• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • Tagged with
  • 9
  • 9
  • 9
  • 6
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicação da análise de perigos e pontos críticos de controle no tratamento de água para consumo humano / Application of hazard analysis and critical control points to drinking water treatment

Oliveira, Daniel Cobucci de 22 March 2010 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2015-11-03T13:50:36Z No. of bitstreams: 1 texto completo.pdf: 5799471 bytes, checksum: 2011bc9ea678e0f76c7163f828014e87 (MD5) / Made available in DSpace on 2015-11-03T13:50:36Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5799471 bytes, checksum: 2011bc9ea678e0f76c7163f828014e87 (MD5) Previous issue date: 2010-03-22 / Este trabalho visa discutir a aplicação da metodologia de Análise de Perigos e Pontos Críticos de Controle em estações de tratamento de água para consumo humano, por meio de estudos de caso em estações de tratamento de água para consumo humano que operam com ciclo completo, quais sejam: ETA UFV - responsável pelo abastecimento de água do 'campus' da Universidade Federal de Viçosa e ETA SAAE I e II, responsáveis pelo abastecimento de água da área urbana do município de Viçosa - MG. A dissertação foi desenvolvida seguindo, basicamente, a sequência de passos para implantação do sistema APPCC, ou seja: (i) etapas preliminares; (ii) identificação de perigos; (iii) identificação de pontos críticos de controle; (iv) estabelecimento de limites críticos; (v) definição do monitoramento dos PCC; (vi) estabelecimento das medidas corretivas. Vale ressaltar que o presente trabalho restringe-se à avaliação de perigos microbiológicos. Como resultado foram identificados como perigos microbiológicos as bactérias, os vírus e os protozoários, que são os principais perigos presentes nos mananciais e estações de tratamento de água. Sendo que neste trabalho foram monitorados e detectados nos pontos de captação dos mananciais que abastecem os sistemas em estudo a presença de Giardia spp., Cryptosporidium spp., coliformes totais e Escherichia coli. Para identificação dos pontos críticos de controle foi aplicada a árvore de decisão proposta por Vieira 2005. Considerando os resultados obtidos e as diferenças entre o trabalho de Viera e este viu-se a necessidade de proposição de adaptações a arvore de decisão. Neste sentido foram incorporados os conceitos de pontos de atenção e pontos de controle, além dos tradicionais pontos críticos de controle. Com as adaptações na árvore de decisão foram identificados como: (i) PCC para o perigo protozoários as etapas de coagulação, floculação, decantação e filtração, demonstrando que as estações em estudo necessitam de adequações; (ii) PCC para o perigo bactérias/vírus a etapa de desinfecção, sendo as etapas que antecedem a desinfecção consideradas pontos de controle. Os limites críticos foram estabelecidos com base no padrão de potabilidade vigente. Foram estabelecidos também limites operacionais através da avaliação de desempenho das estações e banco de dados do monitoramento de rotina das mesmas. / The dissertation was developed by basically following the implementation steps of the HACCP system: (i) preliminary stages; (ii) hazard identification; (iii) identification of critical control points (CCP); (iv) establishment of critical limits; (v) establishment of critical control point monitoring; (vi) establishment of corrective measures. The scope of the present study is restricted to microbiological hazards. The microbiological hazards were identified as being bacteria, viruses, and protozoa, Which are the main hazards found in water sources and water treatment plants. The presence of Giardia spp., Cryptosporidium spp., total coliform and Escherichia coli were detected and monitored at the sources that feed the systems under investigation. In order to identify the critical control points, the decision tree proposed by Vieira 2005 was applied. Considering the results obtained and the differences between this study and Vieiraºs, adaptations to the decision tree were found necessary. As a result, in addition to the traditional critical control points, the concepts of attention points and control points were incorporated. With the adaptations to the decision tree, the following points were identified: (i) CCP for protozoa hazard were the coagulation, flocculation, decantation, and filtration stages; (ii) CCP for bacterial/viral hazards was the disinfection stage, While the stages preceding disinfection were considered as control points. The critical limits were established based on the current potability standards. Operational limits were also established through performance evaluations of the plants and the routine monitoring databases of these plants.
2

Biological treatment of pulp and paper mill effluents with aerobic granular sludge / Tratamento biológico de efluentes de fábrica de polpa celulósica e papel com lodo aeróbio granular

Morais, Ismarley Lage Horta 15 December 2016 (has links)
Submitted by Cleber Casali (clebercasali@ufv.br) on 2017-01-23T18:48:59Z No. of bitstreams: 1 texto completo.pdf: 971488 bytes, checksum: 19e0c0d9a60547273b821e1120b83e1b (MD5) / Made available in DSpace on 2017-01-23T18:48:59Z (GMT). No. of bitstreams: 1 texto completo.pdf: 971488 bytes, checksum: 19e0c0d9a60547273b821e1120b83e1b (MD5) Previous issue date: 2016-12-15 / O tratamento de águas residuárias com lodo aeróbio granular apresenta muitas vantagens em comparação ao processo convencional de lodos ativados com lodo floculento. Os grânulos são agregados microbianos densos e compactos que possibilitam uma maior retenção de biomassa no reator biológico e uma elevada capacidade de sedimentação, favorecendo a remoção biológica de matéria orgânica, nutrientes, compostos tóxicos e clarificação final do efluente devido à estrutura e propriedade de sedimentação do lodo. Estes benefícios resultaram em um aumento do interesse de implantação do processo de tratamento com lodo aeróbio granular e a busca de maiores informações à respeito da formação, estabilidade e a influência dos parâmetros operacionais sobre a granulação. Assim, este trabalho apresenta uma revisão bibliográfica com a compilação das informações recentes sobre o lodo aeróbio granular incluindo a possibilidade de utilização dos grânulos aeróbios em biorreatores a membrana, em elevadas temperaturas e as aplicações em plantas de tratamento de larga escala. Foi realizada, ainda, a avaliação da adição de 100 mg.L-1 e 200mg.L-1 de cálcio na estabilidade, resistência mecânica e diâmetro dos grânulos formados em reatores em batelada sequencial alimentados com efluente de uma fábrica de polpa celulósica kraft. Os reatores apresentaram eficiências similares de remoção de matéria orgânica e o diâmetro médio dos grânulos foi de cerca de 11 mm em todos os reatores, embora os grânulos formados no reator que recebeu 100 mg.L-1 de Ca2+ apresentou velocidade de sedimentação 36% superior aos demais e maior resistência mecânica. A melhoria da granulação pode ser obtida ainda pela seleção de microrganismos que contribuem para a formação dos agregados. A produção de substâncias poliméricas extracelulares (SPE) pelas bactérias é um dos fatores que influencia a agregação celular, uma vez que as SPE agem como agente cimentante e atuam na adesão entre as células. A produção de SPE de dezenove isolados microbianos, obtidos de grânulos aeróbios formados no tratamento de efluente de fábrica de papel reciclado foi avaliada e seis isolados dos gêneros Staphylococcus, Agrobacterium, Enterobacter e Rhodococcus melhoraram a granulação biológica. A ausência destes isolados nos testes de co-agregação reduziu a relação entre proteínas e polissacarídeos (relação PN/PS) e diminuiu a formação de agregados. / Aerobic granular sludge wastewater treatment has many advantages over the conventional activated sludge process. The granules are dense and compact microbial aggregates that allow a higher biomass retention in the biological reactor and a high settling velocity, favoring the biological removal of organic matter, nutrients, toxic substances and improves wastewater clarification. Due to the sludge structure and settleability, these benefits have attracted considerable interest in the implementation of the aerobic granular sludge process and givenrise to the need for better understanding of the formation, stability and influence of the operational parameters on the granulation. Thus, this work was divided into three chapters. Chapter 1 presents a review of recent developments on aerobic granular sludge including the possibility of using aerobic granules in membrane bioreactors, at high temperatures and for a full-scale implementation. The addition of divalent cations in the reactors can enhance granulation and granule stability. In Chapter 2, the effect of the addition of 100 mg.L-1 and 200 mg.L- of calcium in the stability, mechanical strength and diameter of the granules formed in sequential batch reactors (SBR) fed with pulp mill effluent was evaluated. The reactors showed similar organic matter removal efficiencies and granule size was approximately 11 mm in all SBR, although the granules formed in the reactor with addition of 100 mg.L- of Ca2+ had a settling velocity 36% higher and greater mechanical resistance than the others. Granulation can also be enhanced by the selection of microorganisms that contribute to the aggregates formation. Bacterial extracellular polymeric substances (EPS) production is one factor that contributes to cell aggregation, since EPS acts as an intercellular cement that may reinforce cohesion inside the bacterial clusters. In Chapter 3, EPS production of nineteen microbial isolates obtained from aerobic granules formed in the recycled paper wastewater treatment was evaluated and six isolates of the genera Staphylococcus, Agrobacterium, Enterobacter and Rhodococcus contributed to biological granulation. The absence of these isolates in the co-aggregation tests reduced the protein-polysaccharide ratio (PN / PS ratio) and reduced the aggregates formation.
3

Tratamento de esgoto urbano em reatores UASB com uso de microrganismos eficientes / Urban sewage treatment in UASB reactors with the use of effective microorganisms

França, Bruna Thomazinho 11 December 2018 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2019-02-25T11:12:15Z No. of bitstreams: 1 texto completo.pdf: 2065992 bytes, checksum: fc539640a5507d3ec970b1c692461946 (MD5) / Made available in DSpace on 2019-02-25T11:12:15Z (GMT). No. of bitstreams: 1 texto completo.pdf: 2065992 bytes, checksum: fc539640a5507d3ec970b1c692461946 (MD5) Previous issue date: 2018-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Microrganismos Eficientes constituem uma comunidade de indivíduos aeróbios e anaeróbios que desempenham funções benéficas ao meio ambiente e são capazes de se desenvolver em diversos ecossistemas. Neste trabalho, a técnica de Microrganismos Eficientes (EM Technology®) foi aplicada com o objetivo de verificar se esses organismos são capazes de conferir melhorias no tratamento de esgoto urbano. O aparato experimental foi constituído de dois reatores UASB de bancada e somente um foi inoculado com Microrganismos Eficientes. Os reatores operaram durante 90 dias com tempos de detenção hidráulica de 12, 9 e 6 horas e foram avaliadas as eficiências de remoção de matéria orgânica e nutriente, bem como o processo de granulação anaeróbia. A eficiência dos processos foi analisada em termos de remoção de DQO, DBO 5 e nitrogênio amoniacal enquanto que o processo de granulação foi examinado por meio de testes de resistência ao cisalhamento do grânulo e quantificação de EPS (substâncias poliméricas extracelulares). Análises de diversidade microbiana dos domínios Bacteria e Archaea foram realizadas com o intuito de avaliar se o inóculo provocou alterações nas comunidades dos reatores em termos de diversidade de espécies dentro do período operacional proposto. Os resultados apontam que o inóculo de Microrganismos Eficientes não foi capaz de provocar diferença (a 5% de significância) na eficiência de remoção de compostos orgânicos e nutrientes do sistema. Os testes de resistência ao cisalhamento dos grânulos e de quantificação de EPS apontam que a presença dos Microrganismos Eficientes gerou grânulos mais resistentes e com melhores propriedades de agregação. O inóculo de Microrganismos Eficientes apresentou elevada abundância e baixa diversidade de espécies se comparado às amostras de lodo analisadas. As espécies com maior abundância no inóculo não foram capazes de sobreviver dentro do reator no período proposto. A elevada abundância de Archaeas metanogênicas acetoclásticas nos dois reatores, indicou que esses organismos contribuíram para processo de granulação dos reatores e conseguiram completar o seu ciclo de reações, gerando um efluente tratado com baixa carga orgânica. / Effective Microorganisms are a community of aerobic and anaerobic individuous which performed beneficial functions for the environment and are capable of developing in various ecosystems. In this work, the Effective Microorganisms technique (EM Technology®) was applied in order to verify whether these organisms, widely used in agriculture, are capable of enhancing domestic wastewater treatment. Two UASB bench reactors were built and one was inoculated with Effective Microorganisms to evaluate the performance of the inoculum. The UASB reactors were operated at hydraulic retention times of 12, 9 and 6 hours for thirty days each (90 days total) during which treatment efficiency and anaerobic granulation were compared. Treatment efficiency was analyzed in terms of COD, BOD 5 and ammonium removals while granulation was examined by measuring granule shear strength and extracellular polymeric substances (EPS) contents. In order to evaluate the difference in microbial communities caused by the inoculum during the operational period, analyses of microbial richness and abundance of the domains Bacteria and Archaea were performed. Results showed that the inoculum of Effective Microorganisms did not affect (5% significance level) organic matter and nutrient removals. Granules shear strengh tests and EPS contents indicated that inoculation with Effective Microorganisms resulted in more resistent granules, with better agregation properties. The Effective Microorganisms inoculum presented a higher species abundance, but lower diversity when compared to sludge samples analysed. Moreover, the more abundant species in the inoculum were not capable of developing in the reactor during the operational period. The high abundance of acetotrophic metanogen Archaeas in both reactors, considering the total number of reads, indicated that these organisms contributed to the granulation process in the reators and were able to complete their reaction cycle, generating treated wastewater with low organic load.
4

Remoção de compostos biologicamente ativos em sistemas convencionais de tratamento de esgotos domésticos / Removal of biologically active compounds in conventional domestic wastewater treatment plants

Magalhães, Déborah Neide de 26 February 2016 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-06-06T13:30:10Z No. of bitstreams: 1 texto completo.pdf: 3420825 bytes, checksum: 01efcef37a91ed531386161c4808b5d1 (MD5) / Made available in DSpace on 2017-06-06T13:30:10Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3420825 bytes, checksum: 01efcef37a91ed531386161c4808b5d1 (MD5) Previous issue date: 2016-02-26 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / Os esgotos domésticos são misturas complexas que, mesmo após passar pelo tratamento biológico, ainda podem apresentar toxicidade e microcontaminantes em concentrações capazes de trazer prejuízos ao ambiente, sobretudo em locais onde não há legislação específica para esse caráter. A presente pesquisa teve por objetivos traçar um panorama dos estudos sobre toxicidade e microcontaminantes em esgotos sanitários realizados no Brasil e fazer um estudo em escala real, da remoção de compostos biologicamente ativos em três sistemas convencionais de tratamento de esgotos sanitários comumente empregados no país. O levantamento bibliográfico demonstrou que a remoção de toxicidade e microcontaminantes nas diversas tecnologias avaliadas é dependente de parâmetros estruturais e operacionais, sendo possível alcançar índices satisfatórios de remoção com a adequação desses parâmetros, com os lodos ativados apresentando os melhores resultados. Foi possível observar que a produção de dados no país ainda é bastante incipiente em muitas regiões, com as pesquisas estando mais concentradas nas regiões sudeste e sul. A avaliação de parâmetros físicos e químicos de três sistemas com diferentes tecnologias de tratamento: lodos ativados, UASB/filtro biológico percolador (FBP), tanque séptico/filtro anaeróbio) demonstrou que o tratamento aeróbio foi mais eficiente na remoção de matéria orgânica e nutrientes em relação aos outros dois sistemas, com eficiências de remoção de DQO acima de 90%, e até 70% nos outros dois. Quanto às toxicidades aguda e crônica aos organismos Daphnia similis e Ceriodaphnia dubia, os três sistemas foram capazes de reduzir ou remover os efeitos tóxicos, com o sistema de lodos ativados removendo de 87 a 100%. Nos sistemas anaeróbios, a toxicidade não foi completamente removida e efluente do sistema constituído de UASB/FBP foi o que apresentou potencial para causar toxicidade no corpo receptor. As amostras ainda foram submetidas a um protocolo de avaliação e identificação da toxicidade que revelou que os agentes tóxicos presentes são eliminados em pH ácido, com tratamentos adicionais que envolvam a volatilização ou oxidação. Com relação aos microcontaminantes, as amostras dos três sistemas foram submetidas ao ensaio YES (Yeast Estrogen Screen) para avaliação de atividade estrogênica e à análise cromatográfica por CG/EM para a identificação de compostos estrogênicos. Os resultados do ensaio YES revelaram que o sistema de lodos ativados foi o que apresentou melhor eficiência na remoção da estrogenicidade, com carga média afluente de 9,2 mg equivalentes de 17-β estradiol (EQ-E2)/dia, e efluente de 0,3 mg EQ-E2/dia. O sistema composto por UASB / FBP apresentou remoção mínima (1,8 e 1,5 ng EQ-E2/L, para entrada e saída, respectivamente) e o de tanque séptico/filtro anaeróbio registrou acréscimo da atividade estrogênica de 1,6 ng EQ-E2/L na entrada para 2,3 ng EQ-E2/L na saída, no período amostrado. Os resultados qualitativos das análises cromatográficas revelaram a detecção esporádica dos hormônios naturais estrona, 17-β estradiol e estradiol e o sintético 17-β-etinilestradiol nos três sistemas. Os alquilfenóis 4-octil e 4-nonilfenol foram raramente detectados, enquanto o bisfenol A foi o analito mais frequentemente detectado nas amostras. Foram detectados hormônios em amostras de sedimento do ponto de lançamento dos efluentes dos sistemas anaeróbios, os quais não estavam presentes nas amostras de sedimento a montante do lançamento, sugerindo a contribuição dos efluentes tratados nesses sistemas para a contaminação do sedimento. / Domestic wastewaters are complex mixtures that can still present toxicity and microcontaminants at concentrations capable of causing environmental harm even after biological treatment, especially where no specific discharge limits for such characteristics exists. The objectives of this research were to present a panorama of Brazilian studies on domestic wastewater toxicity and microcontaminant removal and to monitor removal of toxicity in three full-scale wastewater treatment plants that operate different, commonly used biological processes, over the course of a year. The literature review on Brazilian research demonstrated that toxicity and microcontaminant removal by the various technologies evaluated depends on system design and operational parameters and that satisfactory removal efficiencies can be achieved by properly adjusting these parameters, with the activated sludge process presenting the best results. It was also observed that research in this field is still quite incipient in many regions of Brazil, with most studies concentrated in the southern and southeastern states. Evaluation of physical and chemical parameters in the three full- scale systems - activated sludge (AS), UASB reactor-trickling filter (UASB/TF) and septic tank-anaerobic filter (ST/AF) – showed that the fully aerobic AS process was more efficient than the others in removing organic matter and nutrients, with COD removal over 90% for the AS system and up to 70% in the other two. All three systems were able to reduce or remove acute toxicity to Daphnia similis and chronic toxicity to Ceriodaphnia dubia, with 87-100% removal in the AS plant. Toxicity was not completely removed in the ST/AF and UASB/TF systems and the treated wastewater at the outlet of the latter presented potential to cause toxicity in the receiving water. Phase I toxicity identification evaluations were carried out on all toxic system inlet and outlet samples and it was found that toxicity was most consistently reduced or eliminated after aeration at acid pH, suggesting oxidation and, or volatilization of acidic substances as probable toxicity removal mechanisms, supporting the higher removal efficiency observed in the AS system. Samples from the three systems were analyzed using the yeast estrogen screen (YES) assay to evaluate estrogenic activity and by gas chromatography-mass spectrometry for detection of eight estrogenic compounds. YES test results revealed that the AS system presented the highest estrogenicity removal efficiencies, with average inlet and loads of 9.2 and 0.3 mg 17- β estradiol equivalents (E2 eq.)/d. The UASB/TF system presented minimal estrogenicity removal (average concentrations of 1.8 and 1.5 ng E2 eq./L for inlet and outlet samples, respectively), while the ST/AF system increased estrogenic activity, with average concentrations of 1.6 and 2,3 ng E2 eq./L for inlet and outlet samples, respectively, during the monitoring period. The natural hormones estrone, 17-β- estradiol, estriol and the synthetic 17-β-ethinylestradiol were sporadically detected in the three systems, while 4-octylphenol and 4-nonylphenol were rarely detected. Bisphenol A was the most frequently detected of the compounds evaluated. Hormones were detected in sediment samples downstream, but not upstream of the UASB/TF and ST/AF discharge pipes, suggesting that the treated wastewaters contributed to sediment contamination.
5

Efeito de algicidas sobre as cianobactérias e a microcistina-LR: implicações para o tratamento avançado de águas de abastecimento com carvão ativado / Effect of algaecides on cyanobacteria and microcystin-LR: implications for advanced drinking water treatment using activated carbon

Koshigoe, Amanda Sati Hirooka 14 May 2019 (has links)
Um grande desafio da atualidade é a crescente ocorrência, em ambientes aquáticos, de cianobactérias potencialmente tóxicas capazes de produzir cianotoxinas como a microcistina. Estratégias de controle de florações incluem a aplicação de algicidas. No entanto, esses produtos podem resultar na liberação de toxinas, que podem não ser removidas da água pelos processos convencionais de tratamento, sendo necessária uma etapa adicional como a adsorção com carvão ativado granular (CAG). A presente pesquisa avaliou com embasamento estatístico o efeito de cinco diferentes algicidas (à base de diuron, carbonato de sódio, polímero catiônico, sulfato de cobre e peróxido de hidrogênio), aplicados em três concentrações distintas, sobre a Microcystis aeruginosa, analisando-se a densidade celular, o biovolume, a concentração de potássio e de microcistina-LR extracelular/intracelular. Além disso, foram investigadas as implicações que esses produtos tiveram sobre a adsorção em dois CAGs, por meio de isotermas e modelos cinéticos. Todos os algicidas afetaram a integridade das células, resultando na liberação de microcistina. O último dia experimental (dia 7) foi o que apresentou maior concentração de microcistina extracelular, em que, em alguns casos, houve aumento de 10 vezes da concentração final de microcistina extracelular em relação à concentração inicial. O potencial de liberação de microcistina extracelular ocorreu na seguinte ordem de algicidas: polímero catiônico > sulfato de cobre > peróxido de hidrogênio > carbonato de sódio > diuron. Os algicidas também alteraram o comportamento de adsorção (de monocamada para multicamada), bem como pioraram os ajustes cinéticos. Além disso, enquanto o polímero catiônico praticamente triplicou a capacidade adsortiva dos carvões, o sulfato de cobre e o peróxido de hidrogênio pioraram o desempenho de ambos. Os algicidas possuem modos diferentes de ação e geraram consequências distintas para os indicadores avaliados, além de alterar a adsorção. Isso pode indicar a necessidade de se considerar a presença desses produtos na elaboração de projetos de estações de tratamento de água (ETAs). / A major challenge nowadays is the increasing occurrence in aquatic environments of potentially toxic cyanobacteria capable of producing cyanotoxins such as microcystin. Bloom control strategies include application of algaecides. However, these products may result in toxins release, which may not be removed from water by conventional treatment processes, requiring an additional step such as adsorption with granular activated carbon (GAC). The present study evaluated, using statistical methods, the effect of five different algaecides (diuron, sodium carbonate, cationic polymer, copper sulfate and hydrogen peroxide), applied on Microcystis aeruginosa in three different concentrations. We analyzed cell density, biovolume, potassium concentration and extracellular/intracellular microcystin-LR concentration. In addition, we investigated the implications these products had on two GACs adsorption, through isotherms and kinetic models. All algaecides affected cell integrity, resulting in microcystin release. The last experimental day (day 7) was the one that presented the highest extracellular microcystin concentration, in which, in some cases, there was a 10 times increase in the final extracellular microcystin concentration in relation to the initial concentration. The extracellular microcystin release potential occurred in the following order of algaecides: cationic polymer > copper sulfate > hydrogen peroxide > sodium carbonate > diuron. Algaecides also modified adsorption behavior (from monolayer to multilayer), as well as worsened kinetic adjustments. Furthermore, while cationic polymer almost tripled carbons adsorptive capacity, copper sulfate and hydrogen peroxide worsened the performance of both. Algaecides present different modes of action and caused distinct consequences for the evaluated indicator, besides modifying adsorption process. This may indicate the need to consider the presence of these products in water treatment plants (WTPs) designs.
6

Tratamento de efluentes líquidos na Estação Antártica Comandante Ferraz (EACF): avaliação da aplicabilidade do processo eletrolítico. / Treatment of wastewater in Ferraz Station (Brazil): evaluation of the applicability of the electrolytical process.

Carmen Josefa Miguelez Rodriguez 14 March 2008 (has links)
Esta pesquisa enfoca o uso do processo eletrolítico, como alternativa para tratamento de efluentes líquidos na Estação Antártica Comandante Ferraz (EACF), considerando as limitações ambientais locais e aspectos de consumo de energia. Este processo, classificado como não convencional, vem sendo estudado pela comunidade científica nacional e internacional para tratamento de diversos efluentes, inclusive esgotos domésticos, apresentando várias vantagens que estimularam a verificação de sua aplicabilidade para as condições peculiares da EACF. Foram realizados ensaios, em escala de laboratório, com esgotos domésticos coletados em um condomínio no Rio de Janeiro, usando reatores eletrolíticos com capacidade de 4 L, com eletrodos de desgaste de alumínio (Al) e de ferro (Fe), distância entre as placas de 0,9 cm e 1,8 cm, temperaturas na faixa de 7C a 22C, e ensaios para verificação da sua eficiência, por meio de parâmetros como DQO, DBO5, SST, turbidez e volume de lodo gerado. Sob temperatura de 15C e condições de condutividade da ordem de 900 S/cm, estimada para os esgotos da EACF, aplicando densidade de corrente de 22,9 A/m2, 4,5 V, tempo de retenção de 25 min, os resultados apresentaram valores de DQO no efluente tratado de 65 mg/L(redução de 89%), DBO de 56 mg/L (redução de 64 %), SST de 8 mg/L, com turbidez de 11,3 uT e, após filtração, turbidez de 3,2 uT, consumo de energia de 0,8 Wh/L. O aspecto é límpido e a qualidade final obtida é compatível para ser submetida a tratamento de desinfecção. A partir dos dados obtidos, foram avaliadas por meio de pré-projeto: a viabilidade de sua implantação em container, a estimativa de consumo de energia e de lodo gerado, requisitos de manutenção, operação, além da sugestão de monitoramentos e de medidas de mitigação de impactos ambientais associados à respectiva instalação. / This research focuses on the use of the electrolytical process as alternative for treatment of wastewater in Ferraz Station, considering the local environmental limitations, and aspects of consumption of energy. This process, classified as unconventional, has been studied by the national and international scientific community to treat several effluents, besides domestic sewage, presenting several advantages which stimulated the verification of its applicability in the peculiar conditions of Ferraz Station. Laboratory experiments, with domestic sewage collected in a condominium in Rio de Janeiro were accomplished using electrolytical reactors of 4 L, with electrodes of aluminum (Al) and of iron (Fe), distance between the plates of 0,9 cm and 1,8 cm, temperatures, in the strip from 7C to 22C, and analyses laboratories for verification of its efficiency through COD, BOD5, Suspended Solids, turbidity and generated sludge. Under temperature of 15C and conditions of conductivity of 900 S/cm, estimated for the station sewage, applying density of current of 22,9 A/m2, 4,5 V, time of retention of 25 min, the results presented values of COD in the treated effluent of 65 mg/L (reduction of 89%), BOD of 56 mg/L (reduction of 64%), Suspended Solids of 8 mg/L, with turbidity of 11,3 Tu and after filtration 3,2 Tu, consumption of energy of 0,8 Wh/L. Its appearance is very clean and the final result is compatible to be submitted to disinfection treatment. Based on the obtained data, the viability of its implantation in container, the estimate of consumption of energy and generated sludge and maintenance requirements, operation, besides the monitoring suggestion, and mitigating measures of environmental impacts were evaluated in a preliminary project.
7

Tratamento de efluentes líquidos na Estação Antártica Comandante Ferraz (EACF): avaliação da aplicabilidade do processo eletrolítico. / Treatment of wastewater in Ferraz Station (Brazil): evaluation of the applicability of the electrolytical process.

Carmen Josefa Miguelez Rodriguez 14 March 2008 (has links)
Esta pesquisa enfoca o uso do processo eletrolítico, como alternativa para tratamento de efluentes líquidos na Estação Antártica Comandante Ferraz (EACF), considerando as limitações ambientais locais e aspectos de consumo de energia. Este processo, classificado como não convencional, vem sendo estudado pela comunidade científica nacional e internacional para tratamento de diversos efluentes, inclusive esgotos domésticos, apresentando várias vantagens que estimularam a verificação de sua aplicabilidade para as condições peculiares da EACF. Foram realizados ensaios, em escala de laboratório, com esgotos domésticos coletados em um condomínio no Rio de Janeiro, usando reatores eletrolíticos com capacidade de 4 L, com eletrodos de desgaste de alumínio (Al) e de ferro (Fe), distância entre as placas de 0,9 cm e 1,8 cm, temperaturas na faixa de 7C a 22C, e ensaios para verificação da sua eficiência, por meio de parâmetros como DQO, DBO5, SST, turbidez e volume de lodo gerado. Sob temperatura de 15C e condições de condutividade da ordem de 900 S/cm, estimada para os esgotos da EACF, aplicando densidade de corrente de 22,9 A/m2, 4,5 V, tempo de retenção de 25 min, os resultados apresentaram valores de DQO no efluente tratado de 65 mg/L(redução de 89%), DBO de 56 mg/L (redução de 64 %), SST de 8 mg/L, com turbidez de 11,3 uT e, após filtração, turbidez de 3,2 uT, consumo de energia de 0,8 Wh/L. O aspecto é límpido e a qualidade final obtida é compatível para ser submetida a tratamento de desinfecção. A partir dos dados obtidos, foram avaliadas por meio de pré-projeto: a viabilidade de sua implantação em container, a estimativa de consumo de energia e de lodo gerado, requisitos de manutenção, operação, além da sugestão de monitoramentos e de medidas de mitigação de impactos ambientais associados à respectiva instalação. / This research focuses on the use of the electrolytical process as alternative for treatment of wastewater in Ferraz Station, considering the local environmental limitations, and aspects of consumption of energy. This process, classified as unconventional, has been studied by the national and international scientific community to treat several effluents, besides domestic sewage, presenting several advantages which stimulated the verification of its applicability in the peculiar conditions of Ferraz Station. Laboratory experiments, with domestic sewage collected in a condominium in Rio de Janeiro were accomplished using electrolytical reactors of 4 L, with electrodes of aluminum (Al) and of iron (Fe), distance between the plates of 0,9 cm and 1,8 cm, temperatures, in the strip from 7C to 22C, and analyses laboratories for verification of its efficiency through COD, BOD5, Suspended Solids, turbidity and generated sludge. Under temperature of 15C and conditions of conductivity of 900 S/cm, estimated for the station sewage, applying density of current of 22,9 A/m2, 4,5 V, time of retention of 25 min, the results presented values of COD in the treated effluent of 65 mg/L (reduction of 89%), BOD of 56 mg/L (reduction of 64%), Suspended Solids of 8 mg/L, with turbidity of 11,3 Tu and after filtration 3,2 Tu, consumption of energy of 0,8 Wh/L. Its appearance is very clean and the final result is compatible to be submitted to disinfection treatment. Based on the obtained data, the viability of its implantation in container, the estimate of consumption of energy and generated sludge and maintenance requirements, operation, besides the monitoring suggestion, and mitigating measures of environmental impacts were evaluated in a preliminary project.
8

Remoção de substâncias húmicas na dupla filtração com filtro ascendente de pedregulho / Removal of humic substances in double filtration system using an upflow gravel filter

Benini, Bianca Dieile da Silva 25 April 2003 (has links)
Este trabalho foi realizado com o objetivo de avaliar o comportamento de um sistema de dupla filtração, utilizando filtro ascendente de pedregulho seguido de filtro rápido descendente na remoção de substâncias húmicas. A parte experimental foi realizada em uma instalação piloto, que utilizou como afluente a água do Ribeirão Feijão na qual foi adicionado extrato de substâncias húmicas, previamente extraído de solo turfoso por meio de extração alcalina, para que a cor verdadeira da água de estudo resultasse entre 90 e 110 uH. As condições de coagulação, como gradiente de velocidade, dosagem e pH, foram definidos em ensaios com jarteste. As taxas utilizadas no filtro ascendente em pedregulho foram de 80 e 120 m3/m2.dia e no sistema de filtração rápida descendente de 80, 120, 150, 180, 220 e 240 m3/m2.dia. As carreiras tiveram duração máxima de 72 horas. A utilização do critério de realização de Descargas de Fundos Intermediárias (DFIs), quando o efluente do Filtro Ascendente de Pedregulho (FAP) atingisse valor maior ou igual 50 uH, não permitiu aumento da cor no efluente final. O sistema de dupla filtração estudado foi eficiente na remoção de cor, atingindo diversas vezes remoção completa; outros parâmetros relativos à concentração de substâncias húmicas, como absorvância (254 nm) e Carbono Orgânico Dissolvido (COD), foram removidos entre 89,1 a 93,6% e 27,5 a 48,5% respectivamente. / The present work was carried out to evaluate the removal of humic substances in a double filtration system, comprising on upflow gravel prefilter followed by a rapid down flow filter. Raw water was abstracted from the influent took to the municipal water treatment Plant 2. Humic substances were extracted from peat through alkaline process. The concentrated solution was pumped to raw water in order to obtain true colour of 90-110 Hu in the influent to the pilot plant. Filtration rates studied were as follows: 80 and 120 m3/m2.day in the upflow filter 80, 120, 150, 180, 220 e 240 m3/m2.day in the down flow filter. Maximum filter run length was fixed in 72 hours. Intermediate down flushes in the upflow filter were performed during the run when the effluent colour reached 50 Hu. It is concluded that the system performed efficiently to remove colour; in most part of the effluent colour remained bellow 1 Hu. Absorbance (254 nm) removal resulted high (between 89,1% and 93,6%). Dissolved organic carbon resulted satisfactory (27,5% to 48,5%).
9

Remoção de substâncias húmicas na dupla filtração com filtro ascendente de pedregulho / Removal of humic substances in double filtration system using an upflow gravel filter

Bianca Dieile da Silva Benini 25 April 2003 (has links)
Este trabalho foi realizado com o objetivo de avaliar o comportamento de um sistema de dupla filtração, utilizando filtro ascendente de pedregulho seguido de filtro rápido descendente na remoção de substâncias húmicas. A parte experimental foi realizada em uma instalação piloto, que utilizou como afluente a água do Ribeirão Feijão na qual foi adicionado extrato de substâncias húmicas, previamente extraído de solo turfoso por meio de extração alcalina, para que a cor verdadeira da água de estudo resultasse entre 90 e 110 uH. As condições de coagulação, como gradiente de velocidade, dosagem e pH, foram definidos em ensaios com jarteste. As taxas utilizadas no filtro ascendente em pedregulho foram de 80 e 120 m3/m2.dia e no sistema de filtração rápida descendente de 80, 120, 150, 180, 220 e 240 m3/m2.dia. As carreiras tiveram duração máxima de 72 horas. A utilização do critério de realização de Descargas de Fundos Intermediárias (DFIs), quando o efluente do Filtro Ascendente de Pedregulho (FAP) atingisse valor maior ou igual 50 uH, não permitiu aumento da cor no efluente final. O sistema de dupla filtração estudado foi eficiente na remoção de cor, atingindo diversas vezes remoção completa; outros parâmetros relativos à concentração de substâncias húmicas, como absorvância (254 nm) e Carbono Orgânico Dissolvido (COD), foram removidos entre 89,1 a 93,6% e 27,5 a 48,5% respectivamente. / The present work was carried out to evaluate the removal of humic substances in a double filtration system, comprising on upflow gravel prefilter followed by a rapid down flow filter. Raw water was abstracted from the influent took to the municipal water treatment Plant 2. Humic substances were extracted from peat through alkaline process. The concentrated solution was pumped to raw water in order to obtain true colour of 90-110 Hu in the influent to the pilot plant. Filtration rates studied were as follows: 80 and 120 m3/m2.day in the upflow filter 80, 120, 150, 180, 220 e 240 m3/m2.day in the down flow filter. Maximum filter run length was fixed in 72 hours. Intermediate down flushes in the upflow filter were performed during the run when the effluent colour reached 50 Hu. It is concluded that the system performed efficiently to remove colour; in most part of the effluent colour remained bellow 1 Hu. Absorbance (254 nm) removal resulted high (between 89,1% and 93,6%). Dissolved organic carbon resulted satisfactory (27,5% to 48,5%).

Page generated in 0.1425 seconds