• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • Tagged with
  • 18
  • 18
  • 18
  • 18
  • 18
  • 16
  • 15
  • 13
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação das características tomográficas de ameloblastoma e tumor odontogênico queratocístico.

Ribeiro, Leila Brito de Queiroz 19 October 2015 (has links)
Submitted by ROBERTO PAULO CORREIA DE ARAÚJO (ppgorgsistem@ufba.br) on 2016-08-30T16:57:39Z No. of bitstreams: 1 Leila Brito. de Q. Ribeiro -tese.pdf: 1353246 bytes, checksum: 70df80cf3c119c195b3bda85102ef637 (MD5) / Made available in DSpace on 2016-08-30T16:57:39Z (GMT). No. of bitstreams: 1 Leila Brito. de Q. Ribeiro -tese.pdf: 1353246 bytes, checksum: 70df80cf3c119c195b3bda85102ef637 (MD5) / O ameloblastoma e o tumor odontogênico queratocístico são neoplasias benignas que se desenvolvem a partir de remanescentes epiteliais de estruturas envolvidas no desenvolvimento dentário. O diagnóstico imaginológico desses tumores é limitado, quando se utiliza métodos radiográficos convencionais. A tomografia computadorizada multislice é uma ferramenta de escolha para o diagnóstico de lesões, uma vez que permite a visualização de tecidos moles e duros, a relação da lesão com as estruturas adjacentes, além de possibilitar a mensuração da lesão e a obtenção do coeficiente de atenuação, que representa a densidade do tecido. O presente estudo tem por objetivo a comparação do coeficiente de atenuação, coeficiente de variação, características ósseas: corticalização das margens, perfuração e expansão de corticais; e características dentárias: reabsorção radicular, deslocamento dentário e associação com dentes não irrompidos, além de análise dimensional desses tumores. As lesões foram divididas em quatro subtipos: ameloblastoma sólido/multicístico, ameloblastoma unicístico, tumor odontogênico queratocístico solitário e tumor odontogênico queratocístico múltiplo. Os coeficientes de atenuação dos tumores foram obtidos pela utilização do programa Osirix, a partir da delimitação da maior área tumoral em cortes axiais. Foram calculadas as médias do coeficiente de atenuação e do coeficiente de variação. As alterações ósseas e dentárias e as mensurações foram obtidas a partir de cortes multiplanares. As médias dos coeficientes de atenuação foram 34,05±12,65 (ASM), 27,29±12,65 (AU), 24,59±6,79 (TOQs) e 51,76±15,92 (TOQm). A diferença entre os coeficientes de atenuação entre os TOQs e TOQm foram estatisticamente significantes (p<0,05). O coeficiente de variação foi de 94,48±52,02 (ASM), 99,52±63,02 (AU), 115,35±97,98 (TOQs) e 41,70±13,20 (TOQm). A diferença entre os coeficientes de variação entre TOQs e TOQm foi estatisticamente significante. A perfuração óssea e a reabsorção radicular foram mais frequentes em AM do que em TOQ (p<0,05). Os AM e TOQ apresentam crescimento maior no sentido mésio-distal que vestíbulo-lingual ou crânio-caudal. O volume médio das lesões de AM (76,34m3) foi maior que o volume médio dos TOQ (11,51m3) (p<0,05). A relação entre menor volume e maior média de UH foi estatisticamente significante para os AM. A TC do tipo multislice demonstrou ser uma ferramenta útil para obtenção, análise e comparação dos coeficientes de atenuação e variação, assim como para as características imaginológicas que podem auxiliar no diagnóstico de ameloblastoma e do tumor odontogênico.
2

Análise tomográfica do canal palatino e da região pterigomaxilar aplicada à ostetomia Le Fort I

Oliveira, Gabriel Queiroz Vasconcelos January 2016 (has links)
Submitted by Hiolanda Rêgo (hiolandarego@gmail.com) on 2017-03-14T15:22:52Z No. of bitstreams: 1 Dissertação_ODONTO_ Gabriel Queiroz Vasconcelos Oliveira.pdf: 1044806 bytes, checksum: 52077a754319496337819c2305bbd9d0 (MD5) / Approved for entry into archive by Delba Rosa (delba@ufba.br) on 2017-06-07T13:22:27Z (GMT) No. of bitstreams: 1 Dissertação_ODONTO_ Gabriel Queiroz Vasconcelos Oliveira.pdf: 1044806 bytes, checksum: 52077a754319496337819c2305bbd9d0 (MD5) / Made available in DSpace on 2017-06-07T13:22:27Z (GMT). No. of bitstreams: 1 Dissertação_ODONTO_ Gabriel Queiroz Vasconcelos Oliveira.pdf: 1044806 bytes, checksum: 52077a754319496337819c2305bbd9d0 (MD5) / Os exames tomográficos e a possibilidade do planejamento cirúrgico virtual possibilitaram um aumento de informações que contribuem para a avaliação pré-operatória. A instrumentação da região posterior da maxila na osteotomia Le Fort I possui a peculiaridade da difícil visualização da região pterigomaxilar, que se apresenta próxima a artéria palatina descendente. O conhecimento da anatomia e de sua relação com a técnica cirúrgica é imprescindível para a maior segurança da osteotomia Le Fort I. O objetivo do presente estudo foi determinar as medidas anatômicas lineares referentes ao canal palatino e fissura pterigomaxilar associadas à osteotomia Le Fort I. A amostra foi composta por 75 imagens de pacientes (150 lados) que foram submetidos ao exame por tomografia computadorizada multislice na avaliação pré-cirúrgica. As imagens foram categorizadas de acordo com o gênero, lado, classe esquelética e perfil facial de cada paciente. O comprimento anterior da abertura piriforme ao canal palatino foi maior para o gênero masculino (p=0,0121), e além disso observou-se que havia diferença entre os lados, sendo o lado direito maior no gênero masculino (p=0,0397) e para o gênero feminino o lado esquerdo apresentou maior tamanho (p=0,0297). O comprimento posterior do canal palatino à fissura pterigomaxilar foi maior para o gênero feminino (p=0,0295). A espessura óssea da região pterigomaxilar apresentou maiores médias associadas à classe I, havendo diferença estatística entre a classe I e III (p=0,0371) e II e III (p=0,0094). Para o grupo de braquicéfalos, o gênero feminino apresentou-se maior que o masculino, para a medida da espessura posterior da maxila (p=0,0078). O grupo de mesocéfalos apresentou uma maior medida para a espessura posterior da maxila nas imagens do gênero feminino (p=0,0015). Pode-se concluir que o gênero, classe esquelética e padrão facial são parâmetros que influenciam na anatomia da região pterigomaxilar e do canal palatino, devendo ser consideradas durante a avaliação pré-operatória.
3

Análise tomográfica Cone Beam e histológica do preparo do canal radicular com três sistemas rotatórios /

Moraes, Sergio Herrero. January 2010 (has links)
Orientador: Marcelo Gonçalves / Banca: Yara Teresinha Correa Silva Sousa / Banca: Ivaldo Gomes de Moraes / Banca: Fábio Luiz Camargo Villela Berbert / Banca: Mario Tanomaru Filho / Resumo: O presente estudo teve como objetivos as análise tomográfica e histológica do preparo do canal radicular com três sistemas rotatórios de NiTi: ProTaper (grupo 1), Mtwo (grupo 2) e K3 (grupo 3). Trinta e seis molares superiores foram radiografados pela técnica de tomografia cone beam (feixe cônico) antes e depois do preparo rotatório do canal mésio-vestibular. Os dentes foram pesados antes e depois do preparo para analisar a capacidade de corte dos instrumentos pela remoção de dentina. Aumento na área do canal, no alargamento do comprimento mésio-distal do canal, centralização e transporte do canal nos terços cervical, médio e apical foram analisadas nas tomografias computadorizadas transferidas para o software Canvas 11. Após o preparo dos canais radiculares as raízes foram descalcificadas, cortadas com 6 μm de espessura e coradas com hematoxilina-eosina, para exame das irregularidades das paredes de dentina do canal radicular e da presença de resíduos no canal. Para avaliar estatisticamente os resultados foi utilizado o método de variância (ANOVA).Os resultados revelaram que houve diferença estatisticamente significante entre os grupos. ProTaper removeu significativamente mais dentina do que Mtwo e K3 (p<0,05). Mtwo removeu mais do que o K3 (p<0,05). Protaper, Mtwo e K3 aumentaram significativamente a área do canal depois do preparo (p<0,05). A diferença foi significativa no terço cervical entre ProTaper e K3 (p<0,05), Mtwo e K3; terço médio entre ProTaper e K3 (p<,0,05), Mtwo e K3 (p<0,05); no terço apical entre ProTaper e K3 (p<0,05), Mtwo e K3.p<0,05). Protaper, Mtwo e K3 aumentaram significativamente o comprimento mésio-distal do canal. A diferença foi significativa entre ProTaper e K3 (p<0,05) , Mtwo e K3 nos terços cervical, médio e apical. Na avaliação da centralização do canal foi encontrada diferença significativa de desvio entre os grupos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The key goal of the present study was the histological and tomographic analysis of the root canal preparation with three NiTi rotatory systems: ProTaper (group 1), Mtwo (group 2) e K3 (group 3). Thirty six maxillary molar teeth were radiographed with the cone beam technique before and after the mesial-buccal root canal preparation. The teeth were weighted before and after preparation to analyse dentine removal capacity of the cutting instruments. Images from computed tomography were transferred to the software Canvas 11 to allow for analysis of the increase of the root canal area, the widening of the mesial-distal distance, and the root canal centring and transport in the cervical, mesial and apical thirds. After the root canal preparation, the roots were decalcified, cut to 6 μm thickness, from the cervical third to the apical one and dyed with hematoxylin-eosin. The roots were then analysed as to irregularities in the dentine wall of the root canal, and presence of any residue. The variance method (ANOVA) was used to statistically evaluate the results, which presented statistically relevant difference amongst the groups. ProTaper removed dentine more significantly than Mtwo and K3 (p<0,05). Mtwo removed more than K3 (p<0,05). All groups presented significant increase in the area of the root canal after preparation (p<0,05), mainly in the cervical third and the apical third. Cervical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3, and in the apical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3 (p<0,05). Protaper, Mtwo e K3 significantly increased the mesial-distal distance... (Complete abstract click electronic access below) / Doutor
4

Análise tomográfica Cone Beam e histológica do preparo do canal radicular com três sistemas rotatórios

Moraes, Sergio Herrero [UNESP] 27 September 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-09-27Bitstream added on 2014-06-13T19:20:40Z : No. of bitstreams: 1 moraes_sh_dr_arafo.pdf: 695564 bytes, checksum: 9ac4357d57946680feb71b26574a149e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / O presente estudo teve como objetivos as análise tomográfica e histológica do preparo do canal radicular com três sistemas rotatórios de NiTi: ProTaper (grupo 1), Mtwo (grupo 2) e K3 (grupo 3). Trinta e seis molares superiores foram radiografados pela técnica de tomografia cone beam (feixe cônico) antes e depois do preparo rotatório do canal mésio-vestibular. Os dentes foram pesados antes e depois do preparo para analisar a capacidade de corte dos instrumentos pela remoção de dentina. Aumento na área do canal, no alargamento do comprimento mésio-distal do canal, centralização e transporte do canal nos terços cervical, médio e apical foram analisadas nas tomografias computadorizadas transferidas para o software Canvas 11. Após o preparo dos canais radiculares as raízes foram descalcificadas, cortadas com 6 μm de espessura e coradas com hematoxilina-eosina, para exame das irregularidades das paredes de dentina do canal radicular e da presença de resíduos no canal. Para avaliar estatisticamente os resultados foi utilizado o método de variância (ANOVA).Os resultados revelaram que houve diferença estatisticamente significante entre os grupos. ProTaper removeu significativamente mais dentina do que Mtwo e K3 (p<0,05). Mtwo removeu mais do que o K3 (p<0,05). Protaper, Mtwo e K3 aumentaram significativamente a área do canal depois do preparo (p<0,05). A diferença foi significativa no terço cervical entre ProTaper e K3 (p<0,05), Mtwo e K3; terço médio entre ProTaper e K3 (p<,0,05), Mtwo e K3 (p<0,05); no terço apical entre ProTaper e K3 (p<0,05), Mtwo e K3.p<0,05). Protaper, Mtwo e K3 aumentaram significativamente o comprimento mésio-distal do canal. A diferença foi significativa entre ProTaper e K3 (p<0,05) , Mtwo e K3 nos terços cervical, médio e apical. Na avaliação da centralização do canal foi encontrada diferença significativa de desvio entre os grupos... / The key goal of the present study was the histological and tomographic analysis of the root canal preparation with three NiTi rotatory systems: ProTaper (group 1), Mtwo (group 2) e K3 (group 3). Thirty six maxillary molar teeth were radiographed with the cone beam technique before and after the mesial-buccal root canal preparation. The teeth were weighted before and after preparation to analyse dentine removal capacity of the cutting instruments. Images from computed tomography were transferred to the software Canvas 11 to allow for analysis of the increase of the root canal area, the widening of the mesial-distal distance, and the root canal centring and transport in the cervical, mesial and apical thirds. After the root canal preparation, the roots were decalcified, cut to 6 μm thickness, from the cervical third to the apical one and dyed with hematoxylin-eosin. The roots were then analysed as to irregularities in the dentine wall of the root canal, and presence of any residue. The variance method (ANOVA) was used to statistically evaluate the results, which presented statistically relevant difference amongst the groups. ProTaper removed dentine more significantly than Mtwo and K3 (p<0,05). Mtwo removed more than K3 (p<0,05). All groups presented significant increase in the area of the root canal after preparation (p<0,05), mainly in the cervical third and the apical third. Cervical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3, and in the apical third the difference was ProTaper and K3 (p<0,05), Mtwo and K3 (p<0,05). Protaper, Mtwo e K3 significantly increased the mesial-distal distance... (Complete abstract click electronic access below)
5

Avaliação da frequência de nódulos hepáticos em pacientes submetidos ao procedimento de Fontan: o papel da ultrassonografia, tomografia computadorizada e ressonância magnética / Evaluation of frequency of hepatic nodules in patients after Fontan procedure: role of ultrasound, computed tomography and magnetic resonance imaging

Horvat, Natally de Souza Maciel Rocha 29 March 2019 (has links)
Introdução: Pacientes com cardiopatia congênita submetidos ao procedimento de Fontan (PF) vêm atingindo a idade adulta com significativas consequências sistêmicas, particularmente hepáticas. Tais injúrias hepáticas podem resultar em fibrose, cirrose e nódulos hepáticos (NH), que podem ser benignos ou malignos. Porém, não há, até o momento, consenso na literatura quanto ao rastreamento desses nódulos, sobretudo acerca do início e da melhor modalidade para tal fim. Objetivo: Esse estudo objetivou (a) avaliar a frequência de NH em pacientes submetidos ao PF na ultrassonografia (USG), tomografia computadorizada (TC) e ressonância magnética (RM), assim como a concordância entre tais métodos; (b) investigar se há correlação entre a presença de NH e algumas variáveis clínicas e laboratoriais; (c) analisar se há diferença nos valores de rigidez hepática utilizando a elastografia por USG por meio da técnica acoustic radiation force impulse (ARFI) entre os pacientes com e sem NH. Métodos: Foram recrutados, prospectivamente, 49 pacientes submetidos ao PF entre agosto de 2014 e junho de 2016. Esses pacientes foram submetidos a rastreamento clínico e laboratorial de hepatopatia, e elastografia hepática por USG com ARFI, TC e RM. A concordância entre os testes foi acessada utilizando o kappa de Cohen. A correlação entre NH com as outras variáveis foi realizada com teste t de Student ou teste de Mann-Whitney para variáveis contínuas sem distribuição normal e teste qui-quadrado ou teste de Fisher para variáveis categóricas. Resultados: NH foram detectados em 3/49 (6%), 14/44 (31,8%) e 19/48 (39,6%) pacientes na USG, TC e RM, respectivamente. Houve uma concordância quase perfeita entre TC e RM na detecção de NH (kappa: 0,849, p < 0,001), porém a USG não demonstrou concordância com TC e RM (kappa: 0,006, p=0,095 e kappa: 0,083, p = 0,032, respectivamente). Nenhuma variável clínica ou laboratorial apresentou correlação significativa com a presença de NH, inclusive o tempo após o PF. Os valores de rigidez hepática no ARFI foram significativamente mais elevados nos pacientes com NH (2,64 ± 0,81 m/s vs. 1,94 ± 0,49 m/s; p=0,002) e foram um preditor significativo para NH (AUC: 0,767, p=0,002). Conclusão: Na nossa população, mais de um terço dos pacientes após o PF apresentou NH na TC ou RM, mas a USG não detectou a grande maioria dos nódulos. Nenhum dado clínico ou laboratorial apresentou correlação significativa com a presença de NH. A rigidez hepática no ARFI foi significativamente mais elevada nos pacientes com NH. Tais achados sugerem que a USG não é um método diagnóstico efetivo no rastreamento de NH, porém a elastografia por ARFI pode ser útil, orientando quais pacientes devem submetidos à TC ou RM / Background: Patients with congenital heart disease after Fontan procedure (FP) are reaching the adulthood with significant systemic consequences, particularly to the liver. Those hepatic injuries can cause liver fibrosis, cirrhosis and hepatic nodules (HN), which can be benign or malignant. Currently, there is no consensus in the literature regarding screening of HN in patients after FP concerning when to start and which is the best imaging modality indicated for it. Purpose: This study aimed (a) to evaluate the frequency of HN in patients after FP on ultrasound (US), computed tomography (CT) and magnetic resonance imaging (MRI), as well as their inter-test agreement; (b) to investigate if there is any correlation between presence of HN and clinical or laboratorial variables; (c) to analyze if liver stiffness (LS) values using acoustic radiation force impulse (ARFI) on US elastography differ between patients with and without HN. Methods: We prospectively recruited 49 patients after FP from August 2014 to June 2016. These patients underwent clinical and laboratorial screening of hepatic disorders, ARFI elastography of the liver, abdominal US, CT and MRI. Intertest agreement was assessed by using weighted Cohen\'s kappa as statistics. The dependence of HN with the variables was performed using Student\'s t test or ANOVA for independent continuous variables without normal distribution; and chi-square test or Fisher\'s test for categorical variables. Results: HN were detected in 3/49 (6%), 14/44 (31.8%), and 19/48 (39.6%) patients on US, CT and MRI, respectively. There was an almost perfect agreement between CT and MRI in detecting HN (kappa: 0.849, p < 0.001); however, US had a non-significant correlation with CT and MRI (kappa: 0.006, p=0.095 and kappa: 0.083, p = 0.032, respectively). No clinical or laboratorial data had any significant correlation with the presence of HN, including time since FP. LS on ARFI was significantly higher in patients with HN (2.64 ± 0.81 m/s vs. 1.94 ± 0.49 m/s; p=0.002) and was a significant predictor of HN (AUC 0.767, p=0.002). Conclusion: In our study, more than one-third of patients after FP had HN on CT or MRI, but US did not detect the vast majority of them. No clinical or laboratorial data had any significant correlation with the presence of HN. LS on ARFI was significantly higher in patients with HN. These findings may suggest that US is not an effective imaging modality for screening of HN; however, ARFI elastography may help guiding which patients should be further imaged with CT or MRI
6

O valor da ultra-sonografia na avaliação do traumatismo abdominal fechado / Value of ultrasound in the evaluation of blunt abdominal trauma

Jayanthi, Shri Krishna 13 March 2008 (has links)
O trauma é uma das principais causas de morbidade e mortalidade em uma faixa etária que compreende adolescentes e adultos jovens, em proporção dominante do sexo masculino, com grande impacto econômico e social. Dentro do complexo do trauma, o traumatismo abdominal fechado (TAF) é um evento bastante freqüente e apresenta dificuldade na avaliação e manejo, uma vez que o exame clínico apresenta baixa sensibilidade e especificidade. A detecção de hemoperitônio é um dos métodos de avaliação indireta de possíveis lesões intra-abdominais, inicialmente pela punção abdominal diagnóstica e posteriormente pela lavagem peritoneal diagnóstica, que, apesar da eficácia, apresentam inconvenientes invasividade e impossibilidade na quantificação do hemoperitônio e no estadiamento da lesão, resultando em laparotomias não-terapêuticas. Os métodos de imagem prestam utilidade na investigação de lesões intra-abdominais, como a radiografia convencional e contrastada, ultra-sonografia (US) e a tomografia computadorizada (TC), esta última o método que apresenta melhor resolutividade, porém como desvantagens o custo, acessibilidade, o uso de radiação ionizante e meio de contraste e o deslocamento do paciente até o aparelho. A US apresenta-se como alternativa na avaliação inicial destes pacientes como método não invasivo e com potencial de dano virtualmente ausente, de baixo custo, de rápida realização e portátil. Apesar disso, este método também apresenta suas limitações, como na de lesões intra-abdominais na ausência de líquido livre. Este estudo foi realizado com a finalidade de estabelecer o desempenho da US neste contexto, permitindo racionalizar o uso da TC. Com essa finalidade foram estudados 163 pacientes atendidos pelo PS-HC/FMUSP, com a realização consecutiva de US e TC. A população estudada enquadra-se no perfil usual das vítimas de trauma, sendo 83% do sexo masculino e 56% na faixa etária entre 20 e 39 anos e em 73% dos casos eram vítimas de acidentes de trânsito. Eles foram trazidos ao serviço num tempo médio de 51 minutos, na maior parte estáveis e com nível de consciência satisfatório. A US levou em média 5 minutos para ser realizada e o intervalo médio até a realização da TC foi de155 minutos. Dos 163 pacientes 31 (19%) apresentaram US positiva e 132 (81%) apresentaram US negativa. Dos mesmos 163 pacientes 33 (20,2%) apresentaram TC positiva e 130 (79,8%) apresentaram TC negativa, resultando em sensibilidade de 73%, especificidade de 95%, acurácia de 90% em prevalência de 20%, com valor preditivo positivo de 77% e valor preditivo negativo de 93%. Corrigindo quanto à detecção de líquido livre, resulta-se em sensibilidade de 64%, especificidade de 98%, acurácia de 89% em prevalência de 27,6% e valor preditivo positivo de 93% e valor preditivo negativo de 88%. Ao se considerar a evolução dos pacientes, o desempenho da US foi semelhante ao da TC. Ao se considerar a necessidade de cirurgia a US apresentou acurácia de 87%, com valor preditivo positivo de 58% e valor preditivo negativo de 94%, próximo da TC, com 91% de acurácia, 67% de valor preditivo positivo e 97% de valor preditivo negativo. 24% dos pacientes com lesões intra-abdominais não apresentavam líquido livre, registrados pela TC. O espaço hepatorrenal e a pelve são os locais mais freqüentes do encontro de líquido, sendo 74% e 67% à US e 51% e 62% à TC, respectivamente. Entre os fatores que indicaram tendência de necessidade cirúrgica destaca-se a presença de líquido no espaço hepatorrenal (14 de 20 pacientes) e somatória dos bolsões de líquido acima de 3,0 cm. A detecção de lesões em víscera parenquimatosa foi baixa: 4 casos em 33, sendo que apenas 2 deles se confirmaram. Dentre os fatores que limitam o estudo pela US estão as lesões intraparenquimatosas que não se associam a líquido livre e hematomas retroperitoneais. A experiência do examinador não influenciou no número de casos positivos ou negativos, mas notou-se uma tendência a falso-positivos em examinadores mais experientes e falso-negativos em menos experientes. Assim, a US apresenta-se como ferramenta útil na avaliação inicial de traumatismo abdominal fechado, fornecendo subsídios para avaliação clínica, que associado aos demais dados, permite determinar a conduta. / Trauma is a major cause of morbidity and mortality in an age group including from teenagers to young adults, in a male dominat proportion, resulting in great economic and social impact. Within the complex of trauma, blunt abdominal trauma (BAT) is frequent event and presents difficulty in the evaluation and management since the clinical examination shows low sensitivity and specificity. The detection of hemoperitoneum is one of the methods of evaluation of possible indirect intra-abdominal injuries, initially using direct diagnostic abdominal paracentesis and posteriorly the diagnostic peritoneal lavage, that despite the effectiveness, have drawbacks such as invasiveness and the inability of hemoperitoneum quantification and the lesion staging, resulting in non-therapeutic laparotomies. Imaging methods provide useful information in the investigation of abdominal injuries, such as conventional and contrast radiology, ultrasound (US) and computed tomography (CT), which is the best effective method, but has its own drawbacks, such as cost, accessibility, use of ionizing radiation and contrast media and the displacement of the patient to the machine. US presents itself as an alternative in the initial evaluation of these patients as noninvasive method, with lack of harmfulness, low cost, fast answer and portability. Nevertheless, this method also has its limitations, as in cases of abdominal injuries without free fluid. This study was conducted in order to establish the performance of the US in this setting, allowing to rationalise the use of CT. For this purpose we studied 163 patients treated in the ER of HC/FMUSP, with the completion of consecutive US and CT. The population fits the usual profile of trauma victims, with 83% male, 56% in the age group between 20 and 39 years and in 73% of cases victims of traffic accidents. They were brought to the service in an average time of 51 minutes, mainly stable and with satisfactory level of consciousness. US took on average 5 minutes to be performed and the average interval until CT completion was 155 minutes. 31 (19%) of 163 patients showed positive US and 132 (81%) had negative US. 33 (20.2%) of the same 163 patients had positive CT and 130 (79.8%) had negative CT, resulting in a sensitivity of 73%, specificity of 95%, accuracy of 90% in 20% prevalence, with 77% of positive predictive value and 93% of negative predictive value. Correcting the detection of free fluid, results in 64% of sensitivity 98% of specificity 89% of accuracy in 28% of prevalence, with 93% of positive predictive value and 88% of negative predictive value of 88%. Considering the evolution of the patients, US performance was similar to that of CT. Considering need for surgery the US presented accuracy of 87%, positive predictive value of 58% and negative predictive value of 94%, near CT, with accuracy of 91%, predictive value of 67% and negative predictive value of 97%. 24% of patients with abdominal injuries did not have free fluid, as recorded by CT. The hepatorrenal space and pelvis were the most frequent sites fluid finding, 74% and 67% at US and 51% and 62% at CT, respectively. Among the factors that showed a tendency for surgery requirement were the presence of fluid in hepatorrenal space (14 of 20 patients) and the sum of liquid pockets over 3.0 cm. Detection of parenchymal lesions was low: 4 cases in 33, while only 2 of them confirmed. Among the factors that limit the US study are parenchymal lesions not associated with free fluid and retroperitoneal hematomas. Examiner experience did not influence the number of negative or positive cases, but there was a tendency to false positive with most experienced examiners and false negative with less experienced. Thus, US is an useful tool in the initial evaluation of blunt abdominal trauma, providing information for clinical evaluation, which associated with other data, tailors the management.
7

Sensibilidade e especificidade dos métodos de diagnóstico por imagem (ultrassonografia, ressonância magnética e tomografia computadorizada) na detecção de nódulos hepáticos no cirrótico com correlação histológica do explante / Sensitivity and specificity of imaging diagnostic methods (ultrasonography, magnetic resonanceand computed tomography) in the detection of liver nodules in cirrhotic patients, with histological correlation of the explanted liver

Carmen Silvia Cerqueira do Val Fausto 13 December 2011 (has links)
INTRODUÇÃO: Os equipamentos dos métodos diagnósticos por imagem estão em constante e rápido desenvolvimento tecnológico, o que tem levado ao aprimoramento da detecção dos nódulos de carcinoma hepatocelular em pacientes cirróticos. OBJETIVO: Comparar prospectivamente a sensibilidade e a especificidade dos diferentes métodos diagnósticos de imagem na detecção de nódulos hepáticos em pacientes cirróticos com os explantes hepáticos. MÉTODOS: Vinte pacientes aguardando transplante hepático foram avaliados pela ultrassonografia (por dois examinadores independentes: US1 e US2), pela ressonância magnética (RM) e pela tomografia computadorizada (TC). Os resultados foram comparados com os explantes hepáticos para avaliar os nódulos quanto à localização e ao diâmetro e foram classificados como macronódulo regenerativo, nódulo displásico, carcinoma hepatocelular, hemangioma e hepatocolangiocarcinoma. A sensibilidade e a especificidade foram calculadas através de tabelas 2 x 2 e o teorema de Bayes. O nível de significância adotado foi de 5% ( = 0,05). RESULTADOS: O exame anatomopatológico classificou 50 nódulos: 27(54%) como macronódulo regenerativo, 12(24%) como carcinoma hepatocelular, 9(18%) como nódulos displásicos, 1(2,0%) como hemangioma e 1(2,0%) como hepatocolangiocarcinoma. A sensibilidade e a especificidade para detecção de nódulos em geral foram 20%(10/50) e 95% para US1; 18%(9/50) e 98% para US2; 24%(12/50) e 96% para RM; 18%(09/50) e 96% para TC, respectivamente. A sensibilidade e a especificidade para a detecção de carcinoma hepatocelular foram 42%(05/12) e 87% para US1; 42%(05/12) e 89% para US2; 58%(07/12) e 87% para RM e 50%(06/12) e 92% para TC, respectivamente. CONCLUSÃO: Os métodos diagnósticos por imagem avaliados apresentaram sensibilidade e especificidade semelhantes para detecção de nódulos no fígado cirrótico / INTRODUCTION: Imaging diagnostic methods undergo constant and fast technological development, which has led to the improvement in the detection of hepatocellular carcinoma nodules in cirrhotic patients. OBJECTIVE: To prospectively compare the sensitivity and specificity of different imaging diagnostic methods in the detection of liver nodules in cirrhotic patients with the explanted liver. METHODS: Twenty patients awaiting liver transplant were assessed by ultrasonography (by two independent examiners: US1 and US2), magnetic resonance (MR) and multislice computed tomography (CT). The results were compared to the explanted livers to evaluate location and diameter of the nodules, which were classified as regenerative macronodule, dysplastic nodule, hepatocellular carcinoma, hemangioma and hepatocholangiocarcinoma. Sensitivity and Specificity were calculated through 2 x 2 Tables with Bayes Theorem. The level of significance was set at 5% ( = 0.05). RESULTS: The anatomopathological assessment classified 50 nodules: 27 (54%) as macroregenerative, 12 (24%) as hepatocellular carcinoma, 9 (18%) as dysplastic nodules, 1 (2%) as hemangioma and 1 (2%) as hepatocholangiocarcinoma. Sensitivity and specificity for general nodule detection were 20% (10/50) and 95% for US1, 18% (9/50) and 98% for US2, 24% (12/50) and 96% for MR and 18%(09/50) and 96% for CT, respectively. Sensitivity and specificity for hepatocellular carcinoma detection was 42% (5/12) and 87% for US1; 42% (5/12) and 89% for US2; 58% (7/12) and 87% for MR and 50% (6/12) and 92% for CT, respectively. CONCLUSION: The imaging diagnostic methods evaluated in the study showed similar sensitivity and specificity for nodule detection in the cirrhotic liver
8

O valor da ultra-sonografia na avaliação do traumatismo abdominal fechado / Value of ultrasound in the evaluation of blunt abdominal trauma

Shri Krishna Jayanthi 13 March 2008 (has links)
O trauma é uma das principais causas de morbidade e mortalidade em uma faixa etária que compreende adolescentes e adultos jovens, em proporção dominante do sexo masculino, com grande impacto econômico e social. Dentro do complexo do trauma, o traumatismo abdominal fechado (TAF) é um evento bastante freqüente e apresenta dificuldade na avaliação e manejo, uma vez que o exame clínico apresenta baixa sensibilidade e especificidade. A detecção de hemoperitônio é um dos métodos de avaliação indireta de possíveis lesões intra-abdominais, inicialmente pela punção abdominal diagnóstica e posteriormente pela lavagem peritoneal diagnóstica, que, apesar da eficácia, apresentam inconvenientes invasividade e impossibilidade na quantificação do hemoperitônio e no estadiamento da lesão, resultando em laparotomias não-terapêuticas. Os métodos de imagem prestam utilidade na investigação de lesões intra-abdominais, como a radiografia convencional e contrastada, ultra-sonografia (US) e a tomografia computadorizada (TC), esta última o método que apresenta melhor resolutividade, porém como desvantagens o custo, acessibilidade, o uso de radiação ionizante e meio de contraste e o deslocamento do paciente até o aparelho. A US apresenta-se como alternativa na avaliação inicial destes pacientes como método não invasivo e com potencial de dano virtualmente ausente, de baixo custo, de rápida realização e portátil. Apesar disso, este método também apresenta suas limitações, como na de lesões intra-abdominais na ausência de líquido livre. Este estudo foi realizado com a finalidade de estabelecer o desempenho da US neste contexto, permitindo racionalizar o uso da TC. Com essa finalidade foram estudados 163 pacientes atendidos pelo PS-HC/FMUSP, com a realização consecutiva de US e TC. A população estudada enquadra-se no perfil usual das vítimas de trauma, sendo 83% do sexo masculino e 56% na faixa etária entre 20 e 39 anos e em 73% dos casos eram vítimas de acidentes de trânsito. Eles foram trazidos ao serviço num tempo médio de 51 minutos, na maior parte estáveis e com nível de consciência satisfatório. A US levou em média 5 minutos para ser realizada e o intervalo médio até a realização da TC foi de155 minutos. Dos 163 pacientes 31 (19%) apresentaram US positiva e 132 (81%) apresentaram US negativa. Dos mesmos 163 pacientes 33 (20,2%) apresentaram TC positiva e 130 (79,8%) apresentaram TC negativa, resultando em sensibilidade de 73%, especificidade de 95%, acurácia de 90% em prevalência de 20%, com valor preditivo positivo de 77% e valor preditivo negativo de 93%. Corrigindo quanto à detecção de líquido livre, resulta-se em sensibilidade de 64%, especificidade de 98%, acurácia de 89% em prevalência de 27,6% e valor preditivo positivo de 93% e valor preditivo negativo de 88%. Ao se considerar a evolução dos pacientes, o desempenho da US foi semelhante ao da TC. Ao se considerar a necessidade de cirurgia a US apresentou acurácia de 87%, com valor preditivo positivo de 58% e valor preditivo negativo de 94%, próximo da TC, com 91% de acurácia, 67% de valor preditivo positivo e 97% de valor preditivo negativo. 24% dos pacientes com lesões intra-abdominais não apresentavam líquido livre, registrados pela TC. O espaço hepatorrenal e a pelve são os locais mais freqüentes do encontro de líquido, sendo 74% e 67% à US e 51% e 62% à TC, respectivamente. Entre os fatores que indicaram tendência de necessidade cirúrgica destaca-se a presença de líquido no espaço hepatorrenal (14 de 20 pacientes) e somatória dos bolsões de líquido acima de 3,0 cm. A detecção de lesões em víscera parenquimatosa foi baixa: 4 casos em 33, sendo que apenas 2 deles se confirmaram. Dentre os fatores que limitam o estudo pela US estão as lesões intraparenquimatosas que não se associam a líquido livre e hematomas retroperitoneais. A experiência do examinador não influenciou no número de casos positivos ou negativos, mas notou-se uma tendência a falso-positivos em examinadores mais experientes e falso-negativos em menos experientes. Assim, a US apresenta-se como ferramenta útil na avaliação inicial de traumatismo abdominal fechado, fornecendo subsídios para avaliação clínica, que associado aos demais dados, permite determinar a conduta. / Trauma is a major cause of morbidity and mortality in an age group including from teenagers to young adults, in a male dominat proportion, resulting in great economic and social impact. Within the complex of trauma, blunt abdominal trauma (BAT) is frequent event and presents difficulty in the evaluation and management since the clinical examination shows low sensitivity and specificity. The detection of hemoperitoneum is one of the methods of evaluation of possible indirect intra-abdominal injuries, initially using direct diagnostic abdominal paracentesis and posteriorly the diagnostic peritoneal lavage, that despite the effectiveness, have drawbacks such as invasiveness and the inability of hemoperitoneum quantification and the lesion staging, resulting in non-therapeutic laparotomies. Imaging methods provide useful information in the investigation of abdominal injuries, such as conventional and contrast radiology, ultrasound (US) and computed tomography (CT), which is the best effective method, but has its own drawbacks, such as cost, accessibility, use of ionizing radiation and contrast media and the displacement of the patient to the machine. US presents itself as an alternative in the initial evaluation of these patients as noninvasive method, with lack of harmfulness, low cost, fast answer and portability. Nevertheless, this method also has its limitations, as in cases of abdominal injuries without free fluid. This study was conducted in order to establish the performance of the US in this setting, allowing to rationalise the use of CT. For this purpose we studied 163 patients treated in the ER of HC/FMUSP, with the completion of consecutive US and CT. The population fits the usual profile of trauma victims, with 83% male, 56% in the age group between 20 and 39 years and in 73% of cases victims of traffic accidents. They were brought to the service in an average time of 51 minutes, mainly stable and with satisfactory level of consciousness. US took on average 5 minutes to be performed and the average interval until CT completion was 155 minutes. 31 (19%) of 163 patients showed positive US and 132 (81%) had negative US. 33 (20.2%) of the same 163 patients had positive CT and 130 (79.8%) had negative CT, resulting in a sensitivity of 73%, specificity of 95%, accuracy of 90% in 20% prevalence, with 77% of positive predictive value and 93% of negative predictive value. Correcting the detection of free fluid, results in 64% of sensitivity 98% of specificity 89% of accuracy in 28% of prevalence, with 93% of positive predictive value and 88% of negative predictive value of 88%. Considering the evolution of the patients, US performance was similar to that of CT. Considering need for surgery the US presented accuracy of 87%, positive predictive value of 58% and negative predictive value of 94%, near CT, with accuracy of 91%, predictive value of 67% and negative predictive value of 97%. 24% of patients with abdominal injuries did not have free fluid, as recorded by CT. The hepatorrenal space and pelvis were the most frequent sites fluid finding, 74% and 67% at US and 51% and 62% at CT, respectively. Among the factors that showed a tendency for surgery requirement were the presence of fluid in hepatorrenal space (14 of 20 patients) and the sum of liquid pockets over 3.0 cm. Detection of parenchymal lesions was low: 4 cases in 33, while only 2 of them confirmed. Among the factors that limit the US study are parenchymal lesions not associated with free fluid and retroperitoneal hematomas. Examiner experience did not influence the number of negative or positive cases, but there was a tendency to false positive with most experienced examiners and false negative with less experienced. Thus, US is an useful tool in the initial evaluation of blunt abdominal trauma, providing information for clinical evaluation, which associated with other data, tailors the management.
9

Sensibilidade e especificidade dos métodos de diagnóstico por imagem (ultrassonografia, ressonância magnética e tomografia computadorizada) na detecção de nódulos hepáticos no cirrótico com correlação histológica do explante / Sensitivity and specificity of imaging diagnostic methods (ultrasonography, magnetic resonanceand computed tomography) in the detection of liver nodules in cirrhotic patients, with histological correlation of the explanted liver

Fausto, Carmen Silvia Cerqueira do Val 13 December 2011 (has links)
INTRODUÇÃO: Os equipamentos dos métodos diagnósticos por imagem estão em constante e rápido desenvolvimento tecnológico, o que tem levado ao aprimoramento da detecção dos nódulos de carcinoma hepatocelular em pacientes cirróticos. OBJETIVO: Comparar prospectivamente a sensibilidade e a especificidade dos diferentes métodos diagnósticos de imagem na detecção de nódulos hepáticos em pacientes cirróticos com os explantes hepáticos. MÉTODOS: Vinte pacientes aguardando transplante hepático foram avaliados pela ultrassonografia (por dois examinadores independentes: US1 e US2), pela ressonância magnética (RM) e pela tomografia computadorizada (TC). Os resultados foram comparados com os explantes hepáticos para avaliar os nódulos quanto à localização e ao diâmetro e foram classificados como macronódulo regenerativo, nódulo displásico, carcinoma hepatocelular, hemangioma e hepatocolangiocarcinoma. A sensibilidade e a especificidade foram calculadas através de tabelas 2 x 2 e o teorema de Bayes. O nível de significância adotado foi de 5% ( = 0,05). RESULTADOS: O exame anatomopatológico classificou 50 nódulos: 27(54%) como macronódulo regenerativo, 12(24%) como carcinoma hepatocelular, 9(18%) como nódulos displásicos, 1(2,0%) como hemangioma e 1(2,0%) como hepatocolangiocarcinoma. A sensibilidade e a especificidade para detecção de nódulos em geral foram 20%(10/50) e 95% para US1; 18%(9/50) e 98% para US2; 24%(12/50) e 96% para RM; 18%(09/50) e 96% para TC, respectivamente. A sensibilidade e a especificidade para a detecção de carcinoma hepatocelular foram 42%(05/12) e 87% para US1; 42%(05/12) e 89% para US2; 58%(07/12) e 87% para RM e 50%(06/12) e 92% para TC, respectivamente. CONCLUSÃO: Os métodos diagnósticos por imagem avaliados apresentaram sensibilidade e especificidade semelhantes para detecção de nódulos no fígado cirrótico / INTRODUCTION: Imaging diagnostic methods undergo constant and fast technological development, which has led to the improvement in the detection of hepatocellular carcinoma nodules in cirrhotic patients. OBJECTIVE: To prospectively compare the sensitivity and specificity of different imaging diagnostic methods in the detection of liver nodules in cirrhotic patients with the explanted liver. METHODS: Twenty patients awaiting liver transplant were assessed by ultrasonography (by two independent examiners: US1 and US2), magnetic resonance (MR) and multislice computed tomography (CT). The results were compared to the explanted livers to evaluate location and diameter of the nodules, which were classified as regenerative macronodule, dysplastic nodule, hepatocellular carcinoma, hemangioma and hepatocholangiocarcinoma. Sensitivity and Specificity were calculated through 2 x 2 Tables with Bayes Theorem. The level of significance was set at 5% ( = 0.05). RESULTS: The anatomopathological assessment classified 50 nodules: 27 (54%) as macroregenerative, 12 (24%) as hepatocellular carcinoma, 9 (18%) as dysplastic nodules, 1 (2%) as hemangioma and 1 (2%) as hepatocholangiocarcinoma. Sensitivity and specificity for general nodule detection were 20% (10/50) and 95% for US1, 18% (9/50) and 98% for US2, 24% (12/50) and 96% for MR and 18%(09/50) and 96% for CT, respectively. Sensitivity and specificity for hepatocellular carcinoma detection was 42% (5/12) and 87% for US1; 42% (5/12) and 89% for US2; 58% (7/12) and 87% for MR and 50% (6/12) and 92% for CT, respectively. CONCLUSION: The imaging diagnostic methods evaluated in the study showed similar sensitivity and specificity for nodule detection in the cirrhotic liver
10

Recomendações operacionais para o serviço de enfermagem na tomografia computadorizada: subsídios para a organização do processo de trabalho

Santos, Sonia Regina Gonçalves dos January 2014 (has links)
Submitted by Fabiana Gonçalves Pinto (benf@ndc.uff.br) on 2016-06-01T18:28:06Z No. of bitstreams: 1 Sonia Regina Gonçalves dos Santos.pdf: 3014529 bytes, checksum: 002f404671a853dbcf1ce40bd8ab989d (MD5) / Made available in DSpace on 2016-06-01T18:28:06Z (GMT). No. of bitstreams: 1 Sonia Regina Gonçalves dos Santos.pdf: 3014529 bytes, checksum: 002f404671a853dbcf1ce40bd8ab989d (MD5) Previous issue date: 2014 / Mestrado Profissional em Enfermagem Assistencial / Situação-problema: Este estudo tem como enfoque as atividades desenvolvidas pelos membros da equipe de enfermagem na Tomografia Computadorizada, onde são realizados exames que podem requerer o uso de contraste ou não. O objeto deste estudo é o processo de trabalho de enfermagem na unidade de Tomografia Computadorizada de um hospital universitário, que envolve orientações e procedimentos técnicos relacionados à realização dos exames e está articulado à segurança do paciente, principalmente, no que se refere à administração de contrastes e na prevenção de complicações consideradas evitáveis. Objetivos: Caracterizar o processo de trabalho da equipe de enfermagem na Unidade de Tomografia Computadorizada. Elaborar recomendações operacionais do serviço de enfermagem que facilitem a redução dos fatores de risco no pré, trans e pós-exames. Discutir os procedimentos que competem à equipe de enfermagem, estabelecendo sua articulação com os princípios da segurança do paciente. Bases conceituais: O processo de trabalho em saúde, com ênfase na caracterização de seus momentos e, especificamente do trabalho de enfermagem. Também, após busca bibliográfica, foram referenciados estudos sobre tomografia computadorizada e a atuação de enfermagem nessa unidade. Metodologia: Trata-se de um estudo de caso com abordagem qualitativa, desenvolvido na unidade de tomografia computadorizada, cujos sujeitos são os 10 membros da equipe de enfermagem. Os procedimentos de coleta de dados foram dois, a observação sistemática direta e a técnica da vinheta. Resultados e discussão: O processo de trabalho de enfermagem na tomografia computadorizada tem como finalidade a realização do exame agendado, considerando à segurança do paciente. O objeto deste trabalho é caracterizado pelas necessidades de saúde do paciente, no que se referem ao seu estado de saúde e comorbidades. Apresenta como instrumentos, o conhecimento técnico científico, a própria unidade de tomografia computadorizada e materiais utilizados nos procedimentos técnicos. As atividades da equipe de enfermagem são as orientações pré e pós exames e os procedimentos técnicos de enfermagem, sobretudo relacionados à administração do meio de contraste por via endovenosa. Considerações Finais: O trabalho de enfermagem pode ser o diferencial na unidade de Tomografia Computadorizada, tendo em vista que na coordenação das atividades, do ponto de vista gerencial, a enfermeira promove o trabalho com os meios necessários, ou seja, recursos humanos e materiais, organizando-os com foco num atendimento humanizado e seguro que visa o atendimento das necessidades de saúde dos pacientes. Assim, o produto deste estudo consiste num instrumento orientador que apresenta os momentos operacionais do trabalho de enfermagem articulados a segurança do paciente denominado “Recomendações Operacionais para o Serviço de Enfermagem na Tomografia Computadorizada”. / Problem situation: This study focus on activities undertaken by members of the nursing team in CT, where tests that may require the use of contrast or not. The object of this study is the process of nursing job in CT unit of a university hospital, which involves technical guidelines and procedures related to the conduct of examinations and is articulated to patient safety, especially with regard to the administration of contrast and prevention of complications considered preventable. Objectives: To characterize the working process of the nursing staff in the unit CT. Develop operational recommendations of the nursing services that facilitate the reduction of risk factors before, during and post-tests. Discuss the procedures that compete for the nursing staff, establishing its linkage with the principles of patient safety. Conceptual foundations: The work process in health, with emphasis on characterization of their moments, and specifically the nursing work. Also, after literature search, studies on CT and the role of nursing in this unit were referenced. Methodology: This is a case study with a qualitative approach, developed in computed tomography unit, whose subjects are the 10 members of the nursing team. The procedures for data collection were two direct and systematic observation technique vignette. Results and discussion: The process of nursing job in computed tomography aims at the realization of scheduled examinations, including patient safety. The object of this work is characterized by the patient's health needs, as they relate to your health status and comorbidities. Presents as instruments, scientific expertise, the unit of computed tomography and materials used in technical procedures. The activities of the nursing staff are the pre and post testing guidelines and technical nursing procedures, especially related to the administration of contrast medium intravenously. Final Thoughts: The nursing job can be the difference in the CT unit, considering that the coordination of activities, from a managerial perspective, the nurse promotes the work with the necessary means, as, human and material resources, arranging them in a focused and humane care insurance that aims to meet the patients’ heath needs. Thus, the product of this study is a guiding tool that displays the operating times of articulated nursing work for patient safety called "Operational Recommendations for the Nursing Service in CT."

Page generated in 0.0842 seconds