• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Construção de fantomas homogêneos pediátricos de crãnio e tórax para otimização de imagens em radiografia computadorizada

Alves, Allan Felipe Fattori [UNESP] 31 July 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:19Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-07-31. Added 1 bitstream(s) on 2015-06-18T12:49:04Z : No. of bitstreams: 1 000831392.pdf: 1327749 bytes, checksum: c3b1aa57fef6b19f5e5e19cb0ffbcd09 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo a otimização de imagens de radiografia computadorizada (CR, do inglês, computed radiography) de crânio e tórax de pacientes pediátricos entre 1 e 5 anos de idade. Para atingir esse objetivo foram desenvolvidos fantomas homogêneos pediátricos, que simularam a faixa etária em estudo, a partir de exames retrospectivos de tomografia computadorizada (CT, do inglês, computed tomography). Nesse procedimento foi utilizado um algoritmo computacional para quantificar as espessuras médias de tecidos biológicos (tecido pulmonar, adiposo, mole e ósseo) presentes nas regiões anatômicas em estudo. Essas espessuras foram convertidas em materiais simuladores (lucite e alumínio) de modo a compor os fantomas homogêneos de crânio e tórax. As incertezas relativas no processo de quantificação dos exames de crânio foram de 3,5% para tecido mole e 9,5% para tecido ósseo. Na quantificação dos exames de tórax a incerteza relativa foi de 19,4% para o tecido pulmonar, 13,0% para o tecido mole e 20,0% para o tecido ósseo. O fantoma de tórax foi construído com 7,3 cm de lucite distribuídos em 4 placas de mesma espessura (15,0 x 15,0 x 1,82) cm³ arranjadas em dois pares, separadas por um espaçamento de ar de 2,86 cm. Duas placas de alumínio de (15,0 x 15,0 x 0,13) cm³ e (150,0 x 150,0 x 1,0) mm³ foram inseridas, respetivamente, entre os pares superior e inferior de lucite. O fantoma de crânio foi construído com 11,98 cm de lucite distribuídos em cinco placas de mesma espessura (15,0 x 15,0 x 2,33) cm³. Duas placas de alumínio (15,0 x 15,0 x 0,16) cm³ e (15,0 x 15,0 x 0,12) cm³ foram inseridas, respectivamente, entre os pares superior e inferior de lucite. Os fantomas homogêneos foram utilizados no processo de otimização de imagens em sistemas CR, para calibração do feixe de raios X. No processo de calibração foram determinadas técnicas-teste (combinação kVp e mAs), que produziram índices de ... / The aim of this work was to optimize computed radiography techniques of skull and chest for pediatric patients between 1 and 5 years old. To achieve this goal, pediatric homogenous phantoms were developed from retrospective computed tomography (CT) scans. In this procedure, a computational algorithm was used to quantify the average thickness of biological tissue (lung, fat, soft and bone tissue) present on the anatomic region under study. These thicknesses were converted into simulators materials (Lucite and aluminum) to build the homogeneous phantoms of skull and chest. The relative uncertainties in the quantification process of skull examinations were 3.5% for soft tissue and 9.5% for bone tissue. In the chest examination, the relative uncertainties were 19.4% for lung tissue, 13.0% for soft tissue and 20.0% for bone tissue. The chest phantom was constructed with 7.3 cm of lucite distributed in four plates of the same thickness (15.0 x 15.0 x 1.82) cm³ arranged in two pairs, separated by a spacing of 2.86 cm of air. Two aluminum plates (15.0 x 15.0 x 0.13) cm³ and (15.0 x 15.0 x 0.10) mm³ were inserted, respectively, between the upper and lower pairs of Lucite. The skull phantom was constructed with 11.98 cm of Lucite distributed in five plates of the same thickness (15.0 x 15.0 x 2.33) cm³. Two aluminum plates (15.0 x 15.0 x 0.16) cm³ and (15.0 x 15.0 x 0.12) cm³ were inserted between the upper and lower pairs of Lucite. These homogeneous phantoms were used in the optimization process for CR systems to determine test techniques (kVp and mAs combination), which produced levels of exposure around 1.96 lgM. The test images, obtained in this process, were used in the determination of physical parameters such as the effective detective quantum efficiency (eDQE) and contrast-detail. These parameters were associated with the optimal images of skull and chest for adult patients obtained in previous studies. Optimal images obtained in ...
2

Construção de fantomas homogêneos pediátricos de crãnio e tórax para otimização de imagens em radiografia computadorizada /

Alves, Allan Felipe Fattori. January 2014 (has links)
Orientador: José Ricardo de Arruda Miranda / Coorientador: Diana rodrigues de Pina / Banca: Sérgio Barbosa Duarte / Banca: Rozemeire Garcia Marques / Resumo: Este trabalho teve como objetivo a otimização de imagens de radiografia computadorizada (CR, do inglês, computed radiography) de crânio e tórax de pacientes pediátricos entre 1 e 5 anos de idade. Para atingir esse objetivo foram desenvolvidos fantomas homogêneos pediátricos, que simularam a faixa etária em estudo, a partir de exames retrospectivos de tomografia computadorizada (CT, do inglês, computed tomography). Nesse procedimento foi utilizado um algoritmo computacional para quantificar as espessuras médias de tecidos biológicos (tecido pulmonar, adiposo, mole e ósseo) presentes nas regiões anatômicas em estudo. Essas espessuras foram convertidas em materiais simuladores (lucite e alumínio) de modo a compor os fantomas homogêneos de crânio e tórax. As incertezas relativas no processo de quantificação dos exames de crânio foram de 3,5% para tecido mole e 9,5% para tecido ósseo. Na quantificação dos exames de tórax a incerteza relativa foi de 19,4% para o tecido pulmonar, 13,0% para o tecido mole e 20,0% para o tecido ósseo. O fantoma de tórax foi construído com 7,3 cm de lucite distribuídos em 4 placas de mesma espessura (15,0 x 15,0 x 1,82) cm³ arranjadas em dois pares, separadas por um espaçamento de ar de 2,86 cm. Duas placas de alumínio de (15,0 x 15,0 x 0,13) cm³ e (150,0 x 150,0 x 1,0) mm³ foram inseridas, respetivamente, entre os pares superior e inferior de lucite. O fantoma de crânio foi construído com 11,98 cm de lucite distribuídos em cinco placas de mesma espessura (15,0 x 15,0 x 2,33) cm³. Duas placas de alumínio (15,0 x 15,0 x 0,16) cm³ e (15,0 x 15,0 x 0,12) cm³ foram inseridas, respectivamente, entre os pares superior e inferior de lucite. Os fantomas homogêneos foram utilizados no processo de otimização de imagens em sistemas CR, para calibração do feixe de raios X. No processo de calibração foram determinadas técnicas-teste (combinação kVp e mAs), que produziram índices de ... / Abstract: The aim of this work was to optimize computed radiography techniques of skull and chest for pediatric patients between 1 and 5 years old. To achieve this goal, pediatric homogenous phantoms were developed from retrospective computed tomography (CT) scans. In this procedure, a computational algorithm was used to quantify the average thickness of biological tissue (lung, fat, soft and bone tissue) present on the anatomic region under study. These thicknesses were converted into simulators materials (Lucite and aluminum) to build the homogeneous phantoms of skull and chest. The relative uncertainties in the quantification process of skull examinations were 3.5% for soft tissue and 9.5% for bone tissue. In the chest examination, the relative uncertainties were 19.4% for lung tissue, 13.0% for soft tissue and 20.0% for bone tissue. The chest phantom was constructed with 7.3 cm of lucite distributed in four plates of the same thickness (15.0 x 15.0 x 1.82) cm³ arranged in two pairs, separated by a spacing of 2.86 cm of air. Two aluminum plates (15.0 x 15.0 x 0.13) cm³ and (15.0 x 15.0 x 0.10) mm³ were inserted, respectively, between the upper and lower pairs of Lucite. The skull phantom was constructed with 11.98 cm of Lucite distributed in five plates of the same thickness (15.0 x 15.0 x 2.33) cm³. Two aluminum plates (15.0 x 15.0 x 0.16) cm³ and (15.0 x 15.0 x 0.12) cm³ were inserted between the upper and lower pairs of Lucite. These homogeneous phantoms were used in the optimization process for CR systems to determine test techniques (kVp and mAs combination), which produced levels of exposure around 1.96 lgM. The test images, obtained in this process, were used in the determination of physical parameters such as the effective detective quantum efficiency (eDQE) and contrast-detail. These parameters were associated with the optimal images of skull and chest for adult patients obtained in previous studies. Optimal images obtained in ... / Mestre
3

Avaliação do desenvolvimento cardíaco neonatal em cordeiros / Evaluation of heart development in neonatal lambs

Ulian, Carla Maria Vela [UNESP] 31 July 2015 (has links) (PDF)
Made available in DSpace on 2016-07-01T13:10:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-07-31. Added 1 bitstream(s) on 2016-07-01T13:14:10Z : No. of bitstreams: 1 000865898.pdf: 1961138 bytes, checksum: 38a271e6faf293c5f20f689c97bd0b14 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Durante o primeiro mês de vida ocorrem as principais adaptações cardiocirculatórias que permitirão ao indivíduo chegar à vida adulta. Este trabalho visou descrever as possíveis diferenças no coração de um recémnascido a partir da avalição cardíaca em cordeiros durante os primeiros 35 dias de idade, fornecendo dados que poderão ser úteis na Medicina Veterinária e nos diversos protocolos experimentais da Medicina, que utiliza os ovinos como modelo. Foram realizadas avaliações cardíacas semanais que consistiram em: eletrocardiograma e eletrocardiograma ambulatorial/sistema Holter, parâmetros ecodopplercardiográficos, exame radiográfico cardíaco, pressão arterial sistêmica (por método Doppler e oscilométrico). Utilizou-se 20 cordeiros, clinicamente saudáveis abrangendo o período neonatal. Para os valores da frequência cardíaca, respiratória e tamanho da silhueta cardíaca, foram observadas diminuições com o passar da idade. A pressão invasiva obtida em normotensão (70 mmHg) teve média de 119,14 ± 23,59 mmHg. Na comparação entre os métodos com a invasiva, pode-se observar que a aferição como Doppler superestimou em 4,24 mmHg (+4%) e em 16,56 mmHg (+16%) com o método oscilométrico. Quanto aos resultados do ecodopplercardiograma, o diâmetro da aorta (Ao), átrio esquerdo (AE), o diâmetro do ventrículo esquerdo no final da diástole (DVEFD), diâmetro no final da diástole (DFD), diâmetro no final da sístole (DFS), espessura da parede livre do ventrículo esquerdo na diástole (EPLVED) e separação entre o ponto E e o septo (SSPE) apresentaram aumento progressivo quando comparado ao nascimento. A relação AE:Ao não sofreu alteração significativa até o final do estudo, assim como a fração de ejeção e encurtamento (FE% e ΔD%). Na derivação DII no plano frontal do eletrocardiograma observou-se diferença com diminuição a partir do sétimo dia na duração do intervalo PR e da onda T, e na... / During the first month of life occur the main cardiocirculation adaptations that allow individuals to reach adulthood. This work aimed to describe the possible differences in the heart of the newborn from the cardiac assessment in the Ile de France breed lambs during the first 35 days of age, providing data that may be useful in veterinary medicine and in the different experimental protocols of medicine, which uses this species as a model. Cardiac evaluations were carried out weekly by electrocardiogram and ambulatory electrocardiogram/Holter system, echodopplercardiografic parameters, cardiac silhouette and determination of VHS (vertebral heart size) by radiography, systemic arterial pressure by Doppler and oscillometric method. Twenty clinically healthy lambs were used into the neonatal period. For the rate values of the heart, breath and cardiac silhouette size was observed decrease as age increase. Invasive pressure obtained in normotension (70 mmHg) averaged was 119.14 ± 23.59 mmHg. In comparison between the methods above with the invasive showed that the measurement as overrated in Doppler about 4.24 mmHg (+4%) and 16.56 mmHG (+16%) with the oscillometric method. The echodopplercardiogram analysis was HR between 212 and 134 bpm from birth to 35th day. The aorta diameter (Ao), left atrium (LA), left ventricular diameter in end-diastole (LVd), end-diastole diameter (EDD), end-systole diameter (ESD), left ventricular wall thickness diastole (LVWd), septum E point (SEP) showed progressive increase when compared to birth. The relationship LA:Ao did not suffer significant change until the end of the study, as well as the ejection fraction and shortening (EF and FS). In the DII derivation in the frontal plane of the electrocardiogram was observed difference with decreased from the seventh day in the duration of the PR interval and T wave, and the amplitude of the wave P, R and T. The QT interval ... / FAPESP: 12/24833-9
4

Avaliação do desenvolvimento cardíaco neonatal em cordeiros /

Ulian, Carla Maria Vela. January 2015 (has links)
Orientador: Simone Biagio Chiacchio / Coorientador: Maria Lúcia Gomes Lourenço / Banca: Maria Jaqueline Mamprim / Banca: Rogério Martins Amorim / Banca: Letícia Ferrari Crocomo / Banca: Moacir Fernandes de Godoy / Resumo: Durante o primeiro mês de vida ocorrem as principais adaptações cardiocirculatórias que permitirão ao indivíduo chegar à vida adulta. Este trabalho visou descrever as possíveis diferenças no coração de um recémnascido a partir da avalição cardíaca em cordeiros durante os primeiros 35 dias de idade, fornecendo dados que poderão ser úteis na Medicina Veterinária e nos diversos protocolos experimentais da Medicina, que utiliza os ovinos como modelo. Foram realizadas avaliações cardíacas semanais que consistiram em: eletrocardiograma e eletrocardiograma ambulatorial/sistema Holter, parâmetros ecodopplercardiográficos, exame radiográfico cardíaco, pressão arterial sistêmica (por método Doppler e oscilométrico). Utilizou-se 20 cordeiros, clinicamente saudáveis abrangendo o período neonatal. Para os valores da frequência cardíaca, respiratória e tamanho da silhueta cardíaca, foram observadas diminuições com o passar da idade. A pressão invasiva obtida em normotensão (70 mmHg) teve média de 119,14 ± 23,59 mmHg. Na comparação entre os métodos com a invasiva, pode-se observar que a aferição como Doppler superestimou em 4,24 mmHg (+4%) e em 16,56 mmHg (+16%) com o método oscilométrico. Quanto aos resultados do ecodopplercardiograma, o diâmetro da aorta (Ao), átrio esquerdo (AE), o diâmetro do ventrículo esquerdo no final da diástole (DVEFD), diâmetro no final da diástole (DFD), diâmetro no final da sístole (DFS), espessura da parede livre do ventrículo esquerdo na diástole (EPLVED) e separação entre o ponto E e o septo (SSPE) apresentaram aumento progressivo quando comparado ao nascimento. A relação AE:Ao não sofreu alteração significativa até o final do estudo, assim como a fração de ejeção e encurtamento (FE% e ΔD%). Na derivação DII no plano frontal do eletrocardiograma observou-se diferença com diminuição a partir do sétimo dia na duração do intervalo PR e da onda T, e na... / Abstract: During the first month of life occur the main cardiocirculation adaptations that allow individuals to reach adulthood. This work aimed to describe the possible differences in the heart of the newborn from the cardiac assessment in the Ile de France breed lambs during the first 35 days of age, providing data that may be useful in veterinary medicine and in the different experimental protocols of medicine, which uses this species as a model. Cardiac evaluations were carried out weekly by electrocardiogram and ambulatory electrocardiogram/Holter system, echodopplercardiografic parameters, cardiac silhouette and determination of VHS (vertebral heart size) by radiography, systemic arterial pressure by Doppler and oscillometric method. Twenty clinically healthy lambs were used into the neonatal period. For the rate values of the heart, breath and cardiac silhouette size was observed decrease as age increase. Invasive pressure obtained in normotension (70 mmHg) averaged was 119.14 ± 23.59 mmHg. In comparison between the methods above with the invasive showed that the measurement as overrated in Doppler about 4.24 mmHg (+4%) and 16.56 mmHG (+16%) with the oscillometric method. The echodopplercardiogram analysis was HR between 212 and 134 bpm from birth to 35th day. The aorta diameter (Ao), left atrium (LA), left ventricular diameter in end-diastole (LVd), end-diastole diameter (EDD), end-systole diameter (ESD), left ventricular wall thickness diastole (LVWd), septum E point (SEP) showed progressive increase when compared to birth. The relationship LA:Ao did not suffer significant change until the end of the study, as well as the ejection fraction and shortening (EF and FS). In the DII derivation in the frontal plane of the electrocardiogram was observed difference with decreased from the seventh day in the duration of the PR interval and T wave, and the amplitude of the wave P, R and T. The QT interval ... / Doutor

Page generated in 0.0485 seconds