• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 316
  • 4
  • 3
  • Tagged with
  • 330
  • 330
  • 209
  • 206
  • 57
  • 55
  • 45
  • 44
  • 43
  • 38
  • 38
  • 34
  • 33
  • 33
  • 32
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Detecção de oocistos de Cryptosporidium, spp, em águas de abastecimento superficiais e tratadas da região metropolitana de São Paulo. / Detection of Cryptosporidium spp. in raw and drinking waters in São Paulo city.

Muller, Ana Paula Bortolotti 28 February 2000 (has links)
O protozoário parasita Cryptosporidium emergiu como um dos mais importantes contaminantes da água responsável por vários surtos de criptosporidiose, afetando mais de 427.000 indivíduos em todo o mundo. Até hoje, pelo menos oito espécies do gênero Cryptosporidium foram descritas, mas somente o C. parvum têm sido associado às doenças gastroentestinais em humanos. A criptosporidiose pode ser fatal para imunocomprometidos e pode debilitar severamente indivíduos imunocompetentes. Os oocistos de Cryptosporidium são resistentes às pressões ambientais, podendo sobreviver por vários meses no ambiente aquático e são também resistentes à desinfecção por cloro utilizada no tratamento convencional de água. Este estudo teve como objetivos determinar a ocorrência e densidade de Cryptosporidium em amostras de água superficiais e tratadas (após floculação, coagulação, sedimentação, filtração e desinfecção) coletadas em duas Estações de Tratamento de Água da cidade de São Paulo. A relação entre os parâmetros da qualidade da água e a ocorrência de oocistos de Cryptosporidium também foi analisada. As amostras de água foram coletadas em intervalos mensais durante o período de um ano. Estas amostras foram concentradas por ''precipitação do carbonato de cálcio'' (VESEY et alii, 1993a) e através da técnica da ''membrana filtrante'' (ALDOM & CHAGLA, 1994). Os oocistos foram identificados pela técnica de imunofluorescência direta e a presença destes foi confirmada por microscopia de contraste de fase. Os níveis de coliformes totais e E.coli nas amostras de água foram determinados pela técnica dos tubos múltiplos, empregando substrato fluorogênico e cromogênico (Colilert 18, Iddex). De um total de 24 amostras analisadas, de cada tipo de água (sendo 12 de cada Estação de Tratamento de Água), os oocistos foram detectados em 75% das amostras de água bruta e em 12,5% das amostras de água tratada, quando estas foram concentradas por precipitação química e em 73,91% das amostras de água bruta e 33,33% das amostras das água tratada, quando as mesmas foram concentradas pela técnica da membrana filtrante. A densidade de oocistos de Cryptosporidium não apresentou correlação significativa com indicadores microbiológicos e os parâmetros físico-químicos de qualidade da água (p > 0,05). Os resultados obtidos sugeriram que o tratamento de água convencional é ineficaz para a remoção de oocistos, ressaltando a necessidade de estabelecer programas de gerenciamento em bacias hidrográficas (mananciais) que efetivamente garantam a baixa densidade de oocistos de Cryptosporidium em águas / The protozoan parasite Cryptosporidium has emerged as one of the most important contaminants of water, causing waterbone outbreaks of criptosporidiosis which have affected more than 427.000 individuals worldwide. At least 8 species of the genus Cryptosporidium has been associated with gastrointestinal disease in humans. Cryptosporidiosis can be life threatening to immunocompromised humans and can severely debilitate immunocompetent people. Cryptosporidium oocysts are environmentally robust and can survive in aquatic environments for months. Oocysts are resistant to standard chlorination disinfection used for drinking water treatment. The aims of this study were to determine the occurrence and the levels of Cryptosporidium in raw water samples and in drinking water (after flocculation, coagulation, sedimentation, filtration and disinfection) collected in two potable water treatment plants of the city of São Paulo. The relationship between parameters of water quality and the occurrence of Cryptosporidium were also analysed. Samples were collected at monthly intervals for a year. The samples were concentrated by flocculation (VESEY et alii, 1993a) and by membrane filtration (ALDOM & CHAGLA, 1994). The oocysts were identified by direct immunofluorescence assay and the presence was confirmed by phase contrast microscopy. The levels of coliforms and E.coli in the water samples were determined by the multiple tube technique using chromogenic and fluorogenic substrate (Colilert 18, Iddex). From a total of 24 samples of the each type of water investigated (12 oh the each potable water treatment plant), oocysts were detected in 75% of raw water and in 12,5% of drinking water samples, when concentrated by flocculation and in 73,91% of raw water samples and in 33,33% of drinking water samples when concentrated by membrane filtration. Cryptosporidium oocysts levels in the samples investigated was not significantly associated with microbiological indicators and water quality parameters (p > 0,05). The results suggested that the conventional treatment of water is ineffective in removing the oocysts, highlighting the necessity of establishing water catchment management programs which effectively ensure low levels of Cryptosporidium in raw water supplied to the treatment plants.
82

Efeitos do recebimento do lodo da estação de tratamento de água pelo sistema de tratamento de esgoto por lodo ativado em bateladas e aeração prolongada do município de Juquitiba - SP. / Effects of the accepting water treatment plants (WTP) residuals at wastewater treatment plant (WWTP) using SBR activated-sludge process with extended aeration in the city of Juquitiba, SP.

Sundefeld Júnior, Gilberto Carlos 09 May 2007 (has links)
Existem algumas diferentes soluções técnicas de engenharia para a finalidade de tratamento e disposição final dos resíduos gerados em ETA\'s aplicáveis aos diferentes sistemas de tratamento de água. Porém, depara-se com estações consolidadas sem os sistemas de tratamento da fase sólida, onde nem sempre a melhor solução para o tratamento é a mais econômica ou ainda, é a possível de ser implantada. Com isso propôs-se neste estudo avaliar a capacidade da estação de tratamento de esgotos receber os resíduos da ETA, da cidade de Juquitiba - SP, via rede coletora de esgotos, uma vez que existe na ETE o sistema de tratamento dos sólidos ali gerados. Este estudo teve como objetivo verificar as transformações do fósforo e do nitrogênio ao longo do sistema de esgotos, verificar as variações das concentrações de DBO, DQO e sólidos em suspensão, assim como verificar se é possível a manutenção de um equilíbrio consistente controlado pela idade do lodo. A estação de tratamento de água produz resíduos que resultariam em um acréscimo médio de 133 mg/L de sólidos no esgoto e ao longo deste estudo atingiu-se 74 mg/L. Esta contribuição representou, aproximadamente, uma situação em que o porte da ETA é o dobro da ETE receptora dos resíduos. Como conseqüência as concentrações dos sólidos em suspensão totais nos reatores biológicos aumentaram em média 15% e no efluente tratado 73%, ainda a produção de lodo biológico aumentou a ordem de 40%. Ocorreu a diminuição da concentração de fósforo total no efluente tratado da ETE em 29% e 51% para os reatores 1 e 2, respectivamente e da concentração de fósforo solúvel em 74% e 79% para os reatores 1 e 2, respectivamente. Ocorreu a diminuição da remoção média de NKT em 18% e na remoção média de N-NH3 em 13%. Ocorreu, ainda, a diminuição da remoção dos parâmetros DBO e DQO em 4% após o lançamento do lodo da ETA no sistema de esgotos. Pode-se então admitir que ETE\'s pelo processo de lodo ativado com aeração prolongada e com reatores seqüenciais em bateladas são adequados para o recebimento de lodo proveniente de ETA\'s, desde que projetada para atender a essa função complementar, especialmente no que se refere às unidades de desidratação de lodo. / There are different technical engineering solutions for the treatment and final disposal of water treatment plants (WTPs) residuals. Discharge of WTP residual to a wastewater treatment plant (WWTP) is a technical solution in evidence. Therefore, the purpose of this study was to evaluate the capacity of the WWTP using sequencing batch reactor (SBR) activated-sludge process (with two reactors named reactor 1 and 2) in the city of Juquitiba, State of São Paulo, to receive the WTP residuals by gravity sanitary sewers. For this purpose the following points were checked: phosphorous and nitrogen transformations in the sewer systems, variations in BOD , COD and suspended solids (SS) concentrations and the possibility of maintaining a consistent balance system controlled by solids retention time. There was an average increase of 74 mg of suspended solids per liter in incoming sewage by the discharge of WTP residuals to sanitary sewers. Suspended solids concentrations in the biological reactors increased 15 percent in average and 73 percent in the final effluent. Production of waste activated-sludge increased by 40 percent. There was a decrease of 29 percent and 51 percent of total phosphorus concentration in the effluent in reactors 1 and 2, respectively, and of 74 percent and 79 percent of soluble phosphorus concentration in reactors 1 and 2, respectively. Total Kjeldahl nitrogen removal efficiency was reduced by 18 percent and ammonia nitrogen removal efficiency by 13 percent. BOD and DQO parameters for efficiency removal showed a decrease of 4 percent after the discharge of WTP residual to sanitary sewers. In view of these results it can be admitted that WWTPs using sequencing batch reactor activated-sludge process are suitable to receive WTP residuals since adequately designed for this complementary function.
83

Seleção de tecnologias de tratamento de água para pequenas e médias comunidades brasileiras considerando aspectos ambientais / Technologies selection for drinking water treatment for small and medium brazilian communities considering environmental aspects

Sakamoto, Jaqueline Akiko 27 August 2013 (has links)
As estações de tratamento de água - ETAs são fundamentais para a melhoria do saneamento ambiental de um país. No Brasil, a avaliação dos impactos ambientais negativos em ETAs se limita normalmente aos resíduos gerados no tratamento da água. As alterações ambientais decorrentes da construção e operação são desconsideradas na escolha das tecnologias, fato que podem prejudicar o alcance da sustentabilidade ambiental. O trabalho desenvolveu um método baseado na adaptação do Método Battelle-Columbus visando a seleção das tecnologias de tratamento de água e dos seus resíduos conforme o critério de impacto ambiental mínimo. O método é válido para comunidades brasileiras de pequeno e médio porte, as quais podem ser beneficiadas com vazões de projeto das ETAs entre 10 L/s e 100 L/s. As combinações dos processos e operações de tratamento nas ETAs e estações de tratamento dos resíduos- ETRs- para cinco diferentes vazões de projeto (10, 20, 40, 70 e 100 L/s) possibilitaram a avaliação de 205 projetos - 180 projetos extraídos de Sabogal Paz (2007; 2010) e 25 elaborados nesta pesquisa com o filtro ascendente em areia grossa na ETA de dupla filtração (DF2). Apenas os impactos ambientais negativos foram considerados na avaliação ambiental. A estimativa da magnitude de cada aspecto ambiental foi baseada nos quantitativos referentes à construção (requerimentos de área, concreto, chapa de aço, meio filtrante e camada suporte) e operação (consumo de energia elétrica e produtos químicos, geração de resíduos líquidos e sólidos) das ETAs e ETRs. Os resultados foram condizentes com a literatura, pois as ETAs menos robustas apresentaram um menor potencial de degradação e as tecnologias com maior área de implantação e consumo de energia elétrica foram mais impactantes. De fácil interpretação, o método é uma ferramenta que auxilia na tomada de decisão das ETAs a serem instaladas nos municípios brasileiros e que contribui para a mudança na abordagem normalmente adotada na seleção das tecnologias de tratamento de água. Com a questão ambiental como parte integrante do processo de escolha, uma visão mais abrangente e sustentável é alcançada para o setor de saneamento no país. / The water treatment plants (WTPs) are fundamental for the improvement of the environmental sanitation in a country. In Brazil, the negative environmental impacts assessment is usually limited in to the sludge produced in water treatment processes. Environmental impacts that occur during construction and operation of water treatment plants are not considered in the selection of technologies, what might prejudice the achievement of environmental sustainability. This research has developed a method based on the adaptation of the Method Battelle-Columbus to select the technologies for water treatment and sludge, according to the minimum environmental impact criteria. The method is effective for small and medium Brazilian communities of the country that can benefit with project flows that uses project flows of WTP between 10 and 100 L/s. Combinations of treatment processes and operations in WTPs and in waste treatment plants, for five different project flows (10, 20, 40, 70 and 100 L/s) enabled the evaluation of 205 projects- 180 projects according to Sabogal Paz (2007, 2010) and 25 projects were elaborated in this research with coarse sand upflow filter on the WTP of double filtration (DF2). Only the negative environmental impacts have been considered in the environmental assessment. The estimation of the magnitude of each environmental aspect was based on quantitative concerning the construction (area requirements, concrete, steel, filter media and support layer) and operation (electric energy consumption and chemicals, liquid and solid residue generation) of WTPs and waste treatment plants. The results were consistent with the literature because the less robust WTPs had a lower potential of degradation and the technologies with greater implantation area and electric energy consumption were more impactful. Easy to be interpreted, the method is a tool that can assist in decision making of WTPs to be installed in Brazilian municipalities and contributes to the change in the approach usually adopted in the technologies selection. On the integration of environmental issues as part of the selection process, a more comprehensive and sustainable solution is achieved to the sanitation sector in the country.
84

Emprego da ferramenta CFD para representação da estrutura de escoamento de uma unidade de flotação em escala piloto tratando água para abastecimento / Use of CFD tool to represent the flow structure on a pilot scale flotation unitytreating water for supply

Pinto, Stephanie Iris Graciano 31 October 2013 (has links)
A flotação por ar dissolvido é atualmente muito utilizada e reconhecida como uma técnica eficiente para o tratamento de águas para abastecimento. Diversos estudos vêm sendo realizados para aprimoramento desta técnica e das características físicas das unidades, dentre estes o estudo do emprego de ferramenta de simulação computacional do escoamento (CFD) para melhor compreensão da estrutura de escoamento dentro dos tanques e da influência de diversos parâmetros no processo, de modo a auxiliar nas etapas de projeto e melhorias das unidades. Neste contexto, o presente trabalho propôs a verificação do potencial de utilização da ferramenta computacional CFD para representação do escoamento em uma unidade piloto de flotação por ar dissolvido de grande porte. A pesquisa foi dividida em cinco etapas: as Etapas I e II compreenderam a validação dos modelos adotados através da variação do diâmetro de microbolhas e comparação com resultados experimentais de ADV de Escher (2011), na Zona de Separação, e de Patrizzi (2005), em ambas as zonas do reator; na Etapa III, foram realizadas quatro simulações com uma das configurações da Etapa I, variando a condição de contorno de superfície e de saída do flotador, de modo a calibrar o modelo; na Etapa IV, foram realizadas cinco simulações com um dos modelos da Etapa III, variando a geometria da unidade para análise da influência destas na estrutura de escoamento; e, finalmente, na Etapa V, uma mesma configuração de operação e geometria foi empregada em três variações do modelo, por meio de mudanças na condição de contorno de saída e na abordagem Eulerian-Eulerian ou Eulerian-Lagrangian. Nas Etapas I, II e V, a superfície d\'água foi modelada como parede porosa sem atrito (permitindo a saída do ar), nas Etapas III e IV, esta foi modelada como superfície livre. Além dos resultados experimentais de ADV das autoras citadas, foram utilizados como base para avaliação dos resultados numéricos, os valores de concentração de ar e gradiente de velocidade. Os resultados mostraram que as simulações com parede porosa subestimaram os vetores de velocidade próximos à superfície, porém apresentaram resultados de concentração de ar próximos ao esperado. Em contrapartida, as simulações com superfície livre foram capazes de reproduzir melhor a turbulência próxima à superfície d\'água, entretanto, não descreveram bem a concentração de microbolhas no meio líquido. / The dissolved air flotation is currently widely used and recognized as an effective technique for the treatment of water for supply. Several studies have been conducted to perfect this technique and the physical characteristics of units, among them the application of computational flow simulation (CFD) to better understand the flow structure inside the tanks and the influence of various parameters on the process, to aid in the design steps and improvements of the units. In this context, the present study aimed to verify the potential use of CFD computational tool to represent the flow in a large scale pilot unit of dissolved air flotation. The research was divided into five stages: Stages I and II comprised the validation of the adopted models by varying the diameter of microbubbles and comparison with experimental results of ADV from Escher (2011), in the Separation Zone, and Patrizzi (2005) in both reactor zones; in Step III, four simulations were carried out with a group of settings of Step I, varying boundary conditionsof the surface and outlet of the flotation unit, in order to calibrate the model; in Step IV five simulations were performed using one of the models of Step III, varying the geometry of the unit to analyze the influence on the flow structure; and finally, in Step V, the same geometry and operating configuration was tested in three variants of the model, by changingboundary conditions and outlet in Eulerian-Eulerian or Eulerian- Lagrangian approaches. In Steps I, II and V, the water surface was modeled as a frictionless porous wall (allowing air to scape), while in Steps III and IV, it was modeled as a free surface. In addition to the ADV experimental results of cited authors, were also used as basis for evaluating the numerical results, values of air concentration and velocity gradient. The results showed that simulations with porous wall underestimated the velocity vectors near the surface, although, these results showed air concentration close to expected values. In contrast, simulations with free surface were able to better represent the turbulence near the water surface, however, were unable to describe the concentration of microbubbles in the liquid medium.
85

Remoção de células de Microcystis sp por pré-cloração, coagulação, filtração direta e pós-cloração em escala de bancada / Removal of cells of Microcystis sp by prechlorination, coagulation, direct filtration and poschlorination in jar-test experiment

Pereira, Glauce Guimarães 29 July 2005 (has links)
Por suas características fisiológicas, cianobactérias se adaptam rapidamente em sistemas eutrofizados e geralmente predominam na comunidade fitoplanctônica. O crescimento excessivo desses microrganismos resulta em dificuldades e acréscimo nos custos do tratamento de água para consumo humano. Além da rápida colmatação dos filtros devido à grande massa orgânica, atribuição de cor e sabor, cianobactérias podem se apresentar tóxicas, liberar na água metabólitos nocivos e também serem precursoras na formação de subprodutos. Assim, este trabalho teve por objetivo avaliar a eficiência de remoção da cianobactéria Microcystis sp por pré-oxidação com cloro, coagulação com sulfato de alumínio, filtração direta e pós-cloração em escala de bancada, baseando-se nos parâmetros de turbidez, contagem celular, distribuição de tamanho e contagem de partículas, carbono orgânico dissolvido e subprodutos organoalogenados. Para atingir tal objetivo foi necessária a realização de experimentos para determinação da dosagem e do tempo de contato de cloro livre e a construção de diagramas de coagulação-filtração. Paralelamente foi determinado o Potencial de Formação de Trialometanos. A presença de cianibactérias não pareceu favorecer a formação de subprodutos indesejados da cloração. O ensaio final foi realizado com pré-cloração, coagulação, filtração e pós-cloração. Para a água pré-clorada com 2,5 mg/L de cloro livre, coagulada com 4 mg/L de sulfato de alumínio comercial, filtrada em areia com tamanho de grãos entre 0,3 a 0,59 mm e pós-clorada com 3,0 mg/Lde cloro livre, a turbidez reduziu de 2,89 para 0,36 uT, redução de 88%. A contagem celular mostrou decréscimo de 99,98% e a contagem de partículas reduziu 96,3% na faixa de tamanho de 3 a 20 \'mü\'m. Também foi observado aumento do carbono orgânico dissolvido com o aumento da dosagem de cloro livre. / Because of their physiological characteristics, cyanobacteria are able to adapt themselves quickly in eutrophic systems and are usually predominant in water bodies. The excessive growth of these organisms results in an increase in water treatment costs and other problems. Beside faster filter clogging due to the large amounts of cyanobacteria, these organisms may be toxic, release toxic metabolites and act as nuisance subproducts precursors. The aim of this work is to evaluate Microcystis sp cyanobacteria removal efficiency by chlorine preoxidation, aluminum sulfate coagulation, direct filtration and post-chlorination in bench-scale experiments. The removal efficiency was evaluated based on turbidity, cell counts, particle size distribution, dissolved organic carbon and halogenated organic subproducts. To reach the objectives it was first necessary to do experiments to determine free chlorine dose and contact time and also prepare coagulation-filtration diagrams. The trihalomethane formation potential was also determined, showing the presence of cyanobacteria did not contribute to subproduct formation. The final test, involving prechlorination, coagulation, filtration and post-chlorination, showed excellent Microcystis sp removal results. For prechlorinated water with 2,5 mg/L of free chlorine, coagulated with 4 mg/L of aluminum sulfate, filtered in a sand bed with grain size between 0,3 and 0,59 mm and post-chlorinated with 3,0 mg/L of free chlorine, turbidity was reduced from 2,89 to 0,36 uT, a 88% decrease. Cell count showed a 99,98% decrease and the particle count was reduced in 96,3% in the size range of 3 to 20 \'mü\'m. An increase in dissolved organic carbon related to the increase in the free chlorine dose was also noted.
86

Proposta de um sistema de gestão empregando instrumentação inteligente e redes de campo na automação do processo de tratamento de água. / Proposal of a management system using intelligent and field networks in the water treatment process automation.

Souza, Marcelo de 23 October 2006 (has links)
A necessidade de gestão e controle otimizados dos processos está cada vez mais presente nos dias atuais. Assim sendo, devido também à exigência de integrar tais processos aos diversos setores da economia, têm-se exigido respostas cada vez mais eficientes da engenharia da automação. Os recursos hídricos do planeta e os respectivos processos de tratamento e distribuição também têm sido alvo de pesquisas destinadas ao desenvolvimento de novas tecnologias e metodologias de automação para melhorar a eficiência dos sistemas de controle e gestão. Este trabalho de pesquisa apresenta uma nova proposta sistêmica de gestão de sistemas de tratamento de água com base nos atuais desenvolvimentos científicos e tecnológicos da instrumentação inteligente e das redes de campo. Assim sendo, esperase contribuir para a otimização operacional de sistemas de tratamento de água, uma vez que uma plataforma de automação mais poderosa permitirá implementar algoritmos de controle mais rigorosos e eficientes. / The need for optimized process management and control is increasingly present nowadays. Therefore, due to the necessity of integrating such processes into several economic segments, there is a pressing demand for more efficient responses from the automation engineering sector. The planet?s water resources and respective water treatment and supply processes have also been the subject matter of research for the development of new automation technologies and methodologies to improve the efficiency of control and management systems. This study submits a new systemic management approach for water treatment systems based on the current scientific and technological development of intelligent instrumentation and field networks. Therefore, this study intends to contribute to the operational optimization of water treatment systems since a more powerful automation platform will enable the implementation of more strict and efficient control algorithms.
87

Filtração de água com diferentes concentrações de argila e silte em filtros de discos para irrigação localizada / Filtration of water with different clay and silts concentrations in discs filters for trickle irrigation

Oliveira, Cleomar Ferreira de 07 April 2010 (has links)
O uso da irrigação localizada está em pleno crescimento no Brasil, em decorrência da escassez de recursos hídricos e a necessidade de poupar água na irrigação. Isto tem requerido aplicação de conhecimentos no desenvolvimento de materiais e equipamentos que tendem a otimizar os sistemas de irrigação localizada. Os sistemas de irrigação localizada requerem obrigatoriamente sistemas de filtração para um tratamento de água. Os filtros são fundamentais à qualidade de água utilizada na agricultura irrigada, promovendo melhor desempenho dos sistemas de irrigação e seus componentes. Considerou para esta pesquisa o sistema de filtração que é fundamental em projetos de irrigação localizada, onde os emissores têm orifícios de dimensões reduzidas e ficariam obstruídos com o uso de água sem filtração adequada. Os ensaios foram realizados no Laboratório de Irrigação do Departamento de Engenharia de Biossistemas, da Escola Superior de Agricultura Luiz de Queiroz - ESALQ/USP, Campus de Piracicaba - SP. O experimento foi conduzido em duas etapas: na primeira, fez-se a caracterização hidráulica das equações de perdas de carga em função da vazão circulante nos filtros de discos 1 polegada mesh 120 e 155, utilizando água limpa e com auxilio das equações definiu-se duas vazões para realizar os ensaios de filtração: (a) vazão denominada ideal, correspondente à recomendada pelo fabricante, e (b) metade da vazão ideal. Na segunda etapa com auxílio das equações da perda de carga em função da vazão, analisou-se o desempenho do processo de filtração em função do tempo (240 minutos), utilizando três concentrações de sólidos em suspensão de argila e silte diluída em água nas seguintes proporções (1,0, 1,5 e 2,0) g L-1, mantendo-se a vazão constante durante o processo de filtração. Nesta etapa avaliou-se o processo de filtração, porcentagem de material retido, perda de carga e a quantidade de material retido. Considerando as condições em que a pesquisa foi realizada e com base nos resultados obtidos, conclui-se: o filtro de mesh 155 mostrou-se superior ao filtro de mesh 120 na remoção de sólidos em suspensão; a evolução da perda de carga nos filtros de mesh 155 foi mais rápida que nos filtros de mesh 120 devido ao maior acúmulo do material sólido em sua superfície, decorrência direta do diâmetro do orifício do elemento filtrante. / The use of the trickle irrigation is growing in Brazil, in consequence of the shortage of waters resources and the need to save irrigation water. This has been requesting knowledge application to development of equipments to optimize the trickle irrigation systems. Trickle irrigations systems always require filtration systems for a basic water treatment. The filters are fundamental for the water quality used in irrigated farming, providing better performance of irrigation systems and theirs components. It considered for this research the filtration system that is fundamental in project of trickle irrigation. The emitters have holes of reduced dimensions and they would be obstructed with the use of water without appropriate filtration. The trials were carried out in the Irrigation Laboratory of the Biosystems Engineering Department of the ESALQ/USP, Piracicaba SP. The experiment had two stages: the first, it was made the hydraulic characterization of the head loss equations according to the free flow in discs filter 1 inch mesh 120 and 155, using clean water and this head loss equations two flow was defined to accomplish the filtrations rehearsals:(a) ideal flow, is that recommended by the manufacturer,(b) half of the ideal flow. In the second way using the head loss equations according to the flow, the acting of the filtration process was analyzed according to the time (240 minutes), using clay and silts concentrations in the proportions of 1,0; 1,5 and 2,0 g L-1 diluted in water, keeping constant flow during the filtrations process. In this second stage it was evaluated the filtration process, percentage of retained material, head loss and the amount of retained material. Considering the obtained results, it follows that: the filter of mesh 155 was superior than to the filter of mesh 120 to remove of solids of water, the evolution of the head loss in the filters of mesh 155 was faster than the filters of mesh 120 due to the largest accumulation of the solid material in its surface, direct consequence of the holes diameter of the filtration element.
88

Tratamento de água para abastecimento público por sistema de separação por membrana de ultrafiltração: estudo de caso na ETA Alto da Boa Vista (São Paulo, SP). / Drinking water treatment by ultrafiltration: case study at Alto da Boa Vista WTP(São Paulo- SP).

Oliveira, Thiago Forteza de 28 April 2010 (has links)
Os processos de separação por membranas, especialmente a microfiltração e a ultrafiltração, são tecnologias emergentes para o tratamento de águas de abastecimento pela possibilidade de obtenção de águas com melhor qualidade em estações de tratamento mais compactas, de fácil automação, com menor geração de lodo e custo competitivo em relação ao sistema convencional de tratamento. A presente pesquisa avaliou o desempenho do processo de ultrafiltração no tratamento de água na ETA Alto da Boa Vista, que se utiliza do processo convencional tratando água do Reservatório Guarapiranga, manancial degradado da Região Metropolitana de São Paulo, sob os pontos de vista do desempenho operacional de produção de água e remoção de contaminantes. Tendo como água bruta, a água decantada da ETA ABV, o sistema operou por 2995 horas e 40 minutos, de agosto de 2009 a janeiro de 2010, produzindo com fluxo médio normalizado de 24,3 ± 2,2 L.h-1.m-2, pressão transmembrana de 94,2 ± 6,6 kPa e recuperação de 90,6 ± 0,9%. Foram analisados 13 pares de amostras de alimentação e permeado que indicaram a rejeição de COT de 11,2±8,6% (permeado=2,18±0,20 mg.L-1) , cor aparente 57,5±15,4% (permeado=2±2 mg.L-1 Pt- Co), condutividade elétrica 2,2±1,3% (permeado=138,2±17,8 S.cm-1), turbidez 92,7±4,5% (permeado=0,040±0,010 uT) e substâncias com absorção de radiação UV em 254nm 19,7±8,2% (permeado=0,025±0,008 cm-1). Em uma única amostra analisada, a rejeição a coliformes totais foi de 100%. Não foram detectados coliformes termotolerantes. Em 22/01/2010 foram coletadas amostras de alimentação e permeado para análise segundo Portaria 518 do Ministério da Saúde que indicou rejeição da contagem de bactérias heterotróficas de 98,98%, fluoretos de 36,49%, trihalometanos totais de 30,91%, alumínio total de 100%, cloretos de 20,29%, manganês total de 14,29% e sódio total de 0,81%. Em comparação com a água de abastecimento produzida na ETA ABV, a água do permeado da ultrafiltração apresentou qualidade melhor especialmente em relação à turbidez. / Membrane processes, specially microfiltration and ultrafiltration, are emerging technologies for drinking water treatment due the possibility for producing high quality water through compact treatment plants that are easier to automate with reduced sludge production and cost competitive compared with conventional processes. In this research it had been evaluated the ultrafiltration performance for water treatment at Alto da Boa Vista Water Treatment Plant that runs with conventional process, in São Paulo Metropolitan Region, from the viewpoints of water production and contaminants removal. An UF pilot plant was operated during 2995 hours and 40 minutes from August 2009 to January 2010 treating water from sedimentation tanks outlet. The UF pilot plant was able to operate with normalized flux of 24,3 ± 2,2 L.h- 1.m-2, transmembrane pressure of 94,2 ± 6,6 kPa and water recovery of 90,6 ± 0,9%. A total of 13 pairs of samples from feed and permeate were analyzed. The results were TOC rejection of 11,2±8,6% (permeate=2,18±0,20 mg.L-1), apparent color of 57,5±15,4% (permeate=2±2 mg.L-1 Pt-Co), conductivity of 2,2±1,3% (permeate=138,2±17,8 S.cm-1), turbidity 92,7±4,5% (permeate=0,040±0,01 uT) and UV 254nm 19,7±8,2% (permeate=0,025±0,008 cm-1). In an unique sample analysed for total coliforms, the rejection was 100%. Faecal coliforms were not detected in this sample. A sample of feed and permeate was collected at 01/22/2010 for analyses according to Portaria 518 (Brazilian drinking water regulations) that resulted in heterotrophic bacteria rejection of 98,98%, fluoride of 36,49%, total THM of 30,91%, total aluminium of 100%, chloride of 20,29%, total manganese of 14,29% and total sodium of 0,81%. In comparison with drinking water produced at Alto da Boa Vista WTP, the permeate of UF pilot plant was better in quality specially in terms of turbidity.
89

Montagem e caracterização de unidade de eletrodiálise em escala de laboratório para tratamento de soluções salinas. / Assembly and characterization of unit electrodialysis in laboratory scale for treatment of saline solutions.

Galuchi, Thales Pires Dias 06 August 2010 (has links)
A escassez de água nos grandes centros urbanos deve se agravar nos próximos anos. Novas fontes de água são necessárias para suprir a demanda. Nas cidades não há disponibilidade de terrenos para construção de estações de tratamento de águas e esgotos convencionais. Por isso, são necessários novos processos de tratamento. Processos de separação por membranas como osmose reversa e eletrodiálise são usados na dessalinização de águas e efluentes. Para a realização do estudo foi montada unidade de eletrodiálise em escala de laboratório. Na montagem selecionaram-se equipamentos que fossem resistentes à salinidade das soluções. As bombas magnéticas deveriam, ainda, superar a perda de cargas causada pelas membranas. As membranas foram adquiridas no exterior; os equipamentos, no mercado local. Os experimentos foram realizados em duas etapas: exploratória e comparativa. Eles seguiram os planejamentos de fatorial e do tipo Doehlert, respectivamente. Estudou-se a dessalinização de soluções aquosas unitárias (NaCl, Na2SO4, MgCl2 e KCl), com salinidade similar à água marinha (3,5%). Obtiveram-se como respostas os fluxos de sal, de água e consumo de energia em função dos fatores envolvidos no processo. Análises estatísticas propiciaram relacionar os fatores estudados com os resultados empíricos. Os fluxos salinos são proporcionais às densidade de corrente aplicadas e não apresentaram diferenças significativas entre si. Observou-se que o fluxo de água é relevante pelo mecanismo de solvatação de íons removidos e pela osmose. O consumo de energia é proporcional à densidade de corrente e maior para os sais bivalentes. / Water shortage in urban centers is expected to get worse in the next years. New water sources are necessary to meet demand. At urban area there are no available lands to build conventional water and sewage treatment plants. Therefore, new treatment processes are needed. Membrane processes like reverse osmosis and electrodialysis are used in water and wastewater desalination. A lab-scale electrodialysis unit was assembled for the study, based on a stack of electrodialysis membranes and support components that are capable of resisting solution salinity. The membrane stack was imported; the other equipment, obtained locally. The experiments were divided in two phases: exploratory and comparative. The experiments followed factorial and Doehlert designs, respectively. The desalination of aqueous solutions containing different inorganic salts (NaCl, Na2SO4, MgCl2 e KCl) in seawater salinity (3.5% mass) was studied. The responses were the salt and water fluxes and energy consumption in function of the processes variables selected. By means of a statistical analysis, it was possible to obtain the correlations for the studied factors based on the experimental results. The salt fluxes are proportional to the applied current density and they are not significantly different for the salts included in the study. It was observed that the water fluxes are relevant due to solvation of removed ions and osmosis. The energy consumption is proportional to current density and is larger for bivalent salts.
90

Seleção de tecnologias de tratamento de água para pequenas e médias comunidades brasileiras considerando aspectos ambientais / Technologies selection for drinking water treatment for small and medium brazilian communities considering environmental aspects

Jaqueline Akiko Sakamoto 27 August 2013 (has links)
As estações de tratamento de água - ETAs são fundamentais para a melhoria do saneamento ambiental de um país. No Brasil, a avaliação dos impactos ambientais negativos em ETAs se limita normalmente aos resíduos gerados no tratamento da água. As alterações ambientais decorrentes da construção e operação são desconsideradas na escolha das tecnologias, fato que podem prejudicar o alcance da sustentabilidade ambiental. O trabalho desenvolveu um método baseado na adaptação do Método Battelle-Columbus visando a seleção das tecnologias de tratamento de água e dos seus resíduos conforme o critério de impacto ambiental mínimo. O método é válido para comunidades brasileiras de pequeno e médio porte, as quais podem ser beneficiadas com vazões de projeto das ETAs entre 10 L/s e 100 L/s. As combinações dos processos e operações de tratamento nas ETAs e estações de tratamento dos resíduos- ETRs- para cinco diferentes vazões de projeto (10, 20, 40, 70 e 100 L/s) possibilitaram a avaliação de 205 projetos - 180 projetos extraídos de Sabogal Paz (2007; 2010) e 25 elaborados nesta pesquisa com o filtro ascendente em areia grossa na ETA de dupla filtração (DF2). Apenas os impactos ambientais negativos foram considerados na avaliação ambiental. A estimativa da magnitude de cada aspecto ambiental foi baseada nos quantitativos referentes à construção (requerimentos de área, concreto, chapa de aço, meio filtrante e camada suporte) e operação (consumo de energia elétrica e produtos químicos, geração de resíduos líquidos e sólidos) das ETAs e ETRs. Os resultados foram condizentes com a literatura, pois as ETAs menos robustas apresentaram um menor potencial de degradação e as tecnologias com maior área de implantação e consumo de energia elétrica foram mais impactantes. De fácil interpretação, o método é uma ferramenta que auxilia na tomada de decisão das ETAs a serem instaladas nos municípios brasileiros e que contribui para a mudança na abordagem normalmente adotada na seleção das tecnologias de tratamento de água. Com a questão ambiental como parte integrante do processo de escolha, uma visão mais abrangente e sustentável é alcançada para o setor de saneamento no país. / The water treatment plants (WTPs) are fundamental for the improvement of the environmental sanitation in a country. In Brazil, the negative environmental impacts assessment is usually limited in to the sludge produced in water treatment processes. Environmental impacts that occur during construction and operation of water treatment plants are not considered in the selection of technologies, what might prejudice the achievement of environmental sustainability. This research has developed a method based on the adaptation of the Method Battelle-Columbus to select the technologies for water treatment and sludge, according to the minimum environmental impact criteria. The method is effective for small and medium Brazilian communities of the country that can benefit with project flows that uses project flows of WTP between 10 and 100 L/s. Combinations of treatment processes and operations in WTPs and in waste treatment plants, for five different project flows (10, 20, 40, 70 and 100 L/s) enabled the evaluation of 205 projects- 180 projects according to Sabogal Paz (2007, 2010) and 25 projects were elaborated in this research with coarse sand upflow filter on the WTP of double filtration (DF2). Only the negative environmental impacts have been considered in the environmental assessment. The estimation of the magnitude of each environmental aspect was based on quantitative concerning the construction (area requirements, concrete, steel, filter media and support layer) and operation (electric energy consumption and chemicals, liquid and solid residue generation) of WTPs and waste treatment plants. The results were consistent with the literature because the less robust WTPs had a lower potential of degradation and the technologies with greater implantation area and electric energy consumption were more impactful. Easy to be interpreted, the method is a tool that can assist in decision making of WTPs to be installed in Brazilian municipalities and contributes to the change in the approach usually adopted in the technologies selection. On the integration of environmental issues as part of the selection process, a more comprehensive and sustainable solution is achieved to the sanitation sector in the country.

Page generated in 0.1194 seconds