• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Aplicações da espectrometria de massas em caracterização e quantificação de matrizes biológicas / Mass spectrometry applications for characterization and quantitation in biological matrices

Porcari, Andréia de Melo, 1983- 03 December 2012 (has links)
Orientador: Marcos Nogueira Eberlin / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-20T20:29:02Z (GMT). No. of bitstreams: 1 Porcari_AndreiadeMelo_M.pdf: 3504713 bytes, checksum: 67c674763a09cf16900c073f27cd5133 (MD5) Previous issue date: 2012 / Resumo: O presente trabalho utiliza a Espectrometria de Massas para caracterização e quantificação de diferentes analitos em matrizes biológicas. Inicialmente é demonstrado o desenvolvimento de uma técnica para análise direta de triacilgliceróis (TAG) em carnes e tecidos, que podem então ser caracterizados por seu perfil lipídico. Nesta técnica, uma etapa de foto aquecimento visa extrair quase instantaneamente TAG da matriz, utilizando pouco ou nenhum solvente. O conteúdo extraído e coletado num papel pardo é então analisado por EASI-MS (Easy Ambient Sonic-spray Ionization - Mass Spectrometry), revelando o perfil de TAG em poucos segundos, sem necessidade de hidrólise, derivação ou outras extrações. Thermally-imprinted EASI-MS (T-EASI-MS) é uma técnica capaz de diferenciar tipos de carnes e seus resultados mostraram-se concordantes com a literatura e com outras técnicas tradicionais para análise de lipídios. Num segundo momento, utilizou-se a espectrometria de massas como ferramenta de quantificação, através do desenvolvimento de dois métodos analíticos para análise de cortisol em plasma e leite bovinos, utilizando LC-MS/MS (cromatografia líquida acoplada à espectrometria de massas seqüencial). Os métodos aqui desenvolvidos foram validados utilizando a metodologia de compatibilização de matriz (para o plasma) e de calibração direta em solvente (curva não extraída) para o leite. Ambos os métodos empregaram pequeno volume de amostra e forneceram baixos limites de quantificação (0,1 ng mL e 0,15 ng mL de cortisol para o plasma e leite, respectivamente). A metodologia desenvolvida foi aplicada para análise de dois experimentos veterinários. No primeiro foi investigada a correlação entre as concentrações de cortisol no plasma e no leite bovino, bem como o efeito da ordenha sobre a concentração do cortisol nesses fluídos biológicos. No segundo nível de cortisol em vacas com e sem mastite sub-clínica foi investigado e os resultados foram comparados aos resultados obtidos por ELISA (Enzime-linked Immunosorbent Assay) para as mesmas amostras / Abstract: This research uses mass spectrometry (MS) as a tool to characterize and quantify different analytes in biological matrices. At first, the development of a technique for direct analysis of triacylglycerols (TAG) in meats and animal tissues is shown. This technique allows sample characterization through its lipid profile. It starts with a photo-heating process which aims to extract, almost instantaneously, TAG from the matrix, using very little amounts of solvent. The extract is collected on a paper which is then analyzed by EASI-MS (easy ambient sonic-spray ionization), thus revealing the TAG profile in a few seconds, without the use of hydrolysis, derivatization or exhaustive extractions. Thermally-imprinted EASI-MS (T-EASI-MS) is able to differentiate kinds of meats and has been shown to be in agreement with previous reported data and results from traditional techniques used for lipid analysis of the same samples. In a second phase, this research uses MS as a tool for quantitative analyses, through the development of two analytical methods for cortisol analysis in bovine plasma and milk, using a LC-MS/MS (liquid chromatography - tandem mass spectrometry) system. These methods were fully validated using the matrix matched methodology for plasma analysis and a non-extracted calibration curve (prepared in solvent) for milk analysis. Both methodologies use small amounts of sample and achieved very low limits of quantification (0.1 ng mL and 0.15 ng mL of cortisol for plasma and milk, respectively). The methods were applied to the analysis of samples from two veterinary experiments. In the first one, the aim was to investigate the correlation between bovine plasma and milk cortisol concentrations, as well as to determine if the milking process can change basal cortisol level in these fluids. In the second experiment, the aim was to evaluate whether milk cortisol concentrations varied or not in cows with or without sub-clinical mastitis. The samples of the second experiment were also analyzed by ELISA (enzime-linked immunosorbent assay) in order to compare the results with those from LC-MS/MS / Mestrado / Quimica Analitica / Mestre em Química
2

Viscosidade de compostos e misturas graxas : determinação experimental e desenvolvimento de uma metodologia de predição / Viscosity of fatty compounds and mistures : experimental measurement and development of a predictive aproach

Rabelo, Juliana 20 September 2005 (has links)
Orientador: Antonio Jose de Almeida Meirelles / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-05T02:09:23Z (GMT). No. of bitstreams: 1 Rabelo_Juliana_M.pdf: 2293566 bytes, checksum: 7592ac89859a7882bd6ce62626eb622a (MD5) Previous issue date: 2005 / Resumo: Com o objetivo de predizer e descrever a viscosidade de diferentes compostos graxos e suas misturas, este trabalho desenvolveu um procedimento de cálculo baseado em métodos de contribuição de grupos. Um novo modelo para predição da viscosidade de substâncias graxas puras foi desenvolvido, inspirado no modelo proposto por CERIANI e MEIRELLES (2004) para predição da pressão de vapor. O presente trabalho ajustou parâmetros de contribuição de grupos para o modelo proposto, tomando como base dados experimentais de compostos graxos (ácidos graxos, álcoois graxos, ésteres graxos e triacilgliceróis) presentes na literatura. Utilizando o método MARQUARD, o ajuste dos parâmetros envolveu a minimização de uma função objetivo que representava o somatório dos desvios relativos entre os valores experimentais e calculados de viscosidade dinâmica de compostos graxos puros. Tal processo foi realizado através de programas desenvolvidos no SAS ® e de planilhas eletrônicas em EXCEL, nas quais podiam ser feitas análises ponto a ponto dos ajustes. O trabalho envolveu ainda a determinação de um conjunto extenso de dados experimentais de viscosidade de misturas graxas, a caracterização química de óleos vegetais utilizados no teste da capacidade preditiva do modelo e teste dos modelos de estimativa de densidade e de viscosidade de misturas com parâmetros disponíveis na literatura. Confirmada a sua eficiência, este modelo será de interesse para o desenvolvimento de processos e projetos de equipamentos industriais, uma vez que dados de viscosidade de compostos graxos são escassos na literatura / Abstract: This work aims to describe and predict the viscosity of different fatty compounds and their mixtures by developing a predictive model based on the concept of group contribution. A new model developed in this work was based in the method suggested by CERIANI e MEIRELLES (2004) for vapor pressure prediction. All the group parameters have been adjusted based on experimental data for fatty acids, fatty alcohols, fatty esters and triacylglycerols. Using the method of MARQUARD, the adjustment of parameters have minimized an objective function which is based on the sum of the relative deviation between the experimental and calculated values of the dynamic viscosity of fatty compounds. The softwares used for this work was SAS ® and EXCEL. This work has also determined an extensive experimental data bank of viscosities of fatty compounds mixtures. Some models of densities and viscosities found in the literature have been tested. The method suggested in this work can be a valuable tool for the design of industrial equipments of the oil industry, since such experimental data are relatively scarce in the literature / Mestrado / Mestre em Engenharia de Alimentos
3

Caracterização de lecitinas comerciais por espectrometria de massas ambiente com ionização sonic-spray / Characterization of commercial lecithins by easy ambient sonic-spray ionization mass spectrometry

Fernandes, Gabriel Deschamps, 1988- 19 August 2018 (has links)
Orientador: Daniel Barrera Arellano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-19T21:15:47Z (GMT). No. of bitstreams: 1 Fernandes_GabrielDeschamps_M.pdf: 1854677 bytes, checksum: e57833484e8f9ad4a136187bed59d8d2 (MD5) Previous issue date: 2012 / Resumo: Os fosfolipídios são definidos como o grupo de moléculas que contém um grupamento fosfato. Por apresentarem características anfipáticas, este grupo de moléculas se organiza naturalmente em bicamadas, originando as membranas dos seres vivos. Industrialmente são capazes de estabelecer interfaces óleo/água, possibilitando a formação e estabilização de emulsões. Este grupo de moléculas é bastante diverso quimicamente, sendo os principais componentes a fosfatidilcolina, fosfatidiletanolamina, fosfatidilserina, fosfatidilinositol, ácido fosfatídico e esfingomielina. A determinação e quantificação desses compostos é bastante laboriosa tanto nos meios industriais como acadêmicos, envolvendo, entre outras, etapas de digestão ácida e incineração. A espectrometria de massas desponta como uma técnica bastante favorável à análise de lipídios, englobando desde estudos clínicos até de biocombustíveis. Mais recentemente, as técnicas de espectrometria de massas com ionização ambiente facilitaram o acesso a este tipo de tecnologia, diminuindo os custos de implantação e principalmente de operação. A ionização ambiente por sonic-spray (EASI, easy ambient sonic-spray ionization) denota-se como uma técnica adequada à análise de lipídios, uma vez que não aplica alta voltagem e alta temperatura, prevenindo, portanto possíveis degradações destas moléculas. Este trabalho teve como objetivo, estudar a ionização de fosfolipídios (PL) e triacilgliceróis (TAG) frente à técnica EASI-MS, bem como, estudar a viabilidade técnica da caracterização de lecitinas comerciais por meio da técnica EASI-MS. Quanto à ionização dos lipídios, foi possível observar, nas condições de estudo, que dentro de uma mesma classe (PL ou TAG) a intensidade de ionização diminui com o aumento da cadeia dos ácidos graxos e aumenta com o aumento das insaturações. Para o estudo de caracterização foram utilizadas seis amostras de lecitina de soja comercial, obtidas por diferentes processos. As amostras foram diluídas em clorofórmio e submetidas à análise de EASI-MS, nos modos positivo e negativo. Nos espectros de EASI(+)-MS, os íons mais representativos foram os íons correspondentes à fosfatidilcolina e aos triacilgliceróis, enquanto que, nos espectros de EASI(-)-MS os íons mais representativos corresponderam à fosfatidiletanolamina, aos ácidos graxos livres e aos glicofosfolipídios. A técnica EASI-MS mostrou-se eficiente na caracterização das lecitinas comerciais. Sendo uma técnica rápida e que não exige preparo de amostra / Abstract: Phospholipids are defined as the group of molecules containing a phosphate grouping. As they have amphipathic characteristics, this group of molecules naturally organizes bilayer, origin the membranes of living organism and are able to establish an industrial oil / water interface, allowing the formation and stabilization of emulsions. This group of molecules is very chemically different; the main components are phosphatidylcholine, phosphatidylethanolamine, phosphatidylserine, phosphatidylinositol, phosphatidic acid and sphingomyelin. The determination and quantification of these compounds is very laborious for the academic and industrial circles, involving, among others, several steps, like acid digestion and incineration. Mass spectrometry is emerging as a very favorable tool of lipids analysis, since clinical and biofuel studies. Recently, the techniques of ambient mass spectrometry have facilitated the access to this type of technology, reducing deployment costs and especially the operation. Easy ambient sonic-spray ionization (EASI) denotes as a suitable technique to analyze the lipids, since it does not apply high voltage and high temperature, and thereby prevent possible degradation of these molecules. This work aimed to study the ionization of phospholipids (PL) and triacylglycerols (TAG) in EASIMS technique, as well as studying the technical feasibility of the characterization of commercial lecithins by EASI-MS. On the lipid ionization, it was observed, under the conditions of the study, that within the same class (TAG or PL) the ionization intensity decreases with increasing of fatty acids chains and increases with increasing of unsaturation. For characterization studies were used six samples of commercial soy lecithin, obtained by different processes. Samples were diluted in chloroform and analyzed for EASI-MS in positive and negative ion modes. In the spectra of EASI (+)- MS, the most representing ions are corresponding to triglycerides and phosphatidylcholine, whereas in the spectra of EASI (-)-MS the most representative ions correspond to the phosphatidylethanolamine, the free fatty acids and glicophospholipidios. The EASI-MS technique was efficient in the characterization of commercial lecithins. As a fast technique and does not require sample preparation / Mestrado / Tecnologia de Alimentos / Mestre em Tecnologia de Alimentos

Page generated in 0.1562 seconds