• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação crítica de ambientes em eselecimentos assistenciais de saúde / Critical assessment of environments in health care eslishments

Araujo, Eliete de Pinho January 2008 (has links)
Made available in DSpace on 2012-09-05T18:23:43Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 331.pdf: 6077221 bytes, checksum: 8dad97e035edb79ff9aeb060bb2fde3d (MD5) Previous issue date: 2008 / Este trabalho apresenta um estudo referente à análise crítica, no sentido decontribuir para a saúde. Foram abordados os conceitos de saúde, direito e leis, assim como a apresentação da legislação pertinente aos temas. Os temas deste estudo foram: o sistemade ar condicionado, os resíduos das processadoras de Raios X e o reúso da água. A idéia de implantar a Estação de Tratamento de Esgoto (ETE), tratando o esgoto sanitário e utilizando as águas recuperadas nas instalações hospitalares e na limpeza, lavagem epequenas obras do hospital é inovadora. Foram estudados o Hospital Estadual Carlos Chagas (HECC), no Rio de Janeiro, o Hospital Regional do Paranoá (HRPA), em Brasília, e o St. Paul Hospital (StPH), em Vancouver, Canadá. O objetivo é fazer uma avaliaçãocrítica de ambientes e das instalações prediais em Eselecimentos Assistenciais de saúde (EAS): analisar o sistema de ar condicionado, nos ambientes climatizados artificialmente;analisar o descarte dos produtos químicos oriundos das processadoras de filmes radiográficos no meio ambiente; propor a implantação do reúso da água proveniente da Estação de Tratamento de Esgoto e sugerir melhorias referentes aos três objetivos citados anteriormente. O método utilizado foi: 1) fazer medições de temperatura do ar e da água nos ambientes climatizados artificialmente e nas máquinas (fan-coil), em diferentes datas, abrangendo as quatro estações climáticas anuais, assim como analisar e propor os materiais de acabamento adequados nas centrais e salas de ar condicionado, verificar a limpeza dos dutos de condução e retorno do ar e analisar os laudos técnicos laboratoriais do ar; 2)verificar o sistema de descarte do produto químico, oriundo das processadoras para o meio ambiente; 3) analisar os espaços disponíveis nos hospitais para implantar a ETE e oreservatório de reúso de água, avaliar as análises do produto e sugerir o reúso nas instalações prediais, conforme os resultados. / Foi utilizada a avaliação pós-ocupação (APO) por meio de questionários aplicados aos usuários / funcionários das unidades estudadas, em diversos períodos do ano. Pelos resultados encontrados, variações internas de temperaturas do ar de 10º C e 12,5º C no HECC, de 11,4º C no HRPA e de 6º C no StPH, os dois hospitais do Brasil necessitam de ajustes no sistema de ar condicionado e o St. PH mostroumelhores condições internas de conforto térmico para o usuário. Fizeram a limpeza dos dutos por meio de robô e outro equipamento. O hospital do Canadá, embora nunca tenha feito limpeza robotizada nos dutos, foi o que melhores condições de conforto ambiental apresentou. Os produtos químicos descartados tiveram resultados diferentes nos trêshospitais. O HECC está em melhores condições seguras de trabalho e para o meio ambiente, e o do Canadá possui um sistema sem revelação de filme radiográfico, pois é digital. Quanto às ETEs, o HECC já a possui, só precisando fazer ajustes, o HRPA não tem, será proposta e é de interesse da Secretaria de Saúde local implantá-la e o StPH não tem e não mostrou interesse em construí-la. Os reservatórios de água de reúso nos dois hospitais brasileiros deverão ser construídos. Foram propostos manuais práticos de implantação e manutenção, além da realização de seminários relativos aos temas nas Secretarias de Saúdedo Rio de Janeiro e do Distrito Federal. / Conclui-se que, em relação aos três temas, os procedimentos adequados e as Normas de Saúde devem ser seguidos nos eselecimentos de saúde, conforme os Manuais Práticos propostos, e o Estado deve proporcionar condições de instalação e manutenção adequadas, além de fiscalizar e aplicar as penas cabíveis aos infratores, em detrimento da saúde pública. O olhar da arquitetura para a prevenção é ocaminho a ser seguido. A questão ambiental é fator fundamental, portanto, os três temas, ar condicionado, resíduos e esgoto e reúso de água estão relacionados ao meio ambiente,refletindo na saúde pública.
2

Reúso de efluentes industriais gerados durante a produção de água purificada na Central de Tratamento de Água do Centro Tecnológico de Vacinas de Bio-Manguinhos/FIOCRUZ / Reuse of waste water generated during production of purified water in the Water Treatment Center of the Technological Center of Bio- Manguinhos Vaccine / FIOCRUZ

Andrade, Bárbara de Azevedo Scangarelli de January 2014 (has links)
Made available in DSpace on 2015-08-19T13:52:54Z (GMT). No. of bitstreams: 2 16.pdf: 932960 bytes, checksum: b1d8e89ad8512d3f98cec245642f5d48 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto de Tecnologia em Fármacos/Farmanguinhos. Rio de Janeiro, RJ, Brasil. / Um dos maiores problemas ambientais é a preocupação mundial com a manutenção da qualidade da água para o uso humano. O seu uso intensivo nos setores agrícolas e industriais tem reduzido a sua disponibilidade para o uso doméstico. Uma das alternativas para a redução da extração de água e da poluição hídrica é a prática do reúso. Embora o Brasil não possua uma legislação específica que incentive essa prática, algumas indústrias já possuem em sua política interna o reúso e/ou recuperação de água para a redução de seus custos de fornecimento e de descarte de águas residuárias. Este trabalho estudou a viabilidade de reúso direto das águas residuárias industriais provenientes do processo de produção de água purificada por osmose reversa do Centro Tecnológico de Vacinas (CTV) de Bio-Manguinhos/FIOCRUZ. Foi realizado um levantamento do consumo, da qualidade e do custo da água que abastece os diferentes setores do CTV bem como a qualidade e a quantidade dos rejeitos do sistema de osmose reversa (P1), do analisador de COT (P2) e do gerador de ozônio (P3). Embora esse assunto seja importante no âmbito ambiental, econômico e social, poucos artigos científicos foram encontrados nos principais bancos de dados consultados, principalmente nos termos de reúso direto no setor industrial farmacêutico. A produção de água purificada é a atividade que demanda maior quantidade de água seguida pelas torres de resfriamento e pela produção de vapor industrial. A qualidade dos rejeitos da osmose reversa foi superior a água que abastece os sistemas de refrigeração, além disso, o volume descartado equivale ao necessário para atender às necessidades desses sistemas.A redução no consumo estimado com a aplicação deste projeto poderá ser de até17% de toda água consumida pelo CTV correspondendo a uma economia bruta direta em torno de R$ 500.000,00 por ano. / The great environmental problem is a worldwide preoccupation with maintaining the water quality for human use. Its intensive use in the agricultural and industrial sectors has reduced its availability for domestic use. An alternative to reduce of water extraction and pollution is the reuse practice. Although Brazil has no specific legislation that encourages this practice, some industries already have in their internal politics for water reuse and/or recovery t o reduce their costs of supply and disposal of wastewater. This work studied the feasibility of direct reuse of industries wastewater from the water purified production process by reverse osmosis of the Technological Centre Vaccines (TCV) in Bio-Manguinhos/FIOCRUZ. A survey of consumption, quality and cost of water supplied to different sectors of the CTV and the quality and quantity of the wastewater of Reverse Osmosis System (P1), the TOC analyzer (P2) and the ozone generator (P3). Although this issue is important in environmental, economic and social context, few articles were found in the main banks of data consulted, especially in terms of direct reuse in the pharmaceutical industry. The production of purified water is the activity that demands more water followed by cooling towers and the production of industrial steam. The quality of the wastewater from the reverse osmosis was superior to that water that supplies cooling systems, furthermore, the volume discarded equal to that necessary to meet the needs of these systems. The reduction in the estima ted consumption with the application of this project may be up to 17% of all water consumed by CTV corresponding to a direct gross savings of around R$ 500,000.00 per year.

Page generated in 0.0889 seconds