relatos de investigações sobre estas técnicas são escassos. Os objetivos, com este estudo, foram: o desenvolvimento de protocolos de RM e TC; a comparação destas técnicas para avaliação do sistema lacrimal excretar; a avaliação biométrica do ducto nasolacrimal e a apresentação da utilidade de ferramentas de reconstrução tridimensional para a visibilização do sistema lacrimal excretor em cães. Material e Métodos: DCG-RM e DCG-CT foram realizadas bilateralmente em 32 cadáveres de cães. Após canulado, o canalículo superior foi preenchido com meio de contraste (contraste iodado puro e gadolinio 1:200, para CT e RM respectivamente). Imagens transversais e tridimensionais de TC foram obtidas utilizando-se cortes de 0,8mm e 2mm de espessura. O protocolo de RM incluiu as sequências T1W/3D/FFE, T1WfTSE e PDW/TSE. Em ambas as técnicas, foram testadas as orientações perpendicular e obliqua dos cortes. Os diâmetros transversais e longitidinais e o comprimento dos ductos nasolacrimais de 23 cães foram mensurados bilateralmente. Resultados: no exame de DCG-TC, todos os componentes foram visibilizados de modo satisfatório na grande maioria dos animais. O exame de DCG-RM apresentou tempo de varredura mais longo, obtendo-se melhores resultados com a seqüência T1W/3D/FFE. As médias dos diâmetros transversais para os grupos de peso corporal 1, 2 e 3 nas três regiões avaliadas variaram entre 1,07mm e 1,09mm. As médias dos diâmetros longitudinais para as classes 1, 2 e 3 nas três regiões... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Conventional radiographic cannulation dacryocystography is the most commonly used technique for evaluallon of the nasolacrimal system. Recently, MR-DCG and CT¬DCG have been extensively employed in humans patients. Systemafic investigations of these techniques in dogs are not frequently observed in medicai literature. The objectives of this study are: 1, development of MR-DCG and CT-DCG protocols and the comparison between these techniques for the evaluation of the nasolacrimal system in dogs and 2, biometric evaluation of the nasolacrimal duct and to test the usefulness of 3D reconstruction techniques for visualization of this system in dogs. Material and Methods: MR-DCG and CT-DCG were bilaterally performed in 32 cadavers of dogs. The superior lacrimal canaliculi was canulated and contrast media injected (Imerone and Omniscan® 1:200, for CT and MR respectively). CT transverse and 3D images were obtained using 0.8 to 2mm-thick slices. MR protocol included transverse images obtained by T1W/3D/FFE, T1WfTSE and PDW/TSE sequences. For both techniques, two sfice orientations were tested: perpendicular and oblique to the hard palate. Transverse and longitudinal diameters and total length of the nasolacrimal ducts of 23 dogs were bilaterally obtained. Results: in CT scans, ali the structures could be well visualized in great majority of the dogs. MR images required longer scan time. Sequence T1W/3D/FFE offered beber results when compared to PDWTTSE and T1WTTSE. The mean longitudinal diameter of the nasolacrimal duct in weight classes 1, 2 and 3 in ali regions ranged between 1,07mm e 1,09mm. The mean transversal diameter of the nasolacrimal duct in weight classes 1, 2 and 3 in ali regions ranged between 1,34mm e 3,31 mm. The mean length of the nasolacrimal duct in weight classes 1, 2 and 3 were respecfively 70mm, 93,55mm... (Complete abstract click electronic access below) / Orientador: Julio Carlos Canola / Coorientador: Eberhard Ludewig / Banca: Naida Cristina Borges / Banca: Fernando De Biasi / Banca: Marcia Rita Fernandes Machado / Banca: José Luiz Laus / Doutor
17

Métodos não convencionais para avaliação da porosidade e da densidade do solo de um latossolo vermelho /

Encide, Ana Paula, 1978- January 2005 (has links)
Orientador: Maria Helena Moraes / Banca: Katia Luciene Maltoni / Banca: Maria de Fátima Guimarães / Resumo: O objetivo deste trabalho foi comparar dois métodos de análise para densidade do solo (anel volumétrico e tomografia computadorizada) e dois métodos para porosidade (mesa de tensão e análise de imagens de blocos) em um LATOSSOLO VERMELHO. A pesquisa foi conduzida na Fazenda Experimental Lageado-FCA/UNESP, Botucatu-SP. O delineamento experimental foi o de blocos casualizados com 4 repetições. Com exceção das imagens de blocos os demais dados foram submetidos ao teste F para análise de variância e ao teste de Tukey para a comparação de médias a 5% de probabilidade. As amostras foram coletadas na profundidade de 0-0,20 m em semeadura direta, sistema de preparo convencional e parcela com vegetação natural. A densidade do solo determinada pelo método do anel volumétrico apresentou diferenças para os sistemas de semeadura direta e preparo convencional e o sistema mata, para as camadas de 0-0,05; 0,05-0,10 e 0,10- 0,15 m. O método da tomografia computadorizada apresentou diferença para densidade do solo entre os sistemas de preparo convencional e vegetação natural e a semeadura direta, para a camada de 0-0,20 m. O método do anel volumétrico superestimou os valores de densidade, nas camadas de 0-0,05 e 0,05-0,10 m, comparado com o método da tomografia computadorizada, cujos resultados foram coerentes como os de resistência à penetração. O coeficiente de variação relativo aos valores de densidade do solo foram menores para o método da tomografia computadorizada em comparação com o método do anel volumétrico. O método da mesa de tensão não apresentou diferenças significativas para macroporosidade para os sistemas de manejo. O método de análise de imagens evidenciou diferenças entre a semeadura direta e vegetação natural e preparo convencional. / Abstract: The objective of this research was to compare two methods for soil density (core sampling and computed tomography) and two methods for porosity (tension column and blocks image analysis) measured in a red latosol (Orthox). The experiment was carried out in Lageado Experimental Farm, FCA/UNESP in Botucatu city, State of São Paulo in a randomized block design with four replicates. With exception of the blocks image analysis, data were submitted to test F for variance analysis and Tukey test for the means comparison with 5% of probability. The samples were collected in layers of 0-0.20m of profundity under no tillage, conventional tillage and natural vegetation systems. Core sampling method resulted in difference in the soil density among the systems of no tillage, conventional tillage and natural vegetation for the layers of 0-0.05; 0.05-0.10 and 0.10-0.15m. The computed tomography method showed difference in the soil density between conventional tillage, natural vegetation and no tillage system for the layer of 0-0.20m. The core sampling method overestimated the values of soil density, in the layers of 0-0.05 and 0.05-0.10m, considering that the results obtained through computed tomography method whose results were coherent with the soil penetration resistance ones. The variation coefficient related to the values of soil density was smaller for the method of the computed tomography related to the core sampling method. Tension table method didn't result in macro porosity difference among the tillage systems. Blocks image analysis method evidenced difference among the systems of no tillage, natural vegetation and conventional tillage. / Mestre

Page generated in 0.0638 seconds