• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 24
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 68
  • 25
  • 25
  • 21
  • 18
  • 13
  • 10
  • 9
  • 9
  • 8
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

CAD-CAM ceramic veneers : tooth preparation status, accuracy of Intra Oral Scanner and mechanical behavior / Facettes céramiques et CFAO : évaluation des états de surface des préparations : précision de l’empreinte optique intra-orale : comportement mécanique de la restauration

Yusuf Solieman, Osama 26 November 2018 (has links)
Au cours des vingt dernières années, les facettes céramiques sont devenues une solution esthétique très répandue en raison de leur conception de préparation peu invasive, de leurs propriétés biocompatibles, de leur similitude avec la couleur naturelle des dents, ainsi que de leur translucidité et de leur résistance mécanique aux forces occlusales et à l’usure [1]. La définition des facettes dentaires est celle de « coquilles » très minces, faites sur mesure de matériaux de la couleur de la dent, conçues pour recouvrir la face avant ou la face supérieure des dents afin d' en améliorer l'esthétique et/ou corriger des problèmes occlusaux. Elles sont collées aux dents et pourront en modifier la couleur la forme, et le volume [2].Elles trouvent ainsi de multiples indications à différents endroits sur les arcades dentaires sur les faces vestibulaires des dents antérieures ou plus récemment pour restaurer les surfaces occlusales corriger une occlusion déficiente [3, 4].Ces restaurations modernes se sont développées avec l'arrivée de nouveaux matériaux de reconstructions et de collages, ainsi que de nouveaux modes de conception et fabrication répondant à des exigences de simplicité, de rapidité et de précision.Pour préparer la dent à recevoir une facette, l'oscillation d’inserts ultrasonores a été proposée pour améliorer la finition des lignes marginales et optimiser l’état de surface [5].Pour leur fabrication, outre les méthodes prothétiques classiques, la CFAO (conception assistée par ordinateur - fabrication assistée par ordinateur) au développement exponentiel [6, 7 permet de réaliser une prothèse restauratrice en une seule visite en clinique avec la précision que permettent l’optique (empreintes) et la robotique (fabrication de la facette) ;[8-14]. D’autre part l’apparition de nouvelles céramiques a permis d'améliorer leur esthétique et d'augmenter leur durabilité, qu'elle soit antérieure ou occlusale.Notre première étude portait sur de nouveaux outils permettant d'optimiser la procédure de préparation des facettes. L'utilisation ou non d‘inserts oscillants sur la qualité de l'état de surface de la dent traitées pour une telle préparation. Cette question importante et récurrente, [15] pose le problème de la qualité de l'état de surface destiné à recevoir par collage une pellicule de céramique de faible épaisseur. La pérennité de ce type de prothèse dépend essentiellement du collage avec les tissus dentinaires préparés [16, 17]. La littérature, atteste d’une meilleure qualité de collage entre des surfaces dentaires rugueuses et les matériaux de restauration [18-22]. Toutefois, une question se pose concernant la qualité de cette rugosité lorsque / The first chapter of the thesis relieved the dentists from thinking a lot about the produced roughness regardless to the preparation tool. The roughness is a critical factor to the stability, to the retention, and eventually to the success of the ceramic veneers especially for the esthetic anterior veneers. This will speed up the procedure of achieving a fast treatment for the patients with the CAD-CAM systems. For the upcoming steps, an investigation is recommended to estimate the amount of the inquired roughness to achieve the minimum necessary adhesion value for the retention of the ceramic veneers, and vice versa, another investigation to evaluate the capability of the preparation tools in transferring the same roughness from the preparation tool grains to the target surface (dentin or enamel).152The second study had filled the gap of how to evaluate the IOS systems regardless to the recent common criteria, and the thesis created a novel measure (noise) to be used. The study asks the dentists to pay attention to other criteria to consider when buying an IOS system regardless to the criteria that already exists and had been directed by the producing companies. The thesis states that the noise increases when the direction of the IOS is changed. More attention should be paid at the transitional lines between the scanned surfaces while designing the digital model. An enhancement is demanded to compensate for (or if possible, to eliminate) this noise.
42

Efeito de diferentes tratamentos de superfície na resistência de união, ângulo de contato, morfologia e análise da distribuição de tensão de laminados ultrafinos de cerâmica reforçada por dissilicato de lítio /

Escobar, Lorena Cristina Bogado. January 2017 (has links)
Orientador: Maria Filomena Rocha Lima Huhtala / Banca: Alexandre Luiz Souto Borges / Banca: Marcelo Giannini / Resumo: Laminados cerâmicos são utilizados em tratamentos conservadores para restabelecer estética e função com mínimo desgaste da estrutura dental. O objetivo deste estudo foi avaliar, in vitro, o efeito de dois tratamentos de superfície em espécimes cerâmicos ultrafinos de dissilicato de lítio na resistência de união com o cimento resinoso. Laminas ultrafinas de cerâmica (14 X 12 X 0,3 mm) foram distribuídas aleatoriamente em dois grupos (n=20) de acordo com o tratamento de superfície: ácido hidrofluorídrico 5% durante 20 s e silano (HF) e Monobond Etch & Prime (Ivoclar, Vivadent) por 60 s (MEP). Dois cilindros de cimento resinoso foram confeccionados utilizando matrizes cilíndricas. Após 24 h de armazenamento, os espécimes foram submetidos ao ensaio mecânico de microcisalhamento (1 mm/min) e o modo de falha foi estabelecido. Dados de resistência de união foram analisados pelo teste t de Student (α=0.05). O ângulo de contato foi determinado. Análise morfológica das superfícies cerâmicas por meio de microscopia de força atômica e eletrônica de varredura foi realizada. Através de análise por elementos finitos foi estudada a distribuição de tensão em incisivos centrais superiores restaurados com laminados cerâmicos ultrafinos de dissilicato de lítio (0,3 mm). O modelo tridimensional foi elaborado no software Rhinoceros e exportado para software de análise Ansys. Foram modelados e analisados 04 grupos sob duas condições: desgaste ou não de esmalte e tipo de preparo. Foi aplicada uma ca... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Laminate veneers are becoming a technique used in the conservative treatments by the ability to restore aesthetics and function. This study aimed to evaluate, in vitro, the effect of two surface treatments on ultrathin lithium disilicate specimens in bond strength between treated ceramics and resin cement. Ceramic ultrathin laminates (12 X 14 X 0.3 mm) were obtained and randomly distributed into two groups (n=20) according to the surface treatment: 5% hydrofluoric acid for 20 s and silane (HF) and Monobond Etch & Prime (Ivoclar, Vivadent) for 60 s (MEP). Two resin cement cylinders were made using cylindrical matrices. After 24 h storage, microshear bond strength tests were performed in a universal testing machine (1 mm/min) and failure mode was analyzed. Bond strength data were submitted to Student's t-test (α=0.05). The contact angle was measured. Micromorphogical analyses of representatives specimens were also performed (atomic force and scanning electron microscopy). Finite element analysis studied the distribution of stress in maxillary central incisors restored with ultrathin laminate veneers of lithium disilicate (0.3 mm). 3D model was elaborated in CAD Rhinoceros® software and exported to analysis software Ansys®. Four groups were modeled and analyzed under two experimental conditions: wear or non-enamel and type of preparation. A load of 100 N was applied at the palatal face. The stress was analyzed by Maximum Principal Stress criteria. Microshear bond strength values... (Complete abstract click electronic access below) / Mestre
43

Laminados cerâmicos em pré-molares : análise tridimensional pelo método dos elementos finitos /

Archangelo, Carlos Marcelo. January 2008 (has links)
Orientador: Eduardo Passos Rocha / Banca: Marco Antonio Luersen / Banca: Luciano Tavares Angelo Citra / Banca: Wirley Gonçalves Assunção / Banca: Rodrigo Nunes Rached / Resumo: Objetivo: O objetivo do presente estudo foi avaliar através do método dos elementos finitos tridimensional (3D FEA), o comportamento mecânico de uma faceta laminada de cerâmica e do cimento resionoso em um 1o pré-molar maxilar, variando a redução (parcial ou total) da cúspide vestibular. Material e método: Baseado em imagens micro-tomográficas (μCT) 2 modelos (M) tridimensionais foram construídos no programa Solidworks 2007 variando a redução da cúspide vestibular, sendo Mp o modelo composto pelo dente pré-molar restaurado com uma faceta laminada de cerâmica, com redução parcial da cúspide vestibular e Mt, o modelo semelhante ao Mp, porém com redução total da cúspide vestibular. O programa de elementos finitos ANSYS Workbench 10.0 foi utilizado para realizar as análises. O carregamento (150 N) foi aplicado próximo à ponta de cúspide vestibular, com 45º de inclinação. Foram utilizados os critérios da máxima tensão principal ( max) e da máxima tensão cisalhante ( shear) na faceta laminada e na camada de cimento resinoso. Resultados: O Mt mostrou menor shear em 9 das 12 áreas analisadas quando comparado ao Mp. O Mp mostrou menor variação da max (de -3,13 para 14,4 MPa) que o Mt para a lâmina de cerâmica (de -2,08 para 24,3 MPa) A camada de cimento apresentou variação de max semelhante entre os Mp e Mt. Os critérios de tensões utilizados não evidenciaram valores além dos limites estabelecidos para a falha estrutural do material estudado. Conclusão: O laminado cerâmico e a camada de cimento resinoso apresentaram comportamento mecânico favorável para a restauração do pré-molar frente ao carregamento adotado. O tipo de redução de cúspide não influenciou no aumento expressivo das tensões principal e cisalhante. O Mp apresentou menores valores de max em tração quando comparado ao Mt. O Mp e o Mt apresentaram comportamento favorável com relação as forças cisalhantes, sendo as maiores tensões. / Abstract: Objectives: Using 3-D finite element analysis (FEA) and μCT data, the aim of this study was to evaluate the behavior of the laminate veneer and the resin luting cement in a maxillary premolar with the buccal cusp partially or completed covered. Material and method: 2 3-D FEA models of a maxillary premolar were built from μCT data. All models were restored with a feldspathic laminate veneer using Solidworks. A similar tooth reduction (0.5mm) was applied for two models. The buccal cusp reduction of the premolar followed two configurations: Model (Mt) - buccal cusp completely covered by veneer; and Model (Mp) - buccal cusp partially covered by veneer. The loading (150N, in 45o) was performed on the buccal cusp of each premolar. Appropriate boundary condition was applied at the periodontal ligament surfaces and ANSYS (10.0) was used to obtain the maximum shear stress ( shear) and maximum principal stress ( max) for the laminate veneer and resin luting cement layer. Results: The Mp showed higher shear than Mt in 9 to 12 analyzed areas. The Mp showed smallest variation of max in laminate veneer (from -3,13 to 14,4 MPa) compared with Mt (from - 2,08 to 24,3 MPa). The resin luting cement showed similar variation of max between Mp and Mt (from -3.13 to 12.2 MPa) and (from -1.61 to 14.1 MPa), respectively. None of the structures exceeded the ultimate tensile strength or the shear bond strength to dentin and enamel. Conclusion: The laminate veneer and the resin luting cement layer showed an adequate behavior when veneer was applied in premolars. Cusp reduction did not affect significant increase in max and shear. In general, the Mp showed better behavior ( max) than Mt. The Mt showed better behavior ( shear) than Mp. / Doutor
44

Laminados cerâmicos cimentados sobre dentes não preparados. Estudo clínico, prospectivo e longitudinal sobre a adaptação marginal e avaliação do comportamento periodontal pelo uso de biomarcadores do fluido gengival crevicular /

Souza, Fernando Isquierdo de. January 2018 (has links)
Orientador: Eduardo Passos Rocha / Coorientadora: Sandra Helena Penha de Oliveira / Banca: Roberta Okamoto / Banca: Andre Luiz Fraga Briso / Banca: Estevam Augusto Bonfante / Banca: Carlos Ferreira dos Santos / Resumo: Objetivo: Quantificar os biomarcadores e o volume do fluido gengival crevicular (GCF), com adicional verificação da adaptação e comportamento marginal de laminados cerâmicos delgados cimentados sobre dentes sem término cervical e apresentando borda marginal posicionada no interior do sulco gengival. Materiais e Métodos: 73 dentes maxilares foram tratados com laminados cerâmicos em dissilicato de lítio monolítico. Para todos os elementos foi feita a coleta do GCF previamente à cimentação (baseline) e nos tempos do estudo (t0- 7 dias, t4 180 dias), onde foi calculado o volume do GCF e quantificado os biomarcadores: TNF-α, IL-1β, MMP-8 por ELISA. O dente vizinho ou antagonista foi utilizado como controle. Foram obtidas réplicas da região cervical em resina epóxi, em t0 e t4 para verificação da adaptação marginal em microscópio eletrônico de varredura. A avaliação clínica foi realizada pelos critérios modificados do USPHS nos tempos do estudo e com 1 ano de acompanhamento (t5). Resultados: Os níveis de TNF-α e MMP-8 se mantiveram estáveis na comparação de t4 com o baseline (p>0,05). A concentração de IL-1β aumentou em t4 no grupo tratado em comparação com o baseline (p<0,05), porém sem diferença estatística significante para o grupo controle em t4 e no baseline (p>0,05). Todos os elementos obtiveram conceito alfa para avaliação clínica e microscópica. Conclusão: No período de acompanhamento proposto pelo presente estudo, o periodonto de proteção apresentou excelente comportamento... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: To quantify the biomarkers and gingival crevicular fluid (GCF) volume, with additional verification of the adaptation and marginal behavior of thin ceramic veneers cemented on teeth without cervical preparation, with the finish line gently positioned within the gingival sulcus. Materials and Met hods: 73 maxillary teeth were treated with monolithic lithium disilicate ceramic veneers . For all elements, the GCF was collected before cementation ( baseline) and at the study times (t0 -7 days, t4 180 days), which was calculated the GCF volume and the quantification of the biomarkers: TNF - α, IL - 1β, MMP -8 by ELISA. The neighboring or antagonist tooth was used as a control. Replicas of the cervical region were obtained in epoxy resin, in t0 and t4 to verify the marginal adaptation in a scanning electron mi croscope. Clinical e valuation was performed using the modified USPHS criteria at study times and at 1 year of follow -up (t5). Results: TNF - α and MMP -8 levels remained stable in the comparison of t4 with the baseline (p> 0.05). The concentration of IL- 1β in creased in t4 in the treated group compared to the baseline (p <0.05), but without significant statistical difference for the control group in t4 and baseline (p> 0.05). All the elements obtained alpha concept for clinical and microscopic evaluation. Concl usion: In the period of follow -up proposed by the present study, the protection periodont ium presented excellent clinical and biological behavior in re... (Complete abstract click electronic access below) / Doutor
45

Avaliação da distribuição de tensões nas facetas estéticas de porcelana pelo método de elementos finitos

Pereira, João Luiz Neves 08 December 2005 (has links)
Made available in DSpace on 2017-07-24T19:22:12Z (GMT). No. of bitstreams: 1 Joao Luiz Neves.pdf: 1812596 bytes, checksum: a76cbc76ce0b003aad7f933da512d1bd (MD5) Previous issue date: 2005-12-08 / The present work had the objective to evaluate the distribution of tensions in teeth restored with aesthetic porcelain laminates by the finites elements method, in representative models of upper incisors central, where three types of simulation had been used: teeth that did not present dental preparations with and without covering of the incisal edge, and teeth that had preparation in shoulder form and layering of the incisal edge. These models had been submitted to the loads of 100N and 350 N in the incisal edge, under angles of 450 and 900, simulating clinical conditions of carrying patients of class I of the Angle and patients with direct bite of the incisors and/or bruxomanos. We observed that the increase of the load, as well as the reduction of the angulations, had promoted an increase to the tensions in the representative models of porcelain laminate, and that the models represented by the lithium dissilicato porcelain, presented a better behavior in relation to the distribution of the tensions on teeth restored with feldspática porcelain laminate. / O presente trabalho teve por objetivo avaliar a distribuição de tensões nos dentes restaurados com facetas estéticas de porcelana pelo método de elementos finitos, em modelos representativos de incisivos centrais superiores onde foram utilizadas três tipos de simulações: dentes que não apresentavam preparos dentários com e sem recobrimento da borda incisal, e dentes com preparo em forma de ombro e com recobrimento da borda incisal. Estes modelos foram submetidos a cargas de 100N e 350 N na borda incisal, sob angulações de 450 e 900, simulando condições clínicas de pacientes portadores de classe I de Angle e pacientes com mordida de topo e/ou bruxomanos. Foi observado que o aumento de carga, bem como a diminuição da angulação, promoveu um aumento das tensões nos modelos representativos das facetas de porcelana, e que os modelos representados pela porcelana à base de dissilicato de lítio, apresentou um comportamento melhor em relação à distribuição das tensões sobre os dentes restaurados com facetas de porcelana feldspática.
46

Essential oil treatment of VTC wood

Scouse, Adam A. 13 September 2012 (has links)
Western juniper and cinnamon essential oils were combined with ethanol at 2.5, 5, and 10% concentrations by weight and applied to hybrid poplar (Populus trichocarpa x P. deltoids) veneers by vacuum soaking to produce a naturally durable wood veneer with increased mechanical properties for use in structural composites. Half of these veneers were then modified using viscoelastic thermal compression to increase veneer density and modulus of elasticity. Following densification, unprocessed and VTC processed veneers receiving an essential oil treatment were subjected to an AWPA E21-06 Formosan termite exposure test, AWPA E24-06 mold box test, and brown rot (Gloeophyllum trabeum) decay bending test. While VTC processing drastically reduced the abundance of chemical components inherent within essential oil treatments, veneer specimens without VTC processing showed increased durability. A 10% juniper oil treatment drastically reduced Formosan termite attack on hybrid poplar veneers while a 10% cinnamon oil treatment significantly reduced mold growth. Timbor��, an industrial powdered borate treatment, withstood VTC processing and inhibited Formosan termite attack and mold growth. Tests to evaluate the effectiveness of essential oil treatments against brown rot were unsuccessful. Results suggest that incorporating a disodium octaborate tetrahydrate (DOT) treatment prior to VTC processing could help improve VTC wood durability. / Graduation date: 2013
47

A comparative clinical evaluation of glaze materials with conventional finishing for composite resin restorations a thesis submitted in partial fulfillment ... in restorative dentistry, operative ... /

Brandau, Henry E. January 1978 (has links)
Thesis (M.S.)--University of Michigan, 1978.
48

A comparative clinical evaluation of glaze materials with conventional finishing for composite resin restorations a thesis submitted in partial fulfillment ... in restorative dentistry, operative ... /

Brandau, Henry E. January 1978 (has links)
Thesis (M.S.)--University of Michigan, 1978.
49

Avaliação da estabilidade de cor, grau de conversão e resistência à união de sistemas de cimentação submetidos ou não ao envelhecimento acelerado = Evaluation of color stability, degree of conversion and shear bond strength of luting systems according to accelerated aging / Evaluation of color stability, degree of conversion and shear bond strength of luting systems according to accelerated aging

Prieto, Lúcia Trazzi, 1984- 25 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-25T22:01:08Z (GMT). No. of bitstreams: 1 Prieto_LuciaTrazzi_D.pdf: 2940883 bytes, checksum: c9367f60f0af737b2b46e381a5ba5b3d (MD5) Previous issue date: 2014 / Resumo: O objetivo deste estudo "in vitro" foi avaliar as propriedades físicas e químicas de cimentos resinosos e resinas compostas de baixa viscosidade usados na cimentação de facetas laminadas, através da estabilidade de cor e resistência à união após envelhecimento e grau de conversão. Para isso foram utilizados 96 incisivos humanos extraídos divididos, aleatoriamente, em 6 grupos experimentais (n=8), formados pelos sistemas de fixação RelyX Veneer/ Single Bond 2 (3M ESPE), RelyX ARC/Single Bond 2 (3M ESPE), Filtek Z350 XT Flowable/Single Bond 2 (3M ESPE), Variolink Veneer/Tetric N-Bond (Ivoclar-Vivadent), Variolink II/ Tetric N-Bond (Ivoclar-Vivadent) e Tetric N-Flow/ Tetric N-Bond (Ivoclar-Vivadent), utilizados na cor A1. Para se avaliar a estabilidade de cor foram realizados desgastes com máquina de preparo na face vestibular de 0,6 mm de profundidade simulando preparos para facetas laminadas em 48 incisivos humanos e foram confeccionadas facetas laminadas em cerâmica IPS Empress Esthetic que foram cimentadas de acordo com os grupos experimentais. Vinte e quatro horas após a cimentação a cor inicial foi avaliada com o auxílio de espectrofotômetro (Easyshade-Vita). Após o envelhecimento acelerado por luz UV-B durante 300 horas (150Kj/m), nova mensuração de cor foi realizada. A avaliação da resistência ao microcisalhamento foi realizada selecionando outros 48 incisivos humanos (n=8) que receberam a cimentação de dois cilindros cerâmicos (IPS Empress Esthetic) (1 x 2 mm) sobre a face vestibular planificada, após vinte e quatro horas o primeiro cilindro foi acoplado à maquina EZ-test para o teste de resistência e o cilindro remanescente foi submetido ao envelhecimento acelerado por luz, e novo ensaio de resistência à união realizado, avaliando-se também o padrão de fratura em microscópio óptico. Para avaliação do grau de conversão foram confeccionados 60 espécimes (n=10) de cada material resinoso (5 x 0,5 mm) e os espectros de absorção foram obtidos através do espectrômetro Spectrum 100 FTIR/UATR. Os dados foram submetidos a Análise de Variância e teste de Tukey ('alfa'=0,05). Em relação a estabilidade de cor todos os materiais testados apresentaram grande alteração de cor perceptível clinicamente ('delta'E>3.3), porém não apresentaram diferença estatísticas entre si. Para a resistência à união os sistemas de fixação Single Bond 2/RelyX ARC e Tetric N-Bond/Variolink II apresentaram os melhores valores quando comparados aos demais sistemas, Tetric N-Bond/Variolink Veneer e Single Bond 2/ RelyX Veneer foram semelhantes entre si e superiores as resinas compostas de baixa viscosidade, que apresentaram os valores mais baixos. Em relação ao padrão de fratura os cimentos duais apresentaram maior porcentagem de fraturas do tipo coesiva em cerâmica (62,5%) enquanto os cimentos fotoativados e resinas de baixa viscosidade obtiveram maior porcentagem de falhas do tipo adesiva (50 a 75%). Quanto ao grau de conversão, RelyX ARC apresentou o melhor resultado, sendo que Variolink II, RelyX Veneer e Filtek Flow apresentaram resultados intermediários com diferenças estatísticas entre si e Tetric Flow e Variolink Veneer apresentaram o menor grau de conversão. Baseando-se nos resultados pôde-se concluir que os sistemas de fixação mostraram grande alteração de cor após o envelhecimento, em relação ao teste de microcisalhamento e grau de conversão os materiais duais obtiveram melhor desempenho quando comparados aos outros materiais testados. / Abstract: The aim of this " in vitro " study was to evaluate the chemical and physical properties of different resin cements and flowable resin composites used to lute veneers on enamel by color stability and bond strength submitted to accelerated artificial aging, and degree of conversion. Ninety-six extracted human incisors were randomly divided into 6 experimental groups (n = 8), according to the different luting systems evaluated: RelyX Veneer / Single Bond 2 (3M ESPE), RelyX ARC / Single Bond 2 (3M ESPE), Filtek Z350 XT Flowable/ Single Bond 2 (3M ESPE), Variolink Veneer / Tetric N - Bond (Ivoclar Vivadent), Variolink II / Tetric N - Bond (Ivoclar Vivadent) and Tetric N -Flow / Tetric N - Bond (Ivoclar Vivadent), used shade A1. To evaluate the color stability, wears of 0.6 mm thick were performed on labial surface to simulate veneer preparations. Forty-eight IPS Empress Esthetic veneers were cemented according to the experimental groups evaluated. Twenty-four hours after luting procedures the initial color was measured with spectrophotometry (Easyshade-Vita). After accelerated aging by UV-B light for 300 hours (150Kj/min), final color readout was measured. To evaluate the microshear bond strength another 48 human incisors was selected. Two ceramic cylinders (IPS Empress Esthetic) (d=1 mm x 2 mm thick) were lute on the labial enamel surface previous prepared as described before. After twenty-four hours, the first cylinder was coupled to the EZ -test machine for measuring the initial bond strength and, the remaining cylinder was submitted to accelerated artificial aging by light, and before bond strength test. Fracture pattern was analyzed under light microscope. To evaluate the degree of conversion 60 specimens (n=10) of each resin material (5x0.5 mm) were obtained and Fourier transform infrared spectroscopy (FTIR) was used to evaluate the absorption spectra. The data were submitted to ANOVA and Tukey test ('alfa'= 0.05). There was clinically perceptible color change ('delta'E > 3.3) for all materials tested; there were no statistical difference among the color stability of any luting materials. For bond strength test the luting systems single Bond2/ RelyX ARC and Tetric N-Bond/Variolink II showed the highest values when compared to others systems, Tetric N-Bond/Variolink Veneer and Single Bond 2/RelyX Veneer were similar between and superior to flowable resin composites, which showed lowest values. Regarding fracture pattern the dual cured resin cements showed a higher percentage of cohesive fracture patterns on ceramic (62.5%) and the light-cured resin cement and the flowable resin composites, adhesive fracture pattern (50-75%). For the degree of conversion, the following decreasing sequence was found: RelyX ARC>Variolink II>RelyX Veneer>Filtek Z350 XT Flowable>Tetric Flow>Variolink Veneer. For the microshear bond strength Single Bond 2/RelyX ARC=Tetric N-Bond/Variolink II =Tetric N-Bond/Variolink Veneer+Single Bond2/RelyX Veneer >flowable resin composite. Based on the results it was concluded that the luting systems showed great after artificial aging, in relation to microshear bond strength test and the degree of conversion of the dual-cured resin cements obtained better performance compared to light-cured resin materials tested / Doutorado / Dentística / Doutora em Clínica Odontológica
50

Influência do tipo de preparo na adaptação interna e infiltração marginal em laminados cerâmicos /

Pierre, Fernanda Zapater. January 2019 (has links)
Orientador: João Mauricio Ferraz da Silva / Banca: Virgílio Vilas Boas Fernandes Jr. / Banca: Rodrigo Máximo de Araújo / Resumo: Este estudo laboratorial teve como objetivo avaliar a infiltração marginal, adaptação interna e gap cervical de laminados cerâmicos, em função da realização ou não de preparo. Método: Vinte e quatro incisivos centrais superiores hígidos, com volumes e tamanhos padronizados, foram subdivididos em dois grupos, n=12, de acordo com o tipo de preparo. GRUPO CP - minimamente invasivo com linha de término na extensão do preparo; GRUPO SP - sem preparo, somente remoção de áreas retentivas. Todos os espécimes foram moldados com silicone de adição (Virtual Ivoclar - Vivadent), e sobre os modelos obtidos foram confeccionados laminados em cerâmica de Dissilicato de Lítio (Emax Press Ivoclar-Vivadent) com espessuras entre 0.3/0.7mm. Após ajustes, as peças foram cimentadas com cimento resinoso fotopolimerizável (Variolink Esthetic LC Ivoclar - Vivadent), seguindo as recomendações do fabricante. Em seguidas os espécimes foram envelhecidos em cicladoras térmica, 6.000 ciclos de 5 a 55ºC, e mecânica com 100N por 100.000 ciclos. Após o término das ciclagens todos foram imersos em substância corante por 24 horas e cortados paralelamente ao eixo do dente e horizontalmente para avaliação da infiltração marginal, adaptação interna e gap cervical em esteriomicroscópio. Os resultados apontaram que, na infiltração marginal, o grupo CP teve a maior média na região cervical (1,601 mm) comparado ao grupo SP (1,471 mm), porém não estatisticamente significante. Em ambos os grupos a infiltração marginal na... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract : This laboratory study aimed to evaluate the marginal infiltration, internal adaptation and cervical gap of ceramic laminate venners, by whether or not preparation. Method: Twenty-four upper central incisors with standard volumes and sizes were subdivided into two groups, n = 12, according to the type of preparation. CP GROUP - minimally invasive with finishing line in preparation extension; GRUPO SP - without preparation, only removal of retentive areas. All the specimens were molded with addition silicone (Virtual Ivoclar - Vivadent), on the obtained models laminates in ceramic of Lithium Dissilicate (Emax Press Ivoclar - Vivadent) were made with thicknesses between 0.3 / 0.7mm. After adjustments, the pieces were cemented with photopolymerizable resin cement (Variolink Esthetic LC Ivoclar - Vivadent), following the manufacturer's instructions. Then the specimens were aged in thermal cycling machine, 6,000 cycles of 5 to 55ºC, and mechanical with 100N per 100,000 cycles. After the cycling, all specimens were immersed in dye substance for 24 hours and cut parallel to the axis of the tooth and horizontally for evaluation of marginal infiltration, internal adaptation and cervical gap in stereomicroscope. The results showed that, in marginal infiltration, the CP group had the highest mean in the cervical region (1.601 mm) compared to the SP group (1.471 mm), but not statistically significant. In both groups the marginal infiltration in the cervical region was greater than in the proximal one, differing statistically. Internal adaptation was better in the CP group in the three thirds analyzed, but only in the cervical third there was a statistically significant difference. The cervical gap had lower values in the SP group, but without statistically significant difference. It was concluded that the type of preparation did not have significant influence in terms of marginal.. (Complete abstract click electronic access below) / Mestre

Page generated in 0.0446 seconds