• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • 2
  • Tagged with
  • 73
  • 73
  • 60
  • 33
  • 29
  • 27
  • 24
  • 20
  • 19
  • 17
  • 16
  • 16
  • 15
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Estudo da ventilação natural por efeito do vento em pavilhões industriais utilizando modelos reduzidos / The use of reduced models in the study of wind induced natural ventilation in industrial buildings

Nunes, Daniel Alexandre January 2006 (has links)
A ventilação natural pode ser promovida por dois mecanismos: o denominado efeito chaminé e o efeito dos ventos, porém também podem ocorrer os dois mecanismos simultaneamente. A determinação das vazões de ventilação por efeito do vento, em pavilhões industriais, pode ser realizada a partir de ensaios de modelos reduzidos em túnel de vento, com medição das velocidades do escoamento nas aberturas, ou então, com medição dos coeficientes de pressão em modelos fechados, nas faces onde estão localizadas as aberturas. A metodologia com medição dos coeficientes de pressão, que exige o emprego de um modelo teórico para calcular as vazões, é a forma convencional de usar o túnel de vento como ferramenta no projeto de ventilação. O objetivo deste trabalho é avaliar os procedimentos citados, para calcular as vazões de ventilação por efeito do vento em pavilhões industriais. Para atingir esse objetivo foram ensaiados em túnel de vento dois modelos reduzidos (escala geométrica 1:200) de um pavilhão industrial: um sem aberturas, para a medição dos coeficientes de pressão, e outro, com aberturas de ventilação de área variável, para a medição das velocidades do vento com anemômetro de fio quente. Além da comparação das duas metodologias para determinação das vazões de ventilação, os resultados dos ensaios foram também utilizados para analisar as alterações nas vazões de ventilação e nas velocidades do escoamento do ar decorrentes do fechamento de algumas aberturas do modelo estudado. Conclui-se que as aberturas localizadas na cumeeira e o tipo de escoamento exercem grande influência nas vazões de ventilação. A utilização da metodologia de medição direta de velocidades através de anemômetro de fio quente permite a obtenção de vazões de ventilação sem iterações, com resultados compatíveis com os modelos teóricos que se baseiam na diferença de pressões externas e internas. / Natural ventilation in industrial buildings may be promoted by two mechanisms: one due to wind effects and other called chimney effect. However, the two mechanisms may also occur simultaneously. The determination of wind induced ventilation flows in industrial buildings may be performed through wind tunnel tests, with measurement of discharge velocity at openings, or else, with measurement of the pressure coefficients at the face of the buildings, where the openings are located. The methodology which employs the pressure coefficients requires the use of a theoretical model to calculate the flows, being the conventional way of using the wind tunnel as a tool in the ventilation project. The objective of this work is to evaluate the experimental procedures previously mentioned in order to be able to calculate the wind induced ventilation flows in industrial buildings. To reach this objective, two reduced models of an industrial building were tested at a geometric scale 1:200; one without openings, for the measurement of the pressure coefficients, and the other with ventilation openings with variable area, for the measurement of the wind velocities by the use of hot-wire anemometer. Different opening combinations were also tested and the flows analyzed. It is concluded that the opening types and the different flows exert a big influence in the ventilation flows and, therefore, in the natural ventilation itself. Also, the direct velocity measurement technique, through hot-wire anemometer, allows the ventilation flows to obtained directly, without interactions, being the results compatible with the theoretical models based on pressure differences.
22

Ventilação natural por efeito chaminé : estudo em modelo reduzido de pavilhões industriais / Natural ventilation for buoyancy - study of model reduced of industrial pavilions

Chiarello, Juliana Ana January 2006 (has links)
A ventilação nas edificações tem por objetivo principal criar um ambiente interno confortável e saudável, preservando a qualidade do ar interior. Um dos principais sistemas de renovação do ar, e praticamente a única opção economicamente viável, utilizado no projeto de ambientes industriais é a ventilação natural. Esta pode ser promovida por dois mecanismos: o denominado efeito chaminé e o efeito dos ventos, porém também podem ocorrer pelos dois simultaneamente. O objetivo deste trabalho é pesquisar a viabilidade do emprego de modelos reduzidos no projeto da ventilação natural em pavilhões industriais, considerando unicamente o efeito chaminé. Para atingir esse objetivo foi ensaiado um modelo, com escala geométrica 1/100, de um pavilhão industrial real situado na cidade de Passo Fundo – RS, que será utilizado como uma fábrica para injeção de alumínio em carcaças e rotores elétricos. Nos ensaios foram medidas velocidades na abertura de saída, com anemômetro de fio quente, e temperaturas com termopares, tanto dentro como fora do modelo. Os resultados alcançados permitem avaliar quais são as leis de semelhança relevantes neste tipo de ensaio com modelo reduzido, as limitações do procedimento experimental e, ainda, determinar valores de vazões de ar nas aberturas de saída e compará-los com vazões obtidas através da utilização de alguns modelos teóricos. / The ventilation in the constructions has for main objective to create a comfortable and healthful internal environment, preserving the quality of the interior air. One of the main systems of renewal of air, and practically the only economically viable option, used in the industrial environment project is the natural ventilation. This can be promoted by two mechanisms: the called buoyancy and the effect of the winds, however also can occur for the two simultaneously. The objective of this work is to search the viability of the job of models reduced in the project of the natural ventilation in industrial pavilions, considering solely the buoyancy. To reach this objective a model was assayed, with geometric scale 1/100, of a situated real industrial pavilion in the city of Passo Fundo – RS, that will be used as a plant for injection of aluminum in carcasses and electric rotors. In the assays speeds in the exit opening had been measured, with anemometer of hot wire, and temperatures with thermocouples, in such a way inside as it are of the model. The reached results allow to evaluate which are the excellent laws of similarity in this type of assay with reduced model, the limitations of the experimental procedure and still to determine values of air outflows in the exit openings and to compare them with outflows gotten through the use of some theoretical models.
23

Análise do plano diretor local visando auxiliar na decisão de parâmetros urbanísticos mais adequados em relação à ventilação natural : estudo de caso : setor Park Sul - Guará – DF

Arboés, Louyse Guide Veiga 30 June 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, Programa de Pós-Graduação em Arquitetura e Urbanismo, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-08-07T14:53:10Z No. of bitstreams: 1 2017_LouyseGuideVeigaArboés.pdf: 5207232 bytes, checksum: 57318b97227e14f75206eb6b9983820e (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-09-12T16:24:23Z (GMT) No. of bitstreams: 1 2017_LouyseGuideVeigaArboés.pdf: 5207232 bytes, checksum: 57318b97227e14f75206eb6b9983820e (MD5) / Made available in DSpace on 2017-09-12T16:24:24Z (GMT). No. of bitstreams: 1 2017_LouyseGuideVeigaArboés.pdf: 5207232 bytes, checksum: 57318b97227e14f75206eb6b9983820e (MD5) Previous issue date: 2017-09-12 / Esta dissertação aborda a eficiência da ventilação natural para diferentes parâmetros urbanísticos em geral contidos no Plano Diretor Local que definem a forma urbana e do edifício por meio de atributos morfológicos como afastamento entre as construções, verticalidade, porosidade, rugosidade, tomando como estudo de caso o Setor Park Sul, localizado na Região Administrativa do Guará, Distrito Federal. Foram coletados dados e valores relativos aos parâmetros urbanísticos tais como coeficiente de aproveitamento, taxa de ocupação, área do lote, altura máxima permitida, afastamentos obrigatórios, definida uma malha de análise e em seguida aplicado o método de avaliação na situação existente (cenário A – Edifícios verticalizados de até 11 pavimentos muito próximos uns aos outros com área central do lote livre). Logo após, foram criados novos cenários substituindo valores de coeficiente de aproveitamento (Cenário B – Edifícios na mesma disposição, porém mais baixos, totalizando 6 pavimentos) e taxa de ocupação (Cenário C – Edifícios de 4 pavimentos distribuídos uniformemente no lote) e então analisados e comparados. Os cenários B e C apresentaram os melhores resultados em relação à ventilação natural comparativamente ao Cenário A, pois assim o vento consegue recuperar a velocidade e permear em todas as partes do lote. Dessa forma, foi constatado que a substituição de um parâmetro do Plano Diretor Local pode modificar completamente a configuração espacial de determinada porção urbana podendo ser utilizada como estratégia de aproveitamento da ventilação natural. / This dissertation addresses the importance of efficient natural ventilation to establish different urban parameters taken into consideration by local master plans. They shape urban settings and buildings through morphological attributes such as building offsets, height limits, porosity, and rugosity. Setor Park Sul was chosen for the case study in question, located in Guará, an administrative region in Distrito Federal, where we collected data and values related to urban parameters, namely utilization coefficient, density, plot area, maximum allowable building height, and minimum offsets. An analysis grid was then defined to evaluate, analyze, and compare the three proposed conditions: Scenario A: high-rise buildings (up to 11 stories), all placed in close proximity to an open central area; Scenario B: mid-rise buildings (maximum 6 stories) distributed in an identical layout and density; Scenario C: low-rise (4 stories) buildings distributed evenly on the available plot; Scenarios B and C presented the best natural ventilation results with a wind speed capable of permeating all parts of the plot. Thus, it was found that the replacement of a single parameter can completely transform the spatial configuration of a given urban setting, which can be deployed as a strategy to maximize the benefits inherent to natural ventilation.
24

Determinação dos efeitos da vizinhança na eficiência dos sitemas de ventilação natural em pavilhões industriais / Determination of the neighborhood effects in the natural ventilation systems efficiency in industrial pavilions

Klein, Gustavo Menna Barreto January 2012 (has links)
Criar fontes alternativas de produção de energia, que não dependam principalmente do consumo de combustíveis fósseis, é o desafio do século XXI. Os sistemas de ventilação natural são um exemplo de técnicas construtivas que contribuem para o conforto ambiental de uma edificação, dispensando o consumo de energia para o seu funcionamento. Em ambientes industriais, muitas vezes, estes sistemas de ventilação tornam-se a única alternativa economicamente viável. Para um sistema de ventilação natural funcionar eficientemente, é necessário conhecer os diversos fatores que o influenciam. Dentre eles, o adequado dimensionamento das aberturas da edificação, a correta estimativa para os cálculos de vazão, para a renovação do ar, vinculada ao tipo de uso dos ambientes e, principalmente, os efeitos aerodinâmicos aos quais a edificação está submetida. A ação do vento é outro fator preponderante para que um sistema de ventilação natural cumpra com sua função em um edifício. Com isso, torna-se igualmente importante conhecer a influência que o entorno imediato pode exercer em relação ao escoamento do vento. O objetivo deste trabalho foi, portanto, analisar estes fatores, assim como determinar os efeitos de interferência aerodinâmica da vizinhança na eficiência dos sistemas de ventilação natural, aplicando estes conhecimentos em um estudo de caso de um pavilhão industrial. Para tal, procedeu-se uma análise teórica, com base na literatura existente e em normas vigentes, e uma análise experimental, através de modelos reduzidos, os quais foram ensaiados no túnel de vento Prof. Joaquim Blessmann, do Laboratório de Aerodinâmica das Construções – LAC, da Universidade Federal do Rio Grande do Sul - UFRGS. A análise experimental mostrou que a proximidade das construções vizinhas gera desempenhos diversos na vazão das aberturas do pavilhão em estudo, e variam conforme a orientação da fachada em relação ao ângulo de incidência do vento e a distância da vizinhança. Os efeitos da interferência são evidenciados em estruturas localizadas a uma distância menor que 10 vezes a dimensão da estrutura normal à ação do vento. / The creation of alternative energy sources, which do not depend on the consumption of fossil fuels, is the challenge of the XXI century. The natural ventilation systems are an example of construction techniques that contribute to the environmental comfort of a building. These ventilation systems often become the only viable alternative in industrial environments. The correct operation of a natural ventilation system depends of various factors. The appropriate sizing of the openings of the building and the correct estimate for the flow calculations are some of them. The action of the wind is another factor that interferes the working of the natural ventilation system in a building. Thus, it is also important to know the influence that the next surroundings can cause in the wind flow. The goal of this work was analyze these factors and determine the inference effects caused by the next buildings in the natural ventilation systems. This study includes a case study of an industrial building, a theoretical analysis based on existing literature and current regulations and experimental analysis using a reduced model. The reduced model was tested in the Prof. Joaquim Blessmann wind tunnel, in the Laboratório de Aerodinâmica das Construções – LAC, da Universidade Federal do Rio Grande do Sul/Brasil. The experimental analysis showed that the distance from neighboring buildings to industrial building in study generates different results and its vary according to the orientation of the building facade to the angle of wind incidence.
25

Estudos exploratórios sobre ventilação natural por tubos enterrados

Musskopf, Diego Boschetti January 2006 (has links)
O uso do solo como massa inercial para condicionamento térmico de edificações por contato direto é uma prática antiga, porém, seu uso como trocador de calor através de dutos enterrados, para ventilação natural de edificações é recente. A prática consiste em enterrar dutos a profundidades entre 0,5m e 1,5m – com extensões e diâmetros variáveis – por onde o ar circula do exterior para o interior dos ambientes através da ação do vento externo e da convecção natural. Durante o trajeto, o ar troca calor com o solo e ingressa no ambiente a temperaturas mais amenas. Embora seja um sistema já empregado na arquitetura bioclimática, existem poucos estudos conclusivos sobre a sua real eficácia. Dessa forma, o objetivo do trabalho é investigar o comportamento higrotérmico de uma edificação construída no sul do Brasil com o sistema e compreender a atuação dos fatores climáticos responsáveis pelo deslocamento de ar no seu interior. O estudo foi realizado através do monitoramento do Protótipo Ventura, localizado em Viamão (Brasil – 30º01'59"S, 51º13'48"W) no período de verão. No deslocamento de ar, foi estudada a influência do vento e da diferença de temperatura nos 2 diâmetros, nas 2 inclinações e nas 2 orientações dos dutos existentes, bem como a influência da chaminé solar. O desempenho higrotérmico foi avaliado comparando o ar na sala ventilada com uma sala de referência (de mesmas dimensões, porém de orientação distinta) e com o exterior. Os resultados demonstram que o solo de Viamão é eficiente para o condicionamento térmico da edificação, pois a pequenas profundidades, ele apresenta uma temperatura mais estável que o ar, próxima à média anual de temperatura do ar local (18ºC). Dessa forma, ao passar pelo duto, o ar externo é aquecido nos períodos frios e refrigerado nos períodos quentes, mantendo o ar interno próximo da zona de conforto. Também foi possível observar que o principal fator responsável pelo deslocamento de ar observado é o vento externo, porém as diferenças de temperatura entre as extremidades dos tubos, bem como entre o interior e exterior da edificação, não podem ser desprezadas, pois geram velocidades de mesma magnitude que o primeiro. Por fim, conclui-se que a ventilação da sala reduziu seu retardo térmico, porém não prejudicou o seu conforto térmico, apresentando inclusive uma redução de sua umidade interna. / The use of the ground as an inertial mass for thermal conditioning of buildings, such as the Italians cellars, is an old practice. However, its use as a heat exchanger with buried pipes for natural indoor ventilation is quite recent. The system uses pipes with variable length and diameter buried at a depth between 0.5m and 1.5m. The air flows trough the pipes from the outside to the inside by convection or wind effects. Although it’s already a bioclimatic architecture system, there are few conclusive studies about its real effectiveness. The objective of this study is to investigate the benefits of natural ventilation through buried pipes in a building located in the south of Brazil. A prototype building and a buried pipe system have been built and measured during a period in the summer of 2005-2006, in Viamão (30º 01'59"S, 51º13'48"W). The influence of the pipes diameter, inclination and orientation has been studied as well as the thermal comfort indoors. The system is efficient for thermal building conditioning and air renovation. At small depths, the ground presents a more steady temperature than the air, close to the annual average temperature (18ºC), cooling the air in hot days, warming it in cold nights – a similar effect is expected on a yearly period. The main factor responsible to the air flow is the outside wind, but the air temperature differences between the pipes, the room and the solar chimney edges are very relevant. The room ventilation reduces its thermal delay without interfering with its thermal performance, and also shows a decrease in its internal humidity.
26

Estudo da ventilação natural por efeito do vento em pavilhões industriais utilizando modelos reduzidos / The use of reduced models in the study of wind induced natural ventilation in industrial buildings

Nunes, Daniel Alexandre January 2006 (has links)
A ventilação natural pode ser promovida por dois mecanismos: o denominado efeito chaminé e o efeito dos ventos, porém também podem ocorrer os dois mecanismos simultaneamente. A determinação das vazões de ventilação por efeito do vento, em pavilhões industriais, pode ser realizada a partir de ensaios de modelos reduzidos em túnel de vento, com medição das velocidades do escoamento nas aberturas, ou então, com medição dos coeficientes de pressão em modelos fechados, nas faces onde estão localizadas as aberturas. A metodologia com medição dos coeficientes de pressão, que exige o emprego de um modelo teórico para calcular as vazões, é a forma convencional de usar o túnel de vento como ferramenta no projeto de ventilação. O objetivo deste trabalho é avaliar os procedimentos citados, para calcular as vazões de ventilação por efeito do vento em pavilhões industriais. Para atingir esse objetivo foram ensaiados em túnel de vento dois modelos reduzidos (escala geométrica 1:200) de um pavilhão industrial: um sem aberturas, para a medição dos coeficientes de pressão, e outro, com aberturas de ventilação de área variável, para a medição das velocidades do vento com anemômetro de fio quente. Além da comparação das duas metodologias para determinação das vazões de ventilação, os resultados dos ensaios foram também utilizados para analisar as alterações nas vazões de ventilação e nas velocidades do escoamento do ar decorrentes do fechamento de algumas aberturas do modelo estudado. Conclui-se que as aberturas localizadas na cumeeira e o tipo de escoamento exercem grande influência nas vazões de ventilação. A utilização da metodologia de medição direta de velocidades através de anemômetro de fio quente permite a obtenção de vazões de ventilação sem iterações, com resultados compatíveis com os modelos teóricos que se baseiam na diferença de pressões externas e internas. / Natural ventilation in industrial buildings may be promoted by two mechanisms: one due to wind effects and other called chimney effect. However, the two mechanisms may also occur simultaneously. The determination of wind induced ventilation flows in industrial buildings may be performed through wind tunnel tests, with measurement of discharge velocity at openings, or else, with measurement of the pressure coefficients at the face of the buildings, where the openings are located. The methodology which employs the pressure coefficients requires the use of a theoretical model to calculate the flows, being the conventional way of using the wind tunnel as a tool in the ventilation project. The objective of this work is to evaluate the experimental procedures previously mentioned in order to be able to calculate the wind induced ventilation flows in industrial buildings. To reach this objective, two reduced models of an industrial building were tested at a geometric scale 1:200; one without openings, for the measurement of the pressure coefficients, and the other with ventilation openings with variable area, for the measurement of the wind velocities by the use of hot-wire anemometer. Different opening combinations were also tested and the flows analyzed. It is concluded that the opening types and the different flows exert a big influence in the ventilation flows and, therefore, in the natural ventilation itself. Also, the direct velocity measurement technique, through hot-wire anemometer, allows the ventilation flows to obtained directly, without interactions, being the results compatible with the theoretical models based on pressure differences.
27

Determinação dos efeitos da vizinhança na eficiência dos sitemas de ventilação natural em pavilhões industriais / Determination of the neighborhood effects in the natural ventilation systems efficiency in industrial pavilions

Klein, Gustavo Menna Barreto January 2012 (has links)
Criar fontes alternativas de produção de energia, que não dependam principalmente do consumo de combustíveis fósseis, é o desafio do século XXI. Os sistemas de ventilação natural são um exemplo de técnicas construtivas que contribuem para o conforto ambiental de uma edificação, dispensando o consumo de energia para o seu funcionamento. Em ambientes industriais, muitas vezes, estes sistemas de ventilação tornam-se a única alternativa economicamente viável. Para um sistema de ventilação natural funcionar eficientemente, é necessário conhecer os diversos fatores que o influenciam. Dentre eles, o adequado dimensionamento das aberturas da edificação, a correta estimativa para os cálculos de vazão, para a renovação do ar, vinculada ao tipo de uso dos ambientes e, principalmente, os efeitos aerodinâmicos aos quais a edificação está submetida. A ação do vento é outro fator preponderante para que um sistema de ventilação natural cumpra com sua função em um edifício. Com isso, torna-se igualmente importante conhecer a influência que o entorno imediato pode exercer em relação ao escoamento do vento. O objetivo deste trabalho foi, portanto, analisar estes fatores, assim como determinar os efeitos de interferência aerodinâmica da vizinhança na eficiência dos sistemas de ventilação natural, aplicando estes conhecimentos em um estudo de caso de um pavilhão industrial. Para tal, procedeu-se uma análise teórica, com base na literatura existente e em normas vigentes, e uma análise experimental, através de modelos reduzidos, os quais foram ensaiados no túnel de vento Prof. Joaquim Blessmann, do Laboratório de Aerodinâmica das Construções – LAC, da Universidade Federal do Rio Grande do Sul - UFRGS. A análise experimental mostrou que a proximidade das construções vizinhas gera desempenhos diversos na vazão das aberturas do pavilhão em estudo, e variam conforme a orientação da fachada em relação ao ângulo de incidência do vento e a distância da vizinhança. Os efeitos da interferência são evidenciados em estruturas localizadas a uma distância menor que 10 vezes a dimensão da estrutura normal à ação do vento. / The creation of alternative energy sources, which do not depend on the consumption of fossil fuels, is the challenge of the XXI century. The natural ventilation systems are an example of construction techniques that contribute to the environmental comfort of a building. These ventilation systems often become the only viable alternative in industrial environments. The correct operation of a natural ventilation system depends of various factors. The appropriate sizing of the openings of the building and the correct estimate for the flow calculations are some of them. The action of the wind is another factor that interferes the working of the natural ventilation system in a building. Thus, it is also important to know the influence that the next surroundings can cause in the wind flow. The goal of this work was analyze these factors and determine the inference effects caused by the next buildings in the natural ventilation systems. This study includes a case study of an industrial building, a theoretical analysis based on existing literature and current regulations and experimental analysis using a reduced model. The reduced model was tested in the Prof. Joaquim Blessmann wind tunnel, in the Laboratório de Aerodinâmica das Construções – LAC, da Universidade Federal do Rio Grande do Sul/Brasil. The experimental analysis showed that the distance from neighboring buildings to industrial building in study generates different results and its vary according to the orientation of the building facade to the angle of wind incidence.
28

Rustificação in vitro de Lippia grata Schauer : Iluminação de lâmpadas LED x ventilação natural

ZÁRATE-SALAZAR, Jhonatan Rafael 27 February 2018 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2018-05-22T14:09:49Z No. of bitstreams: 1 Jhonatan Rafael Zarate Salazar.pdf: 1419077 bytes, checksum: 2cc1c98bd40a57ff0cca74ab8c0e6f4e (MD5) / Made available in DSpace on 2018-05-22T14:09:50Z (GMT). No. of bitstreams: 1 Jhonatan Rafael Zarate Salazar.pdf: 1419077 bytes, checksum: 2cc1c98bd40a57ff0cca74ab8c0e6f4e (MD5) Previous issue date: 2018-02-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Lippia grata Schauer is an aromatic species, endemic to the Brazilian Northeast and of recognized medicinal importance due to the anti-inflammatory, antioxidant and antimicrobial activity present in its essential oils, making it a promising natural resource in the treatment of diseases. In vitro cultivation could make the use of its medicinal potential more efficient without the need to affect its natural habitat by anthropogenic actions. In this sense, the present research aimed to evaluate, with a morphophysiological and biochemical focus, L. grata plants grown in vitro under the use of LED lamps associated with natural ventilation in the flasks. The experimental units were constituted by nodal segments of L. grata, 1 cm long, removed below the apical bud and inoculated in flasks containing 10 mL of MS nutrient medium supplemented with 30 g L-1 of sucrose, gelled with 2.5 g L-1 phytagel and pH adjusted to 5.7. The natural ventilation of the flasks was controlled by two types of partial (ventilation) and total (non-ventilation) seals, distributed randomly in four different lighting systems, LVA 5: 1 = Red and Blue LEDs (5: 1) ; LVA 1: 1 = Red and Blue LEDs (1: 1); LB = White LED and FL = Fluorescent Lamp, calibrated at 60 μmol m - 2 s - 1 of luminous intensity inside a growth room with photoperiod of 16 hours, 80 ± 5% relative humidity and temperature of 25 ± 2 ° C , for 45 days, under a completely randomized design (DIC), with a 4x2 factorial arrangement, with 3 replicates, each replicate being 15 experimental units. On the 45th day, the plants were analyzed according to their biometric, biochemical and histological parameters. In this sense, we show that the natural ventilation of the flasks reduces the incidence of hyperhydric leaves in all lighting systems by 62%, presenting larger plants and more expanded leaves, and in these conditions the plants reduced their fresh mass by 27% indirectly evidencing the effect of gaseous exchange. The biochemical parameters of the plants were also positively influenced by the natural ventilation of the weak ones, since the contents of chloroplastídicos pigments and total soluble carbohydrates contents increased by 46% and 115%, respectively. In addition, under a histological approach we observed that there was a greater cellular organization of the epidermis and cortical parenchyma of the main leaf vein, a situation that was not observed in plants with conditions without ventilation. The influence of the lighting systems was also remarkable, especially the White LED, since it presented plants with less number of hyperhydric leaves even in non-ventilated bottles, which translates into a larger number of normal leaves, in addition to showing a greater number of shoots and roots. Also, the White LED associated with natural ventilation conditions was the only lighting system that promoted significant increases in chlorophyll a; chlorophyll b; total chlorophyll (a + b); carotenoids; total soluble carbohydrates; and sucrose in 87%; 143%; 102%; 76%; 223% and 116%, respectively, compared to that obtained under non-ventilated conditions. In view of this, we concluded that there is a synergistic effect in the use of White LED lamps associated with natural ventilation conditions of the weaker ones in the in vitro culture of L. grata as they contribute to the reduction of hyperhydric symptoms and stimulate a greater metabolic activity expressed through increase in their biochemical parameters. / Lippia grata Schauer é uma espécie aromática, endêmica do Nordeste brasileiro e de reconhecida importância medicinal devido à atividade anti-inflamatória, antioxidante e antimicrobiana presentes em seus óleos essenciais, fazendo dela um recurso natural promissor no tratamento de doenças. O cultivo in vitro poderia tornar mais eficiente o uso de suas potencialidades medicinais sem a necessidade de afetar seu habitat natural por ações antropogênicas. Nesse sentido, o presente trabalho de investigação objetivou avaliar com enfoque morfofisiológico e bioquímico, plantas de L. grata cultivadas in vitro sob o uso de lâmpadas LED’s associadas à ventilação natural nos frascos. As unidades experimentais foram constituídas por segmentos nodais de L. grata, com 1 cm de comprimento, retirados abaixo da gema apical e inoculadas em frascos contento 10 mL de meio nutritivo MS suplementado com 30 g L-1 de sacarose, gelificado com 2,5 g L-1 phytagel e pH ajustado a 5,7. A ventilação natural dos frascos foi controlada por meio de dois tipos de vedação, parcial (com ventilação) e total (sem ventilação), distribuídos aleatoriamente em quatro diferentes sistemas de iluminação, LVA 5:1= LED Vermelha e Azul (5:1); LVA 1:1= LED Vermelha e Azul (1:1); LB= LED Branco e FL= Lâmpada Fluorescente, calibradas em 60 μmol m− 2 s – 1 de intensidade luminosa dentro de uma sala de crescimento com fotoperíodo de 16 horas, 80±5% de umidade relativa e temperatura de 25±2°C, durante 45 dias, conduzidas sob um delineamento inteiramente casualizado (DIC), com um arranjo fatorial 4x2, com 3 repetições, sendo cada repetição 15 unidades experimentais. No 45° dia, as plantas foram analisadas em função dos seus parâmetros biométricos, bioquímicos e histológicos. Nesse sentido, evidenciamos que a ventilação natural dos frascos reduz em 62% a incidência de folhas hiperídricas em todos os sistemas de iluminação apresentando plantas de maior tamanho e folhas mais expandidas, ademais nessas condições as plantas reduziram sua massa fresca em 27% evidenciando indiretamente o efeito do intercâmbio gasoso. Os parâmetros bioquímicos das plantas também foram influenciados positivamente pela ventilação natural dos fracos uma vez que os teores dos pigmentos cloroplastídicos e teores de carboidratos solúveis totais aumentaram em 46% e 115%, respectivamente. Ademais, sob um enfoque histológico observamos que houve uma maior organização celular da epiderme e do parênquima cortical da nervura principal das folhas, situação que não foi observada em plantas com condições sem ventilação. A influência dos sistemas de iluminação também foi destacável, em especial do LED Branco uma vez que apresentou plantas com menor número de folhas hiperídricas mesmo em frascos sem ventilação o qual se traduz em um maior número de folhas normais aliás de exibir maior número de brotos e raízes. Assim mesmo, o LED Branco associado a condições de ventilação natural foi o único sistema de iluminação que promoveu expressivos aumentos nos teores de clorofila a; clorofila b; clorofila totais (a+b); carotenoides; carboidratos solúveis totais; e sacarose em 87%; 143%; 102%; 76%; 223% e 116%, respectivamente, comparado com o obtido em condições sem ventilação. Perante isto, concluímos que existe um efeito sinérgico no uso de lâmpadas LED Brancas associadas a condições de ventilação natural dos fracos no cultivo in vitro de L. grata uma vez que contribuem na redução nos sintomas de hiperidricidade e estimulam uma maior atividade metabólica expressada através do aumento dos teores em seus parâmetros bioquímicos.
29

Análise numérica da influência de configurações de aberturas da fachada e do mobiliário na ventilação natural em ambientes de escritórios. / Numerical analysis of the influence of facade openings and furniture configurations on natural ventilation in office environments.

Flávio Bomfim Mariana 19 April 2013 (has links)
Com a disseminação do conceito de desenvolvimento sustentável tem sido verificado um aumento no interesse por sistemas de baixo ou nenhum consumo de energia. Uma forma de diminuir o consumo e propiciar condições de qualidade do ar e conforto térmico é utilizar a ventilação natural. No presente trabalho analisa-se a influência de diferentes tipos de janelas e mobiliário sobre as condições de ventilação natural em ambientes de escritório utilizando simulação numérica. O modelo é composto por um edifício de cinco pavimentos, sendo analisadas as condições térmicas do pavimento mais alto. A mudança do mobiliário apresentou tendência de piora das condições de conforto com o aumento das partições, sendo significativa com partições de 1,50m de altura e as demais condições menos propícias para a ventilação natural. Não foi observada mudança significativa entre as partições de 0,90m e 1,10m, sendo preferível então a última pela melhor privacidade dos ocupantes. A modificação do layout não resultou em mudanças significativas de temperatura do ar no ambiente ocupado, salvo na configuração que reuniu as piores condições de ventilação. Já a geometria das janelas apresentou resultados significativamente diferentes, pois a janela maxim-ar permitiu a entrada de um volume maior de ar e o distribuiu melhor dentro dos ambientes de escritório simulados, em comparação com a janela de correr vertical. Verificou-se que a escolha adequada das janelas influencia o ambiente térmico de maneira semelhante à redução da iluminação e dos equipamentos que dissipam calor. Concluiu-se que com a implantação adequada da edificação, escolha correta das aberturas, da configuração do mobiliário e das cargas térmicas internas é possível utilizar sistemas de ventilação natural em ambientes de escritórios com bons resultados. Por fim, é importante destacar que a aplicação da dinâmica dos fluidos computacional (CFD) para ventilação natural é complexa, pois este fenômeno é naturalmente instável, com necessidade de bastante cuidado na definição dos modelos para representar o problema e no processo de simulação numérica. / Among the spread of the sustainability concept it has been found a rising interest on low or zero energy consumption systems. One approach to reduce energy consumption and also provide acceptable levels of indoor air quality and thermal comfort is using natural ventilation. On the present report it is analyzed the influence of different types of windows and furniture on natural ventilation conditions of office environments using numerical simulation. The model is a five storey building, being the thermal conditions evaluated in the highest floor. Furniture change presented a worsen tendency of the comfort conditions as the partitions height increased. This worsen was significant when 1.50m height partitions were combined with other features less propitious for natural ventilation. No significant change was found between the 0.90m and 1.10m height partitions, being the last preferable due to occupants privacy enhance. Layout modification did not result on significant changes of occupied zone air temperature, except on the set up that gathered the worse ventilation conditions. However, the different window geometries presented results significantly different, since the maxim-air window allowed the entrance of more wind and has distributed it better inside the simulated office environments. Therefore, thermal comfort conditions became better than in comparison with the vertical sliding windows. It was verified that the adequate choice of windows influences the thermal environment in a similar way to the reduction of lighting and equipments that dissipate heat. It was concluded that with the proper building implementation, correct choice of openings, furniture configuration and internal heat gains it is possible to use natural ventilation in office environments with good results. Finally, it is noteworthy the complexity in applying the computational fluid dynamics (CFD) for natural ventilation, since it is an inherently unstable phenomenon, requiring considerable care in defining the models to represent the problem and in the numerical simulation process.
30

Ventilação natural em edifícios multifamiliares do "Programa Minha Casa Minha Vida" / Evaluating natural ventilation in multi-storey social interest housing

Morais, Juliana Magna da Silva Costa, 1978- 12 June 2013 (has links)
Orientador: Lucila Chebel Labaki / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-24T22:56:46Z (GMT). No. of bitstreams: 1 Morais_JulianaMagnadaSilvaCosta_D.pdf: 13054552 bytes, checksum: 3d674839d2f59013f33b16741b5abe7a (MD5) Previous issue date: 2013 / Resumo: A ventilação natural é uma estratégia projetual que deve ser usada sempre que possível em países de clima quente como o Brasil, pois dentre suas vantagens está o conforto térmico e a economia de energia. O uso desta estratégia deve ser priorizado principalmente em projetos destinados à população de baixa renda como é o caso dos edifícios incluídos no "Programa Minha Casa Minha Vida"- PMCMV. O objetivo desta tese é discutir e ventilação natural no interior de edifícios multifamiliares do PMCMV em três tipologias arquitetônicas diferentes localizadas na cidade de Campinas/SP, no intuito de alertar os projetistas em geral de como pequenas decisões de projeto podem influenciar no conforto térmico dos usuários. Adotou-se o uso de simulação computacional da ventilação natural por meio de CFD (Computer Fluid Dynamics) como ferramenta capaz de realizar esta análise. Assim, primeiro realizou-se a seleção dos edifícios que serviram de estudo de caso e a consequente modelagem 3D destes, considerando suas aberturas. Posteriormente realizou-se caracterização climática dos ventos da cidade de Campinas/SP, para obtenção dos dados de entrada no CFD. Por fim, realizou-se a simulação computacional da ventilação natural nas três tipologias escolhidas como estudos de caso para três diferentes ângulos de incidência do vento (0º, 90º e 135º). Foram obtidos resultados quantitativos (velocidade média do vento em cada ambiente interno) e qualitativos (imagens do fluxo de ar externo e interno). Entre as três tipologias estudadas os resultados apontam para um melhor desempenho de ventilação interna no edifício da tipologia 1, com planta tipo "H", no qual a abertura localizada na grande reentrância representou papel determinante para tal. Na tipologia 2, com planta quadrada, comprovou-se que a solução projetual de ventilar banheiro e cozinha por meio de abertura localizada na área de serviço não é eficiente, portanto deve ser evitada pelos projetistas. Porém o pior desempenho foi verificado na tipologia 3 com planta retangular o qual apresenta maior fachada monolítica (sem reentrâncias). Os apartamentos mais prejudicados foram aqueles localizados na parte central do edifício, onde praticamente inexiste ventilação cruzada (e sim unilateral). Nas três tipologias o vento incidente oblíquo ao edifício (incidência de 135º) apresentou melhores resultados de velocidades do ar médias internas do que ventos incidentes à 0º e 90º. Assim, para estes edifícios deve-se buscar sempre que possível posicioná-los obliquamente em relação ao vento dominante local / Abstract: The natural ventilation is a project strategy that must be used always when possible, mainly in warm countries like Brazil, because among the advantages, it's the thermal comfort and energy economy. The use of such strategy must be prioritized mainly in projects that has objective to the low-incomes families, like the buildings included in the very know Brazilian social program "My House, My Life"¿ PMCMV. This thesis aims the discussion of the natural ventilation into the multifamily buildings to PMCMV in three different architectonics typologies localized in Campinas city ¿ SP, mainly to alert in general the projects makers, how the small project's decisions cans influence the thermal comfort of the people. It was adopted the use of computer simulation to the natural ventilation through CFD (Computer Fluid Dynamics), as the tool able to accomplishes such analysis. So, methodologically and first of all it was made the selection of the undertaken that were the focus of this case's research, and the consequent 3D modeling of those buildings considering their openings. In a second step, it was made the wind's climate characterization in Campinas, looking to obtain starting data to CFD. At the end, it was done the computer simulation to the natural ventilation for the threes typologies chosen as the case's study to the three different incident angles of the wind ( 0º,90º e 135º). It were obtained quantitative results (average speed to the wind in each internal environment) and qualitative (internal and external air flow images). Among the three typologies researched, the results points to the better performance for the internal ventilation in the building of the typology 1, with the plant kind "H", where the opening localized on the big reentrance showed important role to that. In the typology 2, it was concluded that the projectual solution to ventilate the bathroom and kitchen through the opening localized in the service area it wasn't efficient, therefore must be avoided by the architects. However, the worst performance was verified to the rectangular building with the bigger monolithic façade (without reentrances), mainly to the apartments localized in the central part of the building, where practically doesn't exist crossed ventilation (but unilateral). For the three typologies, the incident oblique wind to the building (incidence of 135º) showed better internal average air speed results than incidents winds of 0º e 90º. Therefore, to those buildings must be always when possible to focus positioning them in the oblique position in relation to the local dominant wind / Doutorado / Arquitetura, Tecnologia e Cidade / Doutora em Arquitetura, Tecnologia e Cidade

Page generated in 0.0539 seconds