• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • Tagged with
  • 56
  • 56
  • 50
  • 43
  • 17
  • 16
  • 15
  • 13
  • 12
  • 12
  • 11
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do tratamento de superfície por sonoquímica na resistência de união entre zirconia tetragonal policristalina estabilizada por ítria e cimento resinoso / Evaluation of surface treatment by sonochemical the bond strength between Yttria-Stabilized Tetragonal Zirconia Polycrystals and resin cement

Zens, Marlyni Aparecida 09 June 2015 (has links)
O objetivo deste estudo foi avaliar o efeito do tratamento ultrassônico como tratamento de superfície da zircônia tetragonal policristalina estabilizada por ítria (YTZP) e depois da sinterização final, por meio de mensuração da rugosidade superficial e teste de resistência adesiva por microsisalhamento. Para tanto, discos de Y-TZP foram confeccionados e distribuídos em 4 grupos (n=7), conforme o tratamento de superfície: 1-PRE: sonicação pré-sinterização; 2-POS: sonicação póssinterização; 3-JAT: jateamento com partículas óxido de alumínio 50μm; 4-CON: sem tratamento. Os espécimes foram polidos e padronizados e posteriormente submetidos aos tratamentos de acordo com cada grupo. Os grupos POS, JAT e COM foram sinterizados previamente ao tratamento e o grupo PRE após a sonicação. Os grupos PRE e POS foram submetidos a tratamento em processador ultrassonico (Sonics VCX-750) em potência nominal de 30% durante 15 minutos. O grupo JAT foi jateado com partículas de alumínio 50μm a uma distância de 15 cm, enquanto o grupo CON não recebeu nenhum tratamento. A mensuração de rugosidade superficial média (Ra) foi feita em Microscópio Confocal (MC), em seguida cilindros de cimento resinoso foram preparados e fotoativados na superfície do Y-TZP para serem submetidos ao ensaio mecânico de microcisalhamento realizado em máquina de ensaios universal (INSTRON). Os valores de rugosidade superficial e resistência de união obtidos foram submetidos a ANOVA a um critério e teste de Tukey. Quanto aos valores de rugosidade superficial, o grupo PRE (299,91 Mpa) e POS (291,23 Mpa) não apresentaram diferença estatística significante e o grupo JAT (925,21 Mpa) mostrou maiores valores de rugosidade superficial quando comparado ao PRE e POS. Para o teste de microcisalhamento não foram observadas diferenças estatisticamente significantes entre os grupos. Por meio dos resultados obtidos foi possível observar que o tratamento ultrassonico é capaz de alterar a superfície da Y-TZP e influenciar na resistência adesiva ao cimento resinoso. / The objective of this study was to evaluate the effect of ultrasonic treatment as surface treatment of Y-TZP before and after the final sintering, through measurement of surface roughness and bond strength by microshear test. Therefore, Y-TZP discs were made and distributed in 4 groups (n = 7), as surface treatment: 1-PRE: Presintering sonication; 2-POS: Post-sintering sonication; 3-JAT: air abrasion with aluminum oxide particles 50μm; 4-CON: no treatment. The specimens were polished and standardized and subsequently submitted to the treatments according to each group. The POS, JAT and CON groups been previously sintered to treatment and the PRE group after sonication. The PRE and POS groups were submitted to Ultrasonic Processor treatment (Sonics VCX-750) at 30% power for 15 minutes. The JAT group received air abrasion with aluminum particles 50μm at distance of 15 cm, while group received no treatment. The measurement of surface roughness was made in Confocal Microscope (MC), then resin cement cylinders were prepared and polymerized in Y-TZP surface to be subjected to mechanical testing microshear performed on universal testing machine (INSTRON). The values of surface roughness and bond strength were subjected to ANOVA and Tukey testAbout the values of surface roughness, the PRE group (299.91 MPa) and POS (291.23 MPa) showed no statistically significant difference and the JAT group (925.21 MPa) showed higher surface roughness values when compared to PRE and POS. For icroshear test statistically significant differences were observed between the groups. Through the results it was observed that the ultrasonic treatment is able to change the surface of the Y-TZP and influence the bond strength to resin cement.
2

Avaliação do tratamento de superfície por sonoquímica na resistência de união entre zirconia tetragonal policristalina estabilizada por ítria e cimento resinoso / Evaluation of surface treatment by sonochemical the bond strength between Yttria-Stabilized Tetragonal Zirconia Polycrystals and resin cement

Marlyni Aparecida Zens 09 June 2015 (has links)
O objetivo deste estudo foi avaliar o efeito do tratamento ultrassônico como tratamento de superfície da zircônia tetragonal policristalina estabilizada por ítria (YTZP) e depois da sinterização final, por meio de mensuração da rugosidade superficial e teste de resistência adesiva por microsisalhamento. Para tanto, discos de Y-TZP foram confeccionados e distribuídos em 4 grupos (n=7), conforme o tratamento de superfície: 1-PRE: sonicação pré-sinterização; 2-POS: sonicação póssinterização; 3-JAT: jateamento com partículas óxido de alumínio 50μm; 4-CON: sem tratamento. Os espécimes foram polidos e padronizados e posteriormente submetidos aos tratamentos de acordo com cada grupo. Os grupos POS, JAT e COM foram sinterizados previamente ao tratamento e o grupo PRE após a sonicação. Os grupos PRE e POS foram submetidos a tratamento em processador ultrassonico (Sonics VCX-750) em potência nominal de 30% durante 15 minutos. O grupo JAT foi jateado com partículas de alumínio 50μm a uma distância de 15 cm, enquanto o grupo CON não recebeu nenhum tratamento. A mensuração de rugosidade superficial média (Ra) foi feita em Microscópio Confocal (MC), em seguida cilindros de cimento resinoso foram preparados e fotoativados na superfície do Y-TZP para serem submetidos ao ensaio mecânico de microcisalhamento realizado em máquina de ensaios universal (INSTRON). Os valores de rugosidade superficial e resistência de união obtidos foram submetidos a ANOVA a um critério e teste de Tukey. Quanto aos valores de rugosidade superficial, o grupo PRE (299,91 Mpa) e POS (291,23 Mpa) não apresentaram diferença estatística significante e o grupo JAT (925,21 Mpa) mostrou maiores valores de rugosidade superficial quando comparado ao PRE e POS. Para o teste de microcisalhamento não foram observadas diferenças estatisticamente significantes entre os grupos. Por meio dos resultados obtidos foi possível observar que o tratamento ultrassonico é capaz de alterar a superfície da Y-TZP e influenciar na resistência adesiva ao cimento resinoso. / The objective of this study was to evaluate the effect of ultrasonic treatment as surface treatment of Y-TZP before and after the final sintering, through measurement of surface roughness and bond strength by microshear test. Therefore, Y-TZP discs were made and distributed in 4 groups (n = 7), as surface treatment: 1-PRE: Presintering sonication; 2-POS: Post-sintering sonication; 3-JAT: air abrasion with aluminum oxide particles 50μm; 4-CON: no treatment. The specimens were polished and standardized and subsequently submitted to the treatments according to each group. The POS, JAT and CON groups been previously sintered to treatment and the PRE group after sonication. The PRE and POS groups were submitted to Ultrasonic Processor treatment (Sonics VCX-750) at 30% power for 15 minutes. The JAT group received air abrasion with aluminum particles 50μm at distance of 15 cm, while group received no treatment. The measurement of surface roughness was made in Confocal Microscope (MC), then resin cement cylinders were prepared and polymerized in Y-TZP surface to be subjected to mechanical testing microshear performed on universal testing machine (INSTRON). The values of surface roughness and bond strength were subjected to ANOVA and Tukey testAbout the values of surface roughness, the PRE group (299.91 MPa) and POS (291.23 MPa) showed no statistically significant difference and the JAT group (925.21 MPa) showed higher surface roughness values when compared to PRE and POS. For icroshear test statistically significant differences were observed between the groups. Through the results it was observed that the ultrasonic treatment is able to change the surface of the Y-TZP and influence the bond strength to resin cement.
3

Avaliação da resposta do tecido ósseo tipo IV a implantes osseointegráveis de titânio com diferentes tratamentos de superfície / Evaluation of type IV bone tissue response to titanium implants with different surface treatments.

Freitas, Gileade Pereira 26 June 2014 (has links)
As alterações de superfície dos implantes de titânio (Ti) influenciam funções celulares e formação de tecido adjacente aos mesmos, mas é controverso se tais alterações trariam vantagens quando esses implantes fossem colocados em tecido ósseo de baixa qualidade. O objetivo deste estudo foi avaliar a resposta do tecido ósseo de baixa qualidade (tipo IV) a implantes de Ti com diferentes tratamentos de superfície. Para isso, implantes de Ti com superfície nanotexturizada (Ti-Nano), microtexturizada (Ti-Porous) e sem tratamento de superfície (Ti-Usinado) foram implantados em tíbias de coelhos. Após duas e seis semanas, o tecido ósseo formado ao redor dos implantes foi avaliado em cortes histológicos por desgaste e histomorfometricamente foram avaliados: a porcentagem de contato ossoimplante (BIC), porcentagem de área de osso mineralizado formado entre as espiras do implante (BABT), porcentagem da área de osso formada na área espelho (BAMA). Vários outros parâmetros morfométricos foram avaliados a partir de imagens e reconstruções tridimensionais obtidos por microtomografia. Ao final de seis semanas, foi avaliado o torque de remoção. Os resultados foram submetidos à análise de variância (ANOVA) com dois fatores de variação (tratamento de superfície e tempo de implantação) seguido do teste de Tukey (p≤0,05). Apesar de algumas diferenças estatisticamente significantes para alguns dos parâmetros morfométricos, tais diferenças não são biologicamente importantes para que pudessem ser atribuídas aos tratamentos de superfície. Tanto que, histologicamente não se observou diferença nos padrões de formação óssea ou tipo de osso formado que pudesse ser associado aos tratamentos de superfície e o torque de remoção também não foi afetado pelos tratamentos. Em conclusão, esses resultados mostraram que os tratamentos de superfície, embora sejam na escala micrométrica ou nanométrica, não induzem repostas do tecido ósseo tipo IV diferentes daquelas induzidas por superfícies sem tratamento. / Some alterations in titanium (Ti) implant surfaces influence cell functions and tissue formation in areas adjacent to the implants, but it is controversial whether these changes would bring advantages when these implants were placed in bone of poor quality. The aim of this study was to evaluate the response of poor quality bone tissue (type IV) to Ti implants with different surface treatments. For this, Ti implants with nanotextured surface (Ti-Nano), microtextured (Ti-Porous) and without surface treatment (Ti-Machined) were implanted into tibias of rabbits. After two and six weeks, the bone tissue around the implants was assessed in undecalcified histological sections and histomorphometrical analysis to evaluate: the percentage of bone-implant contact (BIC), percentage of the area of mineralized bone formed between threads (BABT), the percentage area of bone formed in the mirror area (BAMA). Several other morphometric parameters were evaluated from images and three-dimensional reconstructions obtained by microtomography. At the end of six weeks the removal torque was evaluated. The results were subjected to analysis of variance (ANOVA) with two factors of variation (surface treatment and time) followed by Tukey test (p≤0.05). Despite some statistically significant differences for some of the morphometric parameters, such differences are not biologically important and they could not be attributed to the surface treatments. In keeping with this, histological analysis failed to show any difference in bone formation that could be associated to the surface treatments and removal torque was not affected by treatments either. In conclusion, these results showed that the surface treatments, irrespective of being on the micrometer or nanometer scale, do not induce responses of type IV bone tissue different from those induced by untreated surfaces.
4

Estudo comparativo da resistência à corrosão em meio ácido e em meio contendo cloreto dos aços inoxidáveis UNS S44400, UNS S30403 e UNS S31603, obtidos por laminação a quente. / Corrosion resistance in acid and chloride environment for hot rolled stainless steels UNS S44400, UNS S30403, UNS S31603.

Botton, Tatiana 03 June 2008 (has links)
O presente trabalho tem como objetivo caracterizar o aco inoxidavel ferritico UNS S44400 quanto a sua resistencia a corrosao em comparacao a dois acos inoxidaveis austeniticos UNS S30403 e S31603, utilizando ensaios de perda de massa e eletroquimicos, tanto em meio acido quanto em meio contendo cloreto. A utilizacao dos inoxidaveis ferriticos vem crescendo em detrimento da utilizacao dos austeniticos tanto no Brasil, quanto no mundo, principalmente devido ao cenario instavel do preco do Ni. Sendo assim, cada vez mais se torna necessaria a obtencao de argumentos tecnicos e cientificos que permitam comparar diferencas entre as duas familias, mostrando suas vantagens e desvantagens. Os metodos utilizados para a avaliacao da resistencia a corrosao generalizada foram perda de massa (apos imersao) e polarizacao potenciodinamica em 0,5M H2SO4. A resistencia a corrosao por pite foi estudada atraves de polarizacao potenciodinamica ciclica em 3,5%NaCl. No caso especifico dos meios contendo cloreto, alem de se estudar os materiais com acabamento de lixa #600, obtido em laboratorio, optou-se por um estudo mais detalhado em funcao do acabamento superficial obtido em usina. Os acabamentos examinados foram: (i) material recozido, decapado em Usina e lixado em laboratório (até lixa #600) - (LL); (ii) material recozido e decapado em Usina - (RD); e (iii) material recozido, decapado em Usina, tratado termicamente em laboratório e lixado (até lixa #600) - (SL). Em meio acido, os acos austeniticos nao apresentaram corrosao, enquanto o ferritico apresentou uma taxa de corrosao constante de 0,0146 mg.cm-2.min-1 (8,4x10-4 A.cm-2) para imersoes ate 24h. Pela aplicacao do metodo de extrapolacao do trecho linear de Tafel foi obtido valor similar de densidade de corrente, de 4,57x10-4 A.cm-2, ou seja possuem a mesma ordem de grandeza. Diferentemente dos resultados obtidos em meio acido, nos ensaios de resistencia a corrosao em meio contendo cloreto, o aco UNS S44400 apresentou potencial de pite superior (em 3,5%NaCl) ao UNS S30403 e valores muito proximos ao do aco UNS S31603, para todas as condicoes de acabamento superficial examinadas. Alem disso, foi observado um relevante efeito das condicoes de tratamento termico de solubilizacao dos materiais: o tratamento de solubilizacao realizado em laboratorio aumentou o potencial de pite. Os resultados de potencial de pite medio - Ep - obtidos antes do tratamento termico foram: 77mVAg/AgCl para o UNS S44400, 43mVAg/AgCl para o UNS S30403 e 345mVAg/AgCl para o UNS S31603, sendo que apos solubilizacao o Ep medio foi de: 336mVAg/AgCl; 294mVAg/AgCl e 374mVAg/AgCl, respectivamente. Por sua vez, ha diferenca de desempenho quando aplicados os diferentes acabamentos superficiais. Com relacao ao acabamento proveniente de Usina, ou seja, recozido e decapado (RD), foi o que resultou em melhor desempenho. Apesar da media resultante alta para o acabamento RD, a dispersao dos resultados tambem foi alta. Comparando-se os acos UNS S44400 e UNS S31603, recozidos e decapados o 444 teve um potencial de pite de (500 + 173)mVAg/AgCl, e o aco 316 apresentou (568 + 167)mVAg/AgCl. Nota-se, portanto, que quando a aplicacao exige resistencia a corrosao em meio contendo ion cloreto, o aco 444 pode substituir o 316L. / The main reason of this work is the characterization of the ferritic stainless steel UNS44400 regarding its corrosion resistance when compared to two austenitic steels, UNS 30403 and UNS31603, using loss of weight and electrochemical tests, in acid and chloride environments. The application of ferritic stainless steel is increasing, both in the Brazilian an international market, especially because of the nickel cost instability. So, more information is necessary regarding each kind of material, allowing the comparison of these two families showing their advantages and disadvantages in different applications. For that reason, the main purpose of this work is the characterization of the corrosion resistance of a ferritic stainless steel, UNS S44400, comparing it with two austenitic stainless steels, UNS S30403 and S31603. Weight loss and electrochemical tests were conducted in acid or chloride environments. The general corrosion resistance was analyzed through weight loss measurements and electrochemical polarization in 0,5M H2SO4. The pitting corrosion resistance was studied through polarization in 3,5%NaCl. For the tests in chloride environment, it was done a study comparing laboratory and mill finishing proceducts: annealed and pickled and wet sand in laboratory - (LL); annealed and pickled - (RD); annealed and pickled, heat treated in laboratory and wet sand in laboratory - (SL). In acid environment, the austenitic stainless steel did not show weight loss, while the ferritic had a constant corrosion rate of 0,0146 mg.cm-2.min-1 (8,4x10-4. A.cm-2) until 24 hours of immersion. This result was confirmed by the extrapolation of linear portion of the polarization curves (Tafel method), whose current density was 4,57x10-4 A.cm-2. In chloride environment, the UNS S44400 steel showed higher pitting potential in 3,5%NaCl compared to UNS S30403 and similar results for all finishes when compared with UNS S31603. Besides, it was observed that the heat treatment that was done in laboratory raised pitting potential. The pitting potential results were: before heat treatment, 77mVAg/AgCl for UNS S44400, 43mVECS, for UNS S30403 and 345mVAg/AgCl for UNS S31603; and after heat treatment they were: 336mVAg/AgCl; 294mVAg/AgC; and 374mVAg/AgCl, respectively. The annealed and pickled material that was tested directly from the Mill (RD) presented the highest pitting potential showing the importance of pickling process. Comparing the annealed and pickled UNS S44400 steel with UNS S31603, the mean pitting potential was (500 + 173)mVAg/AgCl and (568 + 167)mVAg/AgCl respectively, and considering the deviation of the tests, it was proved that it is possible to apply both UNS S44400 or UNS S31603 when a high pit corrosion resistance is required.
5

Influência do tratamento da superfície interna da cerâmica sob diferentes parâmetros de irradiação com laser de Er,Cr:YSGG / Influence of the treatment of the internal surface of the ceramic on different parameters of laser irradiation Er,Cr:YSGG

Inca, Hector Eduardo Cepeda 06 November 2018 (has links)
Objetivos: Este estudo teve como objetivo avaliar a resistência de união entre cimento resinoso e as amostras de zircônia irradiadas como o laser de Er,Cr:YSGG em quatro parâmetros. Foram utilizadas 78 unidades experimentais (12,4 mm x 7,6 mm x 1,6 mm) a partir de blocos de Y-TZP (zircônia tetragonal estabilizada com ítrio) pré-sinterizados. A fim de obter superfícies padronizadas, os espécimes foram lixados com uma sequência decrescente de lixas (600, 1200, 1500). Em seguida, os blocos foram sinterizados em um forno específico, de acordo com as recomendações do fabricante. Os grupos experimentais foram compostos a partir de um fator de variação - tratamento de superfície. Foram formados 6 grupos experimentais (n=13) Controle, sem tratamento de superfície, grupo Rocatec, com tratamento triboquímico (Rocatec System Plus 3M ESPE), e 4 grupos laser (Waterlase Iplus Biolase Inc. Irvine, CA, EUA comprimento de onda 2780nm, 700?s, de 50% de ar e 50% de água, ponta MZ6 600?m): L3W 20Hz (53,57J/cm2), grupo L3W 50Hz (21,43J/cm2), grupo L6W 20Hz (107,14J/cm2), grupo L6W 50Hz (42,68J/cm2). Um espécime de cada grupo foi analisado através de microscopia eletrônica de varredura MEV (10000x). Após dos tratamentos de superfície, em cada bloco de zircônia foram colados 6 cilindros de resina usando cimento dual contendo MDP (Panavia F 2.0). Todas as amostras foram armazenadas em água destilada a 37ºC. O teste de microcisalhamento foi feito na máquina de ensaio universal (Instron 5565 EUA). Três dos 6 tubos colados em cada bloco foram avaliados depois de 24 horas de armazenamento em água a 37ºC e os 3 restantes foram avaliados depois de 2000 ciclos térmicos (5ºC - 30ºC). O tipo de falha foi determinado através de estereomicroscópio. Os dados foram analisados pelos testes de análise de variância (ANOVA) e de Tukey com um nivel de significância de p<0,01. Resultados: O grupo controle positivo (ROCATEC) apresentou diferença significativa (p <0,001) com os demais grupos. Quando foi simulado o envelhecimento térmico (termociclagem), todos os grupos apresentaram diferença significativa (p <0,001) na resistência de união comparada com o protocolo sem termociclagem. O tratamento de superfície convencional ainda é preconizado como uma alternativa válida para melhorar a resistência de união na zircônia. O uso de laser de Er,Cr:YSGG com uma largura de pulso de 700?s dentro dos parâmetros estudados não promoveu mudanças na superfície de zircônia que favorecessem a adesão com cimento resinoso. A termociclagem influenciou negativamente em todos os grupos experimentais. / This study aimed to evaluate the bond strength between resin cement and the irradiated zirconia samples a the Er, Cr: YSGG laser in four parameters. It was used 78 experimental units (12.4mm x 7.6mm x 1.6mm) from pre-sintered Y-TZP (Ytriumstabilized Tetragonal Zirconia) blocks. In order to obtain standardized surfaces the specimens were sanded with a decreasing sanding sequence (600,1200,1500). Then, the blocks form sintered in a specific oven, according to the manufacturer\'s recommendations. The experimental groups were composed of a variation factor - the surface treatment. Thus, 6 experimental groups were formed (n=13). Control, without surface treatment, the Rocatec group, with triboquimic treatment (Rocatec System Plus 3M ESPE), and 4 laser groups (Waterlase Iplus Biolase Inc. Irvine, CA USA wavelength 2780nm, 700?s, 50% air and 50% water, MZ6 600?m tip): L3W 20Hz (53.57J / cm2), L3W 50Hz group (21.43J / cm2), L6W 20Hz group (107.14J / cm2), group L6W 50Hz (42.68J / cm2). One specimen from each group was analyzed by Scanning Electron Microscopy (10000x). After the surface treatments, 6 resin cylinders were bonded to each zirconia block using dual cement containing MDP (Panavia F 2.0). All samples were stored in distilled water at 37 ° C. The micro-shear test was performed on the universal test machine (Instron 5565 USA). 3 of the 6 tubes pasted in each block were evaluated after 24 hours of storage in 37 ° C water and the remaining 3 were evaluated after 2000 thermal cycles (5 ° C - 30 ° C). The type of failure was determined by stereomicroscope. The data were analyzed by a test for analysis of variance (ANOVA) and tukey with a significance level of p <0.01. Results: The positive control group (ROCATEC), evaluated immediately after cementation, showed a better bond strength and there was no significant difference when thermal aging was simulated (thermocycling), nor did it differ significantly from the groups without thermocycling of 3w20Hz or 6w50hz. Conventional surface treatment is still advocated as a valid alternative to improve bond strength in zirconia. The use of Er, Cr: YSGG laser with a pulse width of 700?s within the studied parameters did not promote changes in the zirconia surface that favored adhesion with resin cement. Thermocycling influenced negatively all experimental groups.
6

Avaliações histológica e histomorfométrica de implantes osseointegráveis de titânio com superfície anodizada e revestida por Ca e P / Histological and Histomorphometric analysis of Ti implants with surfaces modified by anodic spark deposition in Ca and P

Albuquerque, Gustavo Cavalcanti de 20 December 2010 (has links)
Estudos de modificações de superfície de implantes de Ti têm atraído a atenção dos pesquisadores por existir grande interesse em tratamentos que possam acelerar o processo fisiológico de reparo do tecido ósseo em contato com o Ti. Avaliações in vitro mostraram que superfícies de Ti obtidas por modificação físicoquímica como a anodização (anodic spark discharge ASD) podem representar uma boa alternativa para melhorar a osseointegração de implantes. O objetivo deste estudo foi avaliar a resposta do tecido ósseo de mandíbula de cães a implantes osseointegráveis de Ti com superfície modificada por duplo ataque ácido (AE), por anodização em solução de íons cálcio e fosfato (ASD-AK) e anodização em solução de silício, cálcio e fosfato seguido por ataque alcalino em NaOH (SiB-Na). Para isso dez cães foram submetidos a exodontia dos pré-molares 12 semanas antes das instalação dos implantes. Os animais foram sacrificados no período de 5 e 8 semanas (cinco por período) e os segmentos ósseos contendo os implantes foram processados. Foram avaliados os efeitos dos tratamentos de superfície na (1) porcentagem de contato direto osso-implante, (2) formação óssea entre as roscas do implante e (3) formação óssea à distância da superfície do implante. Os resultados mostraram que todos os tratamentos (AE, ASD-AK e SiB-Na) permitiram formação óssea em contato direto e adjacente à superfície de Ti sem apresentar nenhum diferença qualitativa e quantitativa no padrão de reparo ósseo. Portanto, esses tratamentos deveriam ser avaliados clinicamente na reabilitação implanto-suportada de pacientes parcial ou totalmente edêntulos. / Surface modification of Ti have been attracted the attention of the researchers for existing great interest in treatments that can speed up the physiological process of repair of the bone contact. Aiming to improve the osseointegration of Ti implants several surface treatments have been proposed including those obtained by anodic spark deposition technique (anodic spark discharge ASD). This treatment allows to developing a thin and porous surface layer enriched with selected ions from the electrochemical solution. This study was designed to analyze bone repair adjacent to and in contact with Ti implants with surfaces modified by acid etching (AE) and anodic spark deposition (ASD). Surface modification of Ti implants was carried out by three methods: AE, ASD in calcium and phosphate solution (ASD-AK), and ASD in calcium, phosphate and silicon solution followed by alkali etching in NaOH (SiB-Na). Ten mongrel dogs were submitted to premolar extraction and after 12 weeks AE, BS, and SiB-Na self-screw Ti implants were placed into edentulous areas. Animals were killed at 3 and 8 weeks (five per period) and bone fragments with implants harvested and processed to obtain thin ground sections. Histomorphometric analysis was carried out to determine the bone-implant contact (BIC), bone area between threads (BABT), and bone area adjacent to threads (BAAT). The results had shown that all the treatments (AE, ASD-AK and SiB-Na) had allowed bone formation in direct and adjacent contact to the surface, without qualitative and quantitative difference in the standard of bone repair. Therefore, these surface treatments would have clinically to be evaluated in the implant-supported rehabilitation of total edentulous or patients partial.
7

Eficiência dos conjuntos óticos de alumínio especular de alto desempenho energético / Efficiency of optical specular aluminium assemblies of high energy performance

Bigoni, Silvia 10 May 2013 (has links)
Este trabalho tem por finalidade indicar uma metodologia de avaliação das perdas progressivas de iluminâncias, de intensidades luminosas e de rendimentos que ocorrem nos conjuntos óticos com distintos tratamentos de superfícies dos alumínios, utilizados na produção de luminárias comerciais com lâmpadas fluorescentes tubulares. Alguns critérios foram relacionados como imprescindíveis para a obtenção de resultados representativos, sendo o parâmetro geográfico o primeiro deles. Para isso, foram indicadas três instalações onde o critério de escolha eram os agentes atmosféricos externos, de elevada, média ou menor poluição ambiental. O segundo foi a escolha de \"luminárias de ensaios\", com conjuntos óticos em alumínios especulares de diferentes características e propriedades de reflexão. O último critério foi o temporal, com medições fotométricas praticadas em laboratório e em campo. Foram adotadas para análise e comparação as medições fotométricas de três conjuntos óticos de referência (refletor e aleta), bem como luminárias de ensaio de campo em dois períodos para análise da depreciação dos conjuntos óticos, que totalizaram uma média de 2.700 h. Como resultado desta análise, foram feitas considerações que demonstram que padrões de alumínio de menor ou maior rendimento, com capacidade reflexiva entre 75% e 95%, apresentam perdas luminosas consideráveis, e que podem causar divergência entre o projetado pelos profissionais de iluminação e o executado. / This work aims to specify a methodology for evaluating the progressive loss of illuminance, luminous intensity and performance, which occur in the optical assemblies of commercial fixtures with fluorescent lamps, whose aluminium received different types of surface treatment. In order to obtain representative results, some criteria were listed as essential, being the geographic parameter the first one. For this, we chose three facilities using as a criterion of choice the external atmospheric agents of high, medium or low environmental pollution. The second was the choice of \"test fixtures\" with optical assemblies made of specular aluminium with different reflection characteristics and properties. The last criterion was the time lapse, with photometric measurements practiced in laboratory and in the field. For analysis and comparison, we took photometric measurements of three optical sets used as reference (reflector and fin) and field test fixtures in two different periods for depreciation analysis of their optical assemblies, which reached an average of 2700 hours. As a result, considerations have been made demonstrating that Aluminium patterns of higher or lower performance with reflective capacity between 75% and 95%, show considerable light loss, and that this can cause divergence between what is the projected by the lighting professionals and what is effectively executed.
8

Influência de diferentes protocolos de cimentação na resistência de união em cerâmicas com diferentes composições

Campos, Veridiana Silva 19 February 2018 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-05-21T18:28:19Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Veridiana Campos.pdf: 1599980 bytes, checksum: dc566e6e595eb2ee2afd4a74f9ee9f2a (MD5) / Made available in DSpace on 2018-05-21T18:28:19Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Veridiana Campos.pdf: 1599980 bytes, checksum: dc566e6e595eb2ee2afd4a74f9ee9f2a (MD5) Previous issue date: 2018-02-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O objetivo desse trabalho in vitro foi avaliar a resistência de união ao microcisalhamento (μSBS) de cerâmicas com diferentes graus de translucidez e agentes de cimentação, no tempo imediato e após simulação de 1 ano de envelhecimento em termociclagem, assim como avaliar a composição elementar por espectrometria de energia dispersiva (EDS). Foram selecionadas 4 cerâmicas: Dissilicato de lítio (DL), Prettau Anterior (PA), Prettau (PR) e ICE (IC). Os espécimes cerâmicos foram distribuídos em 16 grupos experimentais (n=5) a depender da combinação de variáveis: cerâmica vs tratamento de superfície (silano- SL ou silano+adesivo- AS) vs tempo de armazenamento (imediato e longevidade) vs cimento resinoso (Variolink II ou Variolink Veneer). As cerâmicas de zircônia foram submetidas ao jateamento com óxido de alumínio e a cerâmica de dissilicato de lítio foi condicionada com ácido fluorídrico à 5% por 20s. Realizado o tratamento de superfície de acordo com cada grupo experimental, tubos de tygon foram posicionados na superfície da cerâmica e preenchidos com cimento resinoso. Após 24 horas em estufa à 37ºC e após 10.000 ciclos térmicos, os espécimes foram submetidos ao teste de microcisalhamento, numa velocidade de 1mm/min até a falha. As falhas foram observadas em microscópio óptico num aumento de 100x, e avaliadas em microscopia eletrônica de varredura (FEG) com uma magnificação de 150x. Adicionalmente, as cerâmicas foram submetidas ao teste de espectrometria de energia dispersiva (EDS) para avaliação da sua composição elementar. Para fins estatísticos, optou-se por dividir os resultados em duas condições experimentais: uma para o cimento Variolink II e outra para o Veneer. Portanto, para cada cimento os dados da μSBS foram submetidos ao teste de μSBS (ANOVA 3-fatores e Tukey, α = 0,05). Para o cimento Variolink II, não foi encontrada interação tripla significativa (p>0,05). A interação dupla tratamento vs tempo (p<0,001) foi significativa, sendo os valores de μSBS imediato estatisticamente superiores à longevidade. Já a interação dupla tratamento vs cerâmica, foi estatisticamente significante (p=0,039), sendo que as cerâmicas à base de zircônia tiveram maiores valores de resistência de união, independente do tratamento de superfície. E a interação dupla tempo vs cerâmica (p<0,001) mostrou uma diminuição da μSBS de todas as cerâmicas após a termociclagem. O cimento Variolink Veneer mostrou uma interação tripla significativa (p<0,001) para todos os grupos. Independente do tratamento de superfície e da cerâmica, estatisticamente os maiores valores de resistência de união foram encontrados no tempo imediato, e as cerâmicas à base de zircônia apresentaram valores estatisticamente superiores ao dissilicato de lítio. Pode-se concluir que as cerâmicas de zircônia são mais resistentes ao microcisalhamento, no tempo imediato e após termociclagem; e que a associação AS interfere positivamente nos resultados à longo prazo. / The objective of this in vitro work was to evaluate a micro-shear strength (μSBS) of ceramics with different degrees of translucency and cementing agents,on immediate time and after simulation of 1 year of aging in thermocycling, as well as to evaluate the elemental composition do to the dispersive energy spectrometry (EDS) test. Four ceramics were selected: Lithium Dissilicate (DL), Prettau Anterior (PA), Prettau (PR) and ICE (CI). The ceramic specimens were distributed in 16 experimental groups (n = 5) depending on the combination of variables: ceramic vs. surface treatment (silane-SL or silane + adhesive-AS) vs. storage time (immediate and longevity) vs. resin cement Brochure Variolink II or Variolink). The zirconia ceramics were subjected to blasting with aluminum oxide and the lithium disilicate ceramic with fluoridric acid 5% per 20s. After the surface treatment according to each experimental group, tygon tubes were placed on the ceramic surface and filled with resin cement. After 24 hours in an oven at 37ºC and after 10.000 thermal cycles, the specimens were submitted to the micro-shear test at a speed of 1mm / min until failure. Failures were observed in optical microscope in an increase of 100x, and evaluated in Scanning Electron Microscopy (FEG) with a magnification of 150x. Additionally, ceramics were submitted to the dispersive energy spectrometry (EDS) test to evaluate their elemental composition. For statistical purposes, it was chosen to divide the results into two experimental conditions:: one for Variolink II cement and another for Veneer. Thus, for each cement the μSBS data were subjected to the μSBS test (ANOVA 3-factor and Tukey, α = 0.05). For Variolink II cement, no significant triple interaction was found (p> 0.05). The double treatment vs time interaction (p <0.001) was significant, with immediate μSBS statistically higher values to distance. On the other hand, the double treatment versus ceramic interaction was statistically significant (p = 0.039), and the ceramics based on zirconia had higher values of bond strength, regardless of surface treatment. And the double time vs. ceramic interaction (p <0.001) showed a decrease of μSBS for all ceramics after the thermocycling. Variolink Veneer cement showed a significant triple interaction (p <0.001) for all groups. Regardless the surface treatment and ceramics, statistically, the highest values of resistance were found in the immediate time, and ceramics based on zirconia presented statistically higher values than lithium disilicate. It can be concluded that zirconia ceramics are more resistant to micro-shearing, on immediate time and after thermocycling; and that the AS association interferes positively with long-term results.
9

Efeitos de Superfícies de Contorno na Orientação de Cristais Líquidos Liotrópicos / Boundary Surface Effects on the Liotropic Liquid Crystal Orientation

Bechtold, Ivan Helmuth 19 May 2000 (has links)
Para uso em aplicações tecnológicas os cristais líquidos são geralmente confinados em em celas, onde a interação do cristal líquido com a superfície de contorno é de grande importância para o bom desempenho do dispositivo. Os cristais líquidos liotrópicos em particular, possuem propriedades físicas muito mais complexas que os termotrópicos, que não são conhecidas em sua totalidade. Dessa forma, desenvolvemos um estudo com o objetivo de investigar a influência da superfície na configuração de uma amostra de cristal líquido liotrópico. Utilizamos alguns tratamentos de superfície para alterar as condições de contorno e investigar a orientação induzida ao cristal líquido. Esses tratamentos alteram as propriedades físico-químicas das superfícies, tais como o caráter hidrofílico (utilizando lâminas de vidro) e hidrofóbico (utilizando lâminas de vidro recobertas com polímero). Outro tratamento empregado consiste no esfregamento dos substratos ao longo de uma direção preferencial que pode alterar a topografia das superfícies. Variamos a espessura da amostra para comparar os efeitos devido as interações da superfície em relação as interações entre as moléculas no volume. Efetuamos análise de textura da amostra de cristal líquido liotrópico após colocada nas celas fabricadas com os substratos tratados. Através de medidas de transmitância de um feixe de luz polarizada pela amostra, investigamos os processos dinâmicos de reorientação e relaxação induzidos por um campo magnético externo. / The use of liquid crystals (LC) in technological applications (LC displays) implies that these materials might be confined in thin cells, where the interactions with the boundary surfaces are of great importance for a good performance of such displays. The physical properties of lyotropic liquid crystals, in particular, are much more complexe than those of thermotropic LC, and are not up to now completely understood. Therefore, we have performed a study with the objective of investigating the influence of the boundary surface on the configuration of a lyotropic liquid crystal sample. Different surface treatments were used to modify the boundary conditions and to investigate the orientation induced to the liquid crystal. These surface treatments may affect the physico-chemical properties of the surfaces, such as the hydrophilicity (using clean glass plates) and hydrophobicity (by coating the glass plates with a polymer). Another treatment that have been used is the unidirectional rubbing of the substrates that can change the surfaces topography. The sample thickness was also varied in order to compare the effects due to surface interactions with respect to the intermolecular interactions in the bulk. We have performed an analysis of the texture of the lyotropic liquid crystal sample once confined in the cells built from the treated substrates. By means of the measurements of the intensity of a polarized light beam crossing the sample, we have investigated the dynamics of the reorientation and relaxation processes induced by the an external magnetic field.
10

Comparação  das propriedades das superfícies da poliamida 6.6 tratada por plasma e por radiação ionizante / Comparison of the properties polyamide 6.6 surfaces treated by plasma and by ionizing radiation

Irineu, Rosa Maria da Silva 17 December 2010 (has links)
Este trabalho tem por objetivo a comparação das propriedades da superfície da poliamida 6.6 tratada por plasma e por radiação ionizante, assim como determinar qual a melhor técnica e condição para ativação da superfície, visando a adesão da mesma e borracha poliacrílica utilizada na fabricação de retentores automotivos. O tratamento da poliamida 6.6 por plasma foi realizado utilizando um equipamento Electronic DIENER Plasma Surface- Technology LFG40, com gás nitrogênio à pressão de 1,40 kg/cm2. As amostras de poliamida 6.6 também foram tratadas por radiação ionizante, à pressão atmosférica e em vácuo, utilizando um acelerador industrial de elétrons, Dynamitron JOB 188, com dose de radiação de 5, 10, 20, 40, 50, 100, 200, 300, 400 e 500kGy com taxa de dose de 11,22 kGy/s para todas as doses e taxa de 11,22 kGy/s e 22,38 kGy/s para a dose de 20kGy. Após os processos de modificação da superfície da poliamida 6.6, parte das amostras não tratadas, tratadas por plasma e por radiação ionizante foram incorporadas à borracha poliacrílica, e outra parte foi destinada a caracterização da superfície utilizando as técnicas de MEV/EDS, FT-IR, PIXE/RBS, AFM e ângulo de contato. As amostras não tratadas e as amostras irradiadas não aderiram à borracha poliacrílica. As amostras tratadas por plasma aderiram à borracha poliacrílica com eficiência e apresentaram diferenças de rugosidade, nas análises de MEV e AFM, e aumento no ângulo de contato quando comparado com as amostras não tratadas. As amostras irradiadas não apresentaram diferenças significativas de propriedades nas análises utilizadas neste trabalho, quando comparadas com as amostras não tratadas. A radiação ionizante não foi eficiente na modificação da superfície da poliamida 6.6 para aderência à borracha poliacrílica. / This study aims to compare the surface properties of polyamide 6.6 plasma treatment and ionizing radiation, as well as determine the best technique and condition of the surface activation, adhesion of the same order and polyacrylic rubber used in manufacturing of automotive retainers. Treatment of polyamide 6.6 plasma was performed using an equipment \"Electronic Diener - Plasma - Surface-Technology LFG40\" with nitrogen gas at a pressure of 1.40 kg/cm2. Samples of polyamide 6.6 were also treated with ionizing radiation, atmospheric pressure and in vacuum, using an industrial electron accelerator, Dynamitron JOB 188 with radiation dose of 5, 10, 20, 40, 50, 100, 200, 300, 400 and 500kGy with a dose rate of 11.22 kGy/s for all doses and rate of 11.22 kGy/s and 22.38 kGy/s for a dose of 20kGy. After the processes of surface modification of polyamide 6.6, part of the untreated samples, treated by plasma and by ionizing radiation were incorporated into the polyacrylic rubber, and another part was designed to characterize the surface using the techniques of SEM / EDS, FT- IR, PIXE / RBS, AFM and contact angle. Untreated samples and the irradiated samples did not join the polyacrylic rubber. The samples treated by plasma joined the polyacrylic rubber efficiently and showed differences in roughness in SEM and AFM, and an increase in contact angle when compared with untreated samples. The irradiated samples showed no significant differences in the analysis of properties used in this study when compared with untreated samples. Ionizing radiation was not effective in surface modification of polyamide 6.6 for adherence with polyacrylic rubber.

Page generated in 0.1294 seconds