Spelling suggestions: "subject:"tratamento dde água notável"" "subject:"tratamento dee água notável""
1 |
Remoção do ácido 2,4 diclorofenoxiacético (2,4-D) por adsorção em carvão ativado pulverizado associado ao tratamento convencional de água para consumo humano / Removal of acid 2,4-dichlorophenoxyacetic (2,4-D) in powdered activated carbon adsorption associated with conventional drinking water treatmentLeal, Waldiléia Pereira 05 July 2013 (has links)
Made available in DSpace on 2016-12-23T14:04:29Z (GMT). No. of bitstreams: 1
Waldileia Pereira Leal.pdf: 3453316 bytes, checksum: 63c0a56552f4b09c97956f4c0d9f711c (MD5)
Previous issue date: 2013-07-05 / O 2,4-D é o segundo herbicida mais utilizado no Brasil, podendo chegar à água de abastecimento público. Devido à limitação do tratamento convencional na remoção de microcontaminantes e a capacidade do carvão ativado em removê-los, este estudo investigou a aplicação de carvão ativado pulverizado (CAP) na remoção do 2,4-D por processos de adsorção associado ao tratamento convencional utilizando água bruta do Rio Santa Maria da Vitória em equipamentos de jartest. Os diagramas de coagulação foram construídos através de estudo de tratabilidade de água utilizando o sulfato de alumínio e o policloreto de alumínio como coagulantes. Foram realizados ensaios de adsorção com carvões derivados da casca de coco (CAP 1) e de pinnus (CAP 2) que foram caracterizados e avaliados na sua capacidade de remover o 2,4-D. A remoção de matéria orgânica natural também foi determinada pela medição de carbono orgânico dissolvido (COD) e absorvância UV 254 nm. Para a quantificação e detecção dos analitos, ácidos 2,4-D, 2,4,5-T e o 2,4-DCP, foi desenvolvida e validada uma metodologia analítica em cromatografia líquida de alta eficiência (CLAE). Através dos dados de adsorção obtidos, o CAP 1 apresentou maior capacidade de remoção do 2,4-D e foi associado ao tratamento convencional, sendo adicionado quinze minutos antes, um minuto antes e um minuto após a adição do sulfato de alumínio. Os resultados indicaram que a adição do coagulante não influenciou na capacidade de adsorção do CAP 1 que apresentou-se eficiente na remoção do herbicida, atendendo ao padrão de potabilidade de água vigente / The 2,4-D is the second most widely used herbicide in Brazil, reaching the public water supply. Due to the limitation of conventional treatment in removing micro-contaminants and capacity of activated carbon to remove them, this study investigated the application of powdered activated carbon (PAC) in the removal of 2,4-D in adsorption process associated with conventional treatment using raw water from the Rio Santa Maria da Vitória in equipment jartest. The diagrams of coagulation were constructed through treatability study of water using aluminum sulfate and polyaluminum chloride as coagulants. Tests of adsorption with carbons derived from coconut shells (PAC 1) and pinus (PAC 2) were characterized and evaluated in its ability to remove 2,4-D. The removal of natural organic matter was also determined by measuring the dissolved organic carbon (DOC) and UV absorbance at 254 nm. To detection and quantification of analytes, acids 2,4-D, 2,4,5-T and 2,4-DCP an analytical methodology for high performance liquid chromatography (HPLC/DAD) was developed and validated. Through the adsorption data, the PAC 1 showed greater capacity for removal of 2,4-D and was associated with conventional treatment, fifteen minutes prior, one minute prior to or one minute after the addition of the aluminum sulfate. The results indicated that the addition of coagulant had no effect on adsorption capacity of the PAC 1 which showed to be being effective for the removal of herbicide, given the drinking water quality standards force
|
2 |
Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable waterMeca, Karen Soraia 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
|
3 |
Influência do tempo de detenção hidráulica e do gradiente médio de velocidade na zona de contato no desempenho de unidade piloto de flotação por ar dissolvido aplicado à clarificação de água para abastecimento / Influence of hydraulic detention time and velocity gradient in the contact zone on the performance of unit pilot dissolved air flotation clarification applied to potable waterKaren Soraia Meca 03 October 2014 (has links)
O desempenho de unidades de flotação por ar dissolvido (FAD) depende significativamente do projeto da zona de contato (ZC) dessas unidades, situada na entrada das mesmas e responsável por promover condições adequadas para que ocorram taxas satisfatórias de colisão entre as microbolhas de ar e os flocos formados na etapa antecedente de floculação da água para abastecimento. Os dois principais parâmetros de projeto da ZC são o tempo de detenção hidráulico ou tempo de contato (Tzc) e o gradiente médio de velocidade na ZC (Gzc). A presente dissertação apresenta os resultados de estudo sobre a influência do Tzc e do Gzc na ZC de uma unidade piloto de flotação por ar dissolvido (UPFAD) com escoamento contínuo aplicada ao tratamento de água para abastecimento. Foram utilizados módulos contendo tela metálica em seu interior com malha de #25 mm com diferentes dimensões, de modo a se obterem diferentes valores de Gzc e Tzc. Foram investigadas duas configurações na unidade de FAD (Configurações A e B), nas quais o comprimento (Lzc) e a altura (Hzc) da ZC foram variados, permitindo a alteração do Tzc e mantendo-se controlados os valores de Gzc (com a introdução ou não de diferentes módulos de tela metálica na ZC) e vice versa. Os demais parâmetros do processo de FAD não sofreram variações, tais como taxa de aplicação superficial (TAS) na zona de separação, tempo de floculação, entre outros. Para a configuração A, foram estudadas três alturas diferentes na ZC e para a configuração B, quatro alturas diferentes na ZC, o que acarretou, para cada valor de Gzc variação do Tzc. Para cada configuração da ZC, também foram testados três valores de vazão de recirculação de água saturada com ar de modo a se obterem três diferentes concentrações de ar (A/V) no processo de flotação. Para todos os parâmetros analisados (Turbidez, Cor, Absorbância), as maiores eficiências de remoção foram obtidas nos ensaios realizados com o uso da tela #25 mm tanto na configuração A (TASzc = 136 m/h e G = 6,1 s-1) quanto na configuração B (TASzc = 87 m/h e G = 3,2 s-1). Os resultados permitem concluir que o par de valores (Tzc, Gzc) é mais apropriado para o projeto da zona de contato de unidades FAD do que o par (Tzc, TASzc) usualmente adotado pelos projetistas, sendo que, na faixa de valores investigados a UPFAD apresentou melhor desempenho para o par: Tzc de 41 s e Gzc de 6,1 s-1. / The performance of units dissolved air flotation (DAF) depend significantly of design on the contact zone (CZ) of these units, situated at the entrance thereof and responsible for promoting appropriate conditions to occur satisfactory collision rates between air microbubbles and the flocs formed in the step of flocculation of potable water. The two main design parameters of the CZ are the hydraulic detention time or contact time (Tcz) and the velocity gradient in the CZ (Gcz). This work presents the results of study of the effects of varying the Tcz and Gcz at the contact zone of pilot unit DAF with continuous flow applied to the treatment of potable water. Were used modules containing metal grille with mesh of #25 mm, with different dimensions in order to obtain different values of Gcz and Tcz. Were investigated two configurations in the unit FAD ( configurations A and B) where the length (Lcz) and height (Hcz) of contact zone were varied, allowing the variation of Tzc and keeping the values of Gcz controlled (with the introduction or not of different modules in the metal grille in CZ) and vice versa, without changes in other process variables FAD, such as rate of surface application (TAS) in the separation zone, flocculation time, among others. For the configuration A were studied three different heights in the CZ and in configuration B, four different heights in the CZ, which resulted, for each value of Gcz (relative to the chosen value of Lcz) the variation of Tzc. For each configuration of CZ were also tested three values of recirculation flow of air saturated in order to obtain three different values of concentration in air (A/V) in the flotation process. For all parameters analyzed (turbidity, color, absorbance), the highest efficiencies were obtained in assays performed using the grille #25 mm, both in configuration A (TAScz = 136 m/h and L = 6,1 s-1) and configuration B (TAScz = 87 m/h and G = 3,2 s-1). The results indicate that the pair of values (Tcz, Gcz) is more suitable for project of the CZ of units FAD than the pair (Tcz, TAScz) usually adopted by the designers, and values in the range investigated in UPFAD showed performed better for Tcz of 41 s and Gcz of 6,1 s-1.
|
Page generated in 0.107 seconds