• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 500
  • 2
  • 2
  • 1
  • Tagged with
  • 510
  • 510
  • 159
  • 94
  • 86
  • 74
  • 64
  • 49
  • 45
  • 42
  • 42
  • 42
  • 41
  • 41
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Removal and selective recovery of heavy metals from electroplating effluents

Machado, Maria Manuela Dias January 2010 (has links)
Tese de doutoramento. Engenharia do Ambiente. Faculdade de Engenharia. Universidade do Porto, Instituto Superior de Engenharia do Porto. 2010
162

Degradation of dye-containing textile effluents by enzymatic catalysis

Cristóvão, Raquel Oliveira January 2010 (has links)
Tese de doutoramento. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2010
163

Estudo da aplicação de processos de separação com membranas no tratamento de efluentes de curtume : nanofiltração e eletrodiálise

Streit, Katia Fernanda January 2011 (has links)
O processo industrial de beneficiamento de peles e couros consome grande volume de água e gera efluentes com alto poder de contaminação e degradação do meio ambiente. O tratamento convencional destes efluentes nem sempre é eficiente para atingir o padrão de lançamento estabelecido pela legislação ou para obter água em condições de reuso no processo produtivo. Neste sentido, a busca por novas tecnologias de tratamento de efluentes de curtume é, sem dúvida, uma necessidade e um grande desafio para o setor. Neste trabalho, foi estudada a aplicação de processos de separação com membranas como a nanofiltração (NF) e a eletrodiálise (ED) no tratamento de efluentes de curtume. A nanofiltração apresentou versatilidade para separar a fração orgânica (proteínas, taninos e outros) e parte da fração inorgânica (sais) permitindo a aplicação da eletrodiálise para uma maior remoção dos sais remanescentes no efluente. O permeado produzido apresentou características compatíveis com o reuso de água nas etapas de ribeira do processo produtivo de curtumes. A eletrodiálise foi utilizada para promover uma remoção ainda maior da quantidade de sais presentes no permeado da nanofiltração, com diferentes teores de matéria orgânica. A remoção de íons obtida através da aplicação da técnica de eletrodiálise apresentou comportamento linear e alcançou valores compatíveis com o reuso de água nas etapas mais críticas da produção de couros, como o tingimento e o engraxe. As membranas utilizadas foram avaliadas e submetidas a etapas de limpeza alcalina, que permitiu recuperar as características iniciais das membranas de nanofiltração e restabelecer parte da corrente limite das membranas de eletrodiálise, garantindo, assim, a continuidade dos processos. Com este estudo, constatou-se que as técnicas de nanofiltração e eletrodiálise podem contribuir para que sejam atingidos os padrões de lançamento de efluentes estabelecidos pela legislação e para possibilitar o reuso da água no processo produtivo do curtume minimizando, assim, o impacto ambiental relacionado ao consumo de água e geração de efluentes associado à indústria do couro. / The industrial processing of hides and skins consumes large volumes of water and generates waste with high pollution and environmental degradation. Conventional treatment of these effluents is not always effective to comply with the environmental regulations or to obtain water with characteristics to be reused in the production process. In this sense, the search for new technologies to treat tanning effluents is undoubtedly a need and a great challenge for the industry. In this work, the application of membrane separation processes, such as nanofiltration (NF) and electrodialysis (ED), was studied in the treatment of tanning effluents. Nanofiltration showed versatility to separate the organic fraction (proteins, tannins, etc.) and part of the inorganic fraction (salts), allowing the application of electrodialysis for further removal of remaining salts in the effluent. The permeate produced has presented compatible characteristics with the water reuse in the beamhouse stages in the tanning production process. The electrodialysis was used to promote a greater reduction in the amount of salt present in the nanofiltration permeate with different levels of organic matter. The removal of ions by electrodialysis showed a linear behavior and reached values which are compatible with the water reuse in the most critical stages of leather production, such as dyeing and greasing. The membranes used were evaluated and subjected to alkaline cleaning steps, which allowed the recovery of the initial characteristics of nanofiltration membranes and the reestablishment of part of the current limit of electrodialysis membranes, thus guaranteeing the continuity of the processes. With this study, it was found that the nanofiltration and electrodialysis techniques can contribute to comply with legal environmental standards and to allow water reuse in the tanning production process, helping to minimize the environmental impact associated to water consumption and generation of effluents related to the leather industry.
164

Flotação por Ar Dissolvido (FAD) de micropartículas, caracterização de microbolhas e medidas de força de interação bolha-partícula

Englert, Alexandre Hahn January 2008 (has links)
O presente trabalho descreve um estudo teórico-experimental da flotação por ar dissolvido (FAD) de micropartículas (diâmetro dp < 100 μm), incluindo caracterização de microbolhas (db < 100 μm) pela técnica LTM-BSizer de determinação da distribuição de tamanho de bolhas (DTB) e medidas diretas da força de interação bolha-partícula via microscopia de força atômica (AFM). Visando aperfeiçoar a técnica LTM-BSizer, foi desenvolvido um novo procedimento (NP) automático de processamento/análise de imagens de bolhas. O NP consistiu em um algoritmo contendo as etapas de conversão das imagens coloridas para tons de cinza, limiarização, preenchimento dos “buracos” das bolhas e análise. Imagens de microbolhas geradas por uma bomba centrífuga multiestágio foram utilizadas para comparar os resultados obtidos pelo NP com os obtidos pelo antigo procedimento (AP) da técnica. Diferenças menores que 20 % foram observadas nos resultados obtidos pelos dois procedimentos para o diâmetro médio aritmético, desvio-padrão e diâmetro médio de Sauter das bolhas. O processamento/análise com o NP foi realizado em um tempo inferior (> 30 %) ao requerido pelo AP, mostrando ainda a vantagem de detectar confiavelmente bolhas circulares não-agrupadas nas imagens. Estudos experimentais de FAD de micropartículas de quartzo (diâmetro médio volumétrico de 13,2 ± 0,3 μm) foram realizados utilizando dois sistemas distintos de flotação. As amostras de quartzo foram tratadas com uma amina comercial (agente coletor) e as bolhas foram caracterizadas pela técnica LTM-BSizer. A DTB obtida para as bolhas geradas em uma pressão de saturação de 294 kPa mostrou que 94 % (em número) das mesmas possui db menor que 100 μm, apresentando diâmetros médios de Sauter e aritmético de 79 ± 5 m e 56 ± 3 μm, respectivamente. Valores de recuperação mássica total de quartzo entre 6,4 ± 5,8 % e 53,3 ± 5,9 % foram obtidos na FAD em distintas concentrações de coletor (até 2 mg g-1), sendo a concentração ótima do mesmo determinada em 1 mg g-1. A recuperação de quartzo por flotação real em função de dp mostrou um mínimo local situado em aproximadamente 3-5 μm, contribuindo para a discussão na literatura sobre a existência do mesmo, interpretado como uma mudança no mecanismo de captura bolha-partícula (convecção-difusão). Estudos de FAD com partículas esféricas de sílica (dp = 1 μm) foram ainda realizados utilizando uma célula de flotação contendo uma válvula de três vias, necessária para obtenção de uma coluna d’água acima da suspensão das partículas, minimizando o arraste das mesmas. As partículas foram amplamente caracterizadas (distribuição de tamanho, potencial zeta, rugosidade superficial, umidade e superfície específica), sendo uma fração hidrofobizada com trimetilclorosilano (TMCS) em ciclohexano. As técnicas de flotação em filme e ascensão capilar demonstraram uma maior hidrofobicidade das partículas metiladas com relação às partículas de sílica não-tratadas com TMCS (amostra original). Os resultados de FAD mostraram não haver diferença significativa entre as recuperações mássicas obtidas para as partículas de sílica original e metilada, sendo observado um aumento linear na recuperação (0,1 ± 0,5 % a 27,0 ± 1,2 %) com um aumento do volume de água saturada utilizado (10 a 40 cm3, respectivamente). Ainda, resultados obtidos utilizando um volume de água saturada de 10 cm3 mostraram que a pressão de saturação possui efeito significativo na FAD das partículas esféricas de 1 m (dp). Valores de recuperação medidos experimentalmente mostraram-se relativamente próximos aos correspondentes valores previstos por um modelo teórico da captura bolha-partícula (flotação real). Com a finalidade de investigar diretamente a interação bolha-partícula na flotação, medidas de força-versus-distância entre uma bolha de ar e uma partícula esférica (hidrofílica ou hidrofóbica) em água foram realizadas pela técnica da sonda coloidal. Um microscópio de força atômica comercial foi empregado utilizando-se uma célula de fluido padrão sem anel O-Ring, permitindo contato da água com o ar. Esferas de sílica (dp entre 5 μm e 27 μm), fixas na extremidade de cantilevers em forma de V, foram utilizadas como sondas coloidais hidrofílicas (limpeza a plasma) e hidrofóbicas (exposição a TMCS). Os resultados mostraram claramente que, sob condições extremas de limpeza, somente uma força monotonicamente repulsiva entre a bolha e a partícula hidrofílica (durante a aproximação e afastamento) foi observada. Os dados obtidos com uma sonda hidrofílica de sílica de 5,6 ± 0,2 μm (dp) mostraram-se em boa conformidade com modelos teóricos (aproximação da superposição não-linear e Hogg-Healy-Fuerstenau) para a interação bolha-partícula hidrofílica, colaborando para elucidar dados experimentais controversos na literatura referentes à correspondente força de interação. As curvas de força obtidas entre uma bolha e uma partícula hidrofóbica apresentaram tipicamente um pulo-para-contato durante a aproximação bolha/partícula e uma força de rompimento no afastamento das mesmas, confirmando a existência de uma força atrativa na interação. Valores de 107 ± 18 nm e -1,5 ± 0,2 μN foram obtidos (com uma sonda de 27 ± 1 μm) para a distância de pulo-para-contato e força de rompimento, respectivamente. A alta reprodutibilidade da técnica da sonda coloidal na medida das curvas de força bolha-partícula (hidrofílica e hidrofóbica) foi demonstrada. / The present work describes a theoretical/experimental study on the dissolved air flotation (DAF) of microparticles (diameter dp < 100 μm), including characterisation of microbubbles (db < 100 μm) by the LTM-BSizer technique of bubble size distribution (BSD) determination and direct measurements of bubble-particle interaction force via atomic force microscopy (AFM). In order to improve the LTM-BSizer technique, an automatic new procedure (NP) of processing/analysis of bubble images was developed. The NP consisted of an algorithm having the steps of image conversion from color to grayscale, thresholding, filling of bubble “holes” and analysis. Images of microbubbles produced by a multistage centrifugal pump were utilised to compare the results obtained via the NP with the corresponding data obtained by the original procedure (OP) of the technique. Differences smaller than 20 % were observed in the values obtained by both procedures for the arithmetic mean diameter, standard deviation and Sauter mean diameter of the bubbles. Processing/analysis with the NP was conducted in a lower time (> 30 %) than the one required by the OP, showing also the advantage of reliably detecting bubbles as single circles (not as clusters) on the images. Experimental studies for the DAF of quartz microparticles (volume-moment diameter of 13.2 ± 0.3 μm), using two different flotation setups, were conducted. Quartz samples were treated with a commercial amine (collector agent) and bubbles were characterised by the LTM-BSizer technique. BSD obtained for the bubbles generated at a saturation pressure of 294 kPa showed 94 % (by number) of the bubbles having db lower than 100 μm, with a Sauter and arithmetic mean diameters of 79 ± 5 μm and 56 ± 3 μm, respectively. Values of total quartz recovery ranging from 6.4 ± 5.8 % to 53.3 ± 5.9 % (by mass) were obtained for the DAF experiments under different collector concentrations (up to 2 mg g-1), with an optimal concentration found at 1 mg g-1. Quartz recovery by true flotation as a function of dp exhibited a local minimum at approximately 3-5 μm, contributing to the discussion in the literature about the existence of such minimum, interpreted as a change in particle-bubble collection mechanism (convection-diffusion). DAF studies using spherical silica particles (dp = 1 μm) were conducted with a flotation cell containing a three-way tap, aiming the formation of a water column above the particle suspension and thus minimizing particle entrainment. Particles were fully characterised (size distribution, zeta potential, surface roughness, water content and specific surface area), being a fraction hidrophobized by trimethylchlorosilane (TMCS) in cyclohexane. The film flotation and capillary rise techniques demonstrated that the methylated particles were more hydrophobic than the untreated silica particles (original sample). DAF experiments showed no significant difference between mass recovery values obtained for the original and methylated silica particles, being observed a linear increase in recovery (0.1 ± 0.5 % to 27.0 ± 1.2 %) with an increase in saturated water volume (10 to 40 cm3,respectively). Furthermore, results obtained using a saturated water volume of 10 cm3 have shown that the saturation pressure had a significant effect on the DAF of 1 μm (dp) spherical particles. Experimental recovery values were in fairly good agreement with corresponding values predicted by a theoretical model of particle-bubble capture (true flotation). Aiming to directly investigate the bubble-particle interaction in flotation, force-distance measurements between an air bubble and a spherical particle (hydrophilic or hydrophobic) in water were conducted using the colloid probe technique. A commercial atomic force microscope was employed using a standard fluid cell without O-Ring, allowing contact of water with the air. Silica spheres (dp between 5 m and 27 μm) attached to the end of V-shaped cantilevers were utilised as hydrophilic (plasma cleaning) and hydrophobic (TMCS exposure) colloid probes. Results showed clearly that, under very clean conditions, only a monotonic repulsive force (upon approach and retraction) between the bubble and the hydrophilic particle was observed. Experimental data obtained using a 5.6 ± 0.2 μm (dp) hydrophilic silica probe are in good agreement with theoretical models (non-linear superposition approximation and Hogg-Healy-Fuerstenau) for the hydrophilic particle-bubble interaction, contributing to elucidate controversial experimental data reported in the literature on such interaction force. Force-curves obtained between a bubble and a hydrophobic particle typically showed a jump-into-contact upon bubble-particle approach and a detachment force on separation, corroborating the existence of an attractive force in the interaction. Values of 107 ± 18 nm and -1.5 ± 0.2 μN were obtained (using a 27 ± 1 μm probe) for the jump-into-contact distance and detachment force, respectively. The high reproducibility of the colloid probe technique for measuring bubble-particle (hydrophilic and hydrophobic) force curves was demonstrated.
165

Tratamento anaeróbio de efluente de curtume de acabamento associado a membranas de micro e ultrafiltração

Beal, Lademir Luiz January 2004 (has links)
Esta pesquisa teve por objetivo avaliar aspectos fundamentais para o emprego de processo anaeróbio associado a membranas de micro e ultrafiltração no tratamento de efluentes de curtume oriundos do processo de acabamento. Para tanto, foi utilizada uma unidade piloto composta de um reator anaeróbio de mistura completa com um volume útil de 40 L, uma unidade de microfiltração para separação de biomassa e uma unidade de ultrafiltração para reter no sistema compostos macromoleculares (taninos). O material constituinte das membranas era cerâmica e o diâmetro médio de poro, especificado pelo fabricante, da microfiltração foi 0,2 mm e da ultrafiltração 0,005 mm. A biomassa no reator anaeróbio foi inoculada para que a concentração inicial fosse de 7.000 mg/L de SVT, sendo a origem desta um reator UASB tratando efluente de uma fábrica de gelatina. O trabalho foi desenvolvido em três etapas, sendo utilizadas diferentes pressões nas membranas, a saber: na primeira etapa as membranas foram operadas com um pressão de 800 kPa, na segunda com uma pressão de 600 kPa e na terceira etapa a pressão utilizada foi de 400 kPa. A remoção de cromo foi superior a 95% em todas as etapas, sendo que a maior remoção ocorreu no conjunto reator anaeróbio e microfiltração. Este comportamento deveu-se à fixação deste metal na biomassa e à conseqüente retenção desta na operação de microfiltração. A remoção média de matéria orgânica, avaliada através do parâmetro DQO, para as três etapas estudadas foi 68,13%, 58,32% e 60,17% e, em todo o sistema, de 81,93%, 76,20% e 69,15%. Ocorreu remoção total dos sólidos suspensos já que o diâmetro de poro da membrana de microfiltração era 55,55% inferior ao diâmetro de poro utilizado nas membranas para determinação de sólidos suspensos. Já para sólidos totais, onde inclui-se os dissolvidos, esta eficiência variou de 42% a 63%.
166

Produção e aplicação de membranas com polímeros convencionais e polianilina para uso em eletrodiálise no tratamento de efluentes industriais

Amado, Franco Dani Rico January 2006 (has links)
Neste estudo foram produzidas diferentes membranas utilizando polímeros convencionais (poliestireno de alto impacto, HIPS e poliuretano, PU) com polianilinas (PAnis), com o objetivo de tratar por eletrodiálise efluentes de galvanoplastia e de curtimento de peles. Foram testados dois métodos de obtenção de membranas com HIPS e PAni (dissolução com posterior evaporação do solvente e a mistura mecânica com posterior moldagem sob pressão). A obtenção de membranas de PU e PAni foi realizada através da preparação de uma rede de polímeros interpenetrantes (IPNs). As membranas foram caracterizadas através de espectroscopia FTIR, microscopia eletrônica de varredura, análise termogravimétrica e análise dinâmico mecânica. O transporte iônico através das membranas HIPS e PAni foi avaliado usando uma célula de bancada com três compartimentos. As membranas apresentaram resultados de permeabilidade a cromo e sódio similares à membrana comercial Nafion 450. Os ensaios de eletrodiálise também foram executados usando um sistema piloto comercial para avaliar o desempenho das membranas com dimensões superiores (172 cm2) as amostras utilizadas em célula de bancada (16 cm2). Foi estimado o custo de preparação da membrana e da polianilina utilizada. / Different membranes were produced in this study, using conventional polymer (high impact polystyrene and polyurethane) and polyaniline, aiming to treat metal finishing industry and tannery wastewater by electrodialysis. Two methods of membranes production with HIPS and PAni were tested (dissolution with subsequent solvent evaporation and mechanical mixture with subsequent pressing with heating), with the objective of better understanding the involved phenomena in different obtained methods. The obtaining of PU and PAni membranes was accomplished through the preparation of the interpenetrating polymer networks (IPNs). The membranes characterization was done by FTIR spectroscopic, scanning electron microscopy (SEM), thermogravimetric (TGA) and dynamic mechanical (DMA) analysis. The study of the ionic transport through the membranes was evaluated using a three-compartment cell. The results obtained using these membranes, were compared to those obtained with the commercial membrane Nafion 450, being found a chromium and sodium transport similar to the commercial membrane. The electrodialysis experimental assays were also carried out in a commercial pilot system to evaluate the performance of the membranes with superior dimensions (172 cm2) of the samples used in laboratory cell (16 cm2). The preliminary cost of preparation of the membrane and polyaniline used was also evaluated.
167

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
168

Banhados construídos como sistema terciário para reúso da água industrial em uma empresa metal-mecânica

Curia, Ana Cristina January 2010 (has links)
Com a poluição dos recursos hídricos e o substancial aumento do custo com água, o reúso da água tornou-se uma alternativa a ser considerada nas operações industriais. Essa iniciativa pode auxiliar na busca de uma solução para problemas de escassez de recursos hídricos e na diminuição de custos operacionais das empresas. O problema a ser abordado neste estudo está relacionado com as dificuldades técnicas do tratamento de efluentes para atingir a qualidade necessária ao reúso da água e a necessidade de atender os padrões de lançamento de efluentes estabelecidos pela legislação ambiental tendo em vista a impossibilidade de reúso total do efluente tratado. O principal objetivo deste trabalho foi estudar a remoção de poluentes gerados em uma indústria metal-mecânica por meio de plantas aquáticas em escala piloto e industrial e avaliar o potencial de reúso do efluente como água industrial em diferentes aplicações (descarga de vaso sanitário, irrigação paisagística, torre de resfriamento, lavagem de equipamentos, usinagem de peças e água de incêndio). Para este estudo foram projetadas e construídas uma planta piloto e outra planta em escala industrial em uma empresa situada na região metropolitana de Porto Alegre. O sistema foi constituído por um banhado construído como sistema terciário para simular as condições de tratamento do efluente industrial. As macrófitas foram acondicionadas em tanques de polietileno com capacidade total de 1 m3 considerando o tratamento de efluente de 2 m3/dia. O efluente circulou com um fluxo sub-superficial horizontal através da matriz porosa de areia grossa e brita, na quais estavam presentes as raízes das macrófitas das espécies Junco (Scirpus sp.) e Taboa (Typha sp.). A planta em escala industrial foi executada seguindo os mesmos padrões da planta piloto, porém, com algumas modificações. A planta industrial é constituída de 4 lagoas de fluxo sub-superficial horizontal com dimensões idênticas de 11,50 m de largura, 7,0 m de comprimento e 0,8 m de profundidade útil; camada suporte composta de brita zero; construção das lagoas com argila compactada; uso das espécies Junco (Scirpus sp.) e Taboa (Typha sp.) nas quatros lagoas de forma intercalada; estação de bombeamento e rede para o reúso do efluente tratado. O estudo de tratabilidade da planta em escala piloto e industrial foi realizado por monitoramento dos parâmetros físico-químicos e biológicos. Mesmo com algumas variações de carga e problemas operacionais, o sistema apresentou um comportamento adequado para a remoção de poluentes na planta piloto/ industrial, cujos resultados médios de eficiência de remoção foram de 73%/49%, 61%/42%, 56%/46%, 54%/49%, 57%/46% e 66%/69% de fósforo total, NTK, NH4-N, DQO, DBO, SS, respectivamente. As análises da camada suporte em conjunto com o sistema radicular e parte aérea apontam um possível potencial de emprego destes resíduos no solo como adubo devido a sua composição. O sistema de tratamento com banhado construído para reúso da água mostrou ser efetivo para redução de custos cujo período de payback médio é de 4,5 anos. Durante o experimento foi possível verificar que o reúso de água consiste em uma estratégia de sustentabilidade para redução do consumo de água potável (economia de 18 % em média e 44% máxima do consumo total). / With the pollution of water resources and the substantial increase in the cost of water, water reuse has become an alternative to be considered in industrial operations. This initiative can support in finding a solution to problems of scarcity water resources and minimizing operating costs in the companies. The problem to be considering in this study is related to the technical difficulties of treating effluent to aiming the quality necessary for water reuse and the need to reach effluent discharge standards set by environmental legislation considering the impossibility of total effluent treated reuse. The objective of this work was to study the pollutants removal generated in a metalworking industry effluent by aquatic plants in pilot and industrial scales and evaluate the potential for effluent reuse as industrial water in different applications (flushing, landscape irrigation, cooling tower, vehicles washing, machining of parts and firefighting). A pilot plant was built in an industry consisting of a constructed wetland as a tertiary system to simulate the conditions of treatment of an industrial effluent. The macrophytes were conditioned in polyethylene tanks with a total capacity of 1 m3 foreseeing the treatment of 2 m3/day. The effluent circulated in a horizontal subsurface flow through a porous matrix of thick sand and gravel in which the roots of macrophytes of the species Reed (Scirpus sp.) and Cattail (Typha sp.) were developed. The industrial scale plant was executed following the same standards by the pilot plant with some modifications. The industrial plant was composed by four horizontal sub-surface flow lagoons with equal dimensions of 11m width, 7m length and 0.8m useful depth; a support layer composed by gravel; lagoons with compacted clay; Reed (Scirpus sp.) and Cattail (Typha sp.) aquatic plant were interchangeably introduced in the four lagoons; pump station and network of pipes for the reuse of the treated effluent. The study of the treatment was carried out by monitoring of the physical-chemical and biological parameters. Even though some operational load variations and operational problems, the system showed an adequate behavior for the removal of pollutants, in pilot and industrial scales whose the average removal efficiency results were 73%/49%, 61%/42%, 56%/46%, 54%/49%, 57%/46% e 66%/69%, respectively. The analyses of the support layer with the root system and aerial part of the plant pointed out a possible potential of use of these wastes in the ground as fertilizer due to its composition. The constructed wetland treatment system for reuse of water showed to be effective for reduction of costs and the payback is very attractive (4.5 years). During the experiment it was possible to verify that reuse of water is a useful sustainability strategy to reduction of utilization of drinking water in industrial operations (saving of 18 % in average and 44% maximum of total consumption).
169

Avaliação do processo de eletrodiálise reversa no tratamento de efluentes de refinaria de petróleo

Machado, Mara de Barros January 2008 (has links)
Este trabalho teve como objetivo avaliar a aplicação da eletrodiálise reversa no tratamento de efluente final de refinaria para reuso em sistema de resfriamento. O estudo foi conduzido nas instalações da Refinaria Gabriel Passos (REGAP)- MG, com efluente real, proveniente da saída da Estação de Tratamento de Despejos Industriais (E.T.D.I.), e utilizando para os testes uma unidade-piloto de eletrodiálise reversa com capacidade de tratamento de 2 m3/h. A utilização do processo de dessalinização por EDR teve o objetivo de reduzir sólidos totais dissolvidos no efluente de aproximadamente 1.240 mg/L para 310 mg/L, o que equivale a cloretos de 460 mg/L e 100 mg/L respectivamente, para atingir a qualidade requerida para água de make-up da torre de resfriamento da REGAP. Inicialmente foi feita uma avaliação comparativa com o processo de osmose inversa, no qual foi constatada, com o uso da EDR, a maior continuidade operacional, menores problemas de incrustação e menor exigência para o pré-tratamento do efluente. No estudo com a EDR foram realizados testes variando-se a vazão, de 600 a 2000 L/h de produto; voltagem de 200 a 370V e número de estágios. Durante os testes foi realizado o monitoramento operacional e analítico da água de alimentação da EDR, do produto (solução diluída) e do rejeito (concentrado salino), sendo os dados avaliados e correlacionados para determinação da densidade de corrente, taxa hidráulica, eficiência e taxa de remoção de sais. A análise da formação de incrustações e deposições na superfície das membranas levou ao estabelecimento de um procedimento de limpeza química. O estudo foi conduzido de forma a obter a otimização da operação com rendimento necessário na remoção de sólidos dissolvidos, menor custo energético e de manutenção. Após os testes foi selecionada a condição otimizada da unidade piloto: módulo em 2 estágios, vazão de 1,1 m3/h e voltagem de 275V. Para este condição o consumo energético foi de 1,95 KWh/m3 de efluente tratado. Os resultados mostraram a viabilidade técnica-econômica do uso da EDR para remoção de sais de efluente final de refinaria para aplicação em reposição de sistemas de resfriamento. / This study aimed the evaluation of the application of electrodialysis reversal in final effluent treatment targeting the reuse in cooling towers. The study was done in Gabriel Passos Refinery (REGAP) - MG, with real effluent, from the Industrial Effluent Treatment Station (ETDI), and was held in a pilot plant of electrodialysis reversal with a treatment capacity of 2 m3 / h. The use of the desalination process with EDR target the reduction of total dissolved solids in the effluent of about 1.240 mg / L to 310 mg / L, equivalent to chlorides of 460 mg / L and 100 mg / L respectively, to reach the required quality of make-up water in the REGAP cooling tower. It was originally done a comparative evaluation with reverse osmosis process, another method of membrane desalination. Electrodialysis was selected because of its operating stability, less problems with scaling and fouling, dispensing the use of conditioning chemicals, and the requirement of a simpler pre- treatment The tests with EDR were carried out ranging the product flux for 600 to 2.000 L/h, the voltage for 200 to 370V and the number of hydraulic stages. During the tests were analyzed operational and analytical data in the EDR feed, product (diluted solution) and reject (concentrated solution), being the parameters analyzed and correlated to determine the current density, hydraulic rate, efficiency and salts removal rate. The analysis of fouling and deposition formation on the membranes surface led to an establishment of a chemical cleaning procedure. This study was conducted in order to obtain the operational optimizing with the necessary income to remove dissolved solids, with lower energy cost and maintenance. After the tests was selected the optimum condition for the pilot plant: stack in 2 stages, flow rate of 1.1 m3/h and voltage of 275V. In this condition the power consumption was 1.95 KWh/m3 of treated effluent. The results showed the technical and economic feasibility for the EDR in removing salts from refinery effluents for reuse in make up of cooling systems.
170

Estudo da aplicação de processos de separação com membranas no tratamento de efluentes de curtume : nanofiltração e eletrodiálise

Streit, Katia Fernanda January 2011 (has links)
O processo industrial de beneficiamento de peles e couros consome grande volume de água e gera efluentes com alto poder de contaminação e degradação do meio ambiente. O tratamento convencional destes efluentes nem sempre é eficiente para atingir o padrão de lançamento estabelecido pela legislação ou para obter água em condições de reuso no processo produtivo. Neste sentido, a busca por novas tecnologias de tratamento de efluentes de curtume é, sem dúvida, uma necessidade e um grande desafio para o setor. Neste trabalho, foi estudada a aplicação de processos de separação com membranas como a nanofiltração (NF) e a eletrodiálise (ED) no tratamento de efluentes de curtume. A nanofiltração apresentou versatilidade para separar a fração orgânica (proteínas, taninos e outros) e parte da fração inorgânica (sais) permitindo a aplicação da eletrodiálise para uma maior remoção dos sais remanescentes no efluente. O permeado produzido apresentou características compatíveis com o reuso de água nas etapas de ribeira do processo produtivo de curtumes. A eletrodiálise foi utilizada para promover uma remoção ainda maior da quantidade de sais presentes no permeado da nanofiltração, com diferentes teores de matéria orgânica. A remoção de íons obtida através da aplicação da técnica de eletrodiálise apresentou comportamento linear e alcançou valores compatíveis com o reuso de água nas etapas mais críticas da produção de couros, como o tingimento e o engraxe. As membranas utilizadas foram avaliadas e submetidas a etapas de limpeza alcalina, que permitiu recuperar as características iniciais das membranas de nanofiltração e restabelecer parte da corrente limite das membranas de eletrodiálise, garantindo, assim, a continuidade dos processos. Com este estudo, constatou-se que as técnicas de nanofiltração e eletrodiálise podem contribuir para que sejam atingidos os padrões de lançamento de efluentes estabelecidos pela legislação e para possibilitar o reuso da água no processo produtivo do curtume minimizando, assim, o impacto ambiental relacionado ao consumo de água e geração de efluentes associado à indústria do couro. / The industrial processing of hides and skins consumes large volumes of water and generates waste with high pollution and environmental degradation. Conventional treatment of these effluents is not always effective to comply with the environmental regulations or to obtain water with characteristics to be reused in the production process. In this sense, the search for new technologies to treat tanning effluents is undoubtedly a need and a great challenge for the industry. In this work, the application of membrane separation processes, such as nanofiltration (NF) and electrodialysis (ED), was studied in the treatment of tanning effluents. Nanofiltration showed versatility to separate the organic fraction (proteins, tannins, etc.) and part of the inorganic fraction (salts), allowing the application of electrodialysis for further removal of remaining salts in the effluent. The permeate produced has presented compatible characteristics with the water reuse in the beamhouse stages in the tanning production process. The electrodialysis was used to promote a greater reduction in the amount of salt present in the nanofiltration permeate with different levels of organic matter. The removal of ions by electrodialysis showed a linear behavior and reached values which are compatible with the water reuse in the most critical stages of leather production, such as dyeing and greasing. The membranes used were evaluated and subjected to alkaline cleaning steps, which allowed the recovery of the initial characteristics of nanofiltration membranes and the reestablishment of part of the current limit of electrodialysis membranes, thus guaranteeing the continuity of the processes. With this study, it was found that the nanofiltration and electrodialysis techniques can contribute to comply with legal environmental standards and to allow water reuse in the tanning production process, helping to minimize the environmental impact associated to water consumption and generation of effluents related to the leather industry.

Page generated in 0.1427 seconds