• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 4
  • 3
  • Tagged with
  • 17
  • 13
  • 9
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Biomechanische Untersuchungen zur Steigerung der primären Verankerung zementfrei implantierbarer Revisionshüftpfannen

Klüss, Daniel January 2008 (has links)
Zugl.: Rostock, Univ., Diss., 2008
2

Biomechanische, morphologische und klinische Studien zum vorderen Kreuzbandersatz in Pressfit-Technik /

Schmidt-Wiethoff, Rüdiger. January 2005 (has links)
Zugl.: Köln, Dt. Sporthochsch., Habil.-Schr., 2004.
3

Interface- und Zementmantelanalyse zementierter Hüftendoprothesen unter dem Aspekt der frühzeitigen, aseptischen Prothesenlockerung am Tiermodell Schaf

Zander, Yvonne January 2009 (has links)
Zugl.: Giessen, Univ., Diss., 2009
4

Zur Krafteinleitung bei externer Vorspannung

Neuser, Jens Ulrich. Unknown Date (has links) (PDF)
Universiẗat, Diss., 2003--Bochum.
5

Untersuchungen zur Verbundverankerung textilbewehrter Feinbetonverstärkungsschichten für Betonbauteile / Investigations for the Bond Anchoring of Textile Reinforced Fine-grained Concrete Strengthening Layers of RC-Members

Ortlepp, Regine 15 August 2007 (has links) (PDF)
Die vorliegende Arbeit befasst sich mit der Verbundverankerung des neuen Verstärkungsmaterials textilbewehrter Beton für Stahlbetonbauteile. Der Detailpunkt der Verankerung mit den Mechanis-men der Kraftübertragung von der textilbewehrten Verstärkungsschicht in den Altbeton wurde auf experimentellem Weg an unterschiedlichen Probekörperformen untersucht. Dazu wurden verschie-dene Haftzug-, Filamentgarnauszug- sowie Schubversuche durchgeführt. Nach der Klärung der grundlegenden Phänomene beim Verbundbruchverhalten von Verstärkungs-schichten wurden zugehörige Versagenskriterien näher beleuchtet. Ein mögliches Versagen des inneren Verbundes wurde durch zusätzlich in das Versuchsprogramm aufgenommene Filamentgar-nauszugsversuche untersucht. Für die Verankerung sind zwei Versagensebenen zu berücksichtigen, die eine getrennte Betrachtung erfordern: der Altbetonuntergrund und die Ebene der textilen Be-wehrung. Mit Hilfe experimenteller Haftzuguntersuchungen wurde ein breit gefächertes Spektrum möglicher Einflussparameter auf die Tragfähigkeit des Verbundes in der Ebene der textilen Bewehrung unter-sucht. Den einzelnen Einflussfaktoren kommt dabei eine unterschiedliche Bedeutung zu. Den aus-schlaggebenden Einfluss auf die Tragfähigkeit des Haftverbundes in der Ebene der textilen Bewehrung liefert die textile Bewehrung selbst. Es wurde ein geeignetes Verfahren zur Ermittlung eines wirksamen Flächenanteiles der textilen Bewehrungsstrukturen entwickelt, welches die Grund-lage für die weiterführenden Betrachtungen zum Verbundversagen durch Delamination in der Ebe-ne der textilen Bewehrung bildet. Das Verbundtragverhalten unter Schubbeanspruchung bildet den Kern der vorliegenden Arbeit. Spezielle Eigenheiten des textilbewehrten Betons werden aufgezeigt und Lösungsvorschläge erar-beitet. Da sich das Verhalten von Verstärkungsschichten aus textilbewehrtem Feinbeton beträcht-lich von bekannten Klebeverbindungen unterscheidet, sind hier völlig neue Wege zu beschreiten. In Zusammenarbeit mit dem Institut für Photogrammetrie und Fernerkundung wurde ein neues, riss-bildorientiertes Messverfahren entwickelt. Anhand eines Beispielversuchs wird diese neu entwi-ckelte Methode vorgestellt und verbleibende Problempunkte diskutiert. Die Ergebnisse dieser Messungen haben gezeigt, dass es mit dem derzeitigen Kenntnisstand nicht möglich ist, für das Verstärkungsmaterial Textilbeton eine Schubspannungs-Schlupf-Beziehung anzugeben. Nach An-sicht der Verfasserin ist die Verwendung einer solchen Modellvorstellung nur für Verstärkungsma-terialien mit linear-elastischem Materialverhalten geeignet. In der vorliegenden Arbeit werden einige alternative Modellvorschläge für die Beschreibung des Verbundverhaltens angegeben. Separate Modellvorschläge für die Verbundtragfähigkeit unter Haft-zugbeanspruchung und unter Schubbeanspruchung wurden zu einer Interaktion zusammengeführt. Diesem wurden weitere alternative Modellvorschläge wie z. B. die Betrachtung als Stabwerk mit veränderlicher Druckstrebenneigung gegenübergestellt.
6

Untersuchungen zur Verbundverankerung textilbewehrter Feinbetonverstärkungsschichten für Betonbauteile

Ortlepp, Regine 13 July 2007 (has links)
Die vorliegende Arbeit befasst sich mit der Verbundverankerung des neuen Verstärkungsmaterials textilbewehrter Beton für Stahlbetonbauteile. Der Detailpunkt der Verankerung mit den Mechanis-men der Kraftübertragung von der textilbewehrten Verstärkungsschicht in den Altbeton wurde auf experimentellem Weg an unterschiedlichen Probekörperformen untersucht. Dazu wurden verschie-dene Haftzug-, Filamentgarnauszug- sowie Schubversuche durchgeführt. Nach der Klärung der grundlegenden Phänomene beim Verbundbruchverhalten von Verstärkungs-schichten wurden zugehörige Versagenskriterien näher beleuchtet. Ein mögliches Versagen des inneren Verbundes wurde durch zusätzlich in das Versuchsprogramm aufgenommene Filamentgar-nauszugsversuche untersucht. Für die Verankerung sind zwei Versagensebenen zu berücksichtigen, die eine getrennte Betrachtung erfordern: der Altbetonuntergrund und die Ebene der textilen Be-wehrung. Mit Hilfe experimenteller Haftzuguntersuchungen wurde ein breit gefächertes Spektrum möglicher Einflussparameter auf die Tragfähigkeit des Verbundes in der Ebene der textilen Bewehrung unter-sucht. Den einzelnen Einflussfaktoren kommt dabei eine unterschiedliche Bedeutung zu. Den aus-schlaggebenden Einfluss auf die Tragfähigkeit des Haftverbundes in der Ebene der textilen Bewehrung liefert die textile Bewehrung selbst. Es wurde ein geeignetes Verfahren zur Ermittlung eines wirksamen Flächenanteiles der textilen Bewehrungsstrukturen entwickelt, welches die Grund-lage für die weiterführenden Betrachtungen zum Verbundversagen durch Delamination in der Ebe-ne der textilen Bewehrung bildet. Das Verbundtragverhalten unter Schubbeanspruchung bildet den Kern der vorliegenden Arbeit. Spezielle Eigenheiten des textilbewehrten Betons werden aufgezeigt und Lösungsvorschläge erar-beitet. Da sich das Verhalten von Verstärkungsschichten aus textilbewehrtem Feinbeton beträcht-lich von bekannten Klebeverbindungen unterscheidet, sind hier völlig neue Wege zu beschreiten. In Zusammenarbeit mit dem Institut für Photogrammetrie und Fernerkundung wurde ein neues, riss-bildorientiertes Messverfahren entwickelt. Anhand eines Beispielversuchs wird diese neu entwi-ckelte Methode vorgestellt und verbleibende Problempunkte diskutiert. Die Ergebnisse dieser Messungen haben gezeigt, dass es mit dem derzeitigen Kenntnisstand nicht möglich ist, für das Verstärkungsmaterial Textilbeton eine Schubspannungs-Schlupf-Beziehung anzugeben. Nach An-sicht der Verfasserin ist die Verwendung einer solchen Modellvorstellung nur für Verstärkungsma-terialien mit linear-elastischem Materialverhalten geeignet. In der vorliegenden Arbeit werden einige alternative Modellvorschläge für die Beschreibung des Verbundverhaltens angegeben. Separate Modellvorschläge für die Verbundtragfähigkeit unter Haft-zugbeanspruchung und unter Schubbeanspruchung wurden zu einer Interaktion zusammengeführt. Diesem wurden weitere alternative Modellvorschläge wie z. B. die Betrachtung als Stabwerk mit veränderlicher Druckstrebenneigung gegenübergestellt.
7

Structure and function of root systems at different altitudes of a south Ecuadorian montane forest

Soethe, Nathalie 13 February 2007 (has links)
Es wurden Wurzelsysteme auf 1900, 2400 und 3000 m eines südecuadorianischen Bergregenwaldes untersucht. Ziel war es, ein besseres Verständnis über den Einfluss der Höhenstufe auf die Wurzelfunktionen Nährstoffaneignung und Verankerung sowie Speicherung von C und Nährstoffen in der Wurzelbiomasse zu erlangen. Auf 2400 und 3000 m nahmen die Wurzellängendichten (WLD) mit zunehmender Bodentiefe schneller ab als auf 1900 m. Die vertikale Verteilung der N-Aufnahme war ähnlich der Verteilung der WLD. Das Nährstoffaneignungsvermögen war also in größerer Meereshöhe deutlich mehr auf die organische Auflage konzentriert war als auf 1900 m. Nährstoffkonzentrationen in Blättern zeigten, dass auf 1900 m das Pflanzenwachstum nicht durch Nährstoffmangel limitiert war, während auf 2400 und 3000 m v. a. N, aber auch P, S und K das Pflanzenwachstum limitierten. Die schlechte Nährstoffversorgung der Pflanzen in großer Meereshöhe war vermutlich auf langsame Mineralisation organisch gebundener Nährstoffe und auf ein geringes Nährstoffaneignungsvermögen aus tieferen Bodenschichten zurückzuführen. Die Wurzelbiomasse war auf 3000 m höher als in niedrigerer Meereshöhe. Die Bedeutung des Wurzelsystems für die C-Speicherung stieg also mit zunehmender Höhenstufe. Auch Vorräte an N, S, K, Ca und Mg in den Wurzeln waren auf 3000 m am höchsten. Die Grobwurzelsysteme der Bäume wiesen auf allen Höhenstufen Verankerungs-fördernde Merkmale auf. Bäume auf 3000 m bildeten flachgründigere Wurzelteller als auf 1900 m. Wurzeleigenschaften, die die horizontale Ausdehnung des Wurzeltellers fördern, waren auf 3000 m häufiger oder ausgeprägter als auf 1900 m. Es wird gefolgert, dass eine gehemmte Tiefendurchwurzelung des Bodens in größerer Meereshöhe sowohl das Nährstoffaneignungsvermögen als auch auf die Verankerung der Bäume verringerte. Die hohe Biomasseallokation in die Wurzeln in größerer Meereshöhe weist darauf hin, dass Umweltbedingungen hier besondere Anforderungen an die Wurzelfunktionen stellen. / Root systems at 1900, 2400 and 3000 m of a south Ecuadorian montane forest were investigated. The aim of this study was to improve our knowledge on the impact of altitude on the root functions nutrient acquisition, anchorage and storage of C and nutrients in root biomass. At 2400 and 3000 m, the decrease of root length densities (RLD) with increasing soil depth was more pronounced than at 1900 m. The vertical distribution of N uptake was similar to the vertical distribution of RLD. Thus, the ability for nutrient uptake was more concentrated to the organic surface layer at high altitudes than at 1900 m. Foliar nutrient concentrations showed that plant growth at 1900 m was not limited by nutrient deficiency. In contrast, at 2400 and 3000 m especially N, but also P, S and K limited plant growth. The decreased nutritional status of plants at high altitudes was caused by low mineralization rates of nutrients as well as low ability for nutrient acquisition from deeper soil layers. At 3000 m, root biomass was higher than at low altitudes. Hence, the importance of root systems for C sequestration increased with increasing altitude. Similarly, pools of N, S, K, Ca and Mg were higher at 3000 m than at 1900 and 2400 m. At all altitudes, coarse root systems of trees showed traits that are supposed to improve anchorage. At 3000 m, root soil plates were more superficial than at 1900 m. Root traits that improve the horizontal extension of root soil plates were more pronounced or occurred more often at 3000 m than at 1900 m. It is concluded that impeded rooting in deeper soil layers at high altitudes decreased both the ability for nutrient acquisition and anchorage. At high altitudes, the high allocation of biomass to the root systems showed that at these sites, environmental conditions enhanced the requirements to the functions of roots.
8

Anatomische "Hamstringsehnen" Verankerung mit Interferenzschrauben beim Kreuzbandersatz

Weiler, Andreas 03 December 2002 (has links)
Einleitung: Die Verwendung der Hamstringsehnen als Transplantate in der rekonstruktiven Chirurgie des vorderen Kreuzbandes stellt eine wenig invasive Alternative zur herkömmlichen Verwendung des mittleren Patellarsehnendrittels dar. Hier ist jedoch die Transplantatverankerung, die bisher meist extrakortikal, also weit entfernt der nativen Kreuzbandinsertion angelegt wurde problematisch. Hierdurch zeigt das Transplantat-Verankerungs-Konstrukt ein unbefriedigendes elastisches und plastisches Dehnungsverhalten, welches u.A. für eine geringere Kniestabilität und eine gestörte ossäre Transplantatintegration verantwortlich gemacht wird. Eine anatomiegerechte Transplantatverankerung auf Gelenkniveau könnte die mechanischen und biologischen Rahmenbedingungen verbessern, um so die Hamstringsehnen als Alternativtransplantat mit verbesserter klinischer Prognose einsetzten zu können. Eine direkte Verankerung mit Interferenzschrauben erlaubt eine solche anatomische Transplantatverankerung, so dass wir dieses neue Operationsverfahren biomechanisch und tierexperimentell untersucht haben. Methoden: In sechs biomechanischen Teilprojekten und in zwei tierexperimentellen Untersuchungen wurde die Eignung der direkten Verankerung mit biodegradierbaren Interferenzschrauben der Hamstringsehnen im Vergleich zu konventionellen Patellar- und Hamstringsehnen-Techniken untersucht. Ergebnisse: Wir konnten demonstrieren, dass die initiale femorale Verankerungsfestigkeit, auch in Sinne der sog. Hybridfixation ausreichend ist. Die tibiale Verankerung unterliegt jedoch verschiedenen Variablen und bedarf einer differenzierten klinischen Anwendung. Im Vergleich zu konventionellen Techniken der Hamstringsehnen-Verankerung kann das plastische und elastische Dehnungsverhalten durch die Verankerung mit Interferenzschrauben deutlich verbessert werden, wobei jedoch das mechanische Verhalten des Patellarsehnen-Transplantates nicht erreicht wurde. Die tierexperimentelle Analyse zeigt auf, dass die ossäre Integration durch die Kompression des Transplantates auf Gelenkniveau soweit verbessert werden kann, dass sog. Tunnelaufweitungen, als Zeichen einer gestörten Einheilung vermieden werden und, dass das Transplantat mit einer direkten Bandinsertion, entsprechend des nativen vorderen Kreuzbandes, auf Gelenkniveau einheilt. Schlussfolgerung: Die hier vorgelegten Untersuchungen haben erstmals umfassend die Rahmenbedingungen der Interferenzschrauben-Verankerung der Hamstringsehnen beschrieben; einer Technik die inzwischen weltweit verbreitete Anwendung findet. Durch eine anatomische Transplantatverankerung auf Gelenkniveau besteht nun die Möglichkeit, mit optimierten mechanischen und biologischen Rahmenbedingungen eine adäquate Alternativtechnik zur konventionellen Verwendung der Patellarsehnen anzubieten. / Introduction: The use of hamstring tendon grafts as a substitute for anterior cruciate ligament reconstruction presents a less invasive procedure compared to the conventional bone-patellar tendon- bone graft. Current techniques of hamstring tendon anterior cruciate ligament reconstruction utilise an extra-cortical fixation. An extra-cortical fixation, however, shows inferior structural parameters with respect to construct slippage or stiffness. These factors may contribute to less stable knees after reconstruction and a delayed osseous integration of the grafted tissue. An anatomic hamstring tendon graft fixation close to the joint line may overcome these problems and may present an alternative to the conventional bone-patellar tendon-bone graft by means of optimised mechanical and biological boundary conditions. We therefore studied anatomic interference fit fixation of hamstring tendon grafts in different mechanical and animal experimental setups. Methods: In six different biomechanical projects and two animal studies, we studied the capability of hamstring tendon interference fit fixation to be used as a secure and reproducible technique of anterior cruciate ligament reconstruction and compared these data to the bone-patellar tendon-bone graft and other conventional hamstring tendon graft fixation techniques. Results: We could demonstrate that the initial femoral fixation strength, as well as a hybrid fixation is sufficient. However, the tibial fixation presents the weak link and underlies different variables, such as bone density and screw geometry. Compared to conventional extra-cortical fixation techniques, the viscoelastic and viscoplastic deformation behaviour could be optimized, but did not reach comparable data to the bone-patellar tendon-bone graft. Animal experiments could clearly demonstrate that interference fit fixation promotes osseous tendon incorporation and minimises the likely hood of a tunnel enlargement. We further found that in contrast to conventional fixation techniques the use of interference screws resulted in the development of a direct ligament insertion anatomy, directly at the joint line, like it is found with the native anterior cruciate ligament. Conclusion: With the present studies we could first describe the mechanical and biological boundary conditions of hamstring tendon interference fit fixation, a technique which gains increased world wide attention as a standard procedure in cruciate ligament surgery. By using an anatomic joint line fixation of hamstring tendon grafts, there are optimised boundary conditions, which therefore presents an adequate alternative to the conventional bone-patellar tendon-bone graft in cruciate ligament reconstruction.
9

Verbundversagensmechanismen im Verankerungsbereich von textilbewehrten Feinbetonverstärkungsschichten

Ortlepp, Regine, Brückner, Anett, Lorenz, Enrico 03 June 2009 (has links) (PDF)
Experimentelle Untersuchungen an Plattenbalken zeigen, dass Querkraftverstärkungen auch außerhalb der Biegedruckzone verankert werden können. Entscheidend dabei ist, dass alle in der Verbundfuge von Altbeton und Verstärkung auftretenden Beanspruchungen durch die Haftzug- und Scherfestigkeit des Alt- und Feinbetons übertragen werden können. Ein Verbundversagen führt durch das Ablösen der Verstärkungsschicht zu deren Ausfall. Der Beitrag befasst sich mit den Beanspruchungen und Versagensmechanismen des Verankerungsbereiches, die anhand von Versuchsergebnissen dargestellt werden. Als Versagenskriterium für die Verankerung sind zwei flächige Versagensarten – der Altbetonuntergrund und die Ebene der textilen Bewehrung – zu berücksichtigen. Als weiteres Versagenskriterium der Verankerung ist der innere Verbund zwischen den Multifilamentgarnen und der sie umgebenden Feinbetonmatrix zu betrachten. Für die Bemessung des Verankerungsbereiches einer Verstärkung wird der jeweils ungünstigste Wert dieser drei Versagensarten maßgebend.
10

Verbundversagensmechanismen im Verankerungsbereich von textilbewehrten Feinbetonverstärkungsschichten

Ortlepp, Regine, Brückner, Anett, Lorenz, Enrico 03 June 2009 (has links)
Experimentelle Untersuchungen an Plattenbalken zeigen, dass Querkraftverstärkungen auch außerhalb der Biegedruckzone verankert werden können. Entscheidend dabei ist, dass alle in der Verbundfuge von Altbeton und Verstärkung auftretenden Beanspruchungen durch die Haftzug- und Scherfestigkeit des Alt- und Feinbetons übertragen werden können. Ein Verbundversagen führt durch das Ablösen der Verstärkungsschicht zu deren Ausfall. Der Beitrag befasst sich mit den Beanspruchungen und Versagensmechanismen des Verankerungsbereiches, die anhand von Versuchsergebnissen dargestellt werden. Als Versagenskriterium für die Verankerung sind zwei flächige Versagensarten – der Altbetonuntergrund und die Ebene der textilen Bewehrung – zu berücksichtigen. Als weiteres Versagenskriterium der Verankerung ist der innere Verbund zwischen den Multifilamentgarnen und der sie umgebenden Feinbetonmatrix zu betrachten. Für die Bemessung des Verankerungsbereiches einer Verstärkung wird der jeweils ungünstigste Wert dieser drei Versagensarten maßgebend.

Page generated in 0.0658 seconds