• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 2
  • Tagged with
  • 9
  • 9
  • 9
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Besign-directed measurements of B1 heterogeneity and spin-lattice relaxation for 8 Tesla MRI

Mitchell, Chad A. 12 October 2004 (has links)
No description available.
2

Dynamic Contrast Enhanced Magnetic Resonance Imaging at High and Ultra-high Fields

Liang, Jiachao January 2008 (has links)
No description available.
3

Évaluation des effets biologiques des ondes radiofréquences : cas des ondes pulsées utilisées en IRM et des ondes millimétriques / Evaluation of biological effects of radio waves : the case of pulsed waves used in MRI and millimeter wave

Soubere Mahamoud, Yonis 08 November 2013 (has links)
Des études in vitro ont été menées pour évaluer les effets biologiques potentiels de deux types d'ondes radiofréquences. Dans une première partie, nous avons étudié les ondes radiofréquences (300 et 500 MHz) utilisées en imagerie médicale à haute résolution (IRM). Ces ondes sont en régime impulsionnel (de l'ordre de la milliseconde) et avec des puissances crêtes élevées (E= 1.8 kV/m). Toutefois, il n'existe actuellement aucune donnée dans la littérature sur l'impact biologique éventuel de ce type de signaux. Dans ce travail de thèse des cellules gliales humaines (U251 MG) en culture ont été exposées pendant 45 minutes, ou 2 heures, en condition athermique, et plusieurs analyses biologiques ont été réalisés : expression génique d'une batterie de gènes biomarqueurs du stress cellulaire et analyse par microscopie de l'intégrité cellulaire. Quel que soit le test utilisé, les résultats ont toujours été négatifs. Ceci montre qu'aucun stress cellulaire n'a eu lieu lors de l'exposition des cellules à une onde électromagnétique de 300 ou 500 MHz, de forte puissance crête. La seconde partie de ce travail de thèse porte sur l'évaluation des effets des ondes millimétriques (OMM) à 60,4 GHz, en cas de stress énergétique. Nous avons étudié l'impact de l'exposition aux OMM, en présence ou en absence de 2-déoxy-glucose, sur la production d'ATP, le potentiel redox (NADPH) et l'expression génique. Par une approche transcriptomique, nous avons observé qu' un traitement au 2-déoxy-glucose, induit une forte réponse cellulaire. La co-exposition aux OMM modifie faiblement cette réponse génique (4 gènes sur 523 semblent être différentiellement exprimés). Par contre, l'exposition est sans effet sur le potentiel redox ou sur la production d'ATP. / In vitro studies were conducted to evaluate the biological effects of two types of radiofrequency waves. In the first part, we studied the radiofrequency (300 and 500 MHz) used in medical imaging at high resolution (MRI). These radio waves are pulsed (millisecond) with strong peaks power (E = 1.8 kV/m). However, there is currently no data in the literature, on the potential biological impact of such signals. This thesis examines whether exposure to this type of signal, may or may not, trigger a cellular stress. Human glial cells (U251 MG) in culture were exposed for 45 minutes or 2 hours in athermal conditions, and several biological tests were performed: gene expression of stress biomarkers or cell integrity by Cellomics technology. Whatever the test used, no significant modification was observed between the control and the exposed cells. This strongly suggests that no cellular stress occurred during the exposure of cells to high peak power RF pulses. The second part of this thesis specifically examines the effect of millimeter waves (MMW) at 60.4 GHz in cells deprived from glucose. We investigated whether exposure to MMW, in the presence or absence of 2-deoxy-glucose has an effect on ATP production, redox potential (NADPH) and gene expression. We found no genes differentially expressed between the sham control and the exposed cells. In contrast, when cells are submitted to a metabolic stress (treated with 2dG), we found that MMW radiation significantly modifies the gene expression (4 genes out of 523 are differentially expressed). However, OMM exposure has no effect on the redox potential or ATP production.
4

1H and 31P NMR Spectroscopy for the study of brain metabolism at Ultra High Magnetic Field from Rodents to Men / Spectroscopie RMN du 1H et 31P pour l'étude du métabolisme cérébral à très haut champ magnétique du rongeur à l'homme

Lopez Kolkovsky, Alfredo L. 08 June 2015 (has links)
La Spectroscopie RMN (SRMN) du 1H et du 31P permet de détecter et de mesurer in vivo de façon non-invasive la concentration de composés biologiques qui sont pertinents à l’étude des aspects variés du métabolisme cérébral comme la neurotransmission (glutamate, GABA), la densité neuronale (N-acetyl-aspartate) et gliale (myo-inositol) ou le métabolisme énergétique (phosphocreatine, ATP), entre autres. Ainsi, l’analyse des profils biochimiques permet d’étudier longitudinalement l’évolution de la physiologie cérébrale en conditions pathologiques ou normales. Par ailleurs, à ultra-haut champ magnétique la SRMN bénéficie d’une sensibilité et d’une résolution spectrale accrues, maximisant l’information métabolique exploitable. Au cours de cette thèse, nous nous sommes surtout intéressés à l’étude du vieillissement cérébral normal. Une étude longitudinale en 1H et 31P a été menée in vivo à 17.2 Tesla afin de suivre les altérations métaboliques pendant 14 mois chez deux cohortes de rats Dark Agouti âgés d’un mois et 8 mois au départ de l’étude. Les concentrations ainsi que les temps de relaxation T1 et T2 de plus de 20 métabolites ont été mesurés jusqu’à l’âge de 22 mois. Nous avons notamment observé une augmentation des concentrations de myo-inositol et des macromolécules dans les 4 volumes d’intérêt (VOI) étudiés. Dans le VOI Main, comprenant principalement du cortex mais aussi du corps calleux et de l’hippocampe, ces changements métaboliques ont été accompagnés par une augmentation des niveaux de glutamine et de composés contenant de la choline (tCho). Ces observations sont cohérentes avec une possible neuro-inflammation modéré au cours du vieillissement. Aucun changement du NAA a été observé sur le Main VOI, thalamus et putamen caudé (striatum). Additionnement, une réduction des temps T2 pour le NAA total, la tCho et les macromolécules a été observée, en accord avec une altération du milieu cellulaire et une accumulation de fer dans les tissus avec l’âge. Etonnamment, nous avons observé un effet corrélé avec le nombre d’examens RMN, qui a été fortement manifesté par une augmentation significative des temps T1 de nombreux métabolites.Un deuxième axe de travail pendant cette thèse a été la mise en place des outils méthodologiques nécessaires à la réalisation des études par SRMN du 1H et du 31P à 7 Tesla chez l’homme. Des séquences d’imagerie spectroscopique 2D ont été développées pour obtenir des cartes de concentration des métabolites 31P et 1H respectivement par la sélection d’une coupe ou bien d’un voxel par écho-stimulé. Un schéma de suppression d’eau WET a été optimisé pour son application à 7 T. Des modes d’excitation et de saturation du signal extérieur (OVS) en « anneau » ont été implémentés avec la méthode de transmission parallèle pour son application en imagerie spectroscopique 1H par l’optimisation des configurations statiques d’excitation ou « shimming-B1 ». Cette approche a permis d’appliquer des champs d’excitation plus homogènes et de réduire le dépôt d’énergie chez le sujet par rapport à l’utilisation des bandes OVS classiques. Des expériences in vitro ont été menées pour démontrer leur faisabilité. Enfin, un module de saturation BISTRO a été implémenté pour l’acquisition in vivo de cartes métaboliques en 31P. L’efficacité du module BISTRO a été démontrée et ce module peut être adapté pour des expériences 31P de transfert d’aimantation, ouvrant la voie de l’étude du métabolisme énergétique cérébral chez l’homme à très haut champ magnétique. / 1H and 31P nuclear magnetic resonance spectroscopy allows to detect and to measure in vivo and non-invasively the concentrations of biologically relevant compounds associated to metabolic processes such as neurotransmission (glutamate, GABA), neuronal and glial density (N-acetyl-aspartate, myo-inositol) and energetic metabolism (phosphocreatine, ATP) among others. Knowledge of the biochemical profile provides a mean to evaluate the metabolic state of the brain in pathological cases or in evolving physiological conditions, such as aging. Yet, the neural basis of age-related cognitive dysfunction in normal brain aging remains to be elucidated and it has been shown to develop at different rates depending on the structural region.At ultra-high magnetic fields, magnetic resonance spectroscopy (MRS) benefits from an increased signal-to-noise ratio and a higher chemical shift dispersion, resulting in an increased sensitivity and spectral resolution. To exploit these advantages, 1H and 31P longitudinal studies were carried out in vivo at 17.2 Tesla in the aging rat brain to evaluate the progressive metabolic changes within the same individuals from the ages of 1 to up to 22 months of age using two rat cohorts with 1 and 8 months of age at the beginning of the study. For the 1H MRS studies, T1 and T2 metabolite relaxation times were measured at each exam in order to control age-related variations and to calculate absolute metabolite concentrations. 1H neurochemical profiles from four volumes of interest (VOI) in the brain were studied, revealing a progressive increase in myo-inositol and macromolecule content throughout the brain. In our main VOI composed mostly of cortex but also of corpus callosum and hippocampus, increased levels of choline-containing compounds (tCho) and glutamine were also observed, suggesting a mild neuroinflammation. No changes in NAA were observed in our main VOI, the thalamus or the caudate putamen (striatum). T2 decreases were observed with age for total NAA, tCho and macromolecules. Notably, unexpected effects correlated with the number of NMR exams were observed, the most prominent effect being an increase of the T1 relaxation times of the majority of metabolites.The second axis of the work done during this thesis was to set up an experimental framework for MR spectroscopic imaging (MRSI) studies at 7 Tesla in the human brain. 2D MRSI pulse sequences were developed for the acquisition of 31P and 1H metabolite maps using either slab selection or STEAM localization, respectively. A WET water suppression scheme was numerically optimized for its application at 7 T. Static B1-shimming configurations were implemented to reduce the inhomogeneity of the excitation field in the volume of interest and to generate outer-volume suppression (OVS) “ring” modes to saturate the signal in the periphery of the head. This approach allows to reduce the energy deposition in comparison to conventional OVS bands. Experiments were done in vitro showing their feasibility. The performance of standard OVS bands was also compared to a B1-insensitive train to obliterate signal (BISTRO) scheme in vivo using a double-tuned 1H/31P phased-array coil in a single-channel configuration for transmission. The demonstrated suppression efficacy of BISTRO opens the way for its use as a frequency-selective pre-saturation module for future 31P magnetization transfer experiments for the study of brain energy metabolism at very high magnetic field.
5

Antennes reseaux pour la transmission parallele en irm a ultra haut champ : conception, réalisation et stratégie de pilotage / Phased Array RF Coils for Parallel Transmission in Ultra High Field MRI : design, Construction and Driving Concept

Ferrand, Guillaume 19 September 2011 (has links)
Le projet Iseult-Inumac mené au sein d’un consortium franco-allemand vise à développer les techniques associées à l’imagerie par résonance magnétique à ultra haut champ, notamment à travers la construction d’un imageur à 11,7 teslas. La résolution accrue du nouvel imageur devrait apporter une meilleure compréhension du système nerveux et de ses dysfonctionnements pour aboutir à un dépistage plus précoce des pathologies telles que la maladie d’Alzheimer, les accidents vasculaires cérébraux ou les tumeurs.La principale difficulté technique du projet, en dehors de la construction de l’aimant statique, réside dans la capacité d’émettre une onde électromagnétique d’amplitude uniforme dans tout le cerveau du patient : problème de l’inhomogénéité de B1 (ou radiofréquence). Une solution proposée consiste à utiliser une antenne réseau à transmission parallèle et des séquences d’excitation IRM spécifiques dites de compensation.Cette thèse se concentre sur la conception des antennes réseaux à transmission parallèle pour l’IRM à 7 et 11,7 T. Un prototype à 8 canaux indépendants utilisant une technologie innovante de résonateurs linéaires est présentée pour l’IRM 7 T. Il a été conçu par la simulation numérique. Un protocole de validation a été développé pour la caractérisation et l’analyse des performances des antennes réseaux. Le succès de cette validation a permis de développer par la simulation une nouvelle antenne à 12 canaux et une stratégie de pilotage innovante permettant de n’utiliser que 8 chaînes de pilotage au lieu de 12. Enfin, la même méthodologie a été appliquée pour concevoir et prédire les performances d’une antenne réseau à 11,7 T. / The Iseult-Inumac project led by a franco-german consortium aims at developing the ultra-high field MRI technologies, especially with the building of an 11.7 tesla scanner. The high resolution of this new scanner may improve the understanding of human nervous system and its dysfunctions in order to detect pathologies like the Alzheimer disease, strokes or tumors earlier.The biggest technical difficulty, besides the building of the static magnet itself, lies in the emission of a uniform electromagnetic wave in the entire brain of the patient. It is usually referred as to B1 (or RF) inhomogeneity issues. A solution consists in using a phased array RF coil and specific MRI sequences for shimming in a parallel transmit approach.This thesis deals with the study of parallel transmit phased arrays RF coils for 7 T and 11.7 T MRI. An eight independent channels prototype-coil that uses a new planar strip array technology is described for 7 T MRI. It was designed based on numerical simulation. A validation methodology has been developed for characterization and performance analysis of transmit phased arrays. After a successful validation of this first prototype, a more efficient 12-channel coil and a new driving strategy that only requires 8 driving channels instead of 12 were designed. Finally, the same methodology was applied to a phased array RF coil for 11.7 T MRI.
6

Parallel transmission for magnetic resonance imaging of the human brain at ultra high field : specific absorption rate control & flip-angle homogenization

Cloos, Martijn Anton Hendrik 17 April 2012 (has links) (PDF)
The focus of this thesis lies on the development, and implementation, of parallel transmission (pTx) techniques in magnetic resonance imaging for flip-angle homogenization throughout the human brain at ultra-high field. In order to allow in-vivo demonstrations, a conservative yet viable safety concept is introduced to control the absorbed radiofrequency (RF) power . Subsequently, novel methods for local SAR control and non-selective RF pulse-design are investigated. The impact of these short and energy-efficient waveforms, referred to as kT-points, is first demonstrated in the context of the small-tip-angle domain. Targeting a larger scope of applications, the kT-points design is then generalized to encompass large flip angle excitations and inversions. This concept is applied to one of the most commonly used T1-weighted sequences in neuroimaging. Results thus obtained at 7 Tesla are compared to images acquired with a clinical setup at 3 Tesla, validating the principles of the kT-points method and demonstrating that pTx-enabled ultra-high field systems can also be competitive in the context of T1-weighted imaging. Finally, simplifications in the global design of the pTx-implementation are studied in order to obtain a more cost-effective solution.
7

Post mortem inference of the human brain microstructure using ultra-high field magnetic resonance imaging with strong gradients / Etude de la microstructure du cerveau humain par imagerie post mortem à très haut champ magnétique et forts gradients

Beaujoin, Justine 18 December 2018 (has links)
L’ambition des très hauts champs magnétiques (≥ 7T) à forts gradients (≥ 300mT/m) est de dépasser la résolution millimétrique imposée à plus bas champ pour atteindre l’échelle mésoscopique en neuroimagerie. Etudier le cerveau à cette échelle est essentiel pour comprendre le lien entre fonction et substrat anatomique. Malgré les progrès réalisés sur les aimants cliniques à 7T, il n’en est pas de même des gradients. Cette thèse vise à cartographier le cerveau humain à l’échelle mésoscopique via l’étude de pièces anatomiques post mortem. Une approche alternative a été choisie, reposant sur l'utilisation d'imageurs précliniques à très hauts champs (7T et 11.7T) et forts gradients (780mT/m). Après une première étape de préparation (extraction et fixation) opérée au CHU de Tours, une pièce anatomique complète a été scannée à 3T, avant découpe de l’hémisphère gauche en sept blocs. Un protocole d’acquisition IRM ciblant une résolution mésoscopique a ensuite été mis en place à 11.7T. Ce protocole, incluant des séquences anatomiques, relaxométriques, et de diffusion, a été validé à l’aide de deux structures clé: un hippocampe et un tronc cérébral. Les données anatomiques et de diffusion acquises à une résolution mésoscopique sur l’hippocampe ont permis de segmenter ses sous-champs, d’extraire le circuit polysynaptique et d’observer l’existence d’un gradient de connectivité et de densité neuritique positif dans la direction postéro-antérieure de l’hippocampe. L’utilisation de modèles avancés d’étude de la microstructure a également révélé l’apport de ces techniques pour la segmentation de l’hippocampe, les cartes de densité neuritique révélant les trois couches des champs ammoniens. Un tronc cérébral a ensuite été scanné, avec une résolution atteignant la centaine de micromètres. Une segmentation de 53 de ses 71 noyaux a été réalisée au sein du CHU de Tours, permettant d’établir la cartographie IRM du tronc cérébral humain la plus complète à ce jour. Les principaux faisceaux de la substance blanche ont été reconstruits, ainsi que les projections du locus coeruleus, structure connue pour être atteinte dans le maladie de Parkinson. Forts de ces résultats, la campagne d'acquisition de l'hémisphère gauche, d’une durée de 10 mois, a été initiée. Le protocole d’acquisition à 11.7T intègre des séquences anatomiques (100/150µm) ainsi que des séquences d'imagerie 3D pondérées en diffusion (b=1500/4500/8000 s/mm², 25/60/90 directions) à 200µm. Des acquisitions complémentaires réalisées à 7T comprenant des séquence d’écho de spin rapide avec inversion-récupération ont par ailleurs permis d’étudier la myéloarchitecture du cortex cérébral et d’identifier automatiquement sa structure laminaire. Un nouveau modèle de mélange de Gaussiennes a été développé, intégrant les informations myéloarchitecturales issues de la cartographie T1 et les informations cytoarchitecturales issues de l’imagerie de diffusion. Il a ainsi pu être démontré que l’utilisation conjointe de ces deux informations permettait de mettre en évidence des couches du cortex visuel, l’information myéloarchitecturale favorisant l’extraction des couches externes et la densité neuritique celle des couches plus profondes. Enfin, l’exploitation des données IRM acquises à 11.7T sur les différents blocs a nécessité la mise en place d’une chaîne de prétraitements pour corriger les artéfacts d’imagerie et reconstruire l’hémisphère entier à l’aide de stratégies de recalage difféomorphe avancées. L’objectif de ce projet est l’obtention d’un jeu de données IRM de très haute résolution spatio-angulaire de l’hémisphère gauche. Ce jeu de données anatomique et de diffusion unique permettra à terme de constituer un nouvel atlas IRM mésoscopique de la structure, de la connectivité et de la cytoarchitecture du cerveau humain. / The aim of ultra-high field strength (≥7T) and ultra-strong gradient systems (≥300mT/m) is to go beyond the millimeter resolution imposed at lower field and to reach the mesoscopic scale in neuroimaging. This scale is essential to understand the link between brain structure and function. However, despite recent technological improvements of clinical UHF-MRI, gradient systems remain too limited to reach this resolution. This thesis aims at answering the need for mapping the human brain at a mesoscopic scale by the study of post mortem samples. An alternative approach has been developed, based on the use of preclinical systems equipped with ultra-high fields (7T/11.7T) and strong gradients (780mT). After its extraction and fixation at Bretonneau University Hospital (Tours), an entire human brain specimen was scanned on a 3T clinical system, before separating its two hemispheres and cutting each hemisphere into seven blocks that could fit into the small bore of an 11.7T preclinical system. An MRI acquisition protocol targeting a mesoscopic resolution was then set up at 11.7T. This protocol, including anatomical, quantitative, and diffusion-weighted sequences, was validated through the study of two key structures: the hippocampus and the brainstem. From the high resolution anatomical and diffusion dataset of the human hippocampus, it was possible to segment the hippocampal subfields, to extract the polysynaptic pathway, and to observe a positive gradient of connectivity and neuritic density in the posterior-anterior direction of the hippocampal formation. The use of advanced microstructural models (NODDI) also highlighted the potential of these techniques to reveal the laminar structure of the Ammon’s horn. A high resolution anatomical and diffusion MRI dataset was obtained from the human brainstem with an enhanced resolution of a hundred micrometers. The segmentation of 53 of its 71 nuclei was performed at the Bretonneau University Hospital, making it the most complete MR-based segmentation of the human brainstem to date. Major white matter bundles were reconstructed, as well as projections of the locus coeruleus, a structure known to be impaired in Parkinson’s disease. Buoyed by these results, a dedicated acquisition campaign targeting the entire left hemisphere was launched for total scan duration of 10 months. The acquisition protocol was performed at 11.7T and included high resolution anatomical sequences (100/150μm) as well as 3D diffusion-weighted sequences (b=1500/4500/8000 s/mm², 25/60/90 directions, 200μm). In addition, T1-weighted inversion recovery turbo spin echo scans were performed at 7T to further investigate the myeloarchitecture of the cortical ribbon at 300µm, revealing its laminar structure. A new method to automatically segment the cortical layers was developed relying on a Gaussian mixture model integrating both T1-based myeloarchitectural information and diffusion-based cytoarchitectural information. The results gave evidence that the combination of these two contrasts highlighted the layers of the visual cortex, the myeloarchitectural information favoring the extraction of the outer layers and the neuritic density favoring the extraction of the deeper layers. Finally, the analysis of the MRI dataset acquired at 11.7T on the seven blocks required the development of a preprocessing pipeline to correct artifacts and to reconstruct the entire hemisphere using advanced registration methods. The aim was to obtain an ultra-high spatio-angular resolution MRI dataset of the left hemisphere, in order to establish a new mesoscopic post mortem MRI atlas of the human brain, including key information about its structure, connectivity and microstructure.
8

A flexible coil array for high resolution magnetic resonance imaging at 7 Tesla / Réseau flexible d'antennes miniatures pour l'imagerie par résonance magnétique haute résolution à 7 Tesla

Kriegl, Roberta 17 December 2014 (has links)
L’imagerie par résonance magnétique (IRM) est un outil d’investigation majeur donnant accès de manière non invasive à des nombreuses informations quantitatives et fonctionnelles. La qualité des images obtenues (rapport-signal-sur-bruit, RSB) est cependant limitée dans certaines applications nécessitant des résolutions spatiales et/ou temporelles poussées. Afin d’améliorer la sensibilité de détection des équipements d’IRM, diverses orientations peuvent être suivies telles qu’augmenter l’intensité du champ magnétique des imageurs, améliorer les performances des systèmes de détection radiofréquence (RF), ou encore développer des séquences d’acquisition et des techniques de reconstruction d’images plus efficaces. La thématique globale dans laquelle s’inscrit cette thèse concerne le développement des systèmes de détection RF à haute sensibilité pour l’IRM à haut champ chez l’homme. En particulier, des antennes auto-résonantes basées sur le principe des lignes de transmission sont utilisées parce qu’elles peuvent être réalisée sur substrat souple. Cette adaptabilité géométrique du résonateur permet d’ajuster précisément sa forme aux spécificités morphologiques de la zone anatomique observée, et ainsi d’augmenter le RSB. La première visée technologique de ce projet concerne le développement, de la conception jusqu’à la mise en œuvre dans un appareil 7 T corps entier, d’un système de détection RF flexible à haute sensibilité, utilisant des antennes miniatures associées en réseau. L’utilisation d’un réseau d’antennes miniatures permet d’obtenir des images sur un champ de vue élargi tout en conservant la haute sensibilité inhérente à chaque antenne miniature. De plus, la technologie de l’imagerie parallèle devient accessible, ce qui permet d’accélérer l’acquisition des images. De surcroît, un nouveau schéma de résonateur de ligne transmission avec un degré de liberté supplémentaire est introduit, ce qui permet de réaliser de grands résonateurs multi-tours pour l’IRM à haut champ. Cette thèse décrit le développement, la mise en œuvre et l’évaluation des nouveaux systèmes de détection RF au moyen de simulations analytiques et numériques, et des études expérimentales. / Magnetic resonance imaging (MRI), among other imaging techniques, has become a major backbone of modern medical diagnostics. MRI enables the non-invasive combined, identification of anatomical structures, functional and chemical properties, especially in soft tissues. Nonetheless, applications requiring very high spatial and/or temporal resolution are often limited by the available signal-to-noise ratio (SNR) in MR experiments. Since first clinical applications, image quality in MRI has been constantly improved by applying one or several of the following strategies: increasing the static magnetic field strength, improvement of the radiofrequency (RF) detection system, development of specialized acquisition sequences and optimization of image reconstruction techniques. This work is concerned with the development of highly sensitive RF detection systems for biomedical ultra-high field MRI. In particular, auto-resonant RF coils based on transmission line technology are investigated. These resonators may be fabricated on flexible substrate which enables form-fitting of the RF detector to the target anatomy, leading to a significant SNR gain. The main objective of this work is the development of a flexible RF coil array for high-resolution MRI on a human whole-body 7 T MR scanner. With coil arrays, the intrinsically high SNR of small surface coils may be exploited for an extended field of view. Further, parallel imaging techniques are accessible with RF array technology, allowing acceleration of the image acquisition. Secondly, in this PhD project a novel design for transmission line resonators is developed, that brings an additional degree of freedom in geometric design and enables the fabrication of large multi-turn resonators for high field MR applications. This thesis describes the development, successful implementation and evaluation of novel, mechanically flexible RF devices by analytical and 3D electromagnetic simulations, in bench measurements and in MRI experiments.
9

Parallel transmission for magnetic resonance imaging of the human brain at ultra high field : specific absorption rate control & flip-angle homogenization / Transmission parallèle pour l’imagerie du cerveau humain par résonance magnétique à très haut champ : contrôle du débit d’absorption spécifique et homogénéisation de l’angle de bascule

Cloos, Martijn Anton Hendrik 17 April 2012 (has links)
L'objectif de cette thèse repose sur le développement et la mise en œuvre des techniques de transmission parallèle (pTx) en Imagerie par Résonance Magnétique pour homogénéiser l’excitation des spins dans le cerveau humain à ultra-haut champ. Afin de permettre des démonstrations in-vivo, un concept de sécurité conservateur mais viable est introduit pour le contrôle de la puissance de la radiofréquence (RF) transmise. Par la suite, de nouvelles méthodes de minimisation du Taux d’Absorption Spécifique local et de conception d’impulsions RF non-sélectives sont investiguées. L’impact de ces impulsions courtes et relativement peu énergétiques, appelées « kT-points », est d'abord démontré dans l’approximation des petits angles de bascule de l’aimantation. Pour cibler un éventail d’applications plus large, la conception de type kT-points est ensuite généralisée en englobant les excitations à grand angle de bascule et les inversions. Cette méthode est appliquée à l'une des séquences pondérées en T1 les plus couramment utilisées en neuro-imagerie. Les résultats ainsi obtenus à 7 Tesla sont comparés à des images acquises avec une configuration clinique à 3 Tesla. Les principes de la méthode sont ainsi validés et démonstration est faite que la transmission parallèle permet aux systèmes à très haut champ d’être aussi compétitifs en imagerie pondérée en T1. Enfin, des simplifications dans la conception globale de la pTx sont étudiées pour un meilleur rapport coût-efficacité des solutions proposées. / The focus of this thesis lies on the development, and implementation, of parallel transmission (pTx) techniques in magnetic resonance imaging for flip-angle homogenization throughout the human brain at ultra-high field. In order to allow in-vivo demonstrations, a conservative yet viable safety concept is introduced to control the absorbed radiofrequency (RF) power . Subsequently, novel methods for local SAR control and non-selective RF pulse-design are investigated. The impact of these short and energy-efficient waveforms, referred to as kT-points, is first demonstrated in the context of the small-tip-angle domain. Targeting a larger scope of applications, the kT-points design is then generalized to encompass large flip angle excitations and inversions. This concept is applied to one of the most commonly used T1-weighted sequences in neuroimaging. Results thus obtained at 7 Tesla are compared to images acquired with a clinical setup at 3 Tesla, validating the principles of the kT-points method and demonstrating that pTx-enabled ultra-high field systems can also be competitive in the context of T1-weighted imaging. Finally, simplifications in the global design of the pTx-implementation are studied in order to obtain a more cost-effective solution.

Page generated in 0.0575 seconds