11

Optimización del sistema de bombeo de mina San Cristóbal

Gamboa Alarcón, Nykue Antonio January 2014 (has links)
Publicación a texto completo no autorizada por el autor / Manifiesta que la mina San Cristóbal actualmente presenta dos grandes problemas en el sistema de bombeo, por un lado tenemos el fuerte pago mensual que se hace por alquiler de bombas sumergibles de baja eficiencia y por otro lado las pérdidas por inundaciones frecuentes que representan dejar de producir, pagar bombas 16 adicionales para recuperación y fuertes gastos en reparaciones muy frecuentes de bombas estacionarias de línea principal. Determina a un estudio detallado del sistema de bombeo de aguas acidas en mina San Cristóbal desde el nivel 1120 hasta la cuneta del nivel 820 de donde el agua sale por gravedad por túnel victoria hacia la planta de tratamiento. / Trabajo de suficiencia profesional
12

Análisis de falla de tapones inflables Thru Tubing corridos Coiled Tubing durante las operaciones de abandono del pozo Mirasol-1

Monar Flores, Manuel Alejandro January 2014 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Realiza el análisis de falla de dos tapones inflables tipo Thru Tubing corridos con Coiled Tubing durante las operaciones de abandono del pozo Mirasol 1 de la empresa Petrominerales Colombia Limited. Lo innovador del Coiled Tubing es que se dobla plásticamente desde el carrete al arco de guía del cuello de ganso. La deformación cedente para el Coiled Tubing se basa en el módulo de Young’E y el esfuerzo de cedencia syE= 30*106 y el típico para el Coiled Tubing sy=80.000lpc, de aquí que la deformación cedente sea dada por sy/E=0,003 o 3.000 micro deformación. / Trabajo de suficiencia profesional
13

Diseño de la ampliación del sistema de bombeo de pulpa desde la cota 490 m.s.n.m (poza N°5) hasta la cota 522 m.s.n.m (poza n°6) en la refinería de Cajamarquilla

Culqui Perez, Cristian Adolfo January 2014 (has links)
Diseña el nuevo sistema de bombeo desde la descarga actual en la corona del dique de la poza N°5 hasta la corona del dique de la poza N°6 por la cual se plantea hacer una estación de bombeo en la corona de la poza N°5 y su línea de impulsión para poder elevar la pulpa de este nivel hasta la nueva descarga ubicada en la corona de la poza N°6 (522 m.s.n.m). La Refinería de Cajamarquilla (RDC) que actualmente es propiedad de la empresa Votorantim Metais S.A., es una empresa dedicada al procesamiento metalúrgico de concentrados de zinc y a la comercialización de zinc refinado de alta pureza, aleaciones en diferentes formas y otros subproductos. El procesamiento de estos concentrados genera los residuos sólidos tales como: jarosita, goetitas y relaves de flotación, los cuales son transportados en forma de pulpa hasta las pozas de jarosita y goetitas respectivamente. En vista del cierre por colmatación de la poza N°5, en el año 2013 se construyó la Poza N°6, entre las cotas 485 m.s.n.m (cota de fondo) y la cota 522 m.s.n.m (cota corona de dique), considerando taludes interiores y exteriores 2H:1V, con una capacidad estimada de 3.4 millones de metros cúbicos. Para lo cual, es necesario adecuar el sistema de bombeo existente que viene de la Planta (450 m.s.n.m) hacia la poza N° 5 (490 m.s.n.m) con una impulsión desde esta hasta la corona de la poza N° 6. / Trabajo de suficiencia profesional
14

Diseño hidráulico de la tubería de presión de la Central Hidroeléctrica La Koya

Carquin Chávez, Karla Genifer January 2014 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Muestra los cálculos realizados con el fin de realizar el correcto diseño hidráulico de la tubería de presión de la Central Hidroeléctrica La Koya, que operará con un caudal de diseño de 3.5 m 3 /s, con una caída bruta de 272.21m. y con una potencia instalada total de 7,662 KW. Como parte de los estudios básicos, se realizaron los levantamientos topográficos, el estudio hidrológico en los puntos de captación; y el estudio geológico-geotécnico del área del proyecto. El cálculo de la tubería se ha realizado según el código ASME sección VIII, divisiones 1 y 2; y en base a acero ASTM A-36, sin embargo, se recomienda que de acuerdo a las normas existentes, se deba hacer el replanteo en obra revisando el diseño y la topografía del terreno. / Trabajo de suficiencia profesional
15

Influencia de la variabilidad de parámetros de diseño en uniones con juntas mecánicas, para aplicaciones en codos de radio mayor de servicio de pulpa minera

Peñaloza Arraya, Gustavo Arturo 13 April 2021 (has links)
El presente trabajo de investigación permite establecer un modelo analítico lineal de una junta mecánica semirrígida Victaulic estilo 77, utilizada para unir codos de radio mayor (1.5D, 3D, 5D) con tuberías rectas de acero al carbono en servicios de transporte a presión de pulpa minera. En la industria minera peruana el traslado de pulpa mediante tuberías es ampliamente utilizado, permitiendo aislar la pulpa de entornos sensibles. Sin embargo, la pulpa genera abrasión y consecuentemente desgaste en cambios de dirección, especialmente en codos. El reemplazo de estos últimos elementos casi siempre se realiza en parada de planta donde el tiempo para su sustitución es limitado. El presente trabajo, mediante el modelo antes descrito, permite garantizar un diseño de disposiciones de tuberías confiables bajo la norma ASME B31.3, donde es posible utilizar codos con uniones Victaulic estilo 77 sin ningún tipo de soporteria para algunos casos presentados, ahorrando tiempo valioso en el desmontaje y montaje. Gracias al modelo se puede establecer el nivel de flexibilidad de este tipo de juntas comparando su comportamiento con uniones de tubería rígida y flexible, lo que permite concluir que este tipo de conexión se apega más al comportamiento de una unión flexible, próxima a un tipo de unión articulada. Adicionalmente, con los resultados se obtienen recomendaciones de ubicación y cantidad de soportes para tuberías rectas e instalaciones que involucran codos de radio superior. Estas recomendaciones permiten diseñar los soportes estructurales típicos donde realmente son necesarios.
16

Diseño de metodología para el análisis de flexibilidad en sistemas de tuberías

Rentería Vidaurre, Marcelo 01 June 2015 (has links)
El análisis de flexibilidad es una de las disciplinas del diseño de sistemas de tuberías, se realiza en la etapa final de diseño y comprende principios de concentración de esfuerzos, expansiones térmicas y deformaciones elásticas. Este análisis es crítico en aplicaciones donde el fluido a transportar trabaja a condiciones extremas, como plantas térmicas y generadoras de energía, donde el sistema está sometido a altos gradientes de temperatura que conllevan a la generación de tensiones debido a expansiones o contracciones térmicas. El análisis teórico es de carácter limitativo debido el comportamiento aleatorio del sistema frente a ciertas condiciones de trabajo Por esta razón, los diseñadores optan por la utilización de softwares de análisis como CAEPIPE, CEASAR II, ANSYS, entre otros. Estas herramientas ofrecen resultados confiables; sin embargo, son vistos como “cajas negras”, donde el usuario manipula las variables de entrada. La teoría detrás de estas herramientas de cálculo, muchas veces, son ignoradas por los usuarios. Este trabajo apunta a desarrollar los principios teóricos utilizados para realizar este tipo de análisis, ofrecer herramientas de cálculo sencillas para analistas e investigadores independientes sin acceso a softwares de diseño y mostrar elementos de alivio de tensiones ofrecidos en el mercado actual. La estructura de la trabajo consiste en cuatro capítulos, donde se desarrollarán los principios teóricos básicos de la generación de esfuerzos; el desarrollo de la metodología de diseño de los códigos según ASME; tipos, principios de funcionamiento y criterios de selección de soluciones constructivas para aliviar las tensiones generadas; y, finalmente, el desarrollo de un ejemplo de cálculo que ponga en práctica los conceptos vertidos en los capítulos anteriores, así como, la presentación de casos comunes que complementen las nociones básicas para brindar flexibilidad a sistemas de tuberías.
17

Simulación numérica de un flujo de agua a través de una válvula tipo mariposa de doble excentricidad

Villarroel Quinde, Luis Felipe 18 November 2015 (has links)
Las válvulas mariposa son componentes muy utilizados para el transporte de fluidos a través de tuberías. Dentro de estas válvulas, destacan las válvulas mariposas de doble excentricidad por tener ciertas ventajas como por ejemplo la reducción del desgaste de su sellado en comparación con las válvulas mariposas clásicas. Sin embargo, su asimetría origina un comportamiento más crítico en cuanto a las características hidráulicas del flujo, como son: la pérdida de carga, la distorsión del perfil de velocidades y el riesgo a la cavitación. Como es usual utilizar estas válvulas para control on-off de flujos, se desean bajas pérdidas de carga en su posición totalmente abierta. Cuando estas válvulas se sitúan directamente en el ingreso de turbomáquinas, es importante conocer el grado de distorsión del perfil de velocidades que entra en la máquina ya que ésto modifica los ángulos de ataque del flujo con los álabes y con ello el punto de operación. Y si se opera con presiones bajas también se debe considerar el riesgo de cavitación en partes de la válvula donde se eleve localmente la velocidad. Son estas tres características las que se estudiarán en una válvula mariposa previamente diseñada en la PUCP, con el fin de mejorar la geometría original y con ello su comportamiento hidráulico. Idealmente, se deben realizar ensayos experimentales para conocer el comportamiento hidráulico, pero estos métodos generalmente resultan muy costosos. Una alternativa utilizada hoy en día para la optimización de productos es el estudio computacional CFD (Computational Fluid Dynamics) el cual tiene ciertas ventajas, ya que entrega la información de todos los puntos del dominio y permite realizar cambios en la geometría o en el flujo de forma rápida y menos costosa. En el presente trabajo se realiza el análisis CFD de una válvula mariposa de doble excentricidad con un diámetro nominal de 610mm, en posición completamente abierta con un caudal aproximado de agua de 1 m3/s a 10ºC lo que implica una velocidad media en la tubería de aproximadamente 3.5 m/s. Para ello se utilizó el programa ANSYS CFX 14.0 y se empleó el modelo de turbulencia SST. Luego, se realizó una modificación del diseño original para obtener un diseño alternativo el cual es incluso un 2% más ligero. Lo más importante fue que se consiguió una reducción del 38.3% del coeficiente de pérdidas del diseño original y se aumentó un 40.4% la resistencia a la cavitación del diseño original. Sin embargo, al igual que en el diseño original, el flujo recién comienza a recuperar la forma que tenía antes de ingresar a la válvula después de 14 diámetros nominales aguas abajo de la misma. / Butterfly valves are components used for the transport of fluids through pipes. Among these valves, double eccentric butterfly valves have certain advantages, for example the reduction of wear in the sealing system compared to classic butterfly valves. However, its asymmetry originates some problems in the hydraulic characteristics of the flow such as: pressure loss, distortion of the velocity profile and the risk of cavitation. It is usual to use these valves in the control on-off of flows and because of that, minimum losses are desired when the valves are fully opened. When these valves are located directly at the inlet of turbomachinery, it is important to know the degree of distortion of the velocity profile that enters the machine because this can modify the angles of attack of the flow with the blades and thus the point of operation. And if the valve operates with low pressures, it will be necessary to study the risk of cavitation in the regions of the flow with high velocities. These three characteristics are going to be studied in a butterfly valve previously designed at PUCP, in order to improve the original geometry and its hydraulic behavior. Ideally, experimental methods are required in order to know the hydraulic behaviour, but these methods are usually very expensive. An alternative used today for the optimization of products is the computational study CFD (Computational Fluid Dynamics), which has certain advantages, since it gives information of all the points of the domain and allows the researcher to make fast and inexpensive changes in geometry or flow conditions. In this work, a CFD analysis of a double eccentric butterfly valve is done. The nominal diameter of the valve was 610mm and the valve was fully opened. Its nominal flow was approximately 1 m3/s of water at 10 °C which implied a mean velocity of the flow of 3.5 m/s. The CFD simulation was done using ANSYS CFX 14.0 and the SST turbulence model was used. Then, a modification of the original design was made in order to obtain an alternative design which was 2% lighter. The most important achievement was that the alternative design had a reduction of 38.3% of the loss coefficient of the original design and had an increased of 40.4% of the cavitation resistance of the original design. However, the same as the original design, the flow started to achieve a uniform velocity profile after 14 nominal diameters, downstream of the valve.
18

Evaluación de los factores de intensificación de esfuerzo SIF en accesorios laterales no reforzados de tuberías para relave minero

Morales Ortiz, Jorge Arturo 26 June 2017 (has links)
En este proyecto de tesis, se propone obtener los SIF de un accesorio lateral con ángulo entre ramal y cabezal de 30°, 45°, 60°, 75° y 90°; el mismo que no está reforzado y no estandarizado, fabricado con tubería de acero al carbono ASTM A53 grado B, con soldadura por arco eléctrico con penetración completa, mediante el desarrollo de un modelo matemático complementado con simulaciones numéricas y calibrado con ensayos existentes en la bibliografía [9]. Esto permite la elaboración de una herramienta de selección y diseño, que muestre los SIF para una variedad de geometrías no normadas de accesorios laterales propuestos en este proyecto de tesis. Además, se propone evaluar su variación respecto a parámetros geométricos establecidos acordes a la práctica. / Tesis
19

Dynamic and algebraic observer design for leak detection, size estimation and localization in water pipe systems

Russmann, Julius Paul 06 November 2023 (has links)
En esta tesis se aplican por primera vez métodos basados en modelos sin discretización espacial para detectar y localizar fugas en una planta piloto de transporte de fluidos. Basado en un modelo matemático que describe la dinámica de fluidos dentro de la tubería de agua mediante dos ecuaciones diferenciales parciales que son hiperbólicas, lineales, unidimensionales y acopladas, se deriva y diseña tanto un observador dinámico como algebraico. El diseño del observador dinámico combina un enfoque de Luenberger con una transformación de backstepping para demostrar la estabilidad asintótica del error del observador. Como consecuencia, el observador resulta en un sistema dinámico de dos sistemas diferenciales parciales hiperbólicos acoplados. Por el contrario, el diseño del observador algebraico aplica el método de las funciones de modulación para convertir el modelo matemático en problemas auxiliares que también son dados por ecuaciones diferenciales parciales. Los problemas auxiliares se pueden resolver fuera de línea, tal que para estimar el tamaño y la posición de la fuga en línea se tienen que resolver solamente ecuaciones algebraicas input-output. Se enfatiza que ambos esquemas de observación se derivan directamente del modelo matemático sin discretización espacial. Por lo tanto, esta tesis aborda la brecha de investigación con respecto a métodos de detección y localización de fugas que sean basados en un modelo matemático y que no requieren una discretización espacial del sistema. En simulaciones comparativas, se evalúa el desempeño de ambos observadores para una tubería de agua ejemplar en diversas condiciones de operación, por ejemplo, el tamaño de la fuga, la posición de la fuga, el caudal de entrada y el ruido de medición. Se compara la precisión de los esquemas de observación, y se verifica la capacidad en tiempo real de ambos algoritmos. Finalmente, la dinámica y el observador algebraico se utilizan para estimar el tamaño y la posición de la fuga para una planta piloto de transporte de fluidos instalada en el laboratorio de Ingeniería de Control Avanzado en la PUCP. Se revela que, al contrario de la suposición de un modelo lineal para la perdida por fricción, las pérdidas por fricción dependen cuadráticamente del caudal tal que un modelo no lineal describa con mayor exactitud la dinámica del fluido de la planta piloto. Sin embargo, se ha demostrado que para las fugas que surgen cerca de la salida de la tubería, ambos observadores estiman la posición de la fuga con desviaciones inferiores al 5% y logran la precisión deseada. Además, se ha demostrado que una extensión del observador dinámico hacia el modelo no lineal permite localizar la fuga con desviaciones inferiores al 5%, independientemente de la posición de la fuga. / The present work utilizes for the first time model-based late lumping leak detection methods to detect and localize leakage in a real water pipe. Based on a mathematical model that describes the fluid dynamics inside the water pipe by two coupled linear one dimensional hyperbolic partial differential equations, a dynamic and an algebraic leakage observer are designed. The dynamic observer design combines a Luenberger ansatz with a backstepping transformation to prove the asymptotic stability of the observer error and results in a dynamic system of two coupled hyperbolic partial differential systems. Contrary to that, the algebraic observer design applies the modulating function method to convert the mathematical model into offline solvable auxiliary problems and algebraic input-output equations that are resolved online to estimate the leak size and the leak position. It is emphasized that both observer schemes are derived directly from the mathematical model without spatial discretization. Thereby, this thesis addresses the research gap regarding model-based late lumping leak detection and localization techniques. In comparative simulations, the performance of both observer schemes is evaluated for an exemplary water pipe under various operating conditions, e.g., w.r.t. the leak size, the leak position, the inlet flow rate and the measurement noise. The accuracy of the observer schemes is compared, and the real-time capability of both algorithms is verified. Finally, the dynamic and the algebraic observer are utilized to estimate the leak size and the leak position for a pilot fluid transport plant installed in the laboratory of Advanced Control Engineering at the PUCP. It is revealed that, in opposite to the model assumption of linear friction losses, the friction losses depend quadratically on the flow rate such that a nonlinear model describes the flow dynamics of the pilot plant more exactly. However, it is shown that for leaks occurring near to the outlet of the pipe, both observers estimate the leak position with deviations of under 5 % and reach thereby the desired accuracy. Furthermore, it is demonstrated that an extension of the dynamic observer towards the nonlinear model permits localizing the leak with deviations of under 5 % regardless of its position. / Die vorliegende Arbeit verwendet erstmals räumlich undiskretisierte modellbasierte Methoden zur Erkennung und Lokalisierung von Leckagen in einer realen Wasserleitung. Basierend auf einem mathematischen Modell, das die Strömungsdynamik im Rohr durch zwei gekoppelte lineare eindimensionale hyperbolische partielle Differentialgleichungen beschreibt, werden ein dynamischer und ein algebraischer Leckagebeobachter entworfen. Der dynamische Beobachterentwirf kombiniert einen Luenberger-Ansatz mit einer Backstepping-Transformation, um die asymptotische Stabilität des Beobachterfehlers nachzuweisen und resultiert in einem dynamischen System aus zwei gekoppelten hyperbolischen partiellen Differentialgleichungen. Im Gegensatz dazu verwendet der algebraische Beobachterentwurf die Modulationsfunktionsmethode, um das mathematische Modell in offline lösbare Hilfsprobleme sowie algebraische Eingangs-Ausgangs-Gleichungen zu überführen, die online gelöst werden, um die Leckgröße und die Leckageposition zu schätzen. Es wird hervorgehoben, dass beiden Beobachter direkt aus dem mathematischen Modell ohne räumliche Diskretisierung abgeleitet sind. Die vorliegende Arbeit adressiert damit eine existierende Forschungslücke hinsichtlich modellbasierter Leckagelokalisierung. In vergleichenden Simulationen wird die Performance beider Beobachter für eine exemplarische Wasserleitung unter unterschiedlichen Betriebsbedingungen untersucht, z. B. hinsichtlich der Leckgröße, der Leckposition, des Volumenstroms am Einlass und dem Messrauschen. Die Genauigkeit der Beobachter wird verglichen und die Echtzeitfähigkeit beider Algorithmen überprüft. Anschließend werden der dynamische und der algebraische Beobachter verwendet, um die Leckgröße und die Leckageposition für eine Pilotanlage, die im Labor für Regelungstechnik an der PUCP installiert ist, zu schätzen. Es zeigt sich, dass die Reibungsverluste entgegen der Modellannahme quadratisch von der Strömungsgeschwindigkeit abhängen, sodass ein nichtlineares Modell die Strömungsdynamik der Pilotanlage genauer beschreibt. Es zeigt sich jedoch, dass bei Leckagen in der Nähe des Rohrauslasses beide Beobachter die Leckageposition mit Abweichungen von unter 5 % schätzen und damit die gewünschte Genauigkeit erreichen. Abschließend wird gezeigt, dass eine Erweiterung des dynamischen Beobachters hin zum nichtlinearen Modell die Lokalisierung des Lecks mit Abweichungen von weniger als 5 % unabhängig von seiner Position ermöglicht.
20

Estudio de los efectos de la dilatación térmica en tuberías mediante simulación numérica

Vásquez Ponce, Martín Javier 13 July 2015 (has links)
Esta tesis establece un procedimiento de análisis de las tensiones generadas por la dilatación térmica en tres arreglos de tuberías: una tubería simple enterrada, una tubería con un cambio de dirección de 90° y una tubería enterrada con un cambio de dirección de 90°. Para darle solución a cada uno de los casos se analizan los esfuerzos térmicos por dos vías diferentes: la simulación numérica mediante el programa ANSYS y por teorías de resistencia de materiales. El planteamiento de estos dos métodos da la ventaja de corroborar los valores obtenidos verificando que sean similares entre sí y a la vez analizar los comportamientos complejos de ciertos parámetros en la tubería. Para plantear el análisis por resistencia de materiales se explica los siguientes conceptos: dilatación térmica, esfuerzo térmico, longitud virtual entre apoyos, modelo analítico del terreno, flexión en vigas, vigas sobre fundación elástica y teorías de falla. Junto con los conocimientos anteriores es posible, para cada caso, simplificar el modelo teórico y así obtener valores de tensión crítica por medio del procedimiento realizado con los conceptos estudiados. Luego se plantea el estudio por simulación numérica usando modelos lineales para las tuberías y de resortes para el terreno. Se confirma la validez de la simulación como método de análisis al contratar valores con el planteamiento teórico y obtener porcentajes de similitud del grado del 83 – 98 %. Además es posible analizar con mayor profundidad cada caso ya que la simulación da las herramientas suficientes para ver el comportamiento de la dilatación y fuerza a lo largo de la tubería y obtener los esfuerzos máximos (que varían de 35 a 166 MPa según el arreglo de tubería) para realizar un análisis de fallas.