• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desempenho e dispêndio metabólico-ventilatório nos testes clínicos funcionais e a influência de um programa de treinamento físico aeróbio em pacientes com doença pulmonar obstrutiva crônica

Marrara, Kamilla Tays 02 December 2011 (has links)
Made available in DSpace on 2016-06-02T20:18:16Z (GMT). No. of bitstreams: 1 4019.pdf: 2106068 bytes, checksum: 932a130726834c5d08398e67e560bd4d (MD5) Previous issue date: 2011-12-02 / Universidade Federal de Sao Carlos / Objectives: To compare the metabolic demand ( O2/ O2peak), ventilatory demand ( E/MVV), dyspnea, fatigue on lower limbs (LL), oxygen peripheral saturation (SpO2) and functional capacity (number of climbs in step and work efficiency) at the peak of the six minutes step test (ST6) among patients with chronic obstructive pulmonary disease (COPD) stages II and III; Verify that there is relation of number of climbs in step with the first second forced expiratory volume (FEV1), BODE index, SpO2 and oxygen consumption ( O2) peak obtained in TD6, as well as with the distance walked in the six minutes walk test (6MWT) and in incremental symptom-limited cardiopulmonary test (CPT). Methods: Were evaluated 19 patients with stage II of COPD (50%  forced expiratory volume in one second (FEV1) 80%), composing the Group 1 (G1) and 16 with stage III of COPD (30%  FEV1  50%), constituting the Group 2 (G2) through ST6, 6MWT and CPT. Results: Were observed values significantly greater than dyspnea obtained at the peak of ST6 for G2, as well as significantly lower values of SpO2 at the peak of this test to the same group, as well as the number of climbs in step and distance walked in 6MWT and CPT. The number of climbs in step showed positive correlation with the SpO2 for G2, with r = 0.85. Conclusion: The patients with COPD stage III provided greater perception of dyspnea and desaturation in the ST6. In addition the same demonstrated reduced functional capacity when compared to patients with COPD stage II. And with relationship of number of climbs in ST6 with several variables, noted strong correlation with the SpO2 for patients with COPD stage III. / Objetivos: Comparar a demanda metabólica ( O2/ O2pico), demanda ventilatória ( E/VVM), dispnéia, fadiga nos membros inferiores (MMII), saturação periférica de oxigênio (SpO2) e capacidade funcional (número de subidas no degrau e eficiência de trabalho) no pico do teste do degrau de seis minutos (TD6) entre os pacientes com doença pulmonar obstrutiva crônica (DPOC) estádios II e III; verificar se há relação do número de subidas no degrau com o índice BODE, volume expiratório forçado no primeiro segundo (VEF1), SpO2 e consumo de oxigênio ( O2) pico obtidos no TD6, bem como com a distância percorrida no teste de caminhada de seis minutos (TC6) e no teste cardiopulmonar incremental limitado por sintomas (TCP). Métodos: Foram avaliados 19 pacientes com DPOC estádio II, compondo o Grupo II (G1) e 16 com DPOC estádio III, constituindo o Grupo III (G2) por meio do TD6, TC6 e TCP. Resultados: Observou-se valores significativamente maiores de dispnéia obtida no pico do TD6 para o G2, assim como valores significativamente menores de SpO2 no pico deste teste para o mesmo grupo, bem como do número de subidas no degrau e da distância percorrida no TC6 e no TCP. O número de subidas no degrau mostrou correlação positiva com a SpO2 para o G2, com r= 0,85. Conclusão: Os pacientes com DPOC estádio III apresentaram maior percepção de dispnéia e dessaturação ao executarem o TD6. Cabe também ressaltar que os mesmos demonstraram reduzida capacidade funcional quando comparados aos pacientes com DPOC estádio II. E quanto à relação do número de subidas no TD6 com diversas variáveis, observou-se correlação forte com a SpO2 para os pacientes com DPOC estádio III.
2

Efeitos da ventilação mecânica não-invasiva na variabilidade da freqüência cardíaca e no padrão ventilatório de pacientes submetidos à cirurgia de revascularização do miocárdio

Pantoni, Camila Bianca Falasco 26 June 2009 (has links)
Made available in DSpace on 2016-06-02T20:19:11Z (GMT). No. of bitstreams: 1 2553.pdf: 1596497 bytes, checksum: 1c1b091ddb6a8fb9d0cc5e1b5bfd8201 (MD5) Previous issue date: 2009-06-26 / Universidade Federal de Minas Gerais / Noninvasive positive pressure ventilation (NIPPV) has been commonly applied in several clinical and postoperative conditions, especially after coronary artery bypass grafting (CABG) surgery and it can cause breathing pattern (BP) alterations and mechanical effects on cardiovascular system, with cardiac autonomic adjustments. However, it is not well established in the literature how these alterations occur in patients submitted to the CABG and if they can be related to the application of different positive airway pressure levels. In this context, we considered the development of two studies that could contribute with new information about these topics. The first study is entitled Acute application of bilevel positive airway pressure influence cardiac autonomic nervous system and its objective was to evaluate the changes in heart rate variability (HRV) during bilevel positive airway pressure (Bilevel) application in healthy young men. Twenty men underwent a 10-min register of R-R intervals (R-Ri) during sham ventilation, Bilevel 8-15cmH2O and Bilevel 13-20 cmH2O. HRV was analyzed in time and frequency-domain and with non-linear statistical measures. Physiological variables (blood pressure, breathing rate, end tidal carbon dioxide- ETCO2) were also collected. R-Ri mean, rMSSD, NN50, pNN50 and SD1 reduced during 13-20 cmH2O compared to sham ventilation, with reduction of the R-Ri mean compared to 8-15 cmH2O. R-Ri mean and high frequency band (HF) reduced and low frequency band (LF) increased during 8-15 cmH2O compared to sham ventilation. Delta of ETCO2 correlated positively with LF, HF, LF/HF, SDNN, rMSSD and SD1. In conclusion, acute application of Bilevel was able to alter cardiac autonomic nervous system, with parasympathetic activity reduction and sympathetic increase and higher level of positive airway pressure can cause a greater influence on the cardiovascular and respiratory system. The second study is entitled The effects of different levels of positive airway pressure on respiratory pattern and heart rate variability in patients submitted to coronary artery bypass grafting surgery and its objective was to access the effects of different levels of continuous positive airway pressure (CPAP) in BP and HRV in CABG postoperative (PO), as well as the impact of CABG in these variables. Eighteen patients underwent CABG was evaluated during spontaneous breathing (SB) and four different CPAP levels of CPAP, in a random order: (a) CPAP = sham (3 cmH2O), (b) 5 CPAP = cmH2O, (c) 8 CPAP= cmH2O, (d) 12 CPAP = cmH2O in PO. HRV was analysed in time and frequency domain and by non-linear methods (Poincaré plot e Detrended Fluctuation Analysis) and BP was analysed by inductive respiratory plethysmograph. There were significant alterations of HRV and BP in the PO of CRM, compared to pre-operative and alterations of DFAα1, DFAα2 e SD2 and respiratory variables during NIPPV, with higher influence observed during application of the two higher levels applied. Moreover, there was relationship between DFAα1 and inspiratory time of delta 12 cmH2O and SB, and 8 cmH2O and SB. In conclusion, acute CPAP application was able to alter the control of cardiac autonomic nervous system and BP of patients submitted to CABG and higher levels promoted better performance of pulmonary and cardiac autonomic function. / A ventilação não-invasiva por pressão positiva (VNIPP) tem sido comumente utilizada em diversas condições clínicas e pós-operatórias, principalmente na cirurgia de revascularização do miocárdio (CRM) e pode causar alterações do padrão ventilatório (PV) e efeitos mecânicos sobre o sistema cardiovascular, com ajustes autonômicos cardíacos. Entretanto, ainda não é claro se estas alterações ocorrem em pacientes submetidos à CRM e se podem estar relacionadas a diferentes níveis pressóricos aplicados. Neste contexto, propusemos o desenvolvimento de dois estudos que poderiam contribuir com novas informações. O primeiro estudo, intitulado Aplicação aguda de pressão positiva por dois níveis pressóricos nas vias aéreas influencia o sistema nervoso autonômico cardíaco teve por objetivo avaliar as mudanças na variabilidade da frequência cardíaca (VFC) durante aplicação de pressão positiva por dois níveis pressóricos (Bilevel) em indivíduos jovens saudáveis. Vinte homens foram submetidos ao registro de 10 minutos dos intervalos R-R (iR-R) durante aplicação de ventilação sham, Bilevel 8- 15cmH2O e Bilevel 13-20 cmH2O. A VFC foi analisada no domínio do tempo e da freqüência e por métodos não-lineares. Variáveis fisiológicas (pressão arterial, frequência respiratória e fração de dióxido de carbono no final da expiração- ETCO2) também foram coletadas. Houve redução da média dos iR-R, e dos índices rMSSD, NN50, pNN50 e SD1 durante aplicação dos níveis 13-20 cmH2O de Bilevel comparado ao modo sham, ainda com redução da média dos iR-R quando comparados aos níveis 8-15cmH2O. Houve diminuição da média dos iR-R e da banda de alta freqüência (AF), com aumento da banda de baixa freqüência (BF) durante a aplicação de 8-15 cmH2O comparada à ventilação sham. O delta de ETCO2 correlacionou-se positivamente com BF, AF, BF/AF, SDNN, rMSSD e SD1. Em conclusão, a aplicação aguda de Bilevel foi capaz de alterar o sistema nervoso autonômico cardíaco, com redução da atividade parassimpática e aumento da atividade simpática e níveis mais elevados de pressão positiva podem causar maior influência nos sistemas cardiovascular e respiratório. O segundo estudo, intitulado Efeitos de diferentes níveis de pressão positiva nas vias aéreas sobre o padrão ventilatório e a variabilidade da freqüência cardíaca de pacientes submetidos à cirurgia de revascularização do miocárdio objetivou avaliar os efeitos da aplicação de diferentes níveis de pressão positiva contínua nas vias aéreas (CPAP) sobre o padrão ventilatório (PV) e a VFC no pós-operatório (PO) de CRM, bem como o impacto da CRM sobre estas variáveis. Foram avaliados 18 pacientes submetidos à CRM, durante RE (respiração espontânea) e aplicação de quatro níveis de CPAP, de forma randomizada: (a) CPAP = sham (3 cmH2O), (b) CPAP = 5 cmH2O, (c) CPAP= 8 cmH2O, (d) CPAP = 12 cmH2O no PO. A VFC foi analisada no domínio do tempo e da freqüência e por métodos não-lineares (Poincaré plot e Flutuações Depuradas de Tendência) e o PV foi analisado em diferentes variáveis, por meio da pletismografia respiratória por indutância. Houve alteração da VFC e do PV no PO de CRM, comparado ao período pré-operatório, bem como alterações dos índices DFAα1, DFAα2 e SD2, e de variáveis ventilatórias durante aplicação de VNIPP, com maior influência exercida pela aplicação dos dois níveis pressóricos mais elevados. Além disso, houve correlação entre o índice DFAα1 e tempo inspiratório para o delta de 12 cmH2O e RE, e 8 cmH2O e RE. Em conclusão, temos que a aplicação aguda de CPAP foi capaz de alterar o controle do sistema nervoso autonômico cardíaco e o PV de pacientes submetidos à CRM e os níveis mais elevados promoveram melhor desempenho da função pulmonar e autonômica cardíaca. Apoio Financeiro: FAPESP (07/53202-9).

Page generated in 0.0918 seconds